E-mail Dated 04/25/04 to T. Alexion ANO 1 - Daily Status of Alloy 600/RV Head Inspections for 1R18
ML041410164
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 04/25/2004
From: Sharon Bennett
Entergy Operations
To: Alexion T, David Bice, Burford F, Campbell B, Clark J, Compton L, Daiber B, Davant G, Rick Deese, Eaton W, Edgell D, Ehren T, Eubanks C, Forbes J, Forrest F, Gobell J, Gordon R, Houghtaling J, James D, James W, Kowalewski J, Robert Lewis, Means B, Mitchell T, Panther K, Parks G, Payne G, Sims W, James Smith, Swain R
NRC/NRR/DLPM/LPD4
Alexion T W, NRR/DLPM, 415-1326
References
Download: ML041410164 (4)


Text

I Tho M-as-Alexio'n - Daily-Statius -of Alloy 600/RV Head Inspections for 1 R1 8 Page 1 Dl

-i,

.N I Thomas Alexion - Daily Status of Alloy 600/RV Head !rpecions for 1 Ri 8 Paae 1 II From:

"BENNETT, STEVE A' <SBENNE2@entergy.com>

To:

Tom Alexion <twa~nrc.gov>, "Jeff Clark (ac~nrc.gov)" <jacQnrc.gov>, "SWAIN, RONALD VANCE" <RSWAIN1 @entergy.com>, "BICE, DAVID B" <DBICE@entergy.com>, "BURFORD, FRANCIS G" <FBURFOR@entergy.com>, "CAMPBELL, BILL - NUCLEAR" <WCAMPB3@entergy.com>,

"COMPTON, LESLIE' <LCOMPTO@entergy.com>, "DAIBER, BRYAN J" <BDAIBER@entergy.com>,

"DAVANT, GUY H" <GDAVANT@entergy.com>, "DEESE, RICHARD Wm <rdees90@entergy.com>,

"EATON, WILLIAM A" <WEATON~entergy.com>, "EDGELL, DOUGLAS Wm

<DEDGELL@entergy.com>, "EHREN, TERRY G" <TEHREN~entergy.com>, "EUBANKS, CLIFFORD'

<CEUBANK entergy.com>, "FORBES, JEFFREY" <JFORBE1 @entergy.com>, "FORREST, FREDDIE"

<FFORRES~entergy.com>, "GOBELL, JAMIE N" <JGOBELL~entergy.com>, "GORDON, ROBERT A"

<RGORDON entergy.com>, "HOUGHTALING, JOHN B" <JHOUGHT entergy.com>, "JAMES, DALE E" <DJAMES © entergy.com>, "JAMES, WILLIAM" <WJAM ES1 @ entergy.com>, 'KOWALEWSKI, JOSEPH A" <JKOWALE@entergy.com>, "LEWIS, RAYMOND S" <RLEWIS1 @entergy.com>, "MEANS, BRACY E" <BMEANS@entergy.com>, "MITCHELL, TIMOTHY G" <TMITCH1 @entergy.com>,

  • PANTHER, KENNETH C" <KPANTHE@entergy.com>, "PARKS, GLENN A" <GPARKS@entergy.com>,

"PAYNE, GARY - WF3" <GPAYNE~entergy.com>, "SIMS, WILLIAM D" <WSIMS@entergy.com>,

"SMITH, JAMES A" <JSMITH~entergy.com>

Date:

4/25/04 9:07AM

Subject:

Daily Status of Alloy 600/RV Head Inspections for 1 R18 Attached is the April 25, 2004 status of the Alloy 600/RV Head Inspections for 1R18 Steve Bennett NSA - Licensing 479-858-4626 Pager: 479-890-3323

I C:\\W1ND0WS\\TEMP\\GW100001.TMP

_Page 1 1 I C:\\WINDOWS\\TEMP\\GWIOOOO1.TMP Paae 1 t Mail Envelope Properties (408BB815.8F7: 19: 59639)

Subject:

Daily Status of Alloy 600/RV Head Inspections for lR18 Creation Date:

4/25/04 9:03AM From:

"BENNETT, STEVE A" <SBENNE2@entergy.com>

Created By:

SBENNE2@entergy.com Recipients nrc.gov owf4_po.0WFN_DO TWA (Thomas Alexion) nrc.gov ARL_PO.ARL_DO JAC (Jeffrey Clark) entergy.com JSMITH (SMITH, JAMES A)

