DCL-04-112, Special Report 05-02: Results of Steam Generator Tube Eddy Current Inspections During Twelfth Refueling Outage

From kanterella
(Redirected from ML050940293)
Jump to navigation Jump to search

Special Report 05-02: Results of Steam Generator Tube Eddy Current Inspections During Twelfth Refueling Outage
ML050940293
Person / Time
Site: Diablo Canyon Pacific Gas & Electric icon.png
Issue date: 03/28/2005
From: Jacobs D
Pacific Gas & Electric Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
DCL-04-112, DCL-05-028
Download: ML050940293 (95)


Text

Pacific Gas and Electric Company' Donna Jacobs Diablo Canyon Power Plant Vice President R 0. Box 56 Nuclear Services Avila Beach, CA 93424 805. 54 5.4600 March 28, 2005 Fax: 805.545.4234 PG&E Letter DCL-05-028 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket No. 50-275, OL-DPR-80 Diablo Canyon Unit 1 Special Report 05-02: Results of Steam Generator Tube Eddy Current Inspections During Unit I Twelfth Refueling Outage

Dear Commissioners and Staff:

In accordance with Diablo Canyon Power Plant Technical Specification 5.6.10.b, this special report provides the results of steam generator (SG) tube eddy current inspections performed during the Unit 1 twelfth refueling outage (1R12). SG inspections and repairs were completed in April 2004.

The enclosed tables provide the number and extent of tubes inspected in each SG, the location and percent through-wall penetration as applicable of each indication identified, and identification of tubes plugged.

PG&E letter DCL-04-112, dated September 7, 2004, provided detailed 1 R12 condition monitoring and operational assessment reports for both alternate repair criteria (ARC) and non-ARC degradation mechanisms.

Sincerely, Donrn Jacobs ddm/469 Enclosure cc/enc:

Bruce S. Mallett, Region IV David L. ProuIx, Senior Resident Inspector Girija S. Shukla, NRR State of California, Pressure Vessel Unit cc:

Diablo Distribution A member of the STARS (Strategic Teaming and Resource Sharing) AlLiance Callaway

  • Comanche Peak
  • Diablo Canyon
  • Palo Verde
  • Wolf Creek

Enclosure PG&E Letter DCL-05-028 SPECIAL REPORT 05-02 RESULTS OF STEAM GENERATOR TUBE EDDY CURRENT INSPECTIONS DURING UNIT I TWELFTH REFUELING OUTAGE

Enclosure PG&E Letter DCL-05-028 Introduction Technical Specification 5.6.1 O.b requires that the results of steam generator (SG) tube inspections be submitted to the NRC within 12 months following completion of the inspection. The report shall include:

1. Number and extent of tubes inspected,
2. Location and percent of wall thickness penetration for each indication of an imperfection, and
3. Identification of tubes plugged.

Table 1 provides the number and extent of tubes inspected in each SG. Table 2 provides the location and percent through-wall of each indication identified, and identifies the tubes that were plugged in the Unit 1 twelfth refueling outage (1R12) and reason for plugging.

PG&E letter DCL-04-112, dated September 7, 2004, provided detailed 1R12 condition monitoring and operational assessment reports for both alternate repair criteria (ARC) and non-ARC degradation mechanisms.

Abbreviations and Terms The following provides a definition of abbreviations and terms that could be used in Tables 1 and 2. Some codes may not have been used because they were not applicable in this inspection. Bobbin-distorted outside diameter support signals (DOS) at the tube support plate (TSP) intersection, and bobbin inside diameter support signals (DIS) at a dented TSP intersection that were not confirmed by Plus Point, are not reportable indications; however, they are included in this report for completeness.

Free-span indications (e.g., manufacturing burnish mark) that had eddy current signals traceable to preservice inspection data are not considered as reportable indications and are not included in this report.

Enclosure PG&E Letter DCL-05-028 Abbreviations and Terms (continued)

Abbreviation Term Description

, k SG Steam Generator (SG)

Row Row Col Column Loc Location in SG Inch Distance above or below the center line of the TSP or the top of tubesheet, inches Cal Calibration group Bobbin Differential inside diameter coil probe Plus Point Plus Point rotating probe TSP (1 H, Tube support plate. There are 7 TSPs, identified by numbered from 1C, )

bottom to top of SG followed by H (hot leg) or C (cold leg).

TSH Top of tubesheet hot leg TSC Top of tubesheet cold leg TEH Tube end hot leg ID/OD Location of indication on tube surface as characterized by Plus Point, either inside diameter (ID) or outside diameter (OD)

%TW.(TWD)

Depth of indication as percent through-wall, associated with either cold leg thinning (CLT) at cold leg TSPs, or anti vibration bar (AVB) wear in the U-bend region.

SAI Single axial indication Note: SAI may be left in service for the following reasons:

Voltage-based ARC for axial outside diameter stress corrosion cracking (ODSCC) at TSP intersections W* ARC for axial primary water stress corrosion cracking (PWSCC) in WEXTEX tubesheet

  • PWSCC ARC for axial PWSCC at dented TSP intersections SCI Single circumferential indication SVI Single volumetric indication (not associated with cold leg thinning)

VOL Volumetric indication (associated with cold leg thinning)

AONDB Axial ODSCC not detected by bobbin coil DIS Distorted ID signal at a dented TSP intersection DOS Distorted OD signal at TSP intersection FSI Free span indication DNI Ding with possible indication MBI Manufacturing burnish mark indication NDD No detectable degradation PLP Potential loose part indication PVN Permeability variation Enclosure PG&E Letter DCL-05-028 Table I Number and Extent of Tube Inspections During 1R12 Scope Probe SG 1-1 SG 1-2 SG 1-3 SG 1-4 Full length (except Rows I obn10 10 0%10 and 2 U-bends)

Bobbin 100%

100%

100%

100%

Rows 1 to 10 U-bends Plus Point 100%

100%

100%

100%

Rows 13 to 17 U-bends Plus Point 20%

20%

20%

20%

Repeat PWSCC indications Pu on 0%10 0%10 at dents and top of tubesheetPlus Point 100%

100%

100%

100%

Hot Leg top-of tubesheet Plus Point 100%

100%

100%

100%

> 5 volt dented TSP Plus Point 100% 1H to 4H 100% 1H to 7C 20% 1 H to 7H 100% 1 H to 6H intersections (Note 1) 20% 5H to 7H 20% 6C 20% 7H

> 2 and < 5 volt dented TSP Plus Point 100% 1H to 4H 100% 1H to 7C 20% 1H 100% 1H to 6H intersections (Note 1) 20% 5H 20% 6C 20% 7H

> 0.21 volt and < 2 volt Plus Point 100% 1H NA NA NA dented TSP intersections (Note 1) 20% 2H 100% of DOS 100% of DOS 100% of DOS 100% of DOS Distorted OD bobbin signals Plus Point greater than 1.4 greater than 1.4 greater than or greater than or (DOS) at TSP intersections bbivot bbinols equal to 1.7 equal to 1.7 n

.s bobbin volts bobbin volts Distorted ID bobbin signals Plus Point 100%

100%

100%

100%

(DIS) at TSP intersections Plus___

Poin____________

100

> 5 volt free span dings Plus Point 100%

100%

100%

100%

Basine Plus Point 100%

100%

100%

100%

indications I

I_

I__

Note 1: For each 20% sample, inspected at least 50 dents, or else inspected 100% if there were less than 50 dents.

Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal ID/OD Tube Status Reason for Repair 11 1

33 SAI 0.24 2H 0.03 Plus Point 70 OD 11 1

33 DOS 0.45 2H 0

bobbin 2

11 1

38 SAI 0.16 3H 0.06 Plus Point 70 OD 11 1

38 DOS 0.71 3H 0.02 bobbin 2

11 1

53 DOS

=

0.3 4H

-0.06 bobbin 2

11 1

67 DOS 1.18 2H 0.04 bobbin 5

11 2

18 DOS

=

0.31 4H

-0.02 bobbin 2

11 2

44 DOS 0.38 1 H

-0.08 bobbin 2

11 2

53 DOS 0.35 2H 0.04 bobbin 3

11 2

54 DOS 0.89 3H

.0.02 bobbin 2

11 2

55 DOS 0.3 1 H.0.02 bobbin 2

11 2

55 DOS 0.54 2H 0

bobbin 2

11 2

58 SAI 0.49 1 H

-0.07 Plus Point 69 OD 11 2

58 DOS

=

0.62 1 H

-0.07 bobbin 5

11 2

59 SAI

=

0.33 1H

-0.18 Plus Point 69 OD 11 2

59 SAI 0.35 1 H

-0.01 Plus Point 69 OD 11 2

59 DOS

=

0.27 1 H 0

bobbin 4

11 2

61 DOS 0.61 1 H

-0.07 bobbin 4

11 2

61 DOS 0.26 2H

-0.07 bobbin A

,4 11 2

62 SAI 0.21 1H

-0.21 Plus Point 92 OD 11 2

62 DOS 0.36 1H

-0.24 bobbin 4

11 2

63 DOS 0.93 1 H

-0.07 bobbin 4

11 2

64 DOS 0.66 1H

-0.22 bobbin 4

11 2

66 DOS I_

2H 0.09 bobbin 5

11 2

67 DOS

=

0.38 1H

-0.04 bobbin 4

=

11 2

71 DOS

=

0.34 2H 0.02 bobbin 4

=

11 2

92 DOS

=

0.66 2H

-0.11 bobbin 2

=

11 3

2 SAI 0.64 TSH

-1.21 Plus Point 21 ID 11 3

3 DOS

=

0.65 2H

-0.07 bobbin 4

=

11 3

22 DOS 0.66 2H

-0.02 bobbin 3

11 3

28 SAI

=

0.62 2H

-0.13 Pius Point 21 ID 11 3

28 DIS 1.12 2H

-0.15 bobbin 3

11 3

39 DOS 0.43 4H

-0.07 bobbin 2

11 3

41 SAI 0.27 1H 0.02 Plus Point 70 OD 11 3

41 DOS 0.42 1 H

-0.06 bobbin 3

11 3

45 DOS 0.96 1 H

-0.07 bobbin 3

11 3

48 DOS 0.62 1 H -0.02 bobbin 3

11 3

48 DOS

=

0.26 3H

-0.04 bobbin 3

11 3

52 DOS

=

0.26 2H 0

bobbin 3

=

11 3

52 DOS 0.42 4H

-0.04 bobbin 3

11 3

54 DOS 0.51 1 H

-0.09 bobbin 3

11 3

56 DOS 0.97 1 H

-0.07 bobbin 4

11 3

59 DOS 1.24 1 H 0

bobbin 5

11 3

60 SAI

=

0.4 1 H 0.01 Plus Point 74 OD Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal ID/OD Tube Status Reason for Repair 11 3

60 SAI 0.77 1H 0.05 Plus Point 74 OD 11 3

60 SAI 0.28 1H 0.02 Plus Point 74 OD 11 3

60 DOS 1.63 1H 0.02 bobbin 4

11 3

62 SAI 0.14 1H

-0.07 Plus Point 92 OD 11 3

63 DOS 1.15 1H

-0.11 bobbin 5

=

11 3

69 DOS 0.95 1H 0

bobbin 5

11 3

88 DOS 0.81 1H

-0.04 bobbin 3

11 4

6 PVN 11.46 5C 8.42 bobbin 13 11 4

8 DOS 0.46 1H 0

bobbin 4

11 4

20 SAI 0.17 1H

-0.07 Plus Point 92 OD 11 4

20 DOS 0.68 2H

-0.11 bobbin 2

=

11 4

24 DOS 0.43 4H

-0.07 bobbin 2

11 4

29 DOS 0.33 2H

-0.07 bobbin 3

=

11 4

31 DOS 0.26 2H

-0.09 bobbin 3

11 4

41 SAI 0.42 1H

-0.03 Plus Point 21 ID 11 4

49 DOS 0.85 1H 0.02 bobbin 2

11 4

49 DOS 0.31 3H

-0.04 bobbin 2

11 4

52 SAI 1.63 1H 0.03 Plus Point 69 OD Plugged SAI-CD, >2v DOS @ 1 H 11 4

52 DOS 2.21 1H 0

bobbin r2 Plugged SAI-D, >2v DOS @ 1H 11 4

54 SAI 0.55 1H

-0.05 Plus Point 69 OD Plugged SAI-OD, >2v DOS @ I H 11 4

54 SAI 1.58 1H 0.11 Plus Point 69 OD Plugged SAI-OD, >2v DOS @ 1H 11 4

54 DOS 2.28 1H 0.09 bobbin 2

Plugged SAI-OD, >2v DOS @ I1H 11 4

55 DOS 0.68 1H

-0.02 bobbin 2

11 4

61 SAI 0.44 1H

-0.12 Plus Point 74 OD 11 4

61 SAI 0.56 1H

-0.04 Plus Point 74 OD 11 4

61 SAI 3.13 TEH 1.86 Plus Point 58 ID 11 4

61 SAI 2.36 TEH 1.85 Plus Point 58 ID.

11 4

61 SAI 2.29 TEH 2.05 Plus Point 58 ID 11 4

61 SAI 3.91 TEH 1.68 Plus Point 58 ID 11 4

61 SAI 3.37 TEH 2.09 Plus Point 58 ID 11 4

61 SAI 2.63 TEH 2.08 Plus Point 58 ID 11 4

61 SAI 1.29 TEH 1.84 Plus Point 58 ID 11 4

61 SAI 3.3 TEH 1.26 Plus Point 58 ID 11 4

61 DOS 1.42 1H

-0.06 bobbin 4

11 4

63 DOS 0.37 1H 0

bobbin 4

=

11 4

64 SAI 0.43 1H

-0.11 Plus Point 69 OD Plugged SAI-CD, >2v DOS @ 1H 11 4

64 SAI 1.37 1H

-0.04 Plus Point 69 OD Plugged SAI-CD, >2v DOS @ I H 11 4

64 DOS 2.09 11H -0.09 bobbin 4

Plugged SAI-OD, >2v DOS @ 1 H 11 4

69 DOS 1.24 1H

-0.16 bobbin 4

11 4

80 DOS 1.16 1H 0.07 bobbin 5

11 4

92 TWD 5

0.31 1C 0.07 bobbin 17 11 4

92 TWD 37 2.88 2C

-0.04 bobbin 17 11 4

93 VOL 0.09 1C

-0.04 Plus Point 66 OD 11 4

93 TWD 4

0.21 1C

-0.06 bobbin 18

=

Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 11 4

94 TWD 17 1.1 2C 0.11 bobbin 18 11 5

2 SAI 0.15 1H

-0.05 Plus Point 71 OD 11 5

2 SAI 0.12 1H

-0.02 Plus Point 71 OD 11 5

2 DOS 0.32 1H 0

bobbin 4

11 5

2 DIS 1.09 5H

-0.02 bobbin 4

11 5

4 DOS 0.27 1H 0.02 bobbin 4

11 5

6 SAI 0.17 1H

-0.06 Plus Point 71 OD Plugged SAI-OD @ 2H Wedge 11 5

6 SAI 0.17 1H

-0.06 Plus Point 71 OD Plugged SAI-OD @ 2H Wedge 11 5

6 SAI 0.15 2H

-0.07 Plus Point 71 OD Plugged SAI-OD @ 2H Wedge 11 5

6 SAI 0.12 2H

-0.06 Plus Point 71 OD Plugged SAI-OD @ 2H Wedge 11 5

6 DOS 0.89 1 H 0.02 bobbin 4

Plugged SAI-OD @ 2H Wedge 11 5

6 DOS 0.35 2H

-0.07 bobbin 4

Plumed SAI-OD @ 2H Wedge 11 5

10 DIS 1.23 2H 0.06 bobbin 4

11 5

12 DOS I 0.69 2H

-0.07 bobbin 4

11 5

20 DOS 0.4 1H

-0.02 bobbin 3

11 5

34 SAI 0.19 1H 0.05 Plus Point 92 OD 11 5

35 DOS 0.84 1H 1-0.07 bobbin 3

=

11 5

38 DOS 0.33 3H

-0.07 bobbin 3

11 5

39 DOS I 0.63 3H

-0.11 bobbin 3

11 5

43 SAI 0.74 1H

-0.07 Plus Point 71 OD 11 5

43 DOS 1.21 1H

-0.07 bobbin 3

11 5

49 DOS 0.99 2H

-0.02 bobbin 3

11 5

51 DOS 0.25 3H 0.02 bobbin 3 1 11 5

53 DOS 1.04 1H 0

bobbin 3

11 5

54 DOS 1.05 1H

-0.07 bobbin 3

=

11 5

59 SAI 3.29 TEH 1.86 Plus Point 58 ID 11 5

59 SAI 2.45 TEH 1 1.74 Plus Point 58 ID 11 5

59 SAI 2.15 TEH 2

Plus Point 58 ID 11 5

59 SAI 1.82 TEH 1.93 Plus Point 58 ID 11 5

59 SAI 0.62 TEH 1.89 Plus Point 58 ID 11 5

59 SAI 3.11 TEH 2.16 Plus Point 58 ID 11 5

59 SAI 2.92 TEH 1.7 Plus Point 58 ID 11 5

59 DOS 1.11 1H 0.05 bobbin 4

=

11 5

59 DOS 0.55 2H

-0.16 bobbin 4

11 5

60 SAI 0.92 1H

-0.02 Plus Point 21 OD Plugged SAI-OD, >2v DOS @ IH 11 5

60 SAI 2.85 1H 0.02 Plus Point 21 OD Plugged SAI-OD, >2v DOS @ IH 11 5

60 SAI 1.19 1H

-0.06 Plus Point 21 OD Plugged SAI-OD, >2v DOS @ IH 11 5

60 DOS 6.15 1H

-0.02 bobbin 4

Plugged SAI-OD, >2v DOS a IH 11 5

61 DOS 0.32 1H 0.07 bobbin 4

11 5

63 DOS 0.73 1H 0.11 bobbin 5

=

11 5

64 SAI 3.12 TEH 1.78 Plus Point 58 ID 11 5

64 SAI 2.9 TEH 1.44 Plus Point 58 ID 11 5

64 SAI 1.25 TEH 2.08 Plus Point 58 ID 11 5

64 SAI 1.23 TEH 1.28 Plus Point 58 ID Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 11 5

64 SAI

=

3.39 TEH 1.7 Plus Point 58 ID 11 5

64 SAI

=

2.02 TEH 1.73 Plus Point 58 ID 11 5

64 SAI

=

2.14 TEH 1.17 Plus Point 58 ID 11 5

64 SAI

=

3.35 TEH 1.81 Plus Point 58 ID 11 5

64 DOS 0.72 1H

-0.13 bobbin 4

11 5

66 SAI 1.31 11H

-0.03 Plus Point 69 OD 11 5

66 DOS 1.88 1 H

-0.07 bobbin 4

11 5

66 DOS 0.24 2H

-0.02 bobbin 4

11 5

67 DOS = 0.35 1 H

-0.02 bobbin 4

=

11 5

68 DOS = 1.13 1 H 0.05 bobbin 4

11 5

69 DOS 1

H -0.16 bobbin 4

11 5

71 DOS _

0.31 1H

-0.04 bobbin 4

=

11 5

72 SAI

=

0.6 1 H

-0.18 Plus Point 74 OD 11 5

72 SAI 0.75 1 H

-0.23 Plus Point 74 OD 11 5

72 SAI _

0.16 1H

-0.09 Plus Point 74 OD 11 5

72 SAI 0.48 1 H 0.01 Plus Point 74 OD 11 5

72 DOS = 1.42 1H

-0.24 bobbin 4

=

11 5

72 DOS.

0.48 2H 0

bobbin 4

11 5

76 DOS 0.83 1H 0.07 bobbin 4

11 5

82 DOS = 1.35 1H

-0.09 bobbin 4

=

11 5

83 DOS = 0.58 1H 0.02 bobbin 4

=

11 5

94 VOL

=

0.2 2C 0.05 Plus Point 66 OD 11 5

94 TWD 13 0.83 1C

-0.02 bobbin 17

=

11 5

94 TWD 15 0.95 2C 0.11 bobbin 17

=

11 6

15 DOS 0.54 1H 0.13 bobbin 36

=

11 6

25 DOS = 0.68 2H 0.02 bobbin 38

=

11 6

27 DOS 0.55 1 H

-0.04 bobbin 38 11 6

31 SAI 0.37 1 H 0

Plus Point 70 OD 11 6

31 DOS 0.98 1H 0.04 bobbin 38

=

11 6

32 DOS _

0.4 2H 0.02 bobbin 38 11 6

33 SAI 0.14 4H 0.14 Plus Point 70 OD 11 6

33 DOS 0.42 4H 0.04 bobbin 37 11 6

39 SCI 0.8 TSH -0.05 Plus Point 37 ID Plugged SC-ID @ TSH 11 6

39 DOS 0.69 3H 0.04 bobbin 42 Plugged SCI-ID @ TSH 11 6

40 SAI 0.16 1H

-0.03 Plus Point 70 OD 11 6

40 DOS 0.32 1H

-0.04 bobbin 42

=

11 6

41 DOS

=

0.56 1H 0.1 bobbin 39 9 11 6

43 DOS 0.64 1 H 0

bobbin 40.

11 6

44 DOS.

0.2 2H 0.09 bobbin 40.

11 6

61 SAI 2.94 1H 0.17 Plus Point 44 OD Plugged SAI-OD, >2v DOS @ 1H 11 6

61 SAI I__

0.68 1H 0.13 Plus Point 44 OD Plugged SAI-OD, >2v DOS @ IH 11 6

61 SAI

=

0.37 1H 0.15 Plus Point 44 OD Plugged SAI-OD, >2v DOS @ 1H 11 6

61 DOS 5.6 1H 0.06 bobbin 41

=

Plugged SAI-OD. >2v DOS @ 1H 11 6

62 DOS = 0.69 1 H

-0.04 bobbin 24

=

Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 11 6

68 DOS 0.6 1H 0

bobbin 24 11 6

71 DOS 0.79 1H

-0.02 bobbin 24 11 6

73 DOS 0.93 1H 0.06 bobbin 41 11 6

74 DOS

=

0.24 1H

-0.09 bobbin 41 11 6

76 DOS

=

0.82 1H 0.04 bobbin 28

=

11 6

78 SAI 0.31 2H 0.01 Plus Point 44 OD Plugged SAI-OD, >2v DOS @ 2H 11 6

78 SAI 2.24 2H 0

Plus Point 44 OD Plugged SAI-OD, >2v DOS > 2H 11 6

78 SAI 0.31 2H

-0.05 Plus Point 44 OD Plugged SAI-D, >2v DOS @ 2H 11 6

78 DOS 0.3 1 H 0

bobbin 28 Plugged SAI-OD, >2v DOS > 2H 11 6

78 DOS 3.04 2H 0.04 bobbin 28 Plugged SAI-OD, >2v DOS } 2H 11 6

86 DOS 0.61 2H 0.06 bobbin 30 11 6

88 DOS

=

0.19 2H 0.09 bobbin 30 11 6

92 DOS

=

0.21 2H 0.06 bobbin 30

=

11 6

93 TWD 12 0.76 1C 0.13 bobbin 30 11 7

10 SAI 0.15 1H

-0.01 Plus Point 71 OD 11 7

10 DOS 0.42 1H 0.02 bobbin 33 11 7

12 DOS 0.18 1H 0.06 bobbin 35 11 7

18 DOS 0.25 2H 0.02 bobbin 35 11 7

27 DOS 0.37 1H

-0.04 bobbin 37 11 7

28 DOS _I_

0.3 11H 0.11 bobbin ' 37 11 7

28 DOS 0.41 2H 0.11 bobbin 37 11 7

31 DOS 0.77 11H 0

bobbin 37 11 7

37 SAI

=

0.36 3H

-0.13 Plus Point 70 OD 11 7

37 DOS

=

1.07 3H

-0.06 bobbin 41

=

11 7

39 DOS

=

0.94 1 H 0

bobbin 41

=__

11 7

49 DOS

=

0.61 6H

-0.28 bobbin 40

=

11 7

56 DOS.

0.51 2C

-0.09 bobbin 23 11 7

57 DOS 0.35 3H 0.02 bobbin 23 11 7

62 DOS.

0.8 1 H

-0.02 bobbin 23.

11 7

63 DOS.

0.55 1 H 0.09 bobbin 41 11 7

73 DOS 0.47 1 H 0.02 bobbin 26 11 7

77 DOS 0.98 2H 0.15 bobbin 28 11 7

78 DOS 0.72 2H 0.09 bobbin 26 11 7

81 DOS 0.53 2H 0.09 bobbin 28 11 7

82 SAI 0.67 1 H 0

Plus Point 92 OD 11 7

82 DOS 1

1 H 0

bobbin 28 11 7

85 SAI

=

0.24 1H 0

Plus Point 92 OD 11 7

85 DOS

=

0.35 1 H 0.11 bobbin 29

=

11 8

2 TWD 6

0.35 2C

-0.11 bobbin 34 11 8

11 SAI 0.14 1H 0.09 Plus Point 92 OD 11 8

11 DOS 0.24 1H 0.02 bobbin 34 11 8

24 SAI 0.09 2H 0

Plus Point 71 OD 11 8

24 SAI 0.12 2H 0.01 Plus Point 71 OD 11 8

24 DOS

=

0.36 2H 0.06 bobbin 38

=

Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During IR12 SG Row Col Ind

%TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair I1 8

31 DOS 0.31 3H

-0.02 bobbin 38 1 _

l I

I 11 8

32 SAI 0.15 3H 0.05 Plus Point 70 OD 11 8

42 SAI 0.23 1H

-0.06 Plus Point 71 OD 11 8

42 SAI 0.11 1H

-0.1 Plus Point 71 OD 11 8

42 DOS 0.44 11H 0.08 bobbin 40 11 8

57 DOS 1.31 1 H 0.02 bobbin 24 11 8

58 DOS 1.07 1 H 0.15 bobbin 24 11 8

59 DOS 0.25 2H 0.04 bobbin 24 11 8

64 DOS 0.51 1 H 0.17 bobbin 24 11 8

69 SAI 0.14 1H 0.02 Plus Point 44 OD Plugged SAl-OD, >2v DOS @ IH 11 8

69 SAI 0.35 1 H 0

Plus Point 44 OD Plugged SAI-OD, >2v DOS @ I H 11 8

69 SAI 0.23 1H

.0.04 Plus Point 44 OD Plugged SAI-OD, >2v DOS @ H 11 8

69 SAI 2.29 1H 0.01 Plus Point 44 OD Plugged SAI-OD, >2v DOS @ I H 11 8

69 DOS 3.4 1

H 0.06 bobbin 41 Plugged SAI-OD, >2v DOS @ 1 H 11 8

71 SAI 0.46 11H -0.06 Plus Point 69 OD Plugged SAI-OD, >2v DOS @ 1H 11 8

71 SAI 0.58 1 H

-0.01 Plus Point 69 OD Plugged SAI-OD, >2v DOS @ 1H 11 8

71 SAI 0.32 1H 0

Plus Point 69 OD Plugged SAI-OD, >2v DOS @ 1H 11 8

71 DOS 2.07 1H 0.06 bobbin 51 Plugged SAI-OD, >2vDOS IH 11 8

72 SAI 2.67 1H

-0.06 Plus Point 44 OD Plugged SAI-OD, >2v DOS @ IH 11 8

72 SAI 1.89 1 H

-0.06 Plus Point 44 OD Plugged SAI-OD, >2v DOS @ 1 H 11 8

72 DOS 5.06 1H 0

bobbin 41 Plugged SAI-OD, >2v DOS @ IH 11 8

77 DOS 0.28 2H 0.07 bobbin 26 11 8

81 DOS 0.51 2H

-0.02 bobbin 26 11 8

90 SAI 0.52 1 H

-0.11 Plus Point 69 OD Plugged SAI-OD @ 1 H Wedge 11 8

90 DOS 0.63 1 H 0.02 bobbin 30 Plugged SAI-OD @ I H Wedge 11 9

3 SAI 0.18 2H 0

Pius Point 71 OD Plugged SAI-OD @ 2H Wedge 11 9

3 DOS 0.64 1 H 0

bobbin 51 Plugged SAI-OD @ 2H Wedge 11 9

17 DOS 0.59 2H

-0.07 bobbin 3

11 9

20 DOS 0.48 1 H 0.04 bobbin 51 11 9

20 DOS 0.57 2H

-0.13 bobbin 51 11 9

43 DOS 0.4 2H 0

bobbin 40 11 9

47 DOS 0.34 2H 0.04 bobbin 40 11 9

48 DOS 0.23 2H 0.02 bobbin 39

=

11 9

54 DOS 0.19 11H 0.02 bobbin 23 11 9

56 DOS 0.24 2C

-0.02 bobbin 23

=

11 9

57 DOS 0.31 1 H 0.04 bobbin 23 11 9

67 DOS 1.34 1 H

-0.09 bobbin 23 11 9

69 DOS 0.37 2H 0.06 bobbin 23

=

11 9

82 SAI 0.46 1 H 0

Plus Point 92 OD 11 9

82 DOS 0.91 1 H 0

bobbin 28 11 9

92 TWD 11 0.71 1 C -0.15 bobbin 29

=

11 9

93 TWD 5

0.3 1 C

-0.26 bobbin 29 11 10 10 DOS 0.2 1H 0.09 bobbin 34 11 10 15 DOS 0.34 2H 0

bobbin 32 Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal ID/OD Tube Status Reason for Repair 11 10 23 DOS 0.57 2H 0.09 bobbin 35 11 10 23 DOS 0.59 3H

-0.04 bobbin 35 11 10 28 SAI 0.15 1 H 0.04 Plus Point 70 OD 11 10 28 DOS 0.09 1 H 0.08 bobbin 38

=

11 10 28 DOS 0.5 2H 0.11 bobbin 38 11 10 39 SAI 0.73 1H 0.04 Plus Point 70 OD 11 10 39 SAI 0.21 2H

-0.02 Plus Point 70 OD 11 10 39 DOS 1.03 1H 0.08 bobbin 42 11 10 39 DOS 0.39 2H 0.02 bobbin 42 11 10 45 DIS 0.79 2H 0.04 bobbin 40 11 10 68 SAI 0.67 1H

-0.08 Plus Point 74 OD 11 10 68 SAI 0.39 IH 0.11 Plus Point 74-OD 11 10 68 DOS 1.43 IH

-0.15 bobbin 24

=

11 10 70 DOS 0.33 3H

-0.13 bobbin 24 11 10 71 SAI 1.47 1H

-0.11 Plus Point 69 OD Plugged SAI-OD, >2v DOSR 1 H 11 10 71 DOS 2.28 IH

-0.04 bobbin 51 Pluged SAl-CD >2v DOS @ IH 11 10 74 DOS 0.87 1H 0.07 bobbin 26

=

99 11 10 76 DOS 1.29 1H 0.15 bobbin 28

=

11 10 81 IDOS 035 1 IH 0.02 bobbin I 26 11 10 85 SAI 0.27 IH 0

Plus Point 92 OD 11 10 85 DOS 0.3 IH 0.11 bobbin 30 11

.10 92 TWD 8

0.47 IC

-0.26 bobbin 30 11 10 93 TWD 16 1.02 IC

-0.28 bobbin 30 11 11 8

DOS 0.33 1 H 0.04 bobbin 34 11 11 15 SAI 0.23 3H

-0.26 Plus Point 41 OD 11 11 22 SAI 0.12 2H

-0.2 Plus Point 71 OD 11 11 22 SAI 0.15 2H 0.05 Plus Point 71 OD 11 11 22 DOS 0.38 2H 0.02 bobbin 35 11 11 29 DOS 0.51 2H

-0.11 bobbin 37 11 11 38 DOS 0.31 1 H 0.04 bobbin 41

=

11 11 40 SAI

=

0.23 2H

.0.08 Plus Point 71 OD 11 11 40 DOS.

1.16 2H 0.06 bobbin 42 11 11 43 DOS 0.27 1 H 0.06 bobbin 39 11 11 53 DOS 0.52 1 H

-0.07 bobbin 23 11 11 53 DOS 0.36 3H 0.04 bobbin 23 11 11 58 SAI 4.3 TEH 1.02 Plus Point 45 ID 11 11 58 SAI

=

2.07 TEH 1.71 Plus Point 45 ID 11 11 58 SAI 1.19 TEH 1.69 Plus Point 45 ID 11 11 58 SAI

=

1.17 TEH 1.02 Plus Point 45 ID 11 11 58 SAI _

2.96 TEH 1.31 Plus Point 45 ID 11 11 58 SAI 3.46 TEH 1.19 Plus Point 45 ID 11 11 58 SAI.

2.99 TEH 0.95 Plus Point 45 ID 11 11 58 SAI 0.92 TEH 0.8 Plus Point 45 ID 11 11 58 SAI 0.87 TEH 1.02 Plus Point 45 ID Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 11 11 58 DOS 1.09 1H 0.09 bobbin 41 11 11 58 DOS 0.43 2H 0.09 bobbin 41 11 11 59 DOS 0.88 1H 0.04 bobbin 23 11 11 60 DOS

=

0.25 1H

-0.04 bobbin 23 11 11 60 DOS

=

0.32 3H 0.02 bobbin 23

=

11 11 62 DOS 0.42 1H

-0.04 bobbin 23 11 11 62 DOS 0.97 2H 0.04 bobbin 23 11 11 64 DOS 0.5 1H 0.19 bobbin 41 11 11 65 DOS 1.2 1H 0.11 bobbin 23 11 11 68 DOS 0.82 1 H 0.07 bobbin 23 11 11 77 DOS 0.57 2H 0

bobbin 28 11 11 80 DOS

=

0.39 1H 0.04 bobbin 28

=

11 11 93 TWD 10 0.65 1C

-0.21 bobbin 29 11 12 2

DOS 0.87 1H 0.09 bobbin 33

=

11 12 13 DOS 0.37 1H 0

bobbin 35

=

11 12 27 DOS

=

0.31 2H 0.17 bobbin 38

=

11 12 63 SAI 0.1 2H

-0.07 Plus Point 69 OD 11 12 63 DOS 0.46 2H

-0.26 bobbin 24 11 12 67 DOS 1.27 1H

-0.04 tbobbin 24,

11 12 67 DOS 0.77 3H 0.02

'bobbin 24 11 12 70 SAI 1.1 1H

-0.04 Plus Point 74 OD 11 12 70 SAI 0.37 1H 0

Plus Point 74 OD 11 12 70 SAI 0.45 1H 0.1 Plus Point 74 OD 11 12 70 DOS

=

1.5 1H 0.13 bobbin 51

=

11 12 71 SAI 1.63 1H -0.03 Plus Point 44 OD Plugged SAI-OD, >2v DOS @ 1H 11 12 71 SAI 0.29 1H

-0.13 Plus Point 44 OD Plugged SAI-OD, >2v DOS @ 1H 11 12 71 SAI 0.29 1H

-0.17 Plus Point 44 OD Plugged SAI-OD, >2v DOS @ 1H 11 12 71 SAI 0.69 1H

-0.07 Plus Point 44 OD Plugged SAI-OD, >2v DOS @ IH 11 12 71 SAI 0.3 1H 0

Plus Point 44 OD Plugged SAI-OD, >2v DOS @ IH 11 12 71 DOS 3.05 1H 0

bobbin 51 Plugged SAI-OD, >2v DOS @ 1H 11 12 73 DOS 0.55 1H 0.02 bobbin 26 11 12 74 DOS 1.03 2H

-0.02 bobbin 26 11 12 76 DOS 0.45 1H 0.15 bobbin 28 11 12 78 DOS 0.39 2H 0.11 bobbin 28 11 12 86 SAI

=

0.65 1H

-0.09 Plus Point 69 OD Plugged SAI-OD @ 1 H Wedge 11 12 86 DOS 1

1 H 0.02 bobbin 30 Plugged SAI-OD @ I H Wedge 11 12 91 TWD 15 0.99 1C -0.19 bobbin 30 11 13 14 DOS 0.49 2H 0.09 bobbin 35 11 13 22 DOS 0.2 4H 0

bobbin 35

=

11 13 23 DOS

=

0.58 1H

-0.04 bobbin 35

=

11 13 24 DOS 0.5 1H

-0.11 bobbin 37 11 13 24 DOS 0.39 3H 0.13 bobbin 37 11 13 26 DOS

=

0.3 1H 0.13 bobbin 31

=

11 13 32 DOS 0.74 2H 0.02 bobbin 37.

- 1 1 -

Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind

%TW Volts Loc Inch Probe Cal ID/OD Tube Status Reason for Repair 11 13 41 SAI 0.15 2H 0.17 Plus Point 93 OD 11 13 41 DOS 0.83 4H 0.06 bobbin 39 11 13 44 SAI 0.11 2H

-0.04 Plus Point 71 OD 11 13 44 DOS 0.35 2H 0.09 bobbin 39 11 13 44 DOS 0.41 3H 0

bobbin 39 11 13 52 DOS 0.7 2H

.0.11 bobbin 23

=

11 13 53 DOS 0.28 1 H 0.04 bobbin 23 11 13 56 DOS 0.75 1 H 0.13 bobbin 23 11 13 58 DOS 0.63 1H 0.04 bobbin 23 11 13 59 DOS 0.57 1H 0.15 bobbin 23 11 13 61 DOS 0.64 1 H 0

bobbin 23 11 13 67 SAI 0.44 1H

-0.09 Plus Point 69 OD Plugged SAI-OD, >2v DOS @ IH 11 13 67 SAI

=

0.7 1H

-0.07 Plus Point 69 OD Plugged SAI-OD, >2v DOS @ I1H 11 13 67 SAI

=

1.27 1H

-0.02 Plus Point 69 OD Plugged SAI-OD, >2v DOS c I1H 11 13 67 DOS 2.61 11H 0.02 bobbin 23 Plugged SAI-OD, >2v DOS @ 1H 11 13 77 DOS I 0.91 1 H 0

bobbin 28 11 13 77 DOS 0.58 2H

-0.04 bobbin 28 11 13 81 DOS 1.32 1H 0

bobbin 28 11 13 81 DOS 0.4 2H

-0.07 bobbin 28 11 14 13 SAI 0.27 TEH 1.75 Plus Point 34 ID 11 14 13 SAI 0.89 TEH 2.25 Plus Point 34 ID 11 14 13 SAI 0.63 TEH 2

Plus Point 34 ID 11 14 13 SAI 0.56 TEH 1.77 Plus Point 34 ID 11 14 13 SAI 0.39 TEH 1.06 Plus Point 34 ID 11 14 13 SAI _

0.68 TEH 1.26 Plus Point 34 ID 11 14 13 SAI

=

0.69 TEH 1.47 Plus Point 34 ID 11 14 13 DOS 0.69 1H

-0.13 bobbin 14

=

11 14 24 SAI 0.16 2H 0.07 Plus Point 92 OD 11 14 24 DOS 0.26 2H 0.11 bobbin 14 11 14 25 DOS 0.74 1H

-0.14 bobbin 14 11 14 26 SAI 0.14 2H 0.15 Plus Point 70 OD 11 14 26 DOS 0.4 2H 0.04 bobbin 14 11 14 28 SAI 0.42 2H 0.22 Plus Point 21 ID 11 14 51 SCI 0.22 TSH 0.08 Plus Point 50 OD Plugged SCI-OD @ TSH 11 14 52 DOS 0.24 1 H 0

bobbin 31 11 14 54 DOS 1.11 1 H 0.02 bobbin 30 11 14 55 DOS

=

0.27 2H 0.06 bobbin 30

=

11 14 59 DOS 0.37 1H 0

bobbin 30 11 14 62 SAI 0.13 2H

-0.04 Plus Point 46 OD I 11 14 62 DOS.

0.4 1H 0

bobbin 32.

11 14 62 DOS 0.28 2H 0.09 bobbin 32 11 14 77 DOS 0.46 1 H 0

bobbin 18 11 14 78 DOS 0.86 1 H 0

bobbin 18

=

11 14 80 SAI 0.18 1H

-0.05 Plus Point 69 OD Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind

%TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 11 14 80 SAI 0.76 1H 0.04 Plus Point 69 OD 11 14 80 SAI 0.34 1H 0.04 Plus Point 69 OD 11 14 80 DOS 1.7 1H 0.13 bobbin 31 11 14 83 SAI 0.44 1H

-0.11 Plus Point 50 OD 11 14 83 SAI 0.22 2H

-0.06 Plus Pointl 50 OD 11 14 83 DOS 0.79 1H

-0.19 bobbin 18 11 14 83 DOS

=

0.53 2H

-0.13 bobbin 18

=

11 14 88 SAI 0.43 1H

-0.03 Plus Point 69 OD 11 14 88 DOS 0.75 1 H

-0.04 bobbin 18 11 15 10 SAI I

I TSH -8.19 Plus Point 21 ID 11 15 10 SAI 0.71 TSH -9.05 Plus Point 21 ID 11 15 16 SAI 0.41 2H

-0.07 Plus Point 21 ID 11 15 24 DOS 0.66 1 H

-0.07 bobbin 13 11 15 24 DOS 0.77 2H

-0.07 bobbin 13 11 15 30 SAI _

0.32 2H

-0.1 Plus Point 70 OD 11 15 30 DOS

=

0.79 2H

-0.18 bobbin 13

=

11 15 31 DOS 0.82 2H

-0.24

- bobbin 15 11 15 42 DOS.

0.5 1H 0

bobbin 16 11 15 61 SAI 0.18 1H 0.07 Plus Point 69 OD 11 15 61 DOS

=

0.38 1H 0.17 bobbin 31 11 15 63 DOS 0.3 1H 0.11 bobbin 32 11 15 65 DOS 1.24 1H

-0.04 bobbin 17 11 15 66 DOS 0.36 1H

-0.07 bobbin 17 11 15 68 DOS 0.58 1 H

-0.02 bobbin 18.

11 15 75 DOS 0.38 1 H

-0.06 bobbin 17 11 15 76 SAI 0.46 2H

-0.1 Plus Point 21 ID 11 15 76 SAI 2.36 TEH 0.67 Plus Point 45 ID 11 15 76 DOS 0.16 2H

-0.06 bobbin 17 11 15 77 DOS I

-_ 0.26 1 H 0

bobbin 17 11 15 80 DOS 0.51 1 H

-0.06 bobbin 17 11 15 82 DOS 0.71 1H

-0.13 bobbin 17

=

11 15 88 DOS 0.5 2H

-0.06 bobbin 17 11 15 92 TWD 8

0.48 1C

-0.07 bobbin 17 11 16 27 DOS _

0.33 1 H

-0.02 bobbin 14 11 16 27 DOS 1.15 2H

-0.11 bobbin 14 11 16 57 DOS 0.34 2H 0

bobbin 29 11 16 60 DOS 0.38 1H 0.06 bobbin 29 11 16 62 DOS 0.35 1H 0

bobbin 32 11 16 64 DOS

=

0.39 1 H 0.11 bobbin 32 11 16 66 DOS.

