August 30, 2004 Mr. George Vanderheyden Vice President - Calvert Cliffs Nuclear Power Plant Constellation Generation Group, LLC 1650 Calvert Cliffs Parkway Lusby, Maryland 20657-4702

SUBJECT:

MID-CYCLE PERFORMANCE REVIEW AND INSPECTION PLAN - CALVERT CLIFFS NUCLEAR POWER PLANT

Dear Mr. Vanderheyden:

On August 4, 2004, the NRC completed its mid-cycle plant performance assessment of the Calvert Cliffs Nuclear Power Plant. The mid-cycle review for Calvert Cliffs involved the participation of all technical divisions in evaluating performance for the first half of the calendar year 2004 assessment cycle. The process included a review of performance indicators (PIs) for the most recent quarter and the inspection results over the previous twelve months. The purpose of this letter is to inform you of our assessment of your safety performance during this period and our plans for future inspections at your facility so that you will have the opportunity to prepare for these inspections and inform us of any planned inspections that may conflict with your plant activities. This performance review and enclosed inspection plan do not include physical protection information. A separate letter designated and marked as "Proprietary Information in accordance with 10 CFR 2.390(d)(1)" will include the physical protection review and resultant inspection plan.

Plant performance for the most recent quarter was within the Licensee Response Column of the NRCs Action Matrix, based on all inspection findings being classified as having very low safety significance (Green) and all PIs indicating performance at a level requiring no additional NRC oversight (Green). Therefore, we plan to conduct only reactor oversight process (ROP) baseline inspections at your facility through March 31, 2006. However, the significance of a Unit 2 finding regarding a relay failure that caused the steam dump valves to fail open following a January 23, 2004, trip is still under review as part of the Significance Determination Process (NRC Inspection Report 2004-008).

The enclosed inspection plan details the inspections, less those related to physical protection, scheduled through March 31, 2006. The inspection plan is provided to minimize the resource impact on your staff and to allow for scheduling conflicts and personnel availability to be resolved in advance of inspector arrival onsite. Routine resident inspections are not listed due to their ongoing and continuous nature. The inspections in the last twelve months of the inspection plan are tentative and may be revised at the end-of-cycle review meeting.

In accordance with 10 CFR 2.390 of the NRCs Rules of Practice, a copy of this letter and its enclosure will be made available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRCs document system

Mr. George Vanderheyden 2

(ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.govreading-rm/adams.html (Public Electronic Reading Room).

If circumstances arise which cause us to change the inspection plan, we will contact you to discuss the change as soon as possible. Please contact me at (610) 337-5186 with any questions you may have regarding this letter or the inspection plan.

Sincerely,

/RA/

James M. Trapp, Chief Projects Branch 1 Division of Reactor Projects Docket Nos. 50-317, 50-318 License Nos. DPR-53, DPR-69

Enclosure:

Calvert Cliffs Inspection/Activity Plan cc w/encl:

M. J. Wallace, President, Constellation Generation J. M. Heffley, Senior Vice President and Chief Nuclear Officer President, Calvert County Board of Commissioners J. M. Petro, Esquire, Constellation Energy Group, Inc.

J. E. Silberg, Esquire, Shaw, Pittman, Potts and Trowbridge Director, Nuclear Regulatory Matters R. McLean, Manager, Nuclear Programs K. Burger, Esquire, Maryland People's Counsel State of Maryland (2)

Institute of Nuclear Power Operations (INPO)

Mr. George Vanderheyden 3

Distribution w/encl:

(via E-mail)

S. Collins, RA J. Wiggins, DRA C. Miller, RI EDO Coordinator R. Laufer, NRR R. Guzman, PM, NRR R. Clark, PM, NRR P. Tam, PM, NRR (Backup)

J. Trapp, DRP N. Perry, DRP M. Giles, DRP, Senior Resident Inspector J. OHara, DRP - Resident Inspector C. Newgent - Resident OA D. Screnci, PAO N. Sheehan, PAO DRS Director DRS Deputy Director DRS Branch Chiefs RidsNrrDipmlipb Region I Docket Room (with concurrences)

DOCUMENT NAME: G:\\DRP\\BRANCH1\\BRANCH1\\2004 ROP 5 Mid-Cycle Review\\2004 Mid-Cycle Letters\\Calvert Cliffs 2004 Mid-Cycle Letter.wpd After declaring this document An Official Agency Record it will be released to the Public.

