The University of Virginia Reactor Decommissioning Project 0
-411 CH12MHILL License R-66 Termination Request Volume 2 Field Data
-Final Status Survey Data Sheets
-Quality control Charts and Log Sheets June 2004
TIE ORIGINAL VERSION OF THiS DOCUMENT IS BEING SENT TO THE NRC DOCUMENT CONTROL DESK COPIES HAVE BEEN SENT TO DAN HUGHES & STEVEN HOLMES OF THE U.S.N.R.C.
The University of Virginia Reactor Decommissioning Project 0 CH2MHILL qW-
' License R-66 Termination Request Volume 2 Field Data Appendix B Final Survey Data Sheets Appendix C Field Survey Instrumentation Set Calibration and Quality Control Data June 2004
Appendix B -- Final Survey Data Sheets Survey Number Date Survey Description Pages UVA-FS-001 04/22103 Hot Cell, G026 13 UVA-FS-002 04/22103 Hot Cell, G025 13 UVA-FS-003 04/22/03 Hot Cell, G027 14 UVA-FS-004 04/23/03 Hot Cell Drain Piping 3 UVA-FS-005 04/28103 Hot Cell Static Counts 19 UVA-FS-006 04128/03 Hot Cell Window Opening Deleted-Incorporated into FS-005 0 UVA-FS-007 04/23/03 Hot Cell Crane 2 UVA-FS-008 04/23/03 Hot Cell, G025, Penetrations Deleted-Incorporated into FS-005 0 UVA-FS-009 04/22/03 Hot Cell, G025, Ventilation Deleted-Incorporated into FS-069 0 UVA-FS-010 05/12/03 Source Room, G022 14 UVA-FS-011 05/15/03 Mezzanine Crawl Space 14 UVA-FS-012 05/19/03 Source Room Sewer Line, G022, to Track Way Pit 3 UVA-FS-013 05/27/03 'Double-door" Room, G018 13 UVA-FS-014 05/28/03 Reactor Pool North End 9 UVA-FS-015 05/28/03 Reactor Pool South End 8 UVA-FS-016 06/02103 Lab, M008, Lower Walls and Floor 13 UVA-FS-017 06/02/03 Reactor Room, 131, Lower Walls 7 UVA-FS-018 06/05/03 Lab, M008, Upper Walls and Ceiling 9 UVA-FS-019 06/05/03 Reactor Room Floor, 131, East Side 7 UVA-FS-020 06/05/03 Reactor Room Floor, 131, West Side 7 UVA-FS-021 06/04/03 Demineralizer Rooms, M021 and M021A 15 UVA-FS-022 06/05/03 Mezzanine Hot Lab, M005 and M005A, Lower Walls and Floor 19 UVA-FS-023 06/05/03 Heat Exchanger Area, G024, Lower Walls and Floor 15 UVA-FS-024 06/09/03 RSO Lab, M019, LowerWalls and Floor 12 UVA-FS-025 06/10/03 Mezzanine Hot Lab, M005 and M05A. Upper Walls and Ceiling 17 UVA-FS-026 06/10/03 RSO Lab, M019, Upper Walls and Ceiling 11 UVA-FS-027 06/11/03 Boiler Room, M020, Lower Walls and Floor 11 UVA-FS-028 06/12103 Boiler Room, M020, Upper Walls and Ceiling 11 UVA-FS-029 06/16/03 Mezzanine Halls, M030, M031, Lower Walls and Floor 25 UVA-FS-030 06/17/03 Mezzanine Halls. M030, M031, Upper Walls and Ceiling 15 UVA-FS-031 06/18/03 Reactor Room Floor Drains and Piping 4 UVA-FS-032 06/19/03 Sample Preparation Room, G005, Lower Walls and Floor 13
- UVA-FS-033 06120103 Mezzanine Level Class 3 Offices 62 UVA-FS-034 06126/03 Counting Room and Hallway, G004 and G005A, Lower Walls and Floor 14 UVA-FS-035 06/23/03 Mechanical Room, G006, Lower Walls and Floor 6 WVA-FS-036 06/24/03 Outside Soil Areas 98 UVA-FS-037 06/25/03 CAVALIER Pit and Rooms G007 and G007A, Lower Walls and Floor 16 UVA-FS-038 06/26/03 Mechanical Room, G006, Upper Walls and Ceiling 6 UVA-FS-039 06/18/03 Under Reactor Room Floor, 131, Gamma Scan of Accessible Areas 7 UVA-FS-040 06/30/03 CAVALIER, G007 and G007A. Upper Walls and Ceiling 11
Appendix B -- Final Survey Data Sheets (cnt'd)
Survey Number Date Survey Description Pages UVA-FS-041 07102/03 Machine Shop, G007B and G008, Lower Walls and Floor 11 UVA-FS-042 07/07/03 First Floor Class 3 Offices 71 UVA-FS-043 07/07/03 Carpentry Shop & Storage, G008A and G019. Lower Walls and Floor 7 UVA-FS-044 07/08103 Hallway & Cleaning Closet, G016 and G017. Lower Walls and Floor 5 UVA-FS-045 07/07/03 Outside Paved and Graveled Areas 101 UVA-FS-046 07/09103 G007B, G008, G008A, G019, G016 and G017, Upper Walls and Ceiling 17 UVA-FS-047 07/14103 Ground Level Reactor Access, G020 West, Lower Walls and Floor 4 UVA-FS-048 07/14103 Ground Level Reactor Access, G020 Center, Lower Walls and Floor 5 UVA-FS-049 07/14/03 First Floor Hallway, 107. 124. 124A. 124B, 129, Lower Walls and Floor 26 UVA-FS-050 07/14/03 Counting Room and Hallway, G004 and G005A, Upper Walls and Ceiling 11 UVA-FS-051 07/14/03 First Floor Hallways, 107, 124, 124A, 124B. 129, Upper Walls and Ceiling 25 UVA-FS-052 07/14/03 Reactor Confinement Structure Roof 3 UVA-FS-053 07/15/03 Facility Main Building Roof 21 UVA-FS-054 07/17/03 Office and Instrument Lab, 127, 128 and 130, Lower Walls and Floor 12 UVA-FS-055 07/17/03 Reactor Room, 131, Upper Walls and Ceiling 14 UVA-FS-056 07/08103 Reactor Room, 131, M Core and B Core, Soil Samples 5 UVA-FS-057 07/17/03 Demineralizer Room, M021A, Wall Coring, Soil Sample Area 4 UVA-FS-058 07/19/03 First Floor Office, 126, Class 3 7 UVA-FS-059 07/21/03 Outside Reactor Facility Building Surfaces 7 UVA-FS-060 07/21/03 Locker Room, G002. Class 3 6 UVA-FS-061 07/21/03 Elevator Shaft and Electrical Room 3 UVA-FS-062 07/22/03 East Stairwell, MS1 6 UVA-FS-063 07/23/03 West Stairwell, MS2 6 UVA-FS-064 07/24/03 Asphalt Pad Outside Reactor Room Rollup Door 2 UVA-FS-065 07/25103 Ground Level Reactor Access, G020 East, Lower Walls and Floor 7 UVA-FS-066 07/28103 Biological Shield Wall 4 UVA-FS-067 07/31/03 Ground Level Reactor Access, G020, Upper Walls and Ceiling 12 UVA-FS-068 07/26/03 Reactor Facility Stack & Reactor Room Ventilation Exhaust Plenum 3 UVA-FS-069 07/30/03 Hot Cell Ventilation System 2 UVA-FS-070 07/31/03 Labs, M005 & M009, and Source Room, G022, Ventilation 4 UVA-FS-071 08101/03 Reactor Room, 131, Recirculation Ventilation System 3 UVA-FS-072 08/04103 Reactor Pool Heat Exchanger Suction and Discharge Piping 2 UVA-FS-073 08105/03 Underground Liquid Waste Storage Tanks Fill Line 2 UVA-FS-074 08/07/03 Sanitary Sewer, Bulk Access, Storm and Reactor Footing 'French" Drains 3 UVA-FS-075 08107/03 Reactor Pool Drains, Pool to Sump 3 UVA-FS-076 08/07/03 CAVALIER Drains to Storm Drain and Pond 3 UVA-FS-077 08107/03 Reactor Pool Drain Header Sump to Pond 3 UVA-FS-078 08108103 Asphalt Pad Outside Reactor Room Rollup Door & Soil Sample Locations 2 UVA-FS-079 08/13103 Reactor Pool Floor Soil Sample Locations 3 UVA-FS-080 09/04/03 Asphalt Pad Outside Reactor Room Rollup Door 2 UVAR-0245 09/17/02 Reactor Pond Sediments 23 UVAR-0449 01/21/03 Underground Storage Tank Excavation 2
( f' (
UVAP
- wRadiological Survey Form Location: iRWPIWP S urvey -Page Sumsy Typ 1 of13 Nuciear Reactor Facility Inside I UVA-FS-001 Final Status Survev Comments: Suyed Date: instrument SrldPl Cal. Due Probe Area Seied# Cal. Due 5 Eff. M x I Bkg Lc
.,sP06 _____
- - Bobby Leigh
--- ___ -f----1 . .. _ _ ___
0
__ - 0419 1M-2221 172051 4f2f2004 43-68 126 116718 4f2f2004 0.109 Savey ..... Jason bitrand o4i 3 M.2221 2 184010 w24r2034 44-10 nva 150873 I324f2004 n ____I____
Fnal StatuI S Addendum r4 meay Date: M-2221 103942 43-37 14301 149715 3f27f2004 0.114 Myer -
Static Counta Coordinates
= an Gros CPM OP~fO~an 2 Gross CPM DPlWnOOcm`a Unsfflhlelded -DPMJIOOOn -
No. NVt rJLce rh
- - 1 1 1-I I I I
=I I I=Ii
_ _II I I
=. I III I I I I _
= XT [ ~I _I ICF
_--II I-I- II I I I I I =. I I _ _I_
= g C D _ I ]H-
===I I- + IIT 1 _ I I I II
__ I I I I _~ _K I- _1I3 I - I
=
= --I I -
I I I I ! IE I1I1 II -
4-
_. i 4 I1
_ _ - I- =
_ __ l _
Form SECARP-21.2 Rev.0
Room G 026 East Wall 1 meter grid 4.66 4
3 N Id 2
1 Beta Scan Readings in CPM Survey # UVA-FS-001 Meter # 172051 L2221 1.2 1 0 -0.24 Probe# 116718 43-68 Date 4-22-03
. (
( c (
G026 North Wall 1 meter 4.66 300- 300- 300- 300- 300-400 400 400 400 400 4
275- 300- 300- 300- 300-375 400 400 400 400 3
300- 300- 300- 300-300- 400 400 400 400 400 2
300-400 300- 300- Hot Cell 300- 300-400 400 Window 400 400 1
300- 300- 300- 300- 250- 300-400 400 400 400 350 400
-0.15 0 2 3 4 4.5 1
Survey #UVA-FS-001 Beta Scan Meter # L2221 172051 Readings in CPM Probe # 43-68 116718 Date 4-22-03 E
Room G026 South Wall 1 meter grid 400- 4.66 300- 300- 350- 400-300-400 400 450 500 400 4
300-400 250-350 250-350 400-500 350-450 L 1 1 1 1i 3
/1 250- 200- 350- 350-200-400 300 450 450 300 2
200- 250- 200- 400- 400- 400-375 400 300 520 500 500 1
275- 200- 200- 400- 400- 400-400 300 300 500 400- 500 4.5 4 3 2 1 0 -0.15 Survey # UVA-FS-001- Beta Scan Meter # 172051 L2221 Readings I CPM Probe # 116718 43-68 Date 4-22-03 E
(. c
( (
G026 West Wall 1 meter grid 4.66 400 400- 400-500 500 500 4
35-.350- 350-450 450 450 3
400- 400- 400-500 500 500 2
250- 250- 250-350 350 350 1
Beta Scan Readings in CPM 250- 250- 250-30300 300 Survey # UVA-FS-001 Meter # 172051 L2221 -0.24 0 1 1.2 Probe# 116718 43-68 Date 4-22-03
Room G026 Ceiling 1 meter grid N
L 1.2 400- 350- 400- 400- 450-500 450 500 500 500 1
350- 400- 400- 350- 350-450 500 525 450 400 375-475 I 4 4.5 0 1 2 3 Survey # UVA-FS-001 Beta Scan Meter # 172051 L2221 Readings in CPM Probe # 116718 43-68 Date 4-22-03
( ( (
( (
Room G026 East Wall 1 meter grid 4.66 10200- 10400- 13300 10700 10800 13300-13500 4 10000- 10400- 12700-10800 10800 13700 3
N -4 10000-10600 10300- 11300-10800 12500 2
11000- 11700-11600 14100 1
Door Opening Gamma Scan 11300- 11500-Readings in CPM 12500 13000 Survey # UVA-FS-001 Meter# 184010 L2221 1.2 1 0 -0.24 Probe # 150873 44-10 Date 4-22-03
Room G026 Floor 1 meter grid N
A 1.2 10000-11900- 11700- 103 00-10300- 11000- 1 0000-14300 13500 11700 11700 11100 1
13000-16500 11000- 10000-110-11700- 10300- 11700 11100 11900- 13500 11700
-0.15 11700- 10300- 1 1000-0 1 1 129Ann 11700 11700 1 4 4.5 2 3 Survey # UVA-FS-001 Gamma Scan Meter # L2221 184010 Readings in CPM Probe # 44-10 150873 West side elevated readings Date 4-22-03 due to Co6O source in adjacent room
( Q (
(c (
Room G-026 South Wall 1 meter grid 4.66 12400- 12400- 12700-10600- 11900-13200 14100 14500 10900 13400 4
10200- 11500- 11600- 12100- 14500-10500 12700 15200 12601450 120 3
10000-11000- 13400-10800 111000- 11400-12400 11400 14300 13900 2
10900- 12200- 11000- 11500- 12600- 12800-12100 14900 11900 15000 15800 13700 1
10100- 12400- 11000- 12700-13100 14600 10500- 16100 13700 13400 11 11400 11540 4.5 4 3 2 1 0 -0.15 Survey # UVA-FS-001 Gamma Scan Meterh# 184010 L2221 Readings in CPM Probe # 150873 44-10 Date 4-22-03 E
Room G026 West Wall 1 meter grid 4.66 12400- 13200- 13200-13100 14200 13600 4
120-12300- 12600-12°00- 14900 13600 3
0 N 11800- 13400- 13100-13500 14600 13600 2
11600- 11700- 13200-13900 15000 13700 Gamma Scan 11200- 11800- 13500-Readings in CPM 12800 14500 14000 Survey UVA-FS-001 -0 24 0 1 1.2 Meter# 184010 L2221 Probe# 150873 44-10 Date 4-22 C (
c ( (
Room G026 Floor 1 meter grid N
L 1.2 1
4.5 Survey # UVA-FS-001-Meter# 103942------
Probe# 149715---------
Date 4-22 Room G-026 North Wall 1 meter grid 4.66 10700-11600-11600- 11100-11100- 10700-11000-12100 11600 11400 11100 4
12000- 11100- 10100- 9800-12600 11500 10800 10400 3
10400- 10000- 9800-11700- 11400 10800 10500 12400 2
12400- 11700- 10000- 9700-13200- 13100 13100 11500 11400 13400 1
11800- 10000- 9900- 10300- 9300-12200- 13100 11800 11300 11400 10700 12500
-0.15 0 2 3 4 4.5 1
Survey XUVA-FS-001 Gamma Scan Meter# 184010 L2221 Readings in CPM Probe # 150873 44-10 Date 4-22-03 E
( c (
( ( (
Room G026 Ceiling 1 meter grid N
L 1.2 10100-10200-11800- 11300- 11300- 10200- 10100-1 12200 12000 11600 10900 10600 12500.
13700-11900- 11000- 11000- 10300- 10300-12600 11900 11800 11500 10700
-0.15 0 1 11900- 12300- 4 4.5 12500 12900 2 3 Survey # UVA-FS-001 Gamma Scan Meter# 184010 L2221 Readings in CPM Probe # 150873 44-10 Date 4-22-03
C ( C UVAP 6 Radiological Survey Form Locatlon: IRW PIW P SuV Alt lS tuYTYPs:--- 9 Nuclear Reactor Facility InsIde I UVA-FS-0002 Final Stftus Su1vey Comments: Surveyed ByE Date: Instrument SerialIs Cl. Due Prob Ara& Serfallt Cal. Due _ I_ Max P Bkg Lc FhataStatus Suivy d oom G025 .~~ _,- ~_ _ _ __ _ _ _ _
............-----------E..... Bobb Leigh 04t22J03 M.2221 172051 4nt2004 43-68 126 116718 4/2r2004 _ O010 F Status-Fhal r
-a- Suvey Unit _0 Status Sunv v1
--- I =
Addendum 004
, ,_. IWT ,----
I tAMr Jason btrana R0 ,
1V _
04t22 n t@'
I M-2221 U
184010 I~mm.-I D-.,
I t-;
3/24/2004 4410 ni/a 150873 u7nn _
Mz-I.",
Is 'rt-w 49
.- I~ .....
- >J
_ 11X IJ l
ar I
3/24)2004 nh 01114 KJYl Smeer t w tIa) - Direct Fni B -betadoserateinmRadth -X-X. *Bouncda SOP-Sepl - dose Smears S _._ .. _ _ .. _ t _
Static Count B 11 Coordinates n
- il Gross CPM DPMM OOcma i UnthtShlelded DPM/1 COcma i No a l iJ cl i 5 5i CPM Net Lc No l Norttl l East l Ehvabon
= nla S nh ntal ntt C nh l nh nh nta _ nta l nh 1 ntsv
-ti t Et- : t
= I I C = _ 1
_> WE--__ __=
= l r c T T _ T 4
_ I I E___ _ __ I
$1! __ _ _ _ I
I 0 1 _ _ = 17
_t t __ _ _ _ __ q
= I _ I = = [
_ I I S__ _ _ _ _
I _ _
I I
= [ , = = = [
= l t-
-t <1 1=---- D -- _Tv Ww __ __ _ I l 1 1_ = _ = _ I Form SEC-RP-21.2 Rev.0
Room G-025 Floor 1 meter grid N
4.3 I I I J 1 680-900 cpm 1
FL 720-850 cpm I 3.5 I 1100w I 730-900 cpm 700-870 cpm 7 7 2.5 1 2 3 4 4.5 Survey # UVA-FS-002-Meter# 103942---------
Probe # 149715----------
Date- 4-22-03------------
(N
(
(C (
G025 South Wall 1 meter grid 3.8 9500- 8800- 8400- 8800-10400 10100 9600 9200 3
Inaccessibl Inaccessible Area 10000- 9500- 91000- 9800- Area 10300 10200100150 9400- 9300- 9400ot 1
Cell Windox 9800-11200-11400 13100-2 10100 9800 9400 10100 12500- 23100 9700 j .113300 1
9000- 8800- 9200- 10600- 10600- 13000-9900 10100 10700 11700 12100 21900 4.5 4 3 2 I 0 Survey # UVA-FS-002 Gamma Scan Meter# 184010 Readings in CPM Probe # 150873 West side elevated counts due to Date 4-22-03 Co6O source in adjadent room. I
Room G 025 Ceiling 1 meter grid T I T V Inaccessible Areas 9900- 9000- 9300- 10100-N 10400 10200 9800 10500 4.3 13000- 9300- 10000-27000 11100- 10100 9500 8800- 10200 3.5 12300 9300 9700- 9400- 9600- 10000-Inaccessible 10300 9900 9800 10600 Area 2.5 2 3 4 4.5 1
Survey # UVA-FS-002 Gamma scan Meter# L2221 184010 Readings in CPM Probe# 44-10 150873 West side elevated counts due to C060 Date 4-28-03 Source in adjacent room.
( c (
( (
Room G025 East Wall 1 meter grid 10300-3.8 9700- 10100-10500 10700 10900 3
N -4 10000- 9600-10500 10500 2
9000- 9000- 9400-9800 9800 10500 1
Gamma Scan 9200- 9200- 9300-Readings in CPM 10100 10100 10300 Survey # UVA-FS-002 2.5 Meter # L2221 184010 4.3 3.5 Probe# 44-10 150873 Date 4-22-03
Room G026 Floor 1 meter grid N
4.3 j6 12400- 11200- 10100- 10200- 10100-23400 12400 10500 10500 10300 3.5 12400- 10900- 10800- 10700-21800 11500 11400 11400 10100-10500 2.5 I 2 3 4 4.5 Survey # UVA-FS-002-----
Meter # 184010-------------
Probe # 150873--------------
Date 4-22-03----------
( Q (
( (
Room G025 West Wall 1 meter grid 3.8 8800- 9900-9100 10200 3
10400- 9900-10700 10400 2
10300- 10200-11000 10800 Shield Plug Opening 1
Gamma Scan 10700-Readings in CPM 10700- 11200 11100 Survey AUVA-FS-002 Meter# L2221 184010 2.5 3.5 4.3 Probe # 44-10 158073 Date 4-22-03
Room G025 North Wall 1 meter grid 3.8 9100- 8700- 9700- 9500-10300 10200 10600 10500 3
Inaccessible Inaccessible Area 8900- Area 10400 9900- 9700- 10000-10400 10400 10900 2
11500- 10300- 10500- 9700- 9500-15200 11700 10900 10400 10000 1
11500- 10200- 9800- 10100- 8400-17900 11400 10600 10700 10500 0
1 2 3 4 4.5 Survey # UVA-FS-002 Meter#L2221 184010 Gamma Scan Probe# 44-10 150873 Readings in CPM Date 4-22-03 West side elevated counts duet-o E Co6O source in Adjacent room.
( c (
( (
Room G025 North Wall 1 meter grid Z=4.3 3.8 Inaccessible 3
Area 2
I 0
- 1. 2 3 4 4.5 Survey # UVA-FS-002 Beta Scan Meter # L2221 172051 Readings in Probe# 43-68 116718 CPM Date 4-22-03
- E
Room G025 South Wall 1 meter grid
.3. 3.
3.8 250- 200- 250- 250-350 310 350 350 350 + 350 3
Inaccessible 200- 200- 200- Inaccessible 200-Area Area 300 350 300 300
- 4. - A. .r 2 200- Hot Cell Window 200- 250-225- 220-325 250 300 320 375 1
225- 250- 250- 250- 275-325 350 350 350 400 4.5 4 3 2 1 0 Survey # UVA-FS-002 Beta Scan Meter # L2221 172051 Readings in CPM Probe# 43-68 116718 Date 4-22-03 E
( ( (
( ( (
Room G025 West Wall 1 meter grid 3.8 300- 300-400 425 3
N 275- 250-375 350 2 - - n ___________
300- 300-400 400 1 Shield Plug Opening Beta Scan 300- 300-Readings in CPM 400 400 Survey # UVA-FS-002 Meter# L2221 172051 2.5 3.5 4.3 Probe #- 43-68 116718 Date 4-22-03
Room G025 Ceiling 1 meter grid 1 1 Inaccessible 300-Area 250- 250- 250- 400 350 N 350 350 L 4.3 350 250- 200- 250-300- 275- 250- 350 300 350 400 375 3.5 250- 200- 250-350 250-Inacce ssible 350 300 350 Area
__ __ _ _ _ __ __ _ _ L_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
2.5 1 2 3 4 4.5 Survey #UVA-FS-002 Beta Scan Meter # L2221 172051 Readings in CPM Probef# 43-68 116718 Date 4-22-03
( ( (
( (
Room G025 East Wall 1 meter grid 3.8 300-300- 400
- - ~~400__ _ _ _ _ _ _ _ _ _ _ _
3 N -4 250-250-350 300 2
200- 200-300 200- 325 300 1
Beta Scan Readings in CPM 190- 190- 190-325 325 300 Survey # UVA-FS-002 Meter # L2221 172051 1.8 1 0 Probe# 43-68 116718 Date 4-22-03
(7 ( (
UVAP Location: RRWPIWP 0 Radiological Survey Form Survey- Surw uTyPage of 14 Nuclear Reactor Facility In_ ide l UVA-FS-003 Final Status Survey
__ I i_
Comments:
Fal~t _ Surwnd Br. Date: instrument Serial,# __Cal. Due Prob Area Serial C Cal. Due a Elf. __ M x a Bkg Lc Fnl-ttus Surey.dRocrnG027 _
Bobby Leigh 0413 M.2221 172051 4127054 43-6 126 116718 412t2004 0.107 0 SJasn20 Strand 0 2221 103942 3i272004 43.37 430 149715 327/20D4 0.114 _
Status Sa a AddBdu o4 D M-222 t 184010 3I2412004 44-10 n/a 150873 32412004 n/a
...... .... ..... Frank Myr 04,23.03 MerS-
-rar1K
- - - - - - - - -=-
rIy r -* 1 Vrnx-uItrec-rta. paA..tnpt UtaLA.
