ML050490312

From kanterella
Jump to navigation Jump to search
Request for Additional Information for the Review of the Donald C. Cook Nuclear Plant, Units 1 and 2, License Renewal Application
ML050490312
Person / Time
Site: Cook  
Issue date: 02/17/2005
From: Rowley J
NRC/NRR/DRIP/RLEP
To: Nazar M
Indiana Michigan Power Co
Rowley J, NRR/DRIP/RLEP, 415-4053
References
Download: ML050490312 (5)


Text

February 17, 2005 Mr. Mano K. Nazar Senior Vice President and Chief Nuclear Officer Indiana Michigan Power Company 500 Circle Drive Buchanan, MI 49107

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION (RAI) FOR THE REVIEW OF THE DONALD C. COOK NUCLEAR PLANT, UNITS 1 AND 2, LICENSE RENEWAL APPLICATION

Dear Mr. Nazar:

By letter dated October 31, 2003, Indiana Michigan Power Company, (I&M or the applicant) submitted an application pursuant to Title 10 of the Code of Federal Regulations Part 54 (10 CFR Part 54), to renew the operating licenses for Donald C. Cook Nuclear Plant (CNP),

Units 1 and 2, for review by the U.S. Nuclear Regulatory Commission (NRC). The NRC staff is reviewing the information contained in the license renewal application (LRA) and has identified, in the enclosure, an area where additional information is needed to complete the review.

This RAI was discussed with your staff, Richard Grumbir, and a mutually agreeable date for this response is within 30 days from the date of this letter. If you have any questions, please contact me at 301-415-4053 or e-mail JGR@nrc.gov.

Sincerely,

/RA/

Jonathan Rowley, Project Manager License Renewal Section A License Renewal and Environmental Impacts Program Division of Regulatory Improvement Programs Office of Nuclear Reactor Regulation Docket Nos. 50-315 and 50-316

Enclosure:

As stated cc w/encls: See next page

February 17, 2005 Mr. Mano K. Nazar Senior Vice President and Chief Nuclear Officer Indiana Michigan Power Company 500 Circle Drive Buchanan, MI 49107

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION (RAI) FOR THE REVIEW OF THE DONALD C. COOK NUCLEAR PLANT, UNITS 1 AND 2, LICENSE RENEWAL APPLICATION

Dear Mr. Nazar:

By letter dated October 31, 2003, Indiana Michigan Power Company, (I&M or the applicant) submitted an application pursuant to Title 10 of the Code of Federal Regulations Part 54 (10 CFR Part 54), to renew the operating licenses for Donald C. Cook Nuclear Plant (CNP), Units 1 and 2, for review by the U.S. Nuclear Regulatory Commission (NRC). The NRC staff is reviewing the information contained in the license renewal application (LRA) and has identified, in the enclosure, an area where additional information is needed to complete the review.

This RAI was discussed with your staff, Richard Grumbir, and a mutually agreeable date for this response is within 30 days from the date of this letter. If you have any questions, please contact me at 301-415-4053 or e-mail JGR@nrc.gov.

Sincerely,

/RA/

Jonathan Rowley, Project Manager License Renewal Section A License Renewal and Environmental Impacts Program Division of Regulatory Improvement Programs Office of Nuclear Reactor Regulation Docket Nos. 50-315 and 50-316

Enclosure:

As stated cc w/encls: See next page DISTRIBUTION: See next page Adams Accession No.: ML050490312 Document Name: E:\\Filenet\\ML050490312.wpd OFFICE PM:RLEP LA:RLEP SC:RLEP NAME JRowley YEdmonds SLee DATE 02/15 /05 02/ 15 /05 02/ 17 /05 OFFICIAL RECORD COPY

Donald C. Cook Nuclear Plant, Units 1 and 2 cc:

