L-2004-219, Core Operating Limits Report

From kanterella
(Redirected from ML042940502)
Jump to navigation Jump to search
Core Operating Limits Report
ML042940502
Person / Time
Site: Turkey Point NextEra Energy icon.png
Issue date: 10/12/2004
From: Jones T
Florida Power & Light Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
L-2004-219
Download: ML042940502 (4)


Text

.

. Z-17 so, -I 9

I=PL OCT 1 2 2004 L-2004-219 10 CFR 50.36 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C. 20555 Re:

Turkey Point Unit 3 Docket No. 50-250 Core Operating Limits Report In accordance with Technical Specification 6.9.1.7, the attached Core Operating Limits Report is provided for Turkey Point Unit 3. These curves are applicable for Unit 3 Cycle 21.

Should there be any questions, please contact Walter Parker, Licensing Manager, at 305-246-6632.

Very truly yours, Terry 0. Jones Site Vice President Turkey Point Nuclear Plant OIH Attachment NRC Regulatory Issue Summary 2001-05 waived the requirements that multiple copies of documents be submitted to the NRC ciaoD I an FPL Group company

Attachment to L-2004-219 Page 1 of 3 CORE OPERATING LIMITS REPORT - UNIT 3 CYCLE 21 The Technical Specifications (TS) affected by this report are:

3.1.3.2 Analog Rod Position Indication System 3.1.3.6 Control Rod Insertion Limits 3.2.1 Axial Flux Difference (AED) 3.2.2 Heat Flux Hot Channel Factor - FQ(Z) 3.2.3 Nuclear Enthalpy Rise Hot Channel Factor - FAH The Control Rod Insertion Limits, AFD, FQ(Z), K(Z), and FAH have been developed using the NRC approved methodology specified in TS 6.9.1.7.

TS 3.1.3.2 Analog Rod Position Indication System The All Rods Out position for all Shutdown Banks and Control Banks is defined to be 230 steps withdrawn.

TS 3.1.3.6 Control Rod Insertion Limits The control rod banks shall be limited in physical insertion as shown on Figure 1 for All Rods Out = 230 steps withdrawn.

TS 3.2.1 Axial Flux Difference The AFD limits are provided on Figure 2.

TS 3.2.2 Heat Flux Hot Channel Factor - FQ(Z)

[FQ]

=2.50 K(Z) = 1.0 for 0 ft. < Z < 12 ft. where Z = core height.

TS 3.2.3 Nuclear Enthalpy Rise Hot Channel Factor 17RH1

- 1.70 PFAH =0.3

Attachment to L,2004-219 Page 2 of 3 10 01 0L 0.

A.

C.,

230 220 210 200 190 180 170 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0

Figure 1 Turkey Point Unit 3 - Cycle 21 Rod Insertion Limits vs Thermal Power ARO= 230 Steps Withdrawn, Overlap 102 Steps 105))

(01

-:~

lr0

-tt$

0 10 20 30 40 50 60 70 80 90 100 Percent Reactor Power

I'&

I Attachment to L-2004-219 Page 3 of 3 120 100

-0

-IJ IL I-LUJ LI-4-

C)

EL 80 60 40 Figure 2 Axial Flux Difference as a Function of Rated Thermal Power Turk e Point Unit 3 - C cle 21 UNAC CEPTABLE

.U ACCEPTA LE OP RATION OPERATIONI -.

(-30,50)

OPERATI BLE

(+21.50)

IOPERATION, 20 0

-50

-40

-30

-20

-10 0

10 20 30 40 50 Axial Flux Difference (%)