Nonradiological Aquatic Monitoring Program Biological Monitoring
ML041670392
Person / Time
Site: Sequoyah  
Issue date: 06/10/2004
From: Howard S
Tennessee Valley Authority
To: Hannah C
Office of Nuclear Reactor Regulation, State of TN, Dept of Environment & Conservation
References
TN0026450
Download: ML041670392 (35)


Text

Tennessee Valley Authority, Post Office Box 2000, Soddy-Daisy, Tennessee 37384-2000 June 10, 2004 State of Tennessee Department of Environment and Conservation Division of Water Pollution Control Enforcement & Compliance Section 6th Floor, L & C Annex 401 Church Street Nashville, Tennessee 37243-1534 Attention: Mr. Chip Hannah

Dear Mr. Hannah:

SEQUOYAH NUCLEAR PLANT - NONRADIOLOGICAL AQUATIC MONITORING PROGRAM BIOLOGICAL MONITORING Please find enclosed two copies of the report, *Biological Monitoring of the Tennessee River Near Sequoyah Nuclear Plant Discharge, 2003.' This report is submitted in accordance with Part l1l, Section F of the TVA - Sequoyah Nuclear Plant NPDES Permit No. TN0026450.

Please contact me at (423) 843-6700 if you have any questions or comments.

Sincerely,

)tsl Gr-LY C Stephanie A. Howard Principal Environmental Engineer Signatory Authority for J. Randy Douet Site Vice President Sequoyah Nuclear Plant Enclosure cc (Enclosure):

Chattanooga Environmental Assistance Center Division of Water Pollution Control State Office Building, Suite 550 540 McCallie Avenue Chattanooga, Tennessee 37402-2013 Mr. Clarence Coffey Tennessee Wildlife Resources Agency 464 Industrial Boulevard Crossville, Tennessee 38555 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555 Petrs n] W'ecKcI' Nt_

Biological Monitoring of the Tennessee River Near Sequoyah Nuclear Plant Discharge 2003 by Dennis S. Baxter Kenny D. Gardner Donny Lowery June2004 Final Aquatic Biology Lab Norris, Tennessee

Table of Contents Page Introduction 1

Methods 2

Fish Community 2

Benthic Macroinvertebrate Community 4

Sport Fishing Index 4

Spring Sport Fish Survey 5

Results and Discussion 5

Fish Community 5

Benthic Macroinvertebrate Community 6

Sport Fishing Index 6

Spring Sport Fish Survey 6

Literature Cited 8

List of Tables Table 1.

Scoring Results for the Twelve Metrics and Overall Reservoir Fish Assemblage Index for Chickamauga Reservoir at the Sequoyah Downstream Sampling Station, 2003.

9 Table 2.

Scoring Results for the Twelve Metrics and Overall Reservoir Fish Assemblage Index for Chickamauga Reservoir at the Upstream Sampling Station, 2003.

10 Table 3.

Recent (1993-2003) RFAI Scores Collected as Part of the Vital Signs Monitoring Program Upstream and Downstream of Sequoyah Nuclear Plant.

11 Table 4.

Species Listing and Catch Per Unit Effort for the Embayment and Sequoyah Transects During the Fall Electrofishing and Gill Netting on Chickamauga Reservoir, 2003 (Electrofishing Effort = 300 Meters of Shoreline and Gill Netting Effort = Net-Nights).

12 Table 5.

Species Listing and Catch Per Unit Effort for the Transition and Inflow Transects During the Fall Electrofishing and Gill Netting on Chickamauga Reservoir, 2003 (Electrofishing Effort = 300 Meters of Shoreline and Gill Netting Effort = Net-Nights).

13 i

List of Tables (continued)

Page Table 6.

Individual Metric Ratings and the Overall Benthic Community Index Score for Upstream and Downstream Stations near Sequoyah Nuclear Plant, Chickamauga Reservoir, November 2003.

15 Table 7.

Average Mean Density Per Square Meter of Benthic Taxa Collected at Upstream and Downstream Stations near Sequoyah Nuclear Plant, Chickamauga Reservoir, November 2003.

16 Table 8.

Recent (1994-2003) Benthic Index Scores Collected as Part of the Vital Signs Monitoring Program at Chickamauga Reservoir Transition (TRM 490.5 and TRM 482) and Forebay Zone (TRM 472.3) Stations.

19 Table 9.

Sport Fishing Index Results for Chickamauga Reservoir, 2003.

19 Table 10.

Sport Fishing Index Population Quantity and Creel Quantity and Quality Metrics and Scoring Criteria.

20 Table 11.

Sport Fishing Index Population Quality Metrics and Scoring Criteria.

22 Table 12.

Electrofishing Catch Rate, Mean Weight, Percent Harvestable, Numbers of Black Bass Greater than Five Pounds, Numbers of Black Bass Greater than Four Pounds and Largest Black Bass Collected, Chickamauga Reservoir Black Bass Surveys, 1995-2003.

22 Table 13.

Black Bass Catch Per Hour Compared to Habitat Types by Location.

23 Table 14.

Black Bass Catch Per Hour Compared to Habitat Types by Reservoir.

23 List of Figures Figure 1.

Parameters used to calculate the Sport Fishing Index (SFI).

24 Figure 2.

RFAI scores from sample years between 1993 and 2003.

25 Figure 3.

Sport Fishing Index results for Chickamauga Reservoir between 1997 and 2003.

26 Figure 4.

Chickamauga Reservoir length frequency histogram, (all sites) spring 2003.

27 Figure 5.

Relative stock density values for Tennessee River Reservoirs.

28 ii

- I List of Figures (continued)

Page Figure 6.

Proportional stock density values for Tennessee River Reservoirs.

29 Figure 7.

Chickamauga Reservoir mean relative weights (Wr) for largemouth bass broken out by RSD category and fish numbers.

