2003 Annual Environmental Operating Report, Non-Radiological
ML041250201
Person / Time
Site: Beaver Valley
Issue date: 12/31/2003
From:
FirstEnergy Nuclear Operating Co
To:
Office of Nuclear Reactor Regulation
References
Download: ML041250201 (88)


Text

-

E FIRSTENERGY NUCLEAR OPERATING COMPANY BEAVER VALLEY POWER STATION 2003 ANNUAL ENVIRONMENTAL OPERATING REPORT NON-RADIOLOGICAL UNITS NO. 1 AND 2 LICENSES DPR-66 AND NPF-73 96X40) :

r

TABLE OF CONTENTS Page 1.0 EXECUTIVE S UMIMARYY.........................................................................................

1.1 INRODUCTION........

1.2

SUMMARY

& CONCLUSIONS..........................................................................

1.3

-ANALYSIS OF SIGNIFICANT ENVIRONMENTAL CHANGE.......................

1.4 AOUATIC MONITORING PROGRAM EXECUTIVE

SUMMARY

2.0 ENVIRONMENTAL PROTECTION PLAN NON-COMPLIANCES.......................

3.0 CHANGES INVOLVING UNREVIEWED ENVIRONMENTAL QUESTION.

4.0 NONROUTINE ENVIRONMENTAL REPORTS......................................................

--5.0 AQUATIC MONITORING PROGRAM.......................................................................

5.1 INTRODUCTION

5.1.1 Objectives of the 5.1.2 Scope of Services................. ; ; :

5.1.3 Benthic Macroinvertebrate Monitoring......................................................

5.1.4 Fish Monitorng.....

- - 5..4

- ish Moitorig.....................................................................................

5.1.5 Larval Cajes/Zebra Mussel Sciaper/Bridal Veil Samplers Pump/Biobox Sampling............................................................................

5.1.6 Corbicula/Zebra Mussel Density DeterinationsD.

5.1.7 Monthly Activity Reports.

5.1.8 Site Description.

  • 5.2 AQUATIC MONITORING PROGRAM AND RESULTS.

5.2.1 Benthic'Macroinvertebrate Monitoring Program.....................................

5.2.1.1 Objectives....................................................................................

5.2.1.2 Methods.......................................................................................

5.2.1.3 Habitats........................................................................................

5.2.1.4 Results.......

5.2.1.5 Community Structure and Spatial Distribution...........................

5.2.1.6 Comparison of Control and Non-Control Stations......................

5.2.1.7 Seasonal Comparison..................................................................

5.2.1.8 Discussion...................................................................................

5.3 FISH.......................................................................................................................

5.3.1 Objectives.

5.3.2 Methods......................................................................................................

5.3.3 Results........................................................................................................

5.3.4 Comparison of Control and Non-Control Stations.....................................

5.3.5 Discussion.............

5.4 CORBICULA MONITORING PROGRAM..........................................................

5.4.1 Introduction................................................................................................

5.4.2 Monitoring..................................................................................................

5.4.2.1 Objectives....................................................................................

5.4.2.2 Methods.......................................................................................

2003 Annual Environmental Report FENOC (BVPS) i

I I TABLE OF CONTENTS Page 5.4.2.3 Results.........................................................................................

5.4.2.4 Discussion............................................

5.4.2.5 Corbicula Juvenile Study........................ ;

(1)

Objectives...........................................................................

(2)

M ethods..............................................................................

(3)

Results................................................................................

(4)

Discussion..........................................................................

5.5 ZEBRA MUSSEL MONITORING PROGRAM...................................................

5.5.1 Introduction................................................................................................

5.5.2 M onitoring..................................................................................................

5.5.2.1 Objectives....................................................................................

5.5.2.2 M ethods.......................................................................................

5.5.2.2.1 Intake Structure and Barge Slip..................................

5.5.2.2.2 Cooling Towers...........................................................

5.5.2.2.3 Emergency Outfall......................................................

5.5.2.2.4 Splash Pool.................................................................

5.5.3 Results.......................................................................................................

5.5.4 Discussion..................................................................................................

5.5.5 Zebra Mussel and Corbicula Control Activities Discussion......................

5.6 REFERENCES

2003 Annual Enviromnental Report FENOC (BVPS) ii

I aLIST-OF TABLES 5.1 Beaver Valley Power Station (BVPS) Sampling Dates For 2003 5.2 Systematic List of Macroinvertebrates Collected From 1973 through 2003 in the Ohio River Near BVPS (6 sheets) 5.3.1 Benthic Macroinvertebrates Counts for Triplicate Samples Taken at Each Sample Station by Sample For May 2003 5.3.2 Benthic Macroinvertebrates Counts for Triplicate Samples Taken at Each Sample Station by Sample For September 2003 5.4 Mean Number of Macroinvertebrates (Number/m2) and Percent Composition of Oligochaeta, Chironomidae, Mollusca and Other Organisms, 2003 - BVPS 5.5.

Mean Number of Macroinvertebrates (Number/r 2) and Percent Composition of Oligochaeta, Chirononidae, Mollusca and Other Organisms for the Control Station (1) and the Average for Non-control Stations (2B1, 2B2, and 2B3), 2003 BVPS 5.6 Shannon-Weiner. Diversity,- Evenness and Richness Indices for Benthic Macroinvertebrates Collected in the Ohio River, 2003 5.7 Benthic Macroinvertebrate Densities (Number/m2 ) for Station 1 (Control) and Station 2B (Non-Control) During Preoperational and Operational Years through 2003 BVPS (3 sheets) 5.8 Scientific and Common Name of Fish Collected in the New Cumberland Pool of the Ohio River, 1970 Through 2003, BVPS (3 sheets) 5.9 Comparison of Control vs. Non-Control Electrofishing Catches, During the BVPS 2003 Fisheries Survey 5.10 Comparison of Control vs. Non-Control Seine Catches, During the BVPS 2003 Fisheries Survey 5.11 Fish Species Collected During the May 2003 Sampling of the Ohio River in the Vicinity of BVPS 5.12 Fish Species Collected During the July 2003 Sampling of the Ohio River in the Vicinity of BVPS 5.13 Fish Species Collected During the September 2003 Sampling of the Ohio River in the Vicinity of BVPS 5.14 Fish Species Collected During the November 2003 Sampling of the Ohio River in 2003 Annual Environmental Report iii FENOC (BVPS)

I I LIST OF TABLES the Vicinity of BVPS 5.15 Estimated Number of Fish Observed During Electrofishing Operations 5.16 Catch Per Unit of Effort (CPUE as Fish/Electrofishing Minute) by Season During the BVPS 2001 Fisheries Survey (2 sheets) 5.17 Catch Per Unit of Effort (CPUE as Fish/Electrofishing Minute) by Season During the BVPS 2002 Fisheries Survey 5.18 Catch Per Unit of Effort (CPUE as Fish/Electrofishing Minute) by Season During the BVPS 2003 Fisheries Survey (2 sheets) 5.19 Unit 1 Cooling Reservoir Monthly Sampling Corbicula Density Data for 2003 from BVPS 5.20 Unit 2 Cooling Reservoir Monthly Sampling Corbicula Density Data for 2003 from BVPS 5.20.1 Zebra Mussel Mortality During Clamicide Treatments, BVPS, 2003 5.21 Zebra Mussel Substrate Settlement Results From BVPS, 2003 2003 Annual Environmental Report FENOC (BVPS) iv