- ouIlary aur - ap urr rag - rat to nose
-- rate -* -rerntrul Static Count I GrossCPM I DPM1100rm' ll I UnshlShleldedj No a 1 Ix I a Ii a iiNo4i CPM I :1IN North I East l Etevatlon nha ln/a nia inh a ll nha ra ln/a rna II
-1l I
Form SECARP.21.2 Rev.0
Room G027 Floor 1 meter grid Z=o 4.5 ON 5.4 1 3 4 4.3 Survey # UVA-FS-003 Meter# L2221 103942 Meter# 43-37 149715 Meter # L2221 *184010 Probe # 44-10 *150873 Date 4-22-03 Beta and Gamma Scans Readings in CPM Q (
( ( C Room G 027 North Wall 1 meter grid 2.75 10500-10900 2
10200-10900 1 I _ _ _ _ _ _ _ _ _ _ _ _
Survey #-UVA-FS-003 Meter # L2221 184010 Probe # 44-10 150873 10200-Date 4-22-03 11000 Ganmna Scan Readings in CPM 0 4.5 5.4
Room G027 South Wall 1 meter grid 4.66 9900-10800 4
9900-10800 3
10300-10900 2
9500-10200 1
Gamma Scan Readings in CPM 9700-10600 Survey # UVA-FS-003 Meter# 184010 L2221 Probe # 150873 44-10 5.4 4.5 Date 4-22-03
( c C
( ( C Room G027 North Wall extension 4.66 4
Steel shielded Lead Door 3
2.75 4.5 5.4 7400-7000- 9000 94000 E
East Side West side Survey # UVA-FS-003 Gamma Scan Meter# 184010 L2221 Readings in CPM Probe# 150873 44-10 Date 4-22-03
Room G027 West Wall 1 meter grid 4.66 A
I100-1 E=4.5 10800 3.75 10100-10800 2.75 9900- 7500- 9900- 10100- 10600-10700 9900 10400 10900 10900 2
N 9700 70 110 9600- 9700-97100- 10100- 10400 10500 Door 10500_10700 1
opening 9700 7000- 10000- 9500- 9600-Gamma Scan 10300 8400 10600 10100 9800 Readings in CPM 0
Survey # UVA-FS-003 1 2 3 4 4.3 Meter 184010 L2221 Probe # 150873 44-10 Date 4-22-03
( (
( ( (
Room G027 Ceiling 1 meter grid 1 meter 4.3 10200-10800 4
10400-10900 3
9900-10400 N 2 8600-10000 1
Gamma Scan 10300-Readings in CPM 10700 Survey # UVA-FS-003 Meter# 184010 L2221 Probe# 150873 44-10 4.5 5.4 Date 4-22-03
Room G027 East Wall 1 meter grid 4.66 348-E=5.4 401 4 300-396 3
2.75 370- 330- 350- 300- 270-420 420 470 370 350 2
280- 240- 250-300- 300- 390 360 350 370 410 1
380- 300- 350- 330- 360-450 470 450 450 475 0
4.3 4 3 2 1 Beta Scan Readings in CPM Survey # UVA-FS-003 N 4 Meter T 172051 L2221 Probe# 116718 43-68 Date 4-22-03
( ( (
( (
Room G 027 North Wall 1 meter grid N=4.3 2.75 350-450 2
350-430 1
350-Beta Scan 450 Readings in CPM Survey # UVA-FS-003 Meter# 172051 L2221 0 Probe# 116718 43-68 4.5 5.4 Date 4-22-03
Room G027 South Wall 1 meter grid N=O 4.66 272-347 4
302-369 3
250-370 2
280-375 Beta Scan 1 Readings in CPM 275-Survey # UVA-FS-003 400 Meter t 172051 L2221 Probe# 116718 43-68 Date 4-22-03 5.4 4.5
( (
C ( (
Room G027 North Wall extension N=1 4.66 389-486 4
259-344 Steel shielded Lead Door 3
1r 2.75 4.5 5.4 160-220 150-200 Beta Scan Readings in CPM East Side West side Survey # UVA-FS-003 Meter# 72051 L2221 Probe # 16718 43-68 Date 4-22-03
Room G027 West Wall 1 meter grid 4.66 -
317-409 3.75 291-354 2.75 270- 230- 250- 250- 300-340 300 350 330 410 2
N 200- 300-240. 250- 320- 31041 330 350 380 1 Door Opening 240- 250- 320- 250- 300-300 350 410 370 410 0
Survey # UVA-FS-003 Beta Scan 1 2 3 4 4.3 Meter 184010 Readings in Probe # 150873 CPM Date 4-22-03 Q (
( C Room G027 Ceiling 1 meter grid 1 meter 4.3 270-350 4 330-410 3
270-400 E 4-2 270-330 1 Z= 2.75 Beta Scan 340- Z=4.66 Readings in CPM 431 Survey # UVA-FS-003 Meter # L2221 172051 5.4 4.5 Probe # 43-68 116718 Date 4-22-03
Room G027 East Wall 1 meter grid 4.66 10200-11000 3.75 10200-11000 2.75 10300- 10300- 10100- 9900- 10100-11000 10500 10500 10300 10800 2
10100- 10100- 9800- 9700- 9600-10800 10800 10400 10000 10300 1
10300- 10300- 10100- 9700- 9900-11100 13900 10400 10300 10200 4.3 4 2 1 0 3
Survey # UVA-FS-003 Gamma Scan Meter# 184010 L2221 Readings in CPM Probe# 150873 44-10 Elevated reading 13900 due to discreet Date 4-22-03 Location bias static reading taken. See Survey UVA-FS-005 location # 23.
( ( (
C KuVAP C Radiological Survey Form 2, Location: ___ ______ ____ sum"e x survey W pg I f Laio:Nuclear Reactor Inside- UVA-FS-004 Final Status Srvey_______
Fb'I intermis.
Comments:
Su e~444 Cel r intkm eat 0.9metI surveyed By~.
Bobby Leigh Date:
04~23d Instrument M-2221 Ser"al 184010 Col. Dut ProbeArea SO"a 3124/2004 491-30eWa X339 Cal.
Due elm
_ - AIEll.
Wel m ax L Bkg Lc 0
Suve~~Urit32 son S trand l~a oa~_ _ _ _ _4 V-f.I C) *Sn- -1tot s=-DireclFnsk nLar a fB-eta closerate in mRadta -X--X--
- onlr SOP *StepOff Pad *I centdI r doese rat U Generadoserate Smears______Static Count p Coordinates Gross CPU DPM/l0cmn' Linshf~hiided DPM/100cmn' _ _ _
No. ct a .. No. CPM Net Lc No. NorthI East Elevation 1.13 were from the entrance in the Hot Cell to the Roadwav n/a a n I'na af 1 53 53 0 n/a I n/a n/a n/a WSa nJa n/a n/a 2 46 43 222 n/a 2 n/a n/a rim n/a nia n'a n/a 3 49 53 .298 n/a ! rga n/a n/a n/a na n/A n/a 4 47 49 .148 Wsa 4 n/a n/a WSa n/a nia n/ra n/a 5 55 49 1 445 n/a 5 r's n/a n/a n/a I We n/a n/a 6 95 83 889 n'a Sn/_ra n/a n/a n/a nia n/a n/a 7 73 49 1.778 n/a 7 n/a n/a n/a n's n.M n/a n/a 8 96 54 31112 n/a a n/a n/s n/a n/a a na On/ ns 9 93 83 741 n/a On/a n/a n/a n/a na W'S n/a 10 73 65 593 n/A 10 n/a n's nOS n/a nia n'a I'se I 1 85 74 815 n/S I1 n/a n/a n'a n/a nie WSa n' 12 75 93 .1,334 n/a 12 n/a nWA n'a n/a nia n's n/a 13 5 8 48 . 593 n/a 131 n/a n/a n/a hmimwith491130 probe_
n/a n/a ra n/a an/ 141 SS 52 m! n's ff rV 'a n's U14.-20 were from the entrance in the Roadway to the Manway at the n/a n/a n/a n/a Is 61 63 .148 n/a n/a n/a n/a the pipe W's n/a n/a n/a 16 T8 59 1.408 n/a n/a n/a n/a n/'a n/a n/a n/a 17 Al 69 74 n/a n/A ft' n's n/a n/a n/a n/a 18 - 78 72 445 ns W'a n/a n/a n/a n/a n/a WSa 1 9 70 63 519 n's n/a n/a n/a n/a n/a n/a n/a 20 47 51 .2 6 % n/a n/a n/a
- --,- -1Pprobe- - -
wms54 lo 99 qn Form SEC-RP-21.2 Rev.0
UVAP Radiological Survey Form 2 Locatlon: _ RWP#IWP lSurvey# lSrvey Type: IP92 Nuclear Reactor Facility Ou side I RaiUVAgFSl004A Final Status Survey Swesyd ST Date. Instrument Seri # Cal. Due Prob Ama SrtFlI Cal. Due rt Elft P Elf a Skig p kg raL, i L.
jna Comments' Survey of Hot Cell drain line at 0.9 n B egh 0423 . . .
intervals. Jason Strand 0412303 M-2221 172051 4r=Z34 43-68 16716t 4z()4 0107 n/a rva nta nla
_____________ _ ;W
_____........ e By Date:
c~rhttb;P-.--- an -- -y~~f -S50 - =~ = =-
t0Smear mow 0 DrectFnsh .. ar samnle i -beta doe. rate in mRad/h -X-X- *Boundary SOxi StenolrtPad a/y o tacth12_dose rate___General dose rat Smeas_ AJh iSet Scan StCounts Static_
Gross CPM DPWII00c l Gross CPM Audible Counts er minute DPMWI00mc a a __ia o. i yevnops No. Unh Shielde id Not P L-1 225-300 ro IDa" 1 284 281 22 290 Swab rom roadway to faW rnhiow 2 _ 2 225-315 ass 2 297 269 208 283 Swab from Hot Cel to roadway 3
3j_4_
___S- lll
( C FormSEj ' Rev.0
C C C UVAP Radiological Survey Form NuclonearReactor Facility Inside R P#WP 1 Srvy UVA FSO005 Final Status Paurvote1
- - Comments: SuveedW Date: Instrument Serials! Cal. Due Probe Area SerialS Col. Due aEft. 0 Ef I. a Bkg. Ii Bkg a L. L.
Final status Survey o.fthe Hot Ccij Static counts and smears Gam a.can.o.Shel.Pl g.
Alice Thompson Bobby Leigh ason I5rand 04RW Tennelec-04CM10 M-2221 04/81 M.2221 6405 j 4/16rW04 172051j, 4/2100 184010 324200 Noa n/a n/a 43-68 126 116718 44-10 We/ 150873 n/a 4)24120 3/24)20 Noa n/a 0'09 n/a Noa 0.10 7 1
n/s Noa No j na Wea n/an--n n/a ns J j n/
)=Wx -rc Fil & arsripeB bt dose rate in mRadth1 -.X-.X - Bouxrdaq SOP. SltepOffPad x/y osntawi12 dose rate N Ge~wl dose ra!
S eAlpha/Beta Scan _____ StaticCounts 2
Gross CPM DP 0lcm Gosas CPM Audible Counts per Minute DPMflO0cm`
No. aT Cs~ a. y h passial No. Unsh Shiel No P6 I _se I na n/a Nos 1 435 340 705 319N ,E05 .
3 e o r N/a n'a 3 419 302 18 30425 N O . E 2 .5, _ _
Z 0.25_ __ __ _ __ __ _ __ __ _ __ __ _ __ _
72 27
______W_6 690 _2 N 32.5.E .4._.Z0.25
___il__ 4 2 31 35 3 7N 12.5.E 4.5._Z 42.0 a______We__ 419_ 30___81__0__ N 054.0, .iZ2476 9__ile9_9 2 1 1 09 2 9N 4.3. E60.5, Z 1.70 10 0 WN N 10 286 244 312 20N 64.0. Z 1.75 O4.3.
11 1 r~a No 1 39 254 1009 275N43.5 64.5.1-Z1.75 12 1 f~a No 2 35 23 912 263N 2.5. E 54.. Z 2.25 13_3__ __NI_3I 20 233__ _24_ 2 N 3.5,_E64.5._Z O2.
1____oe 28
__39_26_49 N 3.._0 2.E5. _,Z3.85
_ _ _OC5 Noa N/a 0 339 2750 660 2873 N43.5 E 2.5. Z 31.75 21 Noa nile 217 382 361 141 331 N 3.5 41.25.Z 1.25 is 2Z1 N 3.1, 62.4.9 E 4d, Z 2n2 Bia25 SNal5l QC Q r~ n/ QC 339 250 660 273N 3.5. E65.3.Z 3ia8 I II I 11 I I I I I 1 FormSEC-RP-21 .2Rey 0
Room G026 East Wall Imeter grid E =4.5 4.66 4
-I 3
N -. 9
- ~2 Door Opening 1
Survey # UVA-FS-005 Meter # L2221 172051 1.2 1 0 -2.4 Probe # 43-68 116718 Date 42803
( ( C
( C Room G 026 South Wall 1 meter grid N=0 4.66 4
3 2
l
. 4.5. 4 3 1 0 -0.15 Survey # UVA-FS-005 Beta Scan Ha denotes walls Meter# L2221 172051 Readings in CPM ProbeI# 43-68 116718 o denotes smear and E 4 Date 4-28-03 static count locations
Room G026 West Wall 1 meter grid E=O 4.66 I-4 3
2 1
Survey # UVA-FS-005 0 1 1.2 Meter # L2221 172051 Probe# 43-68 116718 Date 4-28-03
( c (
( ( C Room G026 Floor 1 meter grid z=o N
A 1.2 1
0 1 .1. L .
4 4.5 2 3 Survey # UVA-FS-005 Meter # L2221 172051 Probe # 43-68 116718 Date 4-28-03
Room G-026 North Wall 1 meter grid 4.66 I T I - F 4 4 +
Inaccessible Wall 3 Wall 1 t .4.
2 Hot Cell (i) Window Q 1
5
-0.15 0 2 3 4 4.5 1
Survey # UVA-FS-005 Beta Scan Meter # L2221 172051 Readings in CPM Probe # 43-68 116718 O denotes smear and Date 4-28-0.3 static count location E
( (
( ( (I Room G026 Ceiling 1 meter grid Z = 4.66 N
1.2 1
© 0 8
0 1
A a. - . 4 4.5
-0.15 2 3 UVA-FS-005 Beta Scan Meter# L2221 172051 Readings in CPM Probe# 43-68 116718 o denotes smear and Date 4-28-03 static
Room G027 Floor 1 meter grid Z=o 4.5 5.4 0 1 2 3 4 4.3 N
Survey # UVA-FS-005 Beta Scan Meter# L2221 172051 Readings in CPM Probe# 43-68 116718 O denotes smear and static Date 4-28-03 count locations
(. ( (
( (
Room G 027 North Wall 1 meter grid 4.66 N= 1.2 4
3 2.75 2
9 1 N=4.3 Survey # UVA-FS-005 Beta Scan 0 Meter # L2221 172051 Readings in CPM 4.5 5.4 Probel# 43-68 116718 o denotes smear and Date 4-28-03 static count locations
Room G027 West Wall 1 meter grid 1 E=O 3.75
+l I I 2.75 N
2 4-13 Door 1 Opening 4 4 0
1 2 3 4 4.3 Survey # UVA-FS-005 Beta Scan Meter XL2221 172051 Readings in CPM Probe # 43-68 16718 O denotes smear and static Date 4-28-03 count locations
( c (
( ( (
Room G025 North Wall 1 meter grid N =4.3 3.8 Inaccessible Area 3
2 1
0 1 2 3 4 4.5 Survey# UVA-FS-005 Beta Scan Meter # L2221 172051 Readings in CPM Probe # 43-68 116718 o denotes smear and Date 4-28-03 static count locations E
Room G025 South Wall 1 meter grid N=2.5 3.8 Inacc ssible 3 Inaccessible 2
E Hot Cell Window 1
4.5 4 3 2 1 2.0 Survey # UVA-FS-005 Beta Scan Meter # L2221 172051 Readings in CPM Probe # 43-68 116718 O denotes smear and Date 4-28-03 static count location
( c (
( ( (
Room G025 Floor 1 meter grid Z=o N
L.
A 4.3 Dioi 3.5 2.5 0 1 3 4 4.5 Survey # UVA-FS-005 Beta Scan Meter # L2221 172051 Readings in CPM Probe3 43-68 116718 o denotes smear and static Date 4-28-03 count locations
- Room G025 West Wall 1 meter grid E= 1.25 3.8
- N Beta Scan Reading in CPM o denotes smear and static count location Survey# UVA-FS-005 3.5 4.3 2.5 Meter# L2221 172051 Probe# 43-68 116718 Date 4-28-03
(. c (
(
Room G025 Ceiling 1 meter grid Z=3.8 2.5 3
3.5 N
4 A.
4.3 ______________ ______________ A A 1 2 3 4 4.5 Survey 3 UVA-FS-005 Beta Scan Meter # L2221 172051 Reading in CPM Probe# 43-68 116718 o denotes smear and Date 4-28-03 static count location
Room G025 East Wall 1 meter grid E =4.5 3.8 l
N I' 3 yLy 2
Door Opening Survey # UVA-FS-005 Beta Scan Reading in CPM 1.8 1 0 Meter # L2221 172051 Probe # 43-68 116718 O denotes smear and Date 4-28-03 static count location
( ( (
( C Room G027 South Wall 1 meter grid N=O 4.66 4
0 3
2 Beta Scan Readings in CPM 1 O denotes smear and static count locations Survey # UVA-FS-005 Meter# L2221 172051 Probe# 43-68 116718 5.4 4.5 Date 4-28-03
Room G027 Ceiling 1 meter grid 1 meter 4.3 14 4 Z = 2.75 3
N 2 1
Beta Scan Readings in CPM Z = -4.66 0 denotes smear and static count locations Survey # UVA-FS-005 Meter # L2221 172051 Probe# 43-68 16718 4.5 5.4 Date 4-28-03
(. c (
c (7 Room G027 East Wall 1 meter grid 4.66 E=4.3 3.75 7 t 2.75
-4 + * +
2
-* t 1 1
0 0
2 1 4.3 4 3 N .4 Survey # UVA-FS-005 Beta Scan Meter# L2221 172051 Readings in CPM Probe # 43-68 116718 O denotes smear and Date 4-28-03 static count locations
UVA-FS-006 was not used.
(C C (
UVAP f Radiological Survey Form Location: RRWPIWP _ SUr jSurveyTye: SPaage O2 Nuclear Reactor Inside I -UVA-FS-007 Final Status Survey Comments: I Dte:
a Instrument Serial I Cal. Due Probe Area Serial C Cal. Due JJ_Eft. M ax B Bkg Lc FdStts Svy d Room 0025 t Alice Thompson O54503 Ttrmebei 64052 4n6t2004 nha We nWe nhI nh Gtaspebcrtt ... _Oy Leig 04L2e M-2221 103942 3t2tt200t 4368 t26 160790 3127tt204 0109 249 MAM Jason Strand 04t23t03 _._ _ . 1 Frai Stat Surms Addendum 004 Revid By' Date Snt oversu os cad X-
- Boundary SOP Step off Pad 'ty
- ecntadJ12 dose rate #* General dose ra St Nawasample B -
Smears Static CountB- Coordinates Gross CPM oPM/lOocn,' Unsh/Shlelded DPMt1Xemr' No a a No. CPM I Net Ic No. North East Elevation t See 1 1132 215 6.677 249 1 nha j Va nsa I
L
_ -- I 1 _I- I -I I I I1
_I I _ I I I 1
= I I
=
= - _-
-t
-t
- t - I. - I - ii - fI-? - *t*- it. - f-I-f Form SEC.RP.21.2 Rev.0
Room G025 Overhead crane side view 2 meters 4 0.
Beta Scan Reading in CPM o denotes smear and static count location Survey # UVA-FS-007 Meter # L2221 103942 Probe 3 43-68 160790 Date 42303
(. ( c
UVA-FS-008 was not used.
UVA-FS-009 was not used.
( ( (
UVAP Radiological Survey Form Location: RWPIWP surve Survey Type: PeI 0f 14 Nuclear Reactor Inside I UVA-FS-010 Final Status Survey I Date: Instrument Serial Du Prob Afea Serial U Cal. Due Elf cax S Bkg LC MI
.Jason Comments: ed y
== . . Alice Thorpson 05M1503 Temnalec 64052 411612004 nWe nfa We rl a nha Strand 05/13fO3 M.2221 103942 3127/2004 43-8 126 160790 3127oo4 og 347 at fveyAle .mrto4 00St Brad Myers _ 5O3t03 M-2221 184010 3/24/2004 4410 tOna 150873 3124r2__4 = nfa
.................................... ra ~
Reredv~~ m D ate :_ _
_., ^ ~~~. \.fAX =...Franl MYelavr SM.... ~4103_
D~__.-A~cnc . _.*
-o.rmarmr b are nsrea, tra.ampia - c -Uma aose rawemradnn -xA-x I- ttouc ary SOP
- Sw8 O1 Pad
- canaruc 1ose WYS rare 5
- Geneoni OOse ra Smears _ Static Count5 Coordinates _A Gross CPM DPMltOWcrn' Unsh!Shielded DPM fOOcrn' __ _
No. a a No. CPM Net Lc No North East Elevation I see 1 368 3B3 .109 332 1 0 1 2.5 2 f Utche 2 S90 305 2.075 296 2 0 1.75 1 Repoft - 3358 340 131 313 3 0 3 2.5 4 4 373 338 255 312 4 0.5 3.2 1.75 5 5 388 325 459 306 5 2 3.2 2.5 6 6 330 384 .29 332 6 125 3 2.5 7 7 613 310 2206 299 7 2 32 0.5 a a 591 328 1.915 307 8 2.8 3 0.75 9 9 384 326 422 306 9 2.8 1.75 225 10 _ _ _10 681 297 Z796 292 10 2 1.S 0.25 11 11 360 362 .15 323 11 2 1.5 225 12 12 609 342 1.944 314 12 1.75 1 0.75 13 13 5^8 375 1.624 329 13 0.5 0 1 14 _ 14 459 401 422 340 14 1.25 1 i 2S 15 _ 15 570 388 1,325 334 15 0.5 1 I 0 16 _ _ 18 536 418 l59 347 1s 0.5 3 0 17 ____ 17 544 354 1.383 319 17 2 1.75 0 QC QC 551 356 1,420 320 QC 2 1.75 0 i _Ini I _ . .a
=
Form SEC'RP-21.2 Rev.0
UVAP at7 Radiological Survey Form Location: IRWPIWP Survey# SurveyType: Page2of 14 Nuclear Reactor Inside IUVA-FS010A Final Status Survey Comments: Date: Instrument S5rial# Cat. Due Arva Serial# Cal. Due - Elf. M nx p Bkq Lc aSatusSveyoRoom022 AlicTompon O103 Terrielec 64052 4t1it2Wt4 nWa Wa n/a nba nWa I
.a..sSuv..Uni8
. . Jason Strand O5/13103 M-2221 103942 3127/2004 43-68 12 160790 307/2004 _ l 091 347 L! Sjs~uvS. rdn~ey u004 Brad Myers Ot1303 M-2221 184010 3124/2Wo4 44-10 nva 150873 3124/2004 . nta l Reve..d B Date. _ _ _ _ _ _ _ _ _
........ ~ ..... _rank Mers OY/14tO3 l=
KeYI 0 *Smeaar b,
- DirectFns &-air sample
- 60undanv SOP*SteoNr O Pad x
- crnbctt12 doseratea
- General dm ra Smears Aph Bta Scn ICounts l GrossCPMl Gross Countrs Audi It Minute DPMv t100cm North
- N East
- E Height - Z No C. I B a I t lNoO a Ve"r1"ollpassdall I Unsh I Shielded Net B 1, 260-430 368 1 383 1 -109 332 0 25 210-590 590 305 2075 296 I 11 Report 260t430. 131 _313 0 1.75 2.5 370-570 l no l 312 0.5 3 1.75 300-400 388 306 2 32 25 300-390 380 384 1 -29 332 125 32 25 430-620 pass 1 9.
