University of Marylands Response to the Request for Additional Information Re Environmental Report for Training Reactor
ML042240227
Person / Time
Site: University of Maryland
(R-070)
Issue date: 08/04/2004
From: Al-Sheikhly M
Univ of Maryland
To: Alexander Adams
Office of Nuclear Reactor Regulation
References
Download: ML042240227 (3)


Text

United States Nuclear Regulatory Commission One White Flint North MS 12G13 11555 Rockville Pike Rockville, Maryland 20852-2738 ATTN: ALEXANDER ADAMS, JR August 4, 2004 Enclosed please find the University of Maryland's response to the request for additional information as it pertains to the Environmental Report for the Maryland University Training Reactor.

I declare under penalty of perjury that the foregoing is true and correct.

Executed on August 4, 2004

[Signature ohamad Al-eIkhly, Director University of Maryland Training Reactor License Number R-70, Docket number 50-166 AO

I ENVIRONMENTAL REPORT

72.Section V of the 1999-2000 Annual Operating Report states that continuous monitoring for the year was accomplished using fixed-mounted film badges throughout the interior of the reactor building. Facility Technical Specification 3.6.4 specifies that the campus radiation safety organization maintain an environmental monitor at the site boundary as well. Explain how compliance is demonstrated, and if any abnormal radiation levels were ever detected.

Response

These environmental monitors are mounted on the east and west exterior walls of the building and have been evaluated for more than a decade. A synopsis of the readings is shown in the following table for the period of January 15, 1999 to present. The results are gross readings and are not background adjusted.

Environmental Monitoring Maryland University Training Reactor 2004 Time Period

  1. 2 Time Period
  1. 7 Dose Dose Start End Location mr Start End Location mr 1/2512004 4/25/2004 West Wall 21.0 1/25/2004 4/25/2004 East Wall 23.0 West Wall East Wall West Wall East Wall West Wall East Wall Annual 21.0 Annual 23.0 2003 Time Period
  1. 2 Time Period
  1. 7 Dose Dose Start End Location mr Start End Location mr 1/25/2003 4/25/2003 West Wall 24.0 1/25/2003 4/25/2003 East Wall 25.0 4/25/2003 7/25/2003 West Wall 28.0 4/25/2003 7/25/2003 East Wall 26.0 7125/2003 10/25/2003 West Wall 28.0 7/25/2003 10/25/2003 East Wall 29.0 10/25/2003 1/15/2002 West Wall 32.0 10/25/2003 1/15/2002 East Wall 34.0 Annual 112.0 Annual 114.0 2002 Time Period
  1. 2 lime Period
  1. 7 Dose Dose Start End Location mr Start End Location mr 1/15/2002 4/15/2002 West Wall 37.8 1/15/2002 4/15/2002 East Wall 45.1 4/15/2002 7/15/2002 West Wall 12.7 4/15/2002 7/15/2002 East Wall 13.4 7/15/2002 10/25/2002 West Wall 27.1 7/15/2002 10/25/2002 East Wall 27.5 10/25/2002 1/15/2001 West Wall 30.4 10/25/2002 1/15/2001 East Wall 30.4 Annual 108.0 Annual 116.4 2001 Time Period
  1. 2 Time Period
  1. 7 Start End Location 1/15/2001 4/15/2001 West Wall 4/15/2001 7/15/2001 West Wall 7/15/2001 10/25/2001 West Wall Dose mr 29.7 26.5 26.0 Start End Location 1/15/2001 4/15/2001 East Wall 4/15/2001 7/15/2001 East Wall 7/15/2001 10/25/2001 East Wall Dose mr 29.1 29.0 27.3

10/25/2001 1/15/2000 WestWall 27.4 10/2512001 1/15/2000 East Wall 30.9 Annual 109.6 Annual 85.4 2000 Time Period

  1. 2 Time Period
  1. 7 Dose Dose Start End Location mr Start End Location mr 1/15/2000 4/15/2000 West Wall 19.6 1/15/2000 4/15/2000 East Wall 21.4 4/15/2000 7/15/2000 West Wall 24.1 4/15/2000 7/15/2000 East Wall 25.5 7/15/2000 10/25/2000 West Wall 24.8 7/15/2000 10/25/2000 East Wall 25.5 10/25/2000 1/15/1999 West Wall 28.0 10/25/2000 1/15/1999 East Wall 34.3 Annual 96.5 Annual 106.7 1999 Time Period
  1. 2 Time Period
  1. 7 Dose Dose Start End Location mr Start End Location mr 1/15/1999 4/15/1999 West Wall 12.2 1/15/1999 4/15/1999 East Wall 12.3 4/15/1999 7/15/1999 West Wall 23.3 4/15/1999 7/15/1999 East Wall 15.7 7/15/1999 10/15/1999 West Wall 20.2 7/15/1999 10/15/1999 East Wall 25.0 10/15/1999 1/15/1998 West Wall 32.8 10/15/1999 1/15/1998 East Wall 34.5 Annual 88.5 Annual 87.5 These results are typical of what is observed during a review of all environmental monitors. Considering the naturally occurring background, these results are statistically indistinguishable from other areas that are not in the vicinity of a nuclear facility. All results of the area monitors are delivered to the University of Maryland Radiation Safety Office where they are reviewed and approved by the Radiation Safety Officer.

Any elevated readings will be brought to the attention of the Reactor Director and if warranted, to the Radiation and Reactor Safety Committees.

73. Discuss actual releases of airborne, liquid and solid waste from the facility for the past 10 years and if these trends are expected to continue in the future.

Response

The manufacture and release of liquid and solid waste is typically limited to one cubic foot of low level resin from the ion exchange column and one sock filter per year. The levels are typically not more than three times the background levels of the area. The sock filter is approximately 500 grams and consists of a fibrous synthetic tube that is closed on one end. This is the coarse filter for the primary coolant system as described in the FSAR.

There has been no liquid waste released other than the overflow from the vessel overflow. This waste was surveyed by the Radiation Safety Office and approved for discharge into the environment. The sump is emptied approximately every three to five years with a total volume of approximately 50 gallons.

This pattern of minimal release is expected to continue as the MUTR is predominantly a training facility with occasional NAA that is typically performed with extremely small quantities of samples which are held for decay and not disposed of as radioactive waste.