Message' Page-i of 1 iMessage PageA of I Sienel, Beth From:
Pichette, Ann Sent:
Wednesday, November 12, 2003 12:48 PM To:
'lereventsDinpo.org'; 'rbelval@velco.com'; 'gparker~velco.com'; 'rivest gmpvt.com';
'martin @ gmpvt.com'; 'kvedar@ gmpvt.com'; 'dutton @ gmpvt.com'; 'brown @gmpvt.com';
'william.sherman@state.vt.us'; 'BOliveira@AmNuclns.com'; 'barbaralewisl @platts.com';
'bamelan~cvps.com'; Kilburn, Bobbi; Thayer, Jay; Bronson, Kevin; Williams, Rob; Cosgrove, Brian; McElwee, David; Finn, Brian; Porter, Brad; Wanczyk, Robert; Yialiades, Theresa; Sandstrum, Sally; Jefferson, Stan; Mannai, David; Wallin, Greg; Rondeau, Nancy; Skibniowsky, Steve; Sienel, Beth; Pelton, David
Subject:
Entergy Vermont Yankee Nuclear Power Station MSR October 2003 Attached please find the Entergy Vermont Yankee Nuclear Power Station Monthly Statistical Report for October 2003.
If you have any questions please contact me.
Ann M. Pichette Controlled Document Specialist Technical Support Department 802-451-3094 MC 1220 r,1 II MAA
C-E I
t Entg Entergy Nuclear Northeast Entergy Nuclear Operatfons, Inc.
Vermont Yankee 322 Governor Hunt Rd.
P.O. Box 157 Vernon, VT 05354 Tel 802-257-7711 November 10, 2003 BVY-03-99 United States Nuclear Regulatory Commission ATIN: Document Control Desk Washington, D.C. 20555
Reference:
(a) License No. DPR-28 (Docket No. 50-271)
In accordance with section 6.6J3 of the Vermont Yankee Technical Specifications, submitted herewith is the Monthly Statistical Report for the Vermont Yankee Nuclear Power Station for the month of October. 2003.
- Sicrel, S7 pd Kevin H. Bronson General Manager, Plant Operations cc: USNRC Region I Administrator USNRC Resident Inspector USNRC Project Manager
I VERMONT YANKEE NUCLEAR POWER STATION MONTHLY STATISTICAL REPORT 03-10 FOR TIE MONTH OF OCTOBER 2003
OPERATING DATA REPORT DOCKETNO.50-271 DATE 031110 COMPLETED BY G.A. WALLIN TELEPHONE (802)258-5414 OPERATING STATUS
- 1. Unit Name:
Vermont Yankee
- 2. Reporting Period:
October
- 3. Licensed Thermal Power(MWt):1593
- 4. Nameplate Rating(Gross MWe): 540
- 5. Design Electrical Rating(Net MWe):
522
- 6. Maximum Dependable Capacity(Gr6ss MWe):
'535 -
- 7. Maximum Dependable Capacity(Net MWe):
510
- 8. If changes, occur in capacity ratings(Items Number 3 through 7) since last report, give reasons:
- 9. Power level to which restricted, if any(Net MWe):
N/A
- 10. Reasons for restrictions, if any:
N/A This Month Yr-to-Date Cumulative
- 11. Hours-in Reporting Period 745.00 7296.00 273457.80
- 12. Number Of Hours Reactor was Critical 699.22 7188.39 230337.22
- 13. Reactor Reserve Shutdown Hours 0.00 0.00 0.00
- 14. Hours Generator On-Line 683.08 7148.91 226662.69
- 15. Unit Reserve Shutdown Hours 0.00 0.00 0.00
- 16. Gross Thermal Energy Generated(MWH) 1075397.90 11275747.63 343656164.44
- 17. Gross Electrical Energy Generated(MWH) 369409.00 3852734.00 115433664.00
- 18. Net Electrical Energy Generated(HQIH) 353639.00 3676919.00 109859278.00
- 19. Unit Service Factor 91.69 97.98 82.89
- 20. Unit Availability Factor 91.69 97.98 82.89
- 21. Unit Capacity Factor(Using MDC Net) 93.08 98.82 79.45
- 22. Unit Capacity Factor(Using DER Net) 90.94 96.55 77.83
- 23. Unit Forced Outage Rate 8.31 1.70 3.87
- 24. Shutdowns scheduled over next 6 months(Type, Date, and Duration of Each:
N/A
- 25. If shut down at end of report period, estimated date of startup: N/A
- 26. Units In Test Status(prior to commercial operation): N/A Forecast Achieved INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION VYDPF 0411.01 (Sample)
DP 0411 Rev. 8 Page 1 of 1 RT No. 13.F01.19F
AVERAGE DAILY UNIT POWER LEVEL DOCKET NO. 50-271 UNIT Vermont Yankee DATE 031110 COMPLETED BY G.A. WALLIN TELEPHONE (802)258-5414 MONTH October DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)
(MWe-Net)
- 1.
