North Anna Unit 2 Updated Data Points Library Sheets Virginia Electric and Power Company (Dominion)

North Anna Unit 2

NORTH ANNA UNIT 2 UPDATED DATA POINT LIBRARY SHEETS

Page 60 of 93 PRINTED o~o712004 DATE:

REACTOR UNIT:

DATA FEEDER:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC:

GENERICICOND DESC:

ANALOGDIGITAL:

ENGR UNITSIDIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARMITRIP SETPOINTS:

STATION: North Anna UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE 01/21/2003 NA2 NIA MN FD FL 11A F2FW005C

' A SG MAIN FEEDWATER FLOW STM GEN A MAIN FEEDWATER FLOW A

MLBIHR 0-796.92" H20

-0.1000 5.OOOOO NIA NIA P

2 AVERAGE - SEE SYSTEM DESCRIPTION FEEDWTR HEATR DISCH UPSTRM OF STM GEN 1A VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NIA NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

N/A INSTRUMENT FAILURE MODE:

NIA TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC:

NIA Senses flow in main feedwater line to steam generator 1A. The average of the valid feed flow signals is used for this point. If all signals are valid, 2 signals will be used.

Page 61 of 93 PRINTED 09/07/2004 STATION: North Anna UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE DATE:

REACTOR UNIT:

DATA FEEDER:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC:

GENERICICOND DESC:

ANALOGDIGITAL:

ENGR UNITSDIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SETPOINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC:

01/21/2003 NA2 N/A MN FD R, 2/B F2FW006C

'B' SG MAIN FEEDWATER FLOW STM GEN B MAIN FEEDWATER FLOW A

MLB/HR 0-796.92" H20

-0.1000 5.00000 N/A N/A P

2 AVERAGE - SEE SYSTEM DESCRIPTION FEEDWTR HEATR DISCH UPSTRM OF STM GEN 1B VARIABLE N/A N/A N/A N/A Senses flow in main feedwater line to steam generator 1B. The average of the valid feed flow signals is used for this point. If all signals are valid, 2 signals will be used.

Page 62 of 93 PRINTED o~o712004 PWR DATE:

REACTOR UNIT:

DATA FEEDER:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC:

GENERICICOND DESC:

ANALOGDIGITAL:

ENGR UNITSDIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SETPOINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC:

STATION: North Anna UNIT: 2 DATA POINT LIBRARY REFERENCE FILE 0 112 112003 NA2 NIA MNFDFL3K F2FW007C

'C' SG MAIN FEEDWATER FLOW STM GEN C MAIN FEEDWATER FLOW A

MLBIHR 0-796.92" H20

-0.1000 5.00000 NIA NIA P

2 AVERAGE - SEE SYSTEM DESCRIPTION FEEDWTR HEATR DISCH UPSTRM OF STM GEN 1C VARIABLE NIA NIA NIA NIA Senses flow in main feedwater line to steam generator 1C. The average of the valid feed flow signals is used for this point. If all signals are valid, 2 signals will be used.

Page 73 of 93 PRINTED 09/07/2004 STATION: North Anna UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE DATE:

REACTOR UNIT:

DATA FEEDER:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC:

GENERIC/COND DESC:

AN ALOG/DIGIT AL:

ENGR UNITSIDIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED :

SENSOR LOCATIONS:

ALARMITRIP SETPOINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC:

0 1/2 112003 NA2 N/A SG BD RAD 1A R2RM220C

' A SG BLOWDOWN RAD MON STM GEN A BLOWDOWN RAD LEVEL A

CPM N/A 3.16200 1000000 N/A N/A P

1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT AUX BLDG ELEV 292 VARIABLE N/A NIA N/A N/A Continuously monitors radiation levels in the liquid phase of steam generator 2-RC-E-1 A blowdown. The sample is returned to the steam generator blowdown tank after being monitored.