To receive a copy of this document, indicate in the box: "C" = Copy without attachment/enclosure "E" = Copy with attachment/enclosure "N" = No copy OFFICE RI/DRP N RI/DRP C

NAME NPerry/NSP JTrapp/JMT DATE 08/25/04 08/30/04 08/ /04 08/ /04 OFFICIAL RECORD COPY

Calvert Cliffs Inspection / Activity Plan 07/01/2004 - 03/31/2006 Inspection Type Inspection Activity Planned Dates Start End No. of Staff on Site Title Unit Number Page 1 of 2 08/30/2004 10:33:08 Report 22 1

71114

- EP PROGRAM INSPECT & PI VERIF Baseline Inspections 07/12/2004 07/16/2004 Alert and Notification System Testing IP 7111402 1, 2 Baseline Inspections 07/12/2004 07/16/2004 Emergency Response Organization Augmentation Testing IP 7111403 1, 2 Baseline Inspections 07/12/2004 07/16/2004 Emergency Action Level and Emergency Plan Changes IP 7111404 1, 2 Baseline Inspections 07/12/2004 07/16/2004 Correction of Emergency Preparedness Weaknesses and Deficiencies IP 7111405 1, 2 4

7111401

- EXERCISE EVALUATION Baseline Inspections 10/04/2004 10/08/2004 Exercise Evaluation IP 7111401 1, 2 1

7111112B

- MAINTENANCE RULE Baseline Inspections 12/13/2004 12/17/2004 Maintenance Effectiveness IP 7111112B 1, 2 1

71121

- OCC RAD SAFETY Baseline Inspections 12/13/2004 12/17/2004 Access Control to Radiologically Significant Areas IP 7112101 1, 2 Baseline Inspections 12/13/2004 12/17/2004 ALARA Planning and Controls IP 7112102 1, 2 Baseline Inspections 12/13/2004 12/17/2004 Radiation Monitoring Instrumentation and Protective Equipment IP 7112103 1, 2 Baseline Inspections 12/13/2004 12/17/2004 Performance Indicator Verification IP 71151 1, 2 1

7112203

- PUB RAD SAFETY - REMP Baseline Inspections 12/13/2004 12/17/2004 Radiological Environmental Monitoring Program IP 7112203 1, 2 1

71121

- OCC RAD SAFETY Baseline Inspections 01/31/2005 02/04/2005 Access Control to Radiologically Significant Areas IP 7112101 1, 2 Baseline Inspections 01/31/2005 02/04/2005 ALARA Planning and Controls IP 7112102 1, 2 Baseline Inspections 01/31/2005 02/04/2005 Radiation Monitoring Instrumentation and Protective Equipment IP 7112103 1, 2 Baseline Inspections 01/31/2005 02/04/2005 Performance Indicator Verification IP 71151 1, 2 1

71121

- OCC RAD SAFETY Baseline Inspections 02/21/2005 02/25/2005 Access Control to Radiologically Significant Areas IP 7112101 1, 2 Baseline Inspections 02/21/2005 02/25/2005 ALARA Planning and Controls IP 7112102 1, 2 Baseline Inspections 02/21/2005 02/25/2005 Radiation Monitoring Instrumentation and Protective Equipment IP 7112103 1, 2 Baseline Inspections 02/21/2005 02/25/2005 Performance Indicator Verification IP 71151 1, 2 3

7111108P

- INSERVICE INSPECTION - U2 Safety Issues 02/25/2005 02/27/2005 Reactor Pressure Vessel Head and Vessel Head Penetration Nozzles (NRC Bulletin 2002-02)