30 Acronyms BI Benthic Macroinvertebrate Index BIP Balanced Indigenous Population NPDES National Pollutant Discharge Elimination System PSD Proportional Stock Density QA Quality Assurance RFAI Reservoir Fish Assemblage Index RSD Relative Stock Density RSDM Relative Stock Density of Memorable-sized RSDP Relative Stock Density of Preferred-sized RSDT Relative Stock Density of Trophy-sized SAHI Shoreline Assessment Habitat Index SFI Sport Fishing Index SQN Sequoyah Nuclear Plant SSS Spring Sport Fish Survey TRM Tennessee River Mile TVA Tennessee Valley Authority VS Vital Signs Wr Relative Weight iii

Introduction Section 316(a) of the Clean Water Act specifies that industrial, municipal, and other facilities must obtain permits if their discharges go directly to surface waters. Industries responsible for point-source dischargers of heated water can obtain a variance from state water quality standards if the industry can demonstrate compliance with thermal criteria by documenting the maintenance of Balanced Indigenous Populations (BIP) of aquatic life in the vicinity of its discharge. Sequoyah Nuclear Plant's (SQN) current National Pollutant Discharge Elimination System (NPDES) permit number TN0026450 states, "For Section 316(a), the permittee shall summarize previous data and indicate whether significant changes have occurred in plant operation, reservoir operations or in stream biology that would necessitate that significant changes to the permitted variance." The permittee shall use the Reservoir Fish Assemblage Index (RFAI) to assess Chickamauga Reservoir fish community health. Any apparent declines in the fish community health will be further investigated to discover whether the decline is a valid conclusion and if the decline is real to identify possible sources for the fish community decline.

As part of the identification of potential sources for the decline, the instream effects of the discharges made under this permit will be investigated (TDEC 2000). In response to this requirement, Tennessee Valley Authority's (TVA's) Vital Signs (VS) monitoring program (Dycus and Meinert 1993) will be used to evaluate areas of Chickamauga Reservoir upstream and downstream of SQN discharge. The purpose of this document is to briefly summarize and provide Tennessee Department of Environment and Conservation the results of comparisons between current and historical monitoring data.

Prior to 1990, TVA focused on reservoir ecological assessments to meet specific needs as they arose. In 1990, TVA instituted a Valley-wide VS monitoring program which is a broad-based evaluation of the overall ecological conditions in major reservoirs. Data is evaluated with a multi-metric monitoring approach utilizing five environmental indicators: dissolved oxygen, chlorophyll, sediment quality, benthic macroinvertebrate community, and the fish community.

When this program was initiated, specific evaluation techniques were developed for each indicator, and these techniques were fine-tuned to better represent ecological conditions. The outcome of this effort was development of multi-metric evaluation techniques for the fish assemblage (i.e., RFAI) and the benthic community, as described below. These multi-metric evaluation techniques have proven successful in TVA's monitoring efforts as well as other federal and state monitoring programs. Therefore, they will form the basis of evaluating these monitoring results. For consistency, only RFAI analyses between 1993 and 2003 will be utilized.

The Benthic Macroinvertebrate Index (BI) is used primarily to support the RFAI analysis.

In the past, the Sport Fishing Index (SFI) was used in support of a thermal variance request at SQN (TVA 1996). The SFI was developed to quantify sport fishing quality for individual sport fish species. The SFI provides biologists with a reference point to measure the quality of a sport fishery. Comparison of the population sampling parameters and creel results for a particular sport fish species with expectations of these parameters from a high quality fishery (reference conditions) allows for the determination of fishing quality. Indices have been developed for 1

black bass (largemouth, smallmouth and spotted bass), sauger, striped bass, bluegill, and channel catfish. Each SFI relies on measurements of quantity and quality aspects of angler success and fish population characteristics.

In recent years, SFI information has been used to describe the quality of the resident fishery in conjunction with compliance monitoring, thermal variance requests, and other regulatory issues at TVA nuclear plants in Tennessee. Similar NPDES compliance monitoring programs using the methodologies described above are also being performed at Colbert and Widows Creek Fossil Plants in Alabama.

The TVA Spring Sport Fish Survey (SSS) is conducted to evaluate the sport fish population of TVA Reservoirs. The results of the survey are used by state agencies to protect, improve and assess the quality of sport fisheries. Predominant habitat types in the reservoir are surveyed to determine sport fish abundance. In addition to accommodating TVA and state databases, this surveying method aligns with TVA Watershed Team and TVA's Reservoir Operations Study objectives. Sample sites are selected using the shoreline habitat characteristics employed by the Watershed Teams. The survey predominantly targets three species of black bass; (largemouth, smallmouth, and spotted bass) and black and white crappie. These species are the predominant sport fish sought after by fisherman.

Methods Fish Communitv Reservoirs are typically divided into three zones for VS Monitoring - inflow, transition and forebay. The inflow zone is generally in the upper reaches of the reservoir and is riverine in nature; the transition zone or mid-reservoir is the area where water velocity decreases due to increased cross-sectional area, and the forebay is the lacustrine area near the dam. The Chickamauga Reservoir inflow zone is located at Tennessee River Mile (TRM) 529.0; the transition zone is located at TRM 490.5, and the forebay zone is located at TRM 472.3. The VS transition zone, which is located approximately 7.2 river miles upstream of the SQN discharge (TRM 483.3), will be used to provide upstream data for the 316(a) thermal variance studies performed in sample years between 1993 and 2003. An additional transition station was later added downstream of the SQN discharge to more closely monitor Chickamauga Reservoir aquatic communities in close proximity to the SQN thermal effluent. This station is located at TRM 482.0 and will be used for downstream comparisons of aquatic communities for the 1999 through 2003 sample seasons. The forebay zone, will serve as the downstream station for 1993 through 1995 and 1997 sample seasons.

Fish samples consisted of fifteen 300-meter electrofishing runs (approximately 10 minutes duration) and ten experimental gill net sets (five 6.1 meter panels with mesh sizes of 2.5, 5.1, 7.6, 10.2, and 12.7 cm) per station. Attained values for each of the 12 metrics were compared to reference conditions for transition zones of mainstream Tennessee River reservoirs and assigned scores based upon three categories hypothesized to represent relative degrees of degradation:

2

least degraded -5; intermediate -3; and most degraded -1. These categories are based on "expected" fish community characteristics in the absence of human-induced impacts other than impoundment. Individual metric scores for a station are summed to obtain the RFAI score.