0.46 1 H

-0.06 bobbin 18 11 16 68 SAI 0.58 TEH 1.67 Plus Point 45 ID 11 16 68 SAI 0.68 TEH 1.39 Plus Point 45 ID 11 16 68 SAI _

0.59 TEH 1.5 Plus Point 45 ID 11 16 68 SAI

=

0.76 TEH 1.38 Plus Point 45 ID Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 11 16 68 SAI 0.89 TEH I

Plus Point 45 ID 11 16 68 SAI 0.93 TEH 1.1 Plus Point 45 ID 11 16 68 SAI 1.9 TEH 0.79 Plus Point 45 ID 11 16 68 SAI

=

1.44 TEH 0.79 Plus Point 45 ID 11 16 68 SAI 1.34 TEH 0.84 Plus Point 45 ID 11 16 68 SAI

=

3.15 TEH 0.84 Plus Point 45 ID 11 16 68 SAI 3.99 TEH 0.77 Plus Point 45 ID 11 16 68 SAI 3.03 TEH 0.78 Plus Point 45 ID 11 16 68 SAI 1.12 TEH 0.87 Plus Point 45 ID 11 16 68 SAI 0.62 TEH 1.01 Plus Point 45 ID 11 16 68 DOS 0.31 1H -0.02 bobbin 17 11 16 70 SAI 0.98 TEH 1.39 Plus Point 45 ID 11 16 70 SAI 2.06 TEH 1.72 Plus Point 45 ID 11 16 70 SAI

=

2.07 TEH 1.73 Plus Point 45 ID 11 16 70 SAI

=

1.77 TEH 1.82 Plus Point 45 ID 11 16 70 SAI 2.45 TEH 1.71 Plus Point 45 ID 11 16 70 SAI 2

TEH 1.53 Plus Point 45 ID 11 16 70 SAI 1.52 TEH 1.25 Plus Point 45 ID 11 16 70 SAI 0.93 TEH 1.54 Plus Point 45 ID 11 16 70 DOS I 0.48 1H -0.02 bobbin 18 11 16 79 SAI 0.2 2H

-0.15 Plus Point 47 OD 11 16 79 DOS 0.6 2H

-0.09 bobbin 18 11 16 80 DOS

_ 0.56 2H

-0.04 bobbin 18 11 16 82 DOS 0.28 1H 0

bobbin 18 11 16 83 DOS

= 0.25 3H 0

bobbin 18 11 17 16 SAI

=

0.95 2H

-0.12 Plus Point 71 ID 11 17 16 DIS

=

0.51 2H

-0.11 bobbin 13

=

11 17 27 SAI

=

0.28 3H 0.07 PIus Point 53 OD 11 17 27 DIS 0.47 1H 0

bobbin 13

=

11 17 30 DOS

0.29 1H 0.02 bobbin 13

11 17 35 TWD 14 0.31 7H 34.4 bobbin 15 11 17 41 DOS 0.47 1H 0

bobbin 15 11 17 42 DOS 0.25 2H 0

bobbin 39 11 17 45 DOS 1.02 1H -0.02 bobbin 16 11 17 49 DOS 0.34 1H -0.02 bobbin 15 11 17 50 DOS 0.1 3H 0.06 bobbin 29 11 17 51 DOS 0.32 1H 0.02 bobbin 29 11 17 53 DOS

= 0.52 1H 0.09 bobbin 30

=

11 17 56 SAI

=

1.26 1H 0

Plus Point 74 OD 11 17 56 DOS 1.47 1H 0.06 bobbin 29 11 17 56 DOS 0.61 2H

-0.02 bobbin 29 11 17 62 SCI 0.29 TSH -0.03 Plus Point 45 OD Plugged SC-OD @ TSH 11 17 62 DOS 0.34 1H 0.04 bobbin 31.

1 Plugged SCI-OD @ TSH 11 17 62 DOS 0.29 2H

-0.04 bobbin 31

_1 Plugged SCI-OD @ TSH Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During IR12 SG Row Col Ind %1W Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 11 17 66 DOS 1.06 1H 0.02 bobbin

.17 11 17 67 DOS 0.57 1 H 0.13 bobbin 17 11 17 73 SAI 0.31 1H 0.04 Plus Point 26 OD Plugged SAI-OD, >2v DOS @ 1H 11 17 73 SAI I=_

1.32 1H

-0.05 Plus Point 26 OD Plugged SAI-OD, >2v DOS @ 1H 11 17 73 SAI 0.14 1H 0.06 Plus Point 26 OD Plugged SAI-OD, >2v DOS @ 1H 11 17 73 SAI.

0.25 1H 0.11 Plus Point 26 OD Plugged SAI-OD, >2v DOS @ 1H 11 17 73 SAI 1.55 1H 0.06 Plus Point 26 OD Plugged SAI-OD, >2v DOS @ 1H 11 17 73 DOS 4.01 1H 0.02 bobbin 31 _

Plugged SAI-OD, >2v DOS @ 1H 11 17 73 DIS 0.81 3H

-0.06 bobbin 17 Plugged SAI-OD, >2v DOS @ 1H 11 17 74 SAI 0.29 1H

-0.14 Plus Point 69 OD 11 17 74 SAI 1.09 1H

-0.13 Plus Point 69 OD 11 17 74 DOS

=

1.9 I H

-0.02 bobbin 31

=

11 17 74 DOS 0.28 3H

-0.15 bobbin 31 11 17 74 TWD 15 0.34 7H 33.66 bobbin 17 11 17 75 DOS _

0.95 2H 0

bobbin 17 11 17 76 SAI 0.25 1H

-0.18 Plus Point 69 OD 11 17 76 SAI 3.15 TEH 0.79 Plus Point 45 ID I

11 17 76 SAI 2.52 TEH 0.79 Plus Point 45 ID 11 17 76 SAl 1.13 TEH 0.79 Plus Point 45 ID 11 17 76 SAI 1.02 TEH 1.54 Plus Point 45 ID 11 17 76 SAI 1.85 TEH 1.5 Plus Point 45 ID 11 17 76 SAI 0.96 TEH 1.46 Plus Point 45 ID 11 17 76 SAI 0.53 TEH 1.42 Plus Point 45 ID 11 17 76 SAI.

2.26 TEH 1.41 Plus Point 45 ID 11 17 76 SAI

=

1.75 TEH 1.03 Plus Point 45 ID 11 17 76 SAI 3.85 TEH 0.76 Plus Point 45 ID 11 17 76 SAI 4.61 TEH 0.76 Plus Point 45 ID 11 17 76 SAI 2.19 TEH 0.76 Plus Point 45 ID 11 17 76 SAI 4.23 TEH 0.75 Plus Point 45 ID 11 17 76 SAI 4.52 TEH 0.75 Plus Point 45 ID 11 17 76 DOS 0.82 1 H

-0.28 bobbin 17 11 17 77 SAI _

0.99 1H

-0.02 Plus Point 69 OD Plugged SAI-OD, >2v DOS @ 1H 11 17 77 SAI 0.78 1H

-0.06 Plus Point 69 OD Plugged SAI-OD, >2v DOS @ 1H 11 17 77 SAI 0.45 1H

-0.06 Plus Point 69 OD Plugged SAI-OD, >2v DOS @ 1H 11 17 77 DOS 2.27 1H 0.04 bobbin 31 Plu ed SAI-OD, >2v DOS 1H 11 17 78 DOS

=

0.25 1H

-0.06 bobbin 17

=

99 11 17 80 DOS 0.42 1H

-0.07 bobbin 17 11 17 81 DOS

=

0.43 1H 0.04 bobbin 17

=

11 17 87 DOS.

0.59 1H 0

bobbin 17.

11 17 89 DOS 0.28 1H 0.06 bobbin 17 11 18 8

DOS I 0.19 1 H 0.09 bobbin 35.

11 18 11 DOS 0.61 1 H

-0.08 bobbin 14 11 18 11 DOS

=

0.33 2H

-0.08 bobbin 14

=

11 18 30 DOS 0.63 1 H 0.04 bobbin 14 Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind

%TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 11 18 31 SAI 0.25 2H

-0.04 Plus Point 37 OD 11 18 36 DOS 0.68 1 H

-0.04 bobbin 15 11 18 54 DOS 0.48 1H 0

bobbin 30 11 18 55 DOS 0.3 1H 0.13 bobbin 30 11 18 60 DOS 0.48 1 H 0.09 bobbin 30

=

11 18 62 DOS 1.1 1H 0.02 bobbin 32 11 18 67 DOS

=

0.33 3H

-0.04 bobbin 18

=

11 18 71 DOS.

0.44 1 H 0.08 bobbin 18 11 18 72 DOS 1.19 1 H

-0.04 bobbin 18 11 18 74 DOS 1

1H 0.04 bobbin 18.

11 18 76 SAI 0.13 1H

-0.23 Plus Point 93 OD 11 18 77 DOS 0.59 1H

-0.13 bobbin 18 11 18 81 DOS

=

0.81 1H

-0.08 bobbin 18

=

11 18 82 DOS

=

0.42 1H 0

bobbin 18

=

11 18 83 DOS I 0.48 1 H

-0.08 bobbin 18 11 18 89 TWD 6

0.38 2C

-0.17 bobbin 18

=

11 19 15 SAI 1.13 3H 0

Plus Point 21 ID 11 19 15 DIS

=

1.22 3H

-0.02 bobbin 13

=

11 19 23 SAI 0.26 2H

-0.02 Plus Point 71 OD 11 19 23 DOS 0.43 2H 0

bobbin 13 11 19 31 SAI 0.16 2H 0.14 Plus Point 70 OD 11 19 31 SAI 0.17 2H 0.03 Plus Point 70 OD 11 19 31 DOS 0.35 1H

-0.02 bobbin 15 11 19 31 DOS 0.58 2H 0

bobbin 15 11 19 39 SAI

=__ 0.8 1H 0.01 Plus Point 70 OD Plugged SAI-OD, >2v DOS @ 1H 11 19 39 DOS

=

2.24 1H 0.02 bobbin 15

=

Plugged SAI-OD, >2v DOS 1H 11 19 40 DOS 0.63 2H

-0.06 bobbin 15 11 19 42 DOS

=

0.67 1 H

-0.02 bobbin 16

=

11 19 44 DOS 1.24 1H 0.02 bobbin 16 11 19 46 SAI

=

0.21 1H 0.02 Plus Point 70 OD I 11 19 46 SAI 0.32 1H

-0.01 Plus Point 70 OD 11 19 46 DOS 0.9 1H

-0.06 bobbin 16 11 19 46 DOS 0.37 3H

-0.06 bobbin 16 11 19 48 DOS 0.69 1H 0.13 bobbin 15 11 19 49 DOS 0.49 1H

-0.07 bobbin 15 11 19 52 SAI 0.1 IH 0.08 Plus Point 69 OD 11 19 52 DOS 0.57 1 H 0.21 bobbin 29 11 19 52 DOS

=

0.9 2H 0.26 bobbin 29

=

11 19 55 DOS

=

0.68 1H 0.19 bobbin 29 11 19 56 DOS 0.7 1

H 0.04 bobbin 29 11 19 56 DOS.

0.55 2H 0.15 bobbin 29 11 19 56 DOS 0.77 3H

-0.09 bobbin 29 11 19 59 DOS I 1.02 1H 0.09 bobbin 29 11 19 60 DOS

=

1.24 1 H 0.09 bobbin 29

=

Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 11 19 61 SAI 0.23 1H

-0.11 Plus Point 46 OD 11 19 61 SAI 0.36 1H

-0.18 Plus Point 46 OD 11 19 61 DOS

=

0.85 1H 0.02 bobbin 31

=

11 19 64 DOS I__

0.78 1H 0.06 bobbin 32 11 19 67 DOS 0.28 1H -0.09 bobbin 17 11 19 68 DOS 0.34 2H 0.04 bobbin 18 11 19 73 DOS

=

0.17 1H 0

bobbin 17

=

11 19 75 DOS

=

0.94 1H 0

bobbin 17

=

11 19 83 DOS 0.31 1H 0

bobbin 17 11 19 84 DOS 0.34 2H 0.02 bobbin 17 11 19 87 DOS 1.06 1H 0

bobbin 17 11 20 18 DOS 0.36 2H

-0.17 bobbin 14 11 20 27 DOS 0.35 4H

-0.06 bobbin 14 11 20 28 SAI

=

0.91 2H

-0.16 Plus Point 21 ID 11 20 28 SAI

=

0.49 TEH 1.13 Plus Point 34 ID 11 20 28 SAI

=

1.26 TEH 0.87 Pius Point 34 ID 11 20 28 SAI

=

0.36 TEH 1.29 Plus Point 34 ID 11 20 28 SAI 0.34 TEH 1.29 Plus Point 34 ID 11 20 28 SAI 0.45 TEH 1.29 Plus Point 34 ID

-11 20 28 SAI 0.41 TEH 1.29 Plus Point 34 ID 11 20 28 SAI 0.31 TEH 1.29 Plus Point 34 ID 11 20 28 SAI 0.58 TEH 1.13 Plus Point 34 ID 11 20 28 SAI 0.74 TEH 0.88 Plus Point 34 ID 11 20 28 SAI 0.61 TEH 0.73 Plus Point 34 ID 11 20 28 SAI 0.84 TEH 1.28 Plus Point 34 ID 11 20 28 DIS 1.63 2H

-0.22 bobbin 14 11 20 29 SAI 0.73 2H 0.13 Plus Point 21 ID 11 20 29 SAI

=

0.46 TEH 0.79 Plus Point 34 ID 11 20 29 SAI 0.48 TEH 0.75 Plus Point 34 ID 11 20 29 SAI

=

1.18 TEH 1.47 Plus Point 34 ID 11 20 29 SAI

=

1.9 TEH 1.46 Plus Point 34 ID 11 20 29 SAI 1.01 TEH 1.46 Plus Point 34 ID 11 20 29 SAI 0.93 TEH 1.45 Plus Point 34 ID 11 20 29 SAI 0.81 TEH 1.84 Plus Point 34 ID 11 20 29 SAI 0.57 TEH 2.02 Plus Point 34 ID 11 20 29 SAI 0.99 TEH 1.12 Plus Point 34 ID 11 20 29 SAI 1.96 TEH 1.5 Plus Point 34 ID 11 20 29 SAI 1.31 TEH 1.76 Plus Point 34 ID 11 20 29 SAI 1.15 TEH 1.47 PlusPoint 34 ID 11 20 29 SAI 2

TEH 1.46 Plus Point 34 ID 11 20 29 SAI I__

0.71 TEH 0.65 Plus Point 34 ID 11 20 29 DIS 0.56 2H 0.13 bobbin 14 11 20 33 SAI 0.3 1H

-0.16 Plus Point 21 ID 11 20 35 DOS 0.34 1H1-0.13 bobbin 16 Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind

%TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 11 20 40 SAI

=

0.14 1H 0.09 Plus Point 70 OD 11 20 40 SAI 0.14 1H 0.01 Plus Point 70 OD 11 20 40 SAI 0.17 3H 0

Plus Point 70 OD 11

.20 40 DOS 0.38 1 H

-0.15 bobbin 16 11 20 40 DOS 0.3 3H

-0.06 bobbin 16.

11 20 41 DOS

=

0.2 1H 0

bobbin 16

=

11 20 42 DOS 0.34 1H

-0.06 bobbin 15 11 20 44 SAI 0.57 TSH -8.25 Plus Point 54 ID 11 20 46 SAI 0.18 2H

-0.04 Plus Pointl 70 OD 11 20 46 DOS 0.24 2H

-0.24 bobbin 15 11 20 47 SAI 0.9 1H

-0.1 Plus Point 74 OD 11 20 47 SAI 0.18 1H

-0.03 Plus Point 74 OD 11 20 47 DOS 1.49 1H

-0.15 bobbin 16 11 20 49 DOS

=

0.87 1 H

-0.08 bobbin 16 1

11 20 51 DOS

=

0.8 1H 0.09 bobbin 30

=

11 20 54 SAI 4

1 H 0.03 Plus Point 44 OD Plugged tube pull ODSCC ARC 11

.20 54 SAI _

0.27 1 H 0

Plus Point 44 OD Plugged tube pull ODSCC ARC 11 20 54 SAI

=

0.08 1 H 0.07 Plus Point 44 OD Plugged

. tube pull ODSCC ARC 1 1-20 54 DOS

=

5.6 1H 0.13 bobbin 41

=

Plugged tube pull ODSCC ARC 11

'20 65 SAI

=

0.57 TEH 1.26 Plus Point 45 ID 11 20 65 SAI 0.64 TEH 1.41 Plus Point 45 ID 11 20 65 SAI 1.2 TEH 1.58 Plus Point.45 ID 11 20 65 SAI 0.4 TEH 1.72 Plus Point 45 ID 11 20 65 DOS 0.93 1 H 0.02 bobbin 18 11 20 67 DOS _I 0.78 1H 0

bobbin 18 11 20 72 DOS

=

0.25 2H

-0.09 bobbin 18

=

11 20 76 SAI

=

0.29 3H 0.03 Plus Point 69 OD 11 20 76 DOS

=

0.97 3H 0.02 bobbin 17 11 20 77 DOS 0.63 2H

-0.11 bobbin 18 11 20 88 TWD 5

0.32 1C

-0.17 bobbin 18 11 21 13 SAI 0.78 3H

-0.04 Plus Point 71 ID I 11 21 13 DIS 0.51 3H

-0.07 bobbin 13 11 21 29 DOS

=

0.68 2H

-0.15 bobbin 13

=

11 21 31 DIS 0.85 2H

-0.11 bobbin 15 11 21 32 DOS 0.25 1H

-0.06 bobbin 15 11 21 35 DOS 0.33 1 H

-0.04 bobbin 15 11 21 35 DOS 0.21 4H

-0.13 bobbin 15 11 21 36 DOS 0.58 1 H 0

bobbin 15 11 21 36 DOS 1

3H 0

bobbin 15 11 21 42 DOS 0.52 1 H 0

bobbin 16 11 21 42 DOS 0.73 3H 0.08 bobbin 16 11 21 49 SAI 0.18 1H 0.05 Plus Point 70 OD 11 21 51 SAI 0.43 2H

-0.07 Plus Point 69 ID 11 21 51 DIS 0.5 2H 0.21 bobbin 29 Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal ID/OD Tube Status Reason for Repair 11 21 54 SAt 0.67 1H

-0.02 Plus Point 81 ID 11 21 54 DIS 0.5 IH 0

bobbin 29 11 21 55 DOS

=

0.49 1H 0.04 bobbin 29

=

11 21 57 DOS

=

0.59 1H 0.04 bobbin 30

=

11 21 60 DOS

=

0.24 IH 0.04 bobbin 29

=

=

11 21 65 SAI 0.18 2H

-0.1 Plus Point 69 OD 11 21 65 SAI 0.1 2H

-0.04 Plus Point 69 OD 11 21 65 DOS 0.53 2H

-0.17 bobbin 17 11 21 81 DIS.

0.56 2H

-0.09 bobbin 17 11 21 87 TWD 5 0.28 IC

-0.22 bobbin 17 11 22 23 SAI

=

0.88 2H

-0.23 Plus Point 21 ID 11 22 23 SAI 0.67 2H 0.15 Plus Point 21 ID 11 22 23 SAI

=

0.47 2H 0.43 Plus Point 21 ID 11 22 23 DIS

=

1.04 2H

-0.28 bobbin 14 11 22 38 DOS

=

0.91 IH

-0.09 bobbin 15 11 22 40 DOS 0.4 IH 0

bobbin 16 11 22 44 DOS 0.57 2H

-0.04 bobbin 16 11 22 46 DOS 0.94 1H

-0.17 bobbin 15 11 22 52 DOS 0.98 1H

0.

bobbin 30.

11 22 54 DOS

._._ 1.3 IH 0

bobbin 30 11 22 59 DOS 0.29 4H

-0.04 bobbin 30 11 22 64 DOS.

0.85 IH 0.09 bobbin 31 11 22 66 DOS 0.38 IH 0

bobbin 18 11 22 68 DOS

=

0.52 1H 0.07 bobbin 17 1

11 22 69 SAI

=

1.41 IH 0

Plus Point 74 OD 11 22 69 SAI 0.15 1H 0.01 Plus Point 74 OD 11 22 69 DOS 1.63 1H 0.11 bobbin 31 11 22 69 DOS 0.64 2H

-0.06 bobbin 31 11 22 70 SAI 0.4 1 H

-0.11 Plus Point 93 OD I 11 22 70 SAI 0.32 IH

-0.08 Plus Point 93 OD 11 22 70 DOS 1.07 1H

-0.07 bobbin 17.

11 23 14 SAI.

0.55 3H

-0.1 Plus Point 21 ID 11 23 14 DIS 0.62 3H

-0.11 bobbin 13 11 23 20 DOS.

0.63 1 H

-0.02 bobbin 13 1

11 23 20 DOS 0.27 4H

-0.04 bobbin 13 11 23 21 DOS 0.25 3H

-0.04 bobbin 13 11 23 28 DOS 1.25 1H 0

bobbin 13

=

11 23 30 DOS 0.47 3H

-0.13 bobbin 13 =3_

11 23 41 SAI 1.35 1H

-0.07 Plus Point 74 OD 11 23 41 DOS 1.44 IH

-0.09 bobbin 15 11 23 43 SAI 0.64 1H 0.11 Plus Point 74 OD 11 23 43 DOS 1.42 1H 0.13 bobbin 15 11 23 51 DOS 1.21 1H 0.13 bobbin 29

=

11 23 52 DOS 0.19 1H 0

bobbin 29

=

Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind

%oTW Volts Loc Inch Probe Cal ID/OD Tube Status Reason for Repair 11 23 55 DOS 0.69 1H 0

bobbin 29

=

11 23 58 SAI 0.15 3H 0

Plus Point 45 OD 11 23 58 DOS 0.49 3H 0.02 bobbin 29 11 23 59 SAI 0.37 1H

-0.03 Plus Point 69 OD 11 23 59 SAI

=

0.18 1H 0.01 Plus Point 69 OD 11 23 59 SAI 0.3 1H 0.19 Plus Point 69 OD 11 23 59 DOS 0.59 1H 0.04 bobbin 29 11 23 60 DOS 0.22 1H 0.04 bobbin 29 11 23 66 DOS 0.38 1H 0

bobbin 41 11 23 74 DOS 0.5 1H 0

bobbin 17 11 23 87 TWD 3

0.2 2C 0.06 bobbin 17 11 23 88 TWD 11 0.68 2C

-0.15 bobbin 17 11 24 17 DOS 0.56 1H 0.09 bobbin 14 11 24 25 DOS 0.4 1H

-0.08 bobbin 14

=

11 24 31 SAI 2.3 1H -0.03 Plus Point 26 OD Plugged SAI-OD, >2v DOS @ IH 11 24 31 SAI 1.34 IH

-0.1 Plus Point 26 OD Plugged SAI-OD, >2v DOS a@1 H 11 24 31 SAI 0.21 1H -0.09 Plus Point 26 OD Plugged SAI-OD, >2v DOS @ 1H 11 24 31 SAI 0.19 IH

-0.09 Plus Point 26 OD Plugged SAI-OD, >2v DOS @1H 11 24 31 DOS 4.45 1H 0

bobbin 39 Plugged SAI-OD,>2vDOS @1H 11 24 40 DOS 1.09 1H

-0.19 bobbin 16 11 24 42 DOS 0.5 1H 0.02 bobbin 16 11 24 43 DOS 0.31 1H 0.06 bobbin 16 11 24 48 DOS 0.24 1H 0

bobbin 16 11 24 49 DOS 0.44 1H -0.04 bobbin 16 11 24 51 SAI 0.32 IH 0.1 Plus Point 50 OD 11 24 51 DOS 0.24 1H 0.13 bobbin 30

=

11 24 59 DIS 0.48 1H 0.09 bobbin 30 11 24 67 SAI 0.81 2H

-0.08 Plus Pointl 21 ID 11 24 67 DIS 0.47 2H

-0.06 bobbin 18 11 24 71 DOS 0.33 IH

-0.08 bobbin 18 11 24 77 DOS 0.36 1H

-0.04 bobbin 18 11 24 80 DOS 0.68 IH

-0.13 bobbin 17 11 24 87 TWD 19 1.28 2C

-0.17 bobbin 18 11 25 30 DOS 0.42 2H 0.06 bobbin 13 11 25 37 SAI 0.66 IH 0.1 Plus Point 74 OD I

11 25 37 DOS 1.46 IH 0.04 bobbin 15 11 25 39 DOS 1.18 IH 0.04 bobbin 15 11 25 40 SAI 0.31 TEH 0.85 Plus Point 34 ID 11 25 40 DOS 0.35 IH 0

bobbin 15 11 25 43 SAI 0.14 2H 0.15 Plus Point 70 OD 11 25 43 DOS 0.67 2H 0.04 bobbin 15 11 25 44 SAI 0.99 1H 0.04 Plus Pointl 74 OD 11 25 44 DOS 1.44 1H 0.04 bobbin 15 11 25 46 DOS

=

0.97 1H 0

bobbin 15

=

Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %W IVolts Loc Inch Probe lCal IDIOD Tube Status Reason for Repair 11 25 52 DOS

=

0.81 1H 0.04 bobbin 29

=

11 25 53 DOS 1.06 IH

-0.09 bobbin 29 11 25 54 DOS 0.64 IH 0.06 bobbin 29 11 25 56 DOS 0.34 1H 0

bobbin 29 11 25 56 DOS.

0.24 3H 0.02 bobbin 29 11 25 57 SAI 0.72 3H 0.09 Plus Point 21 ID 11 25 57 SAI 0.98 TEH 1.16 Plus Point 45 ID 11 25 57 SAl 0.44 TEH 1.16 Plus Point 45 ID

._=

11 25 57 SAl 2.74 TEH 0.7 Plus Point 45 ID 11 25 57 SAl 3.51 TEH 0.7 Plus Point 45 ID 11 25 57 SAI 1.98 TEH 0.7 Plus Point 45 ID 11 25 57 SAI 2.52 TEH 0.66 Plus Point 45 ID 11 25 57 SAI 1.17 TEH 0.71 Plus Point 45 ID 11 25 57 SAI I 1.78 TEH 0.69 Plus Point 45 ID 11 25 57 DIS 0.28 3H 0.13 bobbin 29

=

11 25 62 TWD 19 0.39 7H 44.44 bobbin 31 11 25 62 TWD 25 0.61 7H 63.55 bobbin 31

=

11 25 65 DOS

=

0.61 IH 0

bobbin 17

=

11 25 66 DOS

=

0.92 IH 0.06

' bobbin 17',.

11 25 69 DOS 1.07 1H 0

'bobbin 17 :

11 25 70 SAI 0.18 1H

-0.03 Plus Point 93 OD 11 25 70 DOS

=

0.2 1H

-0.04 bobbin 17 7 11 25 73 DOS 0.19 1 H 0

bobbin 17 11 25 85 TWD 10 0.64 1C 0.06 bobbin 17 11 25 86 TWD 14 0.92 2C

-0.2 bobbin 17 11 25 87 VOL 0.29 1C 0.03 Plus Point 66 OD I 11 25 87 TWD 7

0.45 IC 0.02 bobbin 17 11 26 19 SAI 0.12 2H

-0.09 Plus Point 71 OD 11 26 19 DOS 0.46 2H

-0.09 bobbin 6

11 26 25 SAI 1.31 1H 0.22 Plus Point 21 ID Plugged SAI ID/OD c 1H 11 26 25 SAI 0.22 1H

-0.14 Plus Point 21 OD Plugged SAI ID/OD © IH 11 26 25 DIS

=

1.44 IH 0.24 bobbin 6

Plugged SAI ID/Ol)

IH 11 26 28 SAI

=

0.29 1H

-0.07 Plus Point 40 OD 11 26 32 SAI 0.58 1H -0.01 Plus Point 74 OD 11 26 32 SAI 0.36 IH

-0.01 Plus Point 74 OD 11 26 32 DOS.

1.55 1H 0.04 bobbin 39.

11 26 33 SAI 0.14 1H

-0.22 Plus Point 92 OD 11 26 34 SAI 0.46 1H

-0.09 Plus Point 70 OD 11 26 34 DOS 0.53 IH

-0.13 bobbin 10 11 26 36 DOS 0.36 IH 0.04 bobbin 33 11 26 37 DOS 0.47 IH 0.04 bobbin 11 11 26 38 DOS

=

0.71 1 H

-0.02 bobbin 11

=

11 26 41 DIS 0.79 2H

-0.17 bobbin 11 11 26 42 DOS.

1.2 1H

-0.06 bobbin 11 Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal ID/OD Tube Status Reason for Repair 11 26 42 DIS 0.6 2H

-0.06 bobbin 11 11 26 43 DOS 1.22 1 H 0

bobbin 11 11 26 44 DOS

=

0.31 1 H

-0.04 bobbin 11 I 11 26 44 DOS 0.35 2H

-0.11 bobbin 11 11 26 46 SAI

=

0.67 1H 0.07 Plus Point 92 OD I 11 26 47 DOS 0.33 IH

-0.07 bobbin 11

=

11 26 52 DOS 0.65 1H 0.11 bobbin 20

=

11 26 56 DOS 0.52 IH

-0.1 bobbin 20 11 26 56 DOS 0.44 2H 0.08 bobbin 20 11 26 60 SAI 0.22 1 H 0.01 Plus Point 74 OD' 11 26 60 SAI _

0.24 1H 0.16 Plus Point 74 OD 11 26 60 SAI 0.66 1H

-0.05 Plus Pointl 74 OD 11 26 60 DOS 1.41 1H 0.08 bobbin 20 11 26 60 DOS

=

0.24 2H 0.02 bobbin 20

=

11 26 61 SAI

=

0.33 1 H

-0.04 Plus Point 69 OD Plugged SAI-OD. >2v DOS @ 1 H 11 26 61 SAI 0.79 1 H

-0.1 Plus Point 69 OD Plugged SAI-OD, >2v DOS @ IH 11 26 61 SAI 0.75 1 H

-0.02 Plus Point 69 OD Plugged SAI-OD, >2v DOS @ I H 11 26 61 DOS 2.03 1H 0.04 bobbin 19 Plugged SAI-OD, >2v DOS @ 1H 11 26 61 DIS 0.51 2H 0

bobbin 19 Plugged SAI-OD, >2v DOS @ IH 11 26 63 SAI.

0.83 1H

-0.09 Plus Point 69 OD 11 26 63 SAI 0.22 1 H 0.03 Plus Point 69 OD 11 26 63 DOS 1.92 1H 0

bobbin 31 11 26 66 DOS 0.6 1H 0.04 bobbin 21 11 26 67 DOS 0.37 IH 0.1 bobbin 21 11 26 77 SAI 0.53 IH

-0.02 Plus Point 69 OD Plugged SAI-OD, >2v DOS @ I H 11 26 77 SAI 0.6 1 H 0.06 Plus Point 69 OD Plugged SAI-OD >2v DOS a I H 11 26 77 SAI 0.18 1H

-0.03 Plus Point 69 OD Plugged SAI-D, >2v DOS @ 1H 11 26 77 SAI 0.78 1H

-0.13 Plus Point 69 OD Plugged SAI4-D, >2v DOS @ IH 11 26 77 SAI 0.4 1H 0.01 Plus Point 69 OD Plumed SAI4-D >2v DOS a 1H 11 26 77 DOS 2.01 1H 0.06 bobbin 41 Plugged SAI-OD >2v DOS @ 1 H 11 26 86 TWD 16 1.01 2C

-0.21 bobbin 31 11 27 23 DOS 0.26 1 H

-0.02 bobbin 6

11 27 28 SAI 0.23 1H 0.2 Plus Point 70 OD 11 27 28 DOS 0.51 IH 0.15 bobbin 6

11 27 32 DOS 0.63 1H 0.06 bobbin 9

11 27 34 DOS 0.21 1 H 0.06 bobbin 9

11 27 35 DOS 0.4 1H 0.02 bobbin 9

11 27 36 DOS 0.99 1 H 0

bobbin 9

=

11 27 39 DOS 0.53 1 H 0.02 bobbin 11

=

11 27 40 DOS 1.14 1H 0.02 bobbin 12 11 27 41 DOS 0.79 1 H

-0.09 bobbin 11 11 27 42 SAI 1.23 1 H 0.03 Plus Point 70 OD 11 27 42 SAI 0.14 IH 0.03 Plus Point 70 OD 11 27 42 DOS 1.79 1H 0.11 bobbin 39

=

Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind

%TW Volts Loc Inch Probe Cal ID/OD Tube Status Reason for Repair 11 27 44 SAI 0.26 2H

-0.02 Plus Point 31 OD 11 27 44 DOS 0.95 1

H -0.11 bobbin 12 11 27 46 DOS 0.39 1H

-0.04 bobbin 12 11 27 52 SAI _

0.22 1H

-0.02 Plus Point 69 OD 11 27 52 SAI 0.18 1H 0.1 Plus Point 69 OD 11 27 52 SAI 1.63 1 H 0.04 Plus Point 69 OD 11 27 52 DOS 1.96 1H 0.08 bobbin 19 11 27 54 DOS 0.6 1H 0.15 bobbin 20 11 27 64 DOS I___

0.51 5H 0.08 bobbin 19 11 27 65 DOS 0.47 1 H 0.08 bobbin 22 11 27 67 DOS 0.37 1H 0

bobbin 21 11 27 69 DOS 0.46 1 H 0.12 bobbin 22 11 27 70 DOS

=

0.22 1 H 0

bobbin 22

=

11 27 75 SAI 0.92 2H 0.01 Plus Point 21 ID 11 27 75 DIS 0.74 2H 0.04 bobbin 22

=

11 27 80 DOS 0.59 1H 0.02 bobbin 22 11 28 25 SAI 0.12 2H 0.08 Plus Point 70 OD 11 28 25 DOS 0.13 2H 0.02 bobbin 8

11 28 26 DOS 0.69 1H 0.02

'bobbin 6

11 28 27 SAI 0.3 1H 0.26 Plus Point 21 OD Plugged SAI ID/OD @ 1H 11 28 27 SAI 0.19 1H

-0.03 Plus Point 21 OD Plugged SAI ID/OD @ 1H 11 28 27 SAI 1.22 1 H

-0.26 Plus Point 21 ID Plugged SAI ID/OD @ 1H 11 28 27 DIS 0.86 1H

-0.08 bobbin 8

Plugged SAI ID/OD @ 1H 11 28 27 DIS 1.38 1 H

-0.26 bobbin 8

Plugged SAI ID/OD @ 1 H 11 28 29 DOS 0.32 1 H

-0.06 bobbin 10 11 28 31 DOS 0.36 1H 0.02 bobbin 9

11 28 31 DOS 0.87 2H

-0.06 bobbin 9

11 28 32 SAI 0.48 1 H 0.04 Plus Point 74 OD 11 28 32 SAI 0.47 1H 0.04 Plus Point 74 OD 11 28 32 DOS 1.45 1H 0

bobbin 10 11 28 34 DOS 1.14 1H 0.08 bobbin 10 11 28 36 SAI 0.14 1H

-0.13 Plus Pointl 92 OD 11 28 38 DOS 0.31 1H

-0.06 bobbin 11 11 28 39 DOS 0.42 1H

-0.02 bobbin 12 11 28 40 SAI 0.26 1H

-0.17 Plus Point 70 OD 11 28 40 DOS 0.28 1 H

-0.13 bobbin 11 11 28 41 SAI 1.84 TEH 0.9 Plus Point 35 ID 11 28 41 DOS 1.37 1 H 0.13 bobbin 49 11 28 41 DOS 0.36 4H

-0.02 bobbin 49 11 28 43 DOS 0.39 1 H

-0.02 bobbin 11 11 28 45 DOS 0.43 1 H

-0.06 bobbin 12 2 11 28 47 DOS 0.46 1 H 0.07 bobbin 11 11 28 48 DOS 0.95 1 H 0.09 bobbin 11 11 28 48 TWD 27 0.83 7H 84.73 bobbin 11

=

Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind

%TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 11 28 48 TWD 21 0.52 7H 73.24

  • bobbin 11 I1 28 48 TWD 14 0.28 7H 50.5 bobbin 11 11 28 49 DOS 0.74 1 H 0

bobbin 12 11 28 52 DOS 0.84 1 H 0.1 bobbin 20 11 28 53 DOS 1.21 1 H 0

bobbin 20 11 28 54 DOS 0.45 1 H 0.13 bobbin 19 11 28 55 DOS 1.02 1 H 0.08 bobbin 20 11 28 59 DOS 0.91 1 H 0.12 bobbin 20

=

11 28 63 DOS 0.37 2H 0.04 bobbin 20 11 28 65 SAI 0.6 1 H 0.03 Plus Point 69 OD 11 28 65 DOS

=

0.69 1 H 0.11 bobbin 21

=

11 28 85 TWD 18 1.17 IC

-0.11 bobbin 31 X

11 29 19 SAI 0.33 1H

-0.07 Plus Point 71 OD Plugged SAI-OD@ 1HWedge 11 29 19 DOS 0.67 1 H -0.04 bobbin 8 _

Plugged SAI-OD @ I H Wedge 11 29 24 DOS _

0.52 2H 0

bobbin 6 1 1

11 29 25 DOS 0.29 1 H 0.04 bobbin 6

11 29 25 DOS 0.89 3H

-0.3 bobbin 6

11

29 27 DOS

=

0.23 1 H

-0.02 bobbin 6

=

11 29 29 SAI 0.76) 2H

-0.1 Plus Point 70 OD 11 29 29 DOS 1.5 2H

-0.17 bobbin 9

11 29 31 DOS.

0.57 1 H 0

bobbin 10 11 29 33 SAI 1.42 1H

-0.06 Plus Point 70 OD Plugged SAI-OD, >2v DOS @ 1 H 11 29 33 SAI 0.82 1 H 0.05 Plus Point 70 OD Plugged SAI-OD, >2v DOS @ 1 H 11 29 33 DOS _

2.73 1H

-0.04 bobbin 9

Plugged SAI-OD, >2v DOS @ 1H 11 29 34 DOS 0.7 1 H 0.08 bobbin 9

11 29 35 DOS 0.55 1H 0.17 bobbin 37 11 29 37 SAI 0.71 2H 0.08 Plus Point 21 ID 11 29 37 SAI 1.11 TEH 1.2 Plus Point 35 ID 11 29 37 SAI 1.98 TEH 1.22 Plus Point 35 ID 11 29 37 SAI 0.71 TEH 1.23 Plus Point 35 ID 11 29 37 SAI 0.96 TEH 1.23 Plus Point 35 ID 11 29 37 SAI 1.5 TEH 1.53 Plus Point 35 ID 11 29 37 SAI 0.54 TEH 1.21 Plus Point 35 ID 11 29 37 SAI 0.35 TEH 1.21 Plus Point 35 ID 11 29 37 SAI 0.32 TEH 1.37 Plus Point 35 ID 11 29 37 SAI 1.01 TEH 1.37 Plus Point 35 ID 11 29 37 SAI 0.49 TEH 1.37 Plus Point 35 ID 11 29 37 SAl 0.44 TEH 1.36 Plus Point 35 ID 11 29 37 SAI 0.66 TEH 1.38 Plus Point 35 ID 11 29 37 SAI 1.08 TEH 1.38 Plus Point 35 ID I 11 29 37 SAI 1.95 TEH 1.38 Plus Point 35 ID 11 29 37 SAI 0.75 TEH 1.37 Plus Point 35 ID 11 29 37 SAI 1.04 TEH 1.52 Plus Point 35 ID 11 29 37 SAl 1.89 TEH 1.53 Plus Point 35 ID Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal ID/OD Tube Status Reason for Repair 11 29 37 SAI 1.34 TEH 1.53 Plus Point 35 ID 11 29 37 SAI 0.64 TEH 1.66 Plus Point 35 ID 11 29 37 SAI 1.13 TEH 1.67 Plus Point 35 ID 11 29 37 SAI 0.68 TEH 1.65 Plus Point 35 ID 11 29 37 SAI 1.47 TEH 1.52 Plus Point 35 ID 11 29 37 DIS 0.7 2H 0.08 bobbin 12 11 29 38 DOS 1.24 1H 0.08 bobbin 12

=

11 29 39 SAI 0.2 1H

-0.09 Plus Point 70 OD I 11 29 39 DOS 0.52 1 H

-0.07 bobbin 11 11 29 41 SAI 0.34 1H

-0.13 Plus Point 74 OD 11 29 41 SAI 0.67 1H

-0.13 Plus Point 74 CD 11 29 41 SAI 0.28 1H

-0.14 Plus Point 74 OD 11 29 41 SAI 0.26 1H

-0.2 Plus Point 74 OD 11 29 41 DOS 1.65 1 H

-0.02 bobbin 41

=

11 29 43 SAI 0.6 1H

-0.01 Plus Point 70 CD 11 29 43 DOS 1.72 1H 0.04 bobbin 39 11 29 45 DOS 0.63 1H 0.06 bobbin 11 11 29 46 SAI 0.29 1H

-0.03 Plus Point 74 CD Plugged SCI-4D & SAI-D @ 1H 11 29 46 SAI 0.28 1 H 0.08 Plus Point 74 OD Plugged SCI-OD & SAI-D @ 1 H 11 29 46 SAI

'0.26 1H 0.02 Plus Point 74 OD Plugged SCI4D & SAI-CD @ 1H 11 29 46 SCI 0.8 1H

-0.03 Pius Point 74 OD Plugged SCI4-D & SAI4-D @ 1H 11 29 46 DOS 1.44 11H 0.06 bobbin 39 Plugged SCI-4D & SAI-CD @ 1H 11 29 47 DOS 0.55 1H 0.02 bobbin 11 11 29 49 DIS 0.31 1H

-0.02 bobbin 11

=

11 29 55 DOS 0.58 1H

-0.06 bobbin 19

=

11 29 60 DOS 0.44 2H 0.02 bobbin 19 9 11 29 62 DOS 0.83 1 H 0.06 bobbin 19 11 29 63 DOS 0.48 1 H 0.08 bobbin 19 11 29 64 DOS 0.98 1 H 0.17 bobbin 19 11 29 72 DOS 0.39 1 H 0.04 bobbin 22 11 29 84 TWD 22 1.5 2C

-0.17 bobbin 31 11 30 21 SAI 0.6 2H

-0.07 Plus Point 21 ID 11 30 21 DIS 0.73 2H

-0.36 bobbin 8

11 30 22 DOS 0.52 4H

-0.21 bobbin 6

11 30 29 DOS 0.28 1 H 0.04 bobbin 10 11 30 30 SAI 0.24 2H

-0.01 Plus Point 70 OD 11 30 30 DOS 0.31 2H

-0.04 bobbin 10 11 30 31 DOS 1.09 1H 0

bobbin 9

11 30 31 DOS 0.61 2H

-0.06 bobbin 9

11 30 35 SAI 0.29 1H

-0.02 Plus Point 74 OD 11 30 35 SAI 0.79 1H 0.01 Plus Point 74 OD 11 30 35 DOS 1.51 1H 0

bobbin 9

=

11 30 37 SA

=

1.03 1H

-0.09 Plus Point 70 OD Plugged SAI-OD, >2v DOS @ IH 11 30 37 DOS 2.03 1H

-0.06 bobbin 41

=

Plugged SAI-OD, >2v DOS @ IH A :

Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal ID/OD Tube Status Reason for Repair 11 30 39 DOS 0.93 1H 0.06 bobbin 12 11 30 40 DOS 1.08 1H -0.11 bobbin 11 11 30 44 SAI 0.21 1H 0

Plus Point 70 OD II 30 44 SAI

=

1.22 1H 0.09 Plus Point 70 OD 11 30 44 SAI 0.17 1H 0.04 Plus Point 70 OD 11 30 44 DOS 1.84 1H 0.04 bobbin 39 11 30 45 DOS 0.27 1H 0

bobbin 12 11 30 48 DOS 1.39 1H 0.04 bobbin 11 11 30 53 DOS 0.86 1H 0.13 bobbin 20.