613 i t 591 310 32ti
-3i I 2206 299 328 T 1915 307 I 422 306
_292
-15 _323 2
2.8 28 2
2 3
32 3
1.75 1.5 i 0.5 075 225 0.25 225 480480 n 1 ass 342 j 1944 _314 1.75 1.5 0.75 3804620 375 _ 1624 329 0.5 1 1 300-390 459 401 1 422 340 125 0 25 10391 It DasM 570 338 T 1325 334 05 1 0 536 F 418 859 _347 0.5 1 0 11 1383 _319 2 1 3 0 4: I t c-_ 5f-r50I _320 2 175 0
==
- I
( c Form SE( Rev.0
( (
Room G022 East wall 1 meter grid E=3.2 2.53 300- 300- 320-420 440 440 2
0 410- 370- 390-570 570 550 N -4 1
450- 430- 430-620 600 600 Beta Scan Readings in CPM O denotes smear 2.8 2 1 0 and static count locations Survey # UVA-FS-010 Meter #103942 L2221 Probe# 160790 43-68 Date 5-13-03
Room G022 North wall 1 meter grid N=2.8 2.53 350- 350- 350- 370-420 420 420 430 2
320- 340- 370- 420 550 570 58 610.
1 12618 500- 480- 500- 550 640 640 660 680 Beta Scan Readings in CPM O denotes smear and 0 1 2 3 3.2 static count locations Survey #UVA-FS-010 Meter #103942 L2221 Probe'#160790 43-68 Date 5-13-03
( ( (
I ( (
Room G022 South wall 1 meter grid N=O 2.53 1 280-260- 260- 260- 430 380 380 390 2
E 4-260- 210- 410- 450-490 380 550 590 1
380- 300- 430- 610-540 410 570 610 Beta Scan Readings in CPM o denotes smear and 3.2 3 2 1 0 static count locations Survey # UVA-FS-O10 Meter# 103942 L2221 Probe# 160790 43-68 Date 5-13-03
Room G022 West wall 1 meter grid E=O 2.53 390- 370- 11 370-480 480 460 2
420- 400- 380-580 540 510 1
430- 400- 400-580 560 510 Beta Scan Readings in CPM O denotes smear and static 0 1 2 2.8 count locations Survey #UVA-FS-010 Meter # 103942 L2221 Probe# 160790 43-68 Date 5-13-03
( ( (
( (
Room G022 East wall 1 meter grid E = 3.2 2.53 1 616000-16500 2
15800-16200 4-N 1
6 1 15600-16400>
Gamma Scan 2.8 2 1 0 Readings in CPM Survey # UVA-FS-010 Meter# L2221 184010 Probe # 44-10 150873 Date 5-13-03
Room G022 Floor 1 meter grid Z=o 2.8 2
1 E.
Gamma Scan 0 3.2 1 2 3 Readings in CPM Survey #UVA-FS-010 Meter# L2221 184010 Probe# 44-10 150873 Date 5-13-03 c (
( (7 Room G022 North wall 1 meter grid N=2.8 2.53 I 1 0 17 1 16500-17500 ]
2 11 0 16500-17500 1
1 15400-16500 -_
Gamma Scan 0 1 2 3 3.2 Readings in CPM Survey # UVA-FS-OIO Meter/# L2221 184010 Probe# 44-10 150873 Date 5-13-03
Room G022 South wall 1 meter grid N=O 2.53 2
E 4-1 Gamma Scan 3.2 .3 2 1 0 Readings in CPM Survey # UVA-FS-O1O Meter # L2221 184010 Probe # 44-10 150873 Date 5-13-03
( (
( ( (
Room G022 West wall 1 meter grid E =O 2.53 2
1 Gamma Scan 0 1 2 2.8 Readings in CPM Survey # UVA-FS-O1O Meter# L2221 184010 Probe# 44-10 150873 Date 5-13-03
Room G022 Ceiling 1 meter grid Z=2.53 2.8 2
1 o, E Gamma Scan 0 1 2 3 3.2 Readings in CPM Survey #UVA-FS-010 Meter # L2221 184010 Probe # 44-10 150873 Date 5-13-03
( (
( (
Room G022 Floor 1 meter grid Z=o 2.8 380- 410.
480
_ 2 N
420-400- 440.
400- 520 520 550 500 1
400-400 420-4 0-560 420- 1 430-570 540 15 510 Beta Scan Readings in CPM O denotes smear 0 2 3 3.2 1
and static count locations Survey #UVA-FS-010 Meter #103942 L2221 Probe #160790 43-68 Date5-13-03
Room G022 Ceiling 1 meter grid Z = 2.53 2.8 2
N I 1 Beta Scan Readings in CPM 0 1 2 3 3.2 o denotes smear and static count locations Survey # UVA-FS-010 Meter # L2221 103942 Probe # 43-68 160790 Date 5-13-03
( (
( ( (
UVAP
_ _ __ Radiological Survey Form Location: RWPIWP lSurnt# lSurveyTy":Pg I8 O14 of Nuclear Reactor Facility In;ide l UVA-FS-01 1 Final Status Survey of Comments: B Date Instrument Serial l Cal. Ou Prob Area Serial 8 Cal. Due 4 P Eff. l Maxp Btg Lc FnSalStatus Sury-8se Mezzaasne Crast llc ompson 0/1910 Temelec 64052 4/16r2004 nha nhaS rnta nta Ih _ _I sat rte due to nattraly occt Ra Blevated ra yers 055O/ MW2221 103942 3127/2J04 43-68 126 160790 Y327t204 0.109 I 367 soi lloor Fnal s;tts survey unit 42 Jasaon Strand O51SJ33 M.2221 184010 3124t2DD444.10 nta 150873 242 4 nra Frt uv~ttu defi ~4and 007 R tt~v Br. D t
_-- Dret Fn_ ran Mers 051903 Key I 0 *Smerxxxxx*Drectrnsl,^ a= arnime -X-X
' -beta doserate in mRadh Bourndary SOP_Step Off Pad contactt2c cose rate
- General dosera Smeas Static Count P I Coordinates Gross CPM DPMloocr1e' UnshShlelded DPMJlOcm' I In Meters_
No. n B Q No. CPM Net Lc No. north east elevation I See 1 614 419 1.420 347 1 0 2.75 15 2 2 566 405 U131 341 2 0 625 1.5 3 Report 3 663 430 1.842 352 3 1.5 0 25 4 4 763 467 2.155 367 4 45 0 0.75 5 5 740 362 2.607 332 5 6.75 110 1.5 6 1 6 654 399 1.857 339 61 6.75 8.0 0.5 7 1 7 550 348 1.471 316 71 45 725 2.5 8 I 8 590 _262 2Z243 285 81 1.5 1 64 1.5 9 9 529 I 415 830 346 1 91 2.5Z 1 3 10 10 51S j 417 735 346 10 2.5 4.5 3 11 __i _ 11 471 359 815 321 11 5.5 6.25 3 12 i __t12 425 269 990 288 12 5.5 2 75 3 QC -C 466 321 1.056 304 QC 55 2.75 3 6'aotlea Ia C
1 13 UVA-FS-01 1.5 1 0 14 uVA-FS-02 j 1.5 4.5 0
=_ 5 UVA-FS403 4.5 625 0 16 UVA*FS404 7.5 4.5 0 17 UVA-FS45l 4.5 2.75 0 Additonal ramdompoints tooset' Complete data et __ __ _
1 18 669 452 1.5E0 361 0 2.8 2.5 19 19 805 528 2.017 390 72 3 2.5 20 1 20 764 501 1.915 380 9.5 58 11.8 2 _ 21 953 505 3262 381 3.8 72 i 08 Forn SEC.RP.21.2 Rev.0
[ezzanine Crawl Space Floor N 1 meter grid Z =0 7A 6.75 900-970 sL 900-1050 8800 1040 9870 8 900-4 1070 850- 7 3 _ _
780- 900- Beta scan 1000 1050 Readings in CPM 750-990 Survey # UVA-FS-011 1 Meter# 103942 L2221 870- 850- Probe# 160790 43-68 930 910 Date 5-14-03 0
1 2 3 4 5 6 6.4
( ( (
( (
Mezzanine Crawl Space North Wall 1 meter grid N=9.5 N=6.5 N=6.75 730- 700-N=6~
800 800 3
730- 715-2 830 745 1.2' (D700-850 0.8 I I , 0il Beta Scan 0.66
/ 5 6 7 8 8.5 Readings in CPM o denotes sme4ar and 0 static count locations 1 2 3 Survey # UVA-FS-01 I Meter# 103942 L2221 Probe # 160790 43-68 Date 5-14-03
Mezzanine Crawl Space South Wall 1 meter grid N=O 3
2 Beta Scan 1 Readings in CPM 0 denotes smear and static count locations Survey # UVA-FS-01 1 6.4 6 5 4 3 2 1 0 Meter# 103942 L2221 Probe# 160790 43-68 E <
Date 5-14-03
( C. (
( ( (
Mezzanine Crawl Space West Wall 1 meter grid E=O E=1 3
3 2
2 1.25 1
0 Beta Scan I 0
Readings in CPM o denotes smear and static 7 8 9 9.5.
count locations -k N Survey # UVA-FS-01 1 Meter# 103942 L2221 Probe# 160790 43-68 Date 5-14-03
Mezzanine Crawl Space East wall 1 meter grid E=8.5 E=6.4 3
660- (
780 2
740- 760-830 870 1
21 800- 720-0.8 s
% 900 840 Soil - I Beta Scan 0.25 Readings in CPM O denotes smear and 65 6 5 4 3 2 1 0 static count locations Survey # UVA-FSOI I N Meter# 103942 L2221 Probe # 160790 43-68 Date 5-14-03
( (
( 9(
I( N Mezzanine Crawl Space Ceiling 8 / 4 L 1 meter grid ,--
540-I 660 630\
7 - 4 6.75 Z=3 4 4 6
X/
540- 530-
© .640 640
- 540-5/ 650
/
4 1_ 570- 530- 510-680 615 620 3
2 I 550-640 515-630 470-580
/ Beta Scan Readings in CPM 0 denotes smear and static count locations 1!
I Survey # UVA-FS-01 1 580- Meter# 103942 L2221 640 Probe # 160790 43-68 0 _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ ___ ___ ___ - I Date 5-14-03 1 2 3 4 5 6 6.4
Mezzanine Crawl Space Ceiling 9 N 1 meter grid 8I/ I______________
_________________________ L 21500-Z=3 22500-22800 7 / 23000 6.75 6
I I
_ /Z I/
X/11 19800- 21500-21000 23000 I l I I I
/
.1 20000-20700 4 l -I 3
/ 19500-20100 20300-21400 20200-21400
/
l 2 ____ I ____ ____ ____ ___
/ /
18500- Gamma Scan 18500- 18800-19200 Readings in CPM 19800 20000 1 l l .- l Survey #-UVA-FS-01 1 0
/ 18000-19500 1
2 3 4 5 6 I
6.4 Meter # L2221 184010 Probe# 44-10 150873 Date 5-14-03
( c (
( ( (
Mezzanine Crawl Space South Wall 1 meter grid N=O 3
20000-21300 2
21000-21900 20700-22500 Door Gamma Scan Readings in CPM 1 20800- 22300-21200 23000 Survey #-UVA-FS-01 1 Meter # L2221 184010 Probe t# 44-10 150873 6.4 6 5 4 3 2 1 0 Date- 5-14-03 E --
Mezzanine Crawl Space West Wall 1 meter grid E=O E=1 3
E=3 E=5 23500- 3 25400 24000-2 24800 North 2 2 1300- 22800- Wall 23000 24000 1 I-- 1.25 24800- 25200- 1 25400 25500 _ I---
Soil 0
1 2 3 4 5 6 6.75 Gamma Scan Readings in CPM 7 8 9 9.5 Survey #UVA-FS-01 1 N Meter#L2221 184010 Probe # 44-10 150873 Date 5-14-03
( (
( (
Mezzanine Crawl Space East wall 1 meter grid E=8.5 E=6.4 3
25300 26200 2
26600- 24600-27100 25000 0
0.8, 25500- 24000-26500 24700 0.25 Gamma Scan 6.5 6 5 4 3 2 1 0 Readings in CPM N .4 Survey #-UVA-FS-01 1 Meter #- L2221 184010 Probe # 44-10 150873 Date 5-14-03
Mezzanine Crawl Space North Wall 1 meter grid N=9.5 N=6.5 3
2 Z=0.8 Gamma Scan z=0.66 Readings in CPM 8.5 0
1 2 3 Survey #-UVA-FS-01 1 Meter # L2221 184010 Probe # 44-10 150873 E Date 5-14-03
(. ( (
Mezzanine Crawl Space Floor
(
N Gamma Scan Readings in CPM Survey #-UVA-FS-O1 I Meter #- L2221 184010 Probe # 44-10 150873 Date 5-14-03 0.
1 2 3 4 5 6 6.4 7 8
Mezzanine Crawl Space Floor N A" Snil Samne Lcnantinsc
/U VA-FS-04 6.75 6
5 I JVA-FS-05 15 UVAF -03 4
7 3
2 1 UVIA-FS- 01 (j) UVA-FS-02 1 _ . _ Survey #-UVA-FS-01 1 Date 5-15-03 0
1 2 3 4 5 6 6.4
_ ___ __ C(
C C (
UVAP__ _ _ _ _
Radiological Survey Form Location: IRW"p#W Survey S Survey Type: Page l of 3 Reactor Room Drain Line I UVA-FS-012 Final Status Survey Comments: Surveyed y I Date: Instrument Serial Cal. Due Probe Areal Serial Cal. Due a Elf. p Etf. 0g.
M 0 Bkg aL Final Status Survey of drainpgipe from _ ___- -___ - ___
the source room to the track pit. tBobby leigh !05/19103 M.2221 172035 4/101004 49.0n/a X339 110121003 n/a 0.0135 Wenl n/a n/a n/a Final Status Survey Addendum 002 [
Surley Unit 30 j Reviewed B.
f-ran05/20/03 I_ ___
t _ -Date:...L.......
- - -.- +
Key.I () ISmearlxxxtoxy DirectFriski Z*,i sample B.-eta dose rate in mRac/h I -X-X-l Boundary I SOP Step OftPad W'Y cn' V- Generaldoserate jl~oert Smears__________ eta Scan _____Static Counts Gross CPM DPMIIO0cm' I GrossCPM IAudible uotsperMlnuteI OPM/lO0crn No ag 0 1 No p yes/no pass/fall No. unsn 11195I0 NJt IP ____________
I1 67 52 1 111 1245 I I Entranceto pipe _ _ _ _ _ _ _ _ _ _ _ _
8 82 42 2370 1220 1 I __ _ loot__
103 64 25931 1381 I fe
_ _14987
_ 73 1482 1326 I i l3feetI I I 1 62 431 14 l feet I i I 5 07 5 23 15feetI i 7l2 6 8 37 16 feet / I
_18 82 65 12593 1391 9 lfeet III_8__9 2148 14_4Io feet_ _ _ _ _ _ I
__12___9__44_164 11feet I 213 65 65 0 1391 I I 12feet I 22 104 88 11852 16193 4 c i fEetetin I I I I 3 784 582 1481 1531I S c 14efeenot enIceI I I 1I9 6 222 10 1 etII I
. -4 -4.-
-4
-4.. -
Room G022 Drain Pipes Survey # UVA-FS-012 Meter # L2221 172035 Probe # 491-30 X339 Beta scan Readings in CPM Date 5-1-03 Track Pit c c (
( (
UVAP wj Radiological Survey Form Location: RWP#iWP Survey # Survey Type: Page 3 of 3 Nuclear Reactor Facility Inside IWUA-FS4012A Final Status Survey Comments: Surveyed By. I Date: Insument Serial i Cal. Due Probe Area Serial S Cal. Due et Elf. B Etf a Bkg. p Bkg a L. p 8t.
Final Status Survey of drains fromn the 0 21 jkg-m CPM, Key-ll 0 ImCPM sSmeaqxxxtoxx=Direct Pnsk I l-rafl Rovlewed By.
Myers E=airsample IlDt B IsbetadoseratelnmRad/i1
-Z1 1 I -X-X-aBoundary SOP aStepOftPad 02_s-Ix/y-contacV12adoserate #a IGeneratdoserate Smears Alpha/B ta Scan Static Counts Gross CPM DPM/100cm' Gross CPM Audible Cots per Minute DPM1100cm' No. a_ ao p R. p yes/no passtfail o. Unsh Shlelded 7Not __ i i _
- 13 255-280 no pass 13 268 288 -83 149 i 1 Swab thur length of pipe i I
_~
I___
_~~~
__I___IT_
I ~ , _I i_ _;
___________ _ l I I ! I
_______ _________________ I . _____I _
_1 ___.____I_'I__II__,_ I . I,
=___=___ _____ I . 1 I
=_____ ___=____I____IIi_ iI-_' I I
=____ =__._=_II__IIiii I I _______
__ ._ _ _ _ _ I _ _ _ _ _ _I _ _ _ I, _ _ _ , . ,
=____ =__ I_____I_____ I ,__.__,
=_____________I_ 'i ii ____
= .I II I ___________,______
__.___= I r_____ I I-
=______ _II__II__'ii_____ I
= = =_1________t _ I
_~~ ~
_________II__I___, , I
_~~~ ___ _ It
_..I . II _______ I Ii i' i ,
_- _- _- _ __ - -- I I I Il
( ( (
UVAP 0 Radiological Survey Form IRWPIWP lSurvey4 l SurveyType Page I of13 Location, Nuclear Reactor Inside _
- UVA-FS-013 j Final Status Survey o Comments: S` Date: Instrument SelIal 4 Cal. Due Prob Area Serlal x Cal. Due B Elff. _ Max 8 Bkg Le aMStatusStavey nG0iliiCe Thompson 0512E3 Tesrelec 64052 41i6n204 nra na nha Ws - na _
Surve.y...t 14__ Jason Strand S0n7t3 M-2221 103942 3Q7/2004 43-68 126 160791 3Q7Q204 0.109 1 343 004 Brad Myers Bdan O5s7)03 M.2221 172051 4Qnco4 43.37 430 161367 4/2094 I 0.109 F
. . . Date M-2221 184010 Y242003 44.10 na 150873 3/24Q003 nh _
K I e ( *SrnearmlowxDirectFnst &e-ir ssm ae E .beta dose rate n mRadci -X-X. - Bounday SOP. Stap OfRPad _ !-cantacU/12 dose rate N- Genraldose rat Smears I Static CountB I Coordinates Gross CPM oPMJ1rm' lcnshlShleded DPM/tlOcm' _ ___
No. a i a I No. CPM Net Le No. North East Elevation I See _ 1385 333 379 310 1 0 1.25 3 2 dI 22AIL257 224 240 254 2 0 0 1 3 Report_ 3 307 2639 27 278 3 0 2.5 1 4 4 327 280 342 284 4 1 0 1.25 5 5 335 323 87 305 5 3 0 2.5 5
8 6389 274 837 281 6 3 0 0 7 i 332 286 335 287 7 5 I 0 125 8 433 332 735 309 8 1 1.25 0 9 98 422 331 663 309 9 3 2.5 0 10 10 389 332 415 309 10 5 125 0 11 11 274 294 .146 291 11 1 3.1 0.75 12 12 315 315 0 301 12 1 3.1 2.75 13 13 26D 243 124 264 13 3 3.1 1.5 14 _ 14 286 284 15 286 14 5 3.1 0.75 15 15 329 312 124 300 15 5 3.1 2.75 16 16 445 331 830 309 16 5.6 0 1.5 17 17 327 285 306 286 17 56 2Z5 1.5 16a Ii18 50 l 364 1.048 324 168 0.5 125 3.1 19 ___ 19 413 303 601 295 19 2.5 a 3.1 20 __ _20 554 409 1.0666 33 2 2.5 2.5 3.1 1 21 21 439 391 349 335 21 45 1.25 3.1 QC CC 469 1 364 765 324 CC 4 5 1.25 3.1 Form SEC-RP-21.2 Rev.0
Room GO 18 East wall 1 meter Grid N 4 E=3.6 3.1 260-330 260-330 250-320 280-350 300-390 300-400 3
260-330 260-330 250-320 280-350 300-390 300-400 2
220-330 200-300 220-280 200-290 300-390 300-360 Beta Scan 1
Readings in CPM Denotes smear location 0 and static counts 220-330 220-340 220-300 215-310 230-290 250-300 Survey #UVA-FS-013 1 0 5.6 5 4 3 2 Meter # 103942 L2221 Probe # 160790 43-68 Date 5-27-03
( (
C c Room GO 18 North Wall 1 meter Grid N = 5.6 3.1 400-540 400-550 430-560 420-530 3
400-540 400-550 430-560 420-530 2
L400-500 270-330 400-520 400-520 Beta Scan ()
Readings in CPM Denotes smear location 0 and static counts 1 380-480 260-320 330-500 400-500 Survey #-UVA-FS-013 3 3.6 0 1 2 Meter # 103942 L2221 Probe # 160790 43-68 Date 5-27-03 B
Room GO 18 South Wall 1 meter Grid N=O 3.1 300-380 320-420 270-400 300-400 3
300-380 320-420 270-400 300-400 2
260-320 280-380 260-380 290-360 Beta Scan Readings in CPM Denotes smear location And static counts 0 30) -(I 1 220-310 220-310 200-300 200-300 Counter Survey #UVA-FS-013 Meter# 103942 L2221 3.6 3 2 1 0 Probe# 160790 43-68 Date 5-27-03 -q
( ( (
( ( (
Room GO 18 West Wall 1 meter Grid E=O 3.1 320-450 300-430 300-400 350-450 400-500 300-450
.3 320-450 300-430 300-400 5 350-450 400-500 300-450 2
300-410 300-380 300-380 260-400 260-320 400-520 N
I Beta Scan Readings in CPM 380-300-380 280-380 300-410 230-300 220-320 410 Denotes smear location and static counts 0 Counter 0
1 2 3 4 5 5.6 Survey# UVA-FS-013 Meter # 103942 L2221 Probe X 160790 43-68 0 Date 5-27-03
Room GO 18 Ceiling 1 meter Grid Z=3.1 5.6 400-500 410-530 400-480 400-480 5
400-500 440-570 410-540 400-520 4
400-500 400-500 420-550 400-520 N 3 I 2
(
375-475 375-475 350-460 400-500 Beta Scan 390-500 400-520 410-520 400-520 Readings in CPM Denotes smear location and static counts 0 1 400-5 10 420-530 400-500 400-500 Survey # UVA-FS-013 Meter# 103942 L2221 Probe# 160790 43-68 Date 5-27-03 0 1 2 3 3.6
( ( (
- ( (
Room GO 18 East wall 1 meter Grid E=3.6 3.1
.I , -I I I I L14100-150 3
_ ~1410 0-15200X 2
1 12800-130 Gamma Scan Readings in CPM I
<712700-13 400 1 gtoo Survey 3 UVA-FS-013 Meter# 184010 L2221 1 0 5.6 5 4 3 2 Probe# 150873 44-10 Date 5-21-03
Room GO 18 Floor 1 meter Grid Z=o 5.6 5
4 3
2 Gamma Scan Readings in CPM l
Survey # UVA-FS-013 Meter# 184010 L2221 Probe# 150873 44-10 Date 5-21-03 0 1 2 3
( ( (
( (.
Room G018 Floor 1 meter Grid 5.6 i AL Ak A 1100-1150 5
nio)
N A 4 300-400 t X 1050- 1075-11,75 1200 275-375 1050- 1000- 950-122 11,50 1J1QO 3 4- 4 I-A_
Beta Scan 1075- 1050-Readings in CPM 1225 1175 2
Survey # UVA-FS-013 1 8_.-
__ I Meter# 172051 L2221 Probe # 161367 43-37 350-450 275-400 300-400 300-400 Meter# 103942 L2221 Probe # 160790 43-68 Date 5-27-03 0 1 2 3 3.6
Room GO18 North Wall 1 meter Grid N=5.6 I ~I 1 3.1 1 14900-16100 ae=
3 v I 1-
~14900-16100 2
Gamma Scan 1 122000144800 Readings in CPM I
12800-14200 1 Survey # UVA-FS-013 Meter# 184010 L2221 Prone# 150873 44-10 0 1 2 3 3.6 Date 5-21-03 E
(. ( (
( ( (
Room GO18 West Wall 1 meter Grid E= 3.6 3.1 I I 13600-15100 3 N 13600-15100
-_j I II1-2 11700-12400 I I 170 Gamma Scan Readings in CPM 11700-12200 11000-11700 12200 0
_ _ _ [ _ _ _ _ _ __ _ _ _
1 2 3 4 5 5.6 Survey # UVA-FS-013 Meter# 184010 L2221 Probe #t150873 44-10 Date 5-21-03
Room GO 18 South Wall 1 meter Grid N=O 1 '04 3.1 12200-14800 3
.- 1.
