ML043480419

From kanterella
Jump to navigation Jump to search
Requalification Program Inspection Ginna Nuclear Power Plant Planned for February 13, 2005
ML043480419
Person / Time
Site: Ginna 
(DPR-018)
Issue date: 12/13/2004
From: Conte R
NRC/RGN-I/DRS/OSB
To: Korsnick M
Ginna
References
Download: ML043480419 (3)


Text

December 13, 2004 Mrs. Mary G. Korsnick Vice President R. E. Ginna Nuclear Power Plant R. E. Ginna Nuclear Power Plant, LLC 1503 Lake Road Ontario, NY 14519

SUBJECT:

REQUALIFICATION PROGRAM INSPECTION GINNA NUCLEAR POWER PLANT

Dear Mrs. Korsnick:

In a telephone conversation on December 6, 2004, Mr. Steven Dennis, Senior Operations Examiner and Mr. Frank Maciuska, Director Operations Training, made arrangements for the NRC to inspect the licensed operator requalification program at the Ginna facility. The inspection is planned for the week of February 13, 2005, which coincides with your regularly scheduled requalification examination cycle. The staff at your facility should prepare and conduct the requalification examinations in accordance with your NRC-approved requalification program.

In accordance with 10 CFR 55.59(c), the NRC may request facility licensees to submit their comprehensive requalification written examinations or annual operating tests as necessary to support the NRC's inspection program needs. In order for the NRC to adequately prepare for this inspection, please furnish: 1) an index or summary of condition reports written in the past two years in which licensed operator errors were determined to be the root or contributing cause; 2) an index or summary of condition reports written in the past two years on simulator performance problems; 3) an index or summary of simulator performance test results in the past two years; and 4) the examination schedule, sample plan, written examinations and operating test scheduled for the week of the inspection to the NRC by January 24, 2005.

Mr. Maciuska has been advised of this request and provided with the name and address of the NRC lead inspector assigned to this inspection.

This letter contains information collections that are subject to the Paperwork Reduction Act of 1995 (44 U.S.C. 3501 et seq.). These information collections were approved by the Office of Management and Budget, approval number 3150-0018, which expires on June 30, 2006.

The public reporting burden for this collection of information is estimated to average four hours per response, including the time for reviewing instructions, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments on any aspect of this collection of information, including suggestions for reducing the burden, to the Information and Records Management Branch (T-6 F33), U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001, or by Internet electronic mail at: SLF@NRC.GOV, and to the Desk Officer, Office of Information and Regulatory Affairs, NEOB-10202, (3150-0101), Office of Management and Budget, Washington, DC 20503.

2 Mrs. Mary G. Korsnick The NRC may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB control number.

Thank you for your cooperation in this matter. If you have any questions regarding this inspection, please contact Mr. Steven Dennis at (610) 337-5048.

Sincerely,

/RA/

Richard J. Conte, Chief Operational Safety Branch Division of Reactor Safety Docket No.

50-244 License No.

DPR-18 cc w/encl:

M. J. Wallace, President, Constellation Generation J. M. Heffley, Senior Vice President and Chief Nuclear Officer P. Eddy, Electric Division, NYS Department of Public Service C. Donaldson, Esquire, Assistant Attorney General, New York Department of Law J. M. Petro, Jr., Esquire, Counsel, Constellation Energy Group, Inc.

P. R. Smith, New York State Energy Research and Development Authority J. Spath, Program Director, New York State Energy Research and Development Authority D. Stenger, Ballard, Spahr, Andrews and Ingersoll, LLP T. Wideman, Director, Wayne County Emergency Management Office M. Meisenzahl, Administrator, Monroe County, Office of Emergency Preparedness T. Judson, Central New York Citizens Awareness Network R. Watts, Manager, Nuclear Training F. Maciuska, Director, Operations Training

3 Mrs. Mary G. Korsnick Distribution: (via e-mail)

S. Collins, RA J. Wiggins, DRA J. Jolicoeur, OEDO R. Laufer, NRR R. Clark, PM, NRR P. Milano, PM, NRR (Backup)

L. Vick, HOHB, NRR S. Glenn, INPO (GlennSG@Inpo.org)

J. Trapp, DRP N. Perry, DRP W. Lanning, DRS R. Conte, DRS C. Bixler, DRS (OL Facility File)

K. Kolaczyk, DRP, SRI M. Marshfield, DRP, RI S. DiMora, DRP, OA Region I Docket Room (with concurrences)

SISP Review Complete: RJC DOCUMENT NAME: E:\\Filenet\\ML043480419.wpd After declaring this document An Official Agency Record it will be released to the Public.

ADAMS PKG: ML043410165 To receive a copy of this document, indicate in the box: "C" = Copy without attachment/enclosure "E" = Copy with attachment/enclosure "N" = No copy OFFICE RI/DRS/OSB RI/DRS/OSB RI/DRS/OSB NAME CBixler/CJB SDennis/SD RConte/RJC DATE 12/7/04 12/7/04 12/10/04 OFFICIAL RECORD COPY