To R-1109298-01, Analysis of Control Room X/Q Values for Releases at the Indian Point Generating Station Unit Number 3 Using the ARCON96 Computer Code
ML050550214
Person / Time
Site: Indian Point 
Issue date: 02/02/2005
From:
ABS Consulting
To:
Office of Nuclear Reactor Regulation
References
R-1109298-01, Rev 4
Download: ML050550214 (26)


Text

ANALYSIS OF CONTROL ROOM y/O VALUES FOR RELEASES AT THE INDIAN POINT GENERATING STATION UNIT NUMBER 3 USING THE ARCON96 COMPUTER CODE ABS CONSULTING REPORT R-1 109298-01, REVISION 4 2 FEBRUARY 2005

I, tADS Consulting APPROVAL COVER SHEET

Title:

Analysis of Control Room x/Q Values for Releases at the Indian Point Generating Station Unit llumber3 Using the ARCON96 Computer Code Report lumber.

R-1109298-C1 Client:

Entergy Nuclear Northeast P1foJect:

Analysis of Control Room XIQ Values for Indian Point Generating Station Unit Number 3 kovishIn Approval Wumb')r Date Prepared Reviewed Approved T. Edward 0

9118102 Fenstermacher Jackie Lewis Keith Woodard 1

1,214/02 T. Edwardc Jackie Lewis Mark Abrams T. Edward 2

/10)05 Fensterracher Jackie Lewis Keith Woodard T. Edward 3

1/24/05 Fenstermacher Jackie Lewis Keith Woodard 4

R-1109298M1,Fcv 4 Page o2f 26 2 February 2005

Tabl e Revision 0 Revision 1 Revision 2 Revision 3 Revision 4 of Revisions Date: 18 September 2002 Original Issue Date: 4 December 2002 Revised to include title page, table of revisions, summary, clarify reference for ARCON96, add reference for WK2ARCON, add reference for meteorological data, clarify reference for units of meteorological data.

Date: 10 January 2005 Revised to replace Table 1, which had erroneous values for the coordinates for the Auxiliary Boiler Feed Building. The spelling of "Auxiliary" was corrected in several places Date: 24 January 2005 Revised to replace Auxiliary Boiler Feed Building fan release point with organ pipe and silencer release points. Also, corrected height and size of containment vent release.

Date: 2 February 2005 Revised to correct release height from silencer from 133' 13/4" to 113' 13/4" R-1 109298-01, Rev. 4 Page 3 of 26 2 February 2005

Summary The X/Q values for the meteorological dispersion between several release points and the Indian Point 3 control room intake were determined using the ARCON96 computer code. The release points considered were the containment vent, the containment surface, the side of the auxiliary boiler feed building, the auxiliary boiler feed building atmospheric dump valve silencers, and the auxiliary boiler feed building safety valve organ pipes. Release periods of 0 hours0 days <br />0 hours <br />0 weeks <br />0 months <br /> to 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />, 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> to 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />, 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, 1 day to 4 days, and 4 days to 30 days were calculated.

The X/Q values were highest for the auxiliary boiler feed building organ pipes, followed by the side of the auxiliary boiler feed building, the auxiliary boiler feed building silencers, and the containment vent. The X/Q values were lowest for the containment surface release.

R-I 109298-01, Rev. 4 Page 4 of 26 2 February 2005

Table of contents Approval Cover Sheet.........................

2 Table of Revisions............

3 Summary 4

Table of Contents 5

Introduction 6

Input Data 6

Methodology.........................

8 Results 9

References.........................

9. ARCON96 Log Files.........................

1.1 R-1 109298-01, Rev. 4 Page 5 of.26 2 February 2005

Introduction ABS Consulting engineers have used the ARCON961 computer code to analyze the X/Q values at the control room intake for releases at Unit 3 of the Indian Point Generating Station. Pacific Northwest National Laboratory developed ARCON96 for the United States Nuclear Regulatory Commission. The purpose of the code is to determine the X/Q values at receptors on or near buildings from releases on or near buildings for various averaging times. It includes corrections for building wakes, low wind speeds, elevated and vent releases, and area releases.

Input Data ARCON96 requires the use of hourly meteorological data for a period of at least one year. This data must include the wind direction, wind speed, and stability class; and may optionally include wind direction and wind speed for a second meteorological instrument at another height. The meteorological data used for this analysis was collected at the Indian Point Generating Station in 1995, 1996, and 19972. ABS Consulting received the data on diskettes and a program was written to extract the data to the format required by ARCON96 3. The wind instruments at heights of 10 m and 60 m were used. Wind speed in the unconverted data has units of miles per hour for wind speed and 'F for temperature and temperature difference measurements4. The converted file retains the wind speed units as miles per hour, while the temperature differences are converted to stability classes A to G.