LIST OF FIGURES 5.1 Location Map for the 2003 Beaver Valley Power Station Aquatic Monitoring Program Sampling Control and Non-Control Sampling Stations 5.2 Location Map for Beaver Valley Power Station Benthic Organism Survey Sampling Sites for the 2003 Study 5.3 Location Map for Beaver Valley Power Station Fish Population Survey Fish Sampling Sites for the 2003 Study 5.4 Location of Study Area, Beaver Valley Power Station Shippingport, Pennsylvania BVPS 5.5 Comparison of Live Corbicula Clam Density Estimates Among BVPS Unit I Cooling Tower Reservoir Sample Events, for Various Clam Shell Size Groups, 2003.

5.6 Comparison of Live Corbicula Clam Density Estimates Among Unit 2 Cooling Tower Reservoir Sample Events, for Various Clam Shell Size Groups, 2003.

5.6.A Unit 1 Cooling Tower Reservoir Outage Sampling, Corbicula Density Data for March 14 from BVPS, 2003.-

5.7 Comparison of Live Corbicula Clam Density Estimates Among Intake Structure Sample Events, for Various Clam Shell Size Groups, 2003 5.8 Water Temperature and River Elevation Recorded on the Ohio River at the BVPS Intake Structure, During Monthly Sampling Dates, 2003 5.9 Density of zebra mussel veligers (#/m3) collected at Beaver Valley Power Station, Intake Structure, Unit 1 Cooling Tower Reservoir and Unit 2 Cooling Tower Reservoir, 2003.

5.10 Density of zebra mussel veligers (#/m3) collected at Beaver Valley Power.Station, Barge Slip, Splash Pool and Emergency Outfall Basin, 2003.

5.11 Density (#/m2) of settled zebra mussels at Beaver Valley Power Station Intake Structure, Unit 1 Cooling Tower Reservoir and Unit 2 Cooling Tower Reservoir, 2003.

5.12 Density (#/m2) of settled zebra mussels at Beaver Valley Power Station, Barge Slip, Splash Pool and Emergency Outfall Basin, 2003.

6.0 ATTACHMENTS : Environmental Permits and Certificates 2003 Annual Environmental Report v

FENOC (BVPS)

I I This page Intentionally Blank

1.0 -EXECUTIVE

SUMMARY

1.1

-INTRODUCTIlON This report is submitted in accordance with Section 5.4.1 of Appendix B To Facility Operating License No. NPF-73, Beaver Valley Power Station Unit 2, Environmental Protection Plan (Non-Radiological).

Beaver Valley Power Station (BVPS) is operated by FirstEnergy Nuclear Operating Company (FENOC); The Objectives of the Environmental Protection Plan (EPP) are:

  • Verify that the facility is operated in an environmentally acceptable manner, as established by the Final Environmental Statement-Operating License Stage (FES-OL) and other NRC environmental impact assessments.
  • Coordinate NRC requirements and maintain consistency with other Federal, State, and local requirements for environmental protection.

i Keep NRC informed of the environmental effects of facility construction and operation and of action's taken to control those effects.

To achieve the objectives of the EPP, FirstEnergy Corporation, FENOC, and BVPS, have written programs and procedures to comply with -the EPP, protect the environment, and comply with governmental requirements-primarily including the US Environmental Protection Agency (EPA), and the Pennsylvania Department' of Environmental Protection (PA DEP). "Water quality matters identified in the Final Environme'ntal Statements-Operating License Stage (FES-OL) are regulated under the National Pollutants'Dischargei Elimination System (NPDES)'Permit No.

PA0025615. Waste is regulated under EPA Identification No. PAR000040485.' Attachment I contains a listing of permits and registrations for environmental compliance.

-The -BVPS -programs and procedures 'include pre-work and pre-project environmental evaluations, operating procedures, pollution prevention and response programs procedures 'and plans, process improvement and corrective action programs, and human performance programs.

Technical and managerial monitoring of tasks, operations, and other activities are performed.

Any identified challenges, concerns,- or'cuestions, are captured in the FENOC Problem

' Identification and Resolution Program with a Condition Report.

Condition Reports'include investigations, cause determinations, and corrective actions to fix and prevent recurrence.

During 2003 BVPS continued an Aquatic Monitoring Program to evaluate its potential impact on the New Cumberland Pool of the Ohio River, and to provide information on potential impacts to

-BVPS operation from macrofoulers such as Asian clams and Zebra mussels.

1.2

SUMMARY

'AND CONCLUSIONS...

There were no significant environmental events during 2003. One spill occurred that, though reported to the Pennsylvania Department of Environmental Protection (PA DEP), caused no measurable impact to the environment, and isdetailed in Section 4.0 of this report.. Corrective actions were identified for each through the FENOC Process Improvement Program.

2003 Annual Environmental Report I

FENOC (BVPS)

___________________________________________________I I During 2003, no significant changes to operations that could affect the environment were made at Beaver Valley Power Station.

As in previous years, results of the BVPS environmental programs did not indicate any adverse environmental impacts from station operation.

1.3 ANALYSIS OF SIGNIFICANT ENVIRONMENTAL CHANGE During 2003, no significant changes to were made at BVPS to cause significant negative affect on the environment.

1.4 AQUATIC MONITORING PROGRAM The 2003 Beaver Valley Power Station (BVPS) Units 1 and 2 Non-Radiological Monitoring Program consisted of an Aquatic Program that included surveillance and field sampling of the Ohio River's aquatic life in the vicinity of the station. The Aquatic Program is conducted annually provide baseline aquatic resources data, to assess the impact of the operation of BVPS on the aquatic ecosystem of the Ohio River, and to monitor for potential impacts of biofouling organisms (Corbicula and zebra mussels) on BVPS operations. This is the 28th year of operational environmental monitoring for Unit 1 and the 17th for Unit 2. As in previous years, the results of the program did not indicate any adverse environmental impact to the aquatic life in the Ohio River associated with the operation of BVPS.

The results of the 2003 benthic macroinvertebrate survey conducted in May and September indicated a normal community structure existed in the Ohio River both upstream and downstream of the BVPS. These benthic surveys are also a continuation of a Fate and Effects Study conducted from 1990 through 1992 for PA DEP to assess the ecosystem impacts of the molluscicides Betz Clamtrol CT-I, CT-2, and Powerline 3627, used to control biofouling organisms at BVPS. To date the results of the benthic studies have not indicated any impacts of operation at the BVPS, including the use these biocides, on the benthic community below the BVPS discharge.