12200-14800 1 2
12700-13100 Gamma Scan Readings in CPM 1 10500-11200 Survey # UVA-FS-013 Meter # 184010 L2221 3.6 3 2 1 0 Probe # 150873 44- 10 Date 5-21-03
( (
( (
Room G018 Ceiling 1 meter Grid Z=3.1 5.6 N 5 4
3 2
Gamma Scan Readings in CPM 1
Survey # UVA-FS-013 Meter# 184010 L2221 Probe # 150873 44-10 Date 5-21-03 0o 1 2 3 3.6
( ( (C UVAP Radiological Survey Form Location: RWPIWP Survy# SueType: Page I of 9 Nuclear Reactor Inside I UVA-FS-014 Final Status Surve Comments: S De Instrument ivedBy Serial a Cal. Due ProbejArea Serial Cal Due I a Elf. I Moax Bkg Lc FinalStatus Srey.RadrPo itnd Alice Thompson 5 3 Tennelec 64052 411612004 nha nta l nh nha nh _
Surve _ason Jrit4 Strand O5Q2f3 M-2221 103942 312712004 4348 1126 160790 327004 0.109 316 FBnal6atu Suvey Brad Myers 05Q8fO3 M-2221 172051 42Q004 43.37 430 161367 4Q22004 0.109 lF . . .wed8 Dae O5QI-ft M.2221 184010 l 3124Q004 44-101nta 150873 3t24Q2004 nta ILrank Myers Kw. -*Srneare=1xxx-DirectFns A-awsample 8betadoeerate n mRadih X-X_ *Boundary SOP StepOffPad nctawldi Z-to" erate f Gereraldoserai Smes Static Count D I Coordinates GrossCPM DPMtlOOmcr Unsh/Shlelded DPM fOOcrn I No. a a 0 No. CPM Net ILe NI north east elevation I See _ ¶ 365 1 255 8601 271 1 1 1 0 .0.5 22lch _ 2 363 249 830 268 2 3.5 0 .2 3Reort 3 295 208 633 245 3 5 1 .3.5 4 4 352 204 1.078 242 4 1 0 -3.5 5 5 335 237 714 261 5 3.5 0 .5
-t6 6 344 237 779 261 6 5 25 .1 7 7 326 229 706 257 7 3.5 I 3.7 .1 8 8 326 346 .146 316 8 1 3.7 -2.5 9 9 324 250 539 268 9 3.5 3.7 .4 10 10 361 216 1.056 249 10 1 3.7 .5.5 11 11 345 202 1,041 241 11 1 0 46.5 12 12 294 221 532 252 12 5 2.5 .6 13 13 318 210 786 246 13 3.5 3.7 -7 14 14 380 282 714 285 14 3.5 1 7.35 15 15 434 271 1.187 279 15 1 2.5 -7.35 QC QCC 426 1 271 1.129 279 16 1 2.5 .7.35 Form SEC-RP-21.2 Rev.0
Reactor Pool West Wall 1 meter grid E=O 0
400-700 1 310-460 330-470 315-450 330-430
-1 400-800 320-440 340-460 320-400 330-430 N -2 400-900 320-420 330-400 330-390 320-420
-3 300-800 4 300-400 320-380 310-400 300-400
-4 Beta Scan 400-600 290-410 300-400 300-400 300-410 Readings in CPM Denotes smear location and Q static counts -5 300-600 320-400 320-420 330-400 340-420
-6 280-600 1 300-370 320-430 260-380 340-410 Survey # UVA-FS-014 Meter# 103942 L2221 -7 Probe# 160790 43-68 300-400 1280-360 310-350 340-400 360-425 Date 5-28-03 -7.35 0 1 2 3 4 4.7
( (
( (
Rx pool North Wall 1 meter grid N=4.7 0
300-400 310-420 315-400 300-400
-1 350-410 340-400 340-410 360-440
-2 340-420 330-400 320-400 350-440
-3 290-400 3290-390 290-350 300-360
-4 300-350 290-370 390-390 300-380
-5 Beta Scan Readings in CPM Denotes smear location and 0 300-350 280-380 280-380 290-370 static counts -6 290-340 340-400 310-430 300-390 Survey # UVA-FS-014 -7 Meter# 103942 L2221 290-370 370-430 320-415 360-450 Probe # 160790 43-68 Date 5-28-03 -7.35 0 1 2 3 3.7
Reactor Pool Floor North side 1 meter grid Z=o 4.7 4
N 3
Beta Scan 2 Readings in CPM I
Survey # UVA-FS-014 Meter# 172051 L2221 Probe # 161367 43-37 Meter# 103942 L2221 Probe # 160790 43-68 0 Date 5-28-03 1 2 3 3.7 C c
( C Reactor Pool West Wall 1 meter grid E=O 0
_I II 1 10500-12500
-1
~10000-11200
-2 -. I I E- 9600-11000
-3 -1 I I l-
< ~9600-10300
-4
- 9700-10400
-5 Gamma Scan < 8800-9600 Readings in CPM -6 Il I I I '
-, I I I Survey # UVA-FS-014 ] 10000-10600>
Meter #184010 L2221 - l I 1 Probe # 150873 44-10 -7 I I Date 5-27-03 10900-11600 .
-7.35
- 0 1 2 3 4 4.7
Reactor Pool Floor North side 1 meter grid Z=o 4.7 4
N 3 -
I 10300 10700-11000 11200 10600-10400 .11000 10900 2
1 103 00- 10200- 10300- 10300-10900 10500 10600 10600 Gamma Scan Readings in CPM 0 1 2 3 3.7 Survey # UVA-FS-014 Meter# 184010 L2221 Probe# 150873 44-10 Date 5-27-03
( (. (
( (.
Rx pool North Wall 1 meter grid N =4.7 0
I I F1 10400-11400
-1 10200-10800
-2 9600-10500
-3 E
'I I 9500-10200 I -
-4 1 9300-10300
-5 8800-9800 Gamma Scan Readings in CPM -6 1 10500-11000 Survey # UVA-FS-014 -7 Meter# 184010 L2221 I I 1 Probe # 150873 44-10 11000-11500 Date 5-27-03
-7.35 0 1 2 3 3.7
Reactor Pool East Wall 1 meter grid E = 3.7 I I I -1 0 10800-12000
.I I I -1 I I I
'S:--10000-12000
-- ETA -2 1 1 1 9800-11500 I I I 1 -3
/11I
< 9500-11600
-4 1 ~9500-10300 IJ I I X -5 Gamma Scan II I1 Readings in CPM -6 Survey # UVA-FS-014 10800-11600 Meter #184010 L2221 I I I l 1 -7 Probe # 150873 44-10 Date 5-27-03 10500-11200 I I i -7.35 4.7 4 3 2 1 0
( c (
C (
Reactor Pool East Wall 1 meter grid E=3.7 0
320-400 315-390 315-400 310-410 350-1000 O -1 330-410 320-400 320-410 320-430 400-900 4-N -2 300-390 290-350 290-370 310-400 8400-800
-3 310-400 310-410 300-390 340-440 400-800
-4 310-400 290-370 280-380 290-400 300-600 Beta Scan -5 Readings in CPM 310-410 280-380 300-380 300-400 300-800 Denotes smear location and 0 static counts
-6 Survey # UVA-FS-014 300-400 280-370 300-380 320-375 290-700 Meter # 103942 L2221 Probe # 160790 43-68 -7 Date 5-28-03 300-340 300-380 330-380 320-400 290-330
-7.35 4.7 4 3 2 I 0
( ( (
UVAP Radiological Survey Form LoNatRonc ____age_ RWPoWP _ SuInside* Stau St8 Nuclear Reactor Inside I UVAFS-015 Final Status Surve Comments: Stre -e Date Inst ument Serattt# Cal. Dw Prob Aa Sertai Cal. Due r; Eff. 15El i tkg l pkg a L. p Fnw StatusswvydRea.ctrPdSauf end Alice Thompson OS93 Temrseic 64052 4/162004 nWa nS nVa n/a W nh_ nha , nta WS fits IJason Strand 0S2603 M-2221 103942 3271004 43-68 126 160790 3/27lZ4 nt 0 109 a nhW nta nta
......................... _ 10 4 3 4 j
U.4-.A Bvs D.w t1 M.7222
... V-I lRAfll Vz -- s I A/M
-V I4 I.U".in-s
- _S_
I 2 I. _tS873 4t2 r414/A I r00 I I n/a I n/a I nta I nW bKgintM, L. in CMi -ranKMyers I II I I I
&a-Weamtn B -beta coserata anmRadth .. X..X-
- Boun dary SOP
- 51eoOftP Static Count T Coorfinates F
_ Gross CPMj DPMtltcmW' I DPtMwtt cm' I No se I I a 1 P ~Nc 1 249 1 502 north I
- 1 east 1.5
- levatIon e
0 318 2 AM I 2 414 241 1260 t 1 .5 05 _ I 3 Reportj3 3349 l 228 __ 88 3 2 l -25 4 4 494 260 1704 45 0-5 4 6 430 239 j _ 568 t 6 61 350 243 77 6 1 0 1 5.5 442 245 1.434 11 71 -0.75 3 -2.5
_ _ 346 234 815 81 41 0.5 3.2 -2 242 32 .5 I 345 37 t 1 328 224 757 3.7 t 1 412 284 1 1932 -0.5 0.5 .7 1 359 244 837 11 131 2 3.7 -6.5 221 1.427 I5 40.5 3 .7.35 Ir 2 1.5 .7.35 a 1.5 .7.35
=
=
I -
=
I IJ I I I I I I Form SEC.RP-21.2 Rav.0
Reactor Pool East Wall 1 meter grid E = 3.7 0
11000-11800
-1 N "4 10600-11200
-2 1 ~10400-10900 _
-3 10000-10600
-4 10700-11500 Gamma Scan -5 Readings in CPM 1 ~9800-12000 Survey # UVA-FS-015 -6 Meter# 184010 L2221 10800-11700 Probe# 150873 44-10 Date 5-27-03 -7 11300-12500
-7.35 4 3 2 1 0 -1
( C (
( (
Reactor Pool West Wall 1 meter grid E=O 0
F 114000-11000
-1 9510500-11200
-P N -2 1 1 11 970100 I 10000-11000
-3 I I 1I 9700-11000 1
-4 I II F 9500-11500 -
-5 I I I Gamma Scan Il I Readings in CPM c::Q_10000-12200
-6 *r I I' Survey # UVA-FS-015 I 1 Meter# 184010 L2221 1 12000-13500 Probe# 150873 44-10 1 Date 5-27-03 -7 i I12000-12900
-7.35 I I I
-1 0 1 2 3 4
Reactor Pool Floor South Side 1 meter grid Z=o 4
3 N
2 1
Gamma Scan Readings in CPM 0 Survey # UVA-FS-015 Meter# 184010 L2221 Probe # 150873 44-10 -1 1 2 3 3.7 Date 5-27-03
( ( (
( (
Rx pool South Wall 1 meter grid N=-1 0
-1 Gamma Scan Readings in CPM
-2 E 4- -3
-4
-5 Survey # UVA-FS-015 Meter # 184010 L2221 -6 Probe # 150873 44-10 Date 5-28-03
-7
-7.35 3.7 3 2 1 0
Reactor Pool West Wall 1 meter grid E=O 0
320-440 270-400 300-400 310-390 280-400
-1 2_
330-460 300-440 310-410 315-400 320-440
-2 370-460 315-440 320-4110 3 9315-440 320-400
-3 370-470 310-500 310-410 320-400 330-430
-4 Beta Scan Readings in CPM 370-600 300-500 300-400 310-400 300-415 o denotes smear and static count locations. -5 390-470 390-470 300-400 6 3310-420 300-400 Survey # UVA-FS-015 Meter # 103942 L2221
-6 Probe# 160790 43-68 300-440 330-430 360-420 340-390 300-440 Date 5-28-03
-7 320-420 300-470 400-575 360-400 330-430
-7.35
-1 0 1 2 3 4
( ( (
( (
Rx pool South Wall 1 meter grid N=-1 0
320-420 320-430 330-420 320-400
-1 330-430 330-425 330-400 340-460
-2 370-450 7 370-450 390-450 370-460 E 4- -3 370-470 370-470 370-500 380-450
-4 Beta Scan Readings in CPM 350-450 360-470 370-480 370-600 O denotes smear and static count -5 locations.
350-450 350-450 390-470 390-470
-6 Survey # UVA-FS-015 Meter# 184010 Probe # 150873 320-400 340-370 390-470 300-440 Date 5-28-03 -7 350-430 300-400 280-400 330-420
-7.35 3.7 3 2 1 0
Reactor Pool East Wall 1 meter grid E=3.7 0
300-430 330-430 330-440 330-400 320-440
-1 300-410 310-400 310-400 300-410 33
-2 N 300-410 320-400 320-400 310-410 370-460
-3 300-400 320-440 i 310-450 300-450 370-470
-4 310-400 310-410 310-410 310-400 370-480 Beta Scan Readings in CPM -5 0 denotes smear and 300-400 350-450 310-400 310-400 310-400 static count locations.
-6 Survey # UVA-FS-015 310-380 280-350 13 300-380 315-370 320-400 Meter # 103942 L2221 -7 Probe# 160790 43-68 Date 52803 300-375 300-350 1 280-350 330-375 350-430
-7.35 4 3 2 1 0 -1
( ( (
( ( (
UVAP Radiological Survey Form +/-1' Location: RRWPIWP Survey# jSuvy Type: SPag 2 of 13 Nuclear Reactor Inside IUVA-FS-016 Final Status Survey Comments: ] Date: instrument Seriala Cal. Due Prob Areaser SeaiC Cal. Oue _ E. __ Mr mx x ktkgiS FndStatu&Su^reyoRoomMCO8Cl5Ss 1 lAliCeThOmpSOfl 06t03n Tennelec 64052 4/182004 na nV/ nrh nWe [ n_a _
LowerUwalnsa ndiom.Sveytlng 7 obby Leigh M2221 187752 1m16t204 4381 1261 160700O 1/162,004 00655 571
,rrO04 _ __ _ __ l M.2221 184010 3c24r2004 441i rth 150873 324/2004 nVar Revbwe R1v Dttt i M.22?1 t7203 4110t2X4 491.301 nW X339 I nha e-___________________ . . .... L~ e s 6 I -- --- 1w --- -- - - I -_ I _
Ke I h m-ImD)=r *-ore eD Fnsrtk 'M. B Ebeta dose rate in mRadhl -XX-
- Boin ary S rate yontactl2 jdose #. te lradose rat
.. = . . . _ . =,_. a qme
-. J-------;--
Sqtatfc Coun
.B
--. i-.
Conadinates # 20 was scan ana static count on massitnn pipe swaD
_ GrossNCPM DPMttOOcm lU LnshtSheldtdl OPMttOc"?
No a IB a Ii No Ne No'PM Lc *ast elevation t1 see I -1 - I t 5 3241 2857 St2 310 1 2198 501 0 467 346 I 1477 1 529 IL 0.5 0 125 31Report_ 334 1 12 520 05 125 I 0.1 335 531 0.8 3.75 0.1 386 403 1 .208 571 374 354 1 244 535 304 301 1 37 1 494 11 2.5 0.8 272 1.050 469 45 0 125 358 125 i6
.37 537 4.5 I III 98 3.75 0 I 121 468 1 343 126" 02 0 362 1 376 1 .171 552 2.5 0 I 462 1 353 1.331 535 I1 141 6.5 42
._, 409 310 1209 I 501 1i 151 7.8 125 0.75
.244 492 7.8 3.75 0.75 354 4 1 2 1 0 IC oc 357 1 318 501 4 124- 0 396 1 320 1 928 27 3.9 0.4 46S8 331 1 1.873 518 11n/al n/a nA n/a
. I _ .1 eassien I apeSwab 20 2218 361 122674 I d; n n/a n/a 0.9 2310 344] 24,005 2429 1 346 125.433 529 0.8 09
_M_ 2463 1 375 I 25.4951 551 IOC 8 0.9 318 I 647 507 -1231 4 0 'Ioor Drain Uncovered I
=
==
_=
_ . _ _1 I. .
FormnSECARP-21.2 Rev.0
UVAP Radiological Survey Form Location: IRWP#/WP Survey Survey Type: Page 1 of 13 Nuclear Reactor Facility In ide IUVA-FS-016,A Final Status Survey I Commentsl Surv yedBy; Date: Instrument Seriul# Probl Area Serial# Cal oue a Etffl pEff a Bkg I L -L.
SrveyOlr~a~inpipe from M008 tO___
CAVALiER Rx room _ Bobby Leigh t J63 6 M 2221 172035 411t2004 j491t3 r X339 n n/a ta n ta nta na nta We nta Final Status Survey AdedttOi Ret By. Detl _
------- ersnkV -, 06t050(3 _= -= =
K i 0 *Smear xco- DrectFnsl Aair samE_ _betadose reitemRad/h .X-X *Boundary SOP Step0f Pad dose rate' ont-ntawtjl2 t- General dose rat Sm_ _ __h__ _ta I Scrtn Static Counts GrossCPM DPMll1ocm' GrossCPM Audible Counts per Minute DPMt100cm' N°. a a P No. p ye"o paibil No. Unsh Shielde . _ _ _ _ __P_ _
10 38 59 n/aOpenw'g Room MOOS 2 43 25 l1334 W 6 rndhes I 30 3j 26 296 nitaes We12 4 30 32 l 148 lnta 18 hirhes 5 37 24 963 nta 24 Inches I i 42 28 i 037 I nta 30 htchett i 7j 30 27 2 ta 36hres I81 47 30 l1260 l 42 riches 9 48 31 l1260 na 48 intes 10 39 28 l815 lnta 54 hrces It 38 25 I 963 Ina 60 intes i i ii iI i 12i 37 24 i963 iWnae 66 inches 1i31 t4 32 i 9 I r 72 idhes
'14___37__6 ____We 78 edeNe Is 42 34 593 lna 84 rndies i 42 24 1334 I na_ 90ihdeS
17 29 27 148 rna 96 indies l
18l l 34 28 l445 lExit in CAVALIER I I - I-- I I 1 1 = I I tI--
C FoxrmSEi('~ ' RevO0 e
I
( ( (7 Room M008 North wall 1 meter grid N=7.85 3
2 356-442 341-406 302-356 244-407 1
352-403 386-437 267-383 243-441 0 1 2 3 4 4.2 Survey # UVA-FS-016 Beta Scan Meter# L2221 187752 Readings in CPM Probe# 43-68 160700 0 Denotes smear and Date 6-02-03 static count locations
Room M-008 East wall 1 meter grid E=4.1 3
2 362-461 370-480 419-554 412-526 374-458 330-424 288-420 343-516 1
4)
(-41 47l 330-461 343-436 428-553 407-551 262-404 226-349 283-326 242-319 0
7.8~s 7 6 5 4 3 2 1 0 Drain Survey# UVA-FS-016 Beta Scan Meter # L2221 187752 Readings in CPM Probe # 43-68 160700 O Denotes smear and Date 6-02-03 static count locations
( ( (
( (
Room M-008 South wall 1 meter grid N=O 3
2 446-590 273-487 299-494 453-577 0 0 284-349 264-344 283-360 254-333 1 4.1 4 3 2 I 0 Survey# UVA-FS-016 Beta Scan Meter # L2221 187752 Readings in CPM Probe # 43-68 160700 0 Denotes smear and Date 6-02-03 static count locations
Room M-008 West wall 1 meter grid E0 3
I 2
441-530 312-553 296-396 397-498 329-481 281-476 369-482 352-477 0 0 1
317-403 245-346 262-309 248-342 289-366 266-345 246-334 296-337
__ 0 _ __
0 1 2 3 4 5 6 7 7.85 Survey # UVA-FS-016 Beta Scan Meter # L2221 187752 Readings in CPM Probe # 43-68 160700 o Denotes smear and static count Date 6-3-03 locations
( (
( ( (
Static counts taken every 6 inches Room M009 Room M008 J
Approximately 10 feet CAVALIER Room Survey # UVA-FS-016 Beta Scan Masslinn swab from 19 to 18 scanned 254-1116 CPM Meter # L2221 187752 Readings in CPM Highest direct on swab 361 cpm shielded/ 2218 cpm unshielded Probe # 43-68 160700 o denotes smear and static count locations
Room M009 North Wall 1 meter grid N=7.85 3
2 10700- 10700- 10700- 10300-12300 12 00 12300 12800 1
0 1 2 3 4 4.1 Survey # UVA-FS-0 16 Gamma Scan Meter# L2221 184010 Readings in CPM Probe# 44-10 150873 Date 6-02-03
( ( (
a
( (
Room M-008 East wall 1 meter grid E=4.1 3
2 11500- 11400- 11500- 11300- 9600- 8500- 9800- 9100-12 00 12900 13000 127100 .12 00 10800 107100 13 00 1
0 7.85 7 6 5 4 3 2 I 0 Survey # UVA-FS-016 Gamma scan Meterft L2221 184010 Readings in CPM Probed 44-10 150873 Date 6-02-03
Room M-008 South wall 1 meter grid N=O 10000- 9300- 10000- 9700- 3 2
10000- 9300- 10000- 9700-E 4- 13 00 13500 14 00 14500 1
I 4.1 4 3 2 1 0 Survey # UVA-FS-016 Gamma Scan Meter#L2221 184010 Readings in CPM Probe# 44-10 150873 Date 6-02-03
( C C
( (
Room M-008 West wall 1 meter grid E=0 3
2 10900- 10700- 11600- 10100- 9200- 8900- 9400- 9200-14500 133 00 13 00 12E 00 11500 11700 12700 1 400 1
0 1 2 3 4 5 6 7 7.85 Survey # UVA-FS-016 Gamma Scan Meter # L2221 184010 Readings in CPM Probe # 44-10 150873 Date 6-02-03
7.85 M-008 Floor 1 meter grid AL AL Z=o A IL 7
6 Y 5 1C:00-15 00 105C00 11 00 98 00-12500 8E 00-11200 4
3
_1- __ _'-
Gamma Scan Readings in CPM 2 Survey # UVA-FS-016 1 I Io I Meter # L2221 184010 Probe # 44-10 150873 Date 6-02-03 I I I ,
0 1
& 3 4 4.1
( ( (
7.85 M-008 Floor 1 meter grid Z=o 327-4 329-398 312-408 303-351 7
285- 66 296-391 ( 324-402 294-380 6
312-416 273- 23 287-373 319-398 5
264-380 279-39 317-5 58 284-374 IC, _,-rain 4
302-3 6 302-360 267-1C 04 3 ,IA QnA Beta Scan 360- 82 328-553 ( 264-38 Readings in CPM 325-374 0 Denotes smear 2 and static count locations 327-402 296-538 272-356 275-34 Survey # UVA-FS-016 1
Meter # L2221 187752 Probe# 43-68 160700 Date 6-2-03 X (22 312-476 324-447 284-231 325-2340 0 0 1 2 3 4 4.1
( ( ~(. (
UVAP Radiological Survey Form Location, IRWP/WP S rwey 0SOTyp: Page I of 7 UVA-FS-017 Final Status e aurv o Comments: Burv Date: Instrument Serial# Cal. Due Prob Area Seroal4 Cal. Due _ Mx1 mff. BkgLc Fnal stab SUMwy Lower 2 mee d v Alice ThomDp5on 0603 Ternelec 64052 40l6d2004 nVa nVn We nha 9
.teReadmrn Jason Strand 06210 M-2221 103942 3i27r2004 43-6C 1261 160790 3r27f200t4 0109 340 SwveyLnit13 'BradMyers 0 M-2221 184010 3r24i2003 44-10 nh 150873 3124J2003 = nh Fnal S1alin &aveyAd C 0IR . lDt:..
