Tennessee Valley Authority, Post Office Box 2000, Spring City, Tennessee 37381-2000 OCT 15 2004 U.S. Nuclear Regulatory Commission ATTN:
Document Control Desk Washington, D. C. 20555 Gentlemen:
In the Matter of
)
Docket No.50-390 Tennessee Valley Authority
)
WATTS BAR NUCLEAR PLANT (WBN) -
SEPTEMBER 2004 MONTHLY OPERATING REPORT Provided in the enclosure is the Monthly Operating Report for September 2004 as required by WBN Technical Specification Section 5.9.4.
There are no regulatory commitments in this submittal and should there be questions regarding this letter, please telephone me at (423) 365-1824.
Sincerely, P.
ace Manager, Site Licensing and Industry Affairs Enclosure Monthly Operating Report -
September 2004 cc:
See page 2 P,4ledwoecye paw
1 U.S. Nuclear Regulatory Commission Page 2 OCT 15 2004 cc (Enclosure):
NRC Resident Inspector Watts Bar Nuclear Plant 1260 Nuclear Plant Road Spring City, Tennessee 37381 Mr. R. J. Pascarelli, Project Manager U.S. Nuclear Regulatory Commission MS 07A15 One White Flint North 11555 Rockville Pike Rockville, Maryland 20852-2738 U.S. Nuclear Regulatory Commission Region II Sam Nunn Atlanta Federal Center 61 Forsyth St., SW, Suite 23T85 Atlanta, Georgia 30303
ENCLOSURE TENNESSEE VALLEY AUTHORITY WATTS BAR NUCLEAR PLANT (WBN)
MONTHLY OPERATING REPORT SEPTEMBER 2004 UNIT 1 DOCKET NUMBER 50-390 LICENSE NUMBER NPF-90 E-1
OPERATING DATA REPORT Docket No.
50-390 Unit Name:
WBN Unit 1 Date:
October 6, 2004 Completed By:
J. L. Kasten Telephone:
(423) 365-8022 Reporting Period:
September 2004
- 1. Design Electrical Rating (M\\Ne-Net):
1,155
- 2.
Maximum Dependable Capacity (MWe-Net):
1,121 Month
- 3.
Number of Hours Reactor was Critical 675
- 4.
Hours Generator On-Line 658
- 5.
Unit Reserve Shutdown Hours 0.0
- 6.
Net Electrical Energy Generated (M\\Nh) 708,344 Year-to-Date 6,495 6,471 0.0 7,318,938 Cumulative 67,258 66,923 0.0 74,334,622 E-2
I 111.
I
r -.
UNIT SHUTDOWNS DOCKET NO:
UNIT NAME:
DATE:
COMPLETED BY:
TELEPHONE:
50-390 WBN-1 October 6, 2004 J. L. Kasten (423) 365-8022 REPORT PERIOD: September 2004 N..
Date Type' Duratio Reason.2 Me.thod
- Licensee Syt em:
Component Ca e andCrrective At.
to (Ho..rs).......of.Event...od.....o...
Prvnt..Recurrence.............
Repo..rt...
N....
.v......
Dow
.of,.
..^..,
Iut~
J pe..,~~
~
~
Diratni: f-`M t-F.:
ns e e.:u.:omp:.on:en:
R t.
.ec o.::
109/19104 F
62.4 A
2 2004-02 AA DCC WBN Unit I was operating at approximately 100% powver when there wvas an inadvertent full insertion (drop) of four rods in Control Bank; B Group 2. This resulted from the failure of a Rod Control System powver cabinet phase control hoard. Due to the insertion of the rods, the reactor thermal power promptly dropped to approximately 67% and then stabilized at 85%. The reactor was manually tripped at approximately 04:56. The remaining control rods inserted properly and the Auxiliary Feedwater System actuated and functioned properly. The unit returned to service at 19:22 on September 21, 2004.
' F: Forced S: Scheduled 2 Reason:
A-Equipment Failure (Explain)
B-Maintenance or Test C-Refueling D-Regulatory Restriction E-Operator Training / License Examination F-Administrative G-Operational Error (Explain)
H-Other (Explain) 3 Method 1-Manual 2-Manual Trip/Scram 3-Automatic Trip/Scram 4-Continuation Outage 5-Other (Explain) 4 Instructions for Preparation of Data Entry sheets for Licensee Event Report (LER)
(NUREG - 1022)
Summary:
Unit I was manually tripped on September 19, 2004, and returned to service on September 21, 2004.
E-3