0
- 17.
527
- 2.
0
- 18.
527 3
208
- 19.
527
- 4.
466
- 20.
527
- 5.
498
- 21.
527
- 6.
523
- 22.
527
- 7.
525
- 23.
528
- 8.
526
- 24.
527
- 9.
524
- 25.
527
- 10.
521
- 26.
528
- 11.
519
- 27.
528
- 12.
518
- 28.
527
- 13.
521
- 29.
526
- 14.
523
- 30.
523
- 15.
527
- 31.
527
- 16.
528
- 25 hour day INSTRUCTIONS:
On this format; list the average daily unit power level in MWE-Net for each day in the reporting month.
Compute to the nearest whole megawatt.
VYDPF 0411.02 (Sample)
DP 0411 Rev. 8 Page 1 of 1 RT No. 13.F01.18V
UNIT SHUTDOWNS AND POWER REDUCTIONS REPORT MONTH OCTOBER DOCKET NO UNIT NAME DATE COMPLETED BY TELEPHONE 50-271 Vermont Yankee 031110 G.A. Wallin (802)258-5414 1
2 3
4 5
Cause and Corrective Action to Prevent No.
Date Type Duration Reason Method of License System Componeit Recurrence.
Shutting Event Code Code (hours)
Down Report #
Reactor 03-11 030929 F
61.92 A
1 N/A CB VALVEX Manual shutdown for ABN Manual recirculation pump seal (cont) replacement.
1 F: Forced S: Scheduled 2 Reason:
A-Equipment Failure (Explain)
B-Maintenance or Test C-Refueling D-Regulatory Restriction E-Operator Training and License Examination F-Administrative G-Operational Error (Explain)
H-(Explain) -
3 Method:
4 1 -
Manual 2 -
Manual Scram 3 - Automatic Scram 4 -
Other (Explain)
Exhibit G-Instructions for Preparation of Data Entry Sheets for License Event,Report (LER) File (NUREd 0161) 5 Exhibit I -
Same Source VYDPF 041i.03 DP 0411 Rev. 8 Page 1 of 1
DOCKET NO.
DATE COMPLETED BY TELEPHONE 50-271 031110 G.A. WALLIN (802)258-5414 REPORT MONTH October SUMIARY OF OPERATING EXPERIENCES Highlights Vermont Yankee operated at 90.6% of rated thermal power for the month.
Gross electrical generation was 369,409 NMHe or 90.8% design electrical capacity.
Operating Sunkrary.
-t The following is a chronological description of plant operations including other pertinent items of interest for the month:
At the beginning of the reporting period the plant was operating at 00.0%
of rated thermal power.
031002 At 2147 hours0.0248 days <br />0.596 hours <br />0.00355 weeks <br />8.169335e-4 months <br />, the reactor was critical following "BE recirculation pump seal replacement.
(See Unit Shutdowns and Power Reductions) 031003 At 1355 hours0.0157 days <br />0.376 hours <br />0.00224 weeks <br />5.155775e-4 months <br />, the turbine-generator was phased to the grid.
031003 At 1838 hours0.0213 days <br />0.511 hours <br />0.00304 weeks <br />6.99359e-4 months <br />, began a return to full power.
At the end of the reporting period the plant was operating rated thermal power.
at 99.9% of VYDPF 0411.04 (Sample)
DP 0411 Rev. 8 Page 1 of 1 RT No. 13.F01.18X