Comparison of the attained RFAI score from the potential impact zone to a predetermined criterion has been suggested as a method useful in identifying presence of normal community structure and function and hence existence of a BIP. For multi-metric indices, two criteria have been suggested to ensure a conservative screening for a BIP. First, if an RFAI score reaches 70 percent of the highest attainable score (adjusted upward to include sample variability), and second, if fewer than half of RFAI metrics potentially influenced by thermal discharge receive a low (1) or moderate (3) score, then normal community structure and function would be present indicating that a BIP existed. Under these conditions, the heated discharge would meet screening criteria and no further evaluation would be needed.

The range of RFAI scores possible is from 12 to 60. As discussed in detail below, the average variance for RFAI scores in TVA reservoirs is 6 (+/- 3). Therefore, any location that attains an RFAI score of 45 (42 + our sample variance of 3) or higher would be considered to demonstrate a BIP. It must be stressed that scores below this endpoint do not necessarily reflect an adversely impacted fish community. The endpoint is used to serve as a conservative screening level; for example, any fish community that meets these criteria is obviously not adversely impacted.

RFAI scores below this level would require a more in-depth look to determine if a BIP exists. If a score below this criterion is obtained, an inspection of individual RFAI metric results would be an initial step to help identify if SQN operation is a contributing factor. This approach is appropriate if a validated multi-metric index is being used and scoring criteria applicable to the zone of study are available.

Upstream/downstream stations comparisons can be used to identify if SQN operation is adversely affecting the downstream fish community as well. A similar or higher RFAI score at the downstream station compared to the upstream (control) station is used as one basis for determining presence/absence of SQN operational impacts on the resident fish community.

Definition of "similar" is integral to accepting the validity of these interpretations.

The Quality Assurance (QA) component of VS monitoring deals with how well the RFAI scores can be repeated and is accomplished by collecting a second set of samples at 15-20 percent of the stations each year. Experience to date with the QA component of VS shows that the comparison of RFAI index scores from 54 paired sample sets collected over a seven year period ranged from 0 to 18 points, the 75th percentile was 6, the 90th percentile was 12. The mean difference between these 54 paired scores is 4.6 points with 95 percent confidence limits of 3.4 and 5.8. Based on these results, a difference of 6 points or less is the value selected for defining "similar" scores between upstream and downstream fish communities. That is, if the downstream RFAI score is within 6 points of the upstream score, the communities will be considered similar. It is important to bear in mind that differences greater than 6 points can be expected simply due to method variation (25 percent of the QA paired sample sets exceeded that value). When this occurs, a metric-by-metric examination will be conducted to determine what caused the difference in scores and the potential for the difference to be thermally related.

3

Benthic Macroinvertebrate Community Ten benthic grab samples were collected at equally spaced points along the upstream and downstream transects. A Ponar sampler was used for most samples but a Peterson sampler was used when heavier substrate was encountered. Collection and processing techniques followed standard VS procedures. Bottom sediments were washed on a 533 1 screen and organisms were then picked from the screen and remaining substrate and identified to Order or Family level in the field using no magnification. Benthic community results were evaluated using seven community characteristics or metrics. Results for each metric were assigned a rating of 1, 3, or 5 depending upon how they compared to reference conditions developed for VS sample sites. The ratings for the seven metrics were summed to produce a total benthic score for each sample site.

Each reservoir section (inflow, transition, or forebay) differs in their maximum potential for benthic diversity; thus, the criteria for assigning metric ratings were adjusted accordingly such that the total benthic scores from sites on different reservoir sections are comparable. Potential scores ranged from 7 to 35. Ecological health ratings ("Poor," "Fair," or "Good") are then applied to scores. A similar or higher benthic index score at the downstream site compared to the upstream site is used as basis for determining if SQN's thermal discharge is having no effect on the Chickamauga Reservoir benthic community.

The QA component of VS monitoring shows that the comparison of benthic index scores from 49 paired sample sets collected over a seven year period ranged from 0 to 14 points, the 75th percentile was 4, the 9 0th percentile was 6. The mean difference between these 49 paired scores is 3.1 points with 95 percent confidence limits of 2.2 and 4.1. Based on these results, a difference of 4 points or less is the value selected for defining "similar" scores between upstream and downstream benthic communities. That is, if the downstream benthic score is within 4 points of the upstream score, the communities will be considered similar and it will be concluded that SQN has had no effect. Once again, it is important to bear in mind that differences greater than 4 points can be expected simply due to method variation (25 percent of the QA paired sample sets exceeded that value). When this occurs, a metric-by-metric examination will be conducted to determine what caused the difference in scores and the potential for the difference to be thermally related.

Sport Fishing Index Calculations described by Hickman (2000) were used to compare SFI values for selected quantity and quality parameters from creel and population samples to expected values that would occur in a good or high quality fishery. Quantity parameters include angler success and catch per unit effort from standard population samples (electrofishing, trap and experimental gill netting).

Population quality is based on measurement of five aspects of each resident sport fish community. Four of these aspects address size structure (proportional number of fish in each length group) of the community, Proportional Stock Density (PSD), Relative Stock Density of Preferred-sized fish (RSDP), Relative Stock Density of Memorable-sized fish (RSDM), and Relative Stock Density of Trophy-sized fish (RSDT) (Figure 1). Relative weight (Wr), a measure of the average condition of individual fish makes up the fifth population quality aspect.

As described by Hickman (2000), observed values were compared to reference ranges and assigned a corresponding numerical value. The SFI value is calculated by adding up the scores for quantity and quality from existing data and multiplying by two when only creel or population 4

data are available. Species received a low score when insufficient numbers of individuals were captured to reliably determine proportional densities or relative weights for particular parameters.

