ML050830409

From kanterella
Jump to navigation Jump to search
E-Mail H. Chernoff, NRR, to L. Raghavan, NRR, Et Al., Point Beach Unit 1 Rvp Bottom Head Repair Issue
ML050830409
Person / Time
Site: Point Beach 
(DPR-024)
Issue date: 05/26/2004
From: Chernoff H
NRC/NRR/DLPM/LPD3
To: Raghavan L
NRC/NRR/DLPM
References
FOIA/PA-2004-0282
Download: ML050830409 (1)


Text

'Iadf-thernoff - Fwd: Point Beach Unit 1iRPV Bottom Head Repair Issue Paae 1 y:

From:

To:

Date:

Subject:

Harold Chernoff

\\

Lakshminaras Raghavan; Tad Marsh; William Ruland/ )

K Wed, May 26, 2004 6:57 AM Fwd: Point Beach Unit 1 RPV Bottom Head Repair Issue Follow-up and closure of the subject issue identified yesterday is attached.

In summary, the licensee identified condition report does not identify a condition adverse to quality or non-compliant with ASME code. No further action is warranted.

Harold Chernoff, Project Manager - Point Beach Project Directorate 111-1 Division of Licensing Project Management Office of Nuclear Reactor Regulation Office: (301) 415-4018 Fax: (301) 415-1222 CC:

hkc

/

,6 -.; q