Page 74 of 93 PRINTED o~o712004 DATE:

REACTOR UNIT:

DATA FEEDER:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC:

GENEIUCICOND DESC:

ANALOGDIGITAL:

ENGR UNITSDIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARMlTRIP SETPOINTS:

STATION: North Anna UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE 0112 112003 NA2 NIA SG BD RAD 2B R2RM221C

'B' SG BLOWDOWN RAD MON STM GEN B BLOWDOWN RAD LEVEL A

CPM NIA 3.16200 1000000 NIA NIA P

1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT AUX BLDG ELEV 292 VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NIA NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

NIA INSTRUMENT FAILURE MODE:

NIA TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC:

NIA Continuously monitors radiation levels in the liquid phase of steam generator 2-RC-E-1 B blowdown. The sample is returned to the steam generator blowdown tank after being monitored.

Page 75 of 93 PRINTED ow071mo4 STATION: North Anna UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE DATE:

REACTOR UNIT:

DATA FEEDER:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC:

GENERICICOND DESC:

ANALOGIDIGITAL:

ENGR UNITSIDIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARMITRIP SETPOINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC:

01/21/2003 NA2 NIA SG BD RAD 3C R2RM222C

'C' SG BLOWDOWN RAD MON STM GEN C BLOWDOWN RAD LEVEL A

CPM NIA 3.16200 1000000 NIA NIA P

1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT AUX BLDG ELEV 292 VARIABLE NIA NIA NIA NIA Continuously monitors radiation levels in the liquid phase of steam generator 2-RC-E-1C blowdown. The sample is returned to the steam generator blowdown tank after being monitored.

Page 76 of 93 DATE:

REACTOR UNIT:

DATA FEEDER:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC:

GENERIC/COND DESC:

ANALOG/DIGITAL:

ENGR UNITSDIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXI=

INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

A L W T R I P SETPOINTS:

STATION: North Anna UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NJA NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

N/A INSTRUMENT FAILURE MODE:

N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC:

0 1/2 112003 NA2 NJA SG LEVEL 1/A L2FwOO 1 c

' A STEAM GENERATOR LEVEL STEAM GENERATOR A WATER LEVEL A

PCT 1% = 1.44" H20 0.00000 100.000 UTUBES P

3 AVERAGE - SEE SYSTEM DESCRIPTION STM GEN-BOTTOM AT 533" & TOP AT 677" VARIABLE PRINTED 09/07/2004 WET Senses the water level in steam generator 1A. The valid narrow range signals are averaged (3 signals if all are valid). If none of the signals is valid, this point is marked invalid.

Page 78 of 93 DATE:

REACTOR UNIT:

DATA FEEDER:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC:

GENERICICONTI DESC:

ANALOGDIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

A L W T R I P SETPOINTS:

STATION: North Anna UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NIA NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

NIA INSTRUMENT FAILURE MODE:

NIA TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC:

01/21/2003 NA2 NIA SG LEVEL 2/B L2Fw002C

'B' STEAM GENERATOR LEVEL STEAM GENERATOR B WATER LEVEL A

PCT 1 % = 1.44" H20 0.00000 100.000 UTUBES P

3 AVERAGE - SEE SYSTEM DESCRIPTION STM GEN-BOTTOM AT 533" & TOP AT 677" VARIABLE PRINTED 091071mo4 WET Senses the water level in steam generator 1B. The valid narrow range signals are averaged ( 3 signals if all are valid). If none of the signals is valid, this point is marked invalid.

Page 80 of 93 DATE:

REACTOR UNIT:

DATA FEEDER:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC:

GENERIC/COND DESC:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SETPOINTS:

STATION: North Anna UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

N/A INSTRUMENT FAILURE MODE:

N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC:

0 1/2 1/2003 NA2 N/A SG LEVEL 3/C L2FW003C

'C' STEAM GENERATOR LEVEL STEAM GENERATOR C WATER LEVEL A

PCT 1% = 1.44" H20 0.00000 100.000 UTUBES P

3 AVERAGE - SEE SYSTEM DESCRIPTION STM GEN-BOTTOM AT 533" & TOP AT 677" VARIABLE PRINTED 09/07/#)04 WET Senses the water level in steam generator 1C. The valid narrow range signals are averaged (3 signals if all are valid). If none of the signals is valid, this point is marked invalid.

