January 12, 2005 LICENSEE:

Indiana Michigan Power Company FACILITY:

Donald C. Cook Nuclear Plant, Units 1 and 2

SUBJECT:

SUMMARY

OF TELEPHONE CONFERENCE CALL HELD ON NOVEMBER 23, 2004, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND INDIANA MICHIGAN POWER COMPANY, CONCERNING LICENSE RENEWAL ISSUES PERTAINING TO THE DONALD C. COOK NUCLEAR PLANT, UNITS 1 AND 2, LICENSE RENEWAL APPLICATION The U.S. Nuclear Regulatory Commission staff (the NRC or the staff) and representatives of Indiana Michigan Power Company (I&M) held a telephone conference call on November 23, 2004, to discuss and clarify issues related to the aging management program (AMP) inspection of various programs concerning the Donald C. Cook Nuclear Plant, Units 1 and 2, license renewal application. provides a listing of the meeting participants. Enclosure 2 contains a items discussed with the applicant, including a brief description on the status of the items.

The applicant had an opportunity to comment on this summary.

/RA/

Jonathan Rowley, Project Manager License Renewal Section A License Renewal and Environmental Impacts Program Division of Regulatory Improvement Programs Office of Nuclear Reactor Regulation Docket Nos.: 50-315 and 50-316

Enclosures:

As stated cc w/encls: See next page

ML050120443 DOCUMENT NAME: E:\\Filenet\\ML050120443.wpd OFFICE PM:RLEP LA:RLEP SC:RLEP NAME J. Rowley M. Jenkins S. Lee DATE 1/6/05 1/5 /05 1/12/05

Donald C. Cook Nuclear Plant, Units 1 and 2 cc:

Regional Administrator, Region III U.S. Nuclear Regulatory Commission 2443 Warrenville Road, Suite 210 Lisle, IL 60532-4351 Township Supervisor Lake Township Hall P.O. Box 818 Bridgman, MI 49106 U.S. Nuclear Regulatory Commission Resident Inspectors Office 7700 Red Arrow Highway Stevensville, MI 49127 David W. Jenkins, Esquire Indiana Michigan Power Company One Cook Place Bridgman, MI 49106 Mayor, City of Bridgman P.O. Box 366 Bridgman, MI 49106 Special Assistant to the Governor Room 1 - State Capitol Lansing, MI 48909 Mr. John A. Zwolinski Director, Design Engineering and Regulatory Affairs Indiana Michigan Power Company Nuclear Generation Group 500 Circle Drive Buchanan, MI 49107 Patricia Lougheed 2443 Warrenville Rd.

Lisle, IL 60532 Michigan Department of Environmental Quality Waste and Hazardous Materials Div.

Hazardous Waste & Radiological Protection Section Nuclear Facilities Unit Constitution Hall, Lower-Level North 525 West Allegan Street P.O. Box 30241 Lansing, MI 48909-7741 Michael J. Finissi, Plant Manager Indiana Michigan Power Company Nuclear Generation Group One Cook Place Bridgman, MI 49106 Mr. Joseph N. Jensen, Site Vice President Indiana Michigan Power Company Nuclear Generation Group One Cook Place Bridgman, MI 49106 Mr. Fred Emerson Nuclear Energy Institute 1776 I Street, N.W., Suite 400 Washington, DC 20006-3708 Richard J. Grumbir Project Manager, License Renewal Indiana Michigan Power Company Nuclear Generation Group 500 Circle Drive Buchanan, MI 49107

DISTRIBUTION: Note to Indiana Michigan Power Co., Re: Donald C. Cook, Nuclear Plant, Units 1 and 2, Dated: January 12, 2005 Adams accession no.: ML050120443 HARD COPY RLEP RF J. Rowley, Project Manager E-MAIL:

RidsNrrDrip RidsNrrDe G. Bagchi K. Manoly W. Bateman J. Calvo R. Jenkins P. Shemanski J. Fair RidsNrrDssa RidsNrrDipm D. Thatcher R. Pettis G. Galletti C. Li M. Itzkowitz (RidsOgcMailCenter)