11 30 54 DOS I___0.79 1H 0.12 bobbin 19 11 30 58 SAI 0.17 4H

-0.18 Plus Point 69 OD 11 30 58 DOS 0.65 2H

.0.1 bobbin 20 11 30 58 DOS 0.57 4H

-0.02 bobbin 20 11 30 59 SAI

=

0.57 2H

-0.04 Plus Point 69 ID I 11 30 59 DIS 0.29

'2H 0

bobbin 20 11 30 61 DOS 0.87 1H -0.02 bobbin 19 11 30 63 DOS 0.31 1H 0.02 bobbin 20 11 30 66 DOS 0.96 1H

-0.04 bobbin 21 11 30 67 SAI 1.04 2H 0.09 PlusPoint 21 ID I 11

'30 67 SAI

!2.17 TEH 1.69 Plus Point 42 ID 11 30 67 SAI 1.09 TEH 1.1 Plus Point 42 ID 11 30 67 SAI 0.57 TEH 1.7 Plus Point 42 ID 11 30 67 SAI 0.94 TEH 0.97 Plus Point 42 ID 11 30 67 SAI 1.79 TEH 1.69 Pius Point 42 ID 11 30 67 SAI 0.4 TEH 1.11 Plus Point 42 ID 11 30 67 SAI 1.53 TEH 1.25 Plus Point 42 ID 11 30 67 SAI 0.63 TEH 1.25 Plus Point 42 ID 11 30 67 SAI 0.65 TEH 1.24 Plus Point 42 ID 11 30 67 SAI 0.68 TEH 1.39 Plus Point 42 ID 11 30 67 SAI 0.67 TEH 1.39 Plus Point 42 ID 11 30 67 SAI 0.84 TEH 1.38 Plus Point 42 ID 11 30 67 SAI 1.31 TEH 1.56 Plus Point 42 ID 11 30 67 SAI 0.81 TEH 1.54 Plus Point 42 ID 11 30 67 SAI 0.6 TEH 1.53 Plus Point 42 ID 11 30 67 SAI 0.85 TEH 1.68 Plus Point 42 ID 11 30 67 DIS 1.14 2H 0.23 bobbin 22 11 30 70 DOS 1.12 1H 0.02 bobbin 21 11 30 78 PLP 0.22 TSC 3.02 Plus Point 86 11 30 78 PLP I 1.89 TSC 3.06 bobbin 21

=

11 30 78 PLP 1.94 TSC 3.02 bobbin 21 11 30 79 DOS 0.8 1H 0

bobbin 22 11 30 83 TWD 13 0.86 1C

-0.3 bobbin 31 11 31 32 DOS 0.6 1H 0

bobbin 10 11 31 37 DOS

=

0.94 1H.0.11 bobbin 12

=

1 Enclosure PG&E Letter DCL-05-028 A:

Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind

%TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 1 1 31 38 SAI 1.35 IH 0.1 Plus Point 70 00 Plugged SAI-OD, >2v DOS @ IH 11 31 38 SAI 0.56 1 H

-0.09 Plus Point 70 OD Plugged SAI-4D, >2v DOS @ 1 H 11 31 38 DOS 2.01 1H 0.13 bobbin 41 Plugged SAI-4D, >2v DOS @ 1 H 11 31 39 DOS 0.28 1H 0

bobbin 11 11 31 40 SAI 0.56 1H 0

PIus Point 92 OD 11 31 40 DOS 0.27 IH

.0.06 bobbin 12 11 31 41 DOS 1.09 IH

-0.11 bobbin 11 11 31 50 DOS 0.81 1H 0.15 bobbin 20 11 31 56 DOS 0.29 1 H 0.04 bobbin 19 11 31 63 DOS 0.6 1 H 0.1 bobbin 19 11 31 65 DOS 0.27 1 H 0.06 bobbin 22 11 31 66 DOS 0.39 2H 0

bobbin 22 11 31 69 DOS 0.48 1 H 0.1 bobbin 22 11 31 78 PLP 0.15 TSC 2.91 Plus Point 86 11 31 78 PLP 1.11 TSC 2.87 bobbin 22 11 31 78 PLP 1.57 TSC 3.16 bobbin 22 11 31 79 VOL 0.12 1C

-0.37 Plus Point 87 OD 11 31 79 TWD 11 0.72 IC

-0.33 bobbin 21

'11 31 81 VOL 0.3 IC 0.24 Plus Point 66 00 11 31 81 VOL 0.24 IC

-0.06 Plus Point 66 OD 11 31 81 TWD 9

0.57 IC

-0.11 bobbin 22 11 31 81 TWD 31 2.23 2C

-0.19 bobbin 22 11 32 23 SAI 0.25 1 H

-0.07 Plus Point 71 OD Plugged SAI-OD @ 1 H Wedge 11 32 23 DOS 0.36 1 H

-0.06 bobbin 6

Plugged SAI-OD 0 I H Wedge 11 32 23 DOS 0.77 2H

-0.11 bobbin 6

Plugged SAI-OD @ I H Wedge 11 32 24 SAI 0.21 2H

-0.22 Plus Point 92 OD 11 32 24 DOS 0.65 2H 0.02 bobbin 8

11 32 28 DOS 0.81 IH

-0.06 bobbin 8

11 32 32 DOS 0.8 1 H 0

bobbin 9

11 32 44 DOS 0.24 2H

-0.06 bobbin 11 11 32 48 DOS 0.91 2H 0.07 bobbin 11 11 32 69 DOS 0.27 2H 0.08 bobbin 21

=

11 32 78 VOL 0.12 1C 0.33 Plus Point 87 OD 11 32 78 TWD 7

0.41 IC 0.34 bobbin 21 11 32 79 VOL 0.23 IC 0.01 Plus Point 87 OD 11 32 79 TWD 16 1.07 IC 0

bobbin 22 11 33 34 SAI 0.31 IH

-0.09 Plus Point 92 OD 11 33 37 DOS 0.33 1H 0

bobbin 12 11 33 39 DOS 0.4 1H 0.04 bobbin 11 11 33 42 DOS 0.25 3H

-0.04 bobbin 12 11 33 43 DOS 1.12 1H 0.02 bobbin 12 11 33 44 DOS I 0.3 7H

-0.23 bobbin 12 11 33 55 SAI 0.99 1H 0.05 Plus Point 69 OD 11 33 55 DOS 1.28 IH 0.1 bobbin 19 Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Cot Ind %TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 11 33 57 DOS

=

0.94 1 H 0.1 bobbin 20

=

11 33 71 DOS 0.86 IH

-0.04 bobbin 21 11 33 77 TWD 11 0.7 2C

-0.32 bobbin 21 11 33 79 TWD 19 1.24 1 C 0.32 bobbin 21 11 34 24 SAI 0.53 3H 0

Plus Point 21 ID 11 34 24 SAI 0.43 3H 0.19 Plus Point 21 ID 11 34 24 DIS 0.7 3H

-0.13 bobbin 8

11 34 30 DOS 0.34 1H

-0.08 bobbin 10 11 34 41 DOS

=

0.35 2H

.0.04 bobbin 12

=

11 34 77 DOS.

0.67 IC

-0.36 bobbin 22 11 34 79 VOL 0.28 IC

-0.36 Plus Point 66 OD 11 34 79 TWD 14 0.89 IC

-0.36 bobbin 22 11 35 17 TWD 13 0.86 IC

-0.15 bobbin 8

11 35 21 DIS 0.58 4H 0.08 bobbin 6

11 35 29 DOS 0.6 IH

-0.09 bobbin 9

11 35 34 DOS 0.54 2H

-0.19 bobbin 9

11

.35 39 DOS 0.38 1 H 0

bobbin 11 11 35 43 SAI 0.89 2H

-0.14 Plus Point 70 OD Plugged SAI-OD, >2v DOS @ 2H 11 35 43 SAI 0.11 2H 0.07 Plus Point 70 OD Plugged SAI-OD, >2v DOS @ 2H 11 35 43 SAI 0.29 2H 0.07 Plus Point 70 OD Plugged SAI-OD, >2v DOS @ 2H 11 35 43 DOS 2.07 2H

-0.13 bobbin 39 Plugged SAI-OD, >2v DOS @ 2H 11 35 59 SAI 1.08 3H

-0.07 Plus Point 21 ID 11 35 59 DIS 0.83 3H 0

bobbin 19 11 35 61 DOS 1.18 2H

-0.1 bobbin 20 11 35 76 TWD 14 0.87 2C

-0.19 bobbin 22 11 35 78 VOL 0.06 IC

-0.34 Plus Point 66 OD 11 35 78 VOL 0.43 2C

-0.05 Plus Point 68 OD 11 35 78 TWD 23 1.54 1 C

-0.34 bobbin 22 11 35 78 TWD 7

0.41 2C

-0.09 bobbin 22 11 36 31 DOS 0.31 1H 0.02 bobbin 10 11 36 31 DOS 0.8 2H

-0.15 bobbin 10

=

11 36 32 DOS 0.76 IH 0.09 bobbin 9

11 36 45 SAI 0.24 1H 0.27 Plus Point 21 OD Plugged SAI-OD, >2v DOS @ 1 H 11 36 45 SAI 1.36 1H 0.02 Plus Point 21 OD Plugged SAI-OD, >2v DOS @ IH 1136 45 SAI 0.66 IH -0.01 Plus Point 21 OD Plugged SAI-OD, >2v DOS @ IH 11 36 45 DOS 3.08 IH 0.13 bobbin 41 Plugged SAI-OD, >2v DOS C 1IH 11 36 48 SAI 0.17 2H

-0.32 Plus Point 92 OD 11 36 48 SAI 0.14 2H 0.1 Plus Point 92 OD 11 36 48 SAI 0.17 2H 0.25 Plus Point 92 OD 11 36 55 SAI 0.22 1H 0.06 Plus Point 69 OD Plugged SAI-OD >2v DOS I H 11 36 55 SAI 1.19 IH

-0.04 Plus Point 69 OD Plugged SAI-OD, >2v DOS @ 1H 11 36 55 SAI 0.19 IH 0

Plus Point 69 OD Plugged SAI-OD, >2v DOS @ 1H 11 36 55 DOS 2.07 IH 0.02 bobbin 31 Plugged SAI-OD, >2v DOS _ IH 11 36 64 DOS 1.06 2H

-0.17 bobbin 20 Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind V.TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 11 36 73 TWD 10 0.59 2C

-0.21 bobbin 21 11 36 76 DOS 0.44 1 C

-0.36 bobbin 21 11 36 77 VOL 0.32 IC 0.19 Plus Point 66 OD 11 36 77 TWO 11 0.71 1C 0.17 bobbin 22 11 36 77 TWO 19 1.23 2C

-0.21 bobbin 22 11 37 32 SAI 0.97 TEH 1.35 Plus Point 35 ID 11 37 32 SAI 0.92 TEH 1.35 Plus Point 35 ID 11 37 32 DOS 0.96 1 H 0.15 bobbin 10 11 37 36 DOS 0.69 1 H 0.04 bobbin 9

11 37 41 SAI 1.25 1H

-0.03 Plus Point 74 OD 11 37 41 SAI 0.25 2H

-0.05 Plus Point 70 OD 11 37 41 DOS 1.48 1 H

-0.07 bobbin 11 11 37 41 DOS 0.38 2H

-0.13 bobbin 11 11 37 41 DOS 0.36 6H

-0.06 bobbin 11 11 37 45 SAI 0.24 2H 0.08 Plus Point 70 OD 11 37 45 DOS 0.5 2H 0.02 bobbin 11 11 37 46 TWD 34 1.32 7H 63.16 bobbin 11 11 37 54 DOS 0.38 1H 0.1 bobbin 20 11 37 56 SAI 0.22 2H 0.22 Plus Point 25 OD_

11 37 75 TWD 10 0.6 2C

-0.15 bobbin 22 11 37 76 DOS 0.6 IC

-0.34 bobbin 22 11 38 32 DOS 0.96 1H

-0.11 bobbin 9

11 38 36 DOS 1.05 1H 0.11 bobbin 39 11 38 38 DOS 0.62 1H

-0.13 bobbin 11 11 38 40 DOS 1.04 IH

-0.17 bobbin 11 11 38 40 DOS

=

0.38 4H 4.06 bobbin 11

=

11 38 41 SAI I

4H

-0.21 Plus Point 21 ID 11 38 41 DIS 1.22 4H

-0.25 bobbin 12 11 38 44 DOS 0.15 1 H 0.02 bobbin 11 11 38 44 DOS _

0.87 2H

-0.15 bobbin 11 11 38 46 DOS 0.76 1 H -0.08 bobbin 12 11 38 54 SAI 0.27 2H

-0.09 Plus Point 25 OD 11 38 66 DOS 0.88 1 H 0.08 bobbin 21 11 38 72 TWD 8

0.5 IC

-0.32 bobbin 21 11 39 54 TWD 22 0.44 7H 129.7 bobbin 20 11 39 54 TWO 29 0.78 7H 101.6 bobbin 20 11 39 54 TWO 23 0.48 7H 66.49 bobbin 20 11 39 56 TWO 18 0.35 7H 131.3 bobbin 19

=

11 39 57 SAI I__

0.52 2H

-0.17 Plus Point 21 ID 11 39 57 DIS 0.54 2H

-0.17 bobbin 20 11 39 59 SAI 0.11 2H 0.02 Plus Point 93 OD 11 39 59 DOS 0.14 2H 0.08 bobbin 19 11 39 73 TWD 11 0.71 1 C -0.36 bobbin 22 11 40 27 DOS

=

0.68 1 H

-0.02 bobbin 6

=

Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 11 40 29 DOS 0.68 1H

-0.02 bobbin 6

11 40 31 DOS 0.64 1H 0

bobbin 10 11 40 35 TWD 16 0.35 7H 104.1 bobbin 9

11 40 39 DOS 0.3 1 H

-0.02 bobbin 12 11 40 40 DOS 0.35 3H 0

bobbin 11 11 40 50 SAI 0.26 1H 0.09 Plus Point 93 OD 11 40 50 DOS 0.49 1H 0.15 bobbin 20 11 40 66 DOS 0.88 11H 0.15 bobbin 21

=

11 40 68 DOS 0.64 1H 0.08 bobbin 21 11 40 68 TWD 29 0.87 7H 103.1 bobbin 21 11 40 68 TWD 21 0.46 7H 68.1 bobbin 21 11 40 70 DOS 0.35 2H 0.04 bobbin 22 11 41 36 DOS 1.2 1H 0.04 bobbin 9

11 41 38 DOS 1.27 1 H 0.08 bobbin 12 11 41 39 DOS 0.69 1 H 0.06 bobbin 11 11 41 41 DOS 1.34 3H

-0.13 bobbin 11 11 41 44 TWD 12 0.22 7H 138.3 bobbin 12 2 11 41 44 TWD 15 0.29 7H 107.8 bobbin 12 11 41 53 DOS 0.35 2H

-0.13 bobbin 19 9 11 41 64 VOL 0.31 2C

-0.14 Plus Point 66 OD 11 41 64 TWD 21 1.44 2C

-0.23 bobbin 19.

11 41 68 SAI 0.2 2H

-0.01 Plus Point 22 OD 11 41 68 SAI 0.12 2H

-0.13 Plus Point 22 OD 11 41 68 DOS 0.42 2H 0.02 bobbin 22 11 41 68 DOS 0.5 3H

-0.11 bobbin 22 11 42 29 TWD 20 1.37 2C

-0.22 bobbin 6

11 42 30 SAI 0.24 2H 0.02 Plus Point 70 OD Plugged SAI-OD @ 2H Wedge 11 42 30 DOS 0.47 2H

-0.08 bobbin 9

=

Plugged SAI-OD @ 2H Wedge 11 42 36 SAI 0.55 1 H 0.03 Plus Point 81 OD 11 42 36 SAI 0.45 1H 0.09 Plus Point 81 OD 11 42 36 DOS 1.44 1H 0.15 bobbin 39

=

11 42 37 SAI 0.56 1H 0.04 Plus Point 70 OD Plugged SAI-OD, >2v DOS @ IH 11 42 37 SAI 0.52 1H 0.1 Plus Point 70 OD Plugged SAI-OD, >2v DOS @ IH 11 42 37 SAI 0.29 1H 0.12 Plus Point 70 OD Plugged SAI-OD, >2v DOS @ IH 11 42 37 DOS 2.37 1H 0

bobbin 9

Plugged SAI-OD, >2v DOS @ I H 11 42 40 DOS 0.47 1 H 0

bobbin 11 11 42 45 SAI 1.18 3H

-0.01 Plus Point 70 OD 11 42 45 DOS 1.78 3H 0.09 bobbin 41

=

11 42 46 SAI 0.15 1H 0.1 Plus Point 92 OD 11 42 49 DOS I 0.37 2H 0

bobbin 12 2 11 42 50 SAI 0.13 4H 0.02 Plus Point 24 OD 11 42 50 DOS 0.69 4H 0.1 bobbin 21.

11 42 51 SAI 0.19 1H 0.14 Plus Point 93 OD 11 42 54 DOS 0.29 2H 0.04 bobbin 19 I I

l Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 11 42 58 VOL 0.15 2C

-0.2 Plus Point 66 OD 11 42 58 TWD 7

0.44 2C

-0.25 bobbin 20 11 42 62 TWD 13 0.81 IC

-0.34 bobbin 19 11 42 62 DOS 0.76 2H

-0.1 bobbin 19 11 42 65 TWD 20 1.31 IC

-0.34 bobbin 20 11 43 30 TWD 20 0.44 7H 37.3 bobbin 10 11 43 40 DOS 0.61 2H

-0.02 bobbin 12 11 43 41 DOS 0.71 3H

-0.07 bobbin 11 11 43 44 DOS I 0.43 2H

-0.13 bobbin 12 11 43 47 DOS 0.76 2H

-0.21 bobbin 11 11 43 48 DOS 0.58 3H

-0.17 bobbin 12 11 44 44 DOS 0.37 1H 0

bobbin 11 11 44 47 SAI 0.61 IH

-0.03 Plus Point 70 OD 11 44 47 DOS 0.68 1 H

-0.04 bobbin 12 11 44 54 DOS 0.88 1 H 0.29 bobbin 19 11 44 55 TWD 6

0.38 2C 0.19 bobbin 21 11 44 59 TWD 7

0.46 1 C

-0.08 bobbin 20 11 44 60 VOL 0.34 2C

-0.3 Plus Point 66 OD 11 44 60 TWD 18 1.22 2C

-0.3 bobbin - 19 11 44 61 TWD 25 1.71 IC :-0.34 bobbin 19 11 45 48 DOS 0.44 1 H

-0.09 bobbin 12 11 45 59 VOL 0.15 2C

-0.3 Plus Point 66 OD 11 45 59 TWD 10 0.62 2C

-0.28 bobbin 19 11 46 48 DOS 0.46 1 H

-0.02 bobbin 12 11 46 50 SAI 0.99 1 H 0.02 Plus Point 69 OD Plugged SAI-4D, >2v DOS @ 1 H 11 46 50 DOS 0.31 IC

-0.37 bobbin 32 Plugged SAI-OD, >2v DOS @ 1 H 11 46 50 DOS 2.02 1 H 0.11 bobbin 32 Plugged SAI-OD, >2v DOS @ 1 H 11 46 51 TWD 30 2.19 IC

-0.21 bobbin 32 11 46 54 TWD 11 0.7 IC

-0.31 bobbin 22 12 1

2 DOS 0.44 2H

-0.07 bobbin 10

=

12 1

10 DIS 0.47 2H

-0.15 bobbin 10

=

12 1

21 DOS 0.36 3H 0

bobbin 9

=

12 1

44 SAI 2.96 TEH 1.16 Plus Point 90 ID 12 1

44 SAI 2.63 TEH 2.19 Plus Point 90 ID 12 1

44 DOS 0.36 5H 0.07 bobbin 11 12 1

56 SAI 0.15 2H

-0.03 Plus Point 76 OD 12 1

56 DIS 0.4 2H

-0.02 bobbin 8

12 1

87 SAI 2.22 TSH -9.92 Plus Point 59 ID 12 2

1 TWD 11 0.72 IC

-0.2 bobbin 16

=

12 2

10 SAI 1.21 3H

-0.05 Plus Point 31 ID 12 2

10 DIS 0.8 3H

-0.11 bobbin 10

=

12 2

12 DOS 0.41 2H 0.02 bobbin 10 12 2

12 DIS 0.31 3H

-0.04 bobbin 10.

12 2

22 DOS 0.58 6C 0.06 bobbin 14

=

Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind

%TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 12 2

28 SAI 0.78 3H

-0.22 Plus Point 31 ID 12 2

28 SAI 4.12 TEH 1.43 Plus Point 87 ID 12 2

28 DIS 0.41 3H

-0.22 bobbin 1 0 12 2

57 DOS 0.52 3H

-0.13 bobbin 7

12 2

64 DIS 0.72 IH

-0.22 bobbin 8

12 2

64 DOS 0.86 3H 0.02 bobbin 8

12 2

76 SAI 0.49 2H

-0.09 Plus Point 29 ID 12 2

76 DIS 0.9 2H

-0.34 bobbin 8

=

12 2

78 SAI 0.58 IH 0.12 Plus Point 29 ID 12 2

78 DIS 0.5 1H

-0.32 bobbin 8

12 2

79 SAI 0.72 3H 0.08 Plus Point 29 ID 12 2

79 SAI 3.15 TEH 1.53 Plus Point 57 ID 12 2

79 SAI 2.96 TEH 1.98 Plus Point 57 ID 12 2

79 SAI 2.58 TEH 1.45 Plus Point 57 ID 12 2

79 SAI 1.07 TEH 1.44 Plus Point 57 ID 12 2

79 SAI 2.88 TEH 1.44 Plus Point 57 ID 12 2

79 SAI 1.44 TEH 1.44 Plus Point 57 ID 12 2

79 SAI 2.96 TEH 1.46 Plus Point 57 ID 12 2

79, DIS 0.14 3H 0.07 bobbin 7

12 2

90 SAIl 1.65 4H

-0.14 Plus Point 30 ID 12 2

90 SAI 1.16 4H

-0.36 Plus Point 30 ID 12 2

90 SAI 1.13 TEH 1.95 Plus Point 57 ID 12 2

90 SAI 0.84 TEH 1.78 Plus Point 57 ID 12 2

90 SAI 0.93 TEH 0.94 Plus Point 57 ID 12 2

90 SAI 0.93 TEH 1.94 Plus Point 57 ID 12 2

90 SAI 0.7 TEH 1.92 Plus Point 57 ID 12 2

90 SAl 0.44 TEH 0.94 Plus Point 57 ID 12 2

90 SAI 0.77 TEH 0.9 Plus Point 57 ID 12 2

90 SAI 0.7 TEH 0.88 Plus Point 57 ID 12 2

90 SAI 0.37 TEH 0.98 Plus Point 57 ID 12 2

90 DOS 0.47 3H 0.21 bobbin 7

12 2

90 DIS 1.96 4H

-0.17 bobbin 7

12 2

92 SAI 0.54 5H 0.19 Plus Point 30 ID 12 2

92 SAI 0.46 5H

-0.06 Plus Point 30 ID 12 2

92 SAI 0.23 5H

-0.47 Plus Point 30 ID 12 2

92 DIS 0.35 5H 0.26 bobbin 7

12 2

93 SAI 0.42 4H 0.18 Plus Point 30 ID 12 2

93 DIS 0.61 4H

-0.28 bobbin 8

12 3

1 TWD 9

0.58 IC

-0.13 bobbin 17 12 3

18 SAI

=

0.19 6H

-0.28 Plus Point 94 OD 12 3

18 DOS 0.37 6H

-0.28 bobbin 10 12 3

36 SCI 0.53 1H

-0.38 Plus Point 88 OD Plugged SCI-OD @ 1H 12 3

45 DOS _

0.33 2H 0.04 bobbin 11 12 3

46 SAl 0.92 7C 0.08 Plus Point 71 ID Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind

%TW Volts Loc Inch Probe Cal 1010/0 Tube Status Reason for Repair 12 3

50 DOS 0.46 1H 0

bobbin 12 12 3

50 MBI 2.67 5H 25.47 bobbin 12 12 3

56 DOS =

0.23 4H 0.04 bobbin 8

=

12 3

58 DOS =

0.34 4H

.0.13 bobbin 8

=

12 3

59 DOS I 0.66 1H 0.08 bobbin 7

12 3

61 DOS 0.49 1H -0.04 bobbin 7

12 3

62 DOS 0.19 2H 0

bobbin 8

12 3

73 DIS _

1.86 2H

-0.36 bobbin 7

12 3

77 SCI

=

0.37 1H 0.31 Plus Pointl 62 OD Plugged SCI-OD @ IH & 2H 12 3

77 SCI 0.19 2H

-0.14 Plus Point 62 OD Plugged SCI-OD IH&2H 12 3

80 DOS =

1.1 IH 0.19 bobbin 7

=

99 12 3

91 DOS 0.49 2H

-0.07 bobbin 8

12 4

1 TWD 23 1.6 2C 0.02 bobbin 16 12 4

13 FSI 0.31 5H 44.48 bobbin 9

12 4

13 FSI 0.34 5H 25.32 bobbin 9

12 4

47 DOS 0.85 IH 0.04 bobbin 12 12 4

49 DOS 0.51 1H 0.11 bobbin 11 12 4

50 DOS 0.71 2H

-0.15 bobbin 12

=

12. 4 54 SAI =

0.91 2H 0.01 PlusPoint 29 ID 12 4

54 SAI =

2.98 TEH 0.92 Plus Point 91 ID

_._t 12 4

54 DIS 0.49 2H

-0.02 bobbin 8

=

12 4

57 SAI =

0.42 1H 0.06 Plus Point 29 ID 12 4

57 DIS 0.46 1H 0.21 bobbin 7

=

12 4

58 SAI 0.64 IH

-0.29 Plus Point 29 ID 12 4

58 SAI 1.07 IH

-0.21 Plus Point 29 ID 12 4

58 SAI.

2.85 1H 0.15 Plus Point 29 ID 12 4

58 DIS 2.76 1H 0.19 bobbin 8

12 4

70 DOS 0.5 2H

-0.08 bobbin 7

12 4

75 DIS 2.77 3H

-0.28 bobbin 8

12 4

84 SAI 0.5 IH 0.02 Plus Point 30 ID 12 4

84 SAI 2.66 TEH 0.96 Plus Point 57 ID 12 4

84 SAI 1.54 TEH 0.96 Plus Point 57 ID 12 4

84 SAI 1.63 TEH 1.68 Plus Point 57 ID 12 4

84 SAI =

1.95 TEH 0.94 Plus Point 57 ID 12 4

84 SAI 0.86 TEH 0.92 Plus Point 57 ID 12 4

84 SAI 1.12 TEH 0.9 Plus Point 57 ID 12 4

84 SAI 2.39 TEH 0.85 Plus Point 57 ID 12 4

84 SAI 0.68 TEH 1.21 Plus Point 57 ID 12 4

84 SAI 1.35 TEH 1.61 Plus Point 57 ID 12 4

84 SAI 2.07 TEH 1.66 Plus Point 57 ID 12 4

84 DIS =

0.86 1H 0

bobbin 7

12 4

85 SAI =

0.15 3H

-0.14 Plus Point 77 OD 12 4

85 DIS =

0.27 3H

-0.13 bobbin 8

12 4

94 TWD 27 1.87 IC 0.13 bobbin 11 Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 12 4

94 DOS 0.58 1H

-0.19 bobbin 8

12 5

1 VOL 0.21 2C 0.04 Plus Point 78 OD 12 5

1 VOL 0.2 2C 0.08 PIus Point 78 OD 12 5

1 TWD 14 0.89 2C 0.04 bobbin 16

=

12 5

4 TWD 7

0.41 1C

-0.22 bobbin 14 12 5

19 DOS I 1.15 3H

-0.13 bobbin 9

12 5

20 SAI 0.18 6H

-0.06 Plus Point 85 OD 12 5

20 DOS 1.1 2H

-0.2 bobbin 10 12 5

39 SAI 1.01 2H

-0.17 Plus Point 31 ID Plugged SAI-ID/OD @ 2H 12 5

39 SAI 0.24 2H 0.16 Plus Point 31 OD Plugged SAI-ID/OD @ 2H 12 5

39 SAI 3.4 TEH 1.32 Plus Point 89 ID Plugged SAI-ID/OD @ 2H 12 5

39 DIS

=

0.45 2H

-0.2 bobbin 10

=

Plugged SAl-IDIOD @ 2H 12 5

39 DOS.

0.36 2H

-0.09 bobbin 10 Plugged SAI-IDIOD @ 2H 12 5

42 DOS 0.84 4H

-0.07 bobbin 12 12 5

49 SAI 2.96 TEH 1.08 Plus Point 89 ID 12 5

49 DOS 0.7 2H

-0.17 bobbin 11 12 5

50 DOS 0.52 1H

-0.06 bobbin 12 12 5

50 DOS 0.69 3H 0.11 bobbin 12 12 5

51 DOS l

0.95 1H 0

bobbin 7

A 12 5

51 DOS 0.38 3H 0.2 bobbin 7

12 5

52 SAI 0.36 2H 0.04 Plus Point 96 OD 12 5

52 DOS 0.56 2H 0.02 bobbin 8

12 5

53 DOS.

0.29 1H 0.02 bobbin 7

12 5

57 DOS 0.76 1H 0.19 bobbin 7.

12 5

58 DOS

=

0.19 6C

-0.07 bobbin 11 12 5

65 SAI 0.61 1H

-0.15 Plus Point 29 ID 12 5

65 SAI 2.16 TEH 1.12 Plus Point 57 ID 12 5

65 SAI 3.34 TEH 1.03 Plus Point 57 ID 12 5

65 SAI 1.5 TEH 1.42 Plus Point 57 ID 12 5

65 SAI 1.52 TEH 1.73 Plus Point 57 ID 12 5

65 DIS 0.29 1H 0

bobbin 7

12 5

66 SAI 0.78 2H

-0.06 Plus Point 29 ID 12 5

66 SAI 1.88 TEH 0.82 Plus Point 57 ID 12 5

66 SAI I__

1.77 TEH 0.81 Plus Point 57 ID 12 5

66 SAI 1.74 TEH 0.81 Plus Point 57 ID 12 5

66 SAI 0.34 TEH 0.74 Plus Point 57 ID 12 5

66 SAI 2.87 TEH 0.84 Plus Point 57 ID 12 5

66 SAI 1.44 TEH 0.97 Plus Point 57 ID 12 5

66 SAI 0.98 TEH 0.69 Plus Point 57 ID.

12 5

66 SAI 2.34 TEH 1.56 Plus Point 57 ID 12 5

66 DOS 1.26 1H

-0.11 bobbin 8

12 5

66 DIS 1.34 2H

-0.36 bobbin 8

12 5

70 DOS 0.29 2H

-0.06 bobbin 8 =

12 5

70 DOS 0.58 4H

-0.02 bobbin 8 I Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind

%TW Volts Loc Inch Probe Cal ID/OD Tube Status Reason for Repair 12 5

75 DOS 0.6 3H 0.11 bobbin 7

12 5

77 SAI 0.92 5H

-0.22 Plus Point 29 ID 12 5

77 DIS 1.08 5H

-0.08 bobbin 7

12 5

78 SAI 1.17 1H 0.06 Plus Point 29 ID 12 5

78 SAI 1.73 TEH 1.27 Plus Point 57 ID 12 5

78 SAI 0.9 TEH 0.89 Plus Point 57 ID1 12 5

78 SAI 1.38 TEH 0.88 Plus Point 57 ID.

12 5

78 SAI 1.36 TEH 0.88 Plus Point 57 ID 12 5

78 SAI 0.97 TEH 0.9 Plus Point 57 ID 12 5

78 SAI 1.11 TEH 1.16 Plus Point 57 ID 12 5

78 DIS 0.43 1H 0.39 bobbin 8

12 5

91 DOS 0.61 1H

-0.19 bobbin 8

=

12 5

93 SAI 0.77 1H

-0.12 Plus Point 30 ID 12 5

93 SAI 1.42 TEH 1.82 Plus Point 57 ID 12 5

93 SAI 3.11 TEH 0.95 Plus Point 57 ID 12 5

93 SAI 3.34 TEH 0.88 Plus Point 57 ID 12 5

93 SAI 2.47 TEH 1.06 Plus Point 57 ID 12 5

93 SAI 1.3 TEH 0.99 Plus Point 57 ID 12 5

93 SAI 0.88 TEH 0.98 Plus Point 57 ID I 12 5

93 SAI 0.69 TEH 1.01 Plus Point 57. ID!

12 5

93 DIS 0.71 1H -0.15 bobbin 7

12 6

16 DOS 0.6 1H 0.19 bobbin 35 12 6

39 DOS 0.72 1H 0.04 bobbin 38 12 6

49 SAI 0.22 1H

-0.2 Plus Point 90 OD 12 6

49 DIS 0.71 1H -0.19 bobbin 38 12 6

49 DOS 0.52 2H 0.04 bobbin 38 12 6

51 DOS 0.33 2H 0.13 bobbin 30 12 6

54 DOS 1.22 3H 0

bobbin 29 12 6

55 SAI 0.65 7C

-0.03 Plus Point 63 ID 12 6

56 DOS 1.06 2H 0.04 bobbin 30 12 6

58 DOS 0.45 3H 0.06 bobbin 32 12 6

59 DOS 0.29 1H 0.02 bobbin 32 12 6

62 DOS 0.45 1H -0.02 bobbin 32 12 6

62 DOS 0.42 6H

-0.06 bobbin 32 12 6

65 SAI 0.26 2H 0.04 Plus Point 77 OD 12 6

65 DOS 0.43 2H 0.06 bobbin 32 12 6

65 DOS 0.47 4H

-0.04 bobbin 32 12 6

65 DOS 0.49 5H

-0.07 bobbin 32 1 12 6

66 DOS 0.39 4H 0

bobbin 31 12 6

74 SAI 0.68 3H

-0.06 Plus Point 29 ID 12 6

74 SAI 0.37 3H

-0.48 Plus Point 29 ID 12 6

74 DIS 1.5 3H

-0.04 bobbin 30.

12 6

81 SAI 0.2 1H

-0.18 Plus Point 52 0D 12 6 81 DOS 1.06 4H

-0.17 bobbin 29 Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind 0/.TW Volts Loc Inch Probe Cal ID/OD Tube Status Reason for Repair 12 6

87 DOS 0.56 2H

-0.06 bobbin 30 12 6

93 VOL 0.28 IC

-0.17 Plus Point 79 OD 12 6

93 TWD 17 1.14 IC

-0.21 bobbin 31 12 7

2 VOL 0.85 2C

-0.1 Plus Point 78 OD 12 7

2 TWD 37 2.88 2C -0.04 bobbin 35 12 7

4 TWD 10 0.61 IC 0

bobbin 36 12 7

13 DOS 0.84 IH 0.06 bobbin 35 12 7

17 SAM 4.79 TEH 0.69 Plus Point 85 ID 12 7

17 DOS 0.67 1H 0.02 bobbin 35 12 7

31 SAI 0.79 1H _0.05 Plus Point 31 ID 12 7

31 SAI 2.1 7C

-0.2 Plus Point 65 ID 12 7

31 DIS 0.74 1H 0.25 bobbin 37

=

12 7

33 SAI 2.06 TEH 1.64 Plus Point 85 ID 12 7

33 SAI 1.15 TSH -1.91 Plus Point 31 ID I 12 7

49 SAI 0.18 1H -0.06 Plus Point 93 OD 12 7

49 SAI 0.38 IH

-0.05 Plus Point 93 OD 12 7

49 DOS 1.44 1H 0.02 bobbin 37 12 7

52 DOS 0.52 1H -0.02 bobbin 30 12 7

53 SAI 0.77 3H 0

Plus Point !29 ID 12 7

53 SAI 2.13 TEH 1.1 Plus Point 44 ID 12 7

53 SAI 2.67 TEH 1.04 Plus Point 44 ID 12 7

53 SAI 2.59 TEH 1.02 Plus Point 44 ID 12 7

53 SAI 2.69 TEH 0.93 Plus Point 44 ID 12 7

53 SAI 1.99 TEH 1.41 Plus Point 44 ID 12 7

53 DIS 0.5 3H 0.06 bobbin 29

=

12 7

54 DOS 0.66 2H 0.17 bobbin 30 12 7

63 DOS 0.63 3H 0.17 bobbin 31 12 7

65 SAI 0.26 2H 0

Plus Point 47 OD 12 7

65 DIS 0.94 2H

-0.15 bobbin 31 12 7

68 SAI 0.98 3H 0.24 Plus Point 29 ID 12 7

68 SAI 3.47 TEH 0.8 Plus Point 44 ID 12 7

68 SAI 2.51 TEH 1.59 Plus Point 44 ID 12 7

68 SAI 2.98 TEH 0.91 Plus Point 44 ID 12 7

68 SAI 1.79 TEH 1.03 Plus Point 44 ID 12 7

68 SAI 3.11 TEH 1.38 Plus Point 44 ID 12 7

68 SAI 2.15 TEH 1.12 Plus Point 44 ID 12 7

68 DIS 1.19 3H 0.3 bobbin 31 12 7

85 SAI 0.44 1H 0.01 Plus Point 77 OD 12 7

85 DOS 0.82 1H 0

bobbin 30 12 7

94 VOL 0.14 1C -0.15 Plus Point 79 OD 12 7

94 TWD 13 0.83 IC

-0.21 bobbin 31 12 8

4 SAI 1.11 5H

-0.26 Plus Point 93 ID 12 8

4 DIS 0.74 5H

-0.09 bobbin 35

=

12 8

15 SAI 0.93 2H 0.01 Plus Point 31 ID I Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %/oTW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 12 8

15 DIS 0.56 2H 0.04 bobbin 36 12 8

17 SAI 0.16 IH 0.33 Plus Point 84 OD 12 8

17 DIS 0.72 1H 0.3 bobbin 36 12 8

20 SAI

=

0.35 2H

-0.25 Plus Point 84 OD 12 8

20 DOS 1.23 2H

-0.17 bobbin 36 12 8

48 SAI 0.57 IH

-0.15 Plus Point 90 ID 12 8

55 SAI.

1.34 1H -0.09 Plus Point 29 ID 12 8

55 DIS 1.04 IH 0

bobbin 30 12 8

57 SAI 2.21 IH

-0.21 Plus Point 29 ID 12 8

57 DIS 2.51 IH

-0.21 bobbin 31 12 8

61 SAI 0.76 2H 0.12 Plus Point 29 ID 12 8

61 SAI 0.55 2H

-0.04 Plus Point 29 ID 12 8

61 SAI 1.17 2H

-0.21 Plus Point 29 ID l

12 8

61 DIS 1.18 2H

-0.13 bobbin 31 12 8

66 *SAI

=

0.48 2H

-0.28 Plus Point 29 ID 12 8

66 SAI 3.7 TEH 1.08 Plus Point 44 ID 12 8

66 SAI 4

TEH 1.27 Plus Point 44 ID 12 8

66 SAI 3.98 TEH 0.98 Plus Point 44 ID 12 8

66 SAI I__

2.71 TEH 0.85 Plus Point 44 ::ID 12 8

66 SAI 3.25 TEH 0.97 Plus Point 44'* ID 12 8

66 DIS 1.03 2H

-0.23 bobbin 31 12 8

92 TWD 10 0.6 2C

-0.17 bobbin 31 12 8

93 SAI _

0.9 1H -0.17 Plus Point 30 ID 12 8

93 DIS _

0.82 IH

-0.04 bobbin 31

=

12 9

3 TWD 10 0.65 IC

-0.02 bobbin 35 12 9

3 DOS 0.66 3H

-0.02 bobbin 35 12 9

27 SAI

=

0.3 3H

-0.15 Plus Point 31 ID 12 9

27 SAI 2.08 TEH 0.75 Plus Point 85 ID 12 9

27 DIS 0.55 3H

-0.26 bobbin 35 12 9

30 SAI 2.29 1H -0.02 Plus Point 31 ID 12 9

30 SAI 2.06 TEH 1.67 Plus Point 85 ID 12 9

30 DIS 1.49 1H 0.06 bobbin 38 12 9

33 SAI 0.15 1H 0.05 Plus Point 82 OD 12 9

38 SAI 2.53 2H

-0.12 Plus Point 31 ID 12 9

38 SAI 1.59 TEH 1.49 Plus Point 85 ID 12 9

38 DIS 1.69 2H

-0.13 bobbin 37 12 9

45 SAI 1.27 IH 0.16 Plus Point 31 ID 12 9

45 SAI 1.76 TEH 1.39 Plus Point 85 ID 12 9

45 DIS 0.61 IH 0.21 bobbin 37

=

12 9

53 SAI 1.26 IH 0.06 Plus Point 29 ID 12 9

53 SAI 2.84 TEH 1.18 Plus Point 44 ID 12 9

53 SAI 2.07 TEH 1.27 Plus Point 44 ID 12 9

53 SAI 2.06 TEH 1.03 Pius Point 44 ID 12 9

53 SAI 1.96 TEH 1.59 Plus Point 44 ID Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind

%/eTW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 12 9

53 SAI 2.59 TEH 1.02 Plus Point 44 ID 12 9

53 DIS 0.69 1H 0.13 bobbin 30 12 9

56 SAI 1.05 1H -0.28 Plus Point 29 ID 12 9

56 DIS 1.66 1H -0.35 bobbin 7

12 9

58 DOS 1.25 2H

-0.11 bobbin 31 12 9

82 SA_

1.4 3H 0.17 Plus Point 30 ID 12 9

82 SAI 1.3 TEH 0.79 Plus Point 44 ID 12 9

82 SAI 2.88 TEH 0.93 Plus Point 44 ID 12 9

82 SAI 0.92 TEH 1.05 Plus Point 44 ID 12 9

82 DIS 1.56 3H 0.15 bobbin 56 12 9

92 TWD 17 1.15 2C

-0.11 bobbin 11 12 10 3 VOL 0.35 2C

-0.02 Plus Point 78 OD 12 10 3 TWD 8

0.52 2C

-0.08 bobbin 36 12 10 32 DOS 0.53 1H 0.02 bobbin 38 12 10 41 SAI I 0.36 2H 0

Plus Point 80 OD 12 10 41 DOS 1.2 2H 0.04 bobbin 38 12 10 43 SAI

=

0.32 1H 0

Plus Point 79 OD 12 10 43 DIS 0.49 1H

-0.3 bobbin 38 12 10 43 DOS 0.44 2H

-0.19 bobbin 38

____e 12 10 45 SAH'j 0.17 2H

-0.03 Plus Point 90 OD 12 10 45 DIS 1.15 2H

-0.11 bobbin 38 12 10 49 SAII 0.78 3H 0.17 Plus Point 31 ID 12 10 49 SAI 2.77 TEH 1.56 Plus Point 89 ID 12 10 49 DIS 0.24 3H 0.27 bobbin 38 12 10 49 DIS 1.01 3H