Page 82 of 93 DATE:

REACTOR UNIT:

DATA FEEDER:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC:

GENERICICOND DESC:

AN ALOGIDIGITAL:

ENGR UNITSIDIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARMITRIP SETPOINTS:

PRINTED 09/07/2004 STATION: North Anna UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE 0 112 112003 NA2 NIA SGPRESS 11A P2MS001C

'A' SG PRESSURE STEAM GENERATOR A PRESSURE A

PSIG NIA

-14.000 1400.00 NIA NIA P

3 AVERAGE - SEE SYSTEM DESCRIPTION OUTPUT OF STM GEN 2-RC-E-1A VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NIA Nl DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

NIA INSTRUMENT FAILURE MODE:

NIA TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC:

NIA Provides pressure of the steam which is on route from steam generator A to the main steam manifold. The valid wide range signals are averaged (3 signals if all are valid). If none of the signals is valid, this point is marked invalid.

Page 83 of 93 DATE:

REACTOR UNIT:

DATA FEEDER:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC:

GENERIC/COND DESC:

AN ALOG/DIGIT AL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALAWTRIP SETPOINTS:

STATION: North Anna UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE 01/21/2003 NA2 N/A SG PRESS 2/B P2MS002C

'B' SG PRESSURE STEAM GENERATOR B PRESSURE A

PSIG N/A

-14.000 1400.00 N/A N/A P

3 AVERAGE - SEE SYSTEM DESCRIPTION OUTPUT OF STM GEN 2-RC-E-1B VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

N/A INSTRUMENT FAILURE MODE:

N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC:

N/A Provides pressure of the steam which is on route from steam generator B to the main steam manifold. The valid wide range signals are averaged (3 signals if all are valid). If none of the signals is valid, this point is marked invalid.

Page 84 of 93 DATE:

REACTOR UNIT:

DATA FEEDER:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC:

GENERIC/COND DESC:

ANALOGDIGITAL:

ENGR UNITSIDIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARMITRIP SETPOINTS:

PRINTED 0~071mo4 STATION: North Anna UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE 01/21/2003 NA2 NIA SG PRESS 3/C P2MS003C

'C' SG PRESSURE STEAM GENERATOR C PRESSURE A

PSIG N/A

-14.000 1400.00 N/A NIA P

3 AVERAGE - SEE SYSTEM DESCRIPTION OUTPUT OF STM GEN 2-RC-E-1 C VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NIA NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

N/A INSTRUMENT FAILURE MODE:

N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC:

N/A Provides pressure of the steam which is on route from steam generator C to the main steam manifold. The valid wide range signals are averaged (3 signals if all are valid). If none of the signals is valid, this point is marked invalid.

Page 85 of 93 DATE:

REACTOR UNIT:

DATA FEEDER:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC:

GENERICICOND DESC:

ANALOGIDIGITAL:

ENGR UNITSIDIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRP SETPOINTS:

PRINTED 0~071mo4 STATION: North Anna UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE 10/21/2002 NA2 NIA STAB CLASS M3MMOO 1 C AVG SIGMA THETA AIR STABILITY AT REACTOR SITE A

DEGREES NIA 0.00000 50.0000 NIA NIA P

1 15 MINUTE RUNNING AVERAGE PRIMARY TOWER TRAILER VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NIA NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

NIA INSTRUMENT FAILURE MODE:

NIA TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC:

NIA Uses lower wind direction to find the standard deviation of the wind direction angle which is referred to as horizontal atmospheric stability. 15 minute running average is computed every 15 seconds.

