ML041590049

From kanterella
Jump to navigation Jump to search

Ltr. Donald C. Cook Unit 1, - Summary of the NRC Staff'S Review of Steam Generator Tube Inspection for the Fall 2003 Outage
ML041590049
Person / Time
Site: Cook American Electric Power icon.png
Issue date: 06/15/2004
From: John Lamb
NRC/NRR/DLPM/LPD3
To: Nazar M
American Electric Power Co, Indiana Michigan Power Co
Lamb J, NRR/DLPM, 415-1446
References
TAC MC2992
Download: ML041590049 (3)


Text

June 15, 2004 Mr. Mano K. Nazar American Electric Power Senior Vice President and Chief Nuclear Officer Indiana Michigan Power Company Nuclear Generation Group 500 Circle Drive Buchanan, MI 49107

SUBJECT:

DONALD C. COOK NUCLEAR PLANT, UNIT 1 -

SUMMARY

OF THE NUCLEAR REGULATORY COMMISSION STAFFS REVIEW OF STEAM GENERATOR TUBE INSPECTION

SUMMARY

REPORT FOR THE FALL 2003 OUTAGE (TAC NO. MC2992)

Dear Mr. Nazar:

By letters dated November 14, 2003, and March 1, 2004, Indiana Michigan Power Company (I&M, the licensee) submitted the steam generator tube inspection summary reports for the fall 2003 outage at Donald C. Cook Nuclear Plant, Unit 1 in accordance with the plants Technical Specifications (TS).

The Nuclear Regulatory Commission (NRC) staff has completed its review of these reports and concludes that the licensee provided the information required by its TS and that no additional follow-up is required at this time. The NRC staff did not identify any issues.

This completes our work under TAC No. MC2992. If you have any questions, please contact me at (301) 415-1446.

Sincerely,

/RA/

John G. Lamb, Project Manager, Section 1 Project Directorate III Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-315 cc: See next page

ML041590049 *See memo OFFICE PDIII-1/PM PDIII-1/LA EMCB/SC PDIII-1/SC NAME JLamb THarris ALund* LRaghavan DATE 06/08/04 06/08/04 05/25/04 06/09/04 Donald C. Cook Nuclear Plant, Units 1 and 2 cc:

Regional Administrator, Region III Michigan Department of Environmental U.S. Nuclear Regulatory Commission Quality 801 Warrenville Road Waste and Hazardous Materials Div.

Lisle, IL 60532-4351 Hazardous Waste & Radiological Protection Section Attorney General Nuclear Facilities Unit Department of Attorney General Constitution Hall, Lower-Level North 525 West Ottawa Street 525 West Allegan Street Lansing, MI 48913 P. O. Box 30241 Lansing, MI 48909-7741 Township Supervisor Lake Township Hall David A. Lochbaum P.O. Box 818 Nuclear Safety Engineer Bridgman, MI 49106 Union of Concerned Scientists 1707 H Street NW, Suite 600 U.S. Nuclear Regulatory Commission Washington, DC 20036 Resident Inspectors Office 7700 Red Arrow Highway Michael J. Finissi, Plant Manager Stevensville, MI 49127 Indiana Michigan Power Company Nuclear Generation Group David W. Jenkins, Esquire One Cook Place Indiana Michigan Power Company Bridgman, MI 49106 One Cook Place Bridgman, MI 49106 Mr. Joseph N. Jensen, Site Vice President Indiana Michigan Power Company Mayor, City of Bridgman Nuclear Generation Group P.O. Box 366 One Cook Place Bridgman, MI 49106 Bridgman, MI 49106 Special Assistant to the Governor Room 1 - State Capitol Lansing, MI 48909 Mr. John A. Zwolinski Director, Design Engineering and Regulatory Affairs Indiana Michigan Power Company Nuclear Generation Group 500 Circle Drive Buchanan, MI 49107