Regional Administrator, Region III U.S. Nuclear Regulatory Commission 2443 Warrenville Road, Suite 210 Lisle, IL 60532-4351 Township Supervisor Lake Township Hall P.O. Box 818 Bridgman, MI 49106 U.S. Nuclear Regulatory Commission Resident Inspectors Office 7700 Red Arrow Highway Stevensville, MI 49127 David W. Jenkins, Esquire Indiana Michigan Power Company One Cook Place Bridgman, MI 49106 Mayor, City of Bridgman P.O. Box 366 Bridgman, MI 49106 Special Assistant to the Governor Room 1 - State Capitol Lansing, MI 48909 Mr. John A. Zwolinski Director, Design Engineering and Regulatory Affairs Indiana Michigan Power Company Nuclear Generation Group 500 Circle Drive Buchanan, MI 49107 Patricia Lougheed 2443 Warrenville Rd.

Lisle, IL 60532 Michigan Department of Environmental Quality Waste and Hazardous Materials Div.

Hazardous Waste & Radiological Protection Section Nuclear Facilities Unit Constitution Hall, Lower-Level North 525 West Allegan Street P.O. Box 30241 Lansing, MI 48909-7741 Michael J. Finissi, Plant Manager Indiana Michigan Power Company Nuclear Generation Group One Cook Place Bridgman, MI 49106 Mr. Joseph N. Jensen, Site Vice President Indiana Michigan Power Company Nuclear Generation Group One Cook Place Bridgman, MI 49106 Mr. Fred Emerson Nuclear Energy Institute 1776 I Street, N.W., Suite 400 Washington, DC 20006-3708 Richard J. Grumbir Project Manager, License Renewal Indiana Michigan Power Company Nuclear Generation Group 500 Circle Drive Buchanan, MI 49107

DISTRIBUTION: Letter to: M. Nazar, Re: RAI for review of DC Cook Nuclear Plants, Units 1 and 2, Dated: February 17, 2005 Adams Accession No.: ML050490312 HARD COPY RLEP RF E-MAIL:

RidsNrrDrip RidsNrrDe G. Bagchi K. Manoly W. Bateman J. Calvo R. Jenkins P. Shemanski J. Fair RidsNrrDssa RidsNrrDipm D. Thatcher R. Pettis G. Galletti C. Li K. Winsberg (RidsOgcMailCenter)

R. Weisman M. Mayfield A. Murphy S. Smith (srs3)

S. Duraiswamy Y. L. (Renee) Li RLEP Staff G. Galletti L. Lund S. Coffin T. Chan J. Minns R. Gramm A. Howell M. Shuaibi J. Strasma, RIV M. Kotzalas OPA NRR/ADPT secretary (RidsNrrAdpt)

Enclosure DONALD C. COOK NUCLEAR PLANT, UNITS 1 AND 2 LICENSE RENEWAL APPLICATION (LRA)

REQUEST FOR ADDITIONAL INFORMATION (RAI)

RAI B.1.29-1 Regarding detecting aging effects for selective leaching, GALL XI.M33, SELECTIVE LEACHING OF MATERIALS, states:

Detection of Aging Effects: The one-time visual inspection and hardness measurement includes close examination of a select set of components to determine whether selective leaching has occurred and whether the resulting loss of strength and/or material will affect the intended functions of these components during the period of extended operation. Selective leaching generally does not cause changes in dimensions and is difficult to detect. One acceptable procedure is to visually inspect the susceptible components closely and conduct Brinell Hardness testing on the inside surfaces of the selected set of components to determine if selective leaching has occurred. If it is occurring, an engineering evaluation is initiated to determine acceptability of the affected components for further service.

In your commitment regarding the method you will use for selective leaching you stated:

The Service Water System Reliability Program will be enhanced to check for selective leaching during visual inspections.

To be consistent with GALL, hardness testing or other acceptable physical test is required.

Your commitment does not indicate that the checking you do during visual inspections will include hardness testing or equivalent physical testing as required by GALL.

Please clearly state if hardness testing, or an acceptable equivalent test, will be part of your program. If not, identify, for NRC staff evaluation, the exception you are taking to GALL and the basis for that exception.