Substrate was probably the most important factor influencing the distribution and abundance of the benthic macroinvertebrates in the Ohio River near BVPS. Soft muck-type substrate along the shoreline found in 2003 and previous years was conducive to segmented worm (oligochaete) and midge (chironomid) proliferation. In 2003, 53 macroinvertebrate taxa were identified. One new taxon was added to the cumulative list of benthic macroinvertebrates collected near BVPS since the inception of this program. Chironomids were the most frequently collected groups in May for both the control and non-control stations. Oligochetes were the most frequently collected groups in September for both the control and non-control stations.

There were no major differences in the community structure between control and non-control stations that could be attributed to operation of BVPS. The overall community structure has changed little since pre-operational years, and program results did not indicate that BVPS operations were affecting the benthic community of the Ohio River.

The fish community of the Ohio River near the BVPS was sampled in May, July, September and November of 2003 with night electrofishing and daytime seining. Results from the 2003 fish 2003 Annual Environmental Report 2

FENOC (BVPS)

surveys indicated that a normal community structure for the Ohio River existed near BVPS based on species composition and relative abundance. Since monitoring began in the early 1970's, the number of identified fish taxa has increased from 43 to 78 for the New Cumberland Pool.

During the survey, forage species were collected or observed in the highest numbers, principally emerald shiner, spottail shiner, and gizzard shad. This indicated a healthy fish community, since game species rely on the availability of abundant forage for survival. Shorthead redhorse, sauger, and Golden redhorse were also commonly collected in 2003. Variations in the'annual catch were probably attributable to normal fluctuations in the population size of the forage species and the predator populations that depend on them. Forage species, such as gizz'ard shad, spottail shiner, and emerald shiners, which have high reproductive potential, frequently respond to changes in the environment with large fluctuations in population size. This in turn influences the population of predator species.

In 2003, species composition remained comparable among control and non-control stations.

Common taxa collected included shorthead redhorse, spottail shiner, sauger, and golden redhorse sucker. The catch per unit effort (number of fish per minute) for electrofishing sampling in 2003 was 1.28 fish. This was slightly lower compared with results of the previous. year when electrofishing resulted in 1.98 fish collected per minute. These differences may have been the result of. population changes, differences in sampling schedule, -or caused by environmental conditions (e.g. turbidity, waves, water temperature, flow) on specific electrofishing sampling dates that affected fish distribution or collection gear efficiency.

Little difference in the species composition of the catch was observed between the control (Station 1) and non-control (Stations 2A, 2B and 3) collections. Habitat preference and availability were probably the most important factors affecting where and when fish were collected. In 2003, there was no indication of negative impact to the fish community in the Ohio Riverfrom the operation of BVPS....

The monthly reservoir ponar samples collected in' Units 1 and 2 cooling towers and the intake during 2003 indicated that Corbicula were entering and colonizing the reservoirs. Overall, the numbers of Corbicula collected in the samples were comparatively low, which continued the trend over, the past few years of fewer. Corbicula and reflected a water-body-wide trend observed in the Ohio'River.

Since 1991, zebra mussels progressively moved upstream in the Ohio River.Ind 1993, zebra mussels were identified 50 miles downstream of BVPS.' In 1995, live zebra'mussels were collected for the first time by divers in the-BVPS main itake' and auxiliary intake structures during scheduled cleanings. Densities were generally low. During 1997, zebra mussel veligers, juveniles and adults were observed for the first'time in' sample collections. Densities-of zebra mussels in samples increased significantly in 1998 and 1999.

Overall, both the number of observations of settled mussels and the densities of veligers at BVPS in 2003 were similar to that found in 2002. If trends continue and the number of zebra mussels in 2003 Annual Environmental Report 3

FENOC (BVPS)

I I the Ohio River should remain high in 2004, BVPS should maintain their diligent zebra mussel monitoring and control program.

As in previous years, data from the BVPS environmental programs did not indicate any adverse environmental impacts from station operation.

2.0 ENVIRONMENTAL PROTECTION PLAN NON-COMIPLIANCES There were no Environmental Protection Plan non-compliances identified in 2003.

3.0 CHANGES INVOLVING UNREVIEWED ENVIRONMENTAL QUESTIONS No Unreviewed Environmental Questions were identified in 2003. Therefore, there were no changes involving an Unreviewed Environmental Question.

4.0 NONROUTINE ENVIRONMENTAL REPORTS During 2003, BVPS made one non-routine environmental report to the Pennsylvania Department of Environmental Protection (PA DEP).

NOTE 1:

The BVPS National Pollutants Discharge Elimination System (NPDES) Permit No. PA0025615 was amended and made effective on June 1, 2003. A copy of the draft permit for public comment and the final permit as amended, were submitted to the USNRC in accordance with the EPP.

NOTE 2:

Required reports under the National Pollutants Discharge Elimination System (NPDES) Permit are not included in this section. They are included with the applicable submittal of the monthly Discharge Monitoring Reports (DMR).

Copies of DMRs and attached reports are submitted to the USNRC, and are, therefore, not included in this report.

4.1 Spill from the Unit 1 Sewage Treatment Plant:

A release of approximately 800 gallons of semi-treated liquid occurred from the plant on January 17, 2003. The liquid had completed three steps in its processing, and was released just prior to the final step of chlorination. The incident was documented and investigated in the FENOC Problem Identification & Resolution Program under Condition Report CR-03-00540. Human performance and mechanical problems were identified as causes, and corrective actions were implemented. No harm to the environment was identified. In accordance with spill response regulations, the PA DEP was initially notified by telephone, and a letter report was submitted on January 19, 2003 under BVPS Letter Number NPD3VPO:1239.

2003 Annual Environmental Report 4

FENOC (BVPS)

5.0 AQUATIC MONITORING PROGRAM

5.1 INTRODUCTION

This section of the report summarizes the Non-Radiological Environmental Program conducted for the Beaver Valley Power Station 1 (BVPS) Units.1 and 2; Operating License Numbers DPR-66 and NPF-73. This is a non-mandatory program, because on February 26, 1980, the Nuclear Regulatory Commission (NRC) granted BVPS's request to delete all of the Aquatic Monitoring Program, with the exception of the fish impingement program (Amendment No. 25), from the Environmental Technical Specifications (ETS). In 1983, BVPS was permitted to also delete the fish impingement studies from the ETS program of required sampling along with non-radiological water quality requirements. However, in the interest of providing an uninterrupted database, BVPS has continued the Aquatic Monitoring Program.

5.1.1 Obiectives of the Program The objectives of the 2003 environmental program were:

(1) To monitor for any possible environmental impact of BVPS operation on the benthic macroinvertebrate and fish communities in the Ohio River; (2) To provide a low level sampling program to continue an uninterrupted environmental database for the Ohio River near BVPS, pre-operational to present; and (3) To evaluate the presence, growth, and reproduction of macrofouling Corbicula (Asiatic clam) and zebra mussels (Dreissena spp.) at BVPS.

5.1.2 Scope of Services Stantec Consulting Inc. (Stantec) was contracted to perform the '2003:Aquatic Monitoring Program as specified in BVBP-ENV-001

- 'Aquatic Monitoring (procedural' guide).