ARCON96 also requires data on the source and receptor locations, as well as other geometric data, flow data, and the initial plume dimensions. For the source, the code requires that the release be specified as a ground, vent, or stack release. If the release is well above the attached building, it is a stack release. If it is not a stack release, but is released with a large enough vertical velocity, ARCON96 treats it as a vent release. The code treats releases from the surface of the building without vertical velocity as ground releases. The model also requires the release height, building area, vertical velocity, stack flow (volumetric flow rate), and stack radius. The building area was taken to be the lateral area of the containment building. The receptor data includes the distance from the source, the direction from the source, the intake height, and the elevation difference if the source and receptor are measured from different reference planes.

ARCON96 also requires the initial plume dimensions for area releases. The determination of these values will be discussed below. There are several other input values, but they did not need to be altered from their default values for this analysis.

The ARCON96 analysis for the Indian Point Nuclear Plant required calculation of X/Q values for five locations: a containment surface leak, a release from the containment vent, the side of the auxiliary boiler feed building, the auxiliary boiler feed building safety valve organ pipes, and the auxiliary boiler feed building atmospheric dump valve silencers. Instructions on determining the locations of the release points and the control room intake were taken from Letter NEA-05-0025.

We took the information used to determine the location and size of the containment surface leak (described in the next paragraph) from U.E. & C. drawing 9321 -F-13 1936 and the receptor location (the point on the surface closest to the control room intake was chosen). The height of the containment vent was taken from the same drawing, and the horizontal coordinates were taken from drawing C0047. The locations of the auxiliary boiler feed building safety valve "organ pipes" were taken from drawing 9321-F-20493 8 for the horizontal coordinates and from drawing 9321-F-205039 for the elevation. The location of the silencers was taken from Con Ed Drawing A210148-l'o The location of the intersection of the shield wall and the containment (the closest point on the auxiliary feed pump building south wall to the control room intake) was taken from drawings C0047 and 9321-F-40433-5 11, and the dimensions of the blowout panels from Drawing 9321-F-14853'2. The location of the control room intake was taken from drawing 932 1-F-R-1 109298-01, Rev. 4 Page 6 of 26 2 February 2005

4017313. These values were then used to determine the distance from the source to the receptor, and with a correction from plant north to true north, for the direction to the source. The grade elevation, used to determine the height of the source and receptor locations above the ground, was taken to be the top of the paved area South and West of the containment on drawing C004.

The ARCON96 manual states that, "Methods for determining the initial diffusion coefficients that define a virtual source involve subjective decisions." Numerical integration over the part of the surface available for release, (that is, above the adjoining buildings where present), was used to determine the effective distance and height of the containment surface release. The heights and locations of the adjoining buildings (i.e., the electrical tunnel, auxiliary feed pump building, and fan house) were taken from drawings 9321-F-1536314 and 9321-F-40433-5 1. The initial plume standard deviations used were equal to one-sixth of the width and available height of the containment. For the release from the side of the auxiliary boiler feed, the intersection of the containment and the shield wvall was the closest point to the control room intake, and was used for the release. The initial plume dimensions for that case were one sixth of the height and average width of the blowout panels on the south side of the building, projected onto a vertical plane perpendicular to the line of sight from the release point to the control room intake.

The auxiliary boiler feed building safety valve organ pipes were modeled using the closest point on the organ pipe that is closest to the control room intake, and was modeled as a point release. The auxiliary boiler feed building atmospheric dump valve silencers were modeled using the closest point on the silencer that is closest to the control room intake, and was modeled as a point release. The containment vent release was modeled at the center of the vent. The initial horizontal plume dimension for vent releases is the equivalent vent diameter divided by six. Table I shows the source and receptor locations, Table 2 shows the geometric input data locations, and Table 3 shows the flow and initial plume size data, and Table 4 shows miscellaneous input data.

Position, ft Location N

J E

j Elevation Containment Surface 5997.0 1475.1 150.1 Containment Vent 6023.0 1475.0 268.0 Auxiliary Boiler Feed Building Side 5991.7 1410.1 66.5 Auxiliary Boiler Feed Building Organ Pipes 5995.5 1395.6 97.0 Auxiliary Boiler Feed Building Silencers r 6012.9 1390.1 113.1 Control Room Intake l

5783.8 1476.0 25.5 Table 1. Source and receptor locations on plant grid.