SFI scores are typically compared to average Tennessee Valley reservoir scores; however, Valley-wide scores are unavailable from natural resource agencies. Therefore, Chickamauga Reservoir fish species scores will be compared to previous years.

Spring Sport Fish Survey A SSS was conducted on Chickamauga Reservoir March 24-27, 2003. The summer pool level for Chickamauga is 682.5 msl and the level during the sample period was measured at 676.4 msl.

Twelve sites at three locations including Harrison Bay, Ware Branch and Sale Creek were sampled using boat-mounted electrofishers. TVA Fisheries Biologists use electrofishing equipment to sample fish at selected locations. In that process an electric current is used to temporarily stun the fish so they float to the surface of the water. The fish are collected with nets, counted, weighed, measured, and released unharmed. Each run consisted of thirty minutes of continuous electrofishing, a total of eighteen hours, in the littoral zones of prominent habitat types represented in the reservoir.

Results of the SSS monitoring were calculated using Shoreline Assessment Habitat Index (SAHI), Relative Stock Density (RSD), PSD, and Wr.

Habitat type is evaluated using the SAHI metric and is a critical component incorporated into the spring sport fish survey. The resultant habitat designations (good, fair and poor) are correlated to black bass abundance (numbers/hour).

RSD is the number of fish greater than a minimum preferred length in a stock divided by the number of fish greater than or equal to a minimum stock size.

PSD is the number of fish greater than or equal to a minimum quality length in a sample divided by the number of fish greater than or equal to a minimum stock length.

Wr is an index that quantifies fish condition and the preferred range value is 90-105% for moderate density bass populations such as those found in the Tennessee Valley latitudes.

Results and Discussion Fish Community In the autumn of 2003, the SQN downstream station scored 45 (Good) and the upstream station scored 42 (Good) using the RFAI analysis methodology (Tables 1 and 2). RFAI scores obtained from VS monitoring stations located upstream and downstream of the SQN discharge over the past several years have revealed consistently good fish community results (Table 3 and Figure 2).

Regardless of which downstream station was used, the upstream station rating remained in the "Good" range and the downstream continued in the "Good" range, on average (Table 3 and Figure 2). As indicated in Table 3, between 1993 and 2003, the average RFAI score for the upstream station was 46 (76.6 percent of the maximum score). The two downstream stations (i.e., SQN transition and forebay) both averaged 46 (76.6 percent of the maximum score).

5

Electrofishing and gill netting catch rates for individual species from the downstream station are listed in Table 4 and 5. Based on the average upstream and downstream RFAI scores, 2003 macroinvertebrate community data, and the defining characteristics for a BIP, it can be concluded that SQN operation has had no impact on the Chickamauga Reservoir resident fish community, on average, for nine sampling seasons (Table 3).

Benthic Macroinvertebrate Community Table 6 provides ratings for each metric as well as the overall benthic index score for both monitoring sites. Table 7 summarizes density by taxon at the upstream (TRM 490.5) and downstream (TRM 482) collection stations. In the 2003 sampling season, the upstream station benthic index scores were similar indicative of a BIP. The upstream and downstream comparisons produced benthic index scores of 31 (Good) and 29 (Good), respectively.

Therefore, it appears that SQN has had no adverse effect on the benthic macroinvertebrate community immediately downstream from the plant. Table 8 provides benthic index scores from VS monitoring at the forebay (TRM 472.3) and transition zone stations from 1994 to 2003. The Chickamauga forebay zone sample station is of sufficient distance downstream (11 miles) that results would not be expected to reflect plant effects. The similar scores from TRM 472.3 and TRM 482 also indicate that SQN has had no effect on the macroinvertebrate community immediately downstream from the plant (Table 8).

Sport Fishing Index In the autumn of 2003, Chickamauga Reservoir's sport fish population received similar SFI scores compared to the seven year average. Black bass, largemouth bass, smallmouth bass, spotted bass, crappie and white bass received higher scores than their seven year averages (Table 9 and Figure 3). Both sauger and striped bass received lower scores in 2003 compared to scores in 2002. The score for sauger was the lowest it has been since 1997 when this analysis technique was implemented by TVA. This quality assessment is not necessarily indicative of a trend.

Historical data indicates that SFI scores typically vary across years. However if future scores would continue to decline, further investigation would be warranted. Channel catfish, crappie and white bass received their highest SFI scores to date. Crappie and white bass scores increased from 38 to 42 and 30 to 40, respectively (Table 9 and Figure 3). Tables 10 and 11 illustrate sport fish index scoring criteria for population metrics and creel quantity and quality.

Sauger, striped bass, and channel catfish are easily caught during their spring migration to preferred spawning habitats. Fishing creel surveys conducted in the spring would better describe and evaluate these species compared to only using autumn fisheries surveys.

Spring Sport Fish Survey The sampling yielded 1,118 black bass; of these, 65.8% were harvestable size (10" or greater).

Of the total black bass collected, 847 were largemouth, 239 were spotted and 32 were smallmouth bass. Overall catch rate (62.0 fish/hr.) was slightly higher than the 2002 survey (57.4/hour) (Table 12). The average weight of harvestable sized black bass was 1.3 pounds. The largest black bass collected were two 6.4 pound largemouth bass taken from Harrison Bay and 6

Sale Creek. Numbers of lunker bass increased substantially from last year's survey. A total of 23 bass over four pounds were collected and eight of these were over five pounds. In 2002, nine bass over four pounds were collected and four of them were five pounds plus.

Length frequency histograms illustrated a bimodal distribution with the dominant size classes being the 8-9 inch and 12-14 inch groups (Figure 4).

A positive correlation of habitat type-to-black bass abundance was evident on Chickamauga Reservoir during the 2003 survey. Among the three areas sampled, the correlations at Harrison Bay and Skull Island were positive but Sale Creek showed some variability among habitat types (Table 13). Overall catch rates for the reservoir were 78, 66 and 40 at the good, fair and poor habitats, respectively (Table 14).

The RSD and PSD value of 17 and 61 fell within the desirable or preferred ranges of 10-25 and 40-70, respectively (Figures 5 and 6).