WSIMS (SIMS, WILLIAM D)

GPAYNE (PAYNE, GARY - WF3)

GPARKS (PARKS, GLENN A)

KPANTHE (PANTHER, KENNETH C)

TMlTCHI (MITCHELL, TIMOTHY G)

BMEANS (MEANS, BRACY E)

RLEWIS1 (LEWIS, RAYMOND S)

JKOWALE (KOWALEWSKI, JOSEPH A)

WJAMES 1 (JAMES, WILLIAM)

DJAMES (JAMES, DALE E)

JHOUGHT (HOUGHTALING, JOHN B)

RGORDON (GORDON, ROBERT A)

JGOBELL (GOBELL, JAMIE N)

FFORRES (FORREST, FREDDIE)

JFORBE1 (FORBES, JEFFREY)

CEUBANK (EUBANKS, CLIFFORD)

TEHREN (EHREN, TERRY G)

DEDGELL (EDGELL, DOUGLAS W)

WEATON (EATON, WILLIAM A) rdees90 (DEESE, RICHARD W)

GDAVANT (DAVANT, GUY H)

BDAIBER (DAIBER, BRYAN J)

LCOMPTO (COMPTON, LESLIE)

WCAMPB3 (CAMPBELL, BILL - NUCLEAR)

FBURFOR (BURFORD, FRANCIS G)

DBICE (BICE, DAVID B)

C:\\WINDOWS\\TEMP\\GWIOOOO1.TMP Page 2 ii

'CA\\WND0WS\\TEMP\\GW}00001.TMP Page 2 4 RSWAIN1 (SWAIN, RONALD VANCE)

Post Office owf4_po.OWFNDO ARLPO.ARLDO Files Size MESSAGE 153 Part.001 787 IR18 RVH Inspection Results 4-25.doc Mime.822 64437 Route nrc.gov nrc.gov entergy.com Date & Time 04/25/04 09:03AM 44032 Options Expiration Date:

Priority:

Reply Requested:

Return Notification:

Concealed

Subject:

Security:

None Standard No None No Standard

April 25, 2004 - 8:00 AM 1R18 Alloy 600 Status Inspection Inspection Method Extent of Inspection 1 R1 8 Status/ Findings BMV of RV BMV exam inside Service 100% of the RPV head surface (including 3600 69 of 69 CRDM nozzles visually inspected on 4/24/04 Head Structure around each head penetration).

(OP 2311.009)

CR-ANO-1 -2004-written to document boric acid staining from 1 R17 RadCal seal leak (9 nozzles classified as UnSat)

No leaking nozzles identified CRDM/

UT of 60 CRDM nozzles UT of the RPV nozzle from 2" above the highest Scheduled to begin UT exams Monday (4/26/04).

RADCAL (no known defects) point of the root of the J-weld to the blind zone.

Nozzles UT of six FTI repaired UT the weld and at least 1-inch above the weld in CRDM nozzles (Nozzles the nozzle base material.

3,6,15,17,33,&56)

UTIWS of two W repaired UT of the RPV nozzle from 2" above the highest CRDM nozzles (Nozzles point of the root of the J-weld to the blind zone 54 & 68) and wetted surface exam of weld overlay.

UT of RADCAL Nozzle UT of the RPV nozzle from 2" above the highest (Nozzle 1) point of the root of the J-weld to the blind zone.

UT of nozzle Annulus Interrogate interference fit in all 69 nozzle annuli

[Leak Path Assessment]

above J-weld for leakage path ICI Nozzles Visual Inspection of 52 Inspect 100% of the circumference of each BMIs initially inspected on night shift 4/22/04 BMI nozzles penetration as it enters the RPV lower head.

CR-ANO-1-2004-827 written due to peacekeeping (OP 2311.009) concerns on nozzle inspections No leakingnozzles identified to date CR-ANO-1-2004-0735 written on rust/staining RCS Visually Inspect RCS for Visually inspect above the RPV head for potential No leaking A600 nozzles identified (ongoing)

Walkdowns RCS leaks boric acid leaks from pressure-retaining 5 of 9 pressurizer nozzles inspected components as well as other A600 RCS small 7 hot leg nozzles inspected bore locations. (OP 2311.009)

.4 CFT nozzles inspected I

I F

oze npce