Distance Direction to Intake to Release Release Building Receptor Height Source Type Height Area Location m

0 D

Flag m

m2 Containment Surface l

65.01l 2.29 38.32 1

40.25 3059.33 Containment Vent 72.92 2.29 38.32 1

76.21 3059.33 Auxiliary Boiler Feed Building Side 866.48 2.29 20.98 1

14.78 3059.33 Auxiliary Boiler Feed Building Organ Pipes 68.84 2.29 17.76 1

24.08 3059.33 Auxiliary Boiler Feed Building Silencersl 73.7 2.29 18.01 1

29.0t 3059.33 Table 2. ARCON96 geometric input data.

R-1 109298-01, Rev. 4 Page 7 of 26 2 February 2005

Methodology We prepared the input data on a Microsofte Excel spreadsheet. A Visual Basice macro translated the data from the spreadsheet into input files for ARCON96, and wrote a batch file to run the cases. The batch file invoked ARCON96 to run the individual cases and produce the required output. Another Visual Basics macro read the data back into the spreadsheet. The results for the individual cases were printed and used to verify that the input and output data agreed with the values on the spreadsheet.

Initial Plume Vertical Stack Stack Dimensions Velocity Flow Radius m

Location M/s m3 /s m

ay l.

Containment Surface 0.0( 0.00 0.0o 7.32 13.31 Containment Vent 0.0(

0.

0.00 0.2 0.00 Auxiliary Boiler Feed Building Side 0.0(

0.00 0.0C 0.96 2.39 Auxiliary Boiler Feed Building Organ 0.0(

0.00 0.09 0.09 0.00 P ip es Bo i

l e r Fee d

Bui d i n Sie c

r

_ _3 _ _

Auxiliary Boiler Feed Building Silencers 0.0~ 0.0~ 0.01 0.0~ 0.001 Table 3. ARCON96 flow and plume dimension data.

I UnDf~araePe Tnfnrmafinn I

Grade, feet 18 NorthAdijustment, 0 38.5611 Wind Speed Units 2

LowerMetlHe ght 10 Upper Met Height 60 Roughnes Length 0.1 Minimum Wid Is 0.5 Averaging Sector Width 4

Wind Direction Window. ° 9

Elevation Difference Table 4. ARCON96 miscellaneous data.

R-1 109298-01, Rev. 4 Page 8 of 26 2 February 2005

Results Table 5 shows the results of the ARCON96 analysis. The highest values of X/Q come from the auxiliary boiler feed building safety valve organ pipes, followed by releases from the side of the auxiliary boiler feed building, auxiliary boiler feed building atmospheric dump valve silencers, the containment vent, and the containment surface.

95% X/Q from ARCON96 0 to 2 2to8 8to24 I to 4 4 to 30 ID hours hours hours days days Containment Surface 3.57E-0 3.12E-04 1.24E-0 1.06E-04 7.99E-05 Containment Vent 6.OOE-04 5.20E-04 2.12E-0 1.76E-04 1.30E-04 Auxiliary Boiler Feed Building Side 9.86E-04 8.74E-04 4.50E-04 3.50E-04 2.80E-04 Auxiliary Boiler Feed Building Organ Pipes 1.14E-03 1.04E-03 5.05E-01 4.01E-04 3.211E-04 Auxiliary Boiler Feed Building Silencers 1.OOE-03 8.79E-0 4.41E-0 3.47E-0 2.78E-0 Table 5. Results of ARCON96 analysis.

References

1. Atmospheric Relative Concentrations in Building Wak-es, NUREG/CR-633 1 REV I, Pacific Northwest National Laboratory, Richland, WA, May 1997. (ARCON96 Manual)
2. Memorandum M-254060-01, April 5, 1999.
3. MET2ARCN Code Certification Package, CCP-Beth-04, April 11, 2000.
4. Memorandum M-254060-02, April 7, 2000.
5. Letter NEA-05-002, Floyd Gumble, Senior Lead Engineer, Entergy Nuclear Northwest to T. Edward Fenstermacher, ABS Consulting, January 20, 2005.
6. Containment Discharge Duct for Consolidated Edison Company Indian Point Generating Station Unit No. 3, U. E. & C. DrawingNo. 9321-F-13193.
7. Power Authority State of New York, Indian Point Unit No. 3 - Additional Facilities, Plot Plan Sheet 2, Drawing No. C004 Revision 8.
8. Yard Area - West of Containment Building Main Steam Piping Plan Sheet No. 1, Drawing No.

9321-F-20493 Rev. 17

9. Yard Area - West of Containment Building Main Steam Piping Sections and Elevations Sheet No. 2, Drawing No. 9321-F-20503 Rev. 15
10. Flow Off Muffler Additions Main Steam Dump Valve Vent Lines Sheet No. 1, A210148-1.
11. Miscellaneous Plant Areas & Buildings Ventilation Systems Plans, Sections and Details for Consolidated Edison Company Indian Point Generating Station Unit No. 3, U. E. & C. Drawing No.