R. Weisman M. Mayfield A. Murphy S. Smith (srs3)

S. Duraiswamy Y. L. (Renee) Li RLEP Staff C. Julian M. Modes J. Vora L. Kozak J. Donohew PMNS G. Galletti L. Lund S. Coffin T. Chan J. Minns R. Gramm A. Howell M. Shuaibi J. Strasma, RIV M. Kotzalas OPA NRR/ADPT secretary (RidsNrrAdpt)

LIST OF PARTICIPANTS FOR TELEPHONE CONFERENCE CALL TO DISCUSS THE DONALD C. COOK NUCLEAR PLANT, UNITS 1 AND 2 LICENSE RENEWAL APPLICATION NOVEMBER 23, 2004 Participants Affiliations Jonathan Rowley U.S. Nuclear Regulatory Commission (NRC)

Gregory Cranston NRC Gregory Makar NRC James Neurauter NRC Richard Grumbir Indiana Michigan Power Company (I&M)

Neil Haggerty I&M Robert Kalinowski I&M Glen Bradham I&M Phil Kohn I&M Alberto Verteramo I&M Alan Cox Entergy*

  • I&M contractor AGING MANAGEMENT PROGRAM ISSUES RELATED TO DONALD C. COOK NUCLEAR PLANT, UNITS 1 AND 2 LICENSE RENEWAL APPLICATION NOVEMBER 23, 2004 The U.S. Nuclear Regulatory Commission staff (the staff) and representatives of Indiana Michigan Power Company (I&M) held a telephone conference call on November 23, 2004, to discuss and clarify issues related to the aging management program (AMP) inspection of various programs concerning the Donald C. Cook Nuclear Plant (CNP), Units 1 and 2, license renewal application (LRA). The following issues were discussed during the telephone conference call.

Boral Surveillance Program, LRA section B.1.3 There may be a discrepancy in the Monitoring and Trending element of CNPs Boral Surveillance Program. The LRA states, ?The periodic inspection measurements and analysis are compared to values of previous measurements and analysis to provide data for trend analysis. The statement was interpreted by the staff that CNP uses data trending. The staff performed its AMP review on that basis. I&M stated that the Monitoring and Trending element did not state that trending is performed, nor was it intended to imply that trending is performed.

Discussion: The staff will consider the applicants clarification. If necessary, the staff will send a formal RAI.

Flow Accelerated Corrosion Program, LRA Section B.1.12 In CNP LRA, Appendix B, Section B.1.12, the applicant states that CNP AMP B1.12, ?Flow-Accelerated Corrosion Program, is consistent with NUREG-1801,Section XI.M17. Following the AMP inspection, the staff has determined that CNPs Flow Accelerated Corrosion (FAC)

Program is consistent with a possible exception. The Acceptance Criteria and the Monitoring and Trending elements of NUREG-1801,Section XI.M17 require that if actual measured degradation is greater than the predicted degradation, then additional examinations are performed in adjacent areas to bound the thinning. However, the CNP FAC program bases its sample expansion determination on a threshold criteria rather than on predicted thickness.

Sample size is increased when inspections detect significant FAC wear resulting in a wall thickness threshold of less than or equal to 60 percent of nominal wall thickness.

Discussion: Based on the discussion with the applicant, the staff may issue a formal RAI to address the inconsistency with NUREG-1801 for the CNP FAC Program.

System Testing Program, LRA Section B.1.37 The CNP LRA states that the Letdown Orifices Test data is recorded hourly in the plants Critical Parameters Log. The AMP inspection revealed that the data is no longer recorded hourly in the plants Critical Parameters Log, but is actually recorded continuously in the Plant Process Computer.

Discussion: Based on the discussion with the applicant, the staff indicated that recording the data in the computer rather than the log is acceptable. The subject will be docketed appropriately by either issuance of an RAI or by formal supplement letter from the applicant.