This procedural guide references and describes in detail the field and laboratory procedures used in the various monitoring programs, as well as thle'data analysis and reporting requirements.'These procedures are summarized according to task below.

5.1.3 Benthic Macroinvertebrate Monitoring' The benthic macroinvertebrate monitoring program 'consisted of benthic sampling using a Ponar grab sampler at four stations on'the Ohio River.'Prior to 1996,Aduplicate sampling 'occurred at Stations 1, 2A, and 3, while triplicate sampling occurred at Station 2B(i.e., one sample at each shoreline and mid-channei) (Figures 5.1 and 5.2). In 1996, a review of the sampling design indicated that sampling should be performed in triplicate at each station to -conform to standardized U.S. Environmental Protection Agency (USEPA) procedures. Therefore, starting in 1996, triplicate'samples were taken at Stations 1, 2A,'arid 3, as'in 1995, with triplicate samples also collected at each shore and mid-channel location at Station 2B. A petite Ponar dredge was used to collect these samples, replacing the'standard Ponar dredge'used in prior studies. This 2003 Annual Environmental Report 5

FENOC (BVPS)

II sampling was conducted in May and September 2003. For each 2003 field effort, 18 benthic samples were collected and processed in the laboratory.

5.1.4 Fish Monitorina The fish monitoring program consisted of seasonal sampling (May, July, September, and November) using boat electrofishing and seining techniques. Boat electrofishing was conducted at night along both shorelines at Stations 1, 2A, 2B, and 3 (Figure 5.3). Seining occurred at Stations 1 and 2B during the day and generally was performed in late afternoon or early evening.

All field procedures and data analysis were conducted in accordance with the procedural guide.

5.1.5 Larval Cages/Zebra Mussel Scraper/Bridal Veil Samplers/Pump/Biobox Sampling Larval cages (two long term and two short term) were set in the project intake structure to sample for Corbicula beginning in 1996. The cages continued to be used to monitor for Corbicula through August 1997. Results from a study conducted from April through June 1997 to compare short-term larval cage and petite Ponar sample results indicated that Ponar sampling provided comparable results to short-term larval cages for monthly sampling. In August 1997, Ponar sampling replaced short-term larval cage sampling. Long-term cages were used until May 1998 when all larval cages were removed.

Wall scraping samples were collected monthly from the Unit I cooling tower, the Unit 2 cooling tower, the barge slip, and the intake wall in 1996 and 1997. Wall scrapings were taken with a D-frame scraper, with five scrapes of approximately 2 ft each made per sample at the sampling locations. In 1998, two additional locations were added; the emergency outfall (June through November) and the emergency outfall impact basin (August through November). In 1999 through 2003, these added sites were sampled from March through November.

The intake sampling and wall scraping sampling was historically conducted once per month, yearlong. Beginning in December 1997, it was decided to forego sampling in December and January of each year, since buildup of the target organisms, Corbicula and zebra mussels, does not occur in these cold water months. Monthly sampling has been maintained throughout the balance of the year.

A pump sample for zebra mussel veligers was collected at the barge slip location monthly from April through October in 1996 and 1997. The scope of the sampling was expanded in 1998 to also include the intake structure. In June 1998, the emergency outfall and emergency outfall impact basin locations were also added. Additional pump samples were collected from the cooling tower of Unit 1 and Unit 2 in October 1998. At the request of BVPS, sampling was extended through November in 1998. In 2003, these additional locations were sampled from March through November.

In April 1998, a biobox was set up at the emergency outfall basin to monitor for settling zebra mussels. The biobox was checked each month, and four substrate plates were removed and analyzed in November 1998. In 2001, the biobox set up at the emergency outfall basin was replaced with two more efficient aquarium style bioboxes. These bioboxes continued to be used 2003 Annual Environmental Report 6

FENOC (BVPS)

at this location through 2002. The bioboxes, were 'also used to determine the efficacy of the periodic treatments to control zebra mussel and Corbicula in the facility. In 2003 the bioboxes were used during zebra mussel and Corbicula treatments to monitor the treatment's efficacy only.

5.1.6 CorbiculalZebra Mussel Density Determinations During the scheduled shutdown period for each unit, each cooling tower reservoir bottom was sampled by petite Ponar at standardized locations within the reservoir. Counts of live and dead clams and determination of density were made.

During all Corbicula/zebra mussel sampling activities, observations were made of the shoreline

- and other adjoining hard substrates for the presence of macrofouling species.

5.1.7 Monthly Activity Reports Each month activity reports were prepared sufiimarizing the activities that took place during the previous month. The reports. included the results of the monthly Corbiculalzebra mussel monitoring'including any trends observed and a'ny preliminary results available from the benthic and fisheries programs. The reports addressed progress made on each task, and reported any observed biological activity of interest.

5.1.8 Site Description BVPS is located on an approximately 501-acre tract of land on the south bank of the Ohio River in the Borough of Shippingport, Beaver-County, Pennsylvania. The Shippingport Atomic Power Station once shared the site with BVPS before being decommissioned. Figure 5.4 is a plan view of BVPS. The site is approximately.1 mile (1.6 Iam) from Midland, Pennsylvania; 5 miles (8 km) from East Liverpool, Ohio; and 25 miles (40 Im) from Pittsburgh, Pennsylvania. The population within a 5-mile (8 km) radius of the plant is approximately 18,000. The Borough of Midland, Pennsylvania has a population of approximately 12,617.

The site lies along the Ohio River in a valley, which has a gradual slope that extends from the river (Elevation 665 ft (203 m) above mean sea level) to an elevation of 1,160 ft (354 m) along a ridge south of BVPS. The plant entrance elevation at the station is approximately 735 ft (224 m) above mean sea level.

The station is situated on the Ohio River at River Mile.34.8 (Latitude: 400 36' 18"; Longitude:

80°-26' 02") at a location on 'the New!Cumberland Pool :that is 3.3 river miles (5.3 km) downstream from Montgomery Lock 'and Dam and 19.4 'miles (31.2 1km) upstream from New Cumberland Lock and Dam. The Pennsylvania-Ohio-West Virginia border is'5.2 river miles (8.4 km) downstream from the site. The river flow is regulated by a series of dams and reservoirs on the Beaver, Allegheny, Monongahela, and Ohio Rivers and their tributaries.

2003 Annual Environmental Report 7

FENOC (BVPS)

II Ohio River water temperatures generally vary from 320F to 840F (00C to 290C). Minimum and maximum temperatures generally occur in January and July/August, respectively.

BVPS Units 1 and 2 have a thermal rating of 2,660 megawatts (MW). Units 1 & 2 have a design electrical rating of 835 MW and 836 MW, respectively. The circulating water systems for each unit are considered a closed cycle system with continuous overflow, using a cooling tower to minimize heat released to the Ohio River; Commercial operation of BVPS Unit I began in 1976 and Unit 2 began operation in 1987.