-0.13 bobbin 38 12 10 52 DOS

__0.65 2H 0.22 bobbin 29 12 10 58 DOS 0.9 4H 0.09 bobbin 32

=

12 10 62 SAI

=

1.13 1H 0.02 Plus Point 29 ID 12 10 62 SAI

=

2.92 TEH 1.23 Plus Point 44 ID 12 10 62 SAI 1.73 TEH 1.08 Plus Point 44 ID 12 10 62 SAI 2.15 TEH 1.08 Plus Point 44 ID 12 10 62 SAI

=

1.72 TEH 1.36 Plus Point 44 ID 12 10 62 SAI 1.98 TEH 1.7 Plus Point 44 ID 12 10 62 SAI 3.96 TEH 1.25 Plus Point 44 ID 12 10 62 SAI 2.21 TEH 1.43 Plus Point 44 ID 12 10 62 DIS I__

0.57 1H 0.09 bobbin 32 12 10 64 DOS 0.67 1H

-0.04 bobbin 32 12 10 66 DOS 0.26 2H 0.11 bobbin 32 12 10 67 SAl 0.82 1H -0.22 Plus Point 29 ID 12 10 67 SAI

=

5.38 TEH 1.01 Plus Point 44 ID 12 10 67 SAI 2.91 TEH 1.7 Plus Point 44 ID 12 10 67 SAI 4.17 TEH 1

Plus Point 44 ID 12 10 67 DIS 0.28 1H -0.17 bobbin 31 12 10 68 SAI _

1.47 1H -0.12 Pius Point 29 ID II Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 12 10 68 DIS 0.94 1H -0.06 bobbin 32 12 10 69 SAI 0.54 2H

-0.21 Plus Point 29 ID 12 10 72 DOS 0.94 2H

-0.13 bobbin 29 12 10 80 SAI 0.61 1H -0.24 Plus Point 30 ID 12 10 81 SAI 0.33 1H -0.16 Plus Point 77 OD 12 10 81 DOS 0.49 1H -0.09 bobbin 30 12 10 85 SAI

=

0.56 4H 0.24 Plus Point 30 ID 12 10 85 SAI

=

2.14 TEH 0.77 Plus Point 44 ID 12 10 85 SAI 2.13 TEH 0.77 Plus Point 44 ID 12 10 85 SAI

=

0.9 TEH 0.78 Plus Point 44 ID 12 10 85 SAI 2.25 TEH 1.82 Plus Point 44 ID 12 10 85 SAI 0.76 TEH 0.72 Plus Point 44 ID 12 10 85 DIS 0.35 4H 0.28 bobbin 29 12 11 18 SAI 0.23 2H

-0.27 Plus Point 83 OD I 12 11 20 SAI 1.62 2H 0.05 Plus Point 31 ID 12 11 20 SAI _

1.48 TEH 1.49 Plus Point 85 ID 12 11 20 DIS 1.26 2H 0.11 bobbin 35

=

12 11 34 DOS 0.51 1H 0.06 bobbin 37

=

12 11 40 SAI ____

0.28 1H -0.07 Plus Point 79 OD I2 e.2 12 11 45 SAI 1.08 1H 0.18 Plus Point 31 ID 12 11 45 DIS 5.02 1H -0.23 bobbin 37 12 11 58 DOS 0.69 1H 0

bobbin 31 12 11 60 DOS 0.59 6H 0

bobbin 31 12 11 64 DOS I_

1 1

H 0.11 bobbin 31 12 11 66 SAI 0.96 3H

-0.07 Plus Point 29 ID 12 11 66 DIS 0.79 3H 0

bobbin 31 12 11 71 SAI 1.27 1H -0.23 Plus Point 29 ID 12 11 71 SAI 1.45 1H -0.11 Plus Point 29 ID 12 11 71 SAI 0.54 1H 0.06 Plus Point 29 ID I

12 11 71 SAI 0.39 1H 0.12 Plus Point 29 ID 12 11 71 SAI 2.03 TEH 0.97 Plus Point 44 ID 12 11 71 SAI 1.56 TEH 1.07 Plus Point 44 ID 12 11 71 SAI 0.85 TEH 1.16 Plus Point 44 ID 12 11 71 DIS 1.99 1H -0.13 bobbin 30 12 11 75 SAI 0.22 2H

-0.2 Plus Point 49 OD 12 11 75 DIS 2.46 2H

-0.17 bobbin 29 12 11 82 DOS 0.57 2H

-0.06 bobbin 30 12 11 84 SAI 0.85 2H

-0.2 Plus Point 30 ID 12 11 87 SAI 2.02 1H -0.06 Plus Point 30 ID 12 11 87 DIS 1.91 1H -0.06 bobbin 30

=

12 11 93 TWD 18 1.16 2C

-0.11 bobbin 31 12 12 3

TWD 10 0.65 1C 0

bobbin 36 12 12 4

TWD 8

0.5 1C -0.11 bobbin 35 12 12 21 1DIS 0.45 4H

-0.19 bobbin 36 Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 12 12 35 DOS 0.49 11H 0.06 bobbin 37 12 12 46 SAI 0.23 2H

-0.02 Plus Point 94 OD 12 12 46 DOS 0.62 2H

-0.02 bobbin 38 12 12 55 DOS 0.39 2H 0

bobbin 29 12 12 63 DOS 0.81 1H

-0.15 bobbin 32

=

12 12 65 SAI 0.19 2H 0.22 Plus Point 48 OD 12 12 65 DOS 0.62 2H 0.31 bobbin 32

=

12 12 69 DOS 0.37 1H 0.02 bobbin 32.

12 12 76 SAI 0.1 1H

-0.18 Plus Point 50 OD 12 12 77 SAI 1.35 1H

-0.1 Plus Point 29 ID Plugged SAI-ID/OD c1 1H 12 12 77 SAI 0.2 1H

-0.17 Plus Point 29 OD Plugged SAI-IDNOD cD 1H 12 12 77 SAI 0.15 1H 0.07 Plus Point 29 OD Plugged SAI-ID/OD@ 1H 12 12 77 SAI 0.81 TEH 1.67 Plus Point 44 ID Plugged SAI-ID/OD @ 1H 12 12 77 SAI 0.65 TEH 1.78 Plus Point 44 ID Plugged SAI-IDIOD @ 1H 12 12 77 DIS

=

1.27 H

0.02 bobbin 29

=

Plugged SAI-IDIOD @ 1H 12 12 83 SAI 0.49 2H 0

Plus Point 77 OD 12 12 83 DOS 1.34 2H 0.11 bobbin 29

=

12 12 93 DOS 0.95 2H 0.04 bobbin 31 12 13 3

TWD

11 0.66 IC

-0.06 bobbin 35 12 13 6

TWD 21 1.4 2C

-0.06 bobbin 35 12 13 10 SAI 1.17 1H

-0.4 Plus Point 31 ID Plugged SAl-ID @1H, DOP>=40%TW 12 13 10 DIS 3.54 1 H

-0.3 bobbin 35 Plugged SAl-ID

-1H.

DOP>=40%TW 12 13 34 SAI 1.1 1H 0.11 Plus Point 31 ID 12 13 34 SAI 0.17 3H

-0.29 Plus Point 94 OD 12 13 34 SAI 1.5 TEH 1.04 Plus Point 85 ID 12 13 34 DIS I 1 H 0.19 bobbin 37

=

12 13 34 DOS 0.44 2H 0.11 bobbin 37 12 13 34 DOS 0.89 3H

.0.19 bobbin 37

=

12 13 41 IDOS 0.57 5H 0

bobbin 37 12 13 44 SAI 1.87 I 1H 0.02 Plus Point 31 ID 12 13 44 SAI 1.59 TEH 1.38 Plus Point 85 ID 12 13 44 SCI 2.28 TEH 1.27 Plus Point 85 ID 12 13 44 DIS 1.98 1H 0.02 bobbin 37 12 13 51 DOS 1.34 1H 0.09 bobbin 30 12 13 52 DOS 0.28 1 H 0.04 bobbin 30 12 13 52 DOS 0.27 2H 0.06 bobbin 30 12 13 53 DOS 0.24 5C

-0.06 bobbin 30 12 13 56 SAI 2.78 1H

-0.03 Plus Point 96 OD Plugged SAI-OD, >2v DOS 0 1H 12 13 56 DOS 3.08 1H 0.02 bobbin 41

=

Plugged SAI-OD, >2v DOS @ 1H 12 13 60 SAI 1.39 2H

-0.02 Plus Point 29 ID 12 13 60 SAI 2.7 TEH 0.95 Plus Point 44 ID 12 13 60 SAI 1.84 TEH 1.34 Plus Point 44 ID 12 13 60 SAI 3.47 TEH I

Plus Point 44 ID 12 13 60 SAl 2.18 TEH 0.78 Plus Point 44 ID Enclosure PG&E Letter DCL-05-028 V

Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 12 13 60 SAI 3.6 TEH 0.92 Plus Point 44 ID 12 13 60 SAI

=

1.88 TEH 1.44 Plus Point 44 ID 12 13 60 SAI 2.99 TEH 1.1 Plus Point 44 ID 12 13 60 DIS

=

0.8 2H 0.09 bobbin 31 12 13 66 SAI

=

0.22 2H 0.29 Plus Point 48 OD 12 13 73 DOS 0.27 3H 0.04 bobbin 30 12 13 76 DOS 1.02 2H

-0.02 bobbin 30 12 13 82 SAI

=

0.28 SH

-0.21 Plus Point 77 OD 12 13 82 DOS I__

0.88 5H

-0.13 bobbin 30 12 13 83 SAI 0.12 3H 0.18 Plus Point 77 OD 12 13 83 SAI 0.18 3H

-0.3 Plus Point 77 OD 12 13 83 SAI 0.21 5H

-0.31 Plus Point 51 OD 12 13 83 SAI

=

0.15 5H

-0.19 Plus Point 51 OD 12 13 83 SAI

=

1.01 TEH 0.95 Plus Point 44 ID 12 13 83 DOS 0.25 1H 1 -0.04 bobbin 30 12 13 83 DOS 1.02 3H

-0.19 bobbin 30 12 13 83 DOS

=

0.77 5H

-0.19 bobbin 30 12 13 84 SAI 0.51 1H 0.01 Plus Point 30 ID 12 13 84 SAI I__

0.27 1H

-0.01 Plus Point 30 ID 12 13 84 SAI 0.24 2H 0.33 Plus Point 52 OD 12 13 84 DIS 0.39 1H 0.06 bobbin 30 12 13 84 DOS 0.32 2H 0.26 bobbin 30 12 13 84 DOS 0.35 6C

-0.11 bobbin 30 12 13 87 DOS 0.62 2H 0.02 bobbin 30 12 13 90 DOS

=

0.81 3H

-0.02 bobbin 30 12 13 92 TWD 9

0.54 2C

-0.09 bobbin 32 12 14 5

TWD 10 0.64 2C

-0.19 bobbin 21 12 14 7

SAI

=

0.18 2H 0.06 Plus Point 89 OD 12 14 16 SAI 0.68 4H

-0.01 Plus Point 31 ID 12 14 16 DIS 0.51 4H

-0.06 bobbin 22 12 14 19 DOS 0.41 1H 0.04 bobbin 24 12 14 23 DOS 0.25 2H

-0.15 bobbin 23

=

12 14 27 DOS 1.09 1H 0.07 bobbin 26 12 14 28 SCI 0.41 1H

-0.25 Plus Point 82 OD Plugged SCI-OD @ 1H 12 14 30 SAI 0.36 2H

-0.02 Plus Point 82 OD 12 14 30 DOS 1.23 2H

-0.04 bobbin 26 12 14 31 DOS 0.35 3H

-0.07 bobbin 26 12 14 36 DOS 0.47 2H 0.28 bobbin 26 12 14 37 DOS 0.72 2H 0

bobbin 26 12 14 43 DOS 1.3 1 H 0.26 bobbin 33

=

12 14 45 SAI 0.43 1H 0.02 Plus Point 31 ID

.12 14 45 DIS 1.02 1H

-0.2 bobbin 34 12 14 48 DOS 0.9 1H

-0.04 bobbin 34

=

12 14 52 DOS 0.74 2H 0.1 bobbin 27 _

Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 12 14 58 SAI _

0.53 4H 0.18 Plus Point 46 ID 12 14 68 SAI 0.71 1H -0.07 Plus Point 29 ID 12 14 68 SAI 2.51 TEH 0.81 Plus Point 44 ID 12 14 68 SAI 1.78 TEH 0.83 Plus Point 44 ID 12 14 68 SAI 1.93 TEH 0.79 Plus Point 44 ID 12 14 68 SAI 1.42 TEH 0.98 Plus Point 44 ID 12 14 68 SAI

=

1.21 TEH 0.9 Plus Point 44 ID 12 14 68 SAI 0.39 TEH 1.16 Plus Point 44 ID 12 14 68 SAI 1.72 TEH 1.4 Plus Point 44 ID 12 14 68 SAI 3.01 TEH 1.47 Plus Point 44 ID 12 14 70 SAI 0.27 1H

-0.04 Plus Point 29 ID 12 14 70 SAI 1.68 TEH 0.71 Plus Point 44 ID 12 14 70 SAI.

1.7 TEH 0.76 Plus Point 44 ID 12 14 70 SAI 1.43 TEH 1.07 Plus Point 44 ID 12 14 70 DIS 3.74 1H

-0.2 bobbin 22 12 14 74 SAI 1.01 1H -0.13 Plus Point 29 ID 12 14 74 SAI 1.74 TEH 0.96 Plus Point 44 ID 12 14 74 SAI 0.88 TEH 0.83 Plus Point 44 ID 12 14 74 SAI 1.26 TEH 0.81 Plus Point 44 ID 12 14 74 SAI 1.51 TEH 0.75 Plus Point 44 ID 12 14 74 SAI 1.06 TEH 1.8 Plus Point 44 ID 12 14 74 SAI 1.17 TEH 1.79 Plus Point 44 ID 12 14 74 SAI.

0.69 TEH 1.79 Plus Point 44 ID 12 14 74 DIS 5.34 1H -0.08 bobbin 23 12 14 76 SAI 0.42 1H 0.03 Plus Point 50 OD 12 14 76 SAI 0.16 1H 0.24 Plus Point 50 OD 12 14 76 DOS 0.58 1H 0.02 bobbin 25 12 14 84 SAI 0.21 2H 0.27 Plus Point 51 OD 12 14 91 TWD 16 1.04 1C -0.15 bobbin 25 12 15 5 TWD 17 1.09 2C

-0.13 bobbin 22 12 15 26 DOS 0.59 1H 0.08 bobbin 33 12 15 32 SAI 0.27 2H 0.03 Plus Point 93 OD 12 15 32 DOS 0.57 2H 0.04 bobbin 26 12 15 35 SAI 0.35 1H 0.02 Plus Point 93 OD 12 15 35 SAI 0.2 1H

-0.09 Plus Point 93 OD 12 15 35 DOS 0.79 1H 0.02 bobbin 26 12 15 35 DOS 0.24 SH

-0.02 bobbin 26 12 15 42 SAl 0.27 2H 0.04 Plus Point 93 OD 12 15 74 SAI 0.34 1H

-0.07 Plus Point 49 OD 12 15 74 DOS 1.66 1H 0.06 bobbin 23 12 15 76 DOS 0.71 1H -0.04 bobbin 25 12 15 80 DOS 0.45 1H 0.09 bobbin 24 12 15 92 VOL 0.5 2C

-0.06 Plus Point 79 CD 12 15 92 DOS 0.4 1H 0.04 bobbin 26 Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %7W Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 12 15 92 TWD 10 0.59 2C -0.06 bobbin 26 12 16 9

DIS 0.51 4H

-0.06 bobbin 22 12 16 12 SAI 0.46 5H

-0.07 Plus Point 31 ID 12 16 12 DIS 0.46 5H

-0.26 bobbin 22 12 16 21 DOS 0.86 1H 0.13 bobbin 24

=

12 16 30 SAI 0.2 2H

-0.19 Plus Point 94 OD 12 16 30 DOS

=

0.73 2H

-0.19 bobbin 26

=

12 16 33 SAI 0.42 2H

-0.01 Plus Point 94 OD 12 16 33 DOS 0.39 1H -0.06 bobbin 26 12 16 33 DOS 1.12 2H

-0.07 bobbin 26 12 16 40 SAI 0.8 2H

-0.04 Plus Point 80 OD 12 16 40 DOS 1.33 2H

-0.02 bobbin 27 12 16 44 DIS 0.48 4H 0.04 bobbin 34 12 16 52 DOS 0.6 2H

-0.04 bobbin 27 12 16 55 DOS 0.59 1H -0.04 bobbin 27

=

12 16 59 SAI 2.3 2H 0.04 Plus Point 29 ID 12 16 59 DIS 0.31 2H

-0.23 bobbin 26 12 16 59 DIS 2.13 2H 0.06 bobbin 26 12 16 60 SAI 0.38 2H

-0.2 Plus Point 47 ID 12 16 82: SAI 0.62 1H 0.06 Plus Point 30 ID 12 16 82 SAI 0.82 4H 0.08 Plus Point 30 ID 12 16 82 SAI 1.9 TEH 1.74 Plus Point 44 ID 12 16 82 SAI 2.38 TEH 1.52 Plus Point 44 ID 12 16 82 SAI 1.27 TEH 1.54 Plus Point 44 ID 12 16 82 SAI 1.42 TEH 1.32 Plus Point 44 ID 12 16 82 SAI 1.12 TEH 1.08 Plus Point 44 ID 12 16 82 DIS

=

0.74 1H 0.13 bobbin 25

=

12 16 82 DIS 1.03 4H

-0.21 bobbin 25 12 16 85 SAI 0.62 2H

-0.28 Plus Point 30 ID 12 16 85 SAI 1.08 TEH 0.88 Plus Point 44 ID 12 16 85 SAI 1.09 TEH 0.88 Plus Point 44 ID 12 16 85 SAI 0.39 TEH 0.88 Plus Point 44 ID 12 16 85 SAI.

2.03 TEH 0.89 Plus Point 44 ID 12 16 85 SAI.

0.3 TEH 14A2 Plus Point 44 ID 12 16 85 SAI 0.67 TEH 1.44 Plus Point 44 ID 12 16 85 SAI 1.11 TEH 1.71 Plus Point 44 ID 12 16 85 SAI 1.23 TEH 1.71 Plus Point 44 ID 12 16 85 DIS 0.54 2H

-0.21 bobbin 25 12 16 87 SAI 1.11 2H 0.02 Plus Point 30 ID 12 16 87 SAI 0.75 TEH 1.3 Plus Point 44 ID 12 16 87 SAI 0.53 TEH 1.31 Plus Point 44 ID I 12 16 87 SAI 0.62 TEH 1.46 Plus Point 44 ID 12 16 87 SAI 0.34 TEH 1.47 Plus Point 44 ID 12 16 87 SAI 0.46 TEH 1.6 Plus Point 44 ID Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind l%Wrl Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 12 16 87 SAI 0.34 TEH 1.74 Plus Point 44 ID 12 16 87 DIS 1.03 2H 0.11 bobbin 25 12 16 88 SAI 1.16 2H

-0.03 Plus Point 30 ID 12 16 88 SAI 0.54 TEH 1.16 Plus Point 44 ID 12 16 88 SAI 0.69 TEH 1.45 Plus Point 44 ID 12 16 88 SAI 0.21 TEH 1.61 Plus Point 44 ID 12 16 88 SAI 0.5 TEH 1.72 Plus Point 44 ID 12 16 88 DIS 1.39 2H 0.02 bobbin 25 12; 16 90 DOS 0.81 1H 0.06 bobbin 25 12 17 9

SAI 0.66 6H

-0.09 Plus Point 31 ID 12 17 9

SAI 2.34 TEH 1.34 Plus Point 85 ID 12 17 9

DIS 0.17 6H

-0.11 bobbin 21 12 17 16 SAI 0.17 3H

-0.28 Plus Point 93 OD 12 17 16 DOS 0.45 3H

-0.28 bobbin 21

=

12 17 24 SAI 0.19 1H 0.01 Plus Point 93 OD 12 17 24 DOS 0.76 1H

-0.11 bobbin 23

=

12 17 38 DOS 0.71 2H

-0.06 bobbin 26

=

12 17 44 SAI 0.27 1H

-0.21 Plus Point 93 OD 12 17 44 DOS 0.71 1H

-0.21 bobbin 33 12 17 45 SCI 0.25 1H 0.25 Plus Point 89 OD Plugged SCI-ODMAONDB @ 1H 12 17 45 SAI 0.24 1H

-0.06 Plus Point 89 OD Plugged SCI-OD/AONDB @ 1 H 12 17

  • 45 DIS 1.29 1H -0.19 bobbin 33 Plugged SCI-OD/AONDB @ 1IH 12 17 47 SAI 1.75 1H

-0.02 Plus Point 93 OD Plugged SAI-OD, >2v DOS @ 1H 12 17 47 DOS 2.35 1H

-0.02 bobbin 33 Plugged SAI-OD, >2v DOS @ 1H 12 17 50 DOS 0.98 2H

-0.02 bobbin 27 12 17 54 SAI 1.75 1H 0.09 Plus Point 29 ID 12 17 54 DIS 1.25 1H 0.09 bobbin 26 12 17 57 DIS 0.74 1H 0.04 bobbin 27 12 17 57 DOS 0.23 2H 0.06 bobbin 27 12 17 57 DOS 0.3 3H 0.02 bobbin 27 12 17 59 SAI 1.69 1H 0.1 Plus Point 29 ID 12 17 59 SAI 1.32 TEH 1.54 Plus Point 44 ID 12 17 59 SAI 1.02 TEH 0.88 Plus Point 44 ID 12 17 59 SAI 1.47 TEH 1.55 Plus Point 44 ID 12 17 59 SAI 2.24 TEH 1.05 Plus Point 44 ID 12 17 59 SAI 1.25 TEH 1.53 Plus Point 44 ID 12 17 59 DIS 1.91 1H 0.15 bobbin 27 12 17 66 SAI 2.3 1H -0.04 Plus Point 29 ID 12 17 66 SAI 2.85 TEH 0.99 Plus Point 44 ID 12 17 66 SAI 2.31 TEH 0.93 Plus Point 44 ID 12 17 66 SAI 1.32 TEH 0.93 Plus Point 44 ID 12 17 66 SAI 2.04 TEH 0.94 Plus Point 44 ID 12 17 66 SAI 2.7 TEH 0.92 Plus Point 44 ID 12 17 66 SAI 1.65 TEH 1.48 Plus Point 44 ID II Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW IVolts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 12 17 66 DIS

=

1.06 IH 0.08 bobbin 26

= I 12 17 67 SAI 0.89 IH

-0.3 Plus Point 29 ID 12 17 67 SAI 2.63 TEH 1.2 PIus Point 44 ID 12 17 67 SAI 2.8 TEH 1.43 PIus Point 44 ID 12 17 67 SAI

=

1.4 TEH 0.85 Plus Point 44 ID X

12 17 67 SAI 1.03 TEH 0.79 PIus Point 44 ID 12 17 67 SAI

=

1.7 TEH 0.79 PIus Point 44 ID 12 17 67 SAI 2.4 TEH 1.51 Plus Point 44 ID 12 17 67 SAI

=

1.83 TEH 0.96 Plus Point 44 ID I 12 17 67 DIS 1.35 IH

-0.28 bobbin 26 12 17 67 DOS 0.38 4H -0.02 bobbin 26 12 17 68 SAI 0.28 1H -0.12 Plus Point 76 OD 12 17 68 DOS 0.15 1H 0

bobbin 28 12 17 69 DOS 0.25 2H 0.02 bobbin 23 12 17 79 SAI 0.2 IH 0.31 PIus Point 77 OD 12 17 79 DOS 0.49 IH 0.34 bobbin 25 12 17 88 SAI 0.59 2H 0.16 PIus Point 30 ID 12 17 88 SAI 1.6 TEH 1.94 Plus Point 43 ID 12 17 88 SAI 0.59 TEH 1.67 Plus Point 43 ID 12 17 88 SAI 0.35 TEH 1.66 Plus Point 43 ID 12 17 88 SAI 0.59 TEH 1.92 PIus Point 43 ID 12

  • 17 88 SAI 0.53 TEH 2.04 PIus Point 43 ID 12 17 88 DIS 0.55 2H

-0.2 bobbin 24 12 18 22 SAI 0.16 1H 0.17 PIus Point 83 OD I 12 18 38 DOS 0.74 2H

-0.24 bobbin 26

=

12 18 40 DOS 0.99 IH

-0.02 bobbin 27 12 18 40 DOS 0.21 2H

-0.06 bobbin 27 12 18 51 DOS 0.27 2H 0.06 bobbin 26 12 18 54 DOS 0.4 3H

-0.21 bobbin 27 12 18 63 TWD 20 0.39 7H 37 bobbin 27 12 18 63 TWD 21 0.41 7H 49.33 bobbin 27 12 18 64 SAI 0.55 3H

-0.16 Plus Point 29 ID 12 18 64 SAI 1.79 TEH 0.78 Plus Point 44 ID 12 18 64 SAI 2.2 TEH 0.94 Plus Point 44 ID 12 18 64 SAI 1.3 TEH 0.95 PIus Point 44 ID 12 18 64 SAI 3.13 TEH 0.88 Plus Point 44 ID 12 18 64 SAI 1.49 TEH 0.98 PIus Point 44 ID 12 18 64 SAI 1.23 TEH 0.8 PIus Point 44 ID 12 18 64 SAI

=

1.34 TEH 1.61 PIus Point 44 ID 12 18 64 SAI 0.74 TEH 1.55 Plus Point 44 ID 12 18 64 DIS 0.84 3H

-0.17 bobbin 27 12 18 84 DOS 0.18 1H 0.08 bobbin 25 12 16 86 DOS 0.5 IH 0.02 bobbin 25 12 18 89 DOS 0.56 2H

-0.04 bobbin 25 Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind

/.TW Volts Loc Inch Probe Cal ID/OD Tube Status Reason for Repair 12 19 31 SAI 1.16 1H 0

Plus Point 93 OD 12 19 31 SAI 0.46 4H

-0.02 Plus Point 31 ID 12 19 31 DOS 1.86 1H 0.02 bobbin 56 12 19 31 DIS 0.98 4H

-0.15 bobbin 26 12 19 32 DOS

=

0.45 1 H

-0.08 bobbin 26

=

12 19 33 DOS 0.34 2H

-0.02 bobbin 26

=

12 19 34 SAI 2.58 2H 0.17 Plus Point 31 ID 12 19 34 SAI 3.51 TEH 1.47 Plus Point 85 ID 12 19 34 DIS 1.5 2H 0.15 bobbin 26 12 19 36 SAI 0.24 2H 0.01 Plus Point 93 OD 12 19 36 DOS 0.32 2H 0.04 bobbin 26.

12 19 39 DOS 0.63 2H 0

bobbin 27 12 19 39 TWD 19 0.33 7H 35.56 bobbin 27

=

12 19 41 SAI

=

0.78 1H

-0.11 Plus Point 94 OD 12 19 41 DOS 1.5 1H

-0.11 bobbin 27 12 19 41 DOS 1.02 2H

-0.28 bobbin 27 12 19 48 SAI 0.25 1H 0.34 Plus Point 93 OD 12 19 48 DOS 0.62 1 H 0.34 bobbin 33 12 19 57 SAI 0.29 2H

-0.07 Plus Point 45 *OD 12 19 57 SAI 0.21 2H 0.28 Plus Point 45 D

OD 12 19 65 DOS 0.5 2H 0.02 bobbin 26 12 19 67 TWD 27 0.77 7H 35.71 bobbin 26.

12 19 67 TWD 18 0.37 7H 37.31 bobbin 26 12 19 67 TWD 27 0.78 7H 50.08 bobbin 26

=

12 19 67 TWD 22 0.51 7H 51.12 bobbin 26

=

12 19 67 TWD 23 0.56 7H 61.82 bobbin 26 12 19 70 DOS 0.38 1H 0.02 bobbin 23 12 19 71 SCI 0.18 4H 0.32 Plus Point 49 OD Plugged SCI-OD @ 4H 12 19 74 SAI 0.57 2H

-0.11 Plus Point 29 ID 12 19 74 DIS 0.19 2H

-0.06 bobbin 39 12 19 79 SAI 0.19 1H

-0.1 Plus Point 77 OD 12 19 79 SAI 0.23 1H 0.29 Plus Point 77 OD 12 19 79 DOS 0.68 1H 0.3 bobbin 25 12 19 85 SAI 0.11 1H 0

Plus Point 77 OD Plugged SAI-OD, >2v DOS @ 2H 12 19 85 SAI 0.49 2H

-0.12 Plus Point 51 OD Plugged SAI-OD, >2v DOS @ 2H 12 19 85 SAI 0.18 2H 0.05 Plus Point 51 OD Plugged SAI-OD, >2v DOS @ 2H 12 19 85 DOS 0.31 1H

-0.54 bobbin 56 Plugged SAI-OD, >2v DOS @ 2H 12 19 85 DOS 2.59 2H

-0.11 bobbin 56_

Plugged SAI-OD >2v DOS @ 2H 12 19 89 TWD 10 0.63 2C

-0.15 bobbin 24 12 20 21 DOS 0.47 1 H 0

bobbin 24 12 20 37 SAI 2.17 TEH 1.7 Plus Point 85 ID 12 20 37 SAI 1.92 TSH -1.68 Plus Point 31 ID 12 20 40 SAI 0.93 TEH 1.53 Plus Point 85 ID 12 20 40 DOS 0.36 1 H 0.07 bobbin 27

=

I 4I Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind

%TW Volts Loc Inch Probe Cal ID/OD Tube Status Reason for Repair 12 20 43 SAI 6.01 TEH 0.98 Plus Point 85 ID 12 20 43 DOS 1.1 I H

-0.04 bobbin 27 12 20 43 DOS 1.03 3H

-0.24 bobbin 27 12 20 44 SAI _

0.14 1H

-0.45 Plus Point 93 OD Plugged SAI-OD, >2v DOS @ 1H 12 20 44 SAI 0.35 1H

-0.11 Plus Point 93 OD Plugged SAI-OD, >2v DOS

- 1H 12 20 44 SAI 0.38 1H -0.07 Plus Point 93 OD Plugged SAI-OD, >2v DOS 1H 12 20 44 SAI 0.48 1H

-0.03 Plus Point 93 OD Plugged SAI-OD, >2v DOS @ 1H 12 20 44 SAI 0.31 1H

-0.01 Plus Point 93 OD Plugged SAI-OD, >2v DOS @ IH 12 20 44 DOS I 2.35 1H

-0.02 bobbin 27 Plugged SAI-OD, >2v DOS @ IH 12 20 48 SAI 0.64 3H

-0.12 Plus Point 31 ID 12 20 48 DIS 0.14 3H 0.11 bobbin 33 12 20 51 SAI 0.26 1H

-0.12 Plus Point 76 OD 12 20 51 SAI 0.29 1H

-0.04 Plus Point 76 OD 12 20 51 DOS 0.79 1H 0.06 bobbin 27

=

12 20 54 SAI 0.31 1H 0.04 Plus Point 46 OD 12 20 54 DOS 0.5 1H 0.11 bobbin 27 12 20 54 DOS 0.37 3H 0.04 bobbin 27 12 20 55 DOS 0.96 2H

-0.13 bobbin 27 12 20 63 DOS 1.9 2H

-0.17 bobbin 27 12 20 72 SAI 0.16 1H

-0.09 Plus Point 49 OD 12 20 72 DOS 1.08 1H

-0.12 bobbin 37.

12 20 77 SAI 1.11 1H 0.01 Plus Point 29 ID 12 20 77 SAI _

1.28 TEH 0.86 Plus Point 44 ID 12 20 77 SAI _I_

2.77 TEH 1.04 Plus Point 44 ID 12 20 77 SAI 3.44 TEH 1.05 Plus Point 44 ID 12 20 77 SAI

=

1.27 TEH 0.99 Plus Point 44 ID 12 20 77 SAI 2.1 TEH 1.79 Plus Point 44 ID 12 20 77 DIS 0.61 1H 0.02 bobbin 25 12 20 83 SAI 0.17 1H

-0.23 Plus Point 52 OD 12 20 83 SAI 0.26 1H

.0.07 Plus Point 52 OD 12 20 83 DIS 1.99 1H

-0.13 bobbin 25 12 20 83 DOS 0.58 3H 0.04 bobbin 25

=

12 20 88 TWD 7

0.42 2C 0.31 bobbin 25 12 20 89 DOS 1.15 3H 0.1 bobbin 25 12 21 17 DOS 0.25 2H

-0.08 bobbin 21 12 21 19 DOS 0.75 2H

-0.11 bobbin 23 12 21 21 SAI 0.19 1H

-0.21 Plus Point 83 OD 12 21 21 DOS 0.52 1H

-0.21 bobbin 23

=

12 21 28 DOS 0.2 2H

-0.06 bobbin 26 12 21 30 DOS 0.91 2H

-0.07 bobbin 26 12 21 32 SAI 0.23 1H 0.13 Plus Point 81 OD 12 21 32 DOS 0.6 1H 0.22 bobbin 26 12 21 38 SAI 2

1H

-0.04 Plus Point 31 ID 12 21 38 SAI 0.84 TEH 1.72 Plus Point 85 ID Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %/*TW Volts Loc Inch Probe Cal ID/OD Tube Status Reason for Repair 12 21 38 DIS 1.79 1H -0.06 bobbin 26 12 21 44 DOS 0.5 1H -0.11 bobbin 27 12 21 45 DOS 0.75 1H 0.11 bobbin 33 12 21 46 SAI 2.64 TEH 0.95 Plus Point 85 ID 12 21 46 DOS

=

0.71 1H 0.28 bobbin 34

=

12 21 55 DOS 0.7 3H 0.11 bobbin 26 12 21 55 TWD 24 0.6 7H 40.39 bobbin 26 12 21 55 TWD 17 0.36 7H 57.1 bobbin 26 12 21 56 DOS 1.13 1H -0.09 bobbin 26 12 21 57 SAI 2.03 1H

-0.08 Plus Point 29 ID 12 21 57 SAI 1.66 TEH 1.03 Plus Point 44 ID 12 21 57 SAI 2.67 TEH 1.21 Plus Point 44 ID 12 21 57 SAI 1.46 TEH 1.22 Plus Point 44 ID 12 21 57 SAI 2.96 TEH 1.42 Plus Point 44 ID 12 21 57 SAI 2.14 TEH 1.29 Plus Point 44 ID 12 21 57 SAI 1.38 TEH 1.4 Plus Point 44 ID 12 21 57 SAI 1.56 TEH 1.48 Plus Point 44 ID 12 21 57 SAI 1.46 TEH 1.34 Plus Point 44 ID 12 21, 57 SAI 2.32 TEH 1.21 Plus Point 44 ID 12 21 57 DES 1.84 1H 0

bobbin 27 12 21 58 DOS 0.61 2H

-0.09 bobbin 26 12 21 59 DOS 0.37 1H 0.04 bobbin' 27 12 21 60 SAI 0.73 2H

-0.22 Plus Point 29 ID I 12 21 60 SAI 3.12 TEH 1.49 Plus Point 44 ID 12 21 60 SAI 4.1 TEH 1.49 Plus Point 44 ID 12 21 60 SAI 4.07 TEH 1.04 Plus Point 44 ID 12 21 60 SAI 2.17 TEH 0.8 Plus Point 44 ID 12 21 60 SAI 3.89 TEH 0.98 Plus Point 44 ID 12 21 60 SAI 1.56 TEH 0.72 Plus Point 44 ID 12 21 60 SAI 2.16 TEH 0.8 Plus Point 44 ID 12 21 60 DOS 0.68 1H 0.08 bobbin 26 12 21 60 DIS 0.27 2H

-0.19 bobbin 26 12 21 60 DOS 0.75 4H

-0.19 bobbin 26 12 21 62 SAI 3.28 TEH 0.79 Plus Point 44 ID 12 21 62 SAI 3.87 TEH 0.86 Plus Point 44 ID 12 21 62 SAI 4.41 TEH 0.95 Plus Point 44 ID 12 21 62 SAI 3.33 TEH 0.93 Plus Point 44 ID 12 21 62 SAI 3.77 TEH 0.94 Plus Point 44 ID 12 21 62 SAI 2.16 TEH 1.25 Plus Point 44 ID 12 21 62 SAI 2.77 TEH 1.5 Plus Point 44 ID 12 21 62 SAI 2.54 TEH 1.7 Plus Point 44 ID 12 21

62. DOS 1.17 1H 0.02 bobbin 26 12 21 65 SAI 1.93 2H 0.01 Plus Point 29 ID 12 21 65 SAI 0.69 TEH 1.71 Plus Point.44 ID Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal ID/OD Tube Status Reason for Repair 12 21 65 DIS 1.37 2H

-0.02 bobbin 26 12 21 65 TWD 14 0.27 7H 26.04 bobbin 26 12 21 65 TWD 15 0.3 7H 40.48 bobbin 26 12 21 65 TWD 15 0.29 7H 57.1 bobbin 26 12 21 71 DOS 0.73 3H 0.08 bobbin 23 12 21 72 DOS 1.1 4H 0.1 bobbin 23 12 21 82 DOS 0.6 1H

-0.04 bobbin 25 12 22 22 SAI 6

TEH 0.65 Plus Point 85 ID 12 22 22 DOS 1.06 1H 0.02 bobbin 24.

12 22 35 DOS 0.48 1H 0.24 bobbin 26 12 22 35 TWD 23 0.46 7H 24.98 bobbin 26 12 22 37 DOS 0.47 1 H

-0.06 bobbin 26 12 22 40 DOS

=

0.47 2H

-0.04 bobbin 27

=

12 22 41 DOS 0.74 1H

-0.02 bobbin 27 12 22 42 SAI 1.73 1H 0.09 Plus Point 31 ID 12 22 42 SAI

=

2.32 TEH 1.01 Plus Point 85 ID 12 22 42 DIS 1.19 1H 0.11 bobbin 27 12 22 46 DOS 0.68 1 H 0.06 bobbin 33 12 22 54 SAI 0.19 1H 0.13 Plus Pointl 76 OD Plugged SAI-ID/OD @ 2H 12 22 54 *SAI 0.3 1H 0.14 Plus Point 76 OD Plugged -SAI-ID/OD

@ 2H 12 22 54 SAI 2.44 2H 0.02 Plus Point 29 ID Plugged SAI-ID/OD @ 2H 12 22 54 SAI 0.24 2H 0.23 Plus Point 29 OD Plugged SAI-ID/OD @ 2H 12 22 54 SAI 0.14 6H

-0.07 Plus Point 46 OD Plugged SAI-ID/OD @ 2H 12 22 54 SAI 0.28 7H 0.05 Plus Point 46 OD Plugged SAI-ID/OD @ 2H 12 22 54 SAI 1.19 TEH 1.56 Plus Point 44 ID Plugged SAI-ID/OD 2H 12 22 54 SAI 1.34 TEH 1.57 Plus Point 44 ID Plugged SAI-ID/OD @ 2H 12 22 54 DOS 1.77 1H 0.23 bobbin 27 Plugged SAI-ID/OD @ 2H 12 22 54 DIS 2.38 2H 0.04 bobbin 27 Plugged SAI-IDIOD @ 2H 12 22 55 SAl 1.31 3H 0.05 Plus Point 29 ID 12 22 55 DIS 1.22 3H 0.11 bobbin 27

=

12 22 56 DOS 0.58 1H

-0.15 bobbin 27 12 22 57 SAI 0.19 1H

-0.03 Plus Point 76 OD 12 22 57 DOS 0.58 1H

-0.07 bobbin 26 12 22 57 DOS 0.36 2H

-0.04 bobbin 26 12 22 62 SAI 0.38 2H

-0.03 Plus Point 48 OD 12 22 62 DOS 0.61 2H

-0.15 bobbin 27 12 22 79 SAl 0.14 2H 0.02 Plus Point 76 OD 12 22 79 DOS 0.4 1H 0.04 bobbin 25 12 22 79 DIS 0.67 2H 0

bobbin 25

=

12 22 80 SAI 0.22 1H

-0.21 Plus Point 76 OD 12 22 80 DOS 0.53 1 H

-0.23 bobbin 25 12 22 83 SAI 0.16 1H

-0.04 Plus Point 52 OD 12 22 83 OS 0.61 1H

-0.13 bobbin 25 12 22 84 DOS 1.03 1H

-0.04 bobbin 25

=

Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind

%TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 12 23 7

TWD 19 1.29 2C

-0.22 bobbin 22 12 23 12 SAI 0.46 1H

-0.11 Plus Point 31 OD Plugged SAI-OD, >2v DOS @ 1H 12 23 12 SAI 0.29 1H

-0.01 Plus Point 31 OD Plugged SAI-OD, >2v DOS @- 1H 12 23 12 SAI 0.7 1H 0.07 Plus Point 31 OD Plugged SAI-OD, >2v DOS @ 1H 12 23 12 SAI 0.72 1H 0.07 Plus Point 31 OD Plugged SAI-OD, >2v DOS @ 1H 12 23 12 SAI 1.22 1H 0.1 Plus Point 31 OD Plugged SAI-OD >2v DOS @ IH 12 23 12 SAI 0.19 1H 0.13 Plus Point 31 OD Plugged SAI-OD, >2v DOS @ 1H 12 23 12 SAI 0.31 1H 0.16 Plus Point 31 OD Plugged SAI-OD, >2v DOS @I 1H 12 23 12 DOS 3.64 1H 0.06 bobbin 21 Plugged SAI-OD, >2v DOS @ 1H 12 23 17 SAI 1.29 TEH 1.65 Plus Point 85 ID 12 23 17 DOS 0.74 1H 0.09 bobbin 21 12 23 18 DOS 0.48 1H

-0.02 bobbin 23 12 23 22 DOS 0.34 1H

-0.02 bobbin 23 12 23 25 SAI 1.01 3H

-0.28 Plus Point 31 ID 12 23 25 DIS 0.86 3H

-0.26 bobbin 23 12 23 34 DOS 0.76 2H

-0.22 bobbin 26 12 23 54 SAI 0.45 1H 0.15 Plus Point 29 ID 12 23 58 DOS 0.55 1H

-0.04 bobbin 26 12 23 71 SAI 0.17 2H

-0.08 Plus Point 76 OD 12 23 71 SAI 0.16 2H

-0.07 Plus Point 76 OD 12 23 71 DIS 1.55 2H

-0.04 bobbin 23 12 23 79 SAI 0.39 1H

-0.11 Plus Point 49 ID r

12 23 82 SAI 0.25 1H

-0.06 Plus Point 30 OD Plugged SAI-ID/OD @ 1H 12 23 82 SAI 0.49 1H 0.17 Plus Point 30 ID Plugged SAI-IDIOD @ 1H 12 23 82 SAI 0.26 1H

-0.05 Plus Point 30 OD Plugged SAI-IDJOD @ 1H 12 23 82 DOS 0.26 1H 0.06 bobbin 25 _

Plugged SAI-IDIOD @ 1H 12 24 16 DOS 0.32 1H

-0.02 bobbin 22 12 24 18 DOS 0.4 3H

-0.02 bobbin. 24 12 24 22 PVN 10.97 4C 19.24 bobbin 24 12 24 25 DOS 0.47 3H

-0.07 bobbin 24 12 24 28 DOS.

