January 19, 2005 LICENSEE:
Nuclear Management Company, LLC FACILITY:
Point Beach Nuclear Plant, Units 1 and 2
SUBJECT:
SUMMARY
OF TELEPHONE CONFERENCE HELD ON JANUARY 05, 2005, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND NUCLEAR MANAGEMENT COMPANY, LLC, CONCERNING REQUESTS FOR ADDITIONAL INFORMATION PERTAINING TO THE POINT BEACH NUCLEAR PLANT, UNITS 1 AND 2, LICENSE RENEWAL APPLICATION The U.S. Nuclear Regulatory Commission staff (the staff) and representatives of Nuclear Management Company, LLC (NMC) held a telephone conference on January 05, 2005, to discuss and clarify the staffs requests for additional information (RAIs) concerning the Point Beach Nuclear Plant, Units 1 and 2, license renewal application. The conference call was useful in clarifying the intent of the staffs RAIs. provides a listing of the meeting participants. Enclosure 2 contains a listing of the RAIs discussed with the applicant, including a brief description on the status of the items. contains draft responses provided by the applicant.
The applicant had an opportunity to comment on this summary.
/RA/
Verónica M. Rodríguez, Project Manager License Renewal Section A License Renewal and Environmental Impacts Program Division of Regulatory Improvement Programs Office of Nuclear Reactor Regulation Docket Nos. 50-266 and 50-301
Enclosures:
As stated cc w/encls: See next page
ML050260585 DOCUMENT NAME: E:\\Filenet\\ML050260585.wpd OFFICE PM:RLEP SC:RLEP NAME VRodríguez Slee DATE 1/19/05 1/19/05
Point Beach Nuclear Plant, Units 1 and 2 cc:
Jonathan Rogoff, Esq.
Vice President, Counsel & Secretary Nuclear Management Company, LLC 700 First Street Hudson, WI 54016 Mr. Frederick D. Kuester President and Chief Executive Officer We Generation 231 West Michigan Street Milwaukee, WI 53201 James Connolly Manager, Regulatory Affairs Point Beach Nuclear Plant Nuclear Management Company, LLC 6610 Nuclear Road Two Rivers, WI 54241 Mr. Ken Duveneck Town Chairman Town of Two Creeks 13017 State Highway 42 Mishicot, WI 54228 Chairman Public Service Commission of Wisconsin P.O. Box 7854 Madison, WI 53707-7854 Regional Administrator, Region III U.S. Nuclear Regulatory Commission 801 Warrenville Road Lisle, IL 60532-4351 Resident Inspector's Office U.S. Nuclear Regulatory Commission 6612 Nuclear Road Two Rivers, WI 54241 Mr. Jeffrey Kitsembel Electric Division Public Service Commission of Wisconsin P.O. Box 7854 Madison, WI 53707-7854 David Weaver Nuclear Asset Manager Wisconsin Electric Power Company 231 West Michigan Street Milwaukee, WI 53201 John Paul Cowan Executive Vice President & Chief Nuclear Officer Nuclear Management Company, LLC 700 First Street Hudson, WI 54016 Douglas E. Cooper Senior Vice President - Group Operations Palisades Nuclear Plant Nuclear Management Company, LLC 27780 Blue Star Memorial Highway Covert, MI 49043 Fred Emerson Nuclear Energy Institute 1776 I Street, NW., Suite 400 Washington, DC 20006-3708 Roger A. Newton 3623 Nagawicka Shores Drive Hartland, WI 53029 James E. Knorr License Renewal Project Nuclear Management Company, LLC 6610 Nuclear Road Point Beach Nuclear Plant Two Rivers, WI 54241
DISTRIBUTION: Note to Licensee: NMC, LLC, Pt. Beach Nuclear Plant, Units 1 and 2,
Subject:
Summary of Telephone Conference Held on January 05, 2005 ML050260585 HARD COPY RLEP RF E-MAIL:
RidsNrrDrip RidsNrrDe G. Bagchi K. Manoly W. Bateman J. Calvo R. Jenkins P. Shemanski J. Fair RidsNrrDssa RidsNrrDipm D. Thatcher R. Pettis G. Galletti C. Li M. Itzkowitz (RidsOgcMailCenter)
R. Weisman M. Mayfield A. Murphy S. Smith (srs3)
S. Duraiswamy Y. L. (Renee) Li RLEP Staff P. Lougheed, RIII J. Strasma, RIII A. Stone, RIII H. Chernoff W. Ruland C. Marco L. Raghavan T. Mensah OPA LIST OF PARTICIPANTS FOR TELEPHONE CONFERENCE TO DISCUSS THE POINT BEACH NUCLEAR PLANT, UNITS 1 AND 2 LICENSE RENEWAL APPLICATION JANUARY 5, 2005 Participants Affiliations J. Knorr Nuclear Management Company, LLC M. Morgan Nuclear Regulatory Commission G. Suber Nuclear Regulatory Commission V. Rodriguez Nuclear Regulatory Commission DRAFT REQUESTS FOR ADDITIONAL INFORMATION (RAI)
POINT BEACH NUCLEAR PLANT, UNITS 1 AND 2 LICENSE RENEWAL APPLICATION January 5, 2005 The U.S. Nuclear Regulatory Commission staff (the staff) and representatives of Nuclear Management Company, LLC (NMC) held a telephone conference call on January 05, 2005, to discuss and clarify the staffs requests for additional information (RAIs) concerning the Point Beach Nuclear Plant, Units 1 and 2, license renewal application (LRA). The following RAIs were discussed during the telephone conference call.
Section 2.3.3 Auxiliary Systems 2.3.3.4 Waste Disposal System RAIs RAI 2.3.3.4-1 The PBNP UFSAR states that the Waste Disposal (WD) System discharge to the Service Water System has an automatic isolation function to prevent exceeding 10 CFR 20 and 100 limits due to high effluent radioactivity. The PBNP LRA Section 2.3.3.4 states that piping and valves credited for service water isolation from WD System components are in-scope.
However, the drain isolation valve WL-1785A and its inter-tie piping to the WD System are shown as not in-scope on license renewal drawing LR-684J971, Sheet 2, Unit 1 & 2 (Waste &
Blowdown Evaporator Distillate Process System), at location A-9. Failure of WL-1785A valve and its associated piping could cause a loss of this 10 CFR 20 and 10 CFR 100 required function. Justify your determination to exclude the WL-1785A valve and its associated piping from the scope of license renewal.
Discussion: The applicant clarified their draft response. The applicant will provide their formal response in writing.