9321-F-40433-5.

R-1 109298-01, Rev. 4 Page 9 of 26 2 February 2005

12. Drawing 9321 -F-14853 Rev. 3
13. Indian Point Unit No. 3 Nuclear Power Plant, Control Building (El 15'-00") Air Conditioning Equipment Room Plants & Sections, New York Power Authority Drawing 9321 -F-40173 Revision 11.
14. Profile Looking North Thru Intake Structure, Turbine, Prim. Aux. Bldgs. & Waste H. T. Pit for Consolidated Edison Company Indian Point Generating Station Unit No. 3, U. E. & C. Drawing No.

9321-F-15363.

R-1109298-O1, Rev. 4 Page 10 of 26 2 February 2005

ATTACHMENT 1. ARCON96 LOG FILES Printed copies of the log files from the four ARCON96 computer code runs follow.

R-1109298-01, Rev. 4 Page II of 26 2 February 2005

Program

Title:

ARCON96.

Developed For:

1 U.S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Division of Reactor Program Management Date:

June 25, 1997 NRC Contacts:

J. Y. Lee 11:00 a.m.

Phone: (301) 415 1080 e-mail: jyll~nrc.gov Phone: (301) 415 3167 e-mail: jjh~nrc.gov Phone: (301) 415 1232 e-mail: lab2@nrc.gov J. J. Hayes L. A Brown Code Developer:

J. V. Ramsdell Phone: (509) 372 6316 e-mail: j ramsdell~pnl.gov Code Documentation:

NUREG/CR-6331 Rev. 1 The program was prepared for an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, expressed or implied, or assumes any legal liability or responsibilities for any third party's use, or the results of such use, of any portion of this program or represents that its use by such third party would not infringe privately owned rights.

Program Run 2/ 2/2005 at 14:57:18

              • ARCON INPUT *********

Number of Meteorological Data Files =

3 Meteorological Data File Names C:\\IP3Prime\\IP 1995.MET C:\\IP3Prime\\IP 1996.MET C:\\IP3Prime\\IP_1997.MET Height of lower wind instrument (m) =

Height of upper wind instrument (m) =

Wind speeds entered as miles per hour 10.0 60.0 Ground-level release Release height (m)

Building Area (mA2)

=

40.3

=

3059.3 R-1 109298-01, Rev. 4 Page 12 of 26 2 February 2005

Effluent vertical velocity (m/s)

Vent or stack flow (m^3/s)

Vent or stack radius (m)

Direction..

intake to source (deg)

Wind direction sector width (deg)

Wind direction window (deg)

Distance to intake (m)

Intake height (m)

Terrain elevation difference (m)

Output file names ip3sOlrl.log ip3sOlrl.cfd Minimum Wind Speed (m/s)

Surface roughness length (m)

Sector averaging constant O

.00

=

.00

=

.00 038 90 353 -

083 65.0 2.3

.0

=

.5

=

.10

=

4.0 Initial value of sigma y Initial value of sigma z

=

7.32

=

13.31 Expanded output for code testing not selected Total Hours Hours Hours Hours Hours number of hours of data processed =

26304 of missing data

=

170 direction in window

=

8468 elevated plume w/ dir. in window =

0 of calm winds

=

361 direction not in window or calm

=

17305 DISTRIBUTION

SUMMARY

DATA BY AVERAGING INTERVAL AVER. PER.

UPPER LIM.

LOW LIM.

ABOVE RANGE IN RANGE BELOW RANGE ZERO TOTAL X/Qs

% NON ZERO 1

1.OOE-03 1.OOE-07 0.

8829.

0.

17305.

26134.

33.78 2

1.OOE-03 1.OOE-07 0.

10172.

0.

15946.

26118.

38.95 4

1.OOE-03 1.OOE-07 0.

11979.

0.

14109.

26088.

45.92 8

1.OOE-03 1.OOE-07 0.

14584.

0.

11444.

26028.

56.03 12 1.OOE-03 1.OOE-07 0.

16697.

0.

9351.

26048.

64.10 24 1.OOE-03 1.OOE-07 0.

20464.

0.

5547.

26011.

78.67 96 1.OOE-03 1.OOE-07 0.

25561.

0.

280.

25841.

98.92 168 1.OOE-03 1.OOE-07 0.

25549.

0.

46.

25595.

99.82 360 1.OOE-03 1.OOE-07 0.

25378.

0.

0.

25378.

