July 21, 2004 Mr. Michael R. Kansler, President Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601
SUBJECT:
REQUEST FOR ADDITIONAL INFORMATION REGARDING RELIEF REQUEST NOS. RR-65 AND 3-34 CONCERNING EXAMINATION QUALIFICATION REQUIREMENTS, INDIAN POINT NUCLEAR GENERATING UNIT NOS. 2 AND 3 (TAC NOS. MC1263 AND MC1264)
Dear Mr. Kansler:
By letter dated October 30, 2003, Entergy Nuclear Operations, Inc. (Entergy) submitted relief requests (RRs) 65 and 3-34 regarding proposed alternatives to certain examination procedure qualification requirements for Indian Point Nuclear Generating Unit Nos. 2 and 3. Specifically, Entergy has proposed alternative to the requirements in Appendix VIII to Section XI of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code.
The Nuclear Regulatory Commission staff is reviewing your request and has determined that additional information is necessary in order to complete its evaluation. The specific questions are in the enclosed request for additional information (RAI). During a telephone call on July 12, 2004, the Entergy staff indicated that a response to the RAI would be provided within 60 days.
Sincerely,
/RA/
Patrick D. Milano, Sr. Project Manager, Section 1 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-247 and 50-286
Enclosure:
As stated cc w/encl: See next page
July 21, 2004 Mr. Michael R. Kansler, President Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601
SUBJECT:
REQUEST FOR ADDITIONAL INFORMATION REGARDING RELIEF REQUEST NOS. RR-65 AND 3-34 CONCERNING EXAMINATION QUALIFICATION REQUIREMENTS, INDIAN POINT NUCLEAR GENERATING UNIT NOS. 2 AND 3 (TAC NOS. MC1263 AND MC1264)
Dear Mr. Kansler:
By letter dated October 30, 2003, Entergy Nuclear Operations, Inc. (Entergy) submitted relief requests (RRs) 65 and 3-34 regarding proposed alternatives to certain examination procedure qualification requirements for Indian Point Nuclear Generating Unit Nos. 2 and 3. Specifically, Entergy has proposed alternative to the requirements in Appendix VIII to Section XI of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code.
The Nuclear Regulatory Commission staff is reviewing your request and has determined that additional information is necessary in order to complete its evaluation. The specific questions are in the enclosed request for additional information (RAI). During a telephone call on July 12, 2004, the Entergy staff indicated that a response to the RAI would be provided within 60 days.
Sincerely,
/RA/
Patrick D. Milano, Sr. Project Manager, Section 1 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-247 and 50-286
Enclosure:
As stated cc w/encl: See next page DISTRIBUTION PUBLIC PDI-1 R/F C. Holden R. Laufer T. Chan P. Milano A. Keim D. Naujock S. Little B. McDermott, R-I C. Bixler, R-I OGC ACRS ADAMS Accession Number: ML042030011 OFFICE PDI-1/PM EMCB/SC PDI-1/SC NAME PMilano TChan RLaufer DATE 07/14/04 07/19/04 07/20/04 OFFICIAL RECORD COPY
Indian Point Nuclear Generating Unit No. 2 and 3 cc:
Mr. Gary Taylor Chief Executive Officer Entergy Operations, Inc.
1340 Echelon Parkway Jackson, MS 39213 Mr. John Herron Senior Vice President and Chief Operating Officer Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601 Mr. Fred Dacimo Vice President, Operations Entergy Nuclear Operations, Inc.
Indian Point Energy Center 295 Broadway, Suite 2 P.O. Box 249 Buchanan, NY 10511-0249 Mr. Christopher Schwarz General Manager, Plant Operations Entergy Nuclear Operations, Inc.
Indian Point Energy Center 295 Broadway, Suite 2 P.O. Box 249 Buchanan, NY 10511-0249 Mr. Dan Pace Vice President Engineering Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601 Mr. Randall Edington Vice President Operations Support Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601 Mr. John McCann Director, Nuclear Safety Assurance Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601 Ms. Charlene Faison Manager, Licensing Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601 Director of Oversight Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601 Mr. James Comiotes Director, Nuclear Safety Assurance Entergy Nuclear Operations, Inc.
Indian Point Energy Center 295 Broadway, Suite 2 P.O. Box 249 Buchanan, NY 10511-0249 Mr. Patric Conroy Manager, Licensing Entergy Nuclear Operations, Inc.