.5 --- II" Stati'sCiniv3n Key-,i , Smear xID)=cDirec ssample aw B
- Bouday SOP Ste 'dose rate
- General dose ra Smears Static Countl iGroas CPM I DPWtO2em0 UnshShleldled DPMlOOcn' Net 21 Lc IINo.1 Linear Elevation li-I ae II i I C. 1 - 318 11 0 1.5 2iiz L IZI 315 0 321 1.5 3ARRepof 414 356 422 320 0 E~1 349 369 i .146 326 11 SI 10 15 0
6 = 352 58 11 318 11 61 12.5
=7 361 337 311 I 15 1.5 0
293 I 9 380 329 293 597 295 1 248 11 291 225 =t 1.5
= 387 3511 1 326 337 444 30S 11Il 121 25 27S5 0 405 1 356 1.5 415 m 298 0 392 I 361 322 II 151 35 lS 36 316 11 161 37.5 0 40 1.5 0
412 374 1.5 402 i 51 413 401 87 340 410 337 532 311 IOC I 50
=
=
l l :iz at =
I 1I I It = lb Form SEC.RP.21.2 Rev.0
Reactor Containment Wall 1 meter grid 2
275-380 250-350 260-340 270-340 310-4204 260-375 1 360-430 350-410 340-410 300-380 1
250-375 250-330 230-320 260-340 350-430 330-425 340-420 300-390 350-430 310-400 0
20 21 22 23 24 25 26 27 28 29 30 2
300-390 290-380 290-380 350-420 330-420 320-400 330-420 300-370 330-390 300-3904 1
320-420 320-400 350-420 280-400 340-440 340-480 330-490 300-430 350-460 300-400 0 l l A A A J..............(
30 31 32 33 34 35 36 37 38 39 40 Survey XUVA-FS-017 Beta Scan Meter # L2221 103942 Readings in CPM Probe # 43-68 160790 o Denotes smear and static Date6-02-03 count locations
( (
( (
Reactor Containment Wall 1 meter grid 2
320-430 300-420 300-400 300-400 300-440 1330-430 300-420 300-410 380-460 330-420 1
320-430 330-450 320-440 320-460 350-450 330-450 320-430 330-450 300-480 300-420 040 41 42 43 44 45 46 47 48 49 50 2
320-430 300-410 qc 1
330410 310-420 0
Survey # UVA-FS-017 Beta scan 50 51 51.3 Meter # L2221 103942 Readings in CPM Probe # 43-68 160790 o denotes smear and Date 6-02-03 static count locations
Reactor Containment Wall 1 meter grid 2
1 11400- 10800- 10900- 13800- 13600- 14100- 14300- 14000- 13900- 14000-12800 11800 11900 14600 14600 14800 14900 14700 15000 14800 0
20 21 22 23 24 25 26 27. 28 29 30 2
14600- 14200- 14500- 14800- 14700- 13800- 13500- 13100- 13000- 13800-1 15400 15600 15400 15600 15900 14500 14200 13800 14400 14600 0
__ 4,,44,,,,
30 31 32 33 34 35 36 37 38 39 40 Survey # UVA-FS-017 Ganuna Scan Meter#L2221 184010 Readings in CPM Probe X44-10 150873 Date 5-29-03
( ( (
( (
Reactor Containment Wall 1 meter grid 2
1 I4 t l4l0l t140 t l l t01470 15000- 15000-15000 15300 15400 15600 15600 15400 15600 15400 15700 15500 040 411 41 1111 41 42 43 41 44 45 46 47 44141 48 49 50 2
1 1500.-
15600 1540(
0 __I4 50 51 51.3 Survey # TVA-FS-017 Gamma scan Meter # L2221 184010 Readings in CPM Probe# 44-10 150873 Date 5-29-03
Reactor Containment Wall 1 meter grid 2
ft 14800- 13500-ft 13500- 13800-t t ft 14000- 14800- 1W5300- I5Z00-ft 14800- 1l5100-1 15700 14600 14600 14500 14900 15700 15800 16400 15800 15700 0 _ _ _ _ _ _ _ _ _ _ 41 _ _ _ _ _ _ __
0 1 2 3 4 5 6 7 8 9 10 2
1 14O 2900 14500O 14700- 14800 JA5 14J0- I 0fl 146 - 14300 15400 14300 LLTS15600 15600 15600 15700 T< 15600 15700 15600 14900
.4 0 10 11 12 13 14 15 16 17 18 19 2:0 Survey # UVA-FS-017 Gamma Scan Meter# L2221 184010 Readings in CPM Probe# 44-10 150873 Date 5-29-03
( ( (
( C (
Reactor Containment Wall 1 meter grid
, . . .I 21
@350-450 300-380 280-400 350-450 350-420 3 300-410 340-430 330-430 330-420 1350-460 4 4 4 4 .4- .5. 1 4 4.
1 330-450 300-380 290-360 330-400 330-440 350-450 320-410 330-450 340-410 300-430 0
0 1 2 3 4 5 6 7 8 9 10 2
350-450 280-380 320-400 300-400 350-450 7 300-400 350-450 330-420 300-400 280-400 1 1 1 11 1.
1 320-410 280-380 300-400 350-450 300-425 300-400 350-450 350-450 320-420 350-450 0 10 11 12 .3 14 15 16 l7 18 19 20 Survey # UVA-FS-017 Beta Scan Meter # L2221 103942 Readings in CPM Probe# 43-68 160790 o denotes smear and Date 6-02-03 static count locations
( ( ~( (
(
UVAP Radiological Survey Form Location: RWPIWP ulS StatusrveyTy":g Nuclear Reactor Inside UVA-FS-018 Final S-tus Surveo Comments: S d By. Date: Instrument Serial# Cal. Due ProbeArea SeriaS Cal. Due l Elf. Maxpi BkgLc Fiasatsn~rxMoo8upperwagtsa lXiic:F Thm n 0604e Terneiee l64052 4/t6il2004 nh l nta I nha l nal nla Crmilis two Bobby Leigh o0vsva M.2221 187752 1/1t62004 1438 t25 1f0700 1116r2004 __- 0.05'i2 SureUnrt38 l __ _ M-2221 1l4010 3/2412004 44.10 nha 150873 l32412004 = nha FnaslStsbjs SiareAd r CB4 Re- -wedBw Datet I I 4-4-4-4 4-t.-I--.t I I dose raie tbetan mRadrn .X-X. ** Boundary SOP
- Sto Off Pad xzy
- contaItl2 dose rate 7. Gewsi dose ra l
Static Count i Coordinates ,second # 6 smear obtained to confirm activity and offsite analysis GrossCPM I DPW/OOcn? II Unsh]Shlelded DPWI00cm' i;;
etevation No a Il O I a I CPM - I . .~ _ -..
_ see I I I I 1 &33 1 3E 21 490 350 1.709 532 3Report 1 3 53t1 366 2015 544 3 0 l 4 2 4 4482 349 1.624 531 4 1 0 2
_ 5550 373 Z161 549 5 1 1 3 6 6 3198 333 34.t92 519 6 1 3 25 7 7 48j 351 1.673 533 7 1 42 2.2 a 8 487 354 1.624 535 8 3 0 3 9 9 584 374 264 550 9 3 2 2.5 10 10 550 353 Z405 535 10 3 I 4 2.5 11 11 558 1 365 Z357 544 II 5 0 2 12 12 572 365 Z527 544 12 5 1 2.5 13 13 593 349 Z279 531 13 5 3 2.5 14 _ 14 469 344 1.526 528 14 5 4.2 2.2 15 l 15 489 374 1.404 550 15 7 0 2.5 16 16 tSO 350 3053 532 16 7 _ 2 2.5 17 _ 17 615 363 3.077 542 17 7 4 2.5 18 18 385 344 501 528 18 6.8 2 2_ 2.5 19 19348 376 *342 552 19 3 _ 2 2.5
_ t ll
-_ - I li8 _
_ _ _ ,~ d,, _
Form SECARP.21.2 Rev.0
Room M-008 East wall 1 meter grid E =4.2 2.5 325-450 419-530 2
14 7 1
0 7.85 7 6 5 4 3 2 1 0 Survey # UUVA-FS-018 Beta Scan Meter # L2221 187752 Readings in CPM Probe # 43-68 160700 o denotes smear and static Date 6-05-03 count location
(. ( (
( (
Room M-008 South wall 1 meter grid N=O 2.5 448-558 398-504' 464-523 2 _ _ Q2 E 4-1 4.2 4 3 2 1 0 Survey # UVA-FS-0 18 Beta Scan Meter # L2221 187752 Readings in CPM Probe # 43-68 160700 o denotes smear and static Date 6-05-03 count locations
Room M-008 West wall 1 meter grid E=0 2.5 333-405 367491 393-492 392-450 3 2 _ I_ I_ I (ji)
I _I
--- N I 1 2 3 4 5 6 7 7.85 0
Survey # UVA-FS-018 Beta Scan Meter # 12221 187752 Readings in CPM Probe 4 43-68 160700 o denotes smear and Date 6-05-03 static count locations
( C (
( (
Room M-008 East wall 1 meter grid E=4.2 11600- 11500-11900 12000 t 4 4 2 1 1 1 4* + + + 4 4 0
7.85 7 6 5 4 3 2 1 0 Survey# UVA-FS-0 18 Gamma Scan Meter # L2221 184010 Readings in CPM Probe # 44-10 150873 Date 6-04-03
Room M-008 South wall 1 meter grid N =0 2.5 12500- 11600- 12500-12900 12800 13900 2
E 1
0 4.2 4 3 2 1.
Survey # UVA-FS-018 Gamma Scan Meter # 12221 184010 Readings in CPM Probe # 44-10 150873 Date 6-04-03
'( (. (
( (
Room M-008 West wall 1 meter grid E=0 2.5 12500- 12100-12900 12800 11000- 11000-I 1son 19)On 2
I 0 I 2 3 4 5 6 7 7.85 Survey # UVA-FS-0 18 Gamma Scan Meter# L2221 184010 Readings in CPM Probe # 44-10 150873 Date 6-04-03
M-008 Ceiling 1 meter grid Z=2..5 7.85 7
113 00- 11200 11700 0 11500-6 r 4 5
11000-11600 11200-11600
.X nVentilation supply 10400-10900 3
10100- 10600-Gamma Scan 12000 11100 Counts in CPM 2
Survey # UVA-FS-018 Meter# L2221 184010 1 _-Ventilation Return Probe # 44-10 150873 Date 6-04-03 11800- 11300-12900 12200 0 2 3 4 4.2 c
( ( (
M-008 Ceiling 1 meter grid 7.85 7
6 N
5 Supply 4
3 Beta Scan 2
Readings in CPM O denotes smear and static count locations Survey # UVA-FS-018 1
Meter # L2221 187752 Probe # 43-68 160700 Date 6-04-03 0
( ( (7 UVAP 0 Radiological Survey Form Location: IRWPIWP JSurvey# lSurveyType Page o/7 Nuclear Reactor Inside UVA-FS-019 Final Status Survey Comments: Data: Instrument[ Se Col#. Due Prob Area SeriaiC Cal. Due _ _Elf.
FnVafSatu Srwyd Rer rOm fiovoeast i son 0605l Ternelec 64052 41612004 nW nha na nht Wn/
Jason Strand Ob M 2221 1094M2 312M204 43-68 126 160790 3r27/2204 0_109 368 SBeyfnit2 rad Myers oe06K5MM 2221 184010 3124/2003 44.10 nS 150873 312412003 FLA I R RoviewSted D M-2221 DSuatyededm004 172051 4t212004 43.37 430 161367 412t2u04 0 109 Frank Mvers__ IN = - _
- lI (U aa *- Urrtrecrnsa. -en sampie tt *beta oowe ate in mtaawn L -A-x - x_ ounday QUr S iep LMtra xiy- contacvlz dose rate a*- "ererat Oe ra Smears Static Count _ CoordInates Gross CPM DPMI0WCm' UnshfShleildd OPfW1ftcm' __i No. a I a No. CPM Net Lc No. North East Elevation I See I 1 06 420 626 348 1 0.5 1 0 2 2 590 396 1.413 338 2 2.5 2.25 0 31Reprt - 3 428 362 481 323 3 2.5 4.75 0 4 4 432 397 255 338 4 4.5 3.5 0 5 i 5 439 358 590 321 5 4.5 6 0 6 6-sf 517 339 11296 312 6 6.5 225 0 7 7 472 , 371 735 327 7 6.5 4.75 0 8 81 416 1 375 299 329 8 685 7.25 0 9 477 1 373 757 328 9 8.5 6 0 10 10t 507 1 390 925 331 10 a.5 35 0 11 tfII 473 374 721 328 11 10.5 2725 0 12 _t12 470 1 383 633 332 12 10.5 4.75 0 13 131 396 1 342 393 314 13 10.5 7.25 0 14 141 345 1 343 15 314 14 1Z5 6 0 15 1 15t 465 1 367 714 325 15 12.5 3.5 0 16 16 457 1f 339 859 312 16 12.5 1 0 17 117 469 324 1.056 305 17 14.5 2.25 0 18 18 408 373 255 328 18 14.5 4.75 0 QC QC 402 348 393 316 QC 14.5 4.75 0 19 Flow drsan 1 19 506 471 255 368 19 6,9 4.75 0 20 FbwrPo aan#2 20 450 327 8^ j 307 201 13. 0 0 21 to_ R~DOr Do 21 449 385 436 333 21 15.6 3 0
=
-a-f-
-a-,-
=
-_ 4 a 4-4-
_ -_ _ _ . i _
Form SEC-RP-21.2 RevO
Reactor Containment East Floor South 1 meter grid z=o 1 1 8 13500- _ C_
-14600 __ 7 6
N I Gamma Scan Readings in CPM Survey # UVA-FS-019 Meter # L2221 184010 Probe # 44-10 150873 Date 6-02-03 2 3 4 5 6 7 8 8.25 SW 0 1
(
(
Reactor Containment East Floor North 1 meter grid
(
Z=o 16.5 13500-_
nnn
_O 4.Ux
, - - 16 12000-
.4 13400 15 12300-13600 14 U-.
13200- _~ 4 -.
14400 4 9 13 N \
I 13300- -
14000 4 4 4 + + + 4.-. 12 13200-14500
.4. 4 4- 4.
11 N
U-.- 4 .4.
14000- 1I 14500 Gamma Scan 10 Readings in CPM
_713700- _\ l 14300 \
Survey # UVA-FS-019 9 Meter#L2221 184010 Probe # 44-10 150873 13700-14400 Date 6-02-03 I 1 8 0 1 2 3 4 5 6 7 8 8.25
Reactor Containment East Floor South 1 meter grid Z=o 8
- 4. 4-0' 4- 1
/ 7 0 0 4 4- 1- 1- 1 6 4 4. 4- 4.
5 N
I -1 1 0
1 R
1, 4
o denotes smear and 3 static count locations
© 0 ZZ Readings in CPM 4 , I. - ,
2 Survey # UVA-FS-0 19 Meter# L2221 103942 Probe# 43-68 167090 1 Date 6-03-03 1
0 4 5 6 7 8 8.25 SW 0 1 2 3
(. ( Q
( (
Reactor Containment East Floor North 1 meter grid Z=o 16.5 16 15
-q--- +
© 4 4 4 X 14 (I
+ 4 4 4 4 4-X 13 N
I 12 II O denotes smear and
© © 0 static count locations 10 Readings in CPM Survey # UVA-FS-0 19 Meter # L2221 103942 Probe # 43-68 160790 Date 6-03-03
]____________L 9
- 1 8 0 1 2 3 4 5 6 7 8 8.25
Reactor Containment East Floor South 1 meter grid Z=o 8
4 11501-1400 I 1200 1350 7
Rti 1200 -1350 I 1200 1350 76 l l l I 4 j
< _4 -
1100 -1300 - I I I4 -
1200 1550 l l l l 5
N I
E- ,4 - 1150 -1350 If I U 1100 1400
-l I 4 I 1100. -1250
-4 1100 1250 4
7
.1200- -1350 3
1300- 1500 Beta Scan 4
I I - . -
Readings in CPM 2
_1300- -1550 Survey # UVA-FS-019 4- 10 1300 1550 Meter # L2221 172051 Probe # 43-37 161367 1400 -151 0 1 1 Date 6-03-03 1350 -15:
0 4 5 6 7 8 8.25 SW 0 1 2 3
( ( (
( Reactor Containment East Floor North 1 meter grid
(
Z=o
- 16. 5 1250- 1350 ,
16 1250 1350 1250. 1450 4 4 + I ! 15 1150 1300 N
1150 1350 4 4 4. 4 4 N. 14 1150 1250 1150 1300 4 .5. 4- 4 4 4 X 13 N
I 1150 .1250 1200 .1350 12 1200 1350 1300 1450 4 4 4 II 1150- -1300 1200. 1350 10 Beta Scan Readings in CPM - ~1150 -1350 1200 1350 Survey # UVA-FS-019 l9 Meter # L2221 172051 1200 -1350 Probe# 43-37 161367 Date 6-03-03 1150 1300 I 8 0 1 2 3 4 5 6 7 8 8. 25
( ( (
UVAP Radiological Survey Form Location, lRWPIWP I~VFrSvryeP 1t Nuclear Reactor Inside I _I UVA-FS-020 Final Status Survey _
Comments: I S d y Date: [Instrument] Serial# Cal. Due [Probe Ares d Seral Cal. Due l Elf. _ M ax 3 Bkg Lc A!!t-NuclarR.eactor.eBobby Fn SndomG025 Alice Thompson Leigh 04129r03 04ero Tennelec; M-2221 640-52 J 172051 1 4116=2 ir212004 nra 14368126nb 1167181 rife 4/2004 Wel 1107r 331 44
_Jisonbtrand pason Snit2 04r2813 M.2221 184010 32412004 10 nWe 150873 n/a Iv2412t rF. cI.. s- -Ahinu rind R-- 8vt nat.
--Frank Myers o.....t. iosro c3 KqeTI 0 SSmear xoxb -Direct Fns mRad/h -X-X-*i Boundy SO #* General dose rat Smears - - SI ordinal Is
___ CPM
_ DPMii OOmc' _ IUnshIShletcledI aPMOOcm' _
No rt No. CP Netl Lc Nod North I East I Elevation seeI I1 '
435 1 340 705 11 319 10 O 1 rJ5 1 33 429 i 292 1.016 295 0 4 3.3 31Report ! 209 1 21rJ 167 0 2.5 025
-4I-370 311 438 253 11 51 12 12 ._ -_ O!.
4 1.25 125 358 215 1.061 372 279 690 289 1 61 12 4 125 442 316 935 307 11 71 12 2.5 425 816 3D4 iI 81 0.5 4 46 1,009 12 5.1 4
!_ 312 0 5.1 3.3 390 254 1.009 43 5.1 354 1 231 912 263 3.5 5.4 233 .245 264 1 31 3.5 4.5 2 394 1 266 949 22 1 4. 4 511 __5.__2.75 E2tS 27 I5 43 0.5 1 1.7 1,142 252 16 43 4 1 192 211 .141 251 1 3.5 4.5 1 1.25 319 221 727 257 11 181 2.5 4 225 I 191 1 I 1 368 1 238 1 964 267 II 191 3.5 2.5 0 l262 _ 490 3.5 2.5 3.8 l 5M 2.5 3.8 339 385 366 141 331 1.25 125 1478 291 I 8804 11 295 3.1 2.4 Bilas See 8ataed Gamma Spec report 637 275 2.685 11 287 3.5 5.3 Bias
=
~I at1
-t--r--1r-T - - -
FormSEC.RP-21.2 Rev.0
Reactor Containment West Floor North 1 meter grid Z=o 13.9 14300-13 / 15000 14700- . -
15800 12 4 + 4 4-14500-15100 11
.. / 4 4 + 4 4-.
N ,-+ 14200- . 4 .
14900 10 I 9
/1
- - 4 14200-14800 14000-14700
__________ .4.
l
.4.
4 -
4 R /.1I 4 4 4 1 L 14000-14900 7 /1-4 4 4 4 .4 4 It 14700-Survey # UVA-FS-020 Meter# L2221 184010 v P,/- 15400 Probe # 44-10 150873 -2.35 -2 -1 0 1 2 3 4 5 5.8 Date 6-02-03
(
( (
Reactor Containment West Floor North 1 meter grid Z=o 13.9 13 1 12 1 , x, _- (16) 11 /
1 (I11 4. 4. +
N 20 10 I , 4. 4- + -- 4 4 (14) (13 (15 I 9 I I 4- I 4. 4.
8 I I 1 -4.
O denotes smear and static count locations / (1
( 2)
Readings in CPM 7 /, t t I- I 4-Survey # UVA-FS-020 Meter # L2221 103942 6£ 5 5.8 Probe # 43-68 160790 -2.35 -2 -1 0 1 2 3 4 Date 6-03-03
Reactor Containment West Floor South 1 meter grid 6 z=o 5
4 3
N o denotes smear and static count locations Readings in CPM Survey # UVA-FS-020 Meter #L2221 103942 Probe # 43-68 160790 Date 6-03-03 -2.6
-2.50 1 0. 1 2 3 4 5 5.8
(
( (I Reactor Containment West Floor North 1 meter grid
(
Z=o 13.9
/ 1450 --1550 131450 1550
/ 1450 -1650
/ ~1450 1700 12 1400 -1600 1400 1600 11 4- + 1 +
N 1400 -1700 10 1350 1600 4- 4. 4. + 4- 4.-
I 9 1400 -1550 1450 .1600 1350 -1500 1400 1600 8
/ 1450 -1650 1450 1700 7-1400- -1550 Survey # UVA-FS-020 1450- 1600 6_
Meter # L2221 172051 Probe # 43-37 161367 -2.35 -2 -1 0 1 2 3 4 5 5.8 Date 6-03-03
Reactor Containment West Floor South 1 meter grid 6 Z=o 1450 1650 1450 1600 5
1450 1600 1450 1650 4
1450 -1650 1400 1600 3 -
N 1400 -1650 t 1
-4
+
- 4*
1450 1600
+
1550 -1650 1400 1600
+
4-4 I
4 1450 -1600 1400 + 1600 4 1 0
SW 1350 -1650 Beta Scan 1250 .1450 Readings in CPM .4. 4 4 4 4
-1 1250 -1400 Survey # UVA-FS-020 1300 1450 Meter # L2221 172051 -2 Probe # 43-37 161367 1400 Date 6-03-03 . -2.6
-2.50 -2 -1 1 2 3 4 5 5.8
(
C (
Reactor Containment West Floor South 1 meter grid 6 Z=o 4- = = = 14500-15300 5
4 ~~~14500-___
115200 4
,I _ -
14300- I- -*
14900 3
14300-N l w +4 14900
- 4. 4- .
4 4- 4- 4 2- 4.
I 1 7'
4 4
.1 14400-15100 14500- _-I 15000 4 4 SW 0 14000- _ib Gamma Scan 14800 Readings in CPM N 4 t
-1
- _14400-14800 Survey # UVA-FS-020
. . A AA I Meter # L2221 184010 -2 `z- 14300 Probe # 44-10 150873 _470 Date 6-02-03 -2.6 .
-2.50 -2 -1 0 1 2 3 4 5 5.8
( ( (
UVAP Radiological Survey Form Location: lRWPIWP lSU=E# 15Ure Te: IPage I 0115 Demineralizer Room I UVA-FS-021 l Final Status Survey o CommentsB I nstrument Seriit Cal. Du5 Prob Aes Seri t Cal. Due _ _____ M a p Bkg Lc Status Sulvy.Roo M021and Mo21A Alice Thompson 06i50 Tenneec 64052 4116/2004 nVa nh nh - nWe
--- ------ .... _,,Jason Strand 06J430l M-2221 103942 31272004 43-68 126 160750 3/27/2004 0.109 320 Brad Myers BiLeitlO 06 M-2221 184010 31242004 44.10 r 150873 312413004 = nh Dae b 1 M.2221 1 172051 4r21r2D4 143.371 4301 161367 1 4rZr)24 I I .uAW
. ...V*Sien~m
. ri ..... F...
.. . . * ..... IFrank Myers ...
tKeyr I 0t Smreariozlam-DirectFisk Zsw $sYamle *Boun dary SOP
- Step Oft Pad xy
- contatlr 2dose rate 0- General dose ra' Smears Static Count p Coordinates
_ Gros DCPMDPWIOOcrahnsPtded I DPWt0cm' l T1 No Q 1 I a t I CM INet II Le Elevation t1 see I 4
Report 371 328 1 313 374 T 294 I 582 291 3.5 373 290 1 604 289 11 51 1.5 282 1 604 285 1 61 r3.8 5.5 389 1 285 7 375 292 604 I 351 j 2e0 1 517 284 11 42 369 1293 553 290 1 8.4
~772~320 1i 131 7.5 1 5.5 1
I1 442 322 1 874 410 310 1 728 11 299 I
-4.-l -l- t- l - i I l - -I : I-: IC
________________IL' To Form SEC-RP-21.2 Rev.o
Room M021 and M021A Floor 1 meter grid N z=o 3
2 1
0 9
8 Survey # UVA-FS-021 Beta Scan Meter # L2221 172051 Readings in CPM Probe # 43-37 161367 0 denotes smear and static count locations Date 6-04-03 c C (
( (
Room M021 and M021A Room East Wall 1 meter grid E=8.4 3 Z-.I.