100.00 720 1.OOE-03 1.OOE-07 0.

25002.

0.

0.

25002.

100.00 95th PERCENTILE X/Q VALUES 3.57E-04 3.54E-04 3.45E-04 3.23E-04 2.65E-04 1.90E-04 1.27E-04 1.07E-04 9.39E-05 8.61E-05 R-l 109298-01, Rev. 4 Page 13 of 26 2 February 2005

95% X/Q for standard averaging intervals 0 to 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> 2 to 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> 8 to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> 1 to 4 days 4 to 30 days 3.57E-04 3.12E-04 1.24E-04 1.06E-04 7.99E-05 HOURLY VALUE RANGE MAX X/Q 3.97E-04 2.49E-04 CENTERLINE SECTOR-AVERAGE MIN X/Q 3.53E-05 2.21E-05 NORMAL PROGRAM COMPLETION R-1 109298-01, Rev. 4 Page 14 of 26 2 February 2005

Program

Title:

ARCON96.

Developed For:

U.S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Division of Reactor Program Management Date:

June 25, 1997 NRC Contacts:

J. Y. Lee 11:00 a.m.

Phone: (301) 415 1080 e-mail: jyll@nrc.gov Phone: (301) 415 3167 e-mail: jjh~nrc.gov Phone: (301) 415 1232 e-mail: lab2@nrc.gov J. J. Hayes L. A Brown Code Developer:

J. V. Ramsdell Phone: (509) 372 6316 e-mail: j ramsdell~pnl.gov Code Documentation:

NUREG/CR-6331 Rev. 1 The program was prepared for an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, expressed or implied, or assumes any legal liability or responsibilities for any third party's use, or the results of such use, of any portion of this program or represents that its use by such third party would not infringe privately owned rights.

Program Run 2/ 2/2005 at 14:57:18

              • ARCON INPUT **********

Number of Meteorological Data Files =

3 Meteorological Data File Names C:\\IP3Prime\\IP 1995.MET C:\\IP3Prime\\IP 1996.MET C:\\IP3Prime\\IP_1997.MET Height of lower wind instrument (m) =

Height of upper wind instrument (m) =

Wind speeds entered as miles per hour 10.0 60.0 Ground-level release Release height (m)

Building Area (mA2) 76.2

=

3059.3 R-I 109298-01, Rev. 4 Page 15 of 26 2 February 2005

Effluent vertical velocity (mis)

Vent or stack flow (mA 3/s)

Vent or stack radius (m)

Direction..

intake to source (deg)

Wind direction sector width (deg)

Wind direction window (deg)

Distance to intake (m)

Intake height (m)

Terrain elevation difference (m)

Output file names ip3sO2rl.log ip3sO2rl.cfd Minimum Wind Speed (m/s)

Surface roughness length (m)

Sector averaging constant t

Initial value of sigma y Initial value of sigma z

=

.00

.00

=

.00 038 90 353 -

083 72.9 2.3

.0

=

.5

=

.10

=

4.0

=

.26

=

.00 Expanded output for code testing not selected Total Hours Hours Hours Hours Hours number of hours of data processed =

26304 of missing data

=

170 direction in window

=

8497 elevated plume w/ dir. in window =

0 of calm winds

=

293 direction not in window or calm

=

17344 DISTRIBUTION

SUMMARY

DATA BY AVERAGING INTERVAL AVER. PER.

UPPER LIM.

LOW LIM.

ABOVE RANGE IN RANGE BELOW RANGE ZERO TOTAL X/Qs

% NON ZERO 1

1.OOE-03 1.OOE-07 0.

8790.

0.

17344.

26134.

33.63 2

1.00E-03 1.OOE-07 0.

10124.

0.

15994.

26118.

38.76 4

1.OOE-03 1.OOE-07 0.

11924.

0.

14164.

26088.

45.71 8

1. OOE-03 1.OOE-07 0.

14514.

0.

11514.

26028.

55.76 12 1.OOE-03 1.OOE-07 0.

16620.

0.

9428.

26048.

63.81 24 1.OOE-03 1.OOE-07 0.

20376.

0.

5635.

26011.

78.34 96 1.OOE-03 1.00E-07 0.

25539.

0.

302.

25841.

98.83 168 1.OOE-03 1.OOE-07 0.

25549.

0.

46.

25595.

99.82 360 1.OOE-03

1. OOE-07 0.

25378.

0.

0.

25378.

100.00 720 1.OOE-03

1. OOE-07 0.

25002.

0.

0.

25002.