RAI 2.3.3.4-2 The PBNP UFSAR states WD system discharge to the Service Water System has an automatic isolation function to prevent exceeding 10 CFR 20 and 100 limits due to high effluent radioactivity. The PBNP LRA Section 2.3.3.4 states that piping and valves credited for Service Water System isolation from WD components are in-scope. However, the license renewal application drawing LR-PBM-231, Sheet 1, Unit 1&2 De-ionized and Reactor Water Makeup Water at location F-7, indicates that valve RWM1249A and its downstream piping is not in-scope. Failure of RWM1249A and its downstream piping could cause a loss of the 10 CFR 20 and 10 CFR 100 required function. Justify your determination to exclude the RWM1249A valve and its downstream piping from the scope of license renewal.
Discussion: The applicant clarified their draft response. The applicant will provide their formal response in writing.
RAI 2.3.3.4-3 The PBNP LRA Section 2.3.3.4 states that principal components of the WD System within the scope of License Renewal include the heat exchangers with Component Cooling Water interfaces and the piping and valves that are credited for Service Water System isolation from WD System components. Drawing LR-684J971, Sheet 1 Unit 1-2, at location C-3 indicates that the following components are out-of-scope: the service water supply to HX-702 (Boric Acid Waste Evaporator Vacuum system Heat Exchanger), the interface with the HX, and the interface isolation valve BS-VA37. This is contrary to the information provided in the LRA and drawing LR-M-2207 sheet 1, Unit 2 service water at location A-9, which indicate these components are in-scope. There are also a number of WD/SW interface components on Drawing LR-684J971, Sheet 1 that are not shown do not appear on LR-M-2207, Sheet 1 and may need to be in-scope. Failure of these components could adversely impact the isolation functions between the WD System and other interfacing systems. Provide additional information and justify your determination for not considering these components to be in-scope for license renewal.
Discussion: The applicant clarified their draft response. The applicant will provide their formal response in writing.
RAI 2.3.3.4-4 There are quite a few inconsistencies within the Waste Disposal system designations shown on the license renewal drawings which are identified as follows:
- a. The print-to-print inter-tie designator from LR-684J971, Sheet 2 Unit 1-2, Waste and Blowdown Evaporator Distillate Process system at location A-8 to the Service Water Overboard piping M-207 sheet 3 is not designated as in-scope.
- b. LR-684J971, sheet 2 Unit 1-2, Waste and Blowdown Evaporator Distillate Process system at location C-8 indicates the piping upstream of RWM1249A as in-scope. This is not consistent with drawing LR-PBM-231 sheet 1 Unit 1&2 De-ionized and Reactor Water Makeup Water.
c.
LR684J971, sheet 1 Unit 1-2, Waste Disposal system at location C-9 indicates the piping segment upstream of piping segment WD-151R-15 at location E-9 and downstream of isolation valve 1708 to be in-scope. There appears to be no LRA basis for this determination.
Failure of the above components currently designated as out-of-scope could have an adverse impact on the intended functions of the Waste Disposal System. Provide additional information to clarify your determinations as to which Waste Disposal System components, as described above, are in-scope for license renewal.
Discussion: The applicant clarified their draft response. The applicant will provide their formal response in writing.
2.3.3.8 Emergency Power - Support Systems for Emergency Diesels RAIs RAI 2.3.3.8 - 1 The PBNP UFSAR Section 8.8 states that the Diesel Generator (DG) system has several auxiliary support systems that must function in order to perform its safety related function including the air intake and exhaust system. License renewal drawing LR-M-226 shows the air intake oil bath filters inside the DG building with air intake screens shown on the building wall.
The air intake screens on the DG building walls are shown as out-of-scope of license renewal on license renewal drawing LR-M-226, Sheets 1 and 2 at location E-3. LRA Section 2.4.4 states that the DG building is a safety-related Seismic Class I structure but does not specifically address the air intake screens. Provide additional information and justify your determination to not include the diesel generator air intake screens in-scope for license renewal and subject to an AMR.
Discussion: The applicant clarified their draft response. The applicant will provide their formal response in writing.
RAI 2.3.3.8 - 2 The PBNP UFSAR Section 8.8 states that the Diesel Generator (DG) system has several auxiliary support systems that must function in order to perform its safety related function including the fuel oil system. The instrument CS P105 and associated line on the gas turbine fuel oil supply pump P-105 is shown as out-of-scope of license renewal on license renewal drawing LR-M-219, Sheet 1 at location B-9. This is inconsistent with instruments CS P70A and CS P70B for fuel oil transfer pumps P-70A and P-70B which shows these instruments and their associated lines as in-scope. Failure of this instrument and its associated line may adversely impact the integrity of the gas turbine fuel oil transfer pump. A degraded gas turbine fuel oil transfer pump could adversely impact the station blackout function of the gas turbine generator.
Provide additional information to support your determination that it is acceptable to not include the instrument CS P105 and its associated line as in-scope for license renewal.
Discussion: The applicant clarified their draft response. The applicant will provide their formal response in writing.
RAI 2.3.3.8 - 3 The PBNP UFSAR Section 8.8 states that the Diesel Generator (DG) system has several auxiliary support systems that must function in order to perform its safety related function including the fuel oil system. The instruments POS 3930 and CS 3930 and their associated lines on the DG day tank T-31A are shown as out-of-scope of license renewal on license renewal drawing LR-M-219, Sheet 1 at location G-3. This is inconsistent with instruments POS 3931 and CS 3931 for DG day tank T-31B which shows these instruments and their associated lines as in-scope. Failure of these instruments and their associated lines may adversely impact the integrity of the supply lines to the DG day tank. A degraded DG day tank supply could adversely impact the safety-related function of the G01 diesel generator. Provide additional information to support your determination that it is acceptable to not include the instruments POS 3930 and CS 3930 and their associated lines as in-scope for license renewal.
Discussion: The applicant clarified their draft response. The applicant will provide their formal response in writing.
RAI 2.3.3.8 - 4 The PBNP UFSAR Section 8.8 states that the Diesel Generator (DG) system has several auxiliary support systems that must function in order to perform its safety related function including the fuel oil system. The solenoid vent valve FO 3922 S on flow control valve FC 3922 is shown as in-scope for license renewal on license renewal drawing LR-M-219, Sheet 1 at location G-4. The line to this solenoid vent valve is shown as out-of-scope for license renewal.
In addition, the solenoid vent valve FO 3923 S on flow control valve FC 3923 is shown as out-of-scope at location E-9. A degraded DG fuel oil supply system could adversely impact the safety-related function of the diesel generators. Provide additional information to clarify why only solenoid vent valve FO 3922 S on FC 3922 is shown as in-scope, while the associated lines and the similar vent valve configuration on FC 3923 are not shown in-scope for license renewal.
Discussion: The applicant clarified their draft response. The applicant will provide their formal response in writing.