AL I
k I
4 2
10800- 11700- 11300- 12000-11;0 13( 0 130 0 12900 1
0 Xr I 1 3 2 1 0 Survey # UVA-FS-021 Gamma Scan Meter# 184010 Readings in CPM Probe 3 150873 Date 6-03-03
Demin Room Inner Walls 10700- 10600- 109 0-10,500- 10600- 10700-11 00 11 00 11 00 I~ 1O100 11200 IF IF ___, _
XI 2 0 I 2 2.3 I 4.4 4 3.7 0 East South West Survey # UVA-FS-021 Gamma Scan Meter# L2221 184010 Readings in CPM Probe # 44-10 150873 Date 6-03-03 Q ( (
(
Room M021 and M021A North Wall 1 meter grid N=3 3
illAil jI Ijt_ 1 .11ASi 2
(§114 00- 11300- 10700- 10800- 10700- 10800- 10800- 102 00- 10600-118,0 11700 113.00* 11400 113.00 115,00 115.00 11C 00 11QOO
___.Ai___ LIII I 1
0 __ ___ ___
0.5 1 2 3 4 5 6 7 8 8.4 Survey # UVA-FS-021 Gamma Scan Meter # L2221 184010 Readings in CPM Probe # 44-10 150873 E
Date 6-03-03
Room M021 and M021A South Wall 1 meter grid N=O 3 L L I A AL AL A I j 2
1I 11800-III 11500- 10500- 1050- 010500-
-II 10400- 10500-
-I10400- 10700-12 00 12 00 11 00 11 00 1 200 11 00 11 00 10700 11 00 1
8.4 8 7 6 5 4 3 2 1 0 Survey # UVA-FS-02 1 Gamma Scan E
Meter#L2221 184010 Readings in CPM Probe # 44-10 150873 Date 6-03-03
( ( (
( (
Room M021 and M021A West Wall 1 meter grid E=O 3
2 N
10700- 10600- 10500-11200 11100 1 100 1
1 I 0
0 1 2 3 Survey # UVA-FS-021 Gamma Scan Meter # L2221 184010 Readings in CPM Probe # 44-10 150873 Date 6-03-03
Room M021 and M02 1A Ceiling 1 meter grid N Z=3 t
10600-
__ f _ 10500- 10700-i 10700-I_
105 00-I 11000-I_
11300-
_I.-
11500-I I 111100 0 I 00 1100 11100 11700 11900 12 00 1
_ 1 _
10600-11100 0 r IF 1 2 3 4 5 6 9 0
-0.3 Survey # UVA-FS-021 Gamma Scan 8 Meter# L2221 184010 Readings in CPM Probe # 44-10 150873 Date 6-03-03
( c (
( .5
(
Room M021 and M021A Floor 1 meter grid N .z=o t
3 2
10500- 10600- 10800- 10600- 10800- 10800- 11000- o80oo-1 11000 11100 100 I 11200 11500 11200 1
10500-10900 r r r Ir 0 p.
I 2 3 4 5 6 1 9 0 -0.3 8
Survey # UVA-FS-021 Gamma Scan Meter # L2221 184010 Readings in CPM Probe # 44-10 150873 Date 6-03-03
Room M021 and M02 1A Room East Wall 1 meter grid E=8.4 3
430-570 540-640 500-650 330-460 2
320-410 350-420 360-520 330-460 1
340-470 350-420 350-410 300-400 0
3 2 1 0 -0.3 Survey # UVA-FS-021 Beta Scan Meter # L2221 103942 Readings in CPM Probe # 43-68 160790 Date 6-04-03
( C.
( (
Demin Room Inner Walls 360-42 310-420 310-400 360-330-420 320-390 390 360-420 300-400 300-40) 33-30 330-390 320-330-3830 400 1D 370-430 320-420 320-43, 320-390 350-420 340-2 0 I 2 2.3 1 4.5 4 3.8 0 East South West Survey # UVA-FS-021 Beta Scan Meter # L2221 103942 Readings in CPM Probe # 43-68 160790 O denotes smear and static Date 6-04-03 count locations
Room M021 and M021A North Wall 1 meter grid N=3 3
330-420 310-420 320-410 330-400 290-390 330-400 310-390 310-390 340-380 2 . 12) 350-450 340-400 275-380 340-400 330-430 320-390 300-380 330-410 350-410 1
350-430 340-400 310-390 320-460 300-380 320-420 350-410 300-390 320-370 0.5 1 2 3 4 5 6 7 8 8.4 Survey AUVA-FS-021 Beta Scan Meter # L2221 103942 Readings in CPM Probe # 43-68 160790 O denotes smear and static count E Date 6-04-03 locations
( ( (
( ( (
Room M021 and M021A South Wall 1 meter grid N=O 3 (Q) -0 -Q 390-430 350-430 320-390 320-4 10 300-390 350-430 340-410 340-410 280-350 2
320.400 320-390 350-450 330-420 290-370 320-380 310-380 330-420 360-430 1
330-400 330-390 330-400 350-430 300-390 320-420 320-410 380-410 350-410
-. ____________________ U J.
J. U .1. __________________
8.4 8 7 6 5 4 3 2 1 0 Survey # UVA-FS-021 Beta Scan E Readings in CPM Meter # L2221 103942 O denotes smear and static Probe # 43-68 160790 count locations Date 6-04-03
Room M021 and M021A West Wall 1 meter grid E=O 3
320-410 320-400 350-440 2
N 300-400 300-390 300-390 1
340-420 350-430 350-460 0
0 1 2 3 Survey #UVA-FS-021 Beta Scan Meter # L2221 103942 Readings in CPM Probe # 43-68 160790 Date 6-04-03
( c (
( ( (
Room M021 and M021A Ceiling 1 meter grid N Z=3.1 0
Beta Scan Survey X UVA-FS-021 Meter # L2221 103942 Readings in CPM %.- B Probe # 43-68 160790 o denotes smear and static Date 6-04-03 count locations
( ( (.
tJVAP L Radiological Survey Form t Location: lRWPIWP lSUrVey 9 lSurM TyM lP!9 F'9 Mezzanine Lab I I UVA-FS-022 Final Status Survey Et5t M ox 6BkqEe Comments: SvTh : o ate: Instrument Sertal Cal. Due Probe .&ea[ SertltJ Cal. Due t s MOS anL MOOSA i Tenne.e 64052 4/16t2004 nha nW nhI_ I fl 9 C..sittorzandower Wals B obby e6igh 06osto M-2221 187752 V11612004 43-61 126 160700 1/16Q004 Qt; -5Se7 v Un 6 .__ __________._........
_ M-2221 1t4010 324/2004 44.10 Ona 1SOS73 3/24Q004 = n ta I Retwed 6y Date:
.__-= _ _ _----.. .-- _ _ _---..
.. _____---- I-5-4-4 I- r 0611201 Kew.I 0
- Smear m t5m*DirectFnsk L _X-X-* Boundarmy SOP
- Step On PadJ y
- contcir dose rate #* Generel zose ral II unto Smears
~
Gross CPM I DPMflOOcm' Unsh/Shlelded DPWNt1tcm`
No a I a I a I P No. CPM Not [0 Elevation sea 15 494 2.5 1.5 361 1 324 1 452 512 0 1 0.9 334 327 - 85 il 514 1.5 I 0 5 . 441 337 1.270 522 5 0 2.75 0.7 6 6 495 320 2173 509 6 0 2.8 1.25 7 7 375 369 73 546 7 0 3.5 0.9 8 a 482 309 Z112 500 8 0 52 1.5 9 9 340 321 232 510 9 1.9 3.5 1.75 10 10 337 335 24 521 10 2 0 1.5 11 __ 11 308 353 .549 535 11 2 0.5 0.9 12 I ___ 12 340 307 403 498 12 2 2.5 °0 aC I QC 302 299 37 492 QC 2 2.5 0 13 13 246 249 .37 449 13 4 0.8 0.5 14 14 336 303 403 495 14 4 1.5 0.9 15 15 343 323 244 511 15 4 3.5 0.9 16 i i -16 451 322 1.575 511 16 4 5.2 1.5 17 ____ 17 379 361 220 541 17 43 0.5 1.75
_18 1 Is 543 363 2.198 542 18 4.3 2.5 1.75 19 19 287 323 .440 511 19 1.8 5 0.2 20 20 357 367 .122 545 20 2 5 0 21 21 458 329 1,575 516 21 2 5.2 1.5 22 i i -22 488 397 1,111 567 22 4.3 5 1.75 QC I I QC 433 368 794 548 CC 4.3 5 1.75 12 __ 12 394 323 867 511 12 2 2.5 0 Drain Cover Removed
%ioor
_ I-1-E l-Form SECARP-21.2 Rev.0
Room M005 and MOO5A Floor 1 meter grid Z =O 4.3m 3 251 269-339 280-315 315-369 361-402 348-423 365 4m 0 09 281-353 287-371 279-364 297-368 350-438 350 3m N
A' 390 318-353 293-364 289-391 294-347 335-429 430
.I 2m Gr -4 .4l .
I s,..7 UE; nSL A->r-4 0+ ohe5AkfVV 4 1" Drain II 333-283-363 291-427 323-378 I ,-284-399 321-379 374 Im -4 +
294-435 320-404 319-286-343 354 288-403 307-387 n4. (7) 0 1 2 3 4 5 5.2 Survey# UVA-FS-022 Beta Scan Meter # L2221 187752 Readings in CPM Probe# 43-68 160700 O denotes smear and Date 6-05-03 static count locations
( ( (
( (
Room M005 North Wall 1 meter grid N=4.3 3
2
-- u - U416 332-456 322-425 306-529 317-426 353-449 450 296-341 281-363 290-368 290-341 243-382 332 371 0
1 2 3 4 5 5.2 Survey# UVA-FS-022 Beta Scan Meter # L2221 187752 Readings in CPM Probe# 43-68 160700 o denotes smear and Date 6-05-03 static count locations
Room M005 and M005A South Wall 1 meter grid N=O V V I I 3
2 315-489 355-472 360] 439-503 376-480 7 ) 259-314 ()
4401 __
1 280- 365 257-403 275-335 268-319 328 414 0
5.2 5 4 3 2 1 Survey # UVA-FS-022 Beta Scan Meter # L2221 187752 Readings in CPM Probe# 43-68 160700 O denotes smear and Date 6-09-03 static locations
( ( (
( (
Room M005 West Wall 1 meter grid E =O 3
2 N
306-491 267-340 277-430 289-451 321-410 I10 1
294-334 259-379 244-339 248-323 13 262-323 0 1 2 3 4 4.3 Survey # UVA-FS-022 Beta Scan Meter # L2221 187752 Readings in CPM Probe# 43-68 160700 o denotes smear and Date 6-05-03 static count locations
Room M005 Inner East Wall 1 meter grid E=2.8 3
2 N
275-456 423-478 1*
292-346 35 1-482 2 1 0 Survey # UVA-FS-022 Beta Scan Meter # L2221 187752 Readings in CPM Probe# 43-68 160700 Date 6-09-03
( ( (
( ( (
Room MOO5A West Wall 1 meter grid E=2.8 3
2 371-496 329-399 1
385- 265-480 496 0 1 2 Survey# UVA-FS-022 Beta Scan Meter# L2221 187752 Readings in CPM Probe# 43-68 160700Date 6-09-03
Room M005 Inner South Wall 1 meter grid N=2 3
2 340- ~i 408 405-468 274-324 343-389 1
379-476 442-5 14 234-385 329-430 0
5.2 5 4 3 2.8 Survey # UVA-FS-022 Beta Scan Meter # L2221 187752 Readings in CPM Probe# 43-68 160700 o denotes smear and Date 6-09-03 static count location (C' ( c
( (
Room M005A North Wall 1 meter grid N=2 3
2 340-398-468 405-523 4153 403 1
393-496 372-503 355-472 332.
76 2.8 3 4 5 5.2 Survey # UVA-FS-022 Beta Scan Meter # L2221 187752 Readings in CPM Probe#I 43-68 160700 odenotes smear and Date 6-09-03 static count location
Room M005 and MOO5A East Wall 1 meter grid E =4.2 3
2 16 21 422 395-464 426-500 291-549 371-480 524 _ _ _ _ _ _ _ _ _ _
1 N*~ 384-542 379-468 270-348 235-321 4.3 4 3 2 1 0 Survey# UVA-FS-022 Beta Scan Meter # L2221 187752 Readings in CPM Probe# 43-68 160700 O denotes smear and Date 6-05-03 static count locations
( ( (
( (
Room M005 and MOO5A Floor 1 meter grid Z=O 4.3m North SW 0 1 2 3 4 5 5.2 Survey # UVA-FS-022 Gamma scan Meter # L2221 184010 Readings in CPM Probe I 44-10 150873 Date 6-04-03
Room M005 North Wall 1 meter grid N =4.3 3
I 2 10500- 9000- 9400- 8100- 9100- 10300
- E 1 1 000 T
1 13200 TIAT 1 000 FIf To 10500 12z 00 11301 0
1 2 3 4 5 5.2 Survey # UVA-FS-022 Ganuna scan Meter# L2221 184010 Readings in CPM Probe# 44-10 150873 Date 6-04-03
( ( (
( (
Room M005 and MOO5A South Wall 1 meter grid N=O 3
2 11 9600- 9800- 10400- 10400- 10300-1170( 11500 11400 11500 11100 11100 1
5.2 i 5 4 3 i 2 1
_1111 0
Survey # UVA-FS-022 Gamma Scan Meter# L2221 184010 Readings in CPM Probe# 44-10 150873 Date 6-04-03
Room M005 West Wall 1 meter grid E =4.2 3
2 9600- 9300- 9500- 9300- 11100-1 800 10300, 12600 1 000 12200 1
. IF , lr.
0 1 2 3 4 4.3 Survey # UVA-FS-022 Meter# L2221 184010 Probe# 44-10 150873 Date 6-04-03 c (
( (
Room M005 Inner East Wall 1 meter grid E=2.8 3
2 10300- 10200-11 00 11 00 1
2 1 0 Survey # UVA-FS-022 Gamma Scan Meter # L2221 184010 Readings in CPM Probe# 44-10 150873 Date 6-04-03
Room MOO5A West Wall 1 meter grid E =2.8 3
2 10000- 10300-1 900 10800 1
0 1 2 Survey # UVA-FS-022 Gamma Scan Meter # L2221 184010 Readings in CPM Probe# 44-10 150873 Date 6-04-03
( c c
( (
Room M005 Inner South Wall 1 meter grid N=2 3
2 1120 - 11000- 9500- 9500-E 1170 1 500 10 00 10900 1
', ,-ii 0 5.2 5 4 3 2.8 Survey# UVA-FS-022 Gamma Scan Meter# L2221 184010 Readings in CPM Probe # 44-10 150873 Date 6-04-03
Room M005A North Wall 1 meter grid N=2 3
2 9900- 10300- 10400- 1000(
I.
10100 1100 1100 1060(
4 1
- = _ I 3 4 5 5.2 Survey # UVA-FS-022 Gamma Scan Meter # L2221 184010 Readings in Probe# 44-10 150873 CPM Date 6-040-3
( (
( (
Room M005 and MOO5A East Wall 1 meter grid E =4.2 3
2 tI I I 1 1060( 10100- 11000- 10300- 11100-12f O1 1j300 1 700 10900 12000 II 1
XT.
1N -'
4.3 4 3 2 1 0 Survey # UVA-FS-022 Gamma Scan Meter# L2221 184010 Readings in CPM Probe# 44-10 150873 Date 6-04-03
( ( (
UVAP Radiological Survey Form Location:lW IPlSret lS-r~yyTyp ;1tt Heat Exchanger Area U-VA-FS-023 Final Status Surses geo Comments: surveyedy D Instrument Serial ] Cal. Due I ProbeArea Serial N Cal. Due __IA3 Ef.1 M ax 13Blk Lc FnAalStics Suv d RoXrn0024 Alice Thom pson 06M Tennelec 64052 4ii6t2004 nh nta W/a nhs n _
Ctassl Fbo.LovWalsandC.8wf Jason Strand 0653I M-2221 103942 3/27t2004 43e8 126 160790 3t27t2004 _ 0.109 341 SuBradit19 r Myers 0605031 M.2221 184010 3t24t2004 44.10 nW 150873 3/24/2004 = nh FI- Status Survey Addenrdn 004 I ROVh.Ad R, Dat II M-2221 1 172051 4tt20D4 143.371*13I 16137 I 412t2004 nta
.r:_. .FrnkM ers . .....
06t1103 _ _ I I_ I_ I- _
(Xww - Direct Frisk a-r ample B-bet dose rate inmRadi .X..X--6 Boudary SOP-Sbtep Off Pam xty-ontacdt122dose rate N.- Generaldoserar Smears Static Countl Coordinates 0 Gross CPM OPMtlOerm' t UnshfShlelded DPM3 OOcem East Elevation No. a a No. CPM Net Le No North 1 See 1 384 351 240 318 1 3 7.5 3 2 At e 2 373 305 495 296 2 3 4.5 3 3 Report 3 383 321 451 304 3 3 1.5 3 4 4 397 322 546 304 4 1 3 3
_ 5 428 317 808 302 5 0 0O 3 6 5802 337 1.201 311 6 1 6 3 7 7 428 319 794 303 7 3 6 1 8 383 274 794 281 8 3 3 1 9 9 332 307 182 297 9 2 0.5 1.5 10 _1 3S0 308 524 298 10 2 1.5 0 11 11 439 297 1.034 292 11 0 0 0 12 12 438 270 1.223 279 1210 1.5 2 13 13 439 328 808 307 13 0 3 0 14 14 557 385 1 252 333 14 0 6 0 1' 1' 489 405 612 341 15 0 0.6
-16 1 381 345 262 315 16 2 84 2 17 17 436 352 612 318 17 2 7.5 0 496 L 3371 1.158 311 4.5 ias pointin sump
_ I_ - 1-__ I_
i=I I _I _
= Il I I I _ -
Form SEC-RP-21.2 Rev.0
Room G024 Floor 1 meter grid Z=o IltI 2LLI ItILI 3
N 2
t I
- ~ 1716 j0 110 10 110150 100 1200-1250- 1150- 1300-1150- 1350- 1350- 1300- 1150- 135 Sump I
0 .
r
. . . l. . .
F, I. . .
0 1 2 4 5 6 7 8 3
Survey # UVA-FS-023 Beta Scan Meter # L2221 172051 Readings in CPM Probe # 43-37 161367 Date 06-05-03
( ( (
I
C (- (
Room G024 East Wall East =8.4 3
2 1
0 0
3 2 1 Survey # UVA-FS-023 Beta Scan Meter # L2221 103942 Readings in CPM Probe# 43-68 160790 o denotes smear and Date 06-05-03 static count locations
Room G024 North Wall North = 3 3
400- 350- 330- 330- 360- 400- 360- 380- 430-440 420 430 390 450 490 420 460 490 2
360- 330- 380- 320- 300- 380- 450- 5200 510 400 420 460 390 400 46045 0 51 1
350- 340- 320- 340- 360- 400- 340- 460- 450-380 410 490 440 450 490 480 520 500 0
0.5 1 2 3 4 5 6 7 8 8.4 Survey # UVA-FS=023 Beta Scan Meter # L2221 103942 Readings in CPM Probe# 43-68 160790 o denotes smear and static Date 06-05-03 count locations E
( (
( (
Room G024 South Wall North = 0 3
370- 360- 370-390 400 400 340- 350- 330- 350- 340-2 430 430 400 420 410
.12 380- 330- 310- 320- 340-Opening 430 410 420 440 410 1
Beta Scan 330-Readings in CPM 370- 430 320- 350- 340-O denotes smear and 440 440 410 430 static count location -1.3 0
7.4 7 6 5 4 3 2 I 0 Survey # UVA-FS-023 Meter # L2221 103942 Probe # 43-68 160790 E -A Date 06-05-03
Room G024 West Wall East =0 3
380- 320- 330-460 460 440 2
290- 300- G 280- N 350 400 360 1
300- 390- 320-400 500 410 0 1 2 3 Survey # UVA-FS-023 Beta Scan Meter # L2221 103942 Readings in CPM Probe 4 43-68 160790 O denotes smear and static Date 06-05-03 count location
( ( (
( (
Room G024 Ceiling 1 meter grid Z=3 370-400 390-470 J 340-430 380-460 370-450 330-430 j 400-490 420-480 340-400 I
I4----
380-450 380-380-470 400-330-400 380-4 420-460 400-390-460 370-400-480 390-I D0I 450-530 430-
+
440-500 400-390-470 4-450-470 490 450 490 490 480 500 500 520 S
0 1 2 3 4 5 6 7 8 8.4 Survey # UVA-FS-023 Beta Scan Meter # L2221 103942 Readings in CPM Probe# 43-68 160790 o denotes smear and Date 06-05-03 static count locations
Room G024 Floor 1 meter grid z=o 3
N 280-320 280-3 320-390 330-440 2 17 350- 280- 350- 340-400 360 470 450 I
I Sumn 330- 340- 320-410 420 420 0 X 0 1 2 4 5 6 7 8 8.4 3
Survey # UVA-FS-023 Beta Scan Meter # L2221 103942 Readings in CPM Probe # 43-68 160790 O denotes smear and Date 06-05-03 static count locations
( ( (
( (
Room G024 East Wall E =8.4 3
z 2 I I 11 11800- 11900- 12000-12500 12 00 1T00 1
0 3 2 1 0 Survey # UVA-FS-023 Gamma Scan Meter # L2221 184010 Readings in CPM Probe# 44-10 150873 N Date 06-05-03
Room G024 North Wall North = 3 3
2 10400- 10800- 10700- 10500- o11000- 1140i- 11700- 11600-10 114 00 11500 11500 11900 12 00 1200 12500 123200 I__
1 0 _ _ V_ _ _ _
0.5 1 2 3 4 5 6 7 8 8.4 Survey # UVA-FS-023 Gamma Scan Meter # L2221 184010 Readings in CPM Probe # 44-10 150873 Date 06-05-03
( ( (
(C (7 Room G024 South Wall N=O 3 71 l l 12300-12300- l Alisjs I 1 13400 2 I-11600- I 00- Joc00-1 11l00- 4 (500-Opening 12400 12500 12100 12 00 11 !_00 41 1
I.~~
0 8.4 8 7 6 5 4 3 2 1 0 Survey # UVA-FS-023 Gamma scan E Meter 3 L2221 184010 Readings in CPM Probe # 44-10 150873 Date 06-05-03
Room G024 West Wall E=O till 12200-12900 11500-12 00 10600-1 E00 N
I 1E 1 2 3 Survey # UVA-FS- 023 Gamma Scan Meter # L2221 184010 Readings in CPM Probe# 44-10 150873 Date 06-05-03
( ( (
( (
Room G024 Ceiling 1 meter grid Z=3 I-Z - I I i I 1 10900- 11000- 10800- 10900- 10800- 11000- 11500- 12000- 1300 118100 -4 115~00 1 113~00 40 1150 I~ 1113120
-10 130 12100 30 Z r F r r F, p.