The values shown in Figure 7 are designated by inch groups which reflect the classical categories, i.e., 0-7 = substock, 8-11 = stock, 12-14 = quality, 15-19 = preferred, 20-24 =

memorable and 25+ = trophy. All categories fell within the desired range, which reflects excellent condition of black bass in all size groups of the population. Field observations of large numbers of prey fish indicate an abundance of forage for all size classes of black bass.

A total of 288 crappie (249 black and 39 white crappie) were also collected during the survey.

The crappies were collected predominantly from tree tops, stumps and other physical structures in shallow water.

7

Literature Cited Dycus, D. L. and D. L. Meinert. 1993. Reservoir Monitoring, Monitoring and Evaluation of Aquatic Resource Health and Use Suitability in Tennessee Valley Authority Reservoirs.

Tennessee Valley Authority, Water Resources, Chattanooga, Tennessee, TVA/WM-93/15.

Hickman, G. D. 2000. Sport Fish Index (SFI), A Method to Quantify Sport Fishing Quality.

Environmental Science & Policy 3 (2000) S117-S125.

Tennessee Department of Environment and Conservation. 2000. Draft NPDES Permit Number TN0026450.

Tennessee Valley Authority. 1996. A Supplemental 316(a) Demonstration for Alternative Thermal Discharge Limits for Sequoyah Nuclear Plant, Chickamauga Reservoir, Tennessee.

Tennessee Valley Authority, Engineering Laboratory, Norris, TN. WR96-1-45-145. 87 pp.

8

Table 1. Scoring Results for the Twelve Metrics and Overall Reservoir Fish Assemblage Index for Chickamauga Reservoir at the Sequoyah Downstream Sampling Station, 2003.

Forebay TRM 472.3 aTransition

-TRM 482.0 Downstream Station Metric Obs Score i.I Obs.. :

.Score A. Species richness and composition

1. Number of species
2. Number of centrachid species
3. Number of benthic invertivores
4. Number of intolerant species
5. Percent tolerant species
6. Percent dominance by one species
7. Number non-native species
8. Number of top carnivore species B. Trophic composition
9. Percent top carnivores
10. Percent omnivores C. Fish abundance and health
11. Average number per run L_
12. Percent anomalies 26 8

3 5

2 S

electrofishing gill netting electrofishing gill netting electrofishing gill netting electrofishing gill netting electrorishing gill netting electrofishing 55.6 27 29.9 21.4 1.0 0.5 10 9.5 49.5 11.2 35.2 32.1 1

5 1.5 1.5 1.5 1.5 2.5 2.5 1.5 1.5 2.5 0.5 0.5

25.

3

-6.5 5'

5. :

54.7

.1.5 4

26.4 1.5

  • 24.'8.

2.5, 19.6

'1.5 0.3.

2.5 0.7 2.5 11 5,

11.2 2.5 37.2 1.5 20.4. '

2.5 39.2 0.5

'45.7' 0'.5 14.8 1.5 0.3 i

2.5 0.71e 2.5 gill netting electrofishing gill netting 19.6 0.8 0.5 1.5 2.5 2.5 RFAI 43

,45 Good

: Good :

9

Table 2. Scoring Results for the Twelve Metrics and Overall Reservoir Fish Assemblage Index for Chickamauga Reservoir at the Upstream Sampling Station, 2003.

Metric I

A. Species richness and composition

1. Number of species
2. Number of centrachid species
3. Number of benthic invertivores
4. Number of intolerant species
5. Percent tolerant species
6. Percent dominance by one species
7. Number non-native species
8. Number of top carnivore species B. Trophic composition
9. Percent top carnivores
10. Percent omnivores electrofishing gill netting electrofishing gill netting electrofishing gill netting electrofishing gill netting electrofishing gill netting Transition i

TRM 490.5; l

Upstream Station..

Obs Score 29 3

8.

5 31 5.;,

5 67.0 0.5 29.7 1.5 31.2 1.5 28.1 0.5

- 1.1-2.5

-0.8 2.5, 10 5

11.8

'2.5, 31.3

.1.5

20.8 2.5 44.2 1.5 41.3.

0.5 24.9:.

2.5 1.0 2.5 6.4 0.5.

Inflow TRM 529.0 30 8

5 5

5 3

5 5

Obs Score 57.7 0

34.2 0.0 0.6 0

10 10.2 0

18.7 0

69.1 0

0.7 0

C. Fish abundance and health

11. Average number per run
12. Percent anomalies electrofishing gill netting electrofishing gill netting To Of RFAI g

42 48 I_'_:;

Good'*

Good 10

I---

I----

ri-V7--

[77-

[n-r,--

1 -

1I I ------

I'------ I

-- (- -

lI, --

I I

I Table 3. Recent (1993-2003) RFAI Scores Collected as Part of the Vital Signs Monitoring Program Upstream and Downstream of Sequoyah Nuclear Plant.

Station Reservoir Location 1993 1994 1995 1997 1999[.1993--

2000* 2001 2002*

2003 1993-2003 g

-1999.

Average eAverage Upstream Chickamauga TRM 49 40 46 39 45 :44 l 46 45 51 42 46 490.5 R-(Good).

(Good)

Sequoyah Chickamauga TRM 41

- 41 48 46 43 45 46 Transition 482.0

.(Good)

(Good)

Forebay Chickamauga TRM 44 44 47 39 45 L-.-.

45 48 46 43 46-.

472.3 (Good) I (Good)

  • The 2000, and 2002, sample years were not part of the VS monitoring program, however the same methodology was applied.

11

Table 4. Species Listing and Catch Per Unit Effort for the Embayment and Sequoyah Transects During the Fall Electrofishing and Gill Netting on Chickamauga Reservoir, 2003 (Electrofishing Effort = 300 Meters of Shoreline and Gill Netting Effort = Net-Nights).