5.2 AQUATIC MONITORING PROGRAM The environmental study area, established to assess potential impacts, consists of four sampling stations each having a north and south shore (Figure 5.1). Station 1 is located at River Mile (RM) 34.5, approximately 0.3 mile (0.5 km) upstream of BVPS and is the control station. Station 2A is located approximately 0.5 mile (0.8 km) downstream of the BVPS discharge structure in the main channel. Station 2B is located in the back channel of Phillis Island, also 0.5 mile downstream of the BVPS discharge structure. Station 2B is the principal non-control station because the majority of discharges from BVPS Units 1 and 2 are released to this back channel.

Station 3 is located approximately two miles (3.2 km) downstream of BVPS.

Sampling dates for each of the program elements are presented in Table 5.1.

The following sections summarize the findings for each of the program elements.

5.2.1 Benthic Macroinvertebrate Monitoring Program 5.2.1.1 Objectives: The objectives of the benthic surveys were to characterize the benthic macroinvertebrates of the Ohio River near BVPS and to determine the impacts, if any, of BVPS operations.

5.2.1.2 Methods:

Benthic surveys were scheduled and performed in May and September 2003. Benthic samples were collected at Stations 1, 2A, 2B, and 3 (Figure 5.2), using a petite Ponar grab sampler. Triplicate samples were taken off the south shore at Stations 1, 2A, and 3.

Sampling at Station 2B, in the back channel of Phillis Island, consisted of triplicate petite Ponar grabs at the south side, middle, and north side of the channel (i.e., sample Stations 2B1, 2B2, and 2B3, respectively).

The contents of each grab were gently washed through a U.S. Standard No. 30 sieve and the retained contents were placed in a labeled bottle and preserved in ethanol. In the laboratory, rose bengal stain was added to aid in sorting and identifying the benthic organisms.

Macroinvertebrates were sorted from each sample, identified to the lowest taxon practical and counted. Mean density (number/m2) for each taxon was calculated for each replicate. Four indices used to describe the benthic community were calculated:

Shannon-Weiner diversity index, evenness (Pielou, 1969), species richness, and the number of taxa. These estimates provide an indication of the relative quality of the macroinvertebrate community.

2003 Annual Environmental Report 8

FENOC (BVPS)

5.2.1.3 Habitats: Substrate type is an important factor in determining the composition of the benthic community. Two distinct benthic habitats exist-in the Ohio River near BVPS. These habitats are the result of damming, channelization, and river traffic. During sampling, shoreline habitats were generally soft'muck substrates composed of sand, silt, and detritus. An exception occurred along the' north shoreline of Phillis Island at Station 2A where clay and sand dominated.

The other distinct habitat, hard substrate (gravel and cobble), was located in mid-channel 'of the back channel of Phillis Island. The hard substrate is probably the result of channelization and scouring by river currents.

5.2.1.4

'Results: Fifty-three (53) macroinvertebrate' taxa were identified during the 2003 monitoring program (Tables 5.2, -5.3.1 and 5.3.2).

A mean density of ' 9,532 macroinvertebrates/m2 was collected in May and 4,243/m2 in September (Table'5.4).- As in previous years, the macroinvertebrate assemblage during 2003 was dominated'by. burrowing organisms, typical 'of soft unconsolidated substrates.

Oligochaetes (segmented worms) and chironornid (midge fly) larvae were abundant (Table 5.4).

Forty-one (41) taxa were present in the May samples, and thirty-five (35) taxa in the September samples (Table 5.3.1 and 5.3.2). Nineteen (19) :of the 53 taxa were present in both May and September.

The Asiatic clam (Corbicula sp.) has been observed in the Ohio River near BVPS.from 1974 to present.- Zebra mussels were first collected in the BVPS benthic samples in 1998. Adult zebra mussels, however, were detected in 1995 and 1996 by divers in the BVPS main and auxiliary intake structures during scheduled cleaning operations.

Zebra mussel veligers, adults and juveniles were collected during the 1997-2003 sampling programs (see Sections 51.4 and 5.1.5, Zebra Mussel Monitoring Program).

In 2003, one taxon, a mollusk was added to the cumulative taxa list of macroinvertebrates collected near BVPS (Table 5.2).

No state or Federal threatened or endangered macroinvertebrate species were collected during 2003.

5.2.1.5 Community Structure and Spatial Distribution for May 2003 (Table 5.4):

Chironomids accounted for the highest mean density of macroinvertebrates and oligochaetes had the second highest (5,0601rn2 and 3,906/m2, respectively) in May 2003. Organisms other than oligochaetes, chironomids and mollusks 'had the third highest mean density in May 2003

.(294/m2) while mollusks had the fourth highest mean density (272/m2).

For September 2003 (Table 5.4): Oligochaetes accounted for 'the highest mean density of macroinvertebrates and mollusks had the second highest (1,591/if2'and:1,383/m2, respectively).

Chironomids had the third highest mean density in September 2003 (846/m2) while the "others" category had the fourth highest mean density (423/m2).

In May, the highest density of macroinvertebrates (22,188 organisms/m2) occurred'at Station 2B1. In' September, the highest density of macroinvertebrates occurred at Station 2B2 (8,600/ m2).' The lowest mean density of

'organisms in May (4,128/m2) occurred at -Station 2B3, while in September the' lowest mean density of macroinvertebrates occurred at station 2A (1,247ii2).

2003 Annual Environmental Report 9

FENOC (BVPS)

I l 5.2.1.6 Comparison of Control and Non-Control Stations:

For this analysis, Station 1 was designated the control station, because it is always out of the influence of the BVPS discharge and Station 2B (mean density of Station 2B11, 2B2, and 2B3) the non-control station, since it is the station subjected to BVPS's discharge most regularly. Stations 3 and 2A may be under the influence of the plume under certain conditions, but it is unlikely that they are regularly influenced by BVPS.

The mean number of macroinvertebrates in the non-control station was approximately 1.5 times higher than that of the control station in May (Table 5.5). The density of macroinvertebrates found at the non-control station (10,750/ m2) versues the control station (7,095/ m2). The density of oligochaetes was about 3.2 times higher at the non-control station (4,615/m2) than at the control station (1,462/m3). Chironomids was the dominant group at both locations although they contributed to 79 percent of the macroinvertebrates collected at the control station, and only 49 percent at the non-control station. These differences probably reflect the natural differences in substrate and natural heterogeneous distributions of these organisms between the stations rather than project-related impacts.

In September, the density of macroinvertebrates present was about 2.9 times higher at the non-control (6,464/m2) than at the control station (2,193/m2). Oligochaetes, chironomids, mollusks, and others occurred at higher densities at the non-control than the control stations. As in May, the differences observed between Station 1 (control) and Station 2B (non-control) were probably related to observed differences in habitat at each station. Differences were within the expected range of variation for natural populations of macroinvertebrates.

Indices that describe the relative diversity, evenness, and richness of the macroinvertebrate population structure among stations and between control and non-control sites were calculated. A higher Shanon-Weiner diversity index indicates a relatively better structured assemblage of organisms, while a lower index generally indicates a low quality or stressed community.