RAI 2.3.3.8 - 5 The PBNP UFSAR Section 8.8 states that the Diesel Generator (DG) system has several auxiliary support systems that must function in order to perform its safety related function including the fuel oil system. The 20 man way, SAX 7907, 3 inch vent lines and LS 3942 on the emergency fuel tank T-72 are shown as out-of-scope for license renewal on license renewal drawing LR-M-219, Sheet 1 at location C-5. This is inconsistent with the 24 man way, SAX 7913A, 4 inch vent lines and LS 3933A for DG storage tank T-175A shown on license renewal drawing LR-M-219, Sheet 2 which shows similar equipment on T-175A as in-scope. A degraded DG emergency fuel tank T-72 could adversely impact the emergency fuel supply and the safety-related function of the diesel generators. Provide additional information to support your determination that the 20" man way, SAX 7907, 3 inch vent lines and LS 3942 on the emergency fuel tank are out-of-scope for license renewal.
Discussion: The applicant clarified their draft response. The applicant will provide their formal response in writing.
2.3.3.14 Plant Sampling System RAIs No RAIs are identified for the scoping and screening review for the Plant Sampling system for the PBNP LRA.
2.3.3.15 Plant Air System RAIs RAI 2.3.3.15 - 1 The PBNP UFSAR Section 9.7.1 states, ?The IA [Instrument Air] system shall automatically isolate the purge supply and exhaust valve accumulators, including the supplemental nitrogen bottle system for 2VNPSE-3212 and 2VNPSE-3244, from the IA system during a loss of instrument air to maintain containment integrity and prevent release of radioactivity to the
outside environment. Drawing LR-PBM-2332 shows two valve actuators (listed below) as out-of-scope for license renewal. LRA Section 2.3.3.15 states that the valve bodies are in-scope as a pressure boundary. The two valve actuators are not shown on plant drawings in a manner that is consistent with other similar valves in the IA system. If portions of these valves have pressure boundary functions that are not in-scope, their failure could adversely impact the IA system pressure boundary function. Provide clarification and justification as to why the following valve actuators are not shown as in-scope for license renewal and subject to an AMR.
- a. LR-PBM-2332 - Actuator for 2VNPSE-3212, location E-2.
- b. LR-PBM-2332 - Actuator for 2VNPSE-3244, location E-6.
Discussion: The applicant clarified their draft response. The applicant will provide their formal response in writing.
RAI 2.3.3.15 - 2 The PBNP UFSAR Section 9.7.1 states, ?The IA system shall automatically isolate the instrument air lines penetrating containment whenever a containment isolation signal exists to maintain containment integrity and prevent release of radioactivity to the outside environment.
Drawing LR-M-209, Sheet 11 shows IA piping through penetrations P-33A and P-33B in four locations as in-scope for license renewal. This agrees with LRA Section 2.3.3.15 that states the in-scope portion of the IA subsystem includes those IA components that support the charging pump varidrives, pressurizer PORVs, and the IA containment isolation valves; however, the IA air piping continuation for these containment penetrations drawing LR-M-209, sheet 11 (at four locations B-1, C-1, C-6 and D-6) shows the IA piping as out-of-scope for license renewal. The transition location from in-scope (containment isolation) to out-of-scope (inside containment) is not clearly marked. If portions of these piping sections are out-of-scope for license renewal, their failure may affect the integrity of containment. Provide additional information to clarify the exact locations of these four transitions to clearly show which sections are in-scope and which are out-of-scope for license renewal.
Discussion: The applicant clarified their draft response. The applicant will provide their formal response in writing.
RAI 2.3.3.15 - 3 The PBNP UFSAR Section 9.7.1 states that the IA system shall automatically isolate the instrument air lines penetrating containment whenever a containment isolation signal exists to maintain containment integrity and prevent release of radioactivity to the outside environment.
Drawing LR-M-209, Sheet 7 shows four tanks and associated piping (listing below) as out-of-scope for license renewal. LRA Section 2.3.3.15 states that the in-scope portion of the IA subsystem includes those IA components that support the charging pump varidrives, pressurizer PORVs, and the IA containment isolation valves. Failure of these sections of piping depicted as not in-scope could affect the integrity of containment. Justify your determination of these tanks (listed below) and their associated piping to be not in-scope for license renewal and subject to AMR.
- a. 1T-196, location B-3
- b. 1T-197, location A-3
c.
T-196, location E-2
- d. T-197, location F-2 Discussion: The applicant clarified their draft response. The applicant will provide their formal response in writing.
2.3.4.1 Main and Auxiliary Steam System RAIs No RAIs are identified for the scoping and screening review for the Main and Auxiliary Steam System for the PBNP LRA.
2.3.4.2 Feedwater and Condensate System RAIs RAI 2.3.4.2-1 AS described in the PBNP UFSAR, Section 10.1, the primary function of the Feedwater system is to provide feedwater to the steam generators. Further, according to the LRA, portions of the Feedwater System also provide pressure boundary and flow paths to support auxiliary feedwater makeup to the steam generators. The license renewal drawings for the Feedwater and Condensate systems show the following listed piping/valves/fittings off of the feedwater pressure boundary as not in-scope for license renewal. Whereas, LRA Section 2.3.4.2 states that the feedwater and condensate piping and fittings are in-scope as a pressure boundary.
Failure of these sections of piping could affect the pressure boundary function of the Feedwater System. Provide additional information and justification as to why the piping areas listed below are not in-scope for license renewal and subject to an AMR.
- a. LR-M-202 SH-2, two sets of clean-out flanges, locations F-8 and C-8.
- b. LR-M-202 SH-2, two capped 3/8" ME with two in line valves, locations F-8 and C-8.
c.
LR-M-202 SH-2, two inlet lines from the Chem. Injection system, location F-9 and B-9.
- d. LR-M-202 SH-2, an outlet line to M-222 Sh. 1 location H-10v alve 145A, location F-7.
- e. LR-M-202 SH-2, an outlet line with valve 151A, location B-7.
f.
LR-M-202 SH-2, an outlet line to 1TE 2105, location C-9.
- g. LR-M-202 SH-2, an outlet line to 1PT 2289, location C-9.
- h. LR-M-202 SH-2, an outlet line to 1TX 2102, location C-8.
I.
LR-M-202 SH-2, an outlet line to 1TE 2104, location F-9.
- j.
LR-M-202 SH-2, an outlet line to 1PT 2290, location F-9.
- k. LR-M-202 SH-2, an outlet line to 1TX 2101, location F-8.
- l.
LR-M-202 SH-1, an outline to M-216 with valve 87, location D-10.
- m. LR-M-2202 SH-2, a clean-out flange, locations F-3 and C-3.
- n. LR-M-2202 SH-2, two capped 3/8" ME with two in line valves, locations F-3 and B-3.
- o. LR-M-2202 SH-2, two inlet lines with valves 180 and 167, location F-3 and B-3.
- p. LR-M-2202 SH-2, an outlet line to M-2222 Sh. 1 location G-6 with valve 145B at F-4.
- q. LR-M-2202 SH-2, an outlet line with valve 151A, location B-4.