0 1 2 3 4 5 6 7 8 8.4 Survey # UVA-FS-023 Gamma Scan Meter # L2221 184010 Readings in CPM Probe# 44-10 150873 Date 06-05-03
Room G024 Floor 1 meter grid z=o 3
N 2
I 1 i
11300-12O00 _
10800-11_00 10900-
- 11700 11900-12400 11900-13300 12100-14jO0 13000-15500 130( 0-1.51( 0 Sump 2000-0 1:3100 r F r Ir 0 1 2 4 5 6 7 8 8.4 3
Survey # UVA-FS-023 Gamma Scan Meter # L2221 184010 Readings in CPM Probe # 44-10 150873 Date 06-05-03
( c (
( (
Room G024 Hx Sump 1 meter grid
- 12800-13400 N
350-I *12600-13400 430
- 13500-14600
- 12600-13500 430- 330- 450-560 550 600
- 12800- -1.3 13600 420-520 Survey # UVA-FS-023 2.9 3.8 Meter# L2221 103942 Beta Scan Probe# 43-68 160790 Meter # L2221 *184010 Gamma Scan Probe d 44-10 *150873 Readings in CPM Date 06-05-03
(. (6VAP C Radiological Survey Form Location: Nula ectrIsd RWP/WP - Survey # JSurvey Type SttsSre Page I of 12 Comments: Surveyed By: Date: Instrument Serial U Cal. Due Probe Area Serial U Cal. Due ____ 1 Eff. MaIx 1 Bkg Lc inlSts reyfooM09Alice Thompson 06/12103 Tennetec 84052 0411812004 n/a n/a n/a n/a n/a n/a n/a n/a FalSauSrvynt08Jason Strand 06/09/03 M-2221 103942 0312712004 43.68 126 160790 03/27/2004 n/a -0.109- n/a 349 QaqtftqjyA. e*Adnum04Brad Myers 06/07/03 M-222i 172051 04/02/200 43.37 430 16136 04102J2004 n/ta 0.109 n/a n/a
... Reviewed By: Date: M-2221 184010 03/24/2004 44-410 n/a 150873 03/24/2004 n/a n/~a n/a n/a
___ __ __ ___ ___ __ ___ __ Frank M yers 06/13/03 _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _
Key:I () = Smearxxxctox~c=D~jectFrjsk ni~airsample B =beta dose rate in mRadlhr -X-X.- = Boundary SOP Steo-Off Pad xy contact/12'dose rate #1 Generil dose rate Smears Static Count 13 Coordinates a 2
Gross CPM DPM1lO0cm Sample/Bkq DPM/l00cn9 -___
No. o a N. CPM Net Lc No. North East Elevation
__I See 1 568 1358 1.529 321 1 2 9 2
__2 Attached 2 343 305 277 296 2 4.5 9 0.5
__3Report ____3 591 399 1.398 339 3 0 0.5 0.5 4 4 561 379 1.325 330 4 0 3.5 0.5
__5 _ _ 5 513 355 1,150 320 5 0 6.5 0.5 8 ____ 6 392 343 357 314 6 2 0 1 7 _____ 7 421 403 131 341 7 6 2 1 6 _ 6_ 351 311 291 299 8 5 5 1 9 9 312 322 -73 304 9 5 8 1 10 ____ 10 586 403 1,332 341 10 2 2 0 12 11 494 406 641 342 11 2 5 0 12 ___ 12 471 380 663 331 12 2 8 0 13 13, 462 373 648 328 13 4.5 0.9 0 14 ____ 14 459 370 648 326 14 4.5 3.5 0 15 15 530 423 779 349 15 4.5 6.5 0 QC - _ _ QC 507 367 1.019 325 QC 4.5 6.5 0 16 - ___ 16 361 345 116 315 16 0.5 6.5 0.6 iri sink 17 ____ 17 371 357 102 321 17 5.4 3.7 0.95 Lab Hood 18 __ 18 459 280 1.303 284 18 6 2.6 0.95 Lab Hood 19 __ 19 323 24 37 281 '19 6 3.4 0.95 Labi-Hood
-4 4
- .4.- 4- 4 + II 4 1 I II - I 4 t
_______ I
- . I Form SEC-RP-21.2 Rev.0
Room MO 19 floor 1 meter grid Z=o 5.3 Hc od Hood 5
I 11260-1460 1 N i 1215-142_ Z 4
- 4. 1220-155C _ _ +_ _ _ _ _ _ _
370-in-.- + 4 1320-145C11 4 + 4.-U 430 3
1250-153C
_i :
I-jjj_ _ _ _ _ _
360-1300-1480 410 2
.4 1290-1540 0 Beta Scan Readings in CPM 4 ==1250-1520 1
Survey #UVA-FS-024 Meter # L2221 172051 4 - 1460-1530 1380-1520 Probe # 43-37 161367 Meter # L2221 109742 1350-1550 300-400 300-420 290-400 Probe # 43-68 160790 Date 06-09-03 0 I 1 2 3 4 5 6 7 8 9 c ( (
( ( (
Room MO 19 floor 1 meter grid 6 Z=o 5.3 5
N 4
3 2
Survey # UVA-FS-024 Meter # 12221 103974 Probe #43-68 160790 1 Date 06-09-03 o denotes smear and static count locations 0
0 1 2 3 4 5 6 7 8 9
Room MO 19 North Wall 1 meter grid N=5&6 3
2 33-Hood Hood 300 270- 280- 20 9- 20 380 290- 280- 330- 390 360 400 240 360- 3260 380430 420 410403630 1
370- 290-420 390- 330- 300- 260- 300- 250- 300- 340 470 440 400 350 400 330 360 0
0 I 2 3 4 5 .6 7 8 9 Survey # UVA-FS-024 Beta Scan Meter # L2221 103942 Readings in CPM Probe 4 43-68 160790 o denotes smear and static Date 06-09-03 count locations
( ( (
( C Room MO 19 South Wall 1 meter grid N= 5&6 3
2 380- 340- 360- 350- 410- 410- 320- 380- 480-600 540 560 550 620 610 570 550 570 1
530- 250- ( 330- 490- 4- 450-3 610 560 330- . 580 580 500- 580 560 480-
- 480 Cabinet _580 _5 .
9 8 7 6 5 4 3 2 1 0 E 4
- Survey # UVA-FS-024 Beta scan Meter # L2221 103942 Readings in CPM Probe # 43-68 160790 o denotes smear and static Date 06-09-03 count locations
Room MO 19 West Wall 1 meter grid E =44.3 3
2 0 N 400- 320- 320- 330- 290-1 490 400 404037 350- 360- 360- 300- 340-0 440 420 430 420 0 1 2 3 4 5 Survey # UVA-FS-024 Beta Scam Meter # L2221 103942 Readings in CPM Probe # 43-68 160790 O denotes smear and Date 0-09-03 static count locations
( ( C
( ( (
Room MO19 East Wall 1 meter grid E= 53.3 3
2.
440- 360- 380- 380- 420-510 540 590 540 620 1
O 290-300-380 Cabinet 260-410 400-500 450-560 0
5 4 3 2 1 0 Survey # UVA-FS-024 Beta Scan Meter# L2221 103942 Readings in CPM Probe # 43-68 160790 O denotes smear and static Date 06-09-03 count locations
Room MO 19 floor 1 meter grid 6 Z=o 5.3 Hdod Hood 5
N 4 I!A I I A I A
AL 3 -I-D 1l 000-13800- 13200- 13500- 13400- 13000- 13000- 13000- 12800-
~100 14500 14200 14400 14500 14200 13800 13500 13300 2 l I I I I , I , I I , I ,I l I 1
Survey # UVA-FS-024 Meter # L2221 184010 Probe # 44-10 150873 Date 06-07-03 I +__ +II IE1 I11 Gamma Scan Readings in CPM 1 2 3 4 5 6 7 8 9
( C (
( C Room MO 19 North Wall 1 meter grid N=5&6 3
2 Hod Hoc d_
0 E.
9400- 9500- 9400- 9200- 11900- 11700- 11700- 11700- 12000-10500 10000 9800 9800 12600 12400 12300 12300 12500 0
0 1 2 3 4 5 6 7 8 9 Survey # UVA-FS-024 Gamma Scan Meter L2221 184010 Readings in CPM Probe# 44-10 150873 Date 06-07-03
Room MO 19 South Wall 1 meter grid N= 5&6 3
2 15000- 14900- 14800- 14800- 15000- 15000- 14900- 15000- 15200-15600 5400 15 00 15200 1 600 159 00 15' 00 15' 00 15 00 1
Cabinet -
0 9 8 7 6 5 4 3 2 I 0 E -q Survey # UVA-FS-024 Gamma Scan Meter # L2221 184010 Readings in CPM Probe # 44-10 150873 Date 06-07-03
( ( (
( C(
Room MO 19 West Wall 1 meter grid E =44.3 3
2 14300- 14400- 14300- 13800- 12900-14 00 14 00 1' 700 1 400 1 900
- N 1
0 0 1 2 3 4 5 Gamma scan Survey# UVA-FS-024 Readings in CPM Meter 4 L2221 184010 Probe# 44-10 150873 Date 06-07-03
Room MO 19 East Wall 1 meter grid E = 53.3 3
2 13000- 13700- 13700- 13900- 13900-1 100 1 200 1 200 14300 15(00 1
IF 2 *,Cabinet r I, 0 5 4 3 2 1 0 Survey# UVA-FS-024 Gammna scan Meter# L2221 184010 Readings in CPM Probe# 44- 10 150873 Date 06-07-03 C C (7
( C (
UVAP Radiological Survey Form Locatlon: lRWPIWP Sunvey# SurveyType: Page I of 17 Nuclear Reactor Facility Inside I UVA-FS-025 Final Status Surve _
Comments: . d Br onto: Instrument Serial ft Cal. Due Prob Area Serial 1 Cal. Due _ D Eff._ M ax a Bk Lc SISAs omM005)00SA Thonemeson 0611e l Tenelec o6r 64052 411612004 nta I nta a nh = nta _I .I Class- Wa--s-andCen ---. obby Leigh 06MG311 M-2221 187752 1t1612004 43-68 126 1607C0 116/2o004 0.065 548 Survey Urit 37 M-2221 1 184010 3124i2004 144-101 Ina 1 50873 1 31242004 I I n/a RevIewed BR Date! I 06itt03
- bela
- aose rate mmRad/h -X-X-
- Boundaly SOP
- Step Off Psd xt
- cntac12 dose rate C. General dose ra' Coordinates 1
N 2!
GrossCPM n
See
-p I DPMfWlOCn I n I P l
F[No l I UnsaShltlded CPM DPMWIO.Cn'
'iI2 0 1 3 2 361 300 745 493 0.5 1 0.2 2.5 3 602 1 319 I 3.45511 506 1 4I 0.5 2 3 5 5 405 320 1.038 509 5 0.5 2.8 2.25 6 6 556 33 2.686 521 6 0.5 _ 4 3 7 7 461 298 1.990 491 7 1.8 _ 3 2.75 8 8 455 329 1.538 516 8 1.9 4 2.75 9 9 501 365 1.661 544 9 3 1 0 2 10 10 557 371 Z271 548 10 3 1 3 11 11 475 348 1.551 531 11 3 3 3 12 12 502 338 Z002 523 12 3 5 3 13 13 378 311 818 502 13 43 0 2.75 14 14 376 353 281 535 14 4.3 2 2.75 15 i 15 406 314 1.123 504 15 4.3 l 4 .75 18 16 559 357 2.466 538 16 1.8 5 3 17 17 460 330 1.587 517 17 0 5 2 18l 18 419 297 1.490 490 18 0.5 5.2 2.25 QC QC 432 329 1258 516 QC 0.5 52 i 225
- -F Fonm SEC-RP-21.2 Rev.0
Room M005 North Wall 1 meter grid N=4.3 3 r I I 411-497 (0)322-429 (p357-455 2
1 0
1 2 3 4 5 5.2 Survey # UVA-FS-025 Beta Scan Meter # L2221 187752 Readings in CPM Probe# 43-68 160700 O denotes smear and Date 6-10-03 static count locations C c
( (7 Room M005 and MOO5A South Wall 1 meter grid N=O 3
362-441 389-497 379-499 2
17__ _ _ _ 2__ __ _ 1 1
0 5.2 5 4 3 2 1 Beta Scan Survey # UVA-FS-025 Readings in CPM Meter # L2221 187752 Probe # 43-68 160700 o denotes smear and static count locations Date 6-10-03
Room M005 West Wall 1 meter grid E =O 3
0 396-540 323-435 2
N 1
0 1 2 3 4 4.3 Survey # UVA-FS-025 Beta Scan Meter# L2221 187752 Readings in CPM Probe# 43-68 160700 o denotes smear and Date 6-10-03 static count locations
( (
(7 ( (7 Room M005 Inner East Wall 1 meter grid E=2.8 3
2 N 4-I 2 1 0 Survey # UVA-FS-025 Beta Scan Meter # L2221 187752 Readings in CPM Probe# 43-68 160700 o denotes smear and Date 6-10-03 static location
Room M005 Inner South Wall 1 meter grid N=2 3
2 1
0
- 5.2 5 4 3 2.8 Survey # UVA-FS - 025 Beta Scan Meter # L2221 187752 Readings in CPM Probe# 43-68 160700 O denotes smear and static Date 6-10-03 count locations
( ( C
C ( (
Room M005A North Wall 1 meter grid N=2 3
0 414-505 2 4 4 1
2.8 3 4. 5 5.2 Survey # UVA-FS-025 Beta Scan Meter# L 2221 187752 Readings in CPM Probe# 43-68 . 160700 o denotes smear and static Date 6-10-03 count location
Room M005 and M005A Ceiling 1 meter grid Z=3 5
4 451-554 381-484 384-601 N
AI 3 10 RI______1 12e __1 408-552 C16 2
1 411-540 374-572 t
4 6 I 2 3 4 5 5.2 Survey # UVA-FS-025 Beta Scan Meter# L2221 187752 Readings in CPM Probe # 43-68 160700 o denotes smear and Date 6-10-03 static locations c (
(
( (
Room M005 and M005A East Wall 1 meter grid E=5.2 3
389-468 2
I 4.3 4 3 2 1 0 Survey # UVA-FS-025 Beta Scan Meter # L2221 187752 Readings in CPM Probe # 43-68 160700 O denotes smear and Date 6-10-03 static count location
Room M005 North Wall 1 meter grid N=4.3 3
11600- 11300-12200 14900 l 2500 -
2 1
0 1 2 3 4 5 5.2 Survey # UVA-FS- 025 Gamma Scan Meter# L2221 184010 Readings in CPM Probe 3 44-10 150873 Date 6-10-03
(. (.~c (
(- (
Room M005 and M005A South Wall 1 meter grid N=O 3
11300- 9600- 7400-11600 11100 11300 2
1 E 4-0 5.2 5 4 3 2 1 GaInma Scan Survey # UVA-FS-025 Readings in CPM Meter # L2221 184010 Probe # 44-10 150873 Date 6-10-03
Room M005 West Wall I meter grid E=O 3
2 N
I 0 2 3 4 4.3 I
Survey # UVA-FS-025 Gamma Scan Meter# L2221 184010 Readings in CPM Probe# 44-10 150873 Date 6-10-03
(. ( (.
( ( (7-Room M005 Inner East Wall 1 meter grid E=2.8 3
2 I
2 1 0 Survey # UVA-FS-025 Gamma Scan Meter# L2221 184010 Readings in CPM Probe# 44-10 150873 Date 6-10-03
Room M005 Inner South Wall 1 meter grid N=2 3
11200-
__o12100 __
2 I
0 5.2 5 4 3 2.8 Survey # UVA-FS - 025 Gamma Scan Meter # L2221 184010 Readings in CPM Probe# 44-10 150873 Date 6-10-03
( ( (
( ( (
Room MOO5A North Wall 1 meter grid N=2 3
10600-11400 4 4-2 4 1
2.8 3 4 5 5.2 Survey # UVA-FS-025 Gamma Scan Meter# L 2221 184010 Readings in CPM Probe# 44-10 150873 Date 6-10-03
Room M005 and MOO5A Ceiling 1 meter grid Z=3 5
4 N 11700- 11100- 10700-12400 12400 11300 L
3 10700-~_
11100 2
1 10200- 10900-11300 fi 11300 1 2 3 4 5 5.2 Survey # UVA-FS-025 Gamma Scan Meter# L2221 184010 Readings in CPM Probe# 44-10 150873 Date 6-10-03
( ( (
( C Room M005 and M005A East Wall 1 meter grid E = 5.2 3
8400-11100 2
I NT4~~
4.3 4 3 2 1 0 Survey# UVA-FS-025 Gamma Scan Meter # L2221 184010 Readings in CPM Probe # 44-10 150873 Date 6-10-03
( ( (-
UVAP 0 Radiological Survey Form Location: RWP/WP: Suv lSreTy": Pagetl of11t Nuclear Reactor Inside Ie UVA-FS-026 FinStatus Survey Comments: 5 rvdBy. Date: Instment Sela Cal. Due Prob Area Seai Cal. Due _ Effll Max BkgLc FSuvey oomM019 IAlice Thompson wan:O Tennetee 64052 4/182004 Snhl rNS nri nWe n Ctass 2 Uefwsceitg . Jason Strand Wtoaio M 2221 103942 3127r2004 l43-68 l 1260 160790 327Q2004 - Otr 349 S Un-t 39 ---- -------------- M-221 184010 3w24/04 l44tO I ra I 150873 MUM = /a I
..... u ~e9atsSry I Reviewed RBs Date FrankMyers -
O&p i _ _ _ -1 - =. x/yconc12 d
- s-W a ele N -bets dose rate in m____ -X-
- Boun~dary SOP
- Step 0il Pad s/y
- contaWlt dos . General dose ra Static Count B Coordinates a Gross CPM I DPM/tOOcm' I Uns..Shlelded I ODPM1Ocrm' No - E -- N o__ CPM No SeeI 4 I 5 4
--3 I 529 4231 772 349 1.5 425 3 Report 3 535 407 l 932 34t2 31 .5 75 3 4 41 6_38 397 11.755 338 41 3.5 l 0.5 3 5 5 594 402 1t398 340 5 3.5 1 3 3 6 t 538 405 947 342 6 3.5 1 5.5 3 7 7 595 424 1t245 349 7 3.5 8 3 a a 599 385 1.558 333 a 1.5 9 2.75 9 _ 9 663 398 1.930 338 9 0 0.5 2.5 10 = = 10 364 345 138 315 1t 0 3 l 25 11 it 291 272 138 280 11 0 5.5 2.5 12 12 396 339 415 312 12 0 8 25 13 13 385 319 481 303 13 1.5 0 225 14 14 405 386 138 333 14 5 1.75 2.5 11 15 287 303 -116 295 15 5 4.25 2.5 16 _ 16 307 294 95 291 16 5 6.75 2.5 QC QC 322 291 226 289 QC 5 6.75 2.5 17 7 _ 17 390 345 328 315 17 4.9 2 2 Inside lab hood valance
= ..== _-- = -
-
_ _J- _~-I Form SECRAP.21.2 Rev.O
Room MO 19 Ceiling 1 meter grid 6
Z=3 5
N 4 i w w i V jI 12800- 13000- 13000-12900- 13700 13600 13500 3 13700 2
13300- 13700- 13300-14100 14200 13800 1
Survey # UVA-FS-026 I Meter#L2221 184010 Probe # 44-10 150873 Date 6-10-03 Gammna Scan 0 Readings in 0 1 2 3 4 5 6 7 8 9 CPM
( ( (
( (
Room MO 19 North Wall 1 meter grid N=5&6 3
11700- 10700- 10800-2 1o99 H100 1d
_ Hoc d Hood.
- E0 T < <<
0o 0 1 2 3 4 5 6 7 8 9 Survey # UVA-FS-026 Gamma Scan Meter # L2221 184010 Readings in CPM Probe # 44-10 150873 Date 6-10-03
Room MO 19 South Wall 1 meter grid N= 5&6 3
12800- 12500- 12700- 13300-13500 13800 13400 14600 2 1
Cabinet 0 9 8 7 6 5 4 .3 2 1 0 E
Survey# UVA-FS-026 Gamma Scan Meter # L2221 184010 Readings in Probe# 44-10 150873 CPM Date 6-10-03
( ( c
(. C Room MO 19 West Wall 1 meter grid E = 44.3 3
10100-12600 2
0 N 1
0 0 1 2 3 4 5 Survey A UVA-FS-026 Gamma Scan Meter # L2221 184010 Readings in CPM Probe # 44-10 150873 Date 6-10-03
Room MO 19 East Wall 1 meter grid E= 53.3 3
13800S 15000 2
1 CabinetIII 0 5 4 3 2 1 0 Survey # UVA-FS-026 Meter # L2221 184010 Probe# 44-10 150873 Date 6-10-03
(
( (- (
Room MO 19 Ceiling 1 meter grid Z=3 7
5 7 7 7 1 N
4 Ak 450-0 420- 0 415-415-550 0
590 590 560 3
2 0 0 0 430- 460- 440-
_ __XC7 Survey # UVA-FS-)26 1 Meter# L2221 103942 Probe# 43-68 160790 Date 6-10-03 Beta Scan Readings in CPM 0 o denotes smear and 0 1 2 3 4 5 6 7 8 9 static count locations
Room MO 19 North Wall 1 meter grid N=5&6 3
320- 250- 250-420O(3)330 330 16 2
E ood Hood II E 1 _ 4 _ .. f _
. r -
_ i, _} ._ .
0 0 1 2 3 4 5 6 7 8 9 Survey# UVA-FS-026 Beta Scan Meter # L2221 103942 Readings in CPM Probe # 43-68 160790 O denotes smear and static Date 6-10-03 count locations
( (
( C Room MO 19 South Wall 1 meter grid N= 5&6 3
300- 290- 300- 410-410 120400 570
~D10 2
1 1 Cabinet 0 9 8 7 6 5 4 3 2 1 0
.4 E
Survey# UVA-FS-026 Beta Scan Meter # L2221 103942 Readings in CPM Probe # 43-68 160790 O denotes smear and static Date 6-10-03 count locations
Room MO 19 West Wall 1 meter grid E =44.3 3
340-410 2
. N 1 4. 4 4. 4.
0 0 1 2 3 4 5 Survey # UVAOFS-026 Beta Scan Meter # L2221 103942 Readings in CPM Probe# 43-68 160790 O denotes smear and Date 6-10-03 static count locations
( (. (
< c Room MO 19 East Wall 1 meter grid E= 53.3 420- 3 6Q U8 2
I _ _ _ 1 Cabinet 0 5 4 3 2 1 0 Survey# UVA-FS-026 Beta Scan Meter # L2221 103942 o denotes smear and Probe # 43-68 160790 static count location Date 6-10-03
( ( C y WVAP Location: RWP/WP lnrf Surve vTvwe Page I of 1t Nuclear Reactor Inside = UVA-FS-027 Final Status Surve Comments: surveyed By. Date:l Instrument Serial#0 Cal. Due !ProbeAreal Serlal i Cal. Due l Ettf. M ax P Bkg9tL fax~tatukmurryd RRco ....... Alice Thomnpsonl ow2w Tenndec t;C052 4/1WO4 nha nha We Wen nh =
!!!.t=!ftnwe !LaBsJndlr . ....... obby Leigh osntfo0 M 2221 103942 3/27/M0< 43-68 126 1ri0790l 3f27i2004 0.109 332
- =.s i'3,_,,,,,, trn 1as03 tW2221 0...............
nfo 1U4010 3F24r200 44-10 We tS0873 j 324r200Et WSn Fa Sturtyey~ O0 R BY. Deft M-2221 172051 4f1200D4 43-37 430 16137 4fWf204 0.109 Frank Myers OM 3 _=_3 W. l ?5 *Srnearxabm-Dirert nsJ j-awsarnpie t -beta dose rat inmRadth -X- x *HournJary SOP S~ntop OfPd xi9cat8ct1Z2J OSOrate# Genrwaldose ra!
Smears Stathc CountpD Coordinates
_ Gross CPM D PtWt100em' _ Utnsh/Shhtlded IDPM/10O0m' No a a a IP No. CPM Not Lc No.j North lEast lElevation See i 292 238- 29 288 1 0-7 OS 0 2 2 Agahe -2 312 26f1 371_ 274 -2 _0.7 3.5 2 3 Report 3 300 316 .11ff 302 3 O 6.5 l 2 4 4 481 383 714 332 4 O
- 0. 05
.0. 0
_ _ 5 451 308 1O041 298 15 O.Si 2 i
_ I-6 400 367 240 325 12 0-S 4.5 0
_ _ 1 7 489 324 1201 305 7 _OS a 0 a I_ 4993 301 1.442 294 8 3 .2 OS 0
9 1 S9 494 371 895 327 9 3 OS 0 0
_0 I 10 406 256 874 287 10 3 i3.5 i 0 r1 1 431 350 S90 317 -ts 3 6.5 0
-12_ 12 311 284 197 286 12 3 8.2 r 1.25 130 13 48fi 3207 1209 303 -13 4.25 .1
- 14 14 375 288 633 288 14 5.25 2 0.O 11 I 1t 35t 279 546 283 15 525 5 0-5 1_ _ Rt 301 291 -a7 289 16 5.25 i 8 i OS
-QC QC 279 1326 34M2 306 QC 5.25 j 8 j OS
= = =X=-
Form SECARP.21.2 Rev.0
N Room M020 Floor 1 meter grid Z=o 5
A 1 - 1340-15 0 Ii + AL I AL t t It L 4 - 1200-14 0 4 A-Z
- 200 240- 200-
-430 350 380 1240- 1220. 1200- 1290- 1290- 1220.
Boiler 1390 146 1500 50 143,0 1430 AL A A 3 350 4 l4 4-l44 ~
I
\ Z I I fi 4-I I I I 1180- 1200- 1200- 1180. 1260- 1150- 1180- 1170- 1200- 1170- 1270. 125 1440 133 WV 1300- 121( 1450- 1125 1310 1300 1310 1180 125( 1160 1360 1380 1570 143( l l 2 lI l-l-l-l-l l-l l l 14500 1200 1
I 4 r r r C6 Electrical Panels (D Fume Hoods n,
'V r Ir V
_ _ _ _ _I . . .
-2 -1 0 1 2 3 4 5 6 7 8.2 Survey # UVA-FS-027 Meter # L2221 172051 Beta Scan Probe# 43-37 161367 Readings in CPM o denotes smear Meter L2221 103942
- 43-68 probe used in and static count Probe 43-68 160790 inaccessible areas locations Datt A-11 -03 c (
( ( (7 Room.M020 East Wall 1 meter grid E = 8.2 3
2 13000 12700-12700-120-1210- 12300- 13300- 13200-13700 14 00 13300 12700 14500 14700 1
I III 5.2 5 4 3 2 1 0 Survey # UVA-FS-027 Gamma Scan Meter# L2221 184010 Readings in CPM Probe # 44-10 150873 Date 6-11-03
Room M020 East Wall 1 meter grid E = 8.2 3
2 341- 423- 346- 345- 414- 416-409 469 554 1 387 525 504 1
397 340- 309- 346- 468- 355-419 420 406 389 581 458 5.25 5 4 3 2 1 0 Beta Scan Survey# UVA-FS-027 Readings in CPM Meter # L2221 103942 Probe 4 43-68 160790 O denotes smear and N static count locations Date 6-11-03
( ( C
( (
Room M020 North Wall 1 meter grid N =5 3
2 389- 303- 266- 293- 250- 259 273 329-474 65 27 291-526373832 32308 356 394 394 1
410- 314- 324- 294- 333- 288- 294- 333- 2794 513 504 432 380 387 335 381 396 4
-1 0 1 2 3 4 5 6 7 8.2 Survey# UVA-FS-027 Beta Scan Meter# L2221 103942 Readings in CPM Probe # 43-68 160790 O denotes smear and E Date 6-11-03 static count locations
Room M020 South Wall 1 meter grid N=O 3
- 1 2
268- 301- 294- 288- 270- 265- 248- 261-345 357 340 378 304 294 301 305 1
281- 276- 289- 279- 249- 264- 317- 243-326 347 310 359 314 317 345 325 8.2 7 6 5 4 3 2 1 0 Survey# UVA-FS-027 Beta Scan Meter # L2221 103942 Readings in CPM Probe # 43-68 160790 O denotes smear and Date 6-11-03 static count locations
(. (, (
( (
Room M020 West Wall 1 meter grid E=-2 3
2 1
0 1 2 3 4 5 5.25 Survey # UVA-FS-027 Beta Scan Meter # L2221 103942 Readings in CPM Probe # 42-68 160790 O denotes smear and static Date 6-11-03 count locations
Room M020 North Wall 1 meter grid N=5
. .1 3
2
+ + + + + t + + + +
11900- 11000- 10800- 11300- 11500- 11300- 11500- 12000- 12000- 1270(
14 00 11 00 11300 12300 12300 12 00 12500 12 00 12700 13X 1
It I I~l
-1 0 1 2 3 4 5 6 .7 8 8.2 Survey# UVA-FS-027 Gamma Scan Meter # L2221 184010 Readings in CPM Probe# 44-10 150873 Date 6-11-03
( c c
( (
Room M020 South Wall 1 meter grid N=O 3
To
- I 11100-do 11100-T 11500-TT 10600- 90-t 9200-L 8500-T 8800- 9400-2 11900 1 900 12 00 11 00 10 00 10 00 9100 10 00 10 0 1
ttIf 8.2 8 7 6 5 4 3 2 1 0 Survey # UVA-FS-027 Gamma Scan Meter# L2221 184010 Readings in CPM Probe# 4-10 150873 E 4-Date 6-11-03
Room M020 West Wall 1 meter grid E = -2 3
2 T0800t 10800- 110-11400- t4o t
11800-12500 IS I t°°° 120001 000-12100 r1200 11300 11,900 12500 1
0
. I1:uI 1 2 3 4 5 5.25 Survey # UVA-FS-027 Gamma Scan Meter# L2221 184010 Readings in CPM Probe# 44-10 150973 N Date 6-11-03
( ( (
( (
Room M020 Floor 1 meter grid N Z =o
-2 -1 0 1 2 3 4 5 6 7 8.2 Survey # UVA-FS-027 Gamma Scan Meter#L2221 184010 Readings in Probe # 44-10 150873 CPM Date 6-11-03
( ( (
UVAP Radiological Survey Form __
Location: IRWP/WP Surv Y SurM Typ: PageIof II Nuclear Reactor Inside IUVA-FS-028 Final Status Survey Comments By Date: Instrument SerlS# Cal. Due Probe Aral Seal# Cal Due I I Elf.1 Map BkaLc WusaussBomoopeice Tompson Tmfr OS114r Trneffec i6405 4Mtrsl4W nta n/a n/a n/a nh
--- BobbyLeigh 06/12i03 M-2221 103942 3m2o2004 43-6 1126 160790 3Y/2004 0109 340 9__._.____ jason Strand 06/1203 M.2221 184010 3i24i2C04 44.10 n/a 150873 3/2412004 nta I Rrvswd By: Date:
Myers 06M&MI! t I _ _ 1 i I I I I atr sample B -beta dose rate n mRad/h -X..X.
- Boundary SOP
- Stop Off Pad _ty d cotadil2 dose rate a. General dose rat ltatic Countp
_ _ Coordinats GrossCPM I DPM/1OOcm' UnshfShietled DPIW100cm' it ji No a I B a No. CPM Net Lc Nol northI east elevation I 330 1 304 189 296 11 0 2.25 2 2 316 1 322 J-44 304 21 0 4.75 2 Report 3 371 309 451 296 31 0 1 725 2 41 604 402 1,471 340 41 15 -1.5 3 5 532 373 1.158 328 5 1 1 j 3 6 425 352 532 318 61 1 1 3.5 3 7 460 381 575 331 71 1 6 3 8 540 396 1.048 338 I 8a 1 82 2.5 S 527 321 1,500 304 9 3 -2 225
_ 10474 402 524 340 10 3 -0.25 3 1I 562 387 1.274 334 11 3 225 3 12 583 I 382 1,484 332 12 3 4.75 3 13 58 1 390 1.442 335 13 3 7.25 3 14 484 391 6t77 335 14 425 .1 2.75 15 345 340 38 313 15 5251 1 3 1 365 309 408 298 16 525 135 3 17 371 305 481 29 117 5.25 6 3 a IC 386 300 62b l 294 0 QCj 5.25j 6 3 I
I -
I
=
=
I IX 11 I 1=
Form SEC-RP-21.2 Rev.0
Room M020 East Wall 1 meter grid E = 8.2 II 3
12200-13600 2
1 5 4 3 2 1 0 Survey # UVA-FS-028 Gamma Scan Meter # L2221 184010 Readings in CPM Probe # 44-10 150873 Date 6-12-03
( ( (
( (
Room M020 East Wall 1 meter grid E = 8.2 3
2 1
5 4 3 2 1 0 Survey # UVA-FS-028 Beta Scan Meter # L2221 103942 Readings in CPM Probe # 43-68 160790 O denotes smear and Date 6-12-03 static count locations
Room M020 North Wall 1 meter grid N=5 3
1L4) 290-
- r .
)r 279-433- 330-420 423 522 387 2
1
-1 0 1 2 3 4 5 6 7 8.2 Survey # UVA-FS-028 Beta Scan Meter # L2221 103942 Readings in CPM Probe# 43-68 160790 o denotes smeax-ani
- E Date 6-12-03 static count locations
( (
C (
Room M020 South Wall 1 meter grid N=5 3
316- 250- 264-392 301 386 C3__ 0li_ 2 1
8.2 7 6 5 4 3 2 1 0 Survey# WUVA-FS-028 Beta Scan Meter # L2221 103942 Readings in CPM Probe # 43-68 160790 o denotes smear and Date 6-12-03 static count locations
Room M020 West Wall 1 meter grid E=-2 3 446-584 9I 2
I.
1 0 1 2 3 4 5 Survey # UVA-FS-028 Beta Scan Meter # L2221 103942 Readings in CPM Probe # 43-68 160790 O denotes smear and static Date 6-12-03 count locations
( (
( ( c Room M020 Ceiling 1 meter grid Z =3.1 5
4 4. 4-II 4 4. 4 367- 502- 417-416 468 588 589
-613 3
- 4. 4 4. 4.-
2 466- 4. 4. 4. 4. 4 416-416-4 423-t 66- 429- 423-494 520 613 514 X-4 4 (5) 4. +
(n) 4.
(7 4 4-1
-2 -1 0 1 2 3 4 5 6 7 8 8.2 Survey # UVA-FS-028 Beta Scan Readings in CPM N
Meter# L2221 103942 Probe# 43-68 160790 o denotes smear and static count Date 6-12-03 locations
Room M020 North Wall 1 meter grid N=5 3
12600- 10100- 10100- 10900-13900 10500 10800 11500 2
1 0 1 2 3 4 5 6 7 8.2 Survey# UVA-FS-028 Gamma Scan Meter# L2221 184010 Readings in CPM Probe # 44-10 150873 Date 6-12-03
( C (
(: (
Room M020 South Wall 1 meter grid N=O 3
11100- 10200- 9100-11800 10800 9400 2
1 8.2 7 6 5 4 3 2 1 0 Survey # UVA-FS-028 Gamma Scan Meter# L2221 184010 Readings in CPM Probe# 44-10 150873 Date 6-12-03
Room M020 West Wall 1 meter grid E = -2 3
11900-12700
+ t t *1-2 1
J & A 0 1 2 3 4 5 Survey # UVA-FS-028 Gamma Scan Meter # L2221 184010 Readings in Probe # 44-10 150873 CPM N Date 6-12-03
( ( c
C ( C Room M020 Ceiling 1 meter grid Z=3 4 _
12200- 9700- 10600- 15500 210700 11500 1T00 3 _ _ __ _ 16000__
2 6°00°- 11o00- 1050-0 11100-11300 18011900
-2 -1 0 1 2 3 4 5 6 7 8 8.2 Survey # UVA-FS-028 Gamma Scan N Meter# L2221 184010 Readings in CPM Probe # 44-10 150873 Date 6-12-03
( ( (
UVAP
_ __ Radiological Survey Formr Loain RWP _ Survey 0 SurveytTYP Page I of 25 Nuclear Reactor Inside I _ UVA-FS-029 Final Status Survey __ . __
Comments: 8 Date: Instrument Serial # Cal. Due Probe Arpe Serls # Col. Due p Etf. - M ax j Bkg Lc FaStTatSu y-Rm M006.M014.M01 MM lCi orpson 06tt703l Torneneo 64052 4/16t2004 rVa We nha = n Va 0anr M031Class 2 trwats and floor o y eig h 06tt6t03 M.2221 103942 312712004 4348 126 160790 312712004 0.109 334 SueRntti 41 _ . j M.2221 184010 3124t2004 44.10 na 150873 3124t2004 nt We
.t abDsat A:ddm 004 Rved v D : M-2221 172051 4t2Q004 43-37 430 161367 4t212004 0109 Frank Mvers 0@1tv3 M-2221 157031 3v1712004 44.10 nha 155202 31712004 nta
- Smoar to Direct Fnsh awaampI
- etadose et.L a rate in mRads/ .X-X--* Boundan SOpF StepOtf Pad Elitt *lU12 dose rate C* General dose ra Smears_ _ _ Static Count 5- Coordinatste-
-. CPM I DPWIMOOcm'
- 5 Gross UnshfShleldod I DPM1OOcm' N0o. a _ I No. CPM I Net lic i North I East I Elevatton See _ = 4 91 1 332 1t.158 11 309 1 *8 1 28551 1.5 284 311 *197 299 *3.5 23.3 3 Repor 3 298 323 l182 305 l 3 .1.3 26.5 2 4 4 370 388 *131 334 _4 .3.5 30.5 0 5 5 312 339 *197 312 5 .3.2 34.5 0 6 6 350 354 .29 319 6 *3.2 38.5 0 7 7 395 363 2 323 7 .3.2 42.5 0 8 8 330 348 .131 316 8 0.5 0.5 0 9 9 304 331 .197 309 9 0.5 4.5 0 10 101 321 1 337 1 .116 311 101 os 1 8.5 0 11 I 11 321 324 -22 305 11I 0.5 125 0 12 12 302 365 i459 324 12 0.5 16.5 0 13 -13 333 296 269 292 13 0.5 20.5 0 14 14 356 337 138 311 14 05 24.5 0 15 15 347 326 153 308 15 0.5 2a.5 0 16 16 343 313 218 300 16 4.5 26.5 0 17 17 335 285 364 286 17 2.5 28 1.75 OC i I IC 326 I 287 1 284 287 VC 2.5 28 1.75 191 _ 1S 291 1 308 1109 297 19 t1.2 1 43.5 1.5 20 20 490 343 1.070 314 20 .8 1 43.5 0.5 21 21 354 337 124 311 1 0.5 302 1S 221 22 360 322 277 304 22 1.6 22.5 1 23 2 23_ 306 273 240 280 23 -6.5 28.5 1.5 24 2 461 300 1.172 294 24 0 15.5 0.5 25 25 305 27m 204 282 25 1.6_ 18 2 26 26 451 295 1.136 291 26 0 6.5 0.5 27 27 270 254 116 270 27 1.6 9.5 1 26 ii 28 445 304 1.027 296 28 1.6 3.5 2 29 29 325 j30 138 297 29 .5.5 43.7 1 ac CC 320 294 189 291 UC *5.5 43.7 1 I
I' Form SEC-RP-21.2 Rev.0
Room M006,Room M015 and M014 Floor 1 meter grid 6 Z=o RoomMO15 I
'*922..1008*O 1f Ii r21 AL 5 t1 L N © 910-984 4
I 3 958-1027 938-1014 1407-1432 2
'41507-1567 Room M014 r r *.- 1383-1513 -..
- 1.3 26.1 27 27.6 28.9 Survey # UVA-FS-029 Beta Scan Meter # L2221 172051 Readings in CPM
.Probe # 43-37 161367 0 denotes smear and Date 6-16-03 static count locations C C c
( (
Room M03 1 West End Floor Z=o 1.6 I- -871-960 1
-843-948 .
1
_ _ (2) -812-952 _io)
I I I 844-959 - 4 1 0 1 2 3 4 5 6 7 8 9 IC E
Survey # UVA-FS-029 Beta Scans Meter # L2221 172051 Readings in CPM Probe# 43-37 161367 o denotes smear Date 6-16-03 and static count locations
Room M03 1 East End Floor Z=o 1.6 I I T T889-1002 l 1 1 4 _ 91-9816 _ _
4- ii 793-957 (ix I1775-962 -*1lo 0
10 11 12 13 14 15 16 17 18 19 20 Survey # UVA-FS-029 Beta Scan Meter # L2221 172051 Readings in CPM Probe # 43-37 161367 0 denotes smear and Date 6-16-03 static count locations
( ( (
( (
Room M03 1 North Wall East 1 meter grid N= 1.6 3
2 TTT I -
205 244-297 T
_10800-1
_< <m flC__
0 10 11 12 13 14 15 16 17 18 19 20 Survey# UVA-FS-029 Beta and Gamma Scans Meter# L2221 103942 Readings in CPM Probe# 43-68 160790 O denotes smear and Meter # L2221 *157031 static count locations Probe # 44-10
- 155202 Date 6-17-03
Room M03 1 South Wall West 1 meter grid N=O 3
2 1
120 345-426 11500-
~rr< I 0 10 9 8 7 6 5 4 3 2 1 0 E
(. (
( (
Room M03 1 South Wall east 1 meter grid N=O 3
2 1
256 (
406 110500-0 20 19 18 17 16 15 14 13 12 11 10 Survey# UVA-FS-029 Beta and Gamma Scans Meter# L2221 103942 Readings in CPM Probe# 43-68 160790 0 denotes smear and Meter# L2221 *157031 static count location Probe# 44-10 *155202 Date 6-17-03
Room M03 1 North Wall West 1 meter grid N= 1.6 3
2 357-U88 10500-446 11900 10700- 264- C27 1
_ _5Q D _--__32I 0 2 4 5 6 7 8 9 10 0 1 3 Survey # UVA-FS-029 Beta and Gamma Scans Meter # L2221 103942 Reading in CPM Probe# 43-68 160790 O denotes smear and static Meter# L2221 *157031 count locations Probe# 44-10 *155202 Date 6-17-03
( C (
( (
Room M03 1 West End Floor Z=o 1.6 II I4 H10300- 1 1 _ _IQ I20I _
__10500- __ I__ ________
I 1 12200 0 1 2 3 4 5 6 7 8 9 IC E
Survey# UVA-FS-029 Gamma Scan Meter# L2221 184010 Readings in CPM Probe# 44-10 150873 Date 6-16-03
Room M03 1 East End Floor Z=o 1.6
_ - 10400-121 0NO_ __ _ _ __ _ _
1 4 -10400-123 0.
I .fAff I11 0
10 11 12 13 14 15 16 17 18 19 20 E
Survey# UVA-FS-029 Gamma Scan Meter# L2221 184010 Readings in CPM Probe# 44-10 150873 Date 6-16-03
( C c
( (7 Room M030 North Wall West 1 meter grid N= 1.6 3
300 316 2
363 405
- 13000 1 i0 11II200-1 __ __ _1442 0 0 _ __ __ _ __ __ _
S20 J
0 25 26 27.5 28 29 30 30.6 20 21 22 23 24 Survey# UVA-FS-029 Beta and Gamma Scans E Meter # L2221 103942 Readings in CPM Probe # 43-68 160790 O denotes smear and static Meter # L2221
- 157031 count locations Probe # 44-10 *155202 Date 6-17-03
M030 North Wall East 1 meter grid N = -1.2 3
2 239-309 1*10800-1 0
42.6 43 44 44.6 E
Survey# UVA-FS-029 Beta and Gamma Scans Meter # L2221 103942 Readings in CPM Probe # 43-68 160790 o denotes smear and static count Meter # L2221 *157031 locations Probe # 44-10 *155202 Pie 6-17-03
(
( ( (
Room M030 South Wall 1 meter grid N=-8 3
3 N =-4.6 52j 2 2 467-
" 12100-1 -11 Sink N = -0.3
-Y I N = -1.3 I I 3
' 30.6 30 29 28.
___________ 4 2
- 11300-E 369 12400
- 11600- 277-Q _
132QQO 329~ 1 0
Survey # UVA-FS-029 28 27 26 25 24 23 22 21 20 28.5 Meter# L2221 103742 Probe# 43-68 160790 Beta and Gamma scans Meter# L2221 *157031 Readings in CPM Probe# 44-10 *155202 o denotes smear and static Date 6-16-03 count locations
Room M030 South Wall East 1 meter grid N=-8 3
- 2
- 1 74-38
- 12300-
.14E9D 42.0 43.7 43 42.6 E .4 Survey # UVA-FS-029 Beta and Gamma Scans Meter # L2221 103942 Readings in CPM Probe# 43-68 160790 O denotes smear and static count Meter# L2221 *157031 locations Probe # 44-10 *155202 Date 6-17-03
( ( (
c C Room M030 West Wall 1 Meter grid E=23.3 E =28.5 3
2 258-339g 11 fu5C *11500..
1 1I1 Q0_
0 i <
-4.6 -4 3 -2 .03 -8 -7 -6 -5 3 1 Survey# UVA-FS-029 Beta and Gamma Scans Meter# L2221 103942 Readings in CPM Probe# 43-68 160790 o denotes smear and static Meter# L2221 *157031 count locations Probe# 44-10 *155202 Date 6-17-03
Room M030 East Wall 1 meter grid E =44.6 3
2 -* 11200-12300
- 250-319 2091 1
-2 -2.5 -3 -4 -5 7 -8 Survey# UVA-FS-029 Beta and Gamma Scans Meter # L2221 103942 Readings in CPM N .4 Probe# 43-68 160790 o denotes smear and static Meter# L2221 *157031 count locations Probe# 44-10 *155202 Date 6-17-03
( ( (
( ( (
Room M030 Middle Section Z =o
-2.8
-3 II -I I (5) -806-95/ I 1 (6) 1
-3.5 34 35 36 37 38 39 40 41 42 30.8 31 32 33 N
Survey # UVA-FS-029 Beta Scan Meter# L2221 172051 Readings in CPM Probe# 43-37 161367 O denotes smear and static count Date 6-16-03 locations
M030 East Floor 1 meter grid
-1.2 4 Z=o 44
-2 l . l 1236-
-2.8 1399
-3 F
0 1298-1323
-3.6
-4
- p. N A
1204. 44.6 1230 1394 1290 42
-5 1231-1276
-6
-7 Survey # UVA-FS-029 Meter # L2221 172051 Probe # 43-37 161367 -8 Date 6-16-03 Beta Scan Readings in CPM O denotes smear and LI static cr -t locations 42.6 43 44
( (
( (
Room M030 West End Floor Z=o 1.6
-II' I9A'V, 1 -A t 1 ...... 9......
I I - .
O.
4 4 4 895-961 844-1061 A
0
- 4 4 4
4 836-1040 9 4 4
+
+I >
4 4 -
-0.3 938-1001 20.3 21 22 23 -9 + 4 4 4 4-4-9-4-4 -1 u-I 922- I.-.
I 1020
-2 t 25 26 27 28 877- 930 909- I N 950 93 10?6
-3 -3 A 924- 924-I -4.
-4.6 24
-4
-5 P 1022 P
I A
C E
II 1107 838-Survey # UVA-FS-029 Beta Scan -6 962-Meter # L2221 172051 Readings in CPM 1011 Probe# 43-37 161367 o denotes smear and static -7 Date 6-16-03 count locations
-8 I Sink __ _ _
28.5 29 30 30.8
Room M030 Middle Section Z =o
-2.8
-3 14 10000-125r0 II
-3.5 30.8 31 32 33 34 35 36 37 38 39 40 41 42 N
Survey # UVA-FS-029 Gamma Scan Meter# L2221 184010 Readings in CPM Probet# 44-10 150873 Date 6-16-03
( ( (
( ( (
M030 East Floor 1 meter grid
-1.2 Z=o AL A
-2 10800-
-2.8 123.00 F
-3.6
-4 N 44.6 10600-42 14500
-5 l4 * ~
-6
-7 Gamma Scan Readings in CPM
.N-
-8 Survey # UVA-FS-029 Meter # L2221 184010 Probe # 44-10 150873 Date 6-16-03 42.6 43 44
Room M006 East Wall 1 meter grid E = 28.6 E= 27.5 3
i 2
- 287-i *9000-1 _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 10 7 0 0_ _ _ _ _ _ _ _ _
RomI1 0
5 4 3 2 1 1.3 Survey # UVA-FS-029 Beta and Gamma Scans Meter # L2221 103742 Readings in CPM Probe# 43-68 160790 O denotes smear and static Meter# L2221 *157031 count location Probe# 44-10 *155202 Date 6-16-03
( (I (
( ( (
Room M030 West End Floor Z=0 1.6 _
A , L A I 1
T T
11400- 12200- 12200- 12400-12600 13500 13900 14200 I I I 0
_ 12600 11900- 12300- 11800- 10900- l
-0.3 13700 13200 13300 13200 12900 2C1.3 21 22 23 I I I
-1 F '4, r
-2 t 25 26 27 28 _ I 10700- 10200-N 10900-13300 13500 12500
-3 -3 I -4
-4.6 24
-4
-5
-ri L
E S
I Survey # UVA-FS-029 Gamma Scan -6 10900 Meter I L2221 184010 Readings in 12701 Probe # 44-10 150873 CPM -7 Date 6-16-03 Sink
-8 1 28.5 29 30 30.8
Room M006,Room M015 and M014 Floor 1 meter grid 6 Z=o 5.
I N
4 3
2 1.3 26.1 27 27.6 28.9 Survey # UVA-FS-029 Beta Scan Meter # L2221 172051 Readings in CPM Probe 4 43-37 161367 O denotes smear and Date 6-16-03 static count locations c ( (
( ( (
Room M006,Room M015 and M014 Floor 1 meter grid 6 Z=o 5
N 4
3 2
1.3 26.1 27 27.6 28.9 Survey # UVA-FS-029 Gamma Scan Meter# L2221 184010 Readings in CPM.
Probe# 44-10 150873 Date 6-16-03