July 2004 Monthly Operating Report for Wolf Creek Generating Station
ML042320237
Person / Time
Site: Wolf Creek 
Issue date: 08/11/2004
From: Moles K
Wolf Creek
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
GL-97-002, RA 04-0098
Download: ML042320237 (3)


Text

W0LF CREEK NUCLEAR OPERATING CORPORATION Kevin J. Moles Manager Regulatory Affairs AUG 11, 2004 RA 04-0098 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Subject Docket No. 50-482: July 2004 Monthly Operating Report Gentlemen:

Attached to this letter Is the July 2004, Monthly Operating Report for the Wolf Creek Generating Station. This submittal Is being made in accordance with the requirements of Wolf Creek Generating Station Technical Specification 5.6.4, fMonthly Operating Reports."

This submittal follows the guidance of Generic Letter 97-02, *Revised Contents of the Monthly Operating Report.

If you have any questions regarding this report, please contact me at (620) 364-4126, or Ms. Diane Hooper at (620) 3644041.

Very truly yours, Kevin J. Moles KJM/rIg Attachment cc:

J. N. Donohew (NRC), w/a D. N. Graves (NRC), w/a B. S. Mallett (NRC), wla Senior Resident Inspector (NRC), w/a P.O. BCx 411 / Burlington, KS 66839 / Phone: (620) 364-8831 An Equal Opportunity Emplyer M/F/HCNVET 1

i" ;! '-

1

v I '

':1,.

1.:

Attachment to RA 04-0098 Page 1 of 2 r

iOPERATING DATA REPORT Report Number 233 DOCKET NO.:

UNIT NAME:

DATE:

COMPLETED BY:

TELEPHONE:

50-482 Wolf Creek Generating Station August 11, 2004 D. M. Hooper (620) 364-4041 REPORT MONTH: July 2004 l17A. Design Electrical Rating (MWe - Net):

l 1170 1

l 2.

l Maximum Dependable Capacity(MWe - Net):

l 1166 This Month Year to Date Cumulative

3.

Number of Hours Reactor Critical:

l 744.00 I

5,055.73 l

142,832.40

4.

Number of Hours Generator On-Line:

j 744.00 5,043.50 141,585.35

5.

Unit Reserve Shutdown Hours:

0.00 0.00 339.80

6.

Net Electrical Energy Generated (MWH) 837,005.00 5,904,966.00 160,886,127.00 Wolf Creek Generating Station Monthly Operating Report July 2004 Page I of 2

Attachment to RA 04-0098 Page 2 of 2 UNIT SHUTDOWN AND POWER REDUCTIONS DOCKET NO.:

UNIT NAME:

DATE:

COMPLETED BY:

TELEPHONE:

50-482 Wolf Creek Generating Station August 11, 2004 D. M. Hooper (620) 364-4041 Type METHOD OF SHUTTING F: FORCED DURATION REASON DOWN THE REACTOR CORRECTIVE ACTIONS/COMMENTS No.

Date S: SCHEDULED (Hours)

(1)

(2)

N/A N/A N/A N/A N/A N/A N/A

SUMMARY

The unit operated in Mode 1, at or near 100% power, from July 1, 2004, until July 30, 2004.

to <30% due to condenser tube leak.

On July 30, 2004, power reduction (1) REASON:

A EQUIPMENT FAILURE (EXPLAIN)

B: MAINTENANCE OR TEST C: REFUELING D: REGULATORY RESTRICTiON E: OPERATOR TRAINING AND LICENSE EXAMINATION F: ADMINISTRATIVE G: OPERATIONAL ERROR (EXPLAIN)

H: OTHER (EXPLAIN)

(2) METHOD: 1. MANUAL

2. MANUAL SCRAM
3. AUTOMATIC SCRAM
4. CONTINUATION
5. OTHER Wolf Creek Generating Station Monthly Operating Report July 2004 Page 2 of 2 9,