- r. LR-M-2202 SH-2, an outlet line to 2TE 2105, location C-2.
- s. LR-M-2202 SH-2, an outlet line to 2PT 2289, location C-3.
- t. LR-M-2202 SH-2, an outlet line to 2TX 2102, location C-3.
- u. LR-M-2202 SH-2, an outlet line to 2TE 2104, location F-2.
- v. LR-M-2202 SH-2, an outlet line to 2PT 2290, location F-3.
- w. LR-M-2202 SH-2, an outlet line to 2TX 2101, location F-3.
- x. LR-M-2202 SH-1, an outline to M-216 with valve 87, location D-1.
Discussion: The applicant clarified their draft response. The applicant will provide their formal response in writing.
RAI 2.3.4.2-2 The PBNP UFSAR section 10.1 describes that the primary function of the Feedwater System is to provide feedwater to the steam generators. As described in the LRA, portions of the Feedwater system also provide pressure boundary and flow paths to support auxiliary feedwater makeup to the steam generators. The condenser manual fill line shown on license renewal drawing LR-M-202 sheet 1, at location D-10 is indicated to be within the scope of license renewal; however, a similar condenser manual fill line shown on license renewal drawing LR-M-2002 sheet 1 at location D-1 is not within the scope of license renewal. Failure of this section of piping could affect the pressure boundary function of the Feedwater System.
Justify your determination to exclude this section of piping from the scope of license renewal for the Unit 2 Feedwater System.
Discussion: The applicant clarified their draft response. The applicant will provide their formal response in writing.
RAI 2.3.4.2-3 The PBNP UFSAR section 10.1 describes the primary design system function of the Feedwater System including provisions for blowdown from the steam generators. Portions of the Engineered Safety Features Actuation System (ESFAS) also provide actuation signals for Feedwater System isolation including the steam generator blowdown lines. License renewal drawing LR-M-201 sheet 3, at location F-10 indicates that the blowdown lines from the Steam Generators A & B are within the scope of license renewal. However, drawing LR-M-2201, Sheet 3, at location F-1 indicates that these sections of steam generator blowdown pressure boundary piping are not within the scope of license renewal for Unit 2. Also note that drawing LR-M-201, Sheet 1, at location E-8 indicates this section of piping is not within the scope of license renewal for Unit 1 contrary to drawing LR-M-201, Sheet 3. If the blowdown lines from the steam generators are relied upon for a pressure boundary function and isolation on an ESFAS signal, then their failure could adversely impact their intended functions. Clarify which sections of the steam generator blowdown lines have pressure boundary functions and should be in-scope for license renewal and subject to an AMR. Further, justify your determination of those portions of the blowdown piping that are out-of-scope for license renewal.
Discussion: The applicant clarified their draft response. The applicant will provide their formal response in writing.
2.3.4.3 Auxiliary Feedwater System RAIs RAI 2.3.4.3 - 1 The PBNP UFSAR Section 10.2 states that the Auxiliary Feedwater System has several safety related functions including supplying high-pressure feedwater to the steam generators in order to maintain a water inventory for removal of heat energy from the reactor under specific accident conditions. Drawing LR-M-217, Sheet 2, quadrant B-2, identifies a portion of the Service Water return piping from AFW pump 1P-29 as outside the scope of license renewal.
This is inconsistent with the Drawing LR-M-207, Sheet 1A, quadrant B-9, that shows the return
Service Water piping from AFW pump 1P-29 as within the scope of license renewal. Failure of the out-of-scope return line may affect the pressure boundary integrity of the Auxiliary Feedwater System. Resolve these inconsistencies. Clarify whether this portion of Service Water piping is in-scope or not; If not, provide justification for not considering this piping for in-scope of license renewal.
Discussion: The applicant clarified their draft response. The applicant will provide their formal response in writing.
RAI 2.3.4.3 - 2 The PBNP UFSAR Section 10.2 states the Auxiliary Feedwater System has several safety related functions including supplying high-pressure feedwater to the steam generators in order to maintain a water inventory for removal of heat energy from the reactor under specific accident conditions. Drawing LR-M-217, Sheet 2, quadrant B-3, identifies a portion of the air supply piping to valve 1 MS 2090 as within the scope of license renewal. This is inconsistent with the Service Water license renewal drawing LR-M-207, Sheet 1A, quadrant C-10, which shows the pneumatic supply line to 1 MS 2090 as not in-scope of license renewal. Failure of the out-of-scope pneumatic supply line may adversely impact the safety-related functions of the Auxiliary Feedwater System. Clarify whether this portion of air supply piping is in-scope or not; if not, provide justification for not considering this piping for in-scope of license renewal.
Discussion: The applicant clarified their draft response. The applicant will provide their formal response in writing.
RAI 2.3.4.3 - 3 The PBNP UFSAR Section 10.2 states the Auxiliary Feedwater System has several safety related functions including supplying high-pressure feedwater to the steam generators in order to maintain a water inventory for removal of heat energy from the reactor under specific accident conditions. Drawing LR-M-217, Sheet 2, quadrant E-8 identifies a portion of the air supply piping to valve 2 MS 2090 as within the scope of license renewal. This is inconsistent with the Service Water license renewal drawing LR-M-207, Sheet 1A, quadrant G-10 that shows the pneumatic supply line to 2 MS 2090 as not within the scope of license renewal.
Failure of the out-of-scope pneumatic supply line may adversely impact the safety-related functions of the Auxiliary Feedwater system. Clarify whether this portion of air supply piping is in-scope or not; If not, provide justification for not considering this piping for in-scope of license renewal.
Discussion: The applicant clarified their draft response. The applicant will provide their formal response in writing.
RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION REGARDING POINT BEACH NUCLEAR PLANT, UNITS 1 AND 2 LICENSE RENEWAL APPLICATION (LRA)
The following information is provided in response to the Nuclear Regulatory Commission (NRC) staff's request for additional information (RAI) regarding License Renewal Application.
The NRC staff's questions are restated below, with Nuclear Management Company (NMC) response following.
Section 2.3.3 Auxiliary Systems 2.3.3.4 Waste Disposal System RAIs NRC Question RAI 2.3.3.4-1:
The PBNP UFSAR states that the Waste Disposal (WD) System discharge to the Service Water System has an automatic isolation function to prevent exceeding 10 CFR 20 and 100 limits due to high effluent radioactivity. The PBNP LRA Section 2.3.3.4 states that piping and valves credited for service water isolation from WD System components are in-scope.
However, the drain isolation valve WL-1785A and its inter-tie piping to the WD System are shown as not in-scope on license renewal drawing LR-684J971, Sheet 2, Unit 1 & 2 (Waste &
Blowdown Evaporator Distillate Process System), at location A-9. Failure of WL-1785A valve and its associated piping could cause a loss of this 10 CFR 20 and 10 CFR 100 required function. Justify your determination to exclude the WL-1785A valve and its associated piping from the scope of license renewal.
