Research Reactor Center University of Missouri-Columbia Research Park Columbia, MO 65211 PioNE (573) 8824211 FAx (573) 882-6360 October 12, 2004 Mr. Alexander Adams, Jr.
U.S. Nuclear Regulatory Commission Mail Stop 012-G13 Washington, DC 20555-0001
SUBJECT:
University of Missouri Research Reactor Facility Docket No. 50-186 Monthly Operations Summary
Dear Mr. Adams:
Enclosed is a copy of MURR's Monthly Operations Summary for September 2004. If you have any questions, please contact me at (573) 882-5276.
Sincerely, Leslie Foyto Reactor Manager LM/sm cc. Craig Bassett
Enclosure:
September Operation Summary - 4 pages yC_0 2Y AN EQUAL OPPOR'rUrY/ADA LNsTrnUrION
QUrVERSIVYOf.*J4r 155011 PI RESEAR¶'kC-f REACTOR OPET.A'YITOJS !MO*Af-LY SWMAlvtfRY September 2004 Preyaredby:
Oyerations Staff
INTRODUCTION The reactor operated continuously in September with the following exceptions: 4 shutdowns for scheduled maintenance and refueling; 1 unscheduled shutdown.
MAINTENANCE ACTIVITIES 9/6/04 Refueled - removed core 04-41, loaded core 04-42.
Performed backflush on the Pool Coolant System Heat Exchanger.
9/13/04 Refueled - removed core 04-42, loaded core 04-43.
Completed Modification Record 88-11, Add. 1; "Upgrade of Uninterruptible Power Supply Alternate Source."
9/20/04 Refueled - removed core 04-43, loaded core 04-44.
Completed Modification Record 04-4; "Reactor Control Console Upgrade."
Replaced isolator on Nuclear Instrumentation Signal Processor Drawer No. 1.
9/25/04 Refueled - removed core 04-44, loaded core 04-45.
Replaced cabling and fission chamber detector for Nuclear Instrumentation Signal Processor Drawer No. 1.
9/27/04 Refueled - removed core 04-45, loaded core 04-46.
Completed CP-29 (Calibration of the NMC RAK Stack Monitor)
UNSCHEDULED SHUTD OWNS Date No.
Type Cause 9/25/04 1174 Scram Ihstrumentation Signal Processor Drawer No. I Detector Cable failure On September 25, a reactor scram was automatically initiated when meter indications on Nuclear Instrumentation (NI) Signal Processor Drawer No. 1 pegged high, thus causing a reactor safety system trip. Troubleshooting efforts revealed a breakdown-of the signal cabling insulation near the fission chamber detector located in the reactor pool. This type of failure is typical of NI detector cabling that has been installed over two years. The fission detector and its associated cabling were replaced and the drawer was verified to be operable. The reactor was refueled and subsequently returned to 10 MW operation.
I Sep-04 OPERATION
SUMMARY
FOR MONTH OF University of Missour Research Reactor Center (MURR)
HOURS OPERATED THIS PERIOD TOTAL HOURS OPERATED, REACTOR HOURS OPERATED AT FULL POWER, THIS PERIOD TOTAL HOURS AT FULL POWER, REACTOR INTEGRATED POWER THIS PERIOD TOTAL INTEGRATED POWER, REACTOR Submitted by:
By L 1 645.97 1 261,213.05 l
644.10 L 257,879.42 1
268.46 l MWD i
101,650.69 l MWD MWD Custodian/Reactor Physicist
.1.0 6 t o SL Date: