ML041700261
| ML041700261 | |
| Person / Time | |
|---|---|
| Site: | Grand Gulf |
| Issue date: | 06/16/2004 |
| From: | NRC/NRR/DLPM |
| To: | |
| References | |
| TAC MC2177 | |
| Download: ML041700261 (3) | |
Text
PAM Instrumentation 3.3.3.1 SURVEILLANCE REQUIREMENTS
NOTE---------------------------------------
These SRs apply to each Function in Table 3.3.3.1-1.
SURVEILLANCE FREQUENCY SR 3.3.3.1.1 Perform CHANNEL CHECK.
31 days SR 3.3.3.1.2 Deleted SR 3.3.3.1.3
NOTE-------------------
Neutron detectors are excluded.
Perform CHANNEL CALIBRATION.
18 months I
I GRAND GULF 3.3 -21 Amendment No. 41-°, 166
PAM Instrumentation 3.3.3.1 Table 3.3.3.1-1 (page 1 of 1)
Post Accident Monitoring Instrumentation CONDITIONS REFERENCED FROM REQUIRED REQUIRED FUNCTION CHANNELS ACTION D.1
- 1. Reactor Vessel Pressure 2
E
Wide Range 2
E
Fuel Zone 2
E
- 4. Suppression Pool Water Level 2
E
- 5. Suppression Pool Sector Water Temperature 2(c)
E
- 6. Drywell Pressure 2
E
- 7. Drywell Temperature 2
E B. CRD Cavity Temperature 2
E
- 9. Primary Containment Pressure -
Wide Range 2
E
- 10. Primary Containment Pressure -
Narrow Range 2
E
- 11. Primary Containment Air Temperature 2
E
- 12. Primary Containment Area Radiation 2
F
- 13. Drywell Area Radiation 2
F
- 14. Deleted
- 15. Deleted
- 16. Penetration Flow Path, Automatic PCIV Position 2 per pene traffhn E
flow path I
I (a)
Not required for isolation valves whose associated penetration flow path is isolated.
(b) Only one position indication channel is required for penetration flow paths with only one installed control room indication channel.
(c) Monitoring each of six sectors.
GRAND GULF
- 3. 3 -22 Amendment No. X4j6_
Deleted l 3.6.3.1 3.6 CONTAINMENT SYSTEMS 3.6.3.1 Deleted Pages 3.6-35 and 3.6-36 have been deleted I
I GRAND GULF 3.6-35/3.6-36 Amendment No. 44, 166