NMC Response:
This was a highlighting error on drawing LR-684J971, Sheet 2. WL-1785A and it associated piping are in-scope and subject to aging management. These are represented by the Valve Bodies and Piping and Fittings Component Types in Table 3.3.2-4 of the LRA.
NRC Question RAI 2.3.3.4-2:
The PBNP UFSAR states WD system discharge to the Service Water System has an automatic isolation function to prevent exceeding 10 CFR 20 and 100 limits due to high effluent radioactivity. The PBNP LRA Section 2.3.3.4 states that piping and valves credited for Service Water System isolation from WD components are in-scope. However, the license renewal application drawing LR-PBM-231, Sheet 1, Unit 1&2 De-ionized and Reactor Water Makeup Water at location F-7, indicates that valve RWM1249A and its downstream piping is not in-scope. Failure of RWM1249A and its downstream piping could cause a loss of the 10 CFR 20 and 10 CFR 100 required function. Justify your determination to exclude the RWM1249A valve and its downstream piping from the scope of license renewal.
NMC Response:
This was a highlighting error on drawing LR-PBM-231 Sheet 1. RMW-1249A and its associated piping are in-scope as shown on drawing LR-684J971 Sheet 2. This, however, was missed on drawing LR-PBM-231 Sheet 1. These components are in-scope and subject to aging management, and are represented by the Valve Bodies and Piping and Fittings Component Types in Table 3.3.2-4.
NRC Question RAI 2.3.3.4-3:
The PBNP LRA Section 2.3.3.4 states that principal components of the WD System within the scope of License Renewal include the heat exchangers with Component Cooling Water interfaces and the piping and valves that are credited for Service Water System isolation from WD System components. Drawing LR-684J971, Sheet 1 Unit 1-2, at location C-3 indicates that the following components are out-of-scope: the service water supply to HX-702 (Boric Acid Waste Evaporator Vacuum system Heat Exchanger), the interface with the HX, and the interface isolation valve BS-VA37. This is contrary to the information provided in the LRA and drawing LR-M-2207 sheet 1, Unit 2 service water at location A-9, which indicate these components are in-scope. There are also a number of WD/SW interface components on Drawing LR-684J971, Sheet 1 that are not shown do not appear on LR-M-2207, Sheet 1 and may need to be in-scope. Failure of these components could adversely impact the isolation functions between the WD System and other interfacing systems. Provide additional information and justify your determination for not considering these components to be in-scope for license renewal.
NMC Response:
This was a highlighting error on drawing LR-684J971 Sheet 1. HX-702, BS-VA37, and associated piping are in-scope as shown on drawing LR-M-2207 Sheet 1, and are subject to aging management. This, however, was missed as a continuation on drawing LR-684J971 Sheet 1. BS-VA37 is a normally closed valve that is only opened when starting up the vacuum pump and there is no other water in the system (the vacuum pump needs seal water). BS-VA37 and the tubes in HX-702 provide the in-scope boundary between Service Water (SW) and Waste Disposal (WD). These components are represented in the Heat Exchanger and Valve Bodies component types in Table 3.3.2-5 (Service Water System).
There are no other WD/SW interface components shown on this drawing, and therefore no other WD/SW components are considered in-scope. The other components on this drawing do not meet any of the scoping criteria, and are therefore not in-scope.
NRC Question RAI 2.3.3.4-4:
There are quite a few inconsistencies within the Waste Disposal system designations shown on the license renewal drawings which are identified as follows:
- a. The print-to-print inter-tie designator from LR-684J971, Sheet 2 Unit 1-2, Waste and Blowdown Evaporator Distillate Process system at location A-8 to the Service Water Overboard piping M-207 sheet 3 is not designated as in-scope.
- b. LR-684J971, sheet 2 Unit 1-2, Waste and Blowdown Evaporator Distillate Process system at location C-8 indicates the piping upstream of RWM1249A as in-scope. This is not consistent with drawing LR-PBM-231 sheet 1 Unit 1&2 De-ionized and Reactor Water Makeup Water.
c.
LR684J971, sheet 1 Unit 1-2, Waste Disposal system at location C-9 indicates the piping segment upstream of piping segment WD-151R-15 at location E-9 and downstream of isolation valve 1708 to be in-scope. There appears to be no LRA basis for this determination.
Failure of the above components currently designated as out-of-scope could have an adverse impact on the intended functions of the Waste Disposal System. Provide additional information to clarify your determinations as to which Waste Disposal System components, as described above, are in-scope for license renewal.
NMC Response:
- This was a highlighting error on drawing LR-684J971 Sheet 2. The print-to-print arrowhead should have been highlighted. However, the continuation on LR-M-207 Sheet 3 shows all necessary components that are considered in-scope. All in-scope components were previously addressed in the LRA.
- This is similar to the one identified in RAI 2.3.3.4-2. See response to RAI 2.3.3.4-2 in this letter.
- The basis for including these sections of pipe in-scope is for 10CFR54.4(a)(2). PBNP determined that there was potential for leakage or spray from these lines to affect safety related equipment. It is not easy to show these potential interactions on a P&ID, but we attempted to identify the in-scope portions as best we could. The in-scope boundary is where the pipe went through a wall into a different room, and therefore the boundary is not necessarily at a valve or other component. The Criterion a(2) walkdown result that brought the lines in question into scope is shown in LRA Table 2.1.2.1-1, p. 2-28, second line-item from the bottom.
2.3.3.8 Emergency Power - Support Systems for Emergency Diesels RAIs NRC Question RAI 2.3.3.8 - 1:
The PBNP UFSAR Section 8.8 states that the Diesel Generator (DG) system has several auxiliary support systems that must function in order to perform its safety related function including the air intake and exhaust system. License renewal drawing LR-M-226 shows the air intake oil bath filters inside the DG building with air intake screens shown on the building wall.
The air intake screens on the DG building walls are shown as out-of-scope of license renewal on license renewal drawing LR-M-226, Sheets 1 and 2 at location E-3. LRA Section 2.4.4 states that the DG building is a safety-related Seismic Class I structure but does not specifically address the air intake screens. Provide additional information and justify your determination to not include the diesel generator air intake screens in-scope for license renewal and subject to an AMR.
NMC Response:
This was a highlighting error on drawings LR-M-226 Sheets 1 and 2. The air intake screens are in-scope and subject to aging management. The air intakes are a chevron design, which are part of the structure, and are addressed as part of the civil/structural review (see Table 3.5.2-4, Structural, Carbon Steel, Outdoor - All: Missile Shields; Wall Plates at Missile Shields Component Type).