Forebay TRM 472.3 Transition TRM 482.0 Electrofishing Electrofishing Gill Netting Electrofishing Electrofishing Gill Netting Catch Rate Catch Rate Catch Rate Catch Rate Catch Rate Catch Rate Common Name Per Per Hour Per Per Per Hour Per Run Net Night Run Net Night Spotted gar 0.27 1.43 0.20 1.08 Longnose gar 0.10 Skipjack herring 3.30 0.70 Gizzard shad 2.73 14.70 4.20 8.40 45.32 2.90 Threadfin shad 0.20 1.08 0.10 Common carp 0.33 1.79 0.13 0.72 0.10 Golden shiner 0.53 2.87 0.10 0.40 2.16 0.10 Emerald shiner 6.33 34.05 6.20 33.45 Spotfin shiner 0.13 0.72 1.33 7.19 Spotted sucker 0.20 1.08 0.60 0.27 1.44 0.50 Blue catfish 1.60 1.20 Channel catfish 1.00 0.40 2.16 1.50 Flathead catfish 0.33 1.79 0.20 0.13 0.72 0.30 White bass 0.10 Yellow bass 0.07 0.36 2.40 0.13 0.72 1.80 Warmouth 0.27 1.43 Redbreast 3.33 17.92 1.93 10.43 Green sunfish 0.27 1.43 Bluegill 9.60 51.61 0.70 11.33 61.15 0.40 Longear sunfish 0.40 2.15 1.93 10.43 Redear sunfish 3.67 19.71 1.00 6.40 34.53 1.60 Hybrid sunfish 0.07 0.36 Smallmouth 0.20 1.08 0.10 0.13 0.72 1.20 Spotted bass 1.27 6.81 2.50 2.80 15.11 0.80 Largemouth 0.93 5.02 0.20 1.47 7.91 0.20 White crappie 0.10 0.10 Black crappie 0.80 0.27 1.44 0.10 Yellow perch 0.10 Logperch 0.60 3.24 Sauger 0.20 Freshwater 0.27 1.43 0.50 0.33 1.80 1.00 Brook silverside 0.73 3.94 Total 32.13 172.76 19.6 45.71 246.76 14.8 Number 15 10 15 10 Number 482 196 686 148 Species 22 19 20 19 12

Table 5. Species Listing and Catch Per Unit Effort for the Transition and Inflow Transects During the Fall Electrofishing and Gill Netting on Chickamauga Reservoir, 2003 (Electrofishing Effort = 300 Meters of Shoreline and Gill Netting Effort = Net-Nights).

Transition TRM 490.5 l

Inflow TRM 529.0 Electrofishing Electrofishing Gill Netting Electrofishing Electrofishing Catch Rate Catch Rate Catch Rate Catch Rate Catch Rate Common Name Per Per Per Per Per Run Hour Net Night Run Hour Longnose gar 0.20 1.08 Lake sturgeon 0.10 Spotted gar 0.07 0.34 Skipjack herring 2.10 Gizzard shad 5.60 28.38 7.00 11.87 63.8 Threadfin shad 1.13 5.74 0.10 17.67 94.98 Common carp 0.4 2.03 0.40 2.15 Golden shiner 1.67 8.45 0.20 1.08 Emerald shiner 1.00 5.07 0.20 1.08 Spotfin shiner 1.27 6.42 0.73 3.94 Steelcolor shiner 0.27 1.43 Bluntnose minnow 0.80 4.05 0.13 0.72 Spotted sucker 0.40 2.03 0.30 0.27 1.43 Black redhorse 0.40 2.15 Golden redhorse 0.40 2.15 Blue catfish 2.60 Channel catfish 0.13 0.68 1.40 0.33 1.79 Flathead catfish 0.33 1.69 0.40 0.33 1.79 White bass 0.13 0.72 Yellow bass 3.30 1.13 6.09 Warmouth 0.93 4.73 0.07 0.36 Redbreast sunfish 3.87 19.59 0.47 2.51 Green sunfish 0.20 1.01 0.20 1.08 Bluegill 12.87 65.2 23.60 126.88 Longear sunfish 1.80 9.12 0.20 1.08 Redear sunfish 3.00 15.2 4.70 4.07 21.86 Hybrid sunfish 0.13 0.72 Smallmouth bass 0.80 4.05 0.67 3.58 Spotted bass 1.40 7.09 0.70 1.60 8.60 Largemouth bass 1.00 5.07 0.30 2.00 10.75 White crappie 0.10 0.07 0.36 Black crappie 1.27 6.42 0.80 0.87 4.66 Yellow perch 0.07 0.34 0.20 13

Table 5. (continued)

Transition TRM 490.5 Inflow TRM 529.0 Electrofishing Electrofishing Gill Netting Electrofishing Electrofishing Catch Rate Catch Rate Catch Rate Catch Rate Catch Rate Common Name Per Per Per Per Per Run Hour Net Night Run Hour Logperch 0.27 1.35 0.07 0.36 Sauger 0.10 Walleye 0.07 0.36 Freshwater drum 0.33 1.69 0.70 0.20 1.08 Brook silverside 0.67 3.38 0.13 0.72 Total 41.28 209.12 24.9 69.08 371.34 Number Samples 15 10 15 Number Collected 619 249 1036 Species Collected 25 17 32 14

Table 6. Individual Metric Ratings and the Overall Benthic Community Index Score for Upstream and Downstream Stations near Sequoyah Nuclear Plant, Chickamauga Reservoir, November 2003.

TRM 490.5 TRM 482 Upstream Downstream Metric Obs Rating Obs Rating

1. Average number of taxa 7.4 5

5.7 5

2. Proportion of samples with long-lived organisms 90%

5 60%

3

3. Average number of EPT taxa 0.7 3

0.3 1

4. Average proportion of oligochaete individuals 10.7%

5 9.4%

5

5. Average proportion of total abundance comprised by the 71.0%

5 79.8%

5 two most abundant taxa

6. Average density excluding chironomids and oligochaetes 341.7 3

580.0 5

Zero-samples - proportion of samples containing no 0

5 0

5 organisms Benthic Index Score 31 29 Good Good

  • Scored with transition criteria.

