February 7, 2005 Mr. Karl W. Singer Chief Nuclear Officer and Executive Vice President Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801
SUBJECT:
SEQUOYAH NUCLEAR PLANT, UNITS 1 AND 2 WITHDRAWAL OF REQUEST FOR ADDITIONAL INFORMATION REGARDING RESPONSE TO BULLETIN 2004-01 (TAC NOS. MC3512 AND MC3513)
Dear Mr. Singer:
By letter dated November 10, 2004, the U.S. Nuclear Regulatory Commission (NRC) staff issued a request for additional information regarding your response to NRC Bulletin 2004-01, Inspection of Alloy 82/182/600 Materials Used in the Fabrication of Pressurizer Penetrations and Steam Space Piping Connections at Pressurized-Water Reactors. Our letter requested that you supplement your Bulletin response by agreeing to notify NRC headquarters staff if, in the future, you obtain inspection results indicating that circumferential primary water stress corrosion cracking has occurred at any location covered under the scope of Bulletin 2004-01.
The staff has subsequently concluded that the request for additional information solicits an additional reporting requirement and commitment from the licensee. Since this action is inconsistent with our internal processes, we hereby withdraw the subject request for additional information.
We apologize for any inconvenience this may have caused.
Sincerely,
/RA/
Douglas V. PIckett, Senior Project Manager, Section 2 Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-327 and 50-328 cc: See next page
February 7, 2005 Mr. Karl W. Singer Chief Nuclear Officer and Executive Vice President Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801
SUBJECT:
SEQUOYAH NUCLEAR PLANT, UNITS 1 AND 2 WITHDRAWAL OF REQUEST FOR ADDITIONAL INFORMATION REGARDING RESPONSE TO BULLETIN 2004-01 (TAC NOS. MC3512 AND MC3513)
Dear Mr. Singer:
By letter dated November 10, 2004, the U.S. Nuclear Regulatory Commission (NRC) staff issued a request for additional information regarding your response to NRC Bulletin 2004-01, Inspection of Alloy 82/182/600 Materials Used in the Fabrication of Pressurizer Penetrations and Steam Space Piping Connections at Pressurized-Water Reactors. Our letter requested that you supplement your Bulletin response by agreeing to notify NRC headquarters staff if, in the future, you obtain inspection results indicating that circumferential primary water stress corrosion cracking has occurred at any location covered under the scope of Bulletin 2004-01.
The staff has subsequently concluded that the request for additional information solicits an additional reporting requirement and commitment from the licensee. Since this action is inconsistent with our internal processes, we hereby withdraw the subject request for additional information.
We apologize for any inconvenience this may have caused.
Sincerely,
/RA/
Douglas V. PIckett, Senior Project Manager, Section 2 Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-327 and 50-328 cc: See next page DISTRIBUTION:
PUBLIC PDII-2 r/f OGC DPickett ACRS DLPM DPR MMarshall BClayton SCahill, R2 TColburn MMitchell JShea ADAMS ACCESSION NO.: ML050330262 NRR-088 OFFICE PM:LPD2-2 LA:LPD2-2 SC:LPD2-2 NAME DPickett BClayton MMarshall DATE 02 / 3 / 05 02 / 2 / 05 02 / 7 / 05 OFFICIAL RECORD COPY
Mr. Karl W. Singer SEQUOYAH NUCLEAR PLANT Tennessee Valley Authority cc:
Mr. Ashok S. Bhatnagar, Senior Vice President Nuclear Operations Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. Larry S. Bryant, General Manager Nuclear Engineering Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. Randy Douet Site Vice President Sequoyah Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Soddy Daisy, TN 37384-2000 General Counsel Tennessee Valley Authority ET 11A 400 West Summit Hill Drive Knoxville, TN 37902 Mr. John C. Fornicola, Manager Nuclear Assurance and Licensing Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. Fredrick C. Mashburn Senior Program Manager Nuclear Licensing Tennessee Valley Authority 4X Blue Ridge 1101 Market Street Chattanooga, TN 37402-2801 Mr. Paul L. Pace, Manager Licensing and Industry Affairs ATTN: James D. Smith Sequoyah Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Soddy Daisy, TN 37384-2000 Mr. David A. Kulisek, Plant Manager Sequoyah Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Soddy Daisy, TN 37384-2000 Senior Resident Inspector Sequoyah Nuclear Plant U.S. Nuclear Regulatory Commission 2600 Igou Ferry Road Soddy Daisy, TN 37379 Mr. Lawrence E. Nanney, Director Division of Radiological Health Dept. of Environment & Conservation Third Floor, L and C Annex 401 Church Street Nashville, TN 37243-1532 County Mayor Hamilton County Courthouse Chattanooga, TN 37402-2801 Ms. Ann P. Harris 341 Swing Loop Road Rockwood, Tennessee 37854