Page 90 of 93 PRINTED 0~071mo4 DATE:

REACTOR UNIT:

DATA FEEDER:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC:

GENERICICOND DESC:

ANALOGJDIGITAL:

ENGR UNITSDIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALAMTRIP SETPOINTS:

STATION: North Anna UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE 1012 1/2002 NA2 N/A WIND DIR M3MM003C AVG LOWER WIND DIRECTION WIND DIR AT THE REACTOR SITE A

DEGREES N/A 0.00000 360.000 N/A N/A P

1 15 MINUTE RUNNING VECTOR AVERAGE 35' ON PRIMARY TOWER VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

N/A INSTRUMENT FAILURE MODE:

N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC:

N/A Senses the wind direction at 35'. 15 minute running vector average computed every 15 seconds.

Page 91 of 93 DATE:

REACTOR UNIT:

DATA FEEDER:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC:

GENERICICOND DESC:

ANALOG/DIGITAL:

ENGR UNITSDIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARMITRIP SETPOINTS:

PRINTED ow0712004 STATION: North Anna UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE 1012 112002 NA2 N/A WIND DIR M3MM004C AVG UPPER WIND DIRECTION WIND DIR AT THE REACTOR SITE A

DEGREES N/A 0.00000 3 60.000 N/A N/A P

1 15 MINUTE RUNNING VECTOR AVERAGE 150' ON PRIMARY TOWER VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

N/A INSTRUMENT FAILURE MODE:

N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC:

N/A Senses the wind direction at 150. 15 minute running vector average computed every 15 sewn ds.

REVISION

SUMMARY

Page 1 STATION: North Anna UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE CHANGE REPORT CHANGED POINT F2FWOOSC AT 10:47:27AM ON 01/21/2003. CHANGES WERE AS FOLLOWS:

DATE:

WAS :03/21/1991 IS

01/21/2003 PLANT SPEC POINT DESCRIPTION:

WAS :SGAMAINFEEDWATWFLOW PRINTED 071071mo4 IS

'A SG MAIN FEEDWATER FLOW

Page 2 STATION: North Anna UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE CHANGE REPORT CHANGED POINT F2FW006C AT 10:48:37AM ON 01/21/2003. CHANGES WERE AS FOLLOWS:

DATE:

WAS :03/21/1991 IS

01/21/2003 PLANT SPEC POINT DESCRIPTION:

WAS :SGBMAINEEDWATERFLOW PRINTED 07/07/2004 IS

'B' SG MAIN FEEDWATER FLOW

Page 3 STATION: North Anna UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE CHANGE REPORT CHANGED POINT F2FW007C A T 10:49: 1 IAM ON 01/21/2003. CHANGES WERE AS FOLLOWS:

DATE:

WAS :03/21/1991 IS

01/21/2003 PLANT SPEC POINT DESCRIPTION:

WAS :SGCMAINFEEDWATERFLOW PRINTED 07/07/2004 IS

'C' SG MAIN FEEDWATER FLOW

Page 4 STATION: North Anna UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE CHANGE REPORT CHANGED POINT LZFWOOIC AT 3:29:39PM ON 01/21/2003. CHANGES WERE AS FOLLOWS:

DATE:

WAS :05/17/1991 IS

01/21/2003 PLANT SPEC POINT DESCRIPTION:

WAS :STEAM GENERATOR A LEVEL PRINTED 07/07/2004 IS

'A' STEAM BNERATOR LEVEL

Page 5 STATION: North Anna UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE CHANGE REPORT CHANGED POINT L2FW002C AT 3:30:21PM ON 01/21/2003. CHANGES WERE AS FOLLOWS:

DATE:

WAS : 05/17/1991 IS

01/21/2003 PLANT SPEC POINT DESCRIPTION:

WAS :STEAM GENERATOR B LEVEL PRINTED 07/07/2004 IS

B' STEAM GENERATOR LEVEL

Page 6 STATION: North Anna UNIT: 2 CHANGE REPORT PWR DATA POINT LIBRARY REFERENCE FILE CHANGED POINT L2FW003C AT 3:30:50PM ON 01/21/2003. CHANGES WERE: AS FOLLOWS:

DATE:

