ML050550032

From kanterella
Jump to navigation Jump to search
Special Report, Steam Generator Tube Plugging Report
ML050550032
Person / Time
Site: Saint Lucie 
Issue date: 02/11/2005
From: Jefferson W
Florida Power & Light Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
L-2005-030
Download: ML050550032 (1)


Text

FPL Florida Power& Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 February 11,2005 L-2005-030 10 CFR 50.36 10 CFR 50.4 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 Re:

St. Lucie Unit 2 Docket No. 50-389 Special Report Steam Generator Tube Plugging Report This letter is being sent pursuant to St. Lucie Unit 2 Technical Specification 4.4.5.5.a.

The number of tubes plugged in each steam generator during the Unit 2 refueling outage (SL2-15) is listed below.

Steam Generator 2A - 798 Steam Generator 2B - 837 Cumulative tubes plugged during this outage and previous outages:

Steam Generator 2A - 1469 Steam Generator 2B - 1709 Please contact us should you have any questions regarding this information.

William (/effers-Vice President St. Lucie Plant WJIspt

..' 

r ::

...1 o

an FPL Group company