Maitri Banerjee - Re: Quad 2 Recic Flaws - Code Case Repair Page 11l From:
Maitri Banerjee To:
Thomas.Roddey~exeloncorp.com Date:
3/16/04 5:31 PM
Subject:
Re: Quad 2 Recic Flaws - Code Case Repair Please provide the following information related to the subject:
- 1. A drawing showing the flaws and the repairs;
- 2. Are flaws of consideration in Class 1 piping?
- 3. Does the repair consist of a full structural overlay or a patch repair.
- 4. Please confirm the Code Case that is used in entirety for the repair, N-504-1, or N-504-2.
- 5. Please indicate what Code was used for the flaw evaluation and what the post repair and successive inspection requirements are.
Please let me know if we need a phone call to discuss the above.
Thank you.
Maitri Banerjee, PE Sr. Project Manager NRR CC:
George Georgiev; Lawrence Rossbach
+ C:.\\W1ND0WS\\TEMP\\GWJ00001.TMP Page 1 I C:\\WINDOWS\\TEMP\\GW}QOOO1.TMP Page 1 ii Mail Envelope Properties (40578045.B13: 8: 21450)
Subject:
Creation Date:
From:
Created By:
Re: Quad 2 Recic Flaws - Code Case Repair 3/16/04 5:31PM Maitri Banerjee MXB @nrc.gov Recipients exeloncorp.com Thomas.Roddey (Thomas.Roddey@exeloncorp.c Action Transferred Date & Time 03/16/04 05:32PM nrc.gov owf2_po.OWFN_DO GBG CC (George Georgiev) nrc.gov owf4-po.OWFNDO LWR CC (Lawrence Rossbach)
Post Office owf2_po.OWFN_DO owf4-po.OWFNDO Delivered Opened Delivered Opened Delivered 03/16/04 05:32PM 03/16/04 05:3 1PM 03/16/04 05:32PM 03/18/04 09:03AM 03/16/04 05:3 1PM 03/17/04 10:41AM Route exeloncorp.com nrc.gov nrc.gov Files MESSAGE Options Auto Delete:
Expiration Date:
Notify Recipients:
Priority:
Reply Requested:
Return Notification:
Concealed
Subject:
Security:
To Be Delivered:
Status Tracking:
Size 1664 Date & Time 03/16/04 05:3 1PM No None Yes Standard No None No Standard Immediate Delivered & Opened