Evenness is an index that estimates the relative contribution of each taxon to the community assemblage, the closer to one, the healthier the community. The community richness is another estimate of the quality of the macroinvertebrate community with a higher richness number indicating a healthier community In May the diversity, evenness and richness indices were higher (i.e. indicative of a healthier community) in the 2B (non-control) than in the control station (Station 1) (Table 5.6). In September, the reverse was true, although all of the indices were generally higher at the control and non-control station, compared to May. The differences in the various indices were within the range that would normally be present in a waterbody such as the Ohio River. No impacts of the BVPS on the benthic community, as measured by differences between control and non-control zones, were evident in either May or September.

5.2.1.7 Seasonal Comparison: The density of benthic organisms observed was slightly lower in May 2003 as compared to September 2003 (Table 5.3.1 and 5.3.2). Forty-one (41) taxa were identified in May, and 35 in September. Chironomids were the most commonly collected macroinvertebrates in May and oligochaetes were the most common in September.

2003 Annual Environmental Report 10 FENOC (BVPS)

The Shannon-Weiner diversity indices in May 2003 collections ranged from 0.27 at Station 1 to 0.79 at Station 2B3, a non-control station (Table 5.6). In May evenness ranged from 0.46 at Station I to 0.67 at Station 2B3. Richness was greatest at Station 2B32 (4.10) and lowest at Station 1 (0.59). The Shannon-Weiner diversity indices in May 2003 collections ranged from 0.27 at Station 1 to 0.79 at Station 2B3 (Table 5.6). In May evenness ranged from 0.46 at Station 1 to 0.67 at Station 2B3. Richness was greatest at non-control Station 2B32 (4.10) and lowest at Station 1 (0.59). The diversity of the macroinvertebrate community in September was generally higher than in May. Diversity ranged from 0.70 at Station 2B2 to 0.94 at Station 1. Evenness was also greater in September than' in May and ranged from 0.63 at Station 2B2 to 0.89 at Station 2A. Richness was greatest at Station 1 (3.03) and lowest at Station 2B2 (2.00). The higher indices in September compared to May are typical and due to the recruitment of many species (e.g. aquatic insects) over the summer months.

5.2.1.8 Discussion: Substrate was probably the most important factor controlling the distribution and abundance of the benthic macroinvertebrates in the Ohio River near BVPS. Soft, mucky substrates that existed along the shoreline'are conducive to oligochaete, chironomid, and mollusk habitation and limit species of macroinvertebrates that require a more stable bottom.

The density of macroinvertebrates in May and September 2003 fell within the range of densities

-of macroinvertebrate collected at BVPS in previous years. The introduction of zebra mussels and Corbicula into the Ohio River may impact the benthic community structure. However, the community structure has changed little since pre-operational years, and the available evidence does not indicate that BVPS operations have affected the benthic community of the Ohio River (Table 5.7).

5.3 FISH 5.3.1 Objectives Fish sampling was conducted to provide a continuous baseline of data and to detect possible changes that may have occurred in the fish populations in the Ohio River near BYPS.

5.3.2 Methods Adult fish surveys were scheduled and performed in May, July, September, and November 2003.

During each survey, fish were sampled by standardized electrofishing techniques at four stations (Stations 1, 2A, 2B and 3) (Figure 5.3)., Seining was performed at Station 1 (north shore) and Station'2B (south shore of Phillis Islanid), to 'sample species that are gen'erally under-represented in electrofishing catches (e.g., young-of-the-year fish and small cyprinids).

Night electrofishing was'conducted using a boom electroshocker and floodlights mounted to the bow of the boat. 'A Coffelt variable1yoltage, pulsed-DC electrofishing unit powered by a 3.5-kW generator was used. The voltage selected depended on water conductivity and was 'adjusted based on the amperage of the current passing through the water. The north and south shoreline areas at each station were shocked for at least 10 minutes of unit "on" time (approximately five minutes along each shore) during each survey.

2003 Annual Environmental Report 11 FENOC (BVPS)

I I When large schools of fish of a single non-game species such as gizzard shad and shiners were encountered during electrofishing efforts, all of the stunned fish were not netted and retrieved onboard the boat. A few fish were netted for verification of identity, and the number of observed stunned fish remaining in the water was estimated. The size range of the individual fish in the school was also estimated and recorded.

This was done in an effort to expedite sample processing and cover a larger area during the timed electrofishing run. Regardless of the number of individuals, all game fish were boated when observed.

Fish seining was performed at Station 1 (control) and Station 2B (non-control) during each scheduled 2003 BVPS fishery survey. A 30-ft long bag seine made of 1/4-inch nylon mesh netting was used to collect fish located close to shore in 1 to 4 ft of water. Three seine hauls were performed at both Station 1 (north shore) and Station 2B (south shore of Phillis Island) during each survey.

Fish collected during electrofishing and seining efforts were processed according to standardized procedures. All captured game fishes were identified, counted, measured for total length (nearest 1 mm), and weighed (nearest 1 g). Non-game fishes were counted, and a random subsample of lengths was taken.

Live fish were returned to the river immediately after processing was completed. All fish that were unidentifiable or of questionable identification and were obviously not on the endangered or threatened species list were placed in plastic sample bottles, preserved, labeled and returned to the laboratory for identification. Any fish that had not previously been collected at BVPS was retained for the voucher collection. Any threatened or endangered species (if collected) would be photographed and released.

5.3.3 Results Fish population surveys have been conducted in the Ohio River near BVPS annually from 1970 through 2003. These surveys have resulted in the collection of 73 fish species and 5 different hybrids (Table 5.8).

In 2003, 252 fishes representing 26 taxa were collected (i.e., handled) during BVPS surveys by electrofishing and seining (Tables 5.9 and 5.10). All taxa collected in 2003 were previously encountered at BVPS. An estimated additional several hundred individuals were observed but not handled during electrofishing surveys (Table 5.15). In addition, large schools of emerald shiners were observed during sampling runs. The most common species in the 2003 BVPS surveys, collected by electrofishing and seining combined, were shorthead redhorse sucker (26.2 percent of the total catch), sauger (16.3 percent), spottail shiner (13.9 percent), and black buffalo (13.1 percent).

The remaining 23 species combined accounted for 30.5 percent of the total handled catch. The most frequently observed (handled and not handled combined) fish in 2003 were emerald shiner (Tables 5.9, 5.10, and 5.15). Game fishes collected during 2003 included channel catfish, flathead catfish, white bass, bluegill, largemouth bass, smallmouth bass, rock bass, sauger, walleye, black crappie and spotted bass hybrid. Game fishes represented 33.0 percent of the total handled catch, 11.8 percent of which were sauger.

A total of 211 fish, representing 26 taxa, was collected by electrofishing in 2003 (Table 5.9).

2003 Annual Environmental Report 12 FENOC (BVPS)

Shorthead redhorse and sauger accounted for the largest portion of the 2003 electrofishing catch (19.4 percent and 11.8, respectively) followed by golden redhorse sucker (11.4 percent). None of the other species collected contributed to greater than six (6) percent of the total catch.