NRC Question RAI 2.3.3.8 - 2:
The PBNP UFSAR Section 8.8 states that the Diesel Generator (DG) system has several auxiliary support systems that must function in order to perform its safety related function including the fuel oil system. The instrument CS P105 and associated line on the gas turbine fuel oil supply pump P-105 is shown as out-of-scope of license renewal on license renewal drawing LR-M-219, Sheet 1 at location B-9. This is inconsistent with instruments CS P70A and CS P70B for fuel oil transfer pumps P-70A and P-70B which shows these instruments and their associated lines as in-scope. Failure of this instrument and its associated line may adversely impact the integrity of the gas turbine fuel oil transfer pump. A degraded gas turbine fuel oil transfer pump could adversely impact the station blackout function of the gas turbine generator.
Provide additional information to support your determination that it is acceptable to not include the instrument CS P105 and its associated line as in-scope for license renewal.
NMC Response:
This was a highlighting error on drawing LR-M-219 Sheet 1. Control switch CS P105 is in-scope, but it is an active component and therefore is not subject to aging management.
NRC Question RAI 2.3.3.8 - 3:
The PBNP UFSAR Section 8.8 states that the Diesel Generator (DG) system has several auxiliary support systems that must function in order to perform its safety related function including the fuel oil system. The instruments POS 3930 and CS 3930 and their associated lines on the DG day tank T-31A are shown as out-of-scope of license renewal on license renewal drawing LR-M-219, Sheet 1 at location G-3. This is inconsistent with instruments POS 3931 and CS 3931 for DG day tank T-31B which shows these instruments and their associated lines as in-scope. Failure of these instruments and their associated lines may adversely impact the integrity of the supply lines to the DG day tank. A degraded DG day tank supply could adversely impact the safety-related function of the G01 diesel generator. Provide additional information to support your determination that it is acceptable to not include the instruments POS 3930 and CS 3930 and their associated lines as in-scope for license renewal.
NMC Response:
This was a highlighting error on drawing LR-M-219 Sheet 1. Position switch POS 3930 and control switch CS 3930 are in-scope, but they are active components, and therefore are not subject to aging management.
NRC Question RAI 2.3.3.8 - 4:
The PBNP UFSAR Section 8.8 states that the Diesel Generator (DG) system has several auxiliary support systems that must function in order to perform its safety related function including the fuel oil system. The solenoid vent valve FO 3922 S on flow control valve FC 3922 is shown as in-scope for license renewal on license renewal drawing LR-M-219, Sheet 1 at location G-4. The line to this solenoid vent valve is shown as out-of-scope for license renewal.
In addition, the solenoid vent valve FO 3923 S on flow control valve FC 3923 is shown as out-of-scope at location E-9. A degraded DG fuel oil supply system could adversely impact the safety-related function of the diesel generators. Provide additional information to clarify why only solenoid vent valve FO 3922 S on FC 3922 is shown as in-scope, while the associated lines and the similar vent valve configuration on FC 3923 are not shown in-scope for license renewal.
NMC Response:
This is partially a highlighting error on drawing LR-M-219 Sheet 1. FO 3923 S (solenoid valve for FO 3923) is in-scope, however it is an active component and not subject to aging management.
The air lines between the solenoid valves and the air operated valves (AOVs) are not shown in-scope, as these air lines have no license renewal intended function (if the air lines fail, the AOVs fail to their intended position - closed, and thereby meet the AOVs intended function).
NRC Question RAI 2.3.3.8 - 5:
The PBNP UFSAR Section 8.8 states that the Diesel Generator (DG) system has several auxiliary support systems that must function in order to perform its safety related function including the fuel oil system. The 20 man way, SAX 7907, 3 inch vent lines and LS 3942 on the emergency fuel tank T-72 are shown as out-of-scope for license renewal on license renewal drawing LR-M-219, Sheet 1 at location C-5. This is inconsistent with the 24 man way, SAX 7913A, 4 inch vent lines and LS 3933A for DG storage tank T-175A shown on license renewal drawing LR-M-219, Sheet 2 which shows similar equipment on T-175A as in-scope. A degraded DG emergency fuel tank T-72 could adversely impact the emergency fuel supply and the safety-related function of the diesel generators. Provide additional information to support your determination that the 20" man way, SAX 7907, 3 inch vent lines and LS 3942 on the emergency fuel tank are out-of-scope for license renewal.
NMC Response:
This was a highlighting error on drawing LR-M-219 Sheet 1. The manway, sample point SAX 7907, and the 3-inch vent lines are in-scope and subject to aging management. These components are represented by the Tank and Piping and Fittings Component Types in Table 3.3.2-7 of the LRA.
Level switch LS 3942 is also in-scope, but it is an active component, and therefore is not subject to aging management.
2.3.3.14 Plant Sampling System RAIs No RAIs are identified for the scoping and screening review for the Plant Sampling system for the PBNP LRA.
2.3.3.15 Plant Air System RAIs NRC Question RAI 2.3.3.15 - 1:
The PBNP UFSAR Section 9.7.1 states, The IA [Instrument Air] system shall automatically isolate the purge supply and exhaust valve accumulators, including the supplemental nitrogen bottle system for 2VNPSE-3212 and 2VNPSE-3244, from the IA system during a loss of instrument air to maintain containment integrity and prevent release of radioactivity to the outside environment. Drawing LR-PBM-2332 shows two valve actuators (listed below) as out-of-scope for license renewal. LRA Section 2.3.3.15 states that the valve bodies are in-scope as a pressure boundary. The two valve actuators are not shown on plant drawings in a manner that is consistent with other similar valves in the IA system. If portions of these valves have pressure boundary functions that are not in-scope, their failure could adversely impact the IA system pressure boundary function. Provide clarification and justification as to why the following valve actuators are not shown as in-scope for license renewal and subject to an AMR.
- a. LR-PBM-2332 - Actuator for 2VNPSE-3212, location E-2.
- b. LR-PBM-2332 - Actuator for 2VNPSE-3244, location E-6.
NMC Response:
This was a highlighting error on drawing LR-PBM-2332. The solenoid actuators are in-scope, but are active portions of the valves and therefore not subject to aging management. Note that the bodies of the solenoid valves are in-scope as shown, and in this case, since they do have a pressure boundary intended function, they are subject to aging management. These valves are represented by the Valve Bodies Component Type in Table 3.3.2-11 of the LRA.
NRC Question RAI 2.3.3.15 - 2:
The PBNP UFSAR Section 9.7.1 states, The IA system shall automatically isolate the instrument air lines penetrating containment whenever a containment isolation signal exists to maintain containment integrity and prevent release of radioactivity to the outside environment.
