From:
Kenneth R. Worthington <krworthington@aep.com>
To:
<infocollects@nrc.gov>
Date:
12/3/04 12:17PM
Subject:
Response from "Comment on NRC Documents" Below is the result of your feedback form. It was submitted by Kenneth R. Worthington (krworthington@aep.com) on Friday, December 03, 2004 at 12:14:04 Document_Title: NRC Draft Generic Letter 2004-XXX, Steam Generator Tube Integrity and Associated Technical Specifications.
Comments: 1. In recirculating steam generators, the largest tube loads occur in the upper bundle (U-bend) region. Wear marks from debris can have a strong circumferential character, but are typically not found in the upper bundle. Since the primary bending moments acting on the tubes near the tubesheet are small, the assessment of such wear marks is not expected to be impacted by the new SIPC. However, if definite evidence is needed that an analysis based on pressure differential is in fact bounding, it may be necessary to calculate the plant specific tube loads near the tubesheet. These are not available in the present tube stress evaluation conducted in accordance with Regulatory Guide 1.121 since this location does not see the highest loads. This will require a considerable expense to each utility to backfit and, for most utilities, will also require the assistance of the original equipment manufacturer to perform the calculations since appropriate tube loads to perfor!
m the calculations do not currently reside in the plant specific stress reports. Requiring each utility to provide a plant specific analysis to show that the analysis based on pressure differential is bounding appears to be overly burdensome and does not significantly contribute to increasing the health and safety of the public.
organization: American Electric Power - Cook Nuclear Plant address1: One Cook Place address2:
city: Bridgman state: MI zip: 49106 country: United States phone: 269-465-5901
Mail Envelope Properties (41B09FB3.FA2 : 20 : 49058)
Subject:
Response from "Comment on NRC Documents" Creation Date:
12/3/04 12:14PM From:
Kenneth R. Worthington <krworthington@aep.com>
Created By:
krworthington@aep.com Recipients nrc.gov twf3_po.TWFN_DO INFOCOLLECTS Post Office Route twf3_po.TWFN_DO nrc.gov Files Size Date & Time MESSAGE 1943 12/03/04 12:14PM Mime.822 2658 Options Expiration Date:
None Priority:
Standard Reply Requested:
No Return Notification:
None Concealed
Subject:
No Security:
Standard