IP 2515/150 2

Baseline Inspections 02/28/2005 03/04/2005 Inservice Inspection Activities - PWR IP 7111108P 2

1 7112201

- PUB RAD SAFETY - RETS Baseline Inspections 07/25/2005 07/29/2005 Radioactive Gaseous and Liquid Effluent Treatment and Monitoring Systems IP 7112201 1, 2 1

7111401

- EXERCISE EVALUATION & EP PI VERIFICATION Baseline Inspections 09/26/2005 09/30/2005 Exercise Evaluation IP 7111401 1, 2 Baseline Inspections 09/26/2005 09/30/2005 Performance Indicator Verification IP 71151 1, 2 This report does not include INPO and OUTAGE activities.

This report shows only on-site and announced inspection procedures.

Calvert Cliffs Inspection / Activity Plan 07/01/2004 - 03/31/2006 Inspection Type Inspection Activity Planned Dates Start End No. of Staff on Site Title Unit Number Page 2 of 2 08/30/2004 10:33:08 Report 22 1

71121

- OCC RAD SAFETY Baseline Inspections 10/10/2005 10/14/2005 Access Control to Radiologically Significant Areas IP 7112101 1, 2 Baseline Inspections 10/10/2005 10/14/2005 ALARA Planning and Controls IP 7112102 1, 2 Baseline Inspections 10/10/2005 10/14/2005 Radiation Monitoring Instrumentation and Protective Equipment IP 7112103 1, 2 Baseline Inspections 10/10/2005 10/14/2005 Performance Indicator Verification IP 71151 1, 2 4

71152B

- PROBLEM IDENTIFICATION AND RESOLUTION Baseline Inspections 10/31/2005 11/04/2005 Identification and Resolution of Problems IP 71152B 1, 2 Baseline Inspections 11/14/2005 11/18/2005 Identification and Resolution of Problems IP 71152B 1, 2 1

7112202

- PUB RAD SAFETY - RADWASTE Baseline Inspections 10/24/2005 10/28/2005 Radioactive Material Processing and Transportation IP 7112202 1, 2 2

7111111B

- LO REQUAL PROGRAM INSPECTION Baseline Inspections 12/05/2005 12/09/2005 Licensed Operator Requalification Program IP 7111111B 1, 2 7

SSDI

- SSDI Baseline Inspections 01/09/2006 01/13/2006 Safety System Design and Performance Capability IP 7111121 1, 2 Baseline Inspections 01/23/2006 01/27/2006 Safety System Design and Performance Capability IP 7111121 1, 2 3

MODS

- MODS & 50.59 Baseline Inspections 01/23/2006 01/27/2006 Evaluation of Changes, Tests, or Experiments IP 7111102 1, 2 Baseline Inspections 01/23/2006 01/27/2006 Permanent Plant Modifications IP 7111117B 1, 2 1

71121

- OCC RADIATION SAFETY Baseline Inspections 01/30/2006 02/03/2006 Access Control to Radiologically Significant Areas IP 7112101 1, 2 Baseline Inspections 01/30/2006 02/03/2006 ALARA Planning and Controls IP 7112102 1, 2 Baseline Inspections 01/30/2006 02/03/2006 Radiation Monitoring Instrumentation and Protective Equipment IP 7112103 1, 2 Baseline Inspections 01/30/2006 02/03/2006 Performance Indicator Verification IP 71151 1, 2 1

3/16+EXM

- OPERATOR LICENSING INITIAL EXAM Not Applicable 02/06/2006 02/10/2006 CALVERT CLIFFS INITIAL EXAM (3/06)

U01585 1

Not Applicable 03/06/2006 03/10/2006 CALVERT CLIFFS INITIAL EXAM (3/06)

U01585 1

2 HEATSINK

- HEAT SINK Baseline Inspections 02/20/2006 02/24/2006 Heat Sink Performance IP 7111107B 1, 2 This report does not include INPO and OUTAGE activities.

This report shows only on-site and announced inspection procedures.