15

Table 7. Average Mean Density Per Square Meter of Benthic Taxa Collected at Upstream and Downstream Stations near Sequoyah Nuclear Plant, Chickamauga Reservoir, November 2003.

TRM Chickamauga Reservoir 490.5 Upstream Mean Occurrence Species Density per site Phylum Annelida Subclass Oligocheata Family Tubificidae 120 8

Branchiura sowerbyi 2

1 Limnodrilhs hoffnmeisteri 30 6

Class Hirudinea Rhynchobdellida Family Glossiphoniidae 5

1 Helobdella stagnalis 18 4

Phylum Insecta Order Ephemeroptera Family Ephemeridae Hexagenia limbata <10mm 17 6

Hexagenia limbata >10mm 32 8

Order Trichoptera Family Polycentropodidae Polycentropits sp.

2 1

Family Leptoceridae Oecetis sp.

2 1

Order Diptera Family Chironomidae Ablabesmyia annulata 8

3 Clhironomuts sp.

10 5

Phylum Mollusca Class Gastropoda Order Mesogastropoda Family Viviparidae Campeloma sp.

2 1

Vivipants Georgianus 33 4

Vivipanrs sp.

18 3

Class Bivalvia Veneroida Family Corbiculidae Corbiculafluminea <10mm 38 7

Corbiculaflurninea >10mm 93 8

16

Table 7. (continued)

TRM Chickamauga Reservoir 490.5 Upstream Mean Occurrence Species Density per site Family Sphaeriidae Musculidni transversunt 80 7

Number of samples 10 Sum 862 Number of taxa 15 Number of EPT taxa 3

Sum of area sampled 0.6 TRM Chickamauga Reservoir 482 Downstream Mean Occurrence Species Density per site Nematoda Turbellaria Tricladida Planariidae Dugesia tigrina 2

1 Phylum Annelida Subclass Oligocheata Family Lumbricidae 2

1 Family Tubificidae 42 5

Limnodrilhs lhoffineisteri 13 5

Class Hirudinea 2

1 Rhynchobdellida Family Glossiphoniidae 2

1 Helobdella stagnalis 20 5

Pharyngobdellida Family Erpobdellidae 7

1 Crustacea Amphipoda Crangonyctidae Crangonyx sp.

2 1

Phylum Insecta Order Ephemeroptera Family Ephemeridae 17

Table 7. (continued)

Chickamauga Reservoir TRM 482 Downstream Mean Occurrence Density per site 5

2 25 3

Order Family Order Family Phylum Class Family Order Family Class Family Family Species Hexagenia limbata <10mm Hexagenia limbata >10mm Trichoptera Polycentropodidae Cyrnellusfraternis Diptera Chironomidae Ablabesmyia annidata Axanrs sp.

Cihirononuts sp.

Coelotanyputs sp.

Mollusca Gastropoda Lymnophila Physidae Pihysella sp.

Mesogastropoda Viviparidae Vivipants Georgianus Bivalvia Veneroida Corbiculidae Corbiculafluminea <10mm Corbiculaflurminea >10mm Sphaeriidae Eupera cubensis M'usculium transversitmn 8

3 10 2

7 127 4

1 3

8 2

1 62 3

195 98 9

9

-3 200 1

10 Number of samples Sum Number of taxa Number of EPT taxa Sum of area sampled 10 833 18 2

0.6 18

F l -,-

l

[--

1-F --

F-1---,

[ w4 I

I I -",

I -

I -

I I ----

r --- ' I. 1- --

I '

Table 8. Recent (1994-2003) Benthic Index Scores Collected as Part of the Vital Signs Monitoring Program at Chickamauga Reservoir Transition (TRM 490.5 and TRM 482) and Forebay Zone (TRM 472.3) Stations.

Year Site Reservoir Location 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 Average Upstream Chickamauga TRM 490.5 33 29 31 31 23 25 23 31 28.3 Downstream Chickamauga TRM 482 23 31 27 29 28.0 Downstream Chickamauga TRM 472.3 31 27 29 25 27 27 23 27 27.0 Table 9. Sport Fishing Index Results for Chickamauga Reservoir, 2003 Year Species 1997 1998 1999 2000 2001 2002 2003 1997-2003 Average SFI Score Black bass 35 41 25 35 31 34 34 34 Smallmouth bass 20 20 24 22 40 32 32 28 Spotted bass 20 37 24 40 26 32 32 30 Largemouth bass 34 37 34 32 28 36 36 34 Bluegill 30 32 33 32 32 31 32 Channel catfish 32 29 30 25 33 35 Crappie 32 31 31 32 38 42 35 Sauger 27 36 32 39 30 31 27 32 Striped bass 35 30 30 40 34 31 33 White bass 31 30 30 30 40 32 19

Table 10. Sport Fishing Index Population Quantity and Creel Quantity and Quality Metrics and Scoring Criteria.

Metrics Scores 5

10 15 Black bass Population (quantity)

TVA electrofishing catch/hour

< 15 15-31

> 31 State electrofishing (catch/hour)

< 62 62-124

> 124 Creel (quantity)'

Anglers (catch/hour)

< 0.3 0.3-0.6

> 0.6 BAIT and BITE data

< 1.1 1.1-2.3

> 2.3 Creel (quality)

Pressure (hours/acre)

< 8 8-16

> 16 Largemouth bass Population (quantity)b TVA electrofishing catch/hour

< 13 13-25

> 25 State electrofishing (catch/hour)

< 53 53-106

> 106 Creel (quantity)

Anglers (catch/hour)

< 0.29 0.29-0.58

> 0.58 Creel (quality)

Pressure (hours/acre)

< 8 8-16

> 16 Smallmouth bass Population (quantity)

TVA electrofishing catch/hour

< 4 4-8

> 8 State electrofishing (catch/hour)

< 8 8-15

> 15 L

Creel (quantity)

Anglers (catch/hour)

< 0.1 0.1-0.3

> 0.3 Creel (quality)

Pressure (hours/acre)

< 8 8-16

> 16 Spotted bass Population (quantity)

