ML050420302

From kanterella
Jump to navigation Jump to search
Report of Tritium Sample
ML050420302
Person / Time
Site: Watts Bar  Tennessee Valley Authority icon.png
Issue date: 02/11/2005
From: Cahill S
Reactor Projects Region 2 Branch 6
To:
Tennessee Valley Authority
References
MR 2-05-0004
Download: ML050420302 (1)


Text

Morning Report Date: FEB 11, 2005 PRIORITY ATTENTION REQUIRED MORNING REPORT - REGION II Licensee/Facility:

Notification:

2-2005-0004 02/11/2005 MR Number:

TENNESSEE VALLEY AUTHORITY

[1] W-4-LP, [2] W-4-LP Date:

Watts Bar Call / Fax from Licensee Spring City, Tennessee 050-00390 050-00391 Dockets:

Watts Bar Report of Tritium Sample

Subject:

This is an update to the 10 CFR 50.72 notification (EN 41400) dated February 10, 2005, regarding the offsite notification due to exceeding the offsite dose calculation manual (ODCM) reporting level for tritium concentration (30,000 picocuries per liter) at Watts Bar. The licensee is currently using a 4-inch temporary piping system as a temporary radwaste line while the permanent radwaste piping is being replaced. Preliminary investigation found a small leak from a coupling in the temporary radwaste line. This leak likely contributed to the elevated tritium level in the onsite well.

The coupling leak in the temporary line has been repaired. Since the repairs were made, tritium levels in the affected monitoring well have decreased. Licensee personnel continue to sample nearby monitoring wells to determine the extent of the tritium and to search for other potential sources of leakage.

Regional Action: The resident inspectors observed the temporary line repairs and continue to monitor the licensee's actions and investigation of the event. The resident inspectors, with assistance from Region II Radiological Protection Inspectors, have been closely monitoring the licensee's actions to monitor groundwater. These licensee actions were taken due to previous problems that caused the licensee to initiate replacement of the permanent underground radwaste piping. Region II plans to continue to inspect the licensee's activities and corrective actions.

Discussion:

Contact:

Email:

Phone No:

Org:

CAHILL, STEPHEN J SJC2@nrc.gov (404) 562-4520 R2