A total of 41 fish representing 4 taxa was collected by seining in 2003 (Table 5.10). Fish taxa collected were spottail shiner (85.4 percent of-the total catch), emerald shiner (7.4'percent),

bluntnose minnow (4.9'percent) and freshwater drum (2.3 percent). No game:species were collected during seining.

A total of 80 fish representing 15 species was captured during the May 2003 sample event (Table 5.11). A total of 43 fish was collected during electrofishing and 37 during seine netting. Golden redhorse (20.9 percent of the total catch) was the most common species boated during the electrofishing effort. Spottail shiner (94.6 percent of the total catch) was the most frequently collected species during the seining efforts.

A total of 53 fish representing 15 species was captured during the July 2003 sample event (Table "5.12). A total of 50 fish -was collected'during electrofishing and three (3) -during seining.

Shorthead redhorse (28.0 percent of the total catch) was the most common species boated during the electrofishing' effort. Emerald shiner (66.7 percent of the' total catch) was the'most frequently collected species during the seining efforts.

During 'the September sample event, 31 fish representing 12 taxa were collected'(Table 5.13).

This was the lowest 'total catch during the four months that were sampled in 2003 (May, July, September and November).

A total of 31 fish was collected during electrofishing and none during seining. Shorthead redhorse (22.6 percent of the total catch), gizzard shad and black buffalo (12.8 percent each) were the most common species boated during the electrofishing effort.

'During the November sample event, 88 fish representing 17 taxa were captured (Table 5.14). A total of 87 fish were collected during electrofishing'and one during seining. Shorthead redhorse (19.5 percent of the total catch) and freshwater drum (17.2'percent) were the most common species boated during the electrofishing effort. 'Emerald shiner was the only species collected during the seining efforts in November.

At the request of the Pennsylvania Fish' and Boat Commission (PFBC), electrofishing catch' rates were calculated as fish per minute (i.e.,:power on 'time) 'of sampling for 2001 through 2003.

Electrofishing catch rates are presented in Tables 5.16, 5.17, and 5.18 for' fish that were 'boated and handled during the 2001 through 2003'sur'eys by season. Note that because of security concerns after September 11, 2001 fisheries efforts were not completed in September and November 2001.

In 2003, the annual catch rate was 1.28 fish per minute. The greatest catch rate in 2003 occurred in November (winter) (2.12 fish/ electrofishing minute). A large number of shorthead redhorse, freshwater drum, and golden redhorse contributed to this total. The lowest catch rate occurred in September (fall) with a rate of 0.77 fish! electrofishing minute.

2003 Annual Environmental Report FENOC (BVPS) 13

II In 2002, the annual catch rate was 1.98 fish per minute. The greatest catch rate in 2002 occurred in November (winter)(3.63 fish/electrofishing minute). This was the highest seasonal catch rate of the three years that were compared. A large number of gizzard shad contributed to this total.

The lowest catch rate occurred in July (summer) with a rate of 1.08 fish/electrofishing minute.

In 2001, the annual catch rate was 1.28 fish per electrofishing minute; however, this is not directly comparable to 2002 and 2003 catch rates, since September and November were not sampled. The greatest electrofishing catch rate was in May (1.70 fish/electrofishing minute).

The lowest catch rate was observed in July (0.85 fish/electrofishing minute).

5.3.4 Comparison of Control and Non-Control Stations The results of the electrofishing sampling effort (Table 5.9) did not indicate any major differences in species composition between the control station (1) and the non-control Stations 2A, 2B, and 3.

A greater number of fish representing more species was captured at non-control stations than control stations. This was most likely due to the extra effort expended at non-control stations versus control stations (i.e., there are three non-control stations and only one control station).

The seine data for 2003 (Table 5.10) indicated no major differences in species composition between control and non-control stations. The total number of fish captured at the control station was larger than at the non-control station 91.9 percent of those fish (spottail shiner) were collected during a May 2003 collection.

5.3.5 Discussion The results of the 2003 fish surveys indicated that there is a normal community structure in the Ohio River in the vicinity of BVPS based on species composition and relative abundance of fish observed during the surveys. Forage species were collected in the highest numbers.

Variations in annual catch were probably attributable to normal fluctuations in the population size of the forage species and the predator populations that rely on them. Forage species, such as spottail shiner and emerald shiner with high reproductive potentials, frequently respond to changes in natural environmental factors (competition, food availability, cover, and water quality) with large fluctuations in population size, which could be the reason for the large numbers of emerald shiners and spottail shiner observed in 2003. This, in turn, influences their appearance in the sample populations during annual surveys. Spawning/rearing success due to abiotic factors is usually the determining factor of the size and composition of a fish community.

In addition, differences in electrofishing catch rate can be attributed to environmental conditions that prevail during sampling efforts. High water, increased turbidity, and swift currents that occur during electrofishing efforts in some years can decrease the collection efficiency of this gear.

In 2003, species composition remained comparable among stations. Common taxa collected in the 2003 surveys by all methods included spottail shiner, emerald shiner, redhorse sucker species, 2003 Annual Environmental Report 14 FENOC (BVPS)

golden redhorses sucker, sauger, quillback, and smallmouth'bass. Little difference in the species composition of the catch was observed between the control (1) and non-control stations (2A, 2B and 3). Habitat preference and availability were probably the most important factors affecting where and when different species of fish are collected.

5.4 CORBICUJLA MONITORING PROGRAM 5.4.1 Introduction The introduced Asiatic clam (Corbiculafluminea) was first detected in the United States in 1938 in the Columbia River near Knappton, Washington (Burch 1944). It has since spread throughout most of the country, inhabiting any suitable freshwater habitat. Information from prior aquatic surveys has demonstrated the presenceof Corbicula in the Ohio River in the vicinity of the BVPS, and the plant is listed in NUREG/CR-4233 (Counts 1985).

One adult Asiatic clam is capable of producing many thousands of young called early juveniles.

These early juveniles are very small (approximately, 0.2 mm) and will easily pass through the water passages of a power plant. Once the juveniles settle on the substrate, rapid growth occurs.

If Corbicula develop within a power plant's water passages, they can impede the flow of water through the plant, especially through blockage of condenser tubes and small service water piping.

Reduction of flow may be so severe-thit 'a plant shutdown is necessary. 'Corbicula are of particular concern when they develop undetected in emergency systems where the flow of water is not constant (NRC, IE Bulletin 81-03)'.'--

The Corbicula Monitoring Program at BVPS includes sampling the circulating river water and the service' water'systems of the BVPS (intake structure and cooling towers).

This report describes this Monitoring Program and the results of the field and plant surveys conducted in 2003.

5.4.2 Monitoring 5.4.2.1 -

Objectives: The objectives of the ongoing Monitoring Program are to evaluate the presence of Corbicula at BVPS, and to evaluate the potential for and timing of infestation of the BVPS. This program'is conducted in conjunction with a program to monitor for the presence of macrofouling zebra mussels (see Section's 5.15'and 5.1.6).