100.00 95th PERCENTILE X/Q VALUES 6.OOE-04 5.92E-04 5.72E-04 5.40E-04 4.48E-04 3.21E-04 2.12E-04 1.78E-04 1.54E-04 1.41E-04 R-l 109298-01, Rev. 4 Page 16 of 26 2 February 2005

95% X/Q for standard averaging intervals 0 to 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> 2 to 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> 8 to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> 1 to 4 days 4 to 30 days 6.OOE-04 5.20E-04 2.12E-04 1.76E-04

1. 30E-04 HOURLY VALUE RANGE MAX X/Q 7.74E-04 4.85E-04 CENTERLINE SECTOR-AVERAGE MIN X/Q 3.39E-05
2. 13E-05 NORMAL PROGRAM COMPLETION R-1 109298-01, Rev. 4 Page 17 of 26 2 February 2005

i Program

Title:

ARCON96.

Developed For:

U.S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Division of Reactor Program Management Date:

June 25, 1997 11:00 a.m.

NRC Contacts:

J. Y. Lee J. J. Hayes L. A Brown Phone: (301) 415 1080 e-mail: jyll~nrc.gov Phone: (301) 415 3167 e-mail: jjh@nrc.gov Phone: (301) 415 1232 e-mail: lab2@nrc.gov Code Developer:

J. V. Ramsdell Phone: (509) 372 6316 e-mail: j ramsdell~pnl.gov Code Documentation:

NUREG/CR-6331 Rev. 1 The program was prepared for an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, expressed or implied, or assumes any legal liability or responsibilities for any third party's use, or the results of such use, of any portion of this program or represents that its use by such third party would not infringe privately owned rights.

Program Run 2/ 2/2005 at 14:57:19

        • ARCON INPUT ********

Number of Meteorological Data Files =

3 Meteorological Data File Names C:\\IP3Prime\\IP 1995.MET C:\\IP3Prime\\IP 1996.MET C:\\IP3Prime\\IP_1997.MET Height of lower wind instrument (m)

Height of upper wind instrument (m)

Wind speeds entered as miles per hour 10.0 60.0 Ground-level release Release height (m)

Building Area (m^2)

=

14.8

=

3059.3 R-1 109298-01, Rev. 4 Page 18 of 26 2 February 2005

Effluent vertical velocity (m/s)

Vent or stack flow (mA3/s)

Vent or stack radius (m)

Direction..

intake to source (deg)

Wind direction sector width (deg)

Wind direction window (deg)

Distance to intake (m)

Intake height (m)

Terrain elevation difference (m)

Output file names ip3sO3rl.log ip3sO3rl.cfd Minimum Wind Speed (m/s)

Surface roughness length (m)

Sector averaging constant

=

.00

=

.00

. 00

=

021

=

90

=

336 - 066

=

66.5

=

2.3

=

.0

.5

=

.10

=

4.0 Initial value of sigma y Initial value of sigma z

=

.96 2.39 Expanded output for code testing not selected Total number of hours of data processed =

26304 Hours of missing data 170 Hours direction in window 10861 Hours elevated plume w/ dir. in window =

0 Hours of calm winds 284 Hours direction not in window or calm 14989 DISTRIBUTION AVER. PER.

UPPER LIM.

LOW LIM.

ABOVE RANGE IN RANGE BELOW RANGE ZERO TOTAL X/Qs

% NON ZERO

SUMMARY

DATA BY AVERAGING INTERVAL 1

1.00E-02 1.OOE-06 0.

11145.

0.

14989.

26134.

42.65 2

1.OOE-02 1.OOE-06 0.

12697.

0.

13421.

26118.

48.61 4

1.OOE-02 1.00E-06 0.

14733.

0.

11355.

26088.

56.47 8

1. OOE-02 1.OOE-06 0.

17551.

0.

8477.

26028.

67.43 12 1.OOE-02 1.OOE-06 0.

19624.

0.

6424.

26048.

75.34 24

1. OOE-02 1.00E-06 0.

22947.

0.

3064.

26011.

88.22 96 1.OOE-02 1.00E-06 0.

25829.

0.

12.

25841.

99.95 168 1.OOE-02 1.00E-06 0.

25595.

0.

0.

25595.

100.00 360

1. OOE-02
1. OOE-06 0.

25378.

0.

0.

25378.

100.00 720 1.OOE-02 1.00E-06 0.

25002.

0.

0.

25002.