0.93 1H 0.06 bobbin 26 12 24 30 SAI 1.49 2H 0

Plus Point 93 OD Plugged SAI-OD, >2v DOS @c 2H 12 24 30 DOS I___2.58 2H 0.09 bobbin 33 Plugged SAI-OD, >2v DOS @ 2H 12 24 31 SAI 0.42 1H 0.03 Plus Point 94 OD 12 24 31 DOS 0.47 1H 0.04 bobbin 26 12 24 32 SAI 0.25 1H 0.01 Plus Point 81 OD 12 24 32 DOS 0.43 1H 0

bobbin 26 12 24 38 DIS 0.47 1H 0

bobbin 26 12 24 41 DOS 0.34 1H

-0.02 bobbin 27 12 24 41 DOS 0.76 2H

-0.11 bobbin 27 12 24 44 DOS 0.65 1H 0

bobbin 27 12 24 46 SAI.

0.72 1H 0.06 Plus Point 94 OD Plugged SAI-OD, >2v DOS @? 1H 12 24 46 SAI 0.19 1H 0

Plus Point 94 OD Plugged SAI-OD, >2v DOS @ IH 12 24 46 SAI 0.35 1H

-0.01 Plus Point 94 D

Plugged SAl-OD, >2v DOS @ IH Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind

%TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 12 24 46 SAI 0.26 1H

-0.01 Plus Point 94 OD Plugged SAI-OD, >2v DOS @ 1H 12 24 46 DOS 2.44 1H 0.06 bobbin 33 Plugged SAI-OD, >2v DOS @ 1H 12 24 48 SCI 0.34 1H 0.3 Plus Point 90 OD Plugged SCI4D @ 1H 12 24 48 SAI 0.49 4H

-0.21 Plus Point 93 OD Plugged SCI4D @ 1H 12 24 48 DOS 1.16 4H

-0.21 bobbin 33 Plugged SCI-OD @ 1H 12 24 49 SAI 0.17 2H 0.02 Plus Point 93 OD 12 24 49 DOS

=

0.32 2H 0.02 bobbin 34

=

12 24 51 DOS 0.28 1H 0.08 bobbin 27 12 24 55 SAI 0.42 1H 0.03 Plus Point 75 OD 12 24 55 DOS 0.85 1H 0.08 bobbin 27 12 24 65 SAI 0.31 2H 0.06 Plus Point 76 OD 12 24 65 DOS 0.4 2H 0.02 bobbin 27 12 24 74 SAI 0.2 1H -0.07 Plus Point 50 OD Plugged PVN @ 3H +27.63 to +42.02 12 24 74 PVN 2.2 3H 27.63 Plus Point 105

=

Plugged PVN @ 3H +27.63 to +42.02 12 24 74 DOS 0.56 1H

-0.17 bobbin 23 Plugged PVN @ 3H +27.63 to +42.02 12 24 77 SAI 0.61 1H

-0.12 Plus Point 29 ID 12 24 77 DIS 2.65 1H

-0.29 bobbin 24 12 25 14 PVN 10.87 6H 0.17 bobbin 21

=

12 25 17 SAI 0.69 2H

-0.28 Plus Point 31 ID 12 25 17 DIS 0.52 2H 0.04 bobbin 21 12 25 17 DOS 0.49 3H

-0.23 bobbin 21 12 25 25 SAI 2.39 TEH 1.7 Plus Point 85 ID 12 25 25 DOS 0.82 1H

-0.11 bobbin 23 12 25 25 DOS I___0.63 3H 0.13 bobbin 23 12 25 25 DOS 0.6 5H 0.09 bobbin 23 12 25 32 SAI 0.71 1H

-0.09 Plus Point 93 OD 12 25 32 DOS 0.81 1H -0.09 bobbin 26

=

12 25 33 DOS 0.33 1H

-0.02 bobbin 26 12 25 37 SAI 0.19 1H 0.06 Plus Point 93 OD 12 25 37 DOS 0.25 1H -0.28 bobbin 26 12 25 50 SAI 2.48 2H

-0.1 Plus Point 29 ID 12 25 50 SAI 1.43 TEH 1.49 Plus Point 44 ID 12 25 50 DIS 1.77 2H

-0.07 bobbin 26 12 25 55 SAI I__

0.47 2H 0.17 Plus Point 29 ID 12 25 55 DIS 0.54 2H

-0.11 bobbin 26 12 25 57 SAI 1.22 1H 0.07 Plus Point 97 OD 12 25 57 SAI 0.2 1H

.0.2 Plus Point 97 OD 12 25 57 SAI 4.17 TEH 1.45 Plus Point 44 ID 12 25 57 SAI

= 5.43 TEH 1.5 Plus Point 44 ID 12 25 57 SAI _

3.62 TEH 1.11 Plus Point 44 ID 12 25 57 SAI 4.56 TEH 1.47 Plus Point 44 ID 12 25 57 SAI 0.73 TEH 1.19 Plus Point 44 ID 12 25 57 DOS 1.53 1H 0.13 bobbin 26 12 25 61 DOS 0.74 1H 0.11 bobbin 26

=

Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 12 25 63 DOS 0.62 2H 0

bobbin 26 12 25 68 DOS 0.35 2H

-0.08 bobbin 26 12 25 69 DOS 0.71 3H 0.11 bobbin 22 12 25 74 SAI 1.22 1H

-0.32 Pius Point 29 ID 12 25 74 DIS 2.54 1H

-0.29 bobbin 39 12 25 77 DOS 1.11 1H 0.06 bobbin 24

=

12 25 78 SAI 0.3 1H

-0.05 Plus Point 76 OD 12 25 78 DOS

=

0.4 1H 0.02 bobbin 25 12 25 79 SAI 0.48 2H

-0.15 Plus Point 76 ID 12 25 81 SAI 0.39 2H

-0.13 Plus Point 76 OD 12 25 81 DOS 0.9 2H

-0.06 bobbin 25

=

12 25 85 SAI 0.36 2H 0.02 Plus Point 77 OD 12 25 85 SAI 0.65 4H

-0.05 Plus Point 30 ID 12 25 85 DOS 1.11 2H

-0.15 bobbin 25 12 25 87 SAI 1.05 4H

-0.07 Plus Point 30 ID 12 25 87 SAI 1.19 TEH 0.64 Plus Point 43 ID 12 25 87 SAI 1.49 TEH 0.67 Plus Point 43 ID 12 25 87 SAI 0.64 TEH 0.72 Plus Point 43 ID 12 25 87 DIS 0.77: 4H

-0:02 bobbin s24 12 26 10 TWD 27 1.88 2C

-0.08 bobbin

21 12 26 16 DOS 0.61 4H I 0

bobbin 21 12 '26 17 SAI 0.22 3H

-0.19 Plus Point 93 OD 12 26 17 DOS 0.76 2H

-0.11 bobbin 21 12 26 17 DOS 0.44 3H

-0.19 bobbin 21

=

12 26 18 DOS 0.32 SH

-0.02 bobbin 21 12 26 22 SAI 1.7 4H

-0.04 Plus Point 31 ID 12 26 22 SAI 2.73 TEH 1.06 Plus Point 73 ID 12 26 22 DIS 1.7 4H 0

bobbin -

19 9 12 26 26 DOS 0.5 IH

-0.04 bobbin 19 12 26 27 DOS 1.36 1 H 0.06 bobbin 19 12 26 32 DOS 0.84 1H 0.02 bobbin 17 12 26 33 DOS 0.24 1 H

-0.09 bobbin 17 12 26 33 DOS 0.38 2H 0

bobbin 17 12 26 39 SAI 0.79 2H 0

Plus Point 31 ID 12 26 39 DIS 0.33 2H

-0.04 bobbin 15 12 26 52 SAI 0.37 2H 0.01 Plus Point 76 OD 12 26 52 DOS 1.8 2H 0.04 bobbin 20 12 26 64 SAI 0.13 2H 0.14 Plus Point 76 OD 12 26 64 DOS 0.6 2H 0.3 bobbin 18 12 26 68 TWD 28 0.67 7H 87.02 bobbin 20 12 26 68 TWD 22 0.41 7H 68.51 bobbin 20 12 26 68 TWD 21 0.4 7H 47.07 bobbin 20 12 26 68 TWD 23 0.46 7H 28.46 bobbin 20

=

12 26 73 SAI 1.87 1H 0.02 Plus Point 29 ID I Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal ID/OD Tube Status Reason for Repair 12 26 73 SAI 0.8 TEH 1.29 Plus Point 53 ID 12 26 73 DIS 1.19 IH 0

bobbin 20 12 26 79 SAI 1.08 IH 0.07 Plus Point 29 ID 12 26 79 DIS 0.88 IH 0.17 bobbin 20 12 26 83 DOS 0.79 1H 0.19 bobbin 33 12 27 10 TWD 4

0.24 2C

-0.21 bobbin 22 12 27 11 TWD 8

0.51 IC 0.24 bobbin 22 12 27 19 SAI 0.22 IH

-0.17 Plus Point 64 OD 12 27 27 DOS 0.32 1H 0.06 bobbin 20 12 27 27 DOS 0.38 3H

-0.06 bobbin 20 12 27 29 SAI 4.16 TEH 0.75 Plus Point 73 ID 12 27 29 DOS

=

0.54 1H 0.04 bobbin 19 12 27 33 DOS 0.5 2H

-0.06 bobbin 18 12 27 44 SAI 0.2 IH 0.31 Plus Point 93 OD 12 27 55 SAI 0.5 1H 0.28 Plus Point 29 ID 12 27 56 SAI 0.82 1H

-0.21 Plus Point 29 ID 12 27 57 DOS 0.88 1H 0

bobbin 19 12 27 63 SAI 1.1 2H

-0.18 Plus Point 29 ID 12' 27 63 SAI 1.06 2H 0.18 Plus Point 29 ID i

12 27 63 SAI 0.82 TEH 1.88 Plus Point 53 ID 12 27 63 DIS 1.35 2H

-0.09 bobbin 19 12 27 64 SAI 0.53 3H

-0.09 Plus Point 29 ID 12 27 64 SAI 3.6 TEH 1.45 Plus Point 53 ID 12 27 64 SAI 2.55 TEH 14A4 Plus Point 53 ID 12 27 64 SAI 1.67 TEH 1.44 Plus Point 53 ID 12 27 64 SAI 2.78 TEH 1.44 Plus Point 53 ID 12 27 64 SAI 2.03 TEH 1.31 Plus Point 53 ID 12 27 64 SAI 2.52 TEH 1.12 Plus Point 53 ID 12 27 64 SAI 2.39 TEH 0.79 Plus Point 53 ID 12 27 64 SAI 2.57 TEH 0.82 Plus Point 53 ID 12 27 64 DIS 1.38 3H

-0.19 bobbin 19 12 27 65 SAI 0.99 2H 0.12 Plus Point 42 ID 12 27 65 SCI 1.24 TEH 1.62 Plus Point 53 ID 12 27 65 DIS 0.36 2H 0.15 bobbin 20 12 27 66 SAI 0.14 2H

-0.14 Plus Point 39 OD 12 27 66 SAI 0.16 2H 0.13 Plus Point 39 OD 12 27 67 SAI

=

1.75 1H -0.18 Plus Point 29 ID 12 27 67 SAI 0.57 4H

-0.11 Plus Point 29 ID '

12 27 67 DIS 2.86 1H

-0.17 bobbin 20 12 27 67 DIS 0.66 4H

-0.28 bobbin 20 12 27 69 SAI 2.37 IH

-0.1 Plus Point 29 ID 12 27 69 SAI 0.77 IH 0.08 Plus Point 29 ID 12 27 69 SAI 2.9 TEH 0.86 Plus Point 53 ID 12 27 69 SAI 1.39 TEH 0.9 Plus Point 53 ID Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1RI2 SG Row Col Ind %TW Volts Loc Inch Probe Cal IDOD1 Tube Status Reason for Repair 12 27 69 DIS l1.19 1H 0.13 bobbin 21 1 1

1 1

12 27 78 DOS T 0.52 1H

-0.11 bobbin 20T 12 27 83 SAI 0.19 2H

-0.27 Plus Point 43 00OD 12 27 83 DOS

=

0.98 3H 0.09 bobbin 34

=

12 28 10 DOS 0.72 1H 0

bobbin 22 12 28 11 TWD 12 0.75 2C

-0.09 bobbin 21.

12 28 19 DOS 0.19 1H

-0.08 bobbin 21 I

12 28 23 DOS 0.45 1H

-0.04 bobbin 19 12 28 24 SAI _

5.66 TEH 0.77 PIus Point 73 ID I 12 28 24 DOS

_ 0.63 1H 0.06 bobbin 19 12 28 27 DOS =

0.67 2H

-0.09 bobbin 19

=

12 28 29 DOS 0.91 1H 0.06 bobbin 20 12 28 29 DOS 0.8 2H

-0.11 bobbin 20 12 28 35 SAI 0.31 2H

-0.15 PIus Point 93 OD 12 28 35 DOS 0.61 2H

-0.15 bobbin 17 12 28 36 SAI 0.22 2H 0.07 Plus Point 69 OD 12 28 36 DIS 1.28 2H

-0.34 bobbin 17 12 28 40 DIS _

0.6 3H

-0.08 bobbin 13 12 1 28 47 SAI _

0.62 3H 0.14 Plus Point 31 ID 12 28 47 SAI 1.27 TEH 1.26 PIus Point 73 ID 12 28 47 DIS 0.54 3H

-0.11 bobbin 33

=

12 28 53 DOS =

0.71 1H 0.02 bobbin 19

=

12 28 55 DOS 1.32 2H 0.02 bobbin 18 12 28 62 DOS 0.45 1H 0

bobbin 18 12 28 63 DOS 0.77 1H

-0.02 bobbin 18 12 28 66 SAI _

0.38 2H 0.02 PIus Point 29 ID 12 28 66 DIS _

0.26 2H

-0.15 bobbin 20 12 28 84 SAI _

0.42 1H

-0.15 Plus Point 76 OD 12 28 84 DOS 0.85 1 H 0.06 bobbin 20 12 28 84 DOS 0.47 3H 0.06 bobbin 20 12 29 11 DOS 0.65 1 H -0.11 bobbin 22 12 29 12 TWD 19 1.27 2C

-0.09 bobbin 21 12 29 17 DOS 0.61 1H 0.06 bobbin 21 12 29 24 SAI _

1.1 3H 0.25 Plus Point 31 ID 12 29 24 SAI 2.99 TEH 1.58 Plus Point 73 ID 12 29 24 DIS

=

0.85 3H 0.24 bobbin 20

=

12 29 25 DOS 0.71 1H 0

bobbin 19 12 29 25 DOS 0.32 2H 0.08 bobbin 19 12 29 26 DOS 0.23 1H

-0.06 bobbin 20 12 29 27 DOS 0.31 2H

-0.07 bobbin 20 12 29 33 DOS 0.7 1H

-0.04 bobbin 18 12 29 38 SAI 1.28 TEH 1.64 Plus Point 73 ID 12 29 38 DOS 0.56 1H 0

bobbin 18

=

12 29 40 SAI 0.22 5H

-0.06 Pius Point 94 OD Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Cot Ind %TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 12 29 40 DOS 0.88 1H 0.04 bobbin 14

12.

29 40 DOS 1.39 5H

-0.06 bobbin 14 12 29 46 DOS 0.43 IH 0.11 bobbin 34 12 29 47 DOS

=

0.87 1H 0.15 bobbin 34 12 29 49 SAI 0.13' 3H

-0.27 Plus Point 63 OD 12 29 49 DIS 0.91 3H

-0.23 bobbin 13 12 29 51 SAI 0.77 2H

-0.05 Plus Point 29 ID 12 29 51 DIS 0.21 2H 0

bobbin 19 12 29 52 DOS 1.06 1H 0.09 bobbin 19 12 29 54 DOS 0.42 IH 0.06 bobbin 19 12 29 61 SAI 0.17 3H

-0.05 Plus Point 76 OD 12 29 61 DOS 0.61 3H 0.27 bobbin 19 12 29 62 DOS 0.23 2H 0.08 bobbin 19 12 29 66 SAI 1.42 1H 0.06 Plus Pointl 29 ID I 12 29 66 SAI 1.17 TEH 1.76 Plus Point 53 ID 12 29 66 SAI _

1.05 TEH 1.8 Plus Point 53 ID 12 29 66 SAI 1.43 TEH 1.76 Plus Point 53 ID 12 29 66 DIS 0.93 1H 0.1 bobbin 21 12 i29 69 SAI 0.14 IH 0.02 Plus Point 41 OD 12 29 72 DOS 0.37 3H 0.11 bobbin 21.

r 12 29 72 DOS 0.5 6H 0.06 bobbin 21 12 29 77 DOS 0.33 2H 0.02 bobbin r20.

12 29 79 DOS 0.32 1H 0.04 bobbin 20 12 30 13 VOL 0.31 iC 0.18 Plus Point 78 OD 12 30 13 TWD 7

0.45 IC 0.26 bobbin 21 12 30 23 SAI 0.18 2H

-0.06 Plus Point 93 OD Plugged SAI-OD @ 2H Wedge 12 30 23 DOS 0.35 2H

-0.06 bobbin 19 Plugged SAI-4D @ 2H Wedge 12 30 30 SAI 0.97 TEH 1.19 Plus Point 73 ID 12 30 30 DOS 1.38 IH

-0.08 bobbin 19 12 30 35 SAI 5.33 TEH 1.18 Plus Point 73 ID 12 30 35 DOS 1.18 1H

-0.02 bobbin 17 12 30 42 DOS 1.07 IH

-0.06 bobbin 14 12 30 53 DOS 0.79 2H

-0.08 bobbin 19 12 30 56 SAI 2.72 1H

-0.12 Plus Pointl 29 ID 12 30 56 SCI 0.94 TEH 1.76 Plus Point 53 ID 12 30 56 DIS 1.98 1H 0.11 bobbin 18 12 30 57 DOS 0.98 2H 0.08 bobbin 18 12 30 62 SAI 0.53 IH

-0.12 Plus Point 29 ID 12 30 62 SAI 0.35 1H 0.07 Plus Pointl 29 ID 12 30 62 SAI 1.26 TEH 0.73 Plus Point 53 ID 12 30 62 SAI 0.92 TEH 0.74 Plus Point 53 ID 12 30 62 SAI 1.59 TEH 0.79 Plus Point 53 ID 12 30 62 SAI 1.52 TEH 0.92 Plus Point 53 ID 12 30 62 DIS 1.02 1H -0.21 bobbin 18 Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 12 30 67 SAI 2.16 2H

-0.25 Plus Point 29 ID 12 30 67 DIS 7.14 2H

-0.19 bobbin 20 12 30 69 DOS 0.67 1H 0.04 bobbin 20 12 30 72 SAI I__

0.18 2H

-0.04 Plus Point 76 OD 12 30 72 DIS 0.61 2H 0.07 bobbin 20 12 31 16 DOS 1.07 2H 0.11 bobbin 21 12 31 31 DOS

=

0.83 1H

-0.06 bobbin 18

=

12 31 34 DOS 0.79 2H

.0.28 bobbin 18 12 31 37 SAI 0.45 3H

-0.09 Plus Point 32 ID 12 31 37 SAI _

3.66 TEH 0.76 Plus Point 73 ID 12 31 37 DIS 0.09 3H

-0.13 bobbin 17 12 31 41 SAI 0.42 3H

-0.06 Plus Point 93

-OD 12 31 41 DOS 0.56 3H

-0.06 bobbin 13 12 31 44 SAI 0.18 4H 0.17 Plus Point 65 OD 12 31 47 SAI _

2.51 2H

-0.06 Plus Point 31 ID 12 31 47 SAI 0.69 TEH 1.55 Plus Point 73 ID 12 31 47 DIS 3.2 2H

-0.06 bobbin 14 12 31 51 SAI 1.24 1H

-0.11 Plus Point 76 OD Plugged SAI-OD, >2v DOS@ IH 12 31 51 SAI 0.19 1H 0.02 Plus Point 76 OD Plugged SAI-OD, >2v DOS @ IH 12 31 51 SAI 0.21 1H

-0.06 Plus Point 76 OD Plugged SAI-OD, >2v DOS @ 1H 12 31 51 DOS 2.04 1H 0

bobbin 19 _

Plugged SAI-OD, >2v DOS a 1H 12 31 52 DOS 0.31 2H 0.06 bobbin 19.

12 31 53 SAl 2.12 2H

-0.21 Plus Point 29 ID 12 31 53 DIS 1.77 2H

-0.17 bobbin 18.

12 31 62 SAI 0.26 1H

-0.23 Plus Point 39 OD 12 31 63 SAl 0.3 1H

-0.2 Plus Point 76 OD 12 31 63 DOS 0.36 2H

-0.08 bobbin 19 12 31 64 SAI 0.19 1H

-0.05 Plus Point 76 OD 12 31 64 SAI 0.4 1H 0.07 Plus Point 76 OD 12 31 64 DOS 0.54 1H 0.11 bobbin 19 12 31 66 SAl 0.97 4H 0.1 Plus Point 29 ID 12 31 66 SAI 1.52 TEH 0.82 Plus Point 53 ID 12 31 66 SAI 0.88 TEH 0.82 Plus Point 53 ID 12 31 66 SAI 3.64 TEH 0.86 Plus Point 53 ID 12 31 66 SAI 1.74 TEH 1.33 Plus Point 53 ID 12 31 66 SAI 1.87 TEH 1.74 Plus Point 53 ID 12 31 66 DIS I 2.85 4H

-0.23 bobbin 21 12 31 68 SAI 0.84 1H 0.09 Plus Point 29 ID 12 31 68 SAl 2.36 TEH 1.77 Plus Point 53 ID 12 31 68 SA1 1.98 TEH 1.2 Plus Point 53 ID 12 31 68 SAI 1.68 TEH 1.38 Plus Point 53 ID 12 31 68 SAI 2.44 TEH 0.85 Plus Point 53 ID 12 31 68 SAI 1.75 TEH 0.85 Plus Point 53 ID 12 31 68 DIS 0.34 1H 0.07 bobbin 20 56

Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 12 31 70 PVN

=

1.25 6C 0

Plus Point 80 _

Plugged PVN @ 6C +0.00 to +50.63 12 31 78 SAI 0.67 5H 0.61 Plus Point 30 ID Plugged PVN @ 6C -0.41 to +1 3.26 12 31 78 PVN 1.4 6C

-0.41 Plus Point 80 Plugged PVN @ 6C -0.41 to +13.26 12 31 79 SAI 0.26 1 H

-0.03 Plus Point 76 OD Plugged SAI4-D @ 1 H Wedge 12 31 79 SAI 0.14 1H

-0.02 Plus Point 76 OD Plugged SAI-CD @ 1H Wedge 12 31 79 DOS 0.28 1H 0.11 bobbin 34 Plugged SAI-OD @ IH Wedge 12 31 80 SAI 0.17 4H

-0,02 Plus Point 41 OD 12 32 18 PVN 0.81 5H 38.46 Plus Point 105 Plugged PVN @ 5H +38.46 to 6H +36.20 12 32 18 PVN 1.65 6H

-0.26 Plus Point 105

=

Plugged PVN @ 5H +38.46 to 6H +36.20 12 32 22 PVN 1.3 6H 0

Plus Point 105 1

Plugged PVN @ 6H -0.00 to +24.72 12 32 29 SAI 0.64 1H 0

Plus Point 93 OD 12 32 29 SAI 0.58 1H 0

Plus Point 93 OD 12 32 29 DOS 1.54 1 H 0.07 bobbin 20 12 32 30 SAI 0.84 2H

-0.22 Plus Point 31 ID 12 32 30 SAI 1.17 TEH 0.84 Plus Point 73 ID I 12 32 30 SAI 1.8 TEH 1.7 Plus Point 73 ID 12 32 30 DIS 1.3 2H

-0.19 bobbin 19 12 32 37 SAI 0.49 3H 0.03 Plus Point 31 ID 12 32 37 SAI i 3.99 TEH 0.82 Plus Point 73 ID 12 32 37 DIS 0.09 3H 0.04 bobbin '

18 12 32 43 DOS 1.27 4H

-0.09 bobbin 14

12.

32 44 SAI 1.05 4H

-0.14 Plus Point 31 ID 12 32 44 SAI 3.36 TEH 1.57 Plus Point 73 ID 12 32 44 DOS 0.9 2H 0.09 bobbin 13 12 32 44 DOS 0.52 3H

-0.02 bobbin 13 12 32 44 DIS 1.58 4H

-0.19 bobbin 13 12 32 44 DOS 0.31 5H

-0.02 bobbin 13 12 32 45 DOS 0.54 3H

-0.15 bobbin 14 12 32 47 SAI 1.47 3H

-0.13 Plus Point 32 ID 12 32 47 SAI 1.62 TEH 0.7 Plus Point 73 ID 12 32 47 DIS 2.68 3H

-0.19 bobbin 13 12 32 47 DOS 0.42 4H

-0.06 bobbin 13 12 32 50 DOS 0.55 1H 0.11 bobbin 19 12 32 50 TWD 25 0.57 7H 33.09 bobbin 19 12 32 50 TWD 21 0.43 7H 57.67 bobbin 19 12 32 50 TWD 29 0.8 7H 83.62 bobbin 19 12 32 54 SAI 0.23 1H

-0.15 Plus Point 76 OD 12 32 54 SAI 0.29 1H

-0.08 Plus Point 76 OD 12 32 54 DOS 0.73 1H

-0.04 bobbin 18.

12 32 59 DOS 1.23 1H

-0.11 bobbin 19 12 32 62 SAI 0.54 1H

-0.02 Plus Point 29 ID 12 32 62 DIS 1.97 1H

-0.19 bobbin 18 12 32 76 PVN 1.31 6C

-4.55 Plus Point 80 Plugged PVN @ 6C -4.55 to +3.65 12 32 76 DOS 0.29 3H

-0.06 bobbin 34 Plugged PVN @ 6C -4.55 to +3.65 Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 12 33 16 DOS 0.66 IC 0.42 bobbin 21

=

12 33 31 DOS 0.84 3H 0.21 bobbin 18 12 33 40 SAI 0.26 1H 0

Plus Point 67 OD 12 33 45 DIS 0.66 4H 0

bobbin 13 12 33 47 TWD 13 0.23 7H 86.68 bobbin 14 12 33 49 DIS 0.37 2H

-0.09 bobbin 13 12 33 49 DIS 0.5 3H

-0.06 bobbin 13

=

12 33 51 DOS 0.7 2H 0.11 bobbin 19 12 33 54 TWD 14 0.24 7H 59.27 bobbin 19

=

12 33 57 SAI 0.9 2H 0.17 Plus Point 29 ID 12 33 57 SAI 1.54 TEH 0.81 Plus Point 53 ID 12 33 57 SAI 3.85 TEH 1.34 Plus Point 53 ID 12 33 57 SAI 2.11 TEH 1.02 Plus Pointl 53 ID 12 33 57 SAI 2.26 TEH 0.9 Plus Point 53 ID 12 33 57 SAI 3.42 TEH 1.01 Plus Point 53 ID 12 33 57 SAI 2.54 TEH 1.01 Plus Point 53 ID 12 33 57 SAI 1.74 TEH 1.57 Plus Point 53 ID 12 33 57 DIS 0.56 2H 0.17 bobbin 18

=

12 33 68 SAI 0.55 2H 0.08 Plus Point 29 ID 12 33 68 DIS 0.3 2H 0.09 bobbin 20

=

12 33 71 DOS 0.79 1H 0.04 bobbin 20 12 33 72 SAI 0.75 4H

-0.02 Plus Point 29 ID 12 33 72 SAI 1.88 TEH 1.79 Plus Point 53 ID 12 33 72 SAI 1.33 TEH 0.79 Plus Point 53 ID 12 33 72 SAI 1.13 TEH 0.69 Plus Point 53 ID 12 33 72 SAI 2.56 TEH 1.66 Plus Point 53 ID 12 33 72 SAI 2.67 TEH 0.71 Plus Point 53 ID 12 33 72 SAI 1.37 TEH 1.75 Plus Point 53 ID 12 33 72 SAI 1.14 TEH 1.05 Plus Point 53 ED _

12 33 72 SAI 1.04 TEH 0.9 Plus Point 53 ID 12 33 72 SAI 1.23 TEH 0.75 Plus Point 53 ID 12 33 72 DIS 0.91 2H

-0.19 bobbin 21

=

12 33 72 DIS 1.39 4H 0.04 bobbin 21

=

12 34 17 VOL 0.24 IC

-0.19 Plus Point 78 OD 12 34 17 TWD 8

0.47 IC

-0.09 bobbin 21 12 34 19 VOL 0.16 IC

-0.19 Plus Point 78 OD 12 34 19 TWD 5

0.32 iC

-0.19 bobbin 33 12 34 36 SAI 0.73 3H

-0.08 Plus Point 31 ID 12 34 36 SAI 2.65 TEH 0.64 Plus Point 73 ID 12 34 36 DIS 0.18 3H

-0.09 bobbin 17 12 34 39 DOS 0.54 IH 0.11 bobbin 13

=

12 34 42 SAI 0.43 2H 0.1 Plus Point 31 ID 12 34 45 SAI 0.36 IH

-0.08 Plus Point 67 OD 12 34 45 DOS 0.16 1H -0.02 bobbin 14.

Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind

%TW Volts Loc Inch Probe Cal ID/OD Tube Status Reason for Repair 12 34 47 SAI 0.93 2H 0.03 Plus Point 31 ID 12 34 47 SAI

=

1.2 TEH 1.01 Plus Point 73 ID 12 34 47 DIS 0.63 2H 0.02 bobbin 13 12 34 49 SAl 0.41 1H 0.26 Pius Point 94 OD Plugged SAlD 2H, Failed CA Burst 12 34 49 SAI 4.32 2H

-0.17 Plus Point 31 ID Plugged SAl-ID @ 2H, Failed OA Burst 12 34 49 SAI

=

1.05 TEH 1.47 Plus Point 73 ID Plugged SA-ID 2H, Failed OA Burst 12 34 49 DIS 4.94 2H

-0.21 bobbin 14 _

Plugged SAl-ID @ 2H, Failed OA Burst 12 34 51 SAI.

0.43 6H 0.06 Plus Point 29 ID 12 34 51 TWO 22 0.43 7H 115.3 bobbin 18 12 34 51 TWD 37 1.54 7H 88.87 bobbin 18 12 34 53 SAI 2.04 2H 0

Plus Point 29 ID 12 34 53 SAI 0.57 2H

-0.04 Plus Point 29 ID 12 34 53 SAl 0.9 TEH 1.09 Plus Point 53 ID 12 34 53 SAI

=

0.67 TEH 1.24 Plus Point 53 ID 12 34 53 SAl 0.88 TEH 1.39 Plus Point 53 ID 12 34 53 SAI 0.83 TEH 1.54 Plus Point 53 ID 12 34 53 DIS 1.86 2H 0.04 bobbin 19 12 34 54 DOS

=

0.67 3H

-0.06 bobbin 18

=

12 34 55 SAI 2.13; 1H

'0.2 Plus Point 29 ID 12 34 55 DIS 2.1 1 IH

-0.13 bobbin 19 12 34 57 SAI 3.07 2H

-0.15 Plus Point 29 ID Plugged SAl-ID @ 2H, Low OA Burst-Preventive 12 34 57 SAI 3.51 2H

-0.14 Plus Point 29 ID Plugged SAl-ID @ 2H, Low OA Burst-Preventive 12 34 57 SAI 0.22 4H

-0.2 Plus Point 36 OD Plugged SAl-ID @ 2H, Low OA Burst-Preventive 12 34 57 SAI 0.47 TEH 1.78 Plus Point 55 ID Plugged SAl-ID @ 2H, Low OA Burst-Preventive 12 34 57 DIS 5.68 2H

-0.06 bobbin 18 Plugged SAN-ID a) 2H, Low OA Burst-Preventive 12 34 58 SAI _

1.49 2H

-0.07 Plus Point 29 ID 12 34 58 DIS 1.7 2H

-0.02 bobbin 19

=

12 34 59 SAI 0.64 2H 0.01 Plus Point 29 ID 12 34 59 SAI 0.83 TEH 1.51 Plus Point 53 ID 12 34 59 SAI 1.03 TEH 1.52 Plus Point 53 ID 12 34 59 DIS 0.35 2H 0.06 bobbin 19

=

12 34 61 SAI 0.23 1H 0

Plus Point 76 OD 12 34 61 DOS 0.52 1H 0

bobbin 18 12 34 65 SAI 0.43 2H

-0.01 Plus Point 29 ID 12 34 65 SAI 0.97 TEH 0.99 Plus Point 53 ID 12 34 65 SAI 0.99 TEH 0.68 Plus Point 53 ID 12 34 66 TWD 16 0.29 7H 88.87 bobbin 33 12 34 68 DOS 0.38 1H 0.02 bobbin 21 12 34 71 DOS 1.12 1H 0.23 bobbin 21 12 34 74 FSI

=

3.02 7H 110.9 bobbin 21

=

12 35 17 DOS 0.71 1C

-0.26 bobbin 22 12 35 18 DOS 0.76 IC 0.38 bobbin 21 12 35 19 VOL 0.34 IC

-0.24 Plus Point 78 OD 12 35 19 TWD 30 2.16 IC -0.24 bobbin 20

> l' I

Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 12 35 19 TWD 28 2.03 2C

-0.06 bobbin 20 12 35 27 DOS 0.34 1H -0.09 bobbin 20 12 35 27 DOS 0.16 2H

-0.02 bobbin 20 12 35 27 DOS 0.13 3H

-0.02 bobbin 20 12 35 28 DOS 1.08 1H 0.04 bobbin 20 12 35 30 DOS 0.46 1H -0.06 bobbin 20 12 35 36 DOS

=

0.23 6H

-0.04 bobbin 18 12 35 41 DOS 0.56 2H

-0.15 bobbin 13 3 12 35 41 DIS I 0.39 4H

-0.04 bobbin 13 3 12 35 42 DIS 1.01 2H

-0.19 bobbin 13 12 35 46 DOS 0.79 2H

-0.23 bobbin 13 12 35 49 SAI 1.41 2H

-0.03 Plus Point 32 ID 12 35 49 SAI 1.35 TEH 0.88 Plus Point 74 ID 12 35 49 DIS 1.23 2H

-0.06 bobbin 13 12 35 52 SAI 0.84 3H

-0.04 Plus Point 29 ID 12 35 55 SAI 0.18 1H -0.04 PIus Point 96 OD 12 35 55 SAI 0.63 1H -0.04 PIus Point 96 ODO 12 35 55 SAI 0.22 1H -0.03 PIus Point 96 OD 12 35 55 SAI 0.29 1H.0.03 PIus Point 96 OD S.

12 35 55 DOS 1.44 1H 0.06 bobbin 18 12 35 56 SAI 0.5 2H 0.08 PIus Point 29 ID 12 35 56 SAI 1.74 TEH 0.81 Plus Point 53 ID 12 35 56 SAI 1.8 TEH 0.68 Plus Point 53 ID 12 35 56 SAI 1.23 TEH 0.89 Plus Point 53 ID 12 35 56 SAI 2.16 TEH 0.69 Plus Point 53 ID 12 35 56 DIS 1.01 2H

-0.13 bobbin 19 12 35 60 SAI 1.49 1H -0.07 Plus Point 76 OD 12 35 60 DOS 1.85 1H 0

bobbin 19 12 35 68 DOS 0.73 1H 0.11 bobbin 20 =

12 35 70 SAI I 0.99 2H

-0.03 Plus Point 29 ID 12 35 70 DIS 0.51 2H 0.04 bobbin 21 =

12 36 24 DOS 0.6 3H

-0.02 bobbin 19 12 36 33 DOS 0.55 2H

-0.02 bobbin 17 12 36 49 DOS 0.77 2H

-0.08 bobbin 14 12 36 53 SAI 0.27 1H 0.33 PIus Point 36 OD Plugged SAI-ID/SAI-OD/SCI-OD @ 3H 12 36 53 SAI 0.8 3H

-0.07 PIus Point 29 ID Plugged SAI-ID/SAI-ODISCI-OD @ 3H 12 36 53 SCI 0.22 3H 0

PIus Point 29 OD Plugged SAI-ID/SAI-OD/SCI-OD @ 3H 12 36 53 SAI 1.03 TEH 1.11 PIus Point 53 ID Plugged SAI-ID/SAI-ODISCI-OD @ 3H 12 36 53 SAI 1.84 TEH 0.98 PIus Point 53 ID Plugged SAI-ID/SAI-OD/SCI-OD @ 3H 12 36 53 SAI 3.27 TEH 0.98 PIus Point 53 ID Plugged SAI-ID/SAI-ODISCI-OD @ 3H 12 36 53 SAI 1.91 TEH 0.98 PIus Point 53 ID Plugged SAI-ID/SAI-OD/SCI-OD @ 3H 12 36 53 SAI 2.76 TEH 0.98 PIus Point 53 ID Plugged SAI-ID/SAI-ODISCI-OD @ 3H 12 36 53 SAI 2.52 TEH 1.07 PIus Point 53 ID Plugged SAI-ID/SAI-OD/SCI-OD @ 3H 12 36 53 SAI 2.46 TEH 1.61 PIus Point 53 ID Plugged SAI-ID/SAI-OD/SCI-OD @ 3H Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind

%TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 12 36 53 SAI 1.13 TEH 1.58 Plus Point 53 ID Plugged SAI-ID/SAI-OD/SCI-OD 0 3H 12 36 53 DIS 1.64 3H

-0.27 bobbin 19 Plugged SAI-ID/SAI-ODISCI-OD @ 3H 12 36 58 TWD 15 0.26 7H 63.39 bobbin 19 12 36 59 DOS 0.65 1H 0.08 bobbin 19 12 36 60 SAI 1.08 4H

-0.13 Plus Point 29 ID 12 36 60 DIS 1.38 4H -0.08 bobbin 18 12 36 63 TIWD 32 0.98 7H 94.75 bobbin 18 12 36 63 TTWD 20 0.36 7H 64.1 bobbin 18

=

12 36 68 TWD 19 0.38 7H 35.32 bobbin 21 12 36 68 TWD 12 0.21 7H 62.86 bobbin 21 12 37 19 TWD 20 1.38 IC 0.24 bobbin 20 12 37 20 VOL 0.46 IC 0.08 Plus Point 78 OD 12 37 20 TWD 12 0.75 IC 0.09 bobbin 20 12 37 23 SAI 3.89 3H

-0.07 Plus Point 42 OD Plugged SAI-OD, >2v DOS @ 3H 12 37 23 DOS 4.08 3H -0.07 bobbin 20

=

Plugged SAI-OD, >2v DOS @ 3H 12 37 33 DOS 1.03 2H 0.02 bobbin 18 12 37 35 DOS 1.01 2H 0

bobbin 18 12 37 45 DIS 0.89 5H

-0.15 bobbin 13

=

12 37 53' SAI 2:08 2H

-0.07 Plus Point 42 ID 2_'_.

