Text
M\\- ~1 Exelons.
Exelon Nuclear Peach Bottom Atomic Power Station 1848 Lay Road Delta, PA 17314-9032 Telephone 717.456.7014 www.exeloncorp.com Nuclear July 2, 2004 U.S. Nuclear Regulatory Commission Document Control Desk Washington, D.C. 20555 Docket Nos. 50-277 and 50-278
Subject:
Monthly Operating Report for June 2004 In accordance with Technical Specifications, Section 5.6.4, "Monthly Operating Reports,"
we are submitting this Monthly Operating Report for Peach Bottom Atomic Power Station, Units 2 and 3.
Should you have any questions concerning this letter, please contact Mr. Chester Lewis at (717) 456-3245.
Respectfully, Joseph P. Grimes Plant Manager Peach Bottom Atomic Power Station I
JPG/PJD/NPA/CSL:cmg a6Oz C*a-Enclosures cc:
H. J. Miller, Administrator, Region I, USNRC C. Smith, USNRC, Senior Resident Inspector, PBAPS G. F. Wunder, Project Manager, USNRC (Cr oq-ILO3
!A"-(::52-,
I. INTRODUCTION Peach Bottom Atomic Power Station is composed of two Boiling Water Reactors and Steam Turbine/Generators located in Delta, Pennsylvania. Unit Two and Unit Three both have a Maximum Dependable Capacity of 1112 MWe Net. The Station is jointly owned by Exelon Nuclear and Public Service Electric and Gas. The Nuclear Steam Supply Systems are General Electric Company Boiling Water Reactors. The Architect/Engineer and Primary Construction Contractor was Bechtel Corporation. The Susquehanna River is the condenser cooling water source. The plant is subject to license numbers DPR-44 and DPR-56, issued October 25, 1973, and July 2, 1974, for Unit Two and Unit Three respectively, pursuant to Docket Numbers 50-277 and 50-278. The dates of initial Reactor criticality for Units Two and Three were September 16,1973, and August 7, 1974, respectively. Commercial generation of power began on February 18, 1974, for Unit Two, and September 1, 1974, for Unit Three.
w 1I.
SUMMARY
OF OPERATING EXPERIENCE A. Unit TWO Unit 2 began the month of June at 100% of maximum allowable power (3496 MWth).
At 2300 on June 5 h, Unit 2 reduced power to 70%, for a planned rod pattern adjustment. The Unit returned to maximum allowable power by 2215 on June 6th*
At 2300 on June 25th, Unit 2 reduced power to 72%, for a planned rod pattern adjustment. The Unit returned to maximum allowable power by 1127 on June 2 6th.
Unit 2 ended the month of June at 100% of maximum allowable power (3496 MWth).
B. Unit THREE Unit 3 began the month of June at 100% of maximum allowable power (3514 MWth).
Unit 3 remained at 100% of maximum allowable power (3514 MWth) for the entire month of June.
Unit 3 ended the month of June at 100% of maximum allowable power (3514 MWth).
III. OPERATING DATA STATISTICS A. Peach Bottom Unit TWO Operating Data Report for June 2004 DOCKET NO.:
DATE:
COMPLETED BY:
TELEPHONE:
50-277 July 2, 2004 Chip Lewis (717) 456-3245 OPERATING STATUS REPORTING PERIOD:
GROSS HOURS IN REPORTING PERIOD:
CURRENTLY AUTHORIZED POWER LEVEL (MWth):
DESIGN ELECTRICAL RATING (MWe-Net):
MAX. DEPENDABLE CAPACITY (MWe-Net):
UNIT 2 OPERATING STATUS June 2004 720 3496 1138 1112 2.
2.
3.
4.
5.
6.
PARAMETER NUMBER OF HOURS THE REACTOR WAS CRITICAL HOURS GENERATOR ON-LINE UNIT RESERVE SHUTDOWN HOURS NET ELECTRICAL ENERGY GENERATED THIS MONTH YTD 720.0 4,310.1 720.0 4,289.8 0
0 805,995.4 4,841,325.1 CUMULATIVE 194,076.5 189,604.9 0
187,992,863.2
III. OPERATING DATA STATISTICS B. Peach Bottom Unit THREE Operating Data Report for June 2004 DOCKET NO.:
DATE:
COMPLETED BY:
TELEPHONE:
50-278 July 2, 2004 Chip Lewis (717) 456-3245 OPERATING STATUS REPORTING PERIOD:
GROSS HOURS IN REPORTING PERIOD:
CURRENTLY AUTHORIZED POWER LEVEL (MWth):
DESIGN ELECTRICAL RATING (MWe-Net):
MAX. DEPENDABLE CAPACITY (MWe-Net):
June 2004 720 3514 1138 1112 1.
2.
UNIT 3 OPERATING STATUS 3.
4.
5.
6.
PARAMETER NUMBER OF HOURS THE REACTOR WAS CRITICAL HOURS GENERATOR ON-LINE UNIT RESERVE SHUTDOWN HOURS NET ELECTRICAL ENERGY GENERATED THIS MONTH YTD 720.0 4,367.0 720.0 4,367.0 0
0 816,801.4 4,969,362.1 CUMULATIVE 192,637.4 188,692.0 0
186,023,127.2
I IV. OPERATING DATA STATISTICS A. Unit TWO Shutdowns for June 2004 No. for Year Type Date (I)
Duration (Hours)
Reason (2)
Method of Shutting Down (3)
Corrective Actions/Comments No Unit TWO shutdowns for June 2004 B. Unit THREE Shutdowns for June 2004 No. for Year Type Duration Date (1)
(Hours)
Reason 2!
Method of Shutting Down (3)
Corrective Actions/Comments No Unit THREE shutdowns for June 2004 Legend (1) Type:
F - Forced S - Scheduled (2) Reason:
A. - Equipment Failure (Explain)
B. - Maintenance or Test C. - Refueling D. - Regulatory Restriction E. - Operator Training/License Examination F. - Administrative G. - Operational Error (Explain)
H. - Other (Explain)
(3) Method of Shutting Down:
- 1. - Manual
- 2. - Manual Trip/Scram
- 3. - Automatic Trip/Scram
- 4. - Continuation
- 5. - Other (Explain)