Drawing LR-M-209, Sheet (7)11 shows IA piping through penetrations P-33A and P-33B in four locations as in-scope for license renewal. This agrees with LRA Section 2.3.3.15 that states the in-scope portion of the IA subsystem includes those IA components that support the charging pump varidrives, pressurizer PORVs, and the IA containment isolation valves; however, the IA air piping continuation for these containment penetrations drawing LR-M-209, sheet 11 (at four locations B-1, C-1, C-6 and D-6) shows the IA piping as out-of-scope for license renewal. The transition location from in-scope (containment isolation) to out-of-scope (inside containment) is not clearly marked. If portions of these piping sections are out-of-scope for license renewal, their failure may affect the integrity of containment. Provide additional information to clarify the exact locations of these four transitions to clearly show which sections are in-scope and which are out-of-scope for license renewal.
NMC Response:
This was a highlighting error on drawing LR-M-209 Sheet 11. The containment isolation function for the PBNP Instrument Air System is performed by two valves outside containment for each line, as shown on drawing LR-M-209 Sheet 7 (locations B-4 and E-3) The valves and piping up to and including the penetration are in-scope and subject to aging management. The piping adjacent to the penetrations inside containment is not in-scope. LR-M-209 Sheet 11 should have shown the scope-break at the penetration.
NRC Question RAI 2.3.3.15 - 3:
The PBNP UFSAR Section 9.7.1 states that the IA system shall automatically isolate the instrument air lines penetrating containment whenever a containment isolation signal exists to maintain containment integrity and prevent release of radioactivity to the outside environment.
Drawing LR-M-209, Sheet 7 shows four tanks and associated piping (listing below) as out-of-scope for license renewal. LRA Section 2.3.3.15 states that the in-scope portion of the IA subsystem includes those IA components that support the charging pump varidrives, pressurizer PORVs, and the IA containment isolation valves. Failure of these sections of piping depicted as not in-scope could affect the integrity of containment. Justify your determination of these tanks (listed below) and their associated piping to be not in-scope for license renewal and subject to AMR.
- a. 1T-196, location B-3
- b. 1T-197, location A-3 c.
T-196, location E-2
- d. T-197, location F-2 NMC Response:
The four tanks referenced in this question are small air accumulators on the air line to the actuators. These tanks and their associated piping are correctly shown to be not in-scope, as they perform no intended function and cannot affect the containment isolation function of the containment isolation valve. If these tanks or piping fail, it would cause air to bleed off the actuator and thereby cause the containment isolation valve to close, its fail-safe position.
Therefore, these tanks and associated piping are considered to be not in-scope.
2.3.4.1 Main and Auxiliary Steam System RAIs No RAIs are identified for the scoping and screening review for the Main and Auxiliary Steam System for the PBNP LRA.
2.3.4.2 Feedwater and Condensate System RAIs NRC Question RAI 2.3.4.2-1:
As described in the PBNP UFSAR, Section 10.1, the primary function of the Feedwater system is to provide feedwater to the steam generators. Further, according to the LRA, portions of the Feedwater System also provide pressure boundary and flow paths to support auxiliary feedwater makeup to the steam generators. The license renewal drawings for the Feedwater and Condensate systems show the following listed piping/valves/fittings off of the feedwater pressure boundary as not in-scope for license renewal. Whereas, LRA Section 2.3.4.2 states that the feedwater and condensate piping and fittings are in-scope as a pressure boundary.
Failure of these sections of piping could affect the pressure boundary function of the Feedwater System. Provide additional information and justification as to why the piping areas listed below are not in-scope for license renewal and subject to an AMR.
- a. LR-M-202 SH-2, two sets of clean-out flanges, locations F-8 and C-8.
- b. LR-M-202 SH-2, two capped 3/8" ME with two in line valves, locations F-8 and C-8.
c.
LR-M-202 SH-2, two inlet lines from the Chem. Injection system, location F-9 and B-9.
- d. LR-M-202 SH-2, an outlet line to M-222 Sh. 1 location H-10v alve 145A, location F-7.
- e. LR-M-202 SH-2, an outlet line with valve 151A, location B-7.
f.
LR-M-202 SH-2, an outlet line to 1TE 2105, location C-9.
- g. LR-M-202 SH-2, an outlet line to 1PT 2289, location C-9.
- h. LR-M-202 SH-2, an outlet line to 1TX 2102, location C-8.
I.
LR-M-202 SH-2, an outlet line to 1TE 2104, location F-9.
- j.
LR-M-202 SH-2, an outlet line to 1PT 2290, location F-9.
- k. LR-M-202 SH-2, an outlet line to 1TX 2101, location F-8.
- l.
LR-M-202 SH-1, an outline to M-216 with valve 87, location D-10.
- m. LR-M-2202 SH-2, a clean-out flange, locations F-3 and C-3.
- n. LR-M-2202 SH-2, two capped 3/8" ME with two in line valves, locations F-3 and B-3.
- o. LR-M-2202 SH-2, two inlet lines with valves 180 and 167, location F-3 and B-3.
- p. LR-M-2202 SH-2, an outlet line to M-2222 Sh. 1 location G-6 with valve 145B at F-4.
- q. LR-M-2202 SH-2, an outlet line with valve 151A, location B-4.
- r. LR-M-2202 SH-2, an outlet line to 2TE 2105, location C-2.
- s. LR-M-2202 SH-2, an outlet line to 2PT 2289, location C-3.
- t. LR-M-2202 SH-2, an outlet line to 2TX 2102, location C-3.
- u. LR-M-2202 SH-2, an outlet line to 2TE 2104, location F-2.
- v. LR-M-2202 SH-2, an outlet line to 2PT 2290, location F-3.
- w. LR-M-2202 SH-2, an outlet line to 2TX 2101, location F-3.
- x. LR-M-2202 SH-1, an outline to M-216 with valve 87, location D-1.
NMC Response:
The primary safety functions of the Feedwater and Condensate system are to provide containment isolation and maintain capability for heat removal via the steam generators. Both of these functions are accomplished by the two check valves in the main feed lines, just upstream of the steam generators (auxiliary feedwater makeup is downstream of these check valves). For these reasons, the 16 main feed headers between these check valves and the Feedwater Regulating valves are non-safety related. These headers, however, were included in-scope due to criterion a(2), due to potential HELB interactions with nearby safety-related equipment (see LRA Table 2.1.2.1-1, p. 2-25, first line item). The question identifies branches off of the main feedwater headers that are shown to be not in-scope. Branches off of the main feed headers that are 1-inch and under were not included in-scope as they are not considered in HELB evaluations (per NRC guidance for HELB evaluations - see PBNP FSAR Appendix A.2 Reference 1: General Information Required for Consideration of the Effects of a Piping System Break Ouside of Contaiment, AEC, December 19, 1972). Since connections 1-inch and under are not required to be considered in HELB evaluations, and since they would not likely provide sufficient energy to create a harsh environment (as defined by PBNP Equipment Qualification (EQ) Program), only the header itself was included in-scope for potential HELB concerns. Therefore, branch connections 1-inch and under, on the in-scope non-safety related portions of the main feedwater headers, are considered to be not in-scope.