12 37 53 SCI 2.12 TEH 0.96 Plus Point 55 ID 12 37 53 SAI 0.96 TEH 1.51 Plus Point 55 ID 12 37 53 SAI 1.02 TEH 1.66 Plus Point 55 ID 12 37 53 SAI 0.98 TEH 1.82 Plus Point 55 ID 12 37 53 DIS 2.37 2H

-0.13 bobbin 18 12 37 69 SAI 0.85 1H

-0.11 Plus Point 29 ID 12 37 69 SAI 1

IH 0.05 Plus Point 29 ID 12 37 69 SAI 1.44 1H 0.25 Plus Point 29 ID 12 37 69 SAI 0.8 3H 0.19 Plus Point 29 ID 12 37 69 SAI 1.2 TEH 0.64 Plus Point 53 ID 12 37 69 SAI 0.78 TEH 1.46 Plus Point 53 ID 12 37 69 DIS 0.94 1H 0.32 bobbin 21 12 37 69 DIS 0.52 1H -0.08 bobbin 21 12 37 69 DIS 0.6 3H

-0.15 bobbin 21 12 37 70 SAl 1.93 1H -0.02 Plus Point 29 ID 12 37 70 SAI 0.65 TEH 1.68 Plus Point 53 ID 12 37 70 DIS 1.93 1H 0.02 bobbin 21 12 37 73 SAI 0.82 3H

-0.01 Plus Point 29 ID 12 37 73 SAl 1.35 TEH 0.93 Plus Point 53 ID 12 37 73 DIS 0.32 3H 0.08 bobbin 21 12 37 74 SAl 1.39 3H 0.02 Plus Point 30 ID 12 37 74 SAI 0.57 TEH 0.68 Plus Point 53 ID 12 37 74 SAI 0.94 TEH 1.64 Plus Point 53 ID 12 37 74 DIS 1.36 3H 0.11 bobbin 20 12 38 22 TWD 33 2.42 2C

-0.09 bobbin 19 I

Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind

%TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 12 38 23 TWD 22 1.53 2C

-0.09 bobbin 19 12 38 24 DOS 0.43 1H -0.09 bobbin 19 12 38 25 TWD 5

0.3 1C -0.22 bobbin 20 12 38 25 TWD 13 0.86 2C

-0.02 bobbin 20 12 38 34 TWD 15 0.27 7H 66.29 bobbin 17 12 38 34 TWD 16 0.29 7H 34.9 bobbin 17 12 38 41 DOS

=

0.44 1H

-0.11 bobbin 14 12 38 49 TWD 33 1.01 7H 129.8 bobbin 14 12 38 51 TWD 21 0.44 7H 98.4 bobbin 19 12 38 51 TWD 16 0.29 7H 128.6 bobbin 19 12 38 52 TWD 22 0.46 7H 67.01 bobbin 19 12 38 53 TWD 29 0.79 7H 129.2 bobbin 19 12 38 60 TWD 24 0.51 7H 66.85 bobbin 18 12 38 60 TWD 17 0.29 7H 35.68 bobbin 18 12 38 64 TWD 23 0.51 7H 98.88 bobbin 19 12 38 64 TWD 26 0.63 7H 129 bobbin 19 12 38 66 SAI 0.94 1H 0.12 Plus Point 29 ID 12 38 66 DIS 0.49 1H 0.21 bobbin 20 12 38 66 DOS 0.36 3H 0.06 bobbin 20 1

12' 38 66 TWD 20 0.36 7H 99.28 bobbin 20 12 38 66 TWD 24 0.48 7H 129.1 bobbin 20 12 38 67 TWD 10 0.17 7H 98.06 bobbin 21 12 38 72 TWD 16 0.26 7H 66.24 bobbin 20 12 38 72 TWD 10 0.15 7H 98.3 bobbin 20 12 38 74 DOS

=

0.72 4H

-0.06 bobbin 21

=

12 39 23 DOS

=

0.68 1H 0.11 bobbin 20

=

12 39 24 DOS

=

1.16 1H 0.15 bobbin 20

=

12 39 25 DOS

=

0.8 1H

-0.04 bobbin 19

=

12 39 27 DOS

=

0.52 1H

-0.17 bobbin 20 12 39 35 SAI

=

0.36 1H 0.04 Plus Point 93 OD Plugged SAI-OD @ 1H Wedge 12 39 35 DOS

=

0.44 1H 0.04 bobbin 33 =___

Plugged SAI-OD @ 1 H Wedge 12 39 49 SAI _

0.22 2H

-0.19 Plus Point 65 OD 12 39 51 TWD 42 2.67 7H 67.93 bobbin 51 Plugged 42%TW AVB Wear 12 39 51 TWD 22 0.42 7H 36.29 bobbin 18 Plugged 42%TW AVB Wear 12 39 51 TWD 24 0.51 7H 101.6 bobbin 18 Plug ed 42%TW AVB Wear 12 39 57 TWD 22 0.48 7H 101.5 bobbin 19 12 39 66 DOS 0.77 3H 0.06 bobbin 21 12 39 66 TWD 12 0.21 7H 101.2 bobbin 21 12 39 69 TWD 22 0.51 7H 132.4 bobbin 21

=

12 39 70 SAI I=_

0.26 1H

-0.11 Plus Point 34 OD 12 39 70 DIS 1.47 1H

-0.06 bobbin 20 12 39 71 TWD 19 0.34 7H 68.07 bobbin 20 12 39 71 TWD 24 0.52 7H 100.8 bobbin 20 12 39 73 DOS 0.4 1H 0.17 bobbin 21 Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During IR12 SG Row Col Ind %TW Volts Loc Inch Probe Cal ID/OD Tube Status Reason for Repair 12 40 28 DOS 0.21 1H -0.15 bobbin 19 12 40 42 TWD 8

0.14 7H 36.05 bobbin 14 12 40 47 DOS 0.5 4C 0.13 bobbin 14 12 40 56 SAI 0.25 2H 0.03 Plus Point 76 OD 12 40 56 DOS 0.55 2H 0.11 bobbin 18

=

12 40 67 DOS 0.39 2H 0.06 bobbin 21 12 40 68 SAI 0.23 2H

-0.2 Plus Point 76 OD 12 40 68 DOS 0.54 2H

-0.09 bobbin 21 12 41 33 TWD 13 0.83 IC 0.08 bobbin 17 12 41 34 DOS 0.71 2H

-0.09 bobbin 18 12 41 35 DOS 0.28 4H

-0.06 bobbin 18 12 41 46 TWD 20 0.39 7H 107.1 bobbin 13 12 41 50 TWD 14 0.23 7H 71.26 bobbin 18 12 41 52 TWD 12 0.2 7H 106.5 bobbin 19 9 12 41 54 SAI 0.11 3H

-0.24 Plus Point 33 OD 12 42 32 SAI 0.26 1H 0.04 Plus Point 93 OD Plugged SAI-OD 1

1 H Wedge 12 42 32 DOS 0.46 IH 0.04 bobbin 17 Plugged SAI-OD 1

H Wedge 12 42 52 PVN 13.71 2C 15.04 bobbin 18

,12 42 53 PVN 10.02 4C 0

bobbin 19 12 42 55 SAI 0.49 1H

-0.03 Plus Point 33 OD 12 42 55 DOS 0.83 IH 0.06 bobbin 18 12 42 67 DIS 0.39 IH 0.04 bobbin 21 12 43 30 DOS 0.11 3H

-0.07 bobbin 20 12 43 32 TWD 10 0.6 IC

-0.09 bobbin 18 12 43 33 TWD 24 1.64 IC

-0.15 bobbin 17 12 43 35 DOS 0.3 2H

-0.06 bobbin 18 12 43 45 PVN 12.12 IC 42.84 bobbin 13 12 43 46 DIS 0.96 3H 0

bobbin 13 12 43 48 DOS 0.55 4H

-0.13 bobbin 13 12 43 49 SAI 1.21 3H

-0.06 Plus Point 31 ID 12 43 49 SAI 2.48 TEH 0.9 Plus Point 73 ID 12 43 49 DIS 1.01 3H

-0.11 bobbin 13 12 43 64 TWD 19 1.29 2C

-0.15 bobbin 19 12 45 42 SAI 0.25 1H -0.04 Plus Point 67 OD 12 45 42 DOS 1.4 IH 0

bobbin 13 12 45 56 DOS 0.51 IH 0.06 bobbin 19 12 45 58 VOL 0.38 IC 0.01 Plus Point 78 OD 12 45 58 TWD 8

0.49 iC 0

bobbin 19 12 46 43 TWD 4

0.22 IC

-0.21 bobbin 14

=

12 46 49 DOS 1.06 1H -0.13 bobbin 14 12 46 49 DOS 1.36 2H

-0.17 bobbin 14 12 46 52 DOS 0.42 1H 0.06 bobbin 19 13 1

3 DOS 0.41 IH 0.02 bobbin 5

13 1

30 DOS 0.23 5H

-0.04 bobbin 5

Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal ID/OD Tube Status Reason for Repair 13 1

49 PLP 0.15 TSH 0.35 Plus Point 73 13 1

50 PLP 0.14 TSH 0.43 Plus Point 37 13 1

50 DOS 0.49 1H 0

bobbin 3

13 1

61 DOS 0.47 1H

-0.02 bobbin 2

13 1

79 DIS 1.76 3H 0.24 bobbin 3

13 2

2 DOS 0.29 2H 0

bobbin 5

13 2

14 SVI 0.44 TSH

-8.4 Plus Point 31 ID 13 2

45 DOS 0.31 1H 0.04 bobbin 4

=

13 2

49 DOS 0.45 2H 0.04 bobbin 6

13 2

54 DOS 0.33 2H

-0.07 bobbin 2

13 2

56 DOS 0.21 2H

-0.02 bobbin 2

13 2

63 DOS 0.35 3H

-0.07 bobbin 2

13 2

66 DOS 0.73 1H 0

bobbin 3

13 2

66 DOS 0.36 SH

-0.02 bobbin 3

13 3

5 DIS 0.73 2H

-0.33 bobbin 5

13 3

64 DOS 0.34 1 H 0.02 bobbin 3

13 3

73 DOS 0.66 1 H

-0.09 bobbin 2

13 3

77 DOS 0.5 1 H 0

bobbin 2

13 3

81 DOS 0.5 5H 0.02 bobbin 2

13 3

85 DOS 1.49 1 H

-0.02 bobbin 6

13 4

4 DOS 0.18 1 H

-0.07 bobbin 5

13 4

9 SAI 0.33 3H

-0.28 Plus Point 77 OD 13 4

9 DOS 1.21 3H

-0.27 bobbin 4

13 4

48 SAI 0.14 4H 0

Plus Point 77 OD 13 4

48 DOS 0.5 4H

-0.04 bobbin 4

13 4

53 SAI 0.23 2H

-0.06 Plus Point 75 OD 13 4

53 DOS 0.61 2H

-0.07 bobbin 2

13 4

77 SAI 0.32 1H 0.01 Plus Point 75 OD 13 4

77 DOS 1.23 1 H 0.04 bobbin 2

13 4

81 SAI I__

0.13 1H 0.08 Plus Point 50 OD Plugged AONDB @ >5v Dent 13 4

83 DOS 0.3 1 H 0.02 bobbin 2

13 5

11 SAI

=

0.16 3H

-0.09 Plus Point 77 OD 13 5

11 DOS

=

1.13 3H

-0.09 bobbin 4

=

13 5

12 SAI

=

0.16 1H

-0.04 Plus Point 77 OD 13 5

12 SAI 0.22 3H 0.02 Plus Point 77 CD 13 5

12 DOS 0.51 1H 0.11 bobbin 5

13 5

12 DOS 1.09 3H

-0.13 bobbin 5

13 5

32 SCI 1.73 7H 4.81 Plus Point 75 ID Plugged SCI-ID In U-bend 13 5

42 DOS 0.27 1H 0

bobbin 4

13 5

73 SCI 0.54 7H 15.81 Plus Point 79 ID Plugged Multiple SC-ID In U-bend 13 5

73 SCI

=

0.6 7H 17.46 Plus Point 79 ID Plugged Multiple SC-ID In U-bend 13 5

73 SCI

=

0.76 7H 19.7 Plus Point 79 ID Plugged Multiple SC-ID In U-bend 13 5

73 DOS

=

0.52 1H 0.04 bobbin 2

=

Plugged Multiple SC-ID In U-bend 13 5

74 DOS 0.61 1H 0

bobbin 3

Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind

%TW Volts Locl Inch Probe Cal ID/OD Tube Status Reason for Repair 13 5

75 SCI

=

0.72 7H 4.22 Plus Point 79 ID Plugged Multiple SCI-ID In U-bend 13 5

75 SCI 0.74 7H 8.8 Plus Point 79 ID Plugged Multiple SCIID In U-bend 13 5

75 SCI 0.79 7H 10.47 Plus Point 79 ID Plugged Multiple SCIID In U-bend 13 5

75 SCI 0.83 7H 10.85 Plus Point 79 ID Plugged Multiple SCI-ID In U-bend 13 5

75 SCI 0.79 7H 11.16 Plus Point 79 ID Plugged Multiple SCIID In U-bend 13 5

75 SCI

=

0.93 7H 11.82 Plus Point 79 ID Plugged Multiple SCI-ID In U-bend 13 5

75 SCI

=

1.29 7H 12.18 Plus Point 79 ID Plugged Multiple SCI-ID In U-bend 13 5

75 SCI

=

1.3 7H 13.16 Plus Point 79 ID Plugged Multiple SC-ID In U-bend 13 5

75 SCI 1.26 7H 14.15 Plus Point 79 ID Plugged Multiple SCI-ID In U-bend 13 5

75 SCI 1.13 7H 16.64 Plus Point 79 ID Plugged Multiple SC-ID In U-bend 13 5

75 SCI 1.23 7H 17.17 Plus Point 79 ID Plugged Multiple SC-ID In U-bend 13 5

75 SCI 1.4 7H 17.91 Plus Point 79 ID Pluged Multiple SC-ID In U-bend 13 5

75 SCI 1.17 7H 18.78 Plus Point 79 ID Plugged Multiple SCI-ID In U-bend 13 5

75 SCI _

1.02 7H 21.91 Plus Point 79 ID Plugged Multiple SCI-ID In U-bend 13 5

77 SCI

=

1.23 7H 25.5 Plus Point 79 ID Plugged Multiple SC-ID In U-bend 13 5

77 SCI

=

0.85 7H 24.93 Plus Point 79 ID Plugged Multiple SC-ID In U-bend 13 5

77 SCI

=

0.76 7H 23.69 Plus Point 79 ID Plugged Multiple SCI-ID In U-bend 13 5

84 SAl

=

0.14 1H

-0.01 Plus Point 50 OD Plugged AONDB @ >5v Dent 13 6

10 SCI 1.3 7H 4.84 Plus Point 70 ID Plugged SCI-ID In U-bend 13 6

25 SCI 1.2 7H 4.34 Plus Point 64 ID Plugged SCI-ID In U-bend 13 6

29 SCI 1.24 7H 4.53 Plus Point 64 ID Plugged SCI-ID In U-bend 13 6

36 SAI 0.22 1H 0

Plus Point 68 OD 13 6

36 DIS 1.13 1H 0.08 bobbin 22 13 6

59 DOS 0.57 1H 0

bobbin 47 13 6

69 DOS 1.04 1H 0

bobbin 45 13 6

76 DOS 0.2 4H 0

bobbin 43 13 6

79 SAI

=

0.31 1H

-0.01 Plus Point 49 OD 13 6

94 SCI

=

0.47 7H 29.74 Plus Point 63 ID Plugged SCt-ID In U-bend 13 7

19 SCI 1.18 7H 4.59 Plus Point 64 ID Plugged SC-ID In U-bend 13 7

24 DOS

=

0.37 2H

-0.08 bobbin 20

=

13 7

30 DOS I___0.45 5H

-0.06 bobbin 50 13 7

48 SAI

=

0.27 1H 0.01 Plus Point 71 OD Plugged SCI-ID In U-bend 13 7

48 SCI 0.77 7H 33.45 Plus Point 67 ID Plugged SCI-ID In U-bend 13 7

48 DOS 0.54 1H 0.08 bobbin 25 Plugged SCI-ID In U-bend 13 7

57 DIS 0.65 2H

-0.04 bobbin 46 13 7

61 SCI 0.48 7H 4.15 Plus Point 99 ID Plugged SC-ID In U-bend 13 7

75 DOS 0.96 2H 0.25 bobbin 42 13 7

83 DOS 0.63 1H 0.15 bobbin 42 13 7

93 DOS

=

0.52 2H 0

bobbin 43 13 7

94 SAI

=

0.36 5H

-0.06 Plus Point 75 OD 13 7

94 DOS 0.67 5H

-0.02 bobbin 42 13 8

8 DOS 0.37 5C 0.02 bobbin 23 13 8

9 DOS 0.27 4C 0.02 bobbin 23 13 8

9 DOS 0.53 6C

-0.11 bobbin 23 Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 13 8

11 DOS 0.69 1 H 0

bobbin 23

=

13 8

11 DOS 0.83 3H 0.11 bobbin 23 13 8

12 DOS 0.43 6H 0

bobbin 21 13 8

13 SAI 0.24 2H

-0.08 Plus Point 77 OD 13 8

13 DOS 0.56 2H

-0.09 bobbin 21

=

13 8

54 DOS 0.28 1H 0.02 bobbin 46 13 8

61 DOS 0.26 1H 0.04 bobbin 47 13 8

76 DOS 1.38 1H

-0.06 bobbin 43

=

13 9

56 SAI 0.17 6H

-0.16 Plus Point 75 OD Plugged SAI-OD, >2v DOS @ 6H 13 9

56 SAI 0.27 6H

-0.12 Plus Point 75 OD Plugged SAI-OD, >2v DOS @ 6H 13 9

56 SAI 0.15 6H

.0.07 Plus Point 75 OD Plugged SAI-OD, >2v DOS @ 6H 13 9

56 SAI 0.38 TEH 1.16 Plus Point 85 ID Plugged SAI-OD, >2v DOS @ 6H 13 9

56 SAI 3.07 TEH 1.16 Plus Point 85 ID Plugged SAI-OD, >2v DOS @ 6H 13 9

56 SAI 1.15 TEH 1.17 Plus Point 85 ID Plugged SAI-OD, >2v DOS @ 6H 13 9

56 SAI 0.69 TEH 1.3 Plus Point 85 ID Plugged SAI-OD, >2v DOS @ 6H 13 9

56 SAI 2.26 TEH 1.1 Plus Point 85 ID Plugged SAI-OD, >2v DOS @ 6H 13 9

56 SAI 0.93 TEH 1.1 Plus Point 85 ID Plugged SAI-OD, >2v DOS @ 6H 13 9

56 SAI 1.21 TEH 1.3 Plus Point 85 ID Plugged SAI-OD, >2v DOS @ 6H 13 9

56 SAI 1.17 TEH 1.24 Plus Point 85 ID Plugged SAI-OD, >2v DOS @ 6H 13 9

56 SAI 1.02 TEH 1.24 Plus Point 85 ID Plugged SAI-OD, >2v DOS @ 6H 13 9

56 SAI 1.96 TEH 1.25 Plus Point 85 ID Plugged SAI-OD, >2v DOS @ 6H 13 9

56 DOS 0.52 1H 0.17 bobbin 46 Plugged SAI-OD, >2v DOS @ 6H 13 9

56 DOS 0.82 2H 0.04 bobbin 46 Plugged SAI-OD, >2v DOS @ 6H 13 9

56 DOS 1.55 3H 0.04 bobbin 46 Plugged SAI-OD, >2v DOS @ 6H 13 9

56 DOS 2.01 6H

-0.02 bobbin 46 Plugged SAI-OD, >2v DOS @ 6H 13 9

56 DOS 0.28 7H 0

bobbin 46 Plugged SAI-OD, >2v DOS @ 6H 13 9

57 SAI 0.86 11H 0.07 Plus Point 76 OD 13 9

57 SAI 0.12 5H 0

Plus Point 76 OD 13 9

57 SAI 0.2 5H

.0.01 Plus Point 76 OD 13 9

57 SAI 0.14 5H

-0.01 Plus Point 76 OD 13 9

57 DOS 1.87 1 H 0.11 bobbin 46 13 9

57 DOS 0.6 3H 0

bobbin 46 13 9

57 DOS 0.23 4H 0

bobbin 46 13 9

57 DOS 0.5 5C

-0.02 bobbin 46 13 9

57 DOS 1.71 5H 0

bobbin 46 13 9

58 SAI 0.55 3H 0

Plus Point 75 OD 13 9

58 SAI 0.27 3H

-0.05 Plus Point 75 OD 13 9

58 SAI 0.38 3H

-0.06 Plus Point 75 OD 13 9

58 DOS 1.08 11H 0.24 bobbin 46 13 9

58 DOS 1.75 3H 0.02 bobbin 46 13 9

59 SAI 0.56 1H 0.01 Plus Point 76 OD Plugged SAI-OD, >2v DOS @ 1H 13 9

59 SAI 0.6 2H 0.06 Plus Point 76 00 P

. SAI-OD, >2v DOS @ 1H 13 9

59 DOS 2.34 1H 0.11 bobbin 46 Pug SAI-OD, >2v DOS @ 1H 13. 9 59 DOS 1.75 2H 0

bobbin 46 Plugged SAI-OD >2v DOS @

AH II I

Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind V.1W Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 13 9

59 DOS 0.91 3H 0.02 bobbin 46 Plugged SAI-OD, >2v DOS @ 1H 13 9

59 DOS 0.42 4H 0.09 bobbin 46 Plugged SAI4-D, >2v DOS @ 1H 13 9

60 SAI 0.7 1H

-0.08 Plus Point 75 OD Plugged SAI4-D, >2v DOS @ IH 13 9

60 DOS 2.2 1H 0.04 bobbin 46 Plugged SAI-OD, >2v DOS @ 1H 13 9

60 DOS 1.17 2H 0.17 bobbin 46 Plugged SAI-D, >2v DOS a 1H 13 9

60 DOS 0.5 3H

-0.02 bobbin 46 Plugged SAI-OD, >2v DOS @ 1 H 13 9

60 DOS 0.49 5C

.0.09 bobbin 46 Plugged SAI-OD, >2v DOS @ 1H 13 9

60 DOS 0.95 5H 0.11 bobbin 46 Plugged SAI-OD, >2v DOS @ 1H 13 9

60 DOS 0.29 6H 0.02 bobbin 46 Plugged SAI-OD, >2v DOS @ 1H 13 9

61 SAI 0.25 1H

-0.04 Plus Point 76 OD 13 9

61 SAI 0.45 1H

-0.04 Plus Point 76 OD 13 9

61 SAI 1.58 TEH 1.89 Plus Point 85 ID 13 9

61 SAI 1.33 TEH 1.89 Plus Point 85 ID 13 9

61 SAI 1.23 TEH 1.2 Plus Point 85 ID 13 9

61 DOS 1.88 1H 0.13 bobbin 46 13 9

61 DOS 0.68 2H 0.11 bobbin 46 13 9

61 DOS 0.43 4H 0.13 bobbin 46 13 9

61 DOS 0.62 6H 0.13 bobbin 46 13 9

62 SAI 1.73 1H

-0.06 Plus Point 75~ sOD l Plugged SAI-OD, >2v DOS @ 1H 13 9

62 DOS 2.88 1H 0.02 bobbin 46 Plugged SAI-OD, >2v DOS @c 1H 13 9

62 DOS 0.5 2H 0.18 bobbin 46 Plugged SAI-OD, >2v DOS @ 1H 13 9

62 DOS 0.34 3H 0.09 bobbin 46 Plugged SAI-OD, >2v DOS @ 1H 13 9

62 DOS 0.71 4H 0.04 bobbin 46 Plugged SAI-OD, >2v DOS a IH 13 9

62 DOS 0.95 5H 0.09 bobbin 46 Plugged SAI-OD, >2v DOS @ IH 13 9

62 DOS 0.35 6H 0.07 bobbin 46

=

Plugged SAI-D, >2v DOS @ 1 H 13 9

63 SAI 0.58 4H 0.03 Plus Point 76 OD 13 9

63 DOS 1.67 1H 0.22 bobbin 46 13 9

63 DOS 0.5 2H 0.15 bobbin 46 13 9

63 DOS 0.61 3H 0.11 bobbin 46 13 9

63 DOS 1.71 4H 0.04 bobbin 46 13 9

64 DOS 1.24 3H 0.02 bobbin 46 13 9

65 DOS 0.96 3H 0.07 bobbin 46 13 9

65 DOS 0.46 4H 0.07 bobbin 46 13 9

66 SAI 0.67 1H

-0.03 Plus Point 75 OD 13 9

66 SAI 0.29 1H 0.02 Plus Point 75 OD 13 9

66 SAI 2.75 TEH 1.61 Plus Point 85 ID 13 9

66 SAI 2.08 TEH 1.61 Plus Point 85 ID 13 9

66 SAI 0.43 TEH 1.61 Plus Point 85 ID 13 9

66 SAI 0.52 TEH 1.61 Plus Point 85 ID 13 9

66 SAI 0.74 TEH 1.6 Plus Point '85 ID 13 9

66 SAI 1.17 TEH 1.6 Plus Point 85 ID 13 9

66 SAI 1.11 TEH 1.62 Plus Point 85 ID 13 9

66 SAI 2.14 TEH 1.62 Plus Point 85 ID 13 9

66 SAI 0.31 TEH 1.61 Plus Point 85 ID Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 13 9

66 DOS 1.72 1H 0.15 bobbin 44 13 9

67 DOS 0.68 1H 0.11 bobbin 44 13 9

67 DOS 0.42 3H 0.11 bobbin 44 13 9

67 DOS 0.85 4H 0.09 bobbin 44 13 9

68 DOS 1

2H 0.13 bobbin 44 13 9

68 DOS 0.41 6H 0.04 bobbin 44 13 9

69 DOS 1.25 3H 0

bobbin 44 13 9

70 SAI 2.49 TEH 1.1 Plus Point 85 ID 13 9

70 SAI 0.79 TEH 1.1 Plus Point 85 ID 13 9

70 SAI 1.52 TEH 1.1 Plus Point 85 ID 13 9

70 SAI 1.51 TEH 1.11 Plus Point 85 ID 13 9

70 SAI 1.07 TEH 1.08 Plus Point 85 ID 13 9

70 SAI 1.33 TEH 1.09 Plus Point 85 ID 13 9

70 SAI 2

TEH 1.09 Plus Point 85 ID 13 9

70 SAI 0.52 TEH 1.09 Plus Point 85 ID 13 9

70 SAI 0.96 TEH 1.09 Plus Point 85 ID 13 9

70 SAI 0.32 TEH 1.03 Plus Point 85 ID 13 9

70 DOS 1.65 3H 0

bobbin 44 13 9

70 DOS 0.53. 4H 0.02 bobbin 44 13 9

70 DOS 0.64.

5C

.0.15 bobbin 44 13 9

70 DOS 1.51 5H

-0.02 bobbin 44 13 9

71 SAI 0.21 1H 0.02 Plus Point 76 OD 13 9

71 DOS 0.62 1H 0.07 bobbin 44 13 10 5

SAI 0.1 2H

-0.1 Plus Point 77 OD Plugged SAI-OD @ 2H Wedge 13 10 5

DOS 0.38 2H

-0.02 bobbin 23 Plugged SAI-OD @ 2H Wedge 13 10 10 DOS 1.42 2H 0

bobbin 23 13 10 20 SAI 0.45 TSH

-2.22 Plus Point 61 ID 13 10 21 DOS 0.34 4H

-0.04 bobbin 21 13 10 35 DIS

=

0.22 4H

-0.04 bobbin 21

=

13 10 47 SAI I=_

0.61 2H 0.08 Plus Point 77 OD 13 10 47 DOS 1.45 2H 0

bobbin 25 13 10 71 SAI

=

0.43 1H 0

Plus Point 75 OD Plugged SAI-OD, >2v DOS @ IH 13 10 71 DOS 2.31 1H 0.13 bobbin 45 Plugged SAI-OD, >2v DOS @ 1H 13 10 71 DOS 1.38 3H

-0.11 bobbin 45 Plugged SAI-OD, >2v DOS @ 1H 13 10 78 DOS 0.61 1H 0.04 bobbin 43 13 11 12 DOS 0.37 1H

-0.02 bobbin 20.

13 11 91 DOS 0.55 1 H 0.02 bobbin 43 13 11 92 DIS

=

1.02 1H

-0.02 bobbin 42 13 12 92 VOL 0.28 1C

-0.04 Plus Point 86 OD 13 12 92 TWD 10 0.61 1C

-0.04 bobbin 43

=

13 13 10 SAI 0.14 1H 0

Plus Point 58 OD 13 13 41 DOS 0.12 5H 0

bobbin 22 13 13 90 DOS 0.35 1H 0.15 bobbin 42 13 13 91 VOL 0.19 IC

-0.07 Plus Point 86 OD Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 13 13 91 TWD 6

0.34 IC 0

bobbin 42 r 13 14 73 DOS 1.04 2H 0.04 bobbin 39

=

13 14 86 DOS 0.59 3H 0

bobbin 41 13 15 4 TWD 10 0.65 IC

-0.07 bobbin 14 13 15 64 1WD 13 0.18 7H 40.63 bobbin 36 13 15 73 DOS 0.84 IH 0.28 bobbin 38 13 16 44 DOS 0.3 2H 0

bobbin 19 13 16 49 SAI 0.45 1H

-0.01 PIus Point 71 OD 13 16 49 DOS 1.03 1H

-0.02 bobbin 19 13 16 81 DOS 0.67 IH 0.08 bobbin 39 13 16 89 DOS 0.77 1H 0.09 bobbin 41

=

13 17 22 DOS 0.43 1H 0

bobbin 17 13 17 23 DOS 0.38 2H

-0.11 bobbin 16 13 18 34 DOS 0.37 2H 0

bobbin 17 13 18 40 DOS 0.73 4H 0

bobbin 17 13 18 51 DOS 1.47 IH 0.17 bobbin 41 13 18 51 DOS 1.09 2H 0.15 bobbin 41 13 18 55 DOS 1.4 2H 0.21 bobbin 41

=

A13 18 68 DOS 0.73 IH 0.24 bobbin 37

=

13 18 71 DOS

=

'1.14 2H 0.26 bobbin 39

=

13 18 73 DOS 1.07 1H 0.22 bobbin 39

=

13 19 19 DOS 0.72 1H 0.02 bobbin 16 13 19 44 DOS 1.07 1 H 0.15 bobbin 18 13 19 69 DOS 0.99 1 H 0.15 bobbin 36 13 19 73 DOS 0.52 1 H 0.11 bobbin 38 13 19 80 SAI 0.32 1 H 0.05 PIus Point 48 OD 13 19 88 TWD 19 1.24 IC 0.09 bobbin 40 13 19 90 SAI 0.61 1H 0

Plus Point 77 OD 13 19 90 DOS 1.7 IH 0.24 bobbin 40 13 20 22 DOS 0.82 1H 0.11 bobbin 16 13 20 33 SAI 0.33 IH 0.01 Plus Point 77 OD 13 20 33 DOS 0.84 1H

-0.04 bobbin 17 13 20 35 DOS 1.13 1H 0.13 bobbin 17 13 20 38 SAI 0.66 2H 0.01 Plus Point 77 OD 13 20 38 DOS 1.26 2H 0.06 bobbin 17 13 20 68 DOS I___0.36 1 H 0.22 bobbin 37 13 20 89 DOS 0.3 2C 0.04 bobbin 41 13 21 25 TWD 10 0.14 7H 38.89 bobbin 16 13 21 34 SAI 0.29 IH

-0.05 PIus Point 70 OD 13 21 36 DOS 0.69 1H 0.13 bobbin 16

=

13 21 50 DOS 0.28 2H 0.02 bobbin 41

=

13 21 65 DOS 0.63 5H 0

bobbin 37

=

13 21 70 DOS 0.6 5H 0.08 bobbin 38 13 22 31 DOS 0.26 4H

-0.02 bobbin 17 Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal IDODl Tube Status Reason for Repair 13 22 41 DOS 0.36 IH 0.02 bobbin 17 13 22 44 DOS 0.28 2H

-0.02 bobbin 19 13 22 55 SAI 0.31 IH 0

Plus Point 75 OD 13 22 81 DOS 0.77 1 H 0.09 bobbin 39 13 22 87 DOS 0.8 1H

-0.02 bobbin 41 13 23 24 DOS 0.75 1 H 0

bobbin 17 13 23 24 DOS 0.37 5H

-0.08 bobbin 17

=

13 23 25 DOS 0.27 6H

-0.08 bobbin 16

=

13 23 26 SAI 0.15 1H

-0.04 Plus Point 77 OD 13 23 26 DOS 0.42 1 H 0

bobbin 17 13 23 26 DOS 0.51 2H

-0.04 bobbin 17 13 23 33 TWD 9 0.13 7H 41.94 bobbin 16 13 23 53 DOS 0.54 2H

-0.07 bobbin 40 13 23 57 TWO 10 0.14 7H 43.09 bobbin 48 13 23 57 TWD 10 0.14 7H 61.2 bobbin 48 13 23 66 FSI 2.47 TSH 34.27 bobbin 36

=

13 23 67 DOS 0.55 IH 0.09 bobbin 36 13 23 68 DOS 1.03 2H 0.26 bobbin 36 13 23 87 DOS 0.32, IC 0.34 bobbin 40 13 24 8

DOS 0.31 1H

-0.04 bobbin 15 13 24 41 SAI 0.52 IH

-0.03 Plus Point 77 OD 13 24 41 DOS 1.35 1H

-0.04 bobbin 17

=

13 24 41 DOS 0.26 4H

-0.07 bobbin 17 13 24 86 DOS 0.5 IH 0.07 bobbin 41 13 25 40 TWD 9 0.12 7H 45.58 bobbin 16 13 25 76 DOS 1.27 1 H 0.28 bobbin 38 13 25 81 SAI 0.26 1H 0

Plus Point 77 OD 13 25 81 DOS 1.78 IH 0.13 bobbin 38 13 25 82 SAI 0.11 1H 0

Plus Point 48 OD 13 25 86 VOL I 0.3 IC 0

Pius Point 86 OD 13 25 86 TWD 7 0.45 IC

-0.08 bobbin 40 13 25 87 SAI 0.32 IH

-0.09 Plus Point 77 OD Plugged SAI-OD, >2v DOS @ I H 13 25 87 SAI 0.57 IH

-0.01 Plus Point 77 OD Plugged SAI-OD, >2v DOS @ IH 13 25 87 DOS 2.32 IH 0.09 bobbin 40 Plugged SAI-OD, >2v DOS a 1H 13 26 41 SAI 0.12 1H 0.09 Plus Point 54 OD 13 26 47 DOS 0.86 IH

-0.02 bobbin 8

13 26 51 DOS 0.27 4H

-0.04 bobbin 20 13 26 54 DOS 0.34 5H 0.06 bobbin 35 13 26 80 SAI 0.33 IH 0.02 Plus Point 75 OD 13 26 80 DOS 1.55 IH 0.06 bobbin 34

=

13 27 32 DOS 1.04 2H 0.17 bobbin 11 13 27 39 DOS 0.5 I H

-0.02 bobbin 9

13 27 39 DOS 0.62 2H

-0.07 bobbin 9

13 27 48 TWD 6 0.1 7H 70.42 bobbin 9

Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal ID/OD Tube Status Reason for Repair 13 27 48 TWD 9

0.14 7H 28.49 bobbin 9

=

13 27 49 SAI 0.16 1H 0

Plus Point 83 OD 13 27 49 DIS 0.62 1H

-0.3 bobbin 8

13 28 45 TWD 6

0.1 7H 73.34 bobbin 9

13 28 45 TWD 7

0.11 7H 50.5 bobbin 9

13 28 48 DOS 0.97 1H 0.09 bobbin 8

13 28 52 TWD 11 0.14 7H 73.41 bobbin 20 13 28 52 TWD 11 0.15 7H 50.79 bobbin 20 13 28 56 TWD 12 0.16 7H 50.32 bobbin 21

=

13 28 56 TWD 11 0.15 7H 73.45 bobbin 21 13 28 63 TWD 10 0.1 7H 49.98 bobbin 23 13 28 81 DOS 0.46 1H 0

bobbin 34 13 29 37 DOS 0.61 1H 0.2 bobbin 10 13 29 48 TWD 9

0.15 7H 29.67 bobbin 9

13 29 52 TWD 11 0.15 7H 52.46 bobbin 20 13 29 72 SAI 0.33 1H 0.04 Plus Point 75 OD 13 29 72 DOS 0.64 1H 0.09 bobbin 30 13 29 73 SAI 0.16 2H 0.02 Plus Point 76 OD Plu ged SAI-4D c 2H Wedge 13 29 73 DOS 0.4 2H 0.02 bobbin 1 30

' Plugged SAI-4D @ 2H Wedge 13 30 23 SAI 0.2 1 H 0

Plus Point 50 OD Plugged SAI-4D 1 H Wedge 13 30 32 DOS 0.83 2H 0.17 bobbin 10 13 30 39 DOS 0.48 1H

-0.08 bobbin 8

13 30 42 DOS 0.3 1H 0.02 bobbin 8

13 30 45 SAI 0.33 TSH

-1.91 Plus Point 30 ID 13 30 49 TWD 11 0.19 7H 99.93 bobbin 9

13 30 49 TWD 9

0.14 7H 53.79 bobbin 9

13 30 58 TWD 27 0.61 7H 29.79 bobbin 21 Plugged 40%TW AVB Wear 13 30 58 TWD 24 0.47 7H 101.6 bobbin 21 Plugged 40%TW AVB Wear 13 30 58 TWD 40 2.51 7H 53.68 bobbin 51

=

Plugged 40%TW AVB Wear 13 30 58 TWD 37 2.08 7H 79.03 bobbin 51 Plugged 40%TW AVB Wear 13 31 36 SAI 0.45 TSH

-2.67 Plus Point 30 ID 13 31 49 TWD 9

0.17 7H 55.05 bobbin 8

13 31 60 SAI 0.24 2H 0.03 Plus Point 76 OD 13 31 60 DOS 0.93 2H 0.09 bobbin 24 13 32 24 SAI 0.15 2H

-0.27 Plus Point 83 OD 13 32 24 SAI 0.33 2H 0.01 Plus Point 83 OD 13 32 24 DOS 0.61 2H 0

bobbin 12 13 32 31 DOS 0.79 1H

-0.11 bobbin 10 13 32 38 TWD 30 0.7 7H 56.33 bobbin 11 13 32 38 TWD 14 0.19 7H 31.47 bobbin 11 13 32 39 DOS 0.36 1H

-0.02 bobbin 8

13 32 40 SAI 0.32 11H

-0.09 Plus Point 75 0D 13 32 40 DOS 0.81 1H

-0.09 bobbin 8

13 32 46 DOS 0.51 1IH

.0.06 bobbin 8

Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col nd %TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 13 32 50 DOS 0.34 1H 0.11 bobbin 19

=

13 32 61 TWD 15 0.19 7H 32.76 bobbin 23 Plugged 42%TW AVB Wear 13 32 61 TWD 28 0.63 7H 56.08 bobbin 23 Plugged 42%TW AVB Wear 13 32 61 TWD 42 2.97 7H 83.45 bobbin 51 Plugged 42%TW AVB Wear 13 32 65 SAI 0.38 4H

-0.06 Plus Point 75 OD 13 32 65 DOS 0.96 4H 0.04 bobbin 23 13 32 72 SAI 0.12 3H 0.01 Plus Point 50 OD Plugged SAI-OD @ 3H Wedge 13 32 72 SAI 0.09 3H 0.02 Plus Point 50 OD Plugged SAI-OD @ 3H Wedge 13 32 72 DOS 0.22 3H 0.07 bobbin 29

=

Plugged SAI-OD @ 3H Wedge 13 33 27 TWD 11 0.14 7H 86.48 bobbin 11 13 33 37 SAI 0.46 TSH -5.52 Plus Point 30 ID 13 33 44 DOS 0.38 1H 0.04 bobbin 9

13 33 56 TWD 35 1.31 7H 33.28 bobbin 21 Plugged 43%TW AVB Wear 13 33 56 TWD 30 0.82 7H 111.7 bobbin 21 Plugged 43%TW AVB Wear 13 33 56 TWD 36 1.57 7H 57.91 bobbin 21 Plugged 43%TW AVB Wear 13 33 56 TWD 43 3.15 7H 86.39 bobbin 51 Plugged 43%1TW AVB Wear 13 33 57 TWD 20 0.33 7H 57.88 bobbin 21

=

13 33 64 TWD 23 0.39 7H 57.51 bobbin 23 13 33 64 TWD 14 0.17

  • 7H 85.8 bobbin 23 13 33 64 TWD 17 0.22 7H 31.94 bobbin 23 13 34 39 TWD 15 0.33 7H 32.88 bobbin 8

13 34 40 DOS 0.53 1H 0

bobbin 8

13 34 48 DOS 0.88 2H

-0.11 bobbin 8

13 34 68 TWD 15 0.22 7H 60.03 bobbin 26 13 34 70 TWD 10 0.12 7H 87.31 bobbin 29 13 34 78 TWD 18 1.22 2C

-0.21 bobbin 33 13 35 29 TWD 10 0.16 7H 60.79 bobbin 10 13 35 33 DOS 1.1 2H 0.2 bobbin 10 13 35 34 TWD 10 0.13 7H 91.79 bobbin 11 13 35 36 DOS 0.96 2H 0.21 bobbin 11 13 35 41 TWD 6

0.11 7H 61.07 bobbin 9

13 35 48 TWD 10 0.16 7H 91.31 bobbin 9

13 35 48 TWD 12 0.2 7H 61.86 bobbin 9

13 35 52 TWD 10 0.13 7H 61.5 bobbin 20 13 35 57 TWD 15 0.22 7H 61.03 bobbin 21 13 35 68 TWD 12 0.15 7H 116.7 bobbin 25 13 36 36 TWD 11 0.19 7H 62.15 bobbin 10 13 36 38 SAI 0.18 1H 0.02 Plus Point 75 OD 13 36 38 DOS 0.29 11H -0.04 bobbin 11 13 36 40 DOS 0.43 11H 0.02 bobbin 8

=

13 36 42 SAI 0.32 11H -0.02 Plus Point 75 OD 13 36 42 DOS 0.52 11H -0.07 bobbin 8

13 36 48 TWD 10 0.19 7H 93.59 bobbin 8

13 36 53 TWD 12 0.16 7H 63.06 bobbin 20

. Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 13 36 53 TWD 11 0.14 7H 93.83 bobbin 20

=

13 36 56 TWD 26 0.56 7H 62.03 bobbin 22 13 36 56 TWD 22 0.4 7H 93.31 bobbin 22 13 36 56 TWD 16 0.24 7H 121.7 bobbin 22 13 36 57 TWD 16 0.25 7H 93.37 bobbin 22 13 36 59 TWD 15 0.2 7H 93.3 bobbin 21 13 36 61 TWD 31 0.86 7H 62 bobbin 23 13 36 61 TWD 35 1.41 7H 93.52 bobbin 23

=

13 36 61 TWD 22 0.35 7H 120.8 bobbin 23 13 36 64 DOS 0.47 2H 0.08 bobbin 24 13 37 25 TWD 10 0.17 7H 63.69 bobbin 12 13 37 25 TWD 11 0.21 7H 96.86 bobbin 12 13 37 34 TWD 19 0.3 7H 97.02 bobbin 11 13 37 37 DOS 0.77 1H 0.17 bobbin 10 13 37 45 TWD 25 0.59 7H 64.53 bobbin 9

=

Plugged 40hTW AVB Wear 13 37 45 TWD 28 0.73 7H 124.1 bobbin 9

=

Plugged 40°hTWAVB Wear 13 37 45 TWD 40 2.64 7H 96.73 bobbin 51 Plugged 40%TWAVB Wear 13 37 50 TWD 37 2.07 7H 64.59 bobbin 51 13 37 51 DOS 0.4 2H 0

^bobbin 20

=

13 37 68 TWD 23 0.41 7H 63.94 bobbin 25 13 37 68 TWD 15 0.2 7H 95.31 bobbin 25.

