PAM Instrumentation 3.3.3.1 ACTIONS (continued)
CONDITION REQUIRED ACTION COMPLETION TIME C. One or more Functions C.1 Restore one required 7 days with two required channel to OPERABLE channels inoperable.
status.
D. (Deleted).
E. Required Action and E.1 Enter the Condition Immediately associated Completion referenced in Time of Condition C not Table 3.3.3.1-1 for the met.
channel.
F. As required by Required F.1 Be in MODE 3.
12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> Action E.1 and referenced in Table 3.3.3.1-1.
G. As required by Required G.1 Initiate action in Immediately Action E.1 and referenced accordance with in Table 3.3.3.1-1.
Specification 5.6.6.
I BFN-UNIT 1 3.3-24 Amendment No. 2Z4-i 253
PAM Instrumentation 3.3.3.1 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.3.3.1.1 Perform CHANNEL CHECK for each required 31 days PAM instrumentation channel.
SR 3.3.3.1.2 (Deleted).
SR 3.3.3.1.3 Perform CHANNEL CALIBRATION of the 184 days Reactor Pressure Functions.
SR 3.3.3.1.4 Perform CHANNEL CALIBRATION for each 18 months required PAM instrumentation channel except for the Reactor Pressure Function.
I BFN-UNIT 1 3.3-25 Amendment No. 234, 253
PAM Instrumentation 3.3.3.1 Table 3.3.3.1-1 (page 1 of 1)
Post Accident Monitoring Instrumentation CONDITIONS REQUIRED REFERENCED FUNCTION CHANNELS FROM REQUIRED ACTION E.1
- 1. Reactor Pressure 2
F
- a. Emergency Systems Range 2
F
- b. Post-Accident Flood Range 2
F
- 3. Suppression Pool Water Level 2
F
- 4. Drywell Pressure
- a. Normal Range 2
F
- b. Wide Range 2
F
- 5. Primary Containment Area Radiation 2
G
- 6.
PCIV Position 2 per penetration flow path('")
F
- 7. (Deleted)
- 8. Suppression Pool Water Temperature 2
F
- 9. Drywell Atmosphere Temperature 2
F I
(a) Not required for isolation valves whose associated penetration flow path Is Isolated by at least one dosed and deactivated automatc valve, dosed manual valve, blind flange, or check valve Wvth flow through the valve secured.
(b) Only one position indication channel Is required for penetration flow paths with only one installed control room PAM category 1 indication channel.
BFN-UNIT 1 3.3-26 Amendment No. 234, 253
PAM Instrumentation 3.3.3.1 ACTIONS (continued)
CONDITION REQUIRED ACTION COMPLETION TIME C. One or more Functions C.1 Restore one required 7 days with two required channel to OPERABLE channels inoperable.
status.
D. (Deleted).
E. Required Action and E.1 Enter the Condition Immediately associated Completion referenced in Time of Condition C not Table 3.3.3.1-1 for the met.
channel.
F. As required by Required F.1 Be in MODE 3.
12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> Action E.1 and referenced in Table 3.3.3.1-1.
G. As required by Required G.1 Initiate action in Immediately Action E.1 and referenced accordance with in Table 3.3.3.1-1.
Specification 5.6.6.
I I
BFN-UNIT 2 3.3-25 Amendment No. 253 292
PAM Instrumentation 3.3.3.1 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.3.3.1.1 Perform CHANNEL CHECK for each required 31 days PAM instrumentation channel.
SR 3.3.3.1.2 (Deleted)
SR 3.3.3.1.3 Perform CHANNEL CALIBRATION of the 184 days Reactor Pressure Functions.
SR 3.3.3.1.4 Perform CHANNEL CALIBRATION for each 24 months required PAM instrumentation channel except for the Reactor Pressure Function.
I BFN-UNIT 2 3.3-26 Amendment No. 255, 292
PAM Instrumentation 3.3.3.1 Table 3.3.3.1-1 (page 1 of 1)
Post Accident Monitoring Instrumentation REQUIRED CHANNELS FUNCTION CONDITIONS REFERENCED FROM REQUIRED ACTION E.1 F
- 1. Reactor Pressure
- a. Emergency Systems Range
- b. Post-Accident Flood Range
- 3. Suppression Pool Water Level
- 4. Drywell Pressure
- a. Normal Range
- b. Wide Range
- 5. Primary Containment Area Radiation
- 6. PCIV Position
- 7. (Deleted)
- 8. Suppression Pool Water Temperature
- 9. Drywell Atmosphere Temperature 2
2 2
2 2
2 2
2 per penetration flow path~ab) 2 2
F F
F F
F G
F I
F F
(a) Not required for Isolation valves whose associated penetration flow path Is Isolated by at least one dosed and deactivated automatic valve, closed manual valve, blind flange, or check valve with flow through the valve secured.
(b) Only one position indication channel Is required for penetration flow paths with only one installed control room PAM category 1 Indication channel.
BFN-UNIT 2 3.3-27 Amendment No. 253 292
PAM Instrumentation 3.3.3.1 ACTIONS (continued)
CONDITION REQUIRED ACTION COMPLETION TIME C. One or more Functions C.1 Restore one required 7 days with two required channel to OPERABLE channels inoperable.
status.
D. (Deleted).
E. Required Action and E.1 Enter the Condition Immediately associated Completion referenced in Time of Condition C not Table 3.3.3.1-1 for the met.
channel.
F. As required by Required F.1 Be in MODE 3.
12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> Action E.1 and referenced in Table 3.3.3.1-1.
G. As required by Required G.1 Initiate action in Immediately Action E.1 and referenced accordance with in Table 3.3.3.1-1.
Specification 5.6.6.
I I
BFN-UNIT 3 3.3-25 Amendment No. 243, 251
PAM Instrumentation 3.3.3.1 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.3.3.1.1 Perform CHANNEL CHECK for each required 31 days PAM instrumentation channel.
SR 3.3.3.1.2 (Deleted)
SR 3.3.3.1.3 Perform CHANNEL CALIBRATION of the 184 days Reactor Pressure Functions.
SR 3.3.3.1.4 Perform CHANNEL CALIBRATION for each 24 months required PAM instrumentation channel except for the Reactor Pressure Function.
BFN-UNIT 3 3.3-26 Amendment No. 245, 251
PAM Instrumentation 3.3.3.1 Table 3.3.3.1-1 (page 1 of 1)
Post Acddent Monitoring Instrumentation REQUIRED CHANNELS FUNCTION CONDITIONS REFERENCED FROM REQUIRED ACTION E.1 F
- 1. Reactor Pressure
- a. Emergency Systems Range
- b. Post-Accident Flood Range
- 3. Suppression Pool Water Level
- 4. Drywell Pressure
- a. Normal Range
- b. Wide Range
- 5.
Primary Containment Area Radiation
- 6. PCIV Position
- 7. (Deleted)
- 8. Suppression Pool Water Temperature
- 9. Drywell Atmosphere Temperature 2
2 2
2 2
2 2
2 per penetration flow path(a)(b) 2 2
F F
F F
F G
F I
F F
(a) Not required for Isolation valves whose associated penetration flow path Is isolated by at least one dosed and deactivated automatic valve, dosed manual valve, blind flange, or check valve with now through the valve secured.
(b) Only one position Indication channel is required for penetration flow paths with only one installed control room PAM category 1 indication channel.
BFN-UNIT 3 3.3-27 Amendment No. 243 251