D.C. Cook, Ltr. Units 1 & 2 Withdraw Amendment Request to Use Yield Strength Determined from Measured Material Properties for Reinforcing Bar in Structural Calculations for Control Rod Drive Missile Shield
ML041310461
Person / Time
Site: Cook  
Issue date: 05/18/2004
From: John Lamb
NRC/NRR/DLPM/LPD3
To: Nazar M
Indiana Michigan Power Co
Lamb J, NRR/DLPM, 415-1446
References
FOIA/PA-2005-0075, TAC MC1391, TAC MC1392
Download: ML041310461 (3)


Text

May 18, 2004 Mr. Mano K. Nazar American Electric Power Senior Vice President and Chief Nuclear Officer Indiana Michigan Power Company Nuclear Generation Group 500 Circle Drive Buchanan, MI 49107

SUBJECT:

DONALD C. COOK NUCLEAR PLANT, UNITS 1 AND 2 - WITHDRAWAL OF AN AMENDMENT REQUEST TO USE YIELD STRENGTH DETERMINED FROM MEASURED MATERIAL PROPERTIES FOR REINFORCING BAR IN STRUCTURAL CALCULATIONS FOR CONTROL ROD DRIVE MISSILE SHIELD (TAC NOS. MC1391 AND MC1392)

Dear Mr. Nazar:

By letter dated November 12, 2003 (ADAMS Accession No. ML033370903), you applied for an amendment to the Donald C. Cook Nuclear Plant (CNP), Units 1 and 2, Operating License Nos.

DPR-58 and DPR-74. The proposed change would have changed the facility licensing basis as described in the CNP Updated Final Safety Analysis Report. The change would have allowed the use of reinforcing bar (rebar) yield strength based on measured material properties as documented in certified material test reports (CMTRs) in structural calculations for the control rod drive missile shield.

In a letter dated March 21, 2003 (ADAMS Accession No. ML030770011), the Nuclear Regulatory Commission (NRC) staff stated that it does not, in principle, accept the use of material CMTR limits (e.g., yield strength) in lieu of normal specified code properties. Your submittal dated November 12, 2003, did not provide the necessary data to support your position. Subsequently, by letter dated March 2, 2004 (ADAMS Accession No. ML040690680),

you withdrew the amendment request.

The purpose of this letter is to advise that the above cited application is being treated as withdrawn. Notice of Consideration of Issuance of the proposed amendment had not been published in the Federal Register.

Sincerely,

/RA/

John G. Lamb, Project Manager, Section 1 Project Directorate III Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-315 and 50-316 cc: See next page

ML033370903), you applied for an amendment to the Donald C. Cook Nuclear Plant (CNP), Units 1 and 2, Operating License Nos. DPR-58 and DPR-74. The proposed change would have changed the facility licensing basis as described in the CNP Updated Final Safety Analysis Report. The change would have allowed the use of reinforcing bar (rebar) yield strength based on measured material properties as documented in certified material test reports (CMTRs) in structural calculations for the control rod drive missile shield.

In a letter dated March 21, 2003 (ADAMS Accession No. ML030770011), the Nuclear Regulatory Commission (NRC) staff stated that it does not, in principle, accept the use of material CMTR limits (e.g., yield strength) in lieu of normal specified code properties. Your submittal dated November 12, 2003, did not provide the necessary data to support your position. Subsequently, by letter dated March 2, 2004 (ADAMS Accession No. ML040690680),

you withdrew the amendment request.

The purpose of this letter is to advise that the above cited application is being treated as withdrawn. Notice of Consideration of Issuance of the proposed amendment had not been published in the Federal Register.

Sincerely,

/RA/

John G. Lamb, Project Manager, Section 1 Project Directorate III Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-315 and 50-316 cc: See next page DISTRIBUTION:

PUBLIC RidsNrrPMJLamb RidsNrrDlpmlpdiii (W. Ruland)

RidsOgcRp RidsAcrsAcnwMailCenter RidsNrrDlpmlpdiii1 (L. Raghavan)

RidsRgn3MailCenter (G. Grant)

THarris PDIII-1 r/f ADAMS Accession No. ML041310461 OFFICE PDIII-1/PM PDIII-1/LA PDIII-1/SC NAME JLamb THarris LRaghavan DATE 5/14/2004 5/14/2004 5/18/2004

Donald C. Cook Nuclear Plant, Units 1 and 2 cc:

Regional Administrator, Region III U.S. Nuclear Regulatory Commission 801 Warrenville Road Lisle, IL 60532-4351 Attorney General Department of Attorney General 525 West Ottawa Street Lansing, MI 48913 Township Supervisor Lake Township Hall P.O. Box 818 Bridgman, MI 49106 U.S. Nuclear Regulatory Commission Resident Inspectors Office 7700 Red Arrow Highway Stevensville, MI 49127 David W. Jenkins, Esquire Indiana Michigan Power Company One Cook Place Bridgman, MI 49106 Mayor, City of Bridgman P.O. Box 366 Bridgman, MI 49106 Special Assistant to the Governor Room 1 - State Capitol Lansing, MI 48909 Mr. John A. Zwolinski Director, Design Engineering and Regulatory Affairs Indiana Michigan Power Company Nuclear Generation Group 500 Circle Drive Buchanan, MI 49107 Michigan Department of Environmental Quality Waste and Hazardous Materials Div.

Hazardous Waste & Radiological Protection Section Nuclear Facilities Unit Constitution Hall, Lower-Level North 525 West Allegan Street P. O. Box 30241 Lansing, MI 48909-7741 David A. Lochbaum Nuclear Safety Engineer Union of Concerned Scientists 1707 H Street NW, Suite 600 Washington, DC 20036 Michael J. Finissi, Plant Manager Indiana Michigan Power Company Nuclear Generation Group One Cook Place Bridgman, MI 49106 Mr. Joseph N. Jensen, Site Vice President Indiana Michigan Power Company Nuclear Generation Group One Cook Place Bridgman, MI 49106