100.00 95th PERCENTILE X/Q VALUES 9.86E-04 9.62E-04 9.38E-04 9.02E-04 7.75E-04 6.01E-04 4.12E-04 3.58E-04 3.23E-04 2.98E-04 R-1109298-0 1, Rev. 4 Page 19 of 26 2 February 2005

95% X/Q for standard averaging intervals 0 to 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> 2 to 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> 8 to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> 1 to 4 days 4 to 30 days 9.86E-04 8.74E-04 4.50E-04 3.50E-04 2.80E-04 HOURLY VALUE RANGE MAX X/Q 1.38E-03 8.62E-04 CENTERLINE SECTOR-AVERAGE MIN X/Q

1. 95E-04 1.22E-04 NORMAL PROGRAM COMPLETION R-1 109298-01, Rev. 4 Page 20 of 26 2 February 2005

Program

Title:

ARCON96.

Developed For:

U.S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Division of Reactor Program Management Date:

June 25, 1997 11:00 a.m.

NRC Contacts:

J. Y. Lee J. J. Hayes L. A Brown Code Developer: J. V. Ramsdell Phone: (301) 415 1080 e-mail: jyll~nrc.gov Phone: (301) 415 3167 e-mail: jjh@nrc.gov Phone: (301) 415 1232 e-mail: lab2@nrc.gov Phone: (509) 372 6316 e-mail: j ramsdell~pnl.gov Code Documentation: NUREG/CR-6331 Rev. 1 The program was prepared for an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, expressed or implied, or assumes any legal liability or responsibilities for any third party's use, or the results of such use, of any portion of this program or represents that its use by such third party would not infringe privately owned rights.

Program Run 2/ 2/2005 at 14:57:19

              • ARCON INPUT Number of Meteorological Data Files =

3 Meteorological Data File Names C:\\IP3Prime\\IP 1995.MET C:\\IP3Prime\\IP 1996.MET C:\\IP3Prime\\IP_1997.MET Height of lower wind instrument (m) =

Height of upper wind instrument (m) =

Wind speeds entered as miles per hour 10.0 60.0 Ground-level release Release height (m)

Building Area (mA2)

=

24.1 3059.3 R-1 109298-01, Rev. 4 Page 21 of 26 2 February 2005

Effluent vertical velocity (m/s)

Vent or stack flow (mA3/s)

Vent or stack radius (m)

Direction..

intake to source (deg)

Wind direction sector width (deg)

Wind direction window (deg)

Distance to intake (m)

Intake height (m)

Terrain elevation difference (m)

=

.00

=

.00

=

.00

=

018

=

90

=

333 - 063

=

68.9

=

2.3

=

.0 Output file names ip3sO4rl.log ip3sO4rl.cfd Minimum Wind Speed (m/s)

Surface roughness length (m)

Sector averaging constant

=

.5

=

.10

=

4.0 Initial value of sigma y Initial value of sigma z

.00

.00 Expanded output for code testing not selected Total number of hours of data processed -

26304 Hours of missing data 170 Hours direction in window

=

10871 Hours elevated plume w/ dir. in window =

0 Hours of calm winds

=

284 Hours direction not in window or calm

= 14979 DISTRIBUTION AVER. PER.

UPPER LIM.

LOW LIM.

ABOVE RANGE IN RANGE BELOW RANGE ZERO TOTAL X/Qs

% NON ZERO

SUMMARY

DATA BY AVERAGING INTERVAL 1

1.OOE-02 1.OOE-06 0.

11155.

0.

14979.

26134.

42.68 2

1.OOE-02 1.00E-06 0.

12764.

0.

13354.

26118.

48.87 4

1.00E-02 1.OOE-06 0.

14857.

0.

11231.

26088.

56.95 8

1.OOE-02 1.OOE-06 0.

17704.

0.

8324.

26028.

68.02 12 1.OOE-02 1.00E-06 0.

19764.

0.

6284.

26048.

75.88 24

1. OOE-02 1.OOE-06 0.

23061.

0.

2950.

26011.

88.66 96 1.OOE-02 1.OOE-06 0.

25829.

0.

12.

25841.

99.95 168 1.OOE-02 1.OOE-06 0.

25595.

0.

0.

25595.

100.00 360

1. OOE-02 1.OOE-06 0.

25378.

0.

0.

25378.

100.00 720 1.00E-02 1.OOE-06 0.

25002.

0.

0.

25002.

100.00 95th PERCENTILE X/Q VALUES 1.14E-03 l.11E-03 1.09E-03 1.06E-03 9.OOE-04 6.91E-04 4.73E-04 4.12E-04 3.69E-04 3.41E-04 R-l 109298-01, Rev. 4 Page 22 of 26 2 February 2005

95% X/Q for standard averaging intervals 0 to 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> 2 to 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> 8 to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> 1 to 4 days 4 to 30 days 1.14E-03

1. 04E-03 5.05E-04 4.01E-04 3.21E-04 HOURLY VALUE RANGE MAX X/Q 1.55E-03 9.74E-04 CENTERLINE SECTOR-AVERAGE MIN X/Q
1. 97E-04 1.24E-04 NORMAL PROGRAM COMPLETION R-1 109298-01, Rev. 4 Page 23 of 26 2 February 2005

Program

Title:

ARCON96.