5.4.2.2 Methods: Cooling Towers - Monthly Reservoir Sampling Corbicula enter the BVPS from the Ohio River by passing through the water intakes, and eventually settle in low flow areas including the lower reservoirs of the Units 1 and 2 cooling towers. The density and.growth of these Corbicula were monitored by collecting monthly samples from the lower reservoir sidewalls and sediments. 'The sampler used on the sidewalls consisted of a D-frame net attached behind a 24-inch long metal scraping edge. This device was connected to a pole long enough to allow the sampler to extend down into the reservoir area from 2003 Annual Envirornental Report 15 FENOC (BVPS)

Il the outside wall of the cooling tower. Sediments were sampled with a petite ponar.

In 2003, once each month (March through November), a single petite ponar grab sample was scheduled to be taken in the reservoir of each cooling tower to obtain density and growth information on Corbicula present in the bottom sediment. Due to unit outage, no samples were collected from Unit I during September or Unit 2 in March and April 2003. The samples collected from each cooling tower were returned to the laboratory and processed. Samples were individually washed, and any Corbicula removed and rinsed through a series of stacked U.S.

Standard sieves that ranged in mesh size from 1.00 mm to 6.29 mm. Live and dead clams retained in each sieve were counted and the numbers were recorded. The size distribution data obtained using the sieves reflected clam width, rather than length. Samples containing a small number of Corbicula were not sieved; individuals were measured and placed in their respective size categories.

Cooling Towers - Corbicula Density Determination Population surveys of both BVPS cooling tower reservoirs have been conducted during scheduled outages (1986 through 2003) to estimate the number of Corbicula present in these structures. Unit I was sampled in 2003.

5.4.2.3 Results:

Unit 1 Cooling Tower - Monthly Reservoir Sampling In 2003, 86 Corbicula (47.7 percent alive) were collected from the Unit I cooling tower basin during monthly reservoir sampling. The largest live Corbicula collected was retained in a sieve with a 4.75-6.29 mm length size range (Table 5.10 and Figure 5.5). The greatest numbers of Corbicula were collected in May (22 individuals). Corbicula were collected in lower numbers in the other months sampled. Scheduled collections were not made in March or April because of unit outage.

Unit 2 Cooling Tower - Monthly Reservoir Sampling In 2003, 276 Corbicula (13.8 percent alive) were collected from the Unit 2 cooling tower reservoir during monthly sampling. The largest live Corbicula collected was within the 4.75-6.29 mm length size range. Corbicula collected were retained by a sieve with a 4.75-6.29 mm length size range (Table 5.20 and Figure 5.6). Individuals were collected from March through November. No collections were made in September because of unit outage.

In 2003, BVPS continued its Corbicula control program (year 14), which included the use of a molluscicide (i.e., Betz CT-I, Betz Powerline 3627) to prevent the proliferation of Corbicula within BVPS.

Initially, BVPS was granted permission by the Pennsylvania Department of Environmental Protection to use CT-1 to target the Unit 1 river and raw water systems, and the Unit 2 service water systems. BVPS phased out the use of CT-1 beginning in 1997 and now uses Powerline 3627.

2003 Annual Environmental Report 16 FENOC (BVPS)

In 1990 through 1993, the molluscicide applications focused on reducing the Corbicula population throughout the entire river water system of each BVPS plant (Units I and 2).

Beginning in 1994 and 1995, the applications targeted only the internal water systems (i.e., not circulating water); therefore, the clamicide concentrations in the cooling towers were reduced during clamicide applications.- Consequently, adult and juvenile Corbicula in the cooling towers often survived the clamicide applications. Reservoir sediment samples taken after clamicide applications represent mortality of Corbicula in the cooling tower only and do not reflect mortality in BVPS internal water systems.

The current clamicide strategy includes three rotations of treatments per year. Each rotation includes separately targeting and treating a unit and sub-system per treatment. For example, the Unit 1 "A" train sub-systems are treated and detoxified before setting up and performing a treatment on the next target, e.g., Unit'2 '"B" train sub-system. In 2003,'clamicide treatments of sub-systems occurred on May 5, June 4, July'22, August 9, October 14, and October 28, 2003 for Unit' 1; and April 25, May 8, July 16, August 8, October 22, and November 4, 2003 for Unit 2 (Table 5.20.1).

Population surveys of both BVPS cooling tower reservoirs were scheduled to be conducted during scheduled outages (1986 through 2003) to estimate the number of Corbicula present in

'these structures. A population survey of Unit I 'Cooling Tower was conducted on March 14, 2003 during a scheduled unit outage, 1,318 Corbicula (46.0 percent alive) were collected from the Unit 1 cooling tower basin during the March outage sampling. The largest clam collected was in the 4.75-6.29 mm length size range (Figure 5.6A).

5.4.2.4 Discussion: The monthly reservoirisediment samples collected in Units 1 and 2 cooling towers during 2003 demonstrated that Corbicula were entering and colonizing the reservoirs. Overall, densities in Unit 1 were similar to that in 2001 and 2002 and in Unit 2 densities were somewhat greater than in 2001 and'2002. The maximum monthly density of

'Corbicula in Unit 1 was 946/m2, which occurred in May. 'The maximum density of clams in Unit 2 was 4,730/rn2, which occurred in July.

The lower density of Corbicula in Unit 1 compared to Unit 2 was consistent with previous' years results'.,The recent decrease of Corbicula at the BVPS returns densities to levels more consistent with densities'in the Ohio River in the mnid 1990's, but well below those present during the 1980's.

5.4.2.5 Corbicula Juvenile Study:

(1) Objective The Corbicula juvenile study was designed to collect data on Corbicula spawning activities and growth of individuals entering the intake from the Ohio River.

(2) Methods Specially constructed clam cages were initially utilized for this study. Each cage was constructed of a 1 ft durable plastic frame with fiberglass screening (1 mm mesh) secured to cover all open areas. Each cage contained approximately 10 lbs of industrial glass beads (3/8-inch diameter) to 2003 Afiiual Environmnental Report 17 FENOC (BVPS)

II provide ballast and a uniform substrate for the clams. The clam cage mesh size permitted only very small clams to enter and colonize the cage.

In 1988 through 1994, the cages were left in place for five months following initial placement.

Changes in procedure were made to better define the time period when Corbicula were spawning in the Ohio River and releasing larvae that could enter BVPS through the intake structure.

Larval cages were maintained in the BVPS intake structure in 1995 according to the following procedure. Each month, two empty clam cages were placed in the intake structure bays. Each cage was left in place for two months, after which time it was removed and examined for clams.

Four clam cages were maintained in the intake structure bays each month throughout 1995-1996.

In February 1996, it was decided to modify the sampling regime so that two of the four cages in the forebay were long-term samplers and the other two were monthly short-term samplers. Each month, the two long-term samplers were pulled; the fine sediment was carefully washed from the cage and any Corbicula present were measured. The cages were immediately redeployed along with any identified Corbicula. The two short-term