Indian Point Energy Center 295 Broadway, Suite 2 P. O. Box 249 Buchanan, NY 10511-0249 Mr. John M. Fulton Assistant General Counsel Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Senior Resident Inspector, Indian Point 3 U. S. Nuclear Regulatory Commission 295 Broadway, Suite 1 P.O. Box 337 Buchanan, NY 10511-0337
Indian Point Nuclear Generating Unit No. 2 and 3 cc:
Mr. Peter R. Smith, President New York State Energy, Research, and Development Authority Corporate Plaza West 286 Washington Avenue Extension Albany, NY 12203-6399 Mr. Paul Eddy Electric Division New York State Department of Public Service 3 Empire State Plaza, 10th Floor Albany, NY 12223 Mr. Charles Donaldson, Esquire Assistant Attorney General New York Department of Law 120 Broadway New York, NY 10271 Mayor, Village of Buchanan 236 Tate Avenue Buchanan, NY 10511 Mr. Ray Albanese Executive Chair Four County Nuclear Safety Committee Westchester County Fire Training Center 4 Dana Road Valhalla, NY 10592 Ms. Stacey Lousteau Treasury Department Entergy Services, Inc.
639 Loyola Avenue Mail Stop: L-ENT-15E New Orleans, LA 70113 Mr. William DiProfio PWR SRC ConsultaNT 139 Depot Road East Kingston, NH 03827 Mr. Dan C. Poole PWR SRC Consultant 20 Captains Cove Road Inglis, FL 34449 Mr. William T. Russell PWR SRC Consultant 400 Plantation Lane Stevensville, MD 21666-3232 Mr. Alex Matthiessen Executive Director Riverkeeper, Inc.
25 Wing & Wing Garrison, NY 10524 Mr. Paul Leventhal The Nuclear Control Institute 1000 Connecticut Avenue NW Suite 410 Washington, DC, 20036 Mr. Karl Coplan Pace Environmental Litigation Clinic 78 No. Broadway White Plains, NY 10603 Mr. Jim Riccio Greenpeace 702 H Street, NW Suite 300 Washington, DC 20001 Mr. Robert D. Snook Assistant Attorney General State of Connecticut 55 Elm Street P.O. Box 120 Hartford, CT 06141-0120
Indian Point Nuclear Generating Unit No. 2 and 3 cc:
Mr. David Lochbaum Nuclear Safety Engineer Union of Concerned Scientists 1707 H Street NW, Suite 600 Washington, DC 20006
Enclosure REQUEST FOR ADDITIONAL INFORMATION (RAI)
REGARDING RELIEF REQUESTS 65 AND 3-34 ON EXAMINATION QUALIFICATION REQUIREMENTS INDIAN POINT NUCLEAR GENERATING UNIT NOS. 2 AND 3 DOCKET NOS. 50-247 AND 50-286 By letter dated October 30, 2003, Entergy Nuclear Operations, Inc. (the licensee) proposed alternatives to certain requirements in Supplement 10 to Appendix VIII of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code) at Indian Point Nuclear Generating Unit Nos. 2 and 3 (IP 2 and 3). Specifically, the licensee requested in the Addenda to relief requests (RR) 65 and 3-34 (Enclosures 1 and 3 to the October 30 letter) alternatives to certain requirements for the procedure qualification requirements for inspection of ASME Class 1 pressure retaining piping welds. The staff needs the following information to continue its review:
- 1.
The licensee is requesting relief for Examination Category B-F, Pressure Retaining Piping Welds, Items B5.10, B5.40, and B5.70.
Provide a list of the unique identification numbers for the dissimilar metal welds (DMW) within scope of the RRs.
- 2.
The licensee stated that the its vendor contracted to perform the DMW examinations was not successful in achieving the ASME Code, Appendix VIII, Supplement 10, Paragraph 3.2 requirement for a depth sizing of weld defects with a 0.125-inch root mean square error value.
Provide the error value that was actually achieved, and provide an explanation on the acceptability of the this value.
- 3.
The licensee stated that the examination procedure is fully qualified only for the detection and length sizing of circumferential flaws at IP2 and 3.
Provide a discussion on the examination and disposition of axial flaws.