Developed For:

U.S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Division of Reactor Program Management Date:

June 25, 1997 NRC Contacts:

J. Y. Lee 11:00 a.m.

Phone: (301) 415 1080 e-mail: jyll~nrc.gov Phone: (301) 415 3167 e-mail: jjh@nrc.gov Phone: (301) 415 1232 e-mail: lab2@nrc.gov J. J. Hayes L. A Brown Code Developer:

J. V. Ramsdell Phone: (509) 372 6316 e-mail: j ramsdell@pnl.gov Code Documentation:

NUREG/CR-6331 Rev. 1 The program was prepared for an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, expressed or implied, or assumes any legal liability or responsibilities for any third party's use, or the results of such use, of any portion of this program or represents that its use by such third party would not infringe privately owned rights.

Program Run 2/ 2/2005 at 14:57:19

              • ARCON INPUT
  • Number of Meteorological Data Files =

3 Meteorological Data File Names C:\\IP3Prime\\IP 1995.MET C:\\IP3Prime\\IP_1996.MET C:\\IP3Prime\\IP_1997.MET Height of lower wind instrument (m)

Height of upper wind instrument (m)

Wind speeds entered as miles per hour 10.0 60.0 Ground-level release Release height (m)

Building Area (mW2)

=

29.0 3059.3 R-1 109298-01, Rev. 4 Page 24 of 26 2 February 2005

Effluent vertical velocity (m/s)

Vent or stack flow (mA3/s)

Vent or stack radius (m)

Direction..

intake to source (deg)

Wind direction sector width (deg)

Wind direction window (deg)

Distance to intake (m)

Intake height (m)

Terrain elevation difference (m)

Output file names ip3sO5rl.log ip3sO5rl.cfd Minimum Wind Speed (m/s)

Surface roughness length (m)

Sector averaging constant

=

.00

=

.00

=

.00 018 90 333 -

063 73.8 2.3

.0

=

.5

=

.10

=

4.0 Initial value of sigma y Initial value of sigma z

.00

=

.00 Expanded output for code testing not selected Total number of hours of data processed =

26304 Hours of missing data

=

170 Hours direction in window

=

10871 Hours elevated plume w/ dir. in window =

0 Hours of calm winds

=

284 Hours direction not in window or calm

=

14979 DISTRIBUTION AVER. PER.

UPPER LIM.

LOW LIM.

ABOVE RANGE IN RANGE BELOW RANGE ZERO TOTAL X/Qs

% NON ZERO

SUMMARY

DATA BY AVERAGING INTERVAL 1

1.OOE-02 1.OOE-06 0.

11155.

0.

14979.

26134.

42.68 2

1.OOE-02 1.OOE-06 0.

12764.

0.

13354.

26118.

48.87 4

1.00E-02 1.OOE-06 0.

14857.

0.

11231.

26088.

56.95 8

1. OOE-02 1.OOE-06 0.

17704.

0.

8324.

26028.

68.02 12 1.OOE-02 1.OOE-06 0.

19764.

0.

6284.

26048.

75.88 24 1.OOE-02 1.OOE-06 0.

23061.

0.

2950.

26011.

88.66 96 1.OOE-02 1.OOE-06 0.

25829.

0.

12.

25841.

99.95 168 1.OOE-02 1.OOE-06 0.

25595.

0.

0.

25595.

100.00 360 1.OOE-02 1.00E-06 0.

25378.

0.

0.

25378.

100.00 720

1. OOE-02 1.00E-06 0.

25002.

0.

0.

25002.

100.00 95th PERCENTILE X/Q VALUES 1.00E-03 9.84E-04 9.60E-04 9.10E-04 7.80E-04 5.97E-04 4.09E-04 3.57E-04 3.19E-04 2.95E-04 R-1109298-0 1, Rev. 4 Page 25 of 26 2 February 2005

95% X/Q for standard averaging intervals 0 to 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> 2 to 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> 8 to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> 1 to 4 days 4 to 30 days 1.OOE-03 8.79E-04 4.41E-04 3.47E-04 2.78E-04 HOURLY VALUE RANGE MAX X/Q 1.33E-03 8.31E-04 CENTERLINE SECTOR-AVERAGE MIN X/Q 1.66E-04

1. 04E-04 NORMAL PROGRAM COMPLETION R-1109298-01, Rev. 4 Page 26 of 26 2 February 2005