July 13, 2004
Dr. William G. Vernetson
Director of Nuclear Facilities
Department of Nuclear and
Radiological Engineering
P. O. Box 11830
University of Florida
Gainesville, FL 32611
SUBJECT:
RESPONSE TO NOTICE OF DEVIATION
(NRC INSPECTION REPORT NO. 50-083/2004-201)
Dear Dr. Vernetson:
Thank you for your response of June 10, 2004, to our Notice of Deviation issued on
May 11, 2004, concerning activities conducted at your University of Florida Test Reactor
facility. We have evaluated your response and found that it meets the requirements of
10 CFR 2.201. We will examine the implementation of your corrective action during future
inspections.
We appreciate your cooperation in this matter.
Sincerely,
/RA/
James E. Lyons, Program Director
New, Research and Test Reactors Program
Division of Regulatory Improvement Programs
Office of Nuclear Reactor Regulation
Docket No.50-083
License No. R-56
cc:
See next page
University of Florida
Docket No.50-083
cc:
Dr. Ali Haghighat, Chairman
Nuclear and Radiological Engineering
Department
University of Florida
202 Nuclear Sciences Center
Gainesville, FL 32611
Administrator
Department of Environmental Regulation
Power Plant Siting Section
State of Florida
2600 Blair Stone Road
Tallahassee, FL 32301
State Planning and Development
Clearinghouse
Office of Planning and Budgeting
Executive Office of the Governor
The Capitol Building
Tallahassee, FL 32301
William Passetti, Chief
Bureau of Radiation Control
Department of Health
4052 Bald Cypress Way
Tallahassee, FL 32399-1741
July 13, 2004
Dr. William G. Vernetson
Director of Nuclear Facilities
Department of Nuclear and
Radiological Engineering
P. O. Box 11830
University of Florida
Gainesville, FL 32611
SUBJECT:
RESPONSE TO NOTICE OF DEVIATION
(NRC INSPECTION REPORT NO. 50-083/2004-201)
Dear Dr. Vernetson:
Thank you for your response of June 10, 2004, to our Notice of Deviation issued on
May 11, 2004, concerning activities conducted at your University of Florida Test Reactor
facility. We have evaluated your response and found that it meets the requirements of
10 CFR 2.201. We will examine the implementation of your corrective action during future
inspections.
We appreciate your cooperation in this matter.
Sincerely,
/RA/
James E. Lyons, Program Director
New, Research and Test Reactors Program
Division of Regulatory Improvement Programs
Office of Nuclear Reactor Regulation
Docket No.50-083
License No. R-56
cc:
See next page
DISTRIBUTION:
PUBLIC
RNRP\\R&TR r/f
AAdams
CBassett
PDoyle
TDragoun
WEresian
SHolmes
DHughes
EHylton
JLyons
PMadden
MMendonca
KWitt
PYoung
RidsNrrDrip
DBarss (MS O6-H2)
BDavis (Ltr only O5-A4)
NRR enforcement coordinator (Only for IRs with NOVs, O10-H14)
ACCESSION NO.: ML041890089
TEMPLATE No.: NRR-106
OFFICE
RNRP:RI
RNRP:LA
RNRP:SC
RNRP:PD
NAME
CBassett:vxj
EHylton
PMadden
JLyons
DATE
07/ 12 /2004
07/ 12 /2004
07/ 12 /2004
07/ 13 /2004
C = COVER
E = COVER & ENCLOSURE
N = NO COPY