13 37 69 TWD 10 0.14 7H 64.39 bobbin 30 13 37 69 TWD 29 0.79 7H 95.68 bobbin 30 13 37 70 TWD 12 0.14 7H 64.5 bobbin 29 13 37 70 TWD 22 0.36 7H 95.29 bobbin 29 13 37 75 TWD 13 0.82 2C

-0.34 bobbin 33 13 38 41 DIS _

0.72 3H

-0.06 bobbin 8

13 38 45 TWD 11 0.21 7H 127.5 bobbin 8

=

13 38 45 TWD 16 0.33 7H 98.95 bobbin 8

=

13 38 45 TWD 7

0.13 7H 66.02 bobbin 8

=

13 38 47 DOS 0.79 1H 0.04 bobbin 8

13 39 24 SAI

=

0.17 2H

-0.26 Plus Pointl 75 OD 13 39 24 SAI 0.25 2H 0

Plus Point 75 OD 13 39 24 DOS 0.44 2H 0

bobbin 13 13 39 45 TWD 8

0.12 7H 101.9 bobbin 9

13 39 45 TWD 7 0.1 7H 67.68 bobbin 9

13 39 46 SAI 0.7 TSH

-2.4 Plus Pointl 30 ID 13 39 52 TWD 14 0.21 7H 67.65 bobbin 20 13 39 66 TWD 25 0.46 7H 130.9 bobbin 23 13 39 69 TWD 11 0.14 7H 67.47 bobbin 29

=

13 40 34 TWD 8

0.12 7H 134.5 bobbin 10 13 40 34 TWD 22 0.48 7H 104.5 bobbin I 10 13 40 34 TWD 15 0.27 7H 68.84 bobbin 10 13 40 41 TWD 24 0.63 7H 134.2 bobbin 8

Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 13 40 41 TWD 19 0.46 7H 104.3 bobbin 8

13 40 47 DOS 0.35 2H

-0.06 bobbin 8

=

13 40 50 SAI 0.15 3H

-0.1 Plus Point 75 OD 13 40 50 DOS 0.64 3H 0

bobbin 19 13 40 56 DOS 0.59 1H 0.24 bobbin 22 13 40 63 TWD 16 0.2 7H 134.4 bobbin 23 13 41 26 DOS 0.31 1H

-0.04 bobbin 11 13 41 26 DOS 0.25 2H

-0.02 bobbin 11 13 41 28 TWD 17 1.12 2C

-0.19 bobbin 11 13 41 32 SAI 0.88 1H 0

Plus Point 75 OD 13 41 32 DOS 0.91 IH 0

bobbin 11 13 41 36 DOS 0.37 1H 0.04 bobbin 11 13 41 50 TWD 17 0.25 7H 69.85 bobbin 20 13 41 50 TWD 17 0.27 7H 106.3 bobbin 20 13 41 50 TWD 24 0.49 7H 138 bobbin 20 13 41 52 TWD 11 0.14 7H 106.4 bobbin 20

13.

41 52 TWD 14 0.19 7H 70.16 bobbin 20 13 41 61 TWD 15 0.2 7H 69.9 bobbin 24 r13 41 63 SAl 0.63 2H

-0.02 Plus Point 75 OD 13 41 63 DOS 0.5 2H

-0.09 bobbin 24 13 42 28 TWD 11 0.66 2C

-0.11 bobbin 11 13 42 32 TWD 17 1.14 2C

-0.13 bobbin 10

=

13 42 45 TWD 7

0.14 7H 109.3 bobbin 8

13 42 45 TWD 8

0.16 7H 72.04 bobbin 8

13 42 55 DOS 0.38 1H 0.08 bobbin 22 13 42 66 DOS 0.47 IC

-0.35 bobbin 24 13 43 36 TWD 20 1.38 2C

-0.11 bobbin 11 13 43 37 TWD 13 0.8 2C

-0.09 bobbin 11 13 43 53 TWD 12 0.16 7H 111.5 bobbin 20 13 43 57 TWD 8 0.11 7H 37.41 bobbin 22 13 43 64 TWO 25 1.77 IC

-0.23 bobbin 24 13 45 43 TWD 7 0.41 2C

-0.04 bobbin 9

14 1

71 DIS 0.32 2H 0.28 bobbin 2

14 2

11 DOS 0.83 4H 0.13 bobbin 3

14 2

23 DOS I 0.36 3H 0.02 bobbin 1

14 2

49 DOS 0.36 1 H 0.02 bobbin 2

14 2

74 DOS 0.41 2H

-0.09 bobbin 2

14 2

92 TWD 13 0.85 IC

-0.21 bobbin 23 14 3

23 DOS 0.75 1 H 0.04 bobbin 2

14 3

35 DOS I 0.43 2H

-0.11 bobbin 2

14 3

35 DOS 0.35 4H

-0.09 bobbin 2

14 3

36 SAI 1.35 1H

-0.1 Plus Point 82 OD Plugged SAI-OD, >2v DOS @ 1H 14 3

36 SAI 0.31 1H 0.05 Plus Point 82 OD Plugged SAI-OD, >2v DOS @ 1H 14 3

36 SAI 0.13 IH 0.01 Plus Point 82 OD Plugged SAI-OD, >2v DOS @_

IH Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind

%TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 14 3

36 DOS

=

2.56 1H 0

bobbin 1

Plugged SAI-OD, >2v DOS @ 1H 14 3

42 DOS 0.85 IH 0.11 bobbin I

14 3

43 DOS 0.43 2H

-0.02 bobbin 2

14 3

44 SAI I__

0.45 1H -0.13 Plus Point 80 OD 14 3

44 SAI 0.23 1H

-0.02 Plus Point 80 OD 14 3

44 SAI 0.15 IH 0.02 Plus Point 80 OD 14 3

44 DOS

=

0.95 IH 0.02 bobbin I

14 3

47 SAI

=

0.95 1H

-0.06 Plus Point 81 OD 14 3

47 SAI 0.12 1H 0.08 Plus Point 81 OD 1 14 3

47 DOS 1.32 IH 0

bobbin 2

14 3

73 DOS 0.36 5H

-0.04 bobbin 2

14 3

74 DOS 1.07 IH 0.19 bobbin 1

14 4

3 TWD 10 0.65 IC

-0.21 bobbin 21 14 4

3 TWD 8

0.49 2C

-0.11 bobbin 21 14 4

5 DOS 0.31 2H

-0.04 bobbin 3

=

14 4

6 SAI

=

0.79 TEH 0.8 Plus Point 80 ID 14 4

6 SAI

=

0.65 TEH 1.8 Plus Point 80 ID 14 4

6 DOS 1.22 3H

-0.07 bobbin 4

14

-4 41 DOS 0.61 2H 0.02 bobbin 1

I 14 4

42 DOS 1.22 1H 0.04 bobbin 2

14 5

27 SCI 1.27 7H 25.62 Plus Point 66 ID Plugged Multiple SCI-ID in U-bend 14 5

27 SCI 0.54 7H 26.1 Plus Point 66 ID Plugged Multiple SCI-ID in U-bend 14 5

28 SCI 0.61 7H 5.74 Plus Point 67 ID Plugged Multiple SCI-ID In U-bend 14 5

28 SCI 0.43 7H 6.44 Plus Point 67 ID Plugged Multiple SCI-ID In U-bend 14 5

28 SCI 0.48 7H 10.3 Plus Point 67 ID Plugged Multiple SCI-ID In U-bend 14 5

28 SCI 1.12 7H 12.92 Plus Point 67 ID Plugged Multiple SCI-ID in U-bend 14 5

28 SCI 1

7H 23.52 Plus Point 67 ID Plugged Multiple SCI-ID in U-bend 14 5

28 SCI 1.04 7H 24.84 Plus Point 67 ID Plugged Multiple SCI-ID in U-bend 14 5

34 DOS 1.26 2H 0.11 bobbin 1

=

14 5

39 DOS 0.53 1H

-0.02 bobbin 1

=

14 5

47 DOS 0.62 1H

-0.08 bobbin 1

=

14 5

48 SCI 1.32 7H 4.8 Plus Point 67 ID Plugged SCI-ID In U-bend 14 5

50 SCI 1.56 7H 4.94 Plus Point 67 ID Plugged SCI-ID in U-bend 14 5

51 SCI I 1 7H 4.64 Plus Point 68 ID Plugged SCI-ID In U-bend 14 5

52 SCI 1.08 7H 4.64 Plus Point 69 ID Plugged SCI-ID In U-bend 14 5

53 SCI 1.15 7H 4.85 Plus Point 68 ID Plugged SCI-ID in U-bend 14 5

54 SCI 0.72 7H 4.61 Plus Point 69 ID Plugged SC-ID In U-bend 14 5

55 SCI 0.86 7H 6.69 Plus Point 68 ID Plugged SCD in U-bend 14 5

56 SCI 1.06 7H 5.19 Plus Point 69 ID Plugged SCI-ID in U-bend 14 5

57 SCI 1.17 7H 4.47 Plus Point 68 ID Plugged SCI-ID in U-bend 14 5

58 SCI 0.81 7H 4.62 Plus Point 69 ID Plugged SCI-ID in U-bend 14 5

59 SCI 1.36 7H 4.98 Plus Point 68 ID Plugged SC-ID in U-bend 14 5

60 SCI 0.92 7H 4.56 Plus Point 69 ID Plugged SCI-ID in U-bend 14 5

61 SCI 1.31 7H 5.32 Plus Point 66 ID Plugged SCI-ID in U-bend Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind

%1.lW Volts Loc Inch Probe Cal ID/OD Tube Status Reason for Repair 14 5

63 SCI 0.8 7H 4.72 Plus Point 66 ID Plugged SCI-ID in U-bend 14 5

64 SCI 1.22 7H 8.76 Plus Point 67 ID Plugged Multiple SCI-ID In U-bend 14 5

64 SCI 0.93 7H 9.56 Plus Point 67 ID Plugged Multiple SCI-ID in U-bend 14 5

64 SCI 1.52 7H 10.9 Plus Point 67 ID Plugged Multiple SCI-ID in U-bend 14 5

64 1

SCI 0.83 7H 18.84 Plus Point 67 ID Plugged Multiple SCI-ID in U-bend 14 5

64 SCI

=

0.57 7H 26.38 Plus Point 67 ID Plugged Multiple SCI-ID in U-bend 14 5

65 SCI 2.1 7H 5.08 Plus Point 66 ID Plugged Multiple SC-ID in U-bend 14 5

65 SCI 0.97 7H 8.07 Plus Point 66 ID Plugged Multiple SCI-ID in U-bend 14 5

65 SCI 0.85 7H 8.82 Plus Point 66 ID Plugged Multiple SCI-ID in U-bend 14 5

65 SCI 0.71 7H 12.43 Plus Point 66 ID Plugged Multiple SCI-ID In U-bend 14 5

65 SCI.

1.02 7H 13.3 Plus Point 66 ID Plugged Multiple SCI-ID in U-bend 14 5

65 SCI 0.8 7H 16.85 Plus Point 66 ID Plugged Multiple SCI-ID in U-bend 14 5

65 SCI 1.29 7H 17.2 Plus Pointl 66 ID Plugged Multiple SCI-ID in U-bend 14 5

65 SCI _

1.69 7H 26.37 Plus Point 66 ID Plugged Multiple SCI-ID In U-bend 14 5

66 SCI

=

0.81 7H 4.69 Plus Point 67 ID Plugged Multiple SCI-ID In U-bend 14 5

66 SCI

=

1.06 7H 4.94 Plus Point 67 ID Plugged Multiple SC-ID in U-bend 14' 5

66 SCI 1.09 7H 26.4 Plus Point 67 ID Plugged Multiple SCI-ID in U-bend 14 5

67 SCI 2.82 7H 5.19 Plus Pointl 66 ID Plugged Multiple SC-ID in U-bend

14.

5 67 SCI _I_

2.18 7H 8.88 Plus Point 66 ID Plugged Multiple SC-ID in U-bend 14 5

67 SCI 1.93 7H 9.52 Plus Point 66 ID Plugged Multiple SC-ID in U-bend 14 5

67 SCI 2.06 7H 10.39 Plus Point 66 ID Plugged Multiple SC-ID In U-bend 14 5

67 SCI 1.71 7H 10.71 Plus Point 66 ID Plugged Multiple SCI-ID in U-bend 14 5

67 SCI 2.24 7H 11 Plus Point 66 ID Plugged Multiple SC-ID in U-bend 14 5

67 SCI 0.72 7H 19.3 Plus Point 66 ID Plugged Multiple SCt-ID in U-bend 14 5

67 SCI 3.65 7H 20.01 Plus Point 66 ID Plugged Multiple SCI-ID in U-bend 14 5

67 SCI 3.63 7H 21.16 Plus Point 66 ID Plugged Multiple SCo-ID in U-bend 14 5

67 SCI

=

2.75 7H 21.58 Plus Point.66 ID Plugged Multiple SCI-ID In U-bend 14 5

67 SCI 3.75 7H 22.04 Plus Point 66 ID Plugged Multiple SCI-ID in U-bend 14 5

67 SCI 2.82 7H 23.15 Plus Point 66 ID Plugged Multiple SCI-ID In U-bend 14 5

67 SCI 2.96 7H 23.54 Plus Point 66 ID Plugged Multiple SCI-ID in U-bend 14 5

67 SCI 3

7H 24.37 Plus Point 66 ID Plugged Multiple SCI-ID In U-bend 14 5

67 SWI 1.06 7H 25.35 Plus Point 66 ID Plugged Multiple SCI-ID in U-bend 14 5

67 SCI 3.94 7H 26.34 Plus Point 66 ID Plugged Multiple SCI-ID in U-bend 14 5

67 SCI 1.93 7H 26.65 Plus Point 66 ID Plugged Multiple SCI-ID in U-bend 14 5

68 SCI 1.22 7H 4.82 Plus Point 67 ID Plugged Multiple SC-ID in U-bend 14 5

68 SCI 1.29 7H 21.09 Plus Point 67 ID Plugged Multiple SC-ID In U-bend 14 5

68 SCI 0.96 7H 5.82 Plus Point 67 ID Plugged Multiple SCI-ID in U-bend 14 5

69 SCI 1.52 7H 4.5 Plus Point 66 ID Plugged Multiple SCI-ID in U-bend 14 5

69 SCI 2.71 7H 6.22 Plus Point 66 ID Plugged Multiple SCI-ID in U-bend 14 5

69 SCI 1.65 7H 9.31 Plus Point 66 ID Plugged Multiple SCI-ID in U-bend 14 5

69 SCt 1.63 7H 26.12 Plus Point 66 ID Plugged Multiple SCo-ID In U-bend 14 5

70 SCt 1.65 7H 4.59 Plus Point 67 ID Plugged Multiple SCt-ID in U-bend 14 5

70 SCI 2.16 7H 4.9 Plus Point 67 ID Plugged Multiple SCI-ID in U-bend 14 5

70 SCI 1.82 7H 6.62 Plus Point 67 ID Plugged Multiple SCI-ID in U-bend Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind

%TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 14 5

70 SCI 2.08 7H 7.45 Plus Point 67 ID Plugged Multiple SC-ID In U-bend 14 5

70 SCI 2.28 7H 8.58 Plus Point 67 ID Plugged Multiple SCI-ID in U-bend 14 5

70 SCI 1.29 7H 10.14 Plus Point 67 ID Plugged Multiple SCI-ID In U-bend 14 5

70 SCI 1.8 7H 15.51 Plus Point 67 ID Plugged Multiple SCI-ID In U-bend 14 5

70 SCI 2.3 7H.24.43 Plus Point 67 ID Plugged Multiple SC-ID In U-bend 14 5

70 SCI 2.48 7H 5.35 Plus Point 67 ID Plugged Multiple SC-ID In U-bend 14 5

72 SAI 0.16 2H 0.06 Plus Point 83 OD 14 5

77 DOS 0.38 2H 0.04 bobbin 1

14 5

78 SAI 0.35 3H

-0.12 Plus Point 88 OD 14 5

78 DOS 1.35 3H

-0.19 bobbin 1

14 5

79 SAl 0.19 1H 0.3 Plus Point 74 OD 14 5

80 DOS 0.56 3H

-0.04 bobbin 1

14 6

3 VOL 0.22 2C

-0.24 Plus Point 75 OD 14 6

3 TWD 8

0.51 2C

-0.17 bobbin 24 14 6

10 DOS 0.3 3H

-0.06 bobbin 26 14 6

12 SAI 1.24 2H

-0.13 Plus Point 80 OD Plugged SAI-OD, >2v DOS C@

2H 14 6

12 SAI 0.22 2H 0.01 Plus Point 80 OD Plugged SAI-OD, >2v DOS @ 2H 14 6

12 DOS 2.59 2H

-0.04 bobbin 49 Plugged SAI-OD, >2v DOS @ 2H 14 6

13 SCI 0.71 7H 28.76 Plus Point 63. ID Plugged SCI-ID in U-bend 14 6

17 SCI 1.87 7H 29.52 Plus Point 63 ID Plugged

-SCI-ID In U-bend 14 6

18 SCI 1.89 7H 29.12 Plus Point 62 ID Plugged Multiple SC-ID in U-bend 14 6

18 SCI 1.28 7H 29.84 Plus Point 62 ID Plugged Multiple SCI-ID in U-bend 14 6

22 SCI 0.57 7H 26.38 Plus Point 62 ID Plugged Multiple SCI-ID In U-bend 14 6

22 SCI 1.27 7H 29.73 Plus Point 62 ID Plugged Multiple SCI-ID In U-bend 14 6

24 SCI 0.72 7H 3.84 Plus Point 62 ID Plugged Multiple SCI-ID in U-bend 14 6

24 SCI 1.27 7H 4.26 Plus Point 62 ID Plugged Multiple SC-ID In U-bend 14 6

24 SCI 0.9 7H 5.76 Plus Point 62 ID Plugged Multiple SC-ID in U-bend 14 6

24 SCI 0.89 7H 6.06 Plus Point 62 ID Plugged Multiple SC-ID In U-bend 14 6

24 SCI 0.89 7H 7.48 Plus Point 62 ID Plugged Multiple SC-ID In U-bend 14 6

24 SCI 1.03 7H 7.92 Plus Point 62 ID Plugged Multiple SCI-ID in U-bend 14 6

24 SCI 0.95 7H 8.42 Plus Point 62 ID Plugged Multiple SCI-ID in U-bend 14 6

24 SCI 0.78 7H 8.86 Plus Point 62 ID Plugged Multiple SC-ID in U-bend 14 6

24 SCI 1.14 7H 9.81 Plus Point 62 ID Plugged Multiple SC-ID In U-bend 14 6

24 SCI 0.71 7H 10.1 Plus Point 62 ID Plugged Multiple SC-ID in U-bend 14 6

24 SCI 0.81 7H 11.18 Plus Point 62 ID Plugged Multiple SC-ID in U-bend 14 6

24 SCI 0.98 7H 11.76 Plus Point 62 ID Plugged Multiple SCI-ID in U-bend 14 6

24 SCI 0.88 7H 12.37 Plus Point 62 ID Plugged Multiple SC-ID in U-bend 14 6

24 SCI 1.47 7H 14.15 Plus Point 62 ID Plugged Multiple SCI-ID in U-bend 14 6

24 SCI

=

0.77 7H 16.53 Plus Point 62 ID Plugged Multiple SC-ID in U-bend 14 6

24 SCI 0.97 7H 22.21 Plus Point 62 ID Plugged Multiple SC-ID in U-bend 14 6

24 SCI 1.11 7H 23.11 Plus Point 62 ID Plugged Multiple SCI-ID in U-bend 14 6

24 SCI 1.23 7H 24.12 Plus Point 62 ID Plugged Multiple SC-ID in U-bend 14 6

24 SCI 0.72 7H 26.68 Plus Point 62 ID Plugged Multiple SCI-ID in U-bend 14 6

24 SCI 1.94 7H 29.29 Plus Point 62 ID Plugged Multiple SC-ID in U-bend Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind

/6TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 14 6

26 SCI 0.93 7H 4.02 Plus Point 62 ID Plugged Multiple SCI-ID In U-bend 14 6

26 SCI 0.44 7H 5.85 Plus Point 62 ID Plugged Multiple SCI-ID In U-bend 14 6

26 SCI 1.23 7H 6.69 Plus Point 62 ID Plugged Multiple SCI-ID in U-bend 14 6

26 SC[I 0.92 7H 10.28 Plus Point 62 ID Plugged Multiple SCI-ID In U-bend 14 6

26 SCI

_ 0.73 7H 10.66 Plus Point 62 ID Plugged Multiple SCI-ID In U-bend 14 6

26 SCI 0.49 7H 21.06 Plus Point 62 ID Plugged Multiple SCI-ID In U-bend 14 6

26 SCI 1.59 7H 29.25 Plus Point 62 ID Plugged Multiple SCI-ID In U-bend 14 6

28 SCI 1.05 7H 20.69 Plus Point 62 ID Plugged Multiple SCI-ID In U-bend 14 6

28 SCI 1.14 7H 21.43 Plus Point 62 ID Plugged Multiple SCI-ID in U-bend 14 6

28 SCI 1.27 7H 22.15 Plus Point 62 ID Plugged Multiple SCI-ID In U-bend 14 6

28 SCI 0.97 7H 28.67 Plus Point 62 ID Plugged Multiple SCI-ID in U-bend 14 6

28 SCI 0.77 7H 29.44 Plus Point 62 ID Plugged Multiple SCI-ID in U-bend 14 6

29 SCI 1.11 7H 29.59 Plus Point 63 ID Plugged SCI-ID in U-bend 14 6

30 SCI 1

0.7 7H 26.37 Plus Point 62 ID Plugged Multiple SCI-ID in U-bend 14 6

30 SCI =

0.61 7H 29.78 Plus Point 62 ID Plugged Multiple SCI-ID in U-bend 14 6

33 SCI 0.72 7H 29.42 Plus Point 65 ID Plugged M

SCI-ID In U-bend 14 6

34 SCI 0.45 7H 28.42 Plus Point 64 ID Plugged Multiple SCI-ID in U-bend 14 6

34 SCI 1.17 7H 29.3 Plus Point 64 ID Plugged Multiple SCI-ID in U-bend 14 6

36 SCI 1.68 7H 29.48 Plus Point 64 ID Plugged SC-ID in U-bend 14 6

38 SCI 2.36 7H A.14 Plus Point 64 ID; Plugged Multiple SC-ID in U-bend 14 6

38 SCI 0.98 7H 3.77 Plus Point 64 ID Plugged Multiple SCI-ID In U-bend 14 6

38 SCI 2.31 7H 4.54 Plus Point 64 ID Plugged Multiple SC-ID in U-bend 14 6

38 SCI 1.67 7H 4.95 Plus Point 64 ID Plugged Multiple SCI-ID In U-bend 14 6

38 SCI 1.51 7H 5.25 Plus Point 64 ID Plugged Multiple SCI-ID In U-bend 14 6

38 SCI

=

1.47 7H 6.44 Plus Point 64 ID Plugged Multiple SCI-ID In U-bend 14 6

38 SCI

=

1.16 7H 13.48 Plus Point 64 ID Plugged Multiple SCI-ID In U-bend 14 6

38 SCI

=

0.91 7H 13.78 Plus Point 64 ID Plugged Multiple SCI-ID in U-bend 14 6

38 SCI

=

1.55 7H 14.22 Plus Point 64 ID Plugged Multiple SCI-ID in U-bend 14 6

38 SCI 1.34 7H 28.26 Plus Point 64 ID Plugged Multiple SCI-ID In U-bend 14 6

38 SCI 1.27 7H 28.66 Plus Point 64 ID Plugged Multiple SCI-ID In U-bend 14 6

38 SCI 1.58 7H 29.35 Plus Point 64 ID Plugged Multiple SCI-ID In U-bend 14 6

40 SCI 0.87 7H 29.67 Plus Point 64 ID Plugged Multiple SCI-ID In U-bend 14 6

40 SC[

1.38 7H 4.13 Plus Point 64 ID Plugged Multiple SCI-ID in U-bend 14 6

40 SCI 0.67 7H 4.67 Plus Point 64 ID Plugged Multiple SCI-ID in U-bend 14 6

40 SCI 0.48 7H 5.51 Plus Point 64 ID Plugged Multiple SCI-ID in U-bend 14 6

40 SCI 0.4 7H 20.9 Plus Point 64 ID Plugged Multiple SCI-ID In U-bend 14 6

40 SCI 0.4 7H 19.86 Plus Point 64 ID Plugged Multiple SCI-ID in U-bend 14 6

40 SCI 0.56 7H 16.84 Plus Point 64 ID Plugged Multiple SCI-ID in U-bend 14 6

40 SCI

=

1.28 7H 14.37 Plus Point 64 ID Plugged Multiple SCI-ID in U-bend 14 6

40 SCI 9_ 1.9 7H 13.52 Plus Point 64 ID Plugged Multiple SCI-ID In U-bend 14 6

40 SCI I___0.26 7H 12.02 Plus Point 64 ID Plugged Multiple SCI-ID in U-bend 14 6

40 SCI 0.99 7H 11.4 Plus Point 64 ID Plugged Multiple SCI-ID in U-bend 14 6

40 SCI 0.47 7H 11.11 Plus Point 64 ID Plugged Multiple SC-ID in U-bend 14 6

40 SCI 0.66 7H 10.74 Plus Point 64 ID Plugged Multiple SCI-ID in U-bend Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 14 6

40 SCI 0.46 7H 10.49 Plus Point 64 ID Plugged Multiple SC-ID In U-bend 14 6

40 SCI 1.19 7H 9.64 Plus Point 64 ID Plugged Multiple SCI-ID in U-bend 14 6

40 SCI 1.1 7H 9.02 Plus Point 64 ID Plugged Multiple SCI-ID In U-bend 14 6

40 SCI 0.87 7H 8.25 Plus Point 64 ID Plugged Multiple SCI-ID in U-bend 14 6

40 SCI 1.12 7H 6.51 Plus Point 64 ID Plugged Multi le S-ID In U-bend 14 6

40 SCI 0.49 7H 7.13 Plus Point 64 ID Plugged Multiple SC-ID In U-bend 14 6

40 SCI

=

0.41 7H 7.46 Plus Point 64 ID Plugged Multiple SCI-ID In U-bend 14 6

40 SCI 0.68 7H 7.78 Plus Point 64 ID Plugged Multiple SC-ID In U-bend 14 6

41 SCI 0.35 7H 8.97 Plus Point 65 ID Plugged Multiple SC-ID In U-bend 14 6

41 SCI 0.34 7H 9.45 Plus Point 65 ID Plugged Multiple SC-ID In U-bend 14 6

41 SCI 0.55 7H 9.8 Plus Point 65 ID Plugged Multiple SC-ID In U-bend 14 6

41 SCI 0.6 7H 10.48 Plus Point 65 ID Plugged Multiple SC-ID In U-bend 14 6

41 SCI 0.6 7H 23.06 Plus Point 65 ID Plugged Multiple SC-ID In U-bend 14 6

41 SCI 1.02 7H 28.49 Plus Pointl 65 ID Plugged Multiple SCI-ID In U-bend 14 6

41 SCI 1.28 7H 20.35 Plus Point 65 ID Plugged Multiple SCI-ID In U-bend 14 6

42 SCI 0.33 7H 13.14 Plus Point 64 ID Plugged Multiple SC-ID in U-bend 14 6

42 SCI 1

1.33 7H 29.16 Plus Point 64 ID Plugged Multiple SCI-ID in U-bend 14 6

42 SCI 0.64 7H 24.44 Plus Point 64 ID Plugged Multiple SC-ID In U-bend 14 6

42 SCI 0.46 7H 15.02 Plus Point 64 v ID Plugged Multiple SC-ID in U-bend 14 6

42 SCI 0.6 7H 14.14 Plus Point 64

, ID Plugged Multiple SCI-ID in U-bend 14 6

42 SCI 0.71 7H 11.6 Plus Point 64 ID Plugged Multiple SC-ID in U-bend 14 6

42 SCI.

0.66 7H 10.55 Plus Point 64 ID Plugged Multiple SC-ID In U-bend 14 6

42 SCI 0.55 7H 10.14 Plus Point 64 ID Plugged Multiple SC-ID in U-bend 14 6

42 SCI 0.85 7H 9.84 Plus Point 64 ID Plugged Multiple SC-ID in U-bend 14 6

42 SCI 0.78 7H 8.67 Plus Point 64 ID Plugged Multiple SC-ID in U-bend 14 6

42 SCI 0.57 7H 8.12 Plus Point 64 ID Plugged Multiple SCI-ID in U-bend 14 6

42 SCI 0.75 7H 7.47 Plus Point 64 ID Plugged Multiple SC-ID in U-bend 14 6

42 SCI 0.73 7H 6.94 Plus Point 64 ID Plugged Multiple SC-ID in U-bend 14 6

42 SCI 1.06 7H 4.5 Plus Point 64 ID Plugged Multiple SC-ID in U-bend 14 6

45 SCI 0.87 7H 29.58 Plus Point 58 ID Plugged SCI-ID In U-bend 14 6

46 SCI 1.14 7H 4.23 Plus Point 59 ID Plugged Multiple SCI-ID in U-bend 14 6

46 SCI 1.34 7H 6.82 Plus Point 59 ID Plugged Multiple SCI-ID In U-bend 14 6

46 SCI 0.53 7H 9.61 Plus Point 59 ID Plugged Multiple SC-ID In U-bend 14 6

46 SCI 0.89 7H 9.85 Plus Pointl 59 ID Plugged Multiple SC-ID In U-bend 14 6

46 SCI 0.48 7H 10.33 Plus Point 59 ID Plugged Multiple SC-ID in U-bend 14 6

46 SCI 0.35 7H 10.73 Plus Point 59 ID Plugged Multiple SCI-ID In U-bend 14 6

46 SCI 0.75 7H 11.6 Plus Point 59 ID Plugged Multiple SC-ID In U-bend 14 6

46 SCI 0.59 7H 12.14 Plus Point 59 ID Plugged Multiple SC-ID in U-bend 14 6

46 SCI 1.26 7H 13.19 Plus Pointl 59 ID Plugged Multiple SCI-ID in U-bend 14 6

46 SCI 0.81 7H 13.91 Plus Point 59 ID Plugged Multiple SC-ID in U-bend 14 6

46 SCI 1.23 7H 14.33 Plus Point 59 ID Plugged Multiple SC-ID in U-bend 14 6

46 SCI 1.35 7H 15.17 Plus Point 59 ID Plugged Multiple SCI-ID in U-bend 14 6

46 SCI 1.28 7H 21.15 Plus Point 59 ID Plugged Multiple SC-ID in U-bend 14 6

46 SCI 1.36 7H 21.42 Plus Point 59 ID Plugged Multiple SCI-ID in U-bend Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind

%TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 14 6

46 SCI 1.12 7H 21.75 Plus Point 59 ID Plugged Multiple SC-ID in U-bend 14 6

46 SCI 0.99 7H 22.07 Plus Point 59 ID Plugged Multiple SC-ID in U-bend 14 6

46 SCI 0.98 7H 23.41 Plus Point 59 ID Plugged Multiple SC-ID in U-bend 14 6

46 SCI 0.93 7H 23.79 Plus Point 59 ID Plugged Multiple SC-ID In U-bend 14 6

46 SCI 1.35 7H 25.18 Plus Point 59 ID Plugged Multiple SC-ID in U-bend 14 6

46 SCI 0.75 7H 25.86 Plus Point 59 ID Plugged Multiple SC-ID In U-bend 14 6

46 SCI 0.97 7h 26.42 Plus Point 59 ID Plugged Multiple SCI-ID In U-bend 14 6

46 SCI 1.55 7H 29.25 Plus Point 59 ID Plugged Multiple SC-ID In U-bend 14 1 6 48 SCI I__

1.17 7H 4.86 Plus Point 59 ID Plugged SC-ID in U-bend 14 6

49 SCI 0.96 7H 4.81 Plus Point 58 ID Plugged SC-ID in U-bend 14 6

50 SCI 1.36 7H 5

Plus Point 59 ID Plugged Multiple SCI-ID In U-bend 14 6

50 SCI 0.97 7H 5.68 Pius Point 59 ID Plugged Multiple SC-ID In U-bend 14 6

50 SCI

=

0.37 7H 6.63 Plus Point 59 ID Plugged Multiple SC-ID In U-bend 14 6

51 SCI 1.67 7H 5.01 Plus Point 59 ID Plugged Multiple SC-ID In U-bend 14 6

51 SCI 0.66 7H 29.6 Plus Point 59 ID Plugged Multiple SCI-ID In U-bend 14 6

53 SCI 1.26 7H 5

Plus Point 59 ID Plugged SCI-ID In U-bend 14 6

54 SCI 0.7 7H 4.88 Plus Point 58 ID Plugged Multiple SCI-ID in U-bend 14 6

54 SCI 0.66 7H 27.31 Plus Point 58 ID Plugged Multiple SC-ID in U-bend 14 6

54 SCI 0.52 7H 29.76 Plus Pointl 58 ID Plugged Multiple SC-ID In U-bend 14 6

54 SCI 0.58 7H 30.24 Plus Point 58 ID Plugged Multiple SCI-ID in U-bend 14 6

55 SCI 1.21 7H 4.91 Plus Point 59 ID Plugged Multiple SC-ID in U-bend 14 6

55 SCI 0.77 7H 5.66 Plus Point 59 ID Plugged Multiple SC-ID in U-bend 14 6

55 SCI

=

0.65 7H 15.09 Plus Point 59 ID Plugged Multiple SCI-ID in U-bend 14 1 6 55 SCI

=

1.21 7H 21.58 Plus Pointl 59 ID Plugged Multiple SC-ID in U-bend 14 6

55 SCI

=

0.96 7H 25.21 Plus Point 59 ID Plugged Multiple SC-ID in U-bend 14 6

55 SCI =

0.57 7H 26.05 Plus Point 59 ID Plugged Multiple SC-ID in U-bend 14 6

57 SCI 1.1 7H 4.82 Plus Point 59 ID Plugged SC-ID In U-bend 14 6

58 SCI 1.32 7H 4.72 Plus Point 58 ID Plugged Multiple SC-ID in U-bend 14 6

58 SCI 0.96 7H 5.21 Plus Point 58 ID Plugged Multiple SC-ID In U-bend 14 6

58 SCI 0.4 7H 10.72 Plus Point 58 ID Plugged Multiple SCi-ID In U-bend 14 6

58 SCI 0.54 7H 12.14 Plus Point 58 ID Plugged Multiple SCi-lD in U-bend 14 6

58 SCI 0.44 7H 12.67 Plus Point 58 ID Plugged Multiple SC-ID In U-bend 14 6

58 SCI 0.56 7H 14.32 Plus Point 58 ID Plugged Multiple SCi-D In U-bend 14 6

58 SCI 0.58 7H 15.08 Plus Point 58 ID Plugged Multiple SC-ID in U-bend 14 6

58 SCI 0.64 7H 17.02 Plus Point 58 ID Plugged Multiple SC-ID In U-bend 14 6

58 SCI 0.53 7H 21.96 Plus Point 58 ID Plugged Multiple SCI-ID in U-bend 14 6

58 SCI 0.42 7H 24.28 Plus Point 58 ID Plugged Multiple SCi-ID in U-bend 14 6

58 SCI 0.41 7H 23.01 Plus Point 58 ID Plugged Multiple SC-ID In U-bend 14 1 6 58 SCI 0.58 7H 25.14 Plus Point 58 ID Plugged Multiple SC-ID In U-bend 14 6

58 SCI 0.74 7H 27.51 Plus Point 58 ID Plugged Multiple SC-ID in U-bend 14 6

58 SCI 0.32 7H 18.62 Plus Point 58 ID Plugged Multiple SCI-ID in U-bend 14 6

59 SCI 1

7H 4.71 Plus Point 59 ID Plugged Multiple SCI-ID in U-bend 14 6

59 SCI 0.49 7H 5.88 Plus Point 59 ID Plugged Multiple SCi-D In U-bend 14 6

60 SCI 1.24 7H 4.66 Plus Point 58 ID Pugged Multiple SC-ID in U-bend Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 14 6

60 SCI 0.71 7H 27.6 Plus Point 58 ID Plugged Multiple SC-ID in U-bend 14 6

60 SCI

=

0.19 7H 24.9 Plus Point 58 ID Plugged Multiple SCI-ID in U-bend 14 6

60 SCI

=

0.59 7H 27.9 Plus Point 58 ID Plugged Multiple SCI-ID In U-bend 14 6

60 SCI 0.34 7H 30.11 Plus Point 58 ID Plugged Multiple SCI-ID In U-bend 14 6

62 SCI 1.12 7H 4.86 Plus Point 59 ID Plugged SC-ID In U-bend 14 6

65 SCI 0.96 7H 9.16 Plus Point 58 ID Plugged Multiple SCI-ID In U-bend 14 6

65 SCI 0.89 7H 9.84 Plus Point 58 ID Plugged Multiple SCI-ID In U-bend 14 6

65 SCI 1.39 7H 10.5 Plus Point 58 ID Plugged Multiple SCI-ID In U-bend 14 6

65 SCI 1.85 7H 12.5 Plus Point 58 ID Plugged Multiple SCI-ID in U-bend 14 6

65 SCI 1.68 7H 12.93 Plus Point 58 ID Plugged Multiple SCI-ID in U-bend 14 6

65 SCI

=

2.07 7H 14.3 Plus Point 58 ID Plugged Multiple SCI-ID In U-bend 14 6

65 SCI 2.14 7H 14.68 Plus Point 58 ID Plugged Multiple SC-ID In U-bend 14 6

65 SCI 2.11 7H 15.99 Plus Point 58 ID Plugged Multiple SC-ID in U-bend 14 6

65 SCI 2.22 7H 16.94 Plus Point 58 ID Plugged Multiple SCI-ID In U-bend 14 6

65 SCI 2.09 7H 17.24 Plus Point 58 ID Plugged Multiple SC-ID in U-bend 14 6

65 SCI 2.33 7H 17.52 Plus Point 58 ID Plugged Multiple SCI-ID In U-bend 14 6

65 SCI 1.82 7H 17.92 Plus Point 58 ID Plugged Multiple SCI-ID In U-bend 14 6

65 SCI 2.08 7H 18.9 Plus Point 58 ID Plugged Multiple SC-ID In U-bend 14 6

65 SCI 2.02 1

,7H 19.47 Plus Point 58 ID Plugged Multiple SCI-ID in U-bend 14 6

65 SCI 2.34 7H 20.37 Plus Point 58 ID Plugged Multiple SC-ID In U-bend 14 6

65 SCI

=

2.32 7H 20.86 Plus Point 58 ID Plugged Multiple SCI-ID in U-bend 14 6

65 SCI

=

2.26 7H 21.66 Plus Point 58 ID Plugged Multiple SC-ID in U-bend 14 6

65 SCI

=

1.87 7H 22.43 Plus Point 58 ID Plugged Multiple SCI-ID In U-bend 14 6

65 SCI 1.71 7H 22.92 Plus Point 58 ID Plugged Multiple SC-ID in U-bend 14 6

65 SCI I___2.52 7H 23.27 Plus Point 58 ID Plugged Multiple SCI-ID In U-bend 14 6

65 SCI 2.55 7H 24.78 Plus Point 58 ID Plugged Multiple SCI-ID In U-bend 14 6

65 SCI 2.67 7H 25.48 Plus Point 58 ID Plugged Multiple SC-ID In U-bend 14 6

65 SCI 1.66 7H 27.77 Plus Point 58 ID Plugged Multiple SC-ID In U-bend 14 6

65 SCI 1.02 7H 29.09 Plus Point 58 ID Plugged Multiple SCI-ID In U-bend 14 6

65 SCI 1.77 7H 30.4 Plus Point 58 ID Plugged Multiple SC-ID In U-bend 14 6

65 SCI 1.73 7H 4.44 Plus Point 58 ID Plugged Multiple SC-ID In U-bend 14 6

65 SCI 2.24 7H 4.81 Plus Point 58 ID Plugged Multiple SCI-ID In U-bend 14 6

65 SCI 1.92 7H 5.81 Plus Point 58 ID Plugged Multiple SCI-ID In U-bend 14 6

65 SCI 1.75 7H 7.47 Plus Point 58 ID Plugged Multiple SCI-ID in U-bend 14 6

66 SCI 1.43 7H 4.73 Plus Point 59 ID Plugged Multiple SCI-ID In U-bend 14 6

66 SCI

=

0.36 7H 10.4 Plus Point 59 ID Plugged Multiple SCI-ID in U-bend 14 6

66 SCI 0.48 7H 10.92 Plus Point 59 ID Plugged Multiple SC-ID in U-bend 14 6

66 SCI 0.63 7H 12.92 Plus Point 59 ID Plugged Multiple SCI-ID in U-bend 14 6

66 SCI 0.45 7H 16.01 Plus Point 59 ID Plugged Multiple SC-ID in U-bend 14 6

66 SCI 0.62 7H 18.58 Plus Point 59 ID Plugged Multiple SC-ID in U-bend 14 6

66 SCI 0.48 7H 19.72 Plus Point 59 ID Plugged Multiple SCI-ID in U-bend 14 6

66 SCI 0.47 7H 20.32 Plus Point 59 ID Plugged Multiple SC-ID in U-bend 14 6

66 SCI 0.4 7H 21.16 Plus Point 59 ID Plugged Multiple SC-ID In U-bend 14 6

66 SCI 0.39 7H 22.98 Plus Point 59 ID Plugged Multiple SCI-ID In U-bend

1, l Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1RI2 SG Row Col Ind %TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 14 6