TVA electrofishing catch/hour

< 5 5-11

> 11 State electrofishing (catch/hour)

< 14 14-27

> 27 L

Creel (quantity)

Anglers (catch/hour)

< 0.07 0.07-0.13

> 0.13 Creel (quality)

Pressure (hours/acre)

< 8 8-16

> 16 20

Table 10. (continued)

Metrics Scores 5

10 15 Sauger Population (quantity)

Experimental gill net (catch/net night)

< 9 9-17

> 17 Creel (quantity)

Anglers (catch/hour)

< 0.5 0.5-1

> 1 Creel (quality)

Pressure (hours/acre)

< 5 5-10

> 10 Channel catfish Population (quantity)

Experimental gill net (catch/net night)

< 2 2-4

> 4 Creel (quantity)

Anglers (catch/hour)

< 0.3 0.3-0.7

> 0.7 Creel (quality)

Pressure (hours/acre)

< 9 9-19

> 19 aEach worth 2.5, 5.0, and 7.5 points if both data sets are available.

bTVA electrofishing only used when state agency electrofishing data is unavailable.

21

Table 11. Sport Fishing Index Population Quality Metrics and Scoring Criteria.

Scores 5

10 15 Metrics Population (quality) 1 2

3 PSD

< 20 or > 80 20-39 or 61-80 40-60 RSDP (preferred) 0 or> 60 1-9 or 41-60 10-40 RSDM (memorable) 0 or> 25 1-4 or 11-25 5-10 RSDT (trophy) 0

< 1 2 1 Wr (Stock-preferred size fish)

< 90

> 110 90-110 Table 12. Electrofishing Catch Rate, Mean Weight, Percent Harvestable, Numbers of Black Bass Greater than Five Pounds, Numbers of Black Bass Greater than Four Pounds and Largest Black Bass Collected, Chickamauga Reservoir Black Bass Surveys, 1995-2003.

EF Catch Mean Largest Rate Weight Bass >4 Bass >5 bass Year (no./hr.)

(lbs.)

Harvestable lbs.

lbs.

lbs.)

2003 62.0 1.3 65.8 23 8

6.4 2002 57.4 1.1 59.4 9

4 6.6 2001 34.5 0.8 45.2 0

0 2.8 2000 34.4 1

51.2 3

0 4.8 1999 10.6 1.3 60.7 3

1 6.1 1998 37.2 1.1 44.5 9

2 6.6 1997 40.2 1

70.1 8

4 8.7 1996 51 1.2 42.6 13 9

7.9 1995 _

62 1.2 61.8 28 12 8.3 22

Table 13. Black Bass Catch Per Hour Compared to Habitat Types by Location.

Habitat Desi2nation Reservoir and Site Good Fair Poor Chickamauga Harrison Bay 99(4) 61(4) 31(4)

Sale Creek 67(4) 76(4) 36(4)

Skull Island 69(4) 63(5) 58(3)

Watts Bar Blue Springs 69(3) 47(4) 46(5)

Caney Creek 78(3) 61(5) 49(4)

Kingston 59(4) 43(4) 43(4)

Watts Bar Dam 107(3) 43(5) 62(4)

I I.

Catch per hour = number of fish collected per hour

( ) = number of transects sampled at each location Table 14. Black Bass Catch Per Hour Compared to Habitat Types by Reservoir.

l___

lHABITAT DESIGNATION Reservoir Good Fair Poor I

Chickamauga 78 66 40 l

l Watts Bar 77 49 l

50 l Wheeler 57 54 l

56 l

Catch per hour = number of fish collected per hour 23

Quantity Parameters Quality Parameters lAnglerSuccess Sampling CPUE AnglingPressure Species Population I

I Ii~

Figure 1. Parameters used to calculate the Sport Fishing Index (SFI).

24

I I

I I

I I

I I

I I

I I

I I

Chickamauga RFAI Scores 1993-2003 60 50 40 00

-3 0

20 10 0

1993 1994 1995 1996 1997 1998 Year 1999 2000 2001 2002 2003 Figure 2. RFAI scores from sample years between 1993 and 2003.

25 Cad

l kI I

I I

i I

a I

I I

I I

I e

1 I

I I

Chickamauga SFI Scores 1997-2003 60 50 40 4)00 M

n 30

  • Black bass
  • Largemouth bass o Smallmouth bass O Spotted bass
  • Crappie
  • Sauger
  • Striped bass
  • Bluegill
  • Channel catfish
  • White bass 20 10 0

1997 1998 1999 2000 2001 2002 2003 Year Figure 3. Sport Fishing Index results for Chickamauga Reservoir between 1997 and 2003.

26

LENGTH FREQUENCY ALL SITES CHICKAMAUGA 2003 160 160 140 120 100 80 60 40 20 0

3 5

7 9

11 13 15 17 19 21 23 25 INCH GROUP Figure 4. Chickamauga Reservoir length frequency histogram, (all sites) spring 2003.

27

RSD VALUES MAINSTEM RESERVOIRS SPRING 2003 50 45.

40 ma, 35 co 30 co 25 20 15 10 5.

0 43 28

.17 A 21

,C)

CD CD z

0 co0

-c m

SD Pc 3

3 0

=

5 ID (0

Reservoir Figure 5. Relative stock density values for Tennessee River Reservoirs.

28

PSD VALUES MAINSTEM RESERVOIRS SPRING 2003 100 90 80 a) 70 co 60 C

50 C) b-40 30 ffi 30 20 10 0

o n C>

A X

rm1 co (0

Reservoir Figure 6. Proportional stock density values for Tennessee River Reservoirs.

29

CHICKAMAUGA Wr ALL SITES 2003 Is Percent -

  1. of Fishl 100 80 C) a)0~

60 40 20 45 40 35.0 30 L 25 ° 20 W 15 E 10 z 5

0 0

0-7 8-11 12-14 15-19 20-24 25 +

Relative Stock Size by Inch Group Figure 7. Chickamauga Reservoir mean relative weights (Wr) for largemouth bass broken out by RSD category and fish numbers.

30