Special Report on Steam Generator Tube Plugging
ML041450308
Person / Time
Site: South Texas STP Nuclear Operating Company icon.png
Issue date: 05/04/2004
From: Crenshaw J
South Texas
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NOC-AE-04001715
Download: ML041450308 (2)


Text

Nuclear Operating Company South Tns ftd EkHdo c GenawIn Stiation PiO. &o 289 idsWrth,s 77483 May 4, 2004 NOC-AE-04001715 U. S. Nuclear Regulatory Commission Attention: Document Control Desk One White Flint North 11555 Rockville Pike Rockville, MD 20852 South Texas Project Unit 2 Docket No. STN 50-499 Special Report on Steam Generator Tube Plugging In accordance with Technical Specifications 4.4.5.5.a, STP Nuclear Operating Company submits the following information on the number of steam generator tubes plugged in each Unit 2 steam generator. The first inservice inspection of the replacement steam generators was conducted recently during refueling outage 2RE10.

Steam Tubes Plugged Tubes Plugged Cumulative Generator Before Installation During 2RE10 Total 2A 1

0 1

2B 2

0 2

2C 3

0 3

2D 0

0 0

Total Unit 2 6

If there are questions regarding this report, please contact Mr. M. J. Berg at (361) 972-7030 or me at (361) 972-7074.

J. W. Crenshaw Manager, Plant Engineering jtc Ao STI: 31735142

NOC-AE-04001715 Attachment Page 2 of 2 cc:

(paper copy)

(electronic copy)

Bruce S. Mallett Regional Administrator, Region IV U. S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 400 Arlington, Texas 76011-8064 U. S. Nuclear Regulatory Commission Attention: Document Control Desk One White Flint North 11555 Rockville Pike Rockville, MD 20852 Richard A. Ratliff Bureau of Radiation Control Texas Department of Health 1100 West 49th Street Austin, TX 78756-3189 Jeffrey Cruz U. S. Nuclear Regulatory Commission P. 0. Box 289, Mail Code: MN1 16 Wadsworth, TX 77483 A. H. Gutterman, Esquire Morgan, Lewis & Bockius LLP L. D. Blaylock City Public Service Michael K. Webb U. S. Nuclear Regulatory Commission R. L. Balcom Texas Genco, LP A. Ramirez City of Austin C. A. Johnson AEP Texas Central Company Jon C. Wood Matthews & Branscomb C. M. Canady City of Austin Electric Utility Department 721 Barton Springs Road Austin, TX 78704