The clean-out flanges identified in items a. and m. above, are larger than 1-inch, and should have been highlighted. These clean-out flanges are in-scope and subject to aging management, and are already addressed in the Piping and Fittings Component Type in Table 3.4.2-2 of the LRA.
Note that feedwater flow transmitters 1/2FT-466, -467, -476, -477, and their associated small bore piping and isolation valves are shown in-scope. This is because these transmitters and their associated piping and valves are safety-related, and as such, they are included in-scope.
NRC Question RAI 2.3.4.2-2:
The PBNP UFSAR section 10.1 describes that the primary function of the Feedwater System is to provide feedwater to the steam generators. As described in the LRA, portions of the Feedwater system also provide pressure boundary and flow paths to support auxiliary feedwater makeup to the steam generators. The condenser manual fill line shown on license renewal drawing LR-M-202 sheet 1, at location D-10 is indicated to be within the scope of license renewal; however, a similar condenser manual fill line shown on license renewal drawing LR-M-2002 sheet 1 at location D-1 is not within the scope of license renewal. Failure of this section of piping could affect the pressure boundary function of the Feedwater System.
Justify your determination to exclude this section of piping from the scope of license renewal for the Unit 2 Feedwater System.
NMC Response:
This was a highlighting error on drawing LR-M-2002 Sheet 1. The manual fill line, up to and including valves 2CS-86 and 2CS-87, is in-scope and subject to aging management. These components are represented by the Piping and Fittings and Valve Bodies Component Types in Table 3.4.2-2 of the LRA.
NRC Question RAI 2.3.4.2-3:
The PBNP UFSAR section 10.1 describes the primary design system function of the Feedwater System including provisions for blowdown from the steam generators. Portions of the Engineered Safety Features Actuation System (ESFAS) also provide actuation signals for Feedwater System isolation including the steam generator blowdown lines. License renewal drawing LR-M-201 sheet 3, at location F-10 indicates that the blowdown lines from the Steam Generators A & B are within the scope of license renewal. However, drawing LR-M-2201, Sheet 3, at location F-1 indicates that these sections of steam generator blowdown pressure boundary piping are not within the scope of license renewal for Unit 2. Also note that drawing LR-M-201, Sheet 1, at location E-8 indicates this section of piping is not within the scope of license renewal for Unit 1 contrary to drawing LR-M-201, Sheet 3. If the blowdown lines from the steam generators are relied upon for a pressure boundary function and isolation on an ESFAS signal, then their failure could adversely impact their intended functions. Clarify which sections of the steam generator blowdown lines have pressure boundary functions and should be in-scope for license renewal and subject to an AMR. Further, justify your determination of those portions of the blowdown piping that are out-of-scope for license renewal.
NMC Response:
This was a highlighting error on drawing LR-M-2201 Sheet 3. The upstream piping is in-scope, as indicated on LR-M-2201 Sheet 1, but the transition arrow was missed on LR-M-2201 Sheet 3.
In all cases (both units, both trains), the blowdown piping between the steam generators up to and including valves 1/2MS-2042 and 1/2MS-2045, is in-scope and subject to aging management.
2.3.4.3 Auxiliary Feedwater System RAIs NRC Question RAI 2.3.4.3 - 1:
The PBNP UFSAR Section 10.2 states that the Auxiliary Feedwater System has several safety related functions including supplying high-pressure feedwater to the steam generators in order to maintain a water inventory for removal of heat energy from the reactor under specific accident conditions. Drawing LR-M-217, Sheet 2, quadrant B-2, identifies a portion of the Service Water return piping from AFW pump 1P-29 as outside the scope of license renewal.
This is inconsistent with the Drawing LR-M-207, Sheet 1A, quadrant B-9, that shows the return Service Water piping from AFW pump 1P-29 as within the scope of license renewal. Failure of the out-of-scope return line may affect the pressure boundary integrity of the Auxiliary Feedwater System. Resolve these inconsistencies. Clarify whether this portion of Service Water piping is in-scope or not; If not, provide justification for not considering this piping for in-scope of license renewal.
NMC Response:
This was a highlighting error on drawing LR-M-217 Sheet 2. Service water piping supply and return for the AFW pump bearings is in-scope (as shown on LR-M-207 Sheet 1A), and subject to aging management.
NRC Question RAI 2.3.4.3 - 2:
The PBNP UFSAR Section 10.2 states the Auxiliary Feedwater System has several safety related functions including supplying high-pressure feedwater to the steam generators in order to maintain a water inventory for removal of heat energy from the reactor under specific accident conditions. Drawing LR-M-217, Sheet 2, quadrant B-3, identifies a portion of the air supply piping to valve 1 MS 2090 as within the scope of license renewal. This is inconsistent with the Service Water license renewal drawing LR-M-207, Sheet 1A, quadrant C-10, which shows the pneumatic supply line to 1 MS 2090 as not in-scope of license renewal. Failure of the out-of-scope pneumatic supply line may adversely impact the safety-related functions of the Auxiliary Feedwater System. Clarify whether this portion of air supply piping is in-scope or not; if not, provide justification for not considering this piping for in-scope of license renewal.
NMC Response:
This was a highlighting error on drawing LR-M-217 Sheet 2. The solenoid valve associated with 1MS 2090 is in-scope, but it is an active component and therefore is not subject to aging management. The air piping between the solenoid and valve is not in-scope, because it has no intended function. If this air tubing were to fail, the valve would go to its fail-safe position, and would not affect the intended function of the valve (i.e., to supply SW to the bearings).
NRC Question RAI 2.3.4.3 - 3:
The PBNP UFSAR Section 10.2 states the Auxiliary Feedwater System has several safety related functions including supplying high-pressure feedwater to the steam generators in order to maintain a water inventory for removal of heat energy from the reactor under specific accident conditions. Drawing LR-M-217, Sheet 2, quadrant E-8 identifies a portion of the air supply piping to valve 2 MS 2090 as within the scope of license renewal. This is inconsistent with the Service Water license renewal drawing LR-M-207, Sheet 1A, quadrant G-10 that shows the pneumatic supply line to 2 MS-2090 as not within the scope of license renewal.
Failure of the out-of-scope pneumatic supply line may adversely impact the safety-related functions of the Auxiliary Feedwater system. Clarify whether this portion of air supply piping is in-scope or not; If not, provide justification for not considering this piping for in-scope of license renewal.
NMC Response:
This was a highlighting error on drawing LR-M-217 Sheet 2. The solenoid valve associated with 2MS 2090 is in-scope, but it is an active component and therefore is not subject to aging management. The air piping between the solenoid and valve is not in-scope, because it has no intended function. If this air tubing were to fail, the valve would go to its fail-safe position, and would not affect the intended function of the valve (i.e., to supply SW to the bearings).