September 10, 2004 Mr. Mark E. Warner, Site Vice President c/o James M. Peschel Seabrook Station PO Box 300 Seabrook, NH 03874
SUBJECT:
SEABROOK STATION, UNIT NO. 1 - REQUEST FOR ADDITIONAL INFORMATION REGARDING BULLETIN 2003-01 (TAC NO. MB9612)
Dear Mr. Warner:
By letter dated August 8, 2003, FPL Energy Seabrook, LLC (FPLE) responded to NRC Bulletin 2003-01, "Potential Impact of Debris Blockage on Emergency Sump Recirculation at Pressurized-Water Reactors." During the course of the review of FPLEs response, the Nuclear Regulatory Commission staff has determined that additional information, as delineated in the Enclosure, is needed to complete its review.
The request for additional information was discussed with your staff on September 1, 2004. A response date of October 29, 2004, was mutually agreeable.
If you have any questions, please call me at (301) 415-2855.
Sincerely,
/RA/
Scott P. Wall, Project Manager, Section 2 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-443
Enclosure:
Request for Additional Information cc w/encl: See next page
Seabrook Station, Unit No. 1 cc:
Mr. J. A. Stall Senior Vice President, Nuclear and Chief Nuclear Officer Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 33408-0420 Mr. Peter Brann Assistant Attorney General State House, Station #6 Augusta, ME 04333 Resident Inspector U.S. Nuclear Regulatory Commission Seabrook Nuclear Power Station P.O. Box 1149 Seabrook, NH 03874 Town of Exeter 10 Front Street Exeter, NH 03823 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Office of the Attorney General One Ashburton Place, 20th Floor Boston, MA 02108 Board of Selectmen Town of Amesbury Town Hall Amesbury, MA 01913 Ms. Deborah Bell Federal Emergency Management Agency Region I J.W. McCormack P.O. &
Courthouse Building, Room 401 Boston, MA 02109 Mr. Tom Crimmins Polestar Applied Technology One First Street, Suite 4 Los Altos, CA 94019 Mr. Stephen McGrail, Director ATTN: James Muckerheide Massachusetts Emergency Management Agency 400 Worcester Road Framingham, MA 01702-5399 Philip T. McLaughlin, Attorney General Steven M. Houran, Deputy Attorney General 33 Capitol Street Concord, NH 03301 Mr. Bruce Cheney, Director New Hampshire Office of Emergency Management State Office Park South 107 Pleasant Street Concord, NH 03301 Mr. Gene F. St. Pierre Station Director Seabrook Station FPL Energy Seabrook, LLC P.O. Box 300 Seabrook, NH 03874 Mr. M. S. Ross, Managing Attorney Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 33408-0420 Mr. Rajiv S. Kundalkar Vice President - Nuclear Engineering Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 33408-0420 James M. Peschel Regulatory Programs Manager Seabrook Station FPL Energy Seabrook, LLC PO Box 300 Seabrook, NH 03874
Seabrook Station, Unit No. 1 cc:
David Moore Vice President, Nuclear Operations Support Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 33408-0420 Marjan Mashhadi Senior Attorney Florida Power & Light Company 801 Pennsylvania Ave., NW Suite 220 Washington, DC 20004
Mr. Mark E. Warner, Site Vice President c/o James M. Peschel Seabrook Station PO Box 300 Seabrook, NH 03874
SUBJECT:
SEABROOK STATION, UNIT NO. 1 - REQUEST FOR ADDITIONAL INFORMATION REGARDING BULLETIN 2003-01 (TAC NO. MB9612)
Dear Mr. Warner:
By letter dated August 8, 2003, FPL Energy Seabrook, LLC (FPLE) responded to NRC Bulletin 2003-01, "Potential Impact of Debris Blockage on Emergency Sump Recirculation at Pressurized-Water Reactors." During the course of the review of FPLEs response, the Nuclear Regulatory Commission staff has determined that additional information, as delineated in the Enclosure, is needed to complete its review.
The request for additional information was discussed with your staff on September 1, 2004. A response date of October 29, 2004, was mutually agreeable.
If you have any questions, please call me at (301) 415-2855.
Sincerely,
/RA/
Scott P. Wall, Project Manager, Section 2 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-443
Enclosure:
Request for Additional Information cc w/encl: See next page DISTRIBUTION:
PUBLIC PDI-1 Reading DCollins SWall CRaynor AWang MKowal DSolorio JHannon LWhitney ACRS OGC BMcDermott, RGN-I GMatakas, RGN-I Accession Number: ML042470272 OFFICE PDI-2/PM PDI-1/SC(A)
NAME SWall DCollins DATE 9/7/04 9/8/04 OFFICIAL RECORD COPY
Enclosure REQUEST FOR ADDITIONAL INFORMATION REGARDING BULLETIN 2003-01, "POTENTIAL IMPACT OF DEBRIS BLOCKAGE ON EMERGENCY SUMP RECIRCULATION AT PRESSURIZED WATER REACTORS" SEABROOK STATION, UNIT NO. 1 DOCKET NO. 50-443 By letter dated August 8, 2003, FPL Energy Seabrook, LLC (FPLE or the licensee) responded to NRC Bulletin 2003-01, "Potential Impact of Debris Blockage on Emergency Sump Recirculation at Pressurized-Water Reactors," for Seabrook Station, Unit No. 1 (Seabrook).
During the course of review of the licensees bulletin response, the Nuclear Regulatory Commission staff has determined that it needs the following information:
1.
In response to Bulletin 2003-01, the licensee listed a number of existing indications that could indicate the onset of sump blockage, existing operator guidance documents relating to monitoring for sump blockage (e.g. pump motor current, pump flow rate, and pump discharge pressure), and enhanced training for operators and engineering support personnel on the issue of containment sump clogging. However, the licensee's response does not completely discuss the operator training to be implemented; in that, they do not discuss the existing response actions the operators are instructed to take in the event of sump clogging and loss of emergency core cooling systems (ECCS) recirculation capability. Provide a detailed description of how the current emergency operating procedures address sump clogging and a loss of ECCS recirculation capability.
2.
The Westinghouse Owners Group (WOG) has developed operational guidance in response to Bulletin 2003-01 for Westinghouse and Combustion Engineering type pressurized water reactors. For Seabrook, the licensees response stated that they will monitor the WOG activities and will consider implementation of any issued guidance.
Provide a discussion of the WOG-recommended compensatory measures that have been or will be implemented for the plants. Include a discussion of the evaluations or analyses performed to determine that these compensatory measures are acceptable for Seabrook, and provide technical justification for those WOG compensatory measures not being implemented. Also include a detailed discussion of the procedures being modified, the operator training being implemented, and the schedule for implementing these compensatory measures.
3.
NRC Bulletin 2003-01 provides possible interim compensatory measures licensees could consider to reduce risks associated with sump clogging. In addition to those compensatory measures listed in Bulletin 2003-01, licensees may also consider implementing unique or plant-specific compensatory measures, as applicable. Discuss any possible unique or plant-specific compensatory measures that were considered for implementation at Seabrook. Include a basis for rejecting any of these additional measures considered.