66 SCI 0.38 7H 23.7 Plus Point 59 ID Plugged Multiple SC-ID in U-bend 14 6

66 SCI 0.56 7H 24.51 Plus Point 59 ID Plugged Multiple SCI-ID In U-bend 14 6

66 SCI 0.47 7H 26.06 Plus Point 59 ID Plugged Multiple SC-ID in U-bend 14 6

66 SC' 0.65 7H 26.75 Plus Point 59 ID Plugged Multiple SCI-ID In U-bend 14 6

66 SCI 0.41 7H 27.2 Plus Point 59 ID Plugged Multiple SCI-ID in U-bend 14 6

66 SCI 0.46 7H 28.48 Plus Point 59 ID Plugged Multiple SC-ID in U-bend 14 6

67 SCI 0.53 7H 6.66 Plus Point 60 ID Plugged Multiple SCI-ID In U-bend 14 6

67 SCI 0.47 7H 10.12 Plus Point 60 ID Plugged Multiple SC-ID in U-bend 14 6

67 SCI 0.36 7H 27.55 Plus Point 60 ID Plugged Multiple SCI-ID in U-bend 14 6

67 SCI 0.59 7H 29.11 Plus Point 60 ID Plugged Multiple SC-ID in U-bend 14 6

67 SCI 0.79 7H 31.89 Plus Point 60 ID Plugged Multiple SC-ID In U-bend 14 6

69 SCI 1.07 7H 4.47 Plus Point 77 ID Plugged Multiple SCI-ID In U-bend 14 6

69 SCI 0.77 7H 4.77 Plus Point 77 ID Plugged Multiple SC-ID In U-bend 14 6

69 SCI 0.59 7H 5.09 Plus Point 77 ID Plugged Multiple SCI-ID in U-bend 14 6

69 SCI 0.91 7H 5.5 Plus Point 77 ID Plugged Multiple SC-ID In U-bend 14 6

69 SCI 1.25 7H 30.24 Plus Point 77 ID Plugged Multiple SCI-ID In U-bend 14 6

78 SCI 1.2 7H 4.86 Plus Point 61 ID Plugged Multiple SC-ID In U-bend 14 6

78 SCI I

7H 11.89 Plus Point 61 ID*

Plugged Multiple SC-ID In U-bend 14 6

78 SCI 0.57.; 7H 14.22k Plus Point 61 ID Plugged Multiple SCI-ID in U-bend 14 6

78 SCI 0.98 7H 15.568 Plus Point 61 ID Plugged Multiple SC-ID In U-bend 14 6

79 SCI 1.97 7H 5.86 Plus Point 61 ID Plugged Multiple SC-ID In U-bend 14 6

79 SCI 1.06 7H 7.68 Plus Point 61 ID Plugged Multiple SCI-ID In U-bend 14 6

79 SCI 0.37 7H 8.48 Plus Point 61 ID Plugged Multiple SC-ID In U-bend 14 6

79 SCI 0.45 7H 8.75 Plus Point 61 ID Plugged Multiple SCI-ID In U-bend 14 6

79 SCI 0.23 7H 10.26 Plus Point 61 ID Plugged Multiple SC-ID In U-bend 14 6

79 SCI 1.26 7H 12.72 Plus Point 61 ID Plugged Multiple SCI-ID in U-bend 14 6

79 SCI 0.87 7H 13.13 Plus Point 61 ID Plugged Multiple SC-ID In U-bend 14 6

80 SCI 0.52 7H 4.17 Plus Point 60 ID Plugged Multiple SCI-ID In U-bend 14 6

80 SCI 0.86 7H 4.89 Plus Point 60 ID Plugged Multiple SC-ID in U-bend 14 6

80 SCI 0.46 7H 5.39 Plus Point 60 ID Plugged Muliple SCI-ID In U-bend 14 6

80 SCI 0.52 7H 5.75 Plus Point 60 ID Plugged Multiple SC-ID in U-bend 14 6

80 SCI 1.21 7H 9.41 Plus Point 60 ID Plugged Multiple SC-ID In U-bend 14 6

80 SCI 0.81 7H 9.94 Plus Point 60 ID Plugged Multiple SC-ID In U-bend 14 6

80 SCI 0.93 7H 10.82 Plus Point 60 ID Plugged Multiple SCI-ID in U-bend 14 6

80 SCI 1.04 7H 11.53 Plus Point 60 ID Plugged Multiple SC-ID in U-bend 14 6

80 SCI 0.86 7H.11.94 Plus Point 60 ID Plugged Multiple SCI-ID In U-bend 14 6

80 SCI 1.13 7H 14.2 Plus Point 60 ID Plugged Multiple SC-ID In U-bend 14 6

80 SCI 0.45 7H 14.63 Plus Point 60 ID Plugged Multiple SCI-ID In U-bend 14 6

80 SCI 0.8 7H 28.07 Plus Point 60 ID Plugged Multiple SCI-ID In U-bend 14 6

80 SCI _

0.5 7H 29.76 Plus Point 60 ID Plugged Multiple SC-ID In U-bend 14 6

80 SCI 0.67 7H 30.13 Plus Point 60 ID Plugged Multiple SC-ID In U-bend 14 6

82 SCI 0.77 7H 4.6 Plus Point 60 ID Plugged Multiple SCI-ID in U-bend 14 6

82 SCI 0.63 7H 5.27 Plus Point 60 ID Plugged Multiple SC-ID in U-bend 14 7

26 SCI 0.86 7H 32.22 Plus Point 62 ID Plugged SC-ID in U-bend Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 14 7

28 SCI.

1.27 7H 33.28 Plus Point 62 ID Plugged SCI-ID in U-bend 14 7

45 SCI 0.9 7H 5.25 Plus Point 65 ID Plugged Multiple SCI-ID In U-bend 14 7

45 SCI 0.53 7H 5.58 Plus Point 65 ID Plugged Multiple SC-ID In U-bend 14 7

45 SCI 0.4 7H 6.33 Plus Pointl 65 ID Plugged Multiple SCI-ID In U-bend 14 7

45 SCI 1.05 7H 7.19 Plus Point 65 ID Plugged Multiple SCI-ID in U-bend 14 7

45 SCI

=

0.85 7H 7.73 Plus Point 65 ID Plugged Multiple SCI-ID In U-bend 14 7

45 SCI 1

7H 8.47 Plus Point 65 ID Plugged Multiple SCI-ID in U-bend 14 7

45 SCI 0.82 7H 9.47 Plus Point 65 ID Plugged Multiple SCI-ID in U-bend 14 7

45 SCI 0.95 7H 9.91 Plus Point 65 ID Plugged Multiple SCI-ID In U-bend 14 7

45 SCI 0.97 7H 10.26 Plus Point 65 ID Plugged Multiple SCI-ID in U-bend 14 7

45 SCI 1.09 7H 10.67 Plus Point 65 ID Plugged Multiple SC-ID in U-bend 14 7

45 SCI 0.93 7H 11.37 Plus Point 65 ID Plugged Multiple SCI-ID In U-bend 14 7

45 SCI 0.71 7H 11.78 Plus Point 65 ID Plugged Multiple SCI-ID in U-bend 14 7

45 SCI 1.02 7H 12.42 Plus Pointl 65 ID Plugged Multiple SCI-ID in U-bend 14 7

45 SCI 0.88 7H 13.71 Plus Point 65 ID Plugged Multiple SCI-ID in U-bend 14 7

45 SCI 1.05 7H 14.76 Plus Point 65 ID Plugged Multiple SCi-ID in U-bend 14 7

45 SCI 0.7 7H 15.52 Plus Point 65 ID Plugged Multiple SC-ID In U-bend 14 7

45 SCI 0.44 7H 23.15 Plus Point 65 ID Plugged Multiple SCI-ID in U-bend 14 7

45 SCI 0.37 7H 25 Plus Point 65 ID Plugged Multiple SCI-ID In U-bend 14 7

45 SCI 0.46 7H 25.55 Plus Point 65 ID Plugged Multiple SCI-ID In U-bend 14 7

45 SCI 0.49 7H 26.88 Plus Point 65 ID Plugged Multiple SCI-ID In U-bend 14 7

45 SCI 0.33 7H 27.78 Plus Point 65 ID Plugged Multiple SCI-ID In U-bend 14 7

45 SCI 0.33 7H 31.91 Plus Point 65 ID Plugged Multiple SCI-ID in U-bend 14 7

58 SCI 1.08 7H 4.55 Plus Point 59 ID Plugged Multiple SCI-ID In U-bend 14 7

58 SCI 0.78 7H 4.91 Plus Point 59 ID Plugged Multiple SCI-ID in U-bend 14 7

59 SCI 0.32 7H 23.27 Plus Point 58 ID Plugged Multiple SCI-iD in U-bend 14 7

59 SCI=

0.68 7H 30.84 Plus Point 58 ID Plugged Multiple SCI-ID in U-bend 14 7

59 SCI 0.51 7H 7.5 Plus Pointl 58 ID Plu ged Multiple SCI-ID In U-bend 14 7

59 SCI 0.74 7H 31.65 Plus Point 58 ID Plugged Multiple SCI-ID in U-bend 14 7

61 SCI 0.38 7H 13.62 Plus Point 58 ID Plugged Multiple SCI-ID in U-bend 14 7

61 SCI 1.14 7H 34.17 Plus Point 58 ID Plugged Multiple SCI-ID In U-bend 14 7

61 SCI I 0.89 7H 33.54 Plus Point 58 ID Plugged Multiple SC-ID in U-bend 14 7

61 SCI 0.66 7H 32.79 Plus Point 58 ID Plugged Multiple SC-ID in U-bend 14 7

65 SCI 0.96 7H 6.37 Plus Point 59 ID Plugged Multiple SCI-ID in U-bend 14 7

65 SCI 0.74 7H 32.84 Plus Point 59 ID Plugged Multiple SCI-ID in U-bend 14 7

65 SCI 0.8 7H 33.23 Plus Point 59 ID Plugged Multiple SCI-ID in U-bend 14 7

65 SCI 1.15 7H 33.49 Plus Point 59 ID Plugged Multiple SCI-ID in U-bend 14 7

65 SCI 1.38 7H 34.1 Plus Point 59 ID Plugged Multiple SCI-ID in U-bend 14 7

70 SCI 0.28 7H 13.17 Plus Point 60 ID Plugged Multiple SCt-ID in U-bend 14 7

70 SCI 0.8 7H 13.79 Plus Point 60 ID Plugged Multiple SCI-ID In U-bend 14 7

70 SCI 0.75 7H 14.31 Plus Point 60 ID Plugged Multiple SCI-ID in U-bend 14 7

70 SCI 0.71 7H 15.05 Plus Point 60 ID Plugged Multiple SC-ID In U-bend 14 7

70 SCI 0.56 7H 15.52 Plus Point 60 ID Plugged Multiple SCI-ID in U-bend 14 7

70 SCI 0.43 7H 16.8 Plus Point 60 ID Plugged Multiple SCI-ID in U-bend r

Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe lCal IDIOD Tube Status Reason for Repair 14 7

70 SCI 0.91 7H 18.38 Plus Point 60 ID Plugged Multiple SCI-ID In U-bend 14 7

70 SCI 1.05 7H 23.1 Plus Point 60 ID Plugged Multiple SCI-ID in U-bend 14 7

70 SCI 1.1 7H 28.15 Plus Point 60 ID Plugged Multiple SCI-ID In U-bend 14 7

70 SCI 0.55 7H 21 Plus Point 60 ID Plugged Multiple SCI-ID In U-bend 14 7

70 SCI 0.83 7H 23.92 Plus Point 60 ID Plugged Multiple SCI-ID in U-bend 14 7

70 SCI 0.65 7H 24.66 Plus Point 60 ID Plugged Multiple SCI-ID in U-bend 14 7

70 SCI 0.69 7H 25.62 Plus Point 60 ID Plugged Multiple SC-ID in U-bend 14 7

73 SCI 0.78 7H 4.89 Plus Point 61 ID Plugged Multiple SCI-ID In U-bend 14 7

73 SCI 0.41 7H 5.67 Plus Point 61 ID Plugged Multiple SCI-ID In U-bend 14 7

78 DOS 0.18 1H 0.06 bobbin 38 14 8

31 DOS 0.47 1 H 0.02 bobbin 27 14 8

32 SAI 0.15 3H 0.02 Plus Point 82 OD 14 8

32 DOS 0.36 3H

-0.04 bobbin 28 14 8

33 SCI 1.04 7H 37.08 Plus Point 65 ID Plugged SCI-ID In U-bend 14 8

34 DOS 0.63 1H

-0.04 bobbin 28 14 8

56 SCI 0.59 7H 5.4 Plus Point 58 ID Plugged SCI-ID In U-bend 14 8

59 SCI 0.77 7H 5.06 Plus Pointl 58 ID Plugged SC-ID in U-bend 14 8

59 DOS 0.44 4H 0.04 bobbin 38 Plugged SCI-ID in U-bend 14 8

60 SCI 1 0.79 7H 5.21 Plus Point 58 ID Plugged SC-ID in U-bend 14 9

2 VOL 0.49 2C

-0.23 Plus Point 75 OD 14 9

2 TWO 29 2.08 2C

-0.13 bobbin 47 14 9

5 VOL 0.37 2C 0.14 Plus Point 81 OD 14 9

5 TWD 10 0.6 2C 0.17 bobbin 18 14 9

9 SAI 0.42 3H

-0.13 Plus Point 80 OD 14 9

9 DOS 1.03 3H

-0.13 bobbin 18 14 9

14 DOS 0.68 2H 0

bobbin 18 14 9

15 DOS 0.42 2H 0.04 bobbin 18 14 9

16 DOS 0.36 2H

-0.02 bobbin 18 14 9

21 DOS 0.87 2H

-0.02 bobbin 18 14 9

37 SAI

=

0.31 1H

-0.03 Plus Point 38 OD 14 9

37 SAI 0.11 1H 0.01 Plus Point 38 OD 14 9

37 SAI 0.14 1H 0.06 Plus Point 38 OD 14 9

37 DIS 1.58 1 H

-0.06 bobbin 27

=

14 9

39 DOS 0.86 1H

-0.06 bobbin 26 14 9

40 DOS 0.32 1 H

-0.02 bobbin 26 14 9

55 SAI 0.36 1H

-0.16 Plus Point 78 OD 14 9

55 SAI 0.14 1H

-0.14 Plus Point 78 OD 14 9

55 DOS 1.11 I H

-0.04 bobbin 28 14 9

59 DOS 0.44 3H

-0.04 bobbin 28 14 9

59 DOS 0.21 5H

'-0.17 bobbin 28 14 9

65 SAI _

0.25 1H 0.07 Plus Point 71 OD 14 9

65 DOS 0.43 1H 0.13 bobbin 37 14 10 23 DOS 0.52 1H

-0.02 bobbin 19 14 10 35 SAI 0.11 1H 0.02 Plus Point 39 OD Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 14 10 73 DIS 1.15 3H

-0.19 bobbin 37 14 10 79 DOS 1.05 2H 0.09 bobbin 38 14 10 93 SAI 0.2 1H

-0.29 Plus Point 72 OD 14 11 3

VOL 0.2 2C

-0.07 Plus Point 75 OD 14 11 3

1WD 6

0.35 2C 0

bobbin 23

=

14 11 19 SAI 0.16 3H

-0.08 Plus Point 80 OD 14 11 19 DOS 0.42 1H 0.06 bobbin 18 14 11 19 DOS 0.42 3H

-0.26 bobbin 18 14 11 25 SAI 0.81 1H 0.02 Plus Point 80 OD 14 11 25 SAI 0.23 11H

-0.12 Plus Point 80 OD 14 11 25 DOS 1.25 11H 0.02 bobbin 16 14 11 46 SAI 0.41 1H

-0.01 Plus Point 80 OD 14 11 46 SAI 0.34 1H 0.09 Plus Point 80 OD 14 11 48 DOS 0.49 1 H

-0.11 bobbin 25 14 11 53 SAI 0.19 1H

-0.15 Plus Point 88 OD 14 11 53 DOS 1.04 1H

-0.25 bobbin 50 14 11 86 DOS 0.9 1H 0.04 bobbin 38 14 11 87 SAI 0.24 2H 0.02 Plus Point 68 OD Plugged SAI-OD @ 2H Wedge 14 12 14 SAI 0.14 3H

-0.03 Plus Point 80 OD.

14 12 14 DOS 0.7' 3H

-0.06 bobbin'; 17 14 12 32 SAI 0.22 1H

-0.05 Plus Point 38 OD 14 12 32 SAI 0.2 1H

-0.01 Plus Point 38 CD 14 12 43 SAI 0.12 1H 0

Plus Point 39 OD 14 12 58 DOS 0.97 1H 0.15 bobbin 27 14 12 72 SAI 0.27 1H 0.01 Plus Point 67 OD 14 12 72 DOS 0.44 1 H 0.06 bobbin 36 14 13 6

SAI 0.18 2H

-0.16 Plus Point 32 OD 14 13 6

SAI 0.36 2H

-0.03 Plus Point 32 OD 14 13 6

SAI 0.2 2H 0.07 Plus Point 32 OD 14 13 6

DOS 0.5 2H

-0.15 bobbin 17 14 13 10 SAI 0.12 2H

-0.09 Plus Point 32 OD 14 13 10 DIS 1.06 2H

-0.3 bobbin 17 14 13 15 DOS 0.55 3H

-0.11 bobbin 16 14 13 31 SAI 0.18 1H

-0.08 Plus Point 39 OD 14 13 32 DOS 0.82 1H 0.04 bobbin 17 14 13 48 DOS 0.65 2H

-0.02 bobbin 23 14 13 51 SAI 0.15 1H

-0.07 Plus Point 88 OD 14 14 7

SAI 0.13 2H

-0.11 Plus Point 80 OD 14 14 7

SAI 0.34 2H 0.06 Plus Point 80 OD 14 14 13 DOS 0.27 3H

-0.02 bobbin 15 14 14 19 SAI 0.14 3H

-0.16 Plus Point 80 OD 14 14 34 SAI 0.72 1H

-0.07 Plus Point 40 OD Plugged SAI-OD, >2v DOS @ 1H 14 14 34 DOS 2.13 1H 0.06 bobbin 49 Plugged SAI-OD, :2v DOS @ 1H 14 14 36 SAI 0.49 1H 0.06 Plus Point 40 OD Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal ID/OD Tube Status Reason for Repair 14 14 36 DOS 0.99 1H -0.26 bobbin 15 14 14 40 DOS 0.33 2H 0

bobbin 15 14 14 42 DOS 0.27 2H -0.02 bobbin 13

=

14 14 47 DOS 0.56 1H 0

bobbin 13

=

14 14 47 DOS 0.26 4H

-0.06 bobbin 13 14 15 7

SAI 0.15 1H 0.27 Plus Point 33 OD 14 15 22 TWD 11 0.15 7H 38.67 bobbin 14 14 15 29 SAI 0.38 1H

-0.01 Plus Point 40 OD 14 15 36 SAI 0.2 1H -0.09 Plus Point 41 OD 14 15 47 SAI 0.31 1H -0.16 Plus Point 40 OD Plugged SCI-OD @ TSH 14 15 47 SCI 0.24 TSH 0.12 Plus Point 40 OD Plugged SCI-OD @ TSH 14 15 47 DIS 0.87 1H 0.04 bobbin 12 Plugged SCI-OD @ TSH 14 15 85 SAI 0.16 1H -0.15 Plus Point 65 OD 14 15 85 DOS 0.74 1H -0.02 bobbin 31 14 16 38 DOS 0.18 2H

-0.04 bobbin 13 14 16 39 DOS 0.23 2H

-0.02 bobbin 14 14 16 58 DOS 0.52 2H 0.13 bobbin 34 14 16 59 DOS 0.17 1H 0

bobbin 34 14 16 60 DOS 0.69 1H 0.07 bobbin 34

, I.

14 16 60 DOS I 0.75 2H

-0.02 bobbin 34 14 16 62 DOS 0.31 2H 0.06 bobbin 34 14 16 65 SAI 0.12 2H 0.16 Plus Point 76 OD 14 16 65 DIS 0.77 2H 0.32 bobbin 34 14 16 66 SAI 3.46 TEH 0.81 Plus Point 77 ID 14 16 66 SAI I 2.66 TEH 0.87 Plus Point 77 ID 14 16 66 SAI 2.2 TEH 1.2 Plus Point 77 ID 14 16 66 SAI 1.89 TEH 1.19 Plus Point 77 ID 14 16 66 SAI 3.1 TEH 1.47 Plus Point 77 ID 14 16 66 SAI 1.41 TEH 1.74 Plus Point 77 ID 14 16 66 SAI 1.65 TEH 1.75 Plus Point 77 ID 14 16 66 SAI 2.12 TEH 1.76 Plus Point 77 ID 14 16 66 SAI 1.47 TEH 1.94 Plus Point 77 ID 14 16 66 SAI 1.02 TEH 1.94 Plus Point 77 ID 14 16 66 SAI 1.09 TEH 0.77 Plus Point 77 ID 14 16 66 DOS 0.71 1H

-0.18 bobbin 34 14 16 68 DOS 0.84 1H 0.13 bobbin 34

=

14 16 69 SAI 0.1 2H

-0.26 Plus Point 65 OD 14 17 4

TWD 8

0.51 2C

-0.15 bobbin 14 14 17 6

TWD 10 0.65 2C

-0.04 bobbin 15 14 17 24 SAI 0.29 1H 0.39 Plus Point 30 ID 14 17 32 SAI 0.42 1H -0.13 Plus Point 40 OD 14 17 41 DOS 0.51 5H -0.17 bobbin 13 14 17 46 DOS 0.36 4H

-0.06 bobbin 12

=

14 17 75 SAl 0.19 I1H -0.07 Plus Point 66 CD Plugged AONDB @ >5v Dent i

Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %/.TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 14 17 76 SAI 0.3 1H 0

Plus Point 65 OD 14 17 76 DOS 0.7 1H 0.09 bobbin 31 14 18 6

TWD 7

0.45 2C 0.06 bobbin 14 14 18 22 DOS 0.45 2H 0.02 bobbin 15 14 18 27 SAI 0.18 1H 0.06 Plus Point 41 OD Plugged AONDB @ >5v Dent 14 18 50 DOS 1.58 11H

-0.1 bobbin 47 i__

14 18 76 DOS 0.3 11H 0.09 bobbin 32

=

14 18 79 DOS 0.23 1H 0.06 bobbin 31 14 19 32 SAI 0.57 1H

-0.01 Plus Pointl 41 OD 14 19 32 DIS 1

1H

-0.32 bobbin 12 14 19 40 SAI 0.16 1H 0.07 Plus Point 41 OD 14 19 45 SAI 0.29 1H

-0.02 Plus Point 80 OD 14 19 45 SAI 0.27 1H

-0.07 Plus Point 80 OD 14 19 45 SAI 0.22 2H

-0.12 Plus Poinl 40 OD 14 19 45 DOS I 1.22 1 H

-0.04 bobbin 12

=

14 19 47 DOS 0.29 1 H 0.02 bobbin 12

=

14 20 25 SAI 0.24 1H

-0.69 Plus Point 30 ID 14 20 25 DIS 2.16 1H

-0.32 bobbin 13 14 20 63 SAI 2.22 TEH 0.8 Plus Pointl 76 ID 14 20 63 SAI 0.93 TEH 0.76 Plus Point 76 ID 14 20 63 SAI 0.88 TEH 0.72 Plus Point 76 ID 14 20 63 SAI 1.12 TEH 1.09 Plus Point 76 ID 14 20 63 SAI 1.09 TEH 1.07 Plus Point 76 ID 14 20 63 SAI 0.58 TEH 1.47 Plus Point 76 ID 14 20 63 SAI 0.48 TEH 1.38 Plus Point 76 ID 14 21 51 SAI 0.13 1H

-0.12 Plus Point 76 OD 14 21 67 SAI 0.73 5H

-0.17 Plus Point 30 ID 14 21 67 DIS 0.51 5H

-0.06 bobbin 33

=

14 21 76 SAI 0.59 1H

-0.12 Plus Point 30 ID 14 21 76 DIS 0.82 1H

-0.26 bobbin 31 14 21 84 SAI 0.68 1H 0.06 Plus Point 83 ID 14 21 84 DIS 0.38 1H 0.11 bobbin 31 14 22 8

SAI

_I_

0.42 1H

-0.19 Plus Point 80 OD 14 22 8

DOS 0.98 11H

-0.08 bobbin 15 14 22 32 DOS 0.43 2H 0

bobbin 13 14 22 34 SAl 0.28 1H

-0.05 Plus Point 80 OD 14 22 34 DOS 0.48 1H

-0.09 bobbin 13 14 22 38 DOS 0.24 1H

-0.06 bobbin 13 14 22 40 DOS 0.24 2H 0.02 bobbin 13 14 22 43 SAI

=

0.18 1H

-0.02 Plus Point 42 OD 14 23 7

SAI 0.4 TSH -8.11 Plus Point 30 ID 14 23 73 SAI 0.36 1H 0.08 Plus Point 61 OD Plugged AONDB @ >5v Dent 14 24 13 TWD 6

0.35 2C

-0.09 bobbin 15 14 24 16 DOS 0.35 1 H

-0.04 bobbin 15 Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal ID/OD Tube Status Reason for Repair 14 24 54 DOS 0.35 2H 0

bobbin 34 14 24 56 TWD 12 0.17 7H 44.14 bobbin 34 14 24 62 SAI 0.24 1H 0

Plus Point 76 OD 14 24 75 SAI 0.22 1H 0.14 Plus Point 62 OD I 14 24 75 DOS 0.2 1H 0.09 bobbin 32

=

14 25 23 DOS 0.69 1H 0.09 bobbin 14 14 25 26 SAl 1.54 2H

-0.06 Plus Point 80 OD Plugged SAI-OD, >2v DOS @ 2H 14 25 26 DOS 3.55 2H 0

bobbin 49 Plugged SAI-OD, >2v DOS a 2H 14 25 31 SAI 2.32 1H

-0.08 Plus Point 80 OD Plugged SAI-OD, >2v DOS a 1H 14 25 31 DOS 3.64 1H

-0.02 bobbin 49 Plugged SAI-OD, >2v DOS @ 1H 14 25 36 SAI 0.18 1H 0

Plus Point 43 OD 14 25 60 SAI 0.61 1H

-0.01 Plus Point 76 OD 14 25 60 DOS 1.05 1H 0.06 bobbin 33 14 26 9 TWD 10 0.15 7H 66.39 bobbin 7

=

=

14 26 12 DOS 0.42 1H 0

bobbin 8

=

14 26 13 DOS 0.74 2H 0.02 bobbin 9

=

14 26 20 DOS

=

1.26 4H 0.06 bobbin 9

=

14 26 36 SAI 0.15 1H

-0.12 Plus Point 80 OD 14 26 36 DOS 0.51 1H

-0.11 bobbin 7

14 26 37 SAI 1

6H 0.17 PlusPoint 30 ID 14 26 37 DIS 0.67 6H 0.08 bobbin 7

14 26 56 TWD 25 0.52 7H 87.56 bobbin 25 14 26 61 TWD 9

0.12 7H 31.64 bobbin 25 14 26 80 DOS 0.56 1H 0.06 bobbin 29 14 27 11 TWD 14 0.87 2C

-0.02 bobbin 7

14 27 12 TWD 11 0.72 2C 0

bobbin 7

14 27 34 SAI 0.59 1H 0.07 Plus Point 45 OD

=

14 27 34 SAI 0.24 4H

-0.07 Plus Point 80 OD 14 27 34 SAI 0.15 4H

-0.09 Plus Point 80 OD 14 27 34 SAI 0.18 5H

-0.13 Plus Point 80 CD 14 27 34 DOS 1.02 1H 0.08 bobbin 10 14 27 34 DOS 0.97 4H 0.02 bobbin 10 14 27 34 DOS 0.41 5H

-0.06 bobbin 10 14 27 35 DOS 0.48 1 H

-0.02 bobbin 8

14 27 36 SAI 0.22 4H

-0.19 Plus Point 80 OD 14 27 36 DOS 0.77 4H

-0.11 bobbin *8

=

14 27 40 DOS 0.33 1H 0

bobbin 6

14 27 42 DOS 0.36 1K 0.04 bobbin 6

=

14 27 55 DOS I 1.16 1KH 0.11 bobbin 26

=

=

14 27 76 TWD 10 0.14 7H 47.92 bobbin 28 14 27 76 TWD 7

0.09 7H 70.55 bobbin 28

=

14 28 12 TWD 18 1.2 2C 0.02 bobbin 9

14 28 45 DOS 0.35 4H

.0.02 bobbin 5

14 28 57 SAI 0.28 TSH -2.88 Plus Point 30 ID Enclosure PG&E Letter DCL-05-028 Table 2 Location and PercentThrough-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal ID/OD Tube Status Reason for Repair 14 28 57 SAI

=

0.38 TSH -7.07 Plus Point 30 ID 14 28 63 SAI 0.21 1H 0.1 Plus Point 83 OD 14 28 63 SAI 0.24 1H 0.01 Plus Point 83 OD 14 28 63 DOS 0.82 1H 0.13 bobbin 27

=

14 29 34 TWD 26 0.63 7H 95.47 bobbin 10 14 29 34 TWD 19 0.35 7H 75.36 bobbin 10 14 29 34 TWD 17 0.28 7H 31.99 bobbin 10 14 29 57 SAI

=

0.22 2H

-0.13 Plus Point 83 OD 14 29 57 DOS

=

1.3 2H

-0.17 bobbin 26

=

14 29 78 SAI 0.24 1H 0.03 Plus Point 83 OD Plugged SAI-OD @ 1HWedge 14 29 78 DOS 0.68 1 H 0.02 bobbin 28 Plugged SAI-OD @ I H Wedge 14 30 59 SAI 0.26 1H

-0.18 Plus Point 57 OD 14 30 59 DIS 1.52 1 H

-0.09 bobbin 25 14 30 59 DIS 0.72 4H 0

bobbin 25 14 30 61 SAI 0.13 3H

-0.26 Plus Point 57 OD Plugged AONDB @ >5v Dent 14 30 76 TWD 10 0.14 7H 52.42 bobbin 27 I

14.

31 34 TWD 16 0.27 7H 102.4 bobbin 10

=

14 31 34 TWD 25 0.58 7H 80.38 bobbin 10

=

=

14 31 34 TWD 20' 0.38 7H 53.99 bobbin 10

=

14 31 42 TWD 12 0.22 7H 56.17 bobbin 6

14 31 42 TWD 16 0.31 7H 35.21 bobbin 6

=

14 31 55 TWD 24 0.5 7H 54.81 bobbin 26 14 31 55 TWD 32 0.98 7H 79.48 bobbin 26 14 31 55 TWD 12 0.15 7H 107.8 bobbin 26

=

14 31 64 TWD 12 0.18 7H 53.53 bobbin 28 14 31 67 TWD 14 0.21 7H 79.57 bobbin 28 14 31 67 TWD 21 0.41 7H 80.5 bobbin 28 14 31 67 TWD 14 0.22 7H 107.5 bobbin 28 14 31 72 TWD 12 0.17 7H 106.7 bobbin 27 14 32 22 SAI 0.13 2H

-0.15 Plus Point 80 OD Plugged SAI-CD @ 2H Wedge 14 32 22 SAI 0.21 2H 0

Plus Point 80 OD Plugged SAI-OD @ 2H Wedge 14 32 22 DOS

=

0.32 2H 0.02 bobbin 7

=

Plugged SAI-OD @ 2H Wedge 14 32 24 DOS

=

0.3 1H 0.06 bobbin 9

=

14 32 25 DOS 0.25 4H

-0.11 bobbin 10 14 32 26 DOS 0.41 2H 0

bobbin 10 14 32 28 DOS 1.27 1 H 0.02 bobbin 11 14 32 36 TWD 30 0.86 7H 56.21 bobbin 7

14 32 36 TWD 17 0.28 7H 34.81 bobbin 7

14 32 43 TWD 24 0.55 7H 102.8 bobbin 5

14 32 49 DOS =

0.34 1 H 0.06 bobbin 3

=

14 32 62 TWD 10 0.14 7H 111.3 bobbin 28

=

14 33 16 TWD 16 1.08 2C

-0.11 bobbin 7.

14 33 33 TWD 10 0.18 7H 85.62 bobbin 11 14 33 33 TWD 11 0.2 7H 110 bobbin 11 Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Cot Ind %TW Volts Loc Inch Probe Cal ID/OD Tube Status Reason for Repair 14 33 53 TWD 15 0.22 7H 34.94 bobbin 26 14 33 55 SAI 0.33 1H 0

Plus Point 84 OD 14 33 55 DOS 0.37 1H 0.09 bobbin 26 14 33 58 SAI 0.57 1H 0.03 Plus Point 55 OD 14 34 32 TWD 13 0.2 7H 58.77 bobbin 10 14 34 41 SAI 0.14 2H 0

Plus Point 47 OD Plugged AONDB @ >5v Dent 14 34 52 SAI 0.32 1H 0.01 Plus Point 84 OD 14 34 52 DOS 0.45 1H 0.06 bobbin 26 14 34 53 SAI I

1H 0.06 Plus Point 83 OD Plugged SAI-OD, >2v DOS @ 1H 14 34 53 DOS 2.06 1H 0.13 bobbin 25 Plugged SAI-OD, >2v DOS @ IH 14 34 54 SAI 0.26 1H

-0.01 Plus Point 55 OD Plugged AONDB @ >5v Dent 14 34 67 SAI 0.28 1H 0.04 Plus Point 83 OD 14 34 67 SAI 0.26 1H

-0.05 Plus Point 83 OD 14 34 67 DOS 0.39 1H 0.07 bobbin 27 14 35 20 TWD 22 1.46 2C

-0.07 bobbin 7

14 35 21 TWD 10 0.65 2C

-0.06 bobbin 7

14 35 22 TWD 14 0.88 2C

-0.02 bobbin 9

14 35 36 SAI 0.41 2H 0.25 Plus Point 30 ID 14 35 36 SAI 1.7 TEH 0.73 Plus Point 80 ID 14 35 36 SAI 1.95 TEH 0.77 Plus Point 80 ID 14 35 36 SAI 1.83 TEH 0.8 Plus Point 80 ID 14 35 36 SAI 0.91 TEH 1.48 Plus Point 80 ID 14 35 36 SAI 1.21 TEH 1.44 Plus Point 80 ID 14 35 36 SAI

=

1.25 TEH 1.39 Plus Point 80 ID 14 35 36 SAI 1.89 TEH 1.52 Plus Point 80 ID 14 35 36 SAI 1.26 TEH 1.74 Plus Point 80 ID 14 35 44 TWD 32 1.09 7H 37.03 bobbin 5

=

14 35 53 TWD 31 0.9 7H 60.47 bobbin 26 14 35 53 TWDN 17 0.26 7H 121.8 bobbin 26 14 35 56 SAI 0.24 3H

-0.08 Plus Point 30 ID 14 35 56 SAI 0.43 3H 0.09 Plus Point 30 ID 14 35 56 DIS 0.06 3H 0.13 bobbin 26 14 35 58 TWD 35 2.04 7H 60.2 bobbin 49 14 35 58 TWD 21 0.36 7H 33.05 bobbin 26 14 35 58 TWD 12 0.17 7H 90.11 bobbin 26 14 35 61 SAI 0.31 2H

-0.02 Plus Point 30 ID 14 35 65 TWD 17 0.29 7H 36.39 bobbin 28 14 35 65 TWD 30 0.87 7H 59.81 bobbin 28 14 35 65 TWD 21 0.43 7H 89.87 bobbin 28 14 35 66 TWD 17 0.29 7H 36.22 bobbin 27 14 35 66 TWD 30 0.81 7H 59.84 bobbin 27 14 35 66 TWD 22 0.45 7H 90.14 bobbin 27

=

14 35 68 SAI 0.47 3H

-0.12 Plus Point 30 ID 14 35 68 DIS 0.34 3H

-0.06 bobbin 28 Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Cot Ind

%TW Volts Loc Inch Probe Cal ID0OD Tube Status Reason for Repair 14 36 19 TWD 14 0.89 2C

-0.13 bobbin 9

14 36 46 TWD 27 0.64 7H 119.4 bobbin 3

14 36 47 SAI 0.28 1H 0.1 Plus Point 47 OD 14 36 52 TWD 40 2.76 7H 91.92 bobbin 49

=

Plugged 40%TW AVB Wear 14 36 52 TWD 32 1.02 7H 63.08 bobbin 26

=

Plugged 40%TW AVB Wear 14 36 52 TWD 28 0.66 7H 124.4 bobbin 26 Plumed 40%TW AVB Wear 14 36 57 TWD 25 0.51 7H 33.99 bobbin 25 14 36 57 TWO 24 0.5 7H 61.68 bobbin 25 14 36 59 TWD 14 0.2 7H 93.53 bobbin 25 14 36 61 TWD 25 0.5 7H 122.9 bobbin 25 14 36 61 TWD 23 0.46 7H 123.9 bobbin 25 14 36 61 TWD 36 1.25 7H 93.02 bobbin 25 14 36 61 TWD 35 2.04 7H 61.44 bobbin 49 14 37 20 VOL 0.18 2C 0.01 Plus Point 73 OD 14 37 20 TWD 5 0.28 2C 0.04 bobbin 7

14 37 37 DOS 0.43 2H 0.04 bobbin 7

14 37 53 TWD 26 0.55 7H 37.36 bobbin 25 14 37 53 TWO 15 0.23 7H 64.01 bobbin 25 14 37 53 TWD 33 1.02 7H1 95 -

bobbin 25 14 37 53 TWD 16 0.24 '7H 127.9 bobbin 25 14 37 54 TWO 10 0.14 7H 95.11 bobbin 25.

14 37 60 TWD 12 0.17 7H 36.87 bobbin 25 14 37 66 TWD 16 0.27 7H 37.34 bobbin 27 14 37 66 TWD 20 0.38 7H 63.28 bobbin 27 14 37 66 TWD 10 0.14 7H 95.17 bobbin 27 14 38 21 TWD 18 1.18 2C

-0.11 bobbin 7

14 38 62 TWO 8

0.12 7H 130.4 bobbin 28 14 38 69 SAI 0.51 2H 0.02 Plus Point 30 ID 14 38 69 DIS 0.36 2H

-0.18 bobbin 27 14 38 72 SAI 0.42 1H 0.36 Plus Point 30 ID 14 39 23 TWD 12 0.74 2C

-0.07 bobbin 7

14 39 48 SAI 0.32 3H 0.17 Plus Point 30 ID 14 39 48 SAI 3.05 TEH 0.8 Plus Point 80 ID 14 39 48 SAI 0.92 TEH 0.88 Plus Point 80 ID 14 39 48 SAI 3.66 TEH 0.84 Plus Point 80 ID 14 39 48 SAI 3.16 TEH 0.84 Plus Point 80 ID 14 39 48 SAI 0.73 TEH 1.35 Plus Point 80 ID 14 39 48 SAl 0.85 TEH 1.56 Plus Point 80 ID 14 39 48 SAI 2.8 TEH 1.52 Plus Pointl 80 ID 14 39 48 SAI 0.61 TEH 1.6 Plus Point 80 ID 14 39 48 SAI 3.29 TEH 1.61 Plus Point 80 ID 14 39 48 SAI 1.31 TEH 1.78 Plus Point 80 ID 14 39 48 DIS 0.83 3H

-0.19 bobbin 4

14 39 58 SAI

=

1H 0.29 PIus PointM 30 ID Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %/oTW Volts Loc Inch Probe Cal ID/OD Tube Status Reason for Repair 14 39 58 SAI 2.27 TEH 0.66 Plus Point 76 ID 14 39 58 SAI 3.24 TEH 0.8 Plus Point 76 ID 14 39 58 SAI 2.66 TEH 0.93 Plus Point 76 ID 14 39 58 SAI 3.1 TEH 1.29 Plus Point 76 ID 14 39 58 SAI

=

.67 TEH 1.39 Plus Point 76 ID 14 39 58 SAI 4.12 TEH 1.56 Plus Point 76 ID 14 39 58 SAI 3.24 TEH 1.69 Plus Point 76 ID 14 39 58 SAI 0.33 TEH 15.4 Plus Point 76 ID 14 39 58 DIS 1.19 1H 0.34 bobbin 26 14 39 58 TWD 12 0.17 7H 36.26 bobbin 26 14 39 58 TWD 30 0.78 7H 100.3 bobbin 26 14 39 58 TWD 18 0.28 7H 133.7 bobbin 26 14 39 58 DTS 16.1 TEH 0.42 bobbin 26 14 39 58 DTS

=

17.99 TEH 1.24 bobbin 26

=

14 39 66 SAI 0.29 1H 0

Plus Point 51 OD 14 39 66 SAI 0.2 2H 0.01 Plus Point 83 OD 14 39 66 DOS 0.64 1H 0.02 bobbin 27 14 39 66 DOS 0.44 2H 0.02 bobbin 27 14

40.

60 VOL 0.19 7H 102 Plus Point 82 OD 14 401 60 TWD 11 0.14 7H 102.9 bobbin 25 14 40 63 TWD 13 0.2 7H 68.01 bobbin 27 14 40 63 TWD 16 0.25 7H 68.27 bobbin 27 14 40 63 TWD 13 0.19 7H 102.9 bobbin 27 14 40 64 SAI

=

0.2 1H 0.07 Plus Point 83 OD 14 40 64 DOS 0.31 1H 0.17 bobbin 27 14 40 64 TWD 23 0.48 7H 68.12 bobbin 27

=

14 40 64 TWD 35 1.17 7H 103.1 bobbin 27

=

14 40 66 TWD 10 0.14 7H 102.7 bobbin 28 14 41 61 TWD 10 0.13 7H 105.6 bobbin 26 14 41 63 TWD 17 0.3 7H 69.64 bobbin 28 14 41 63 TWD 14 0.21 7H 105.6 bobbin 28 14 42 28 DOS 0.21 1H -0.06 bobbin 11 14 42 54 SAI I_

I 0.11 1H 0.06 Plus Point 51 OD 14 42 59 TWD 12 0.17 7H 143.1 bobbin 25 14 42 61 TWD 31 0.81 7H 70.72 bobbin 25 14 43 37 TWD 9

0.13 7H 73.11 bobbin 7

14 43 42 SAI 0.22 1H -0.19 Plus Point 80 OD 14 43 42 DOS 0.16 1H -0.09 bobbin 6

14 43 46 TWD 8

0.15 7H 143.6 bobbin 4

14 43 49 DOS

=

0.29 2H -0.09 bobbin 4

=

14 43 53 DOS 1.11 1H 0

bobbin 25 14 43 56 TWD 35 2.01 7H 145.8 bobbin 49 14 43 56 TWD 32 0.95 7H 146.3 bobbin 26

=

14 43 56 TWD 37 1.59 7H 110.3 bobbin 26

=

1.-

'14 Enclosure PG&E Letter DCL-05-028 Table 2 Location and Percent Through-Wall of Indications Identified During 1R12 SG Row Col Ind %TW Volts Loc Inch Probe Cal IDIOD Tube Status Reason for Repair 14 43 57 SCI 0.24 1H 0.3 Plus Point 52 OD Plugged SCI-ODQ 1H 14 43 57 TWD 30 0.77 7H 145.6 bobbin 25 Plugged SCI-OD @ 1H 14 43 57 TWD 36 1.26 7H 110.6 bobbin 25

=

Plug ed SCI-OD @ 1H 14 43 59 TWD 12 0.17 7H 110.7 bobbin 26 9

14 43 65 VOL

=

0.45 7H 108.4 Plus Point 82 OD 14 43 65 TWD 31 1.03 7H 109.8 bobbin 28 14 44 34 VOL

=

0.76 2C

-0.04 Plus Point 81 OD 14 44 34 TWD 21 1.38 2C

-0.06 bobbin 11 14 44 57 TWD 10 0.64 2C

-0.04 bobbin 26 14 44 58 TWD 10 0.13 7H 74.32 bobbin 25 14 45 53 DOS 0.46 1H 0.07 bobbin 26 14 45 54 DOS 0.34 2C

-0.28 bobbin 30 14 45 56 DIS 0.78 4H

-0.17 bobbin 26

=

14 45 58 VOL 0.39 7H 114.9 Plus Point 82 OD 14 45 58 TWD 27 1.9 2C

-0.17 bobbin 26 14 45 58 TWD 26 0.58 7H 115.9 bobbin 26 14 46 42 SAI 0.4 1H

-0.08 Plus Point 30 ID 14 46 42 DIS 0.62 1H

-0.21 bobbin 11 14 46 44 SAI 0.39 1H

-0.03 Plus Point 80 OD 14 46 44 DOS 0.51 1H 0

bobbin 11 14 46 48 DOS

=

0.6 1H

-0.02 bobbin 11 I=

I