WAS : 05/17/1991 IS

01/21/2003 PLANT SPEC POINT DESCRIPTION:

WAS : STEAM GENERATOR C LEVEL PRINTED 07/07/2004 IS

'C' STEAM GENERATOR LEVEL

Page 7 STATION: North Anna UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE CHANGE REPORT CHANGED POINT M3MMOOlC AT 2:27:53PM ON 10/21/2002. CHANGES WERE AS FOLLOWS:

DATE:

WAS : 01/15/1993 IS

1oi21/2oG2 ENGINEERING UNITS:

WAS :DEG PRINTED 07/07/2004 IS

DEGREES

Page 8 STATION: North Anna UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE CHANGE REPORT CHANGED POINT M3MM003C AT 2:28:42PM ON 10/21/2002. CHANGES WERE AS FOLLOWS:

DATE:

WAS : 01/15/1993 IS

10/21/2002 ENGINEERlNG UNITS:

WAS :DEG PRINTED 07/07/2004 IS

DEGREES

Page 9 STATION: North Anna UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE CHANGE REPORT CHANGED POINT M3MM004C AT 2:20:04PM ON 10/21/2002. CHANGES WERE AS FOLLOWS:

DATE:

WAS : 01/15/1993 IS

10/21/2002 ENGINEERING UNITS:

WAS :DEG PRINTED 07/07/2004 IS

DEGREES

Page 10 STATION: North Anna UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE CHANGE REPORT CHANGED POINT P2MS001C AT 10:56:10AM ON 01/21/2003. CHANGES WERE AS FOLLOWS:

DATE:

WAS : 03/21/1991 IS

01/21/2003 PLAN' SPEC POINT DESCRIPTION:

WAS :SGAPRESSURE PRINTED 07/07/2004 IS

'A' SGPRESSURE

Page 11 STATION: North Anna UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE CHANGE REPORT CHANGED POINT P2MS002C AT 12:07:48PM ON 01/21/2003.

CHANGES WERE AS FOLLOWS:

DATE:

WAS :03~111991 IS

OlL?li2003 PLANT SPEC POINT DESCRIPTION:

WAS :SGBPRESSURE PRINTED 07/07/2004 IS

'B' SG PRESSURE

Page 12 STATION: North Anna UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE CHANGE REPORT CHANGED POINT P2MS003C AT 12:11:12PM ON 01/21/2003. CHANGES WERE AS FOLLOWS:

DATE:

WAS :03/21/1991 IS

01/21/2003 PLANT SPEC POINT DESCRIPTION:

WAS :SGCPRESSURE PRINTED 07/07/2004 IS

'C' SG PRESSURE

Page 13 STATION: North Anna UNIT: 2 CHANGE REPORT PWR DATA POINT LIBRARY REFERENCE FILE CHANGED POINT R2RM220C AT 12:26:57PM ON 01/21/2003. CHANGES WEKE AS FOLLOWS:

DATE:

WAS :03/21/1991 IS

01/21/2003 PLAM SPEC POINT DESCRIPTION:

WAS : SGA BLWDN RAD MON PRINTED 07/07/2004 IS

'A' SGBLOWDOWN RAD MON

Page 14 STATION: North Anna UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE CHANGE REPORT CHANGED POINT R2RM22IC AT 12:27:51PM ON 01/21/2003. CHANGES WERE AS FOLLOWS:

DATE:

WAS :03/21/1991 IS

01/21/2003 PLANT SPEC POINT DESCRIPTION:

WAS :SGB BLWDNRADMON PRINTED o710712004 IS

'B' SG BLOWDOWN RAD MON

Page 15 STATION: North Anna UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE CHANGE REPORT CHANGED POINT R2RM222C AT 12.28:36PM ON 01/21/2003. CHANGES WERE AS FOLLOWS:

DATE:

WAS :03/21/1991 IS

01/21/2003 PLANT SPEC POINT DESCRIPTION:

WAS : S G C B L W D N W M O N PRINTED 07/07/2004 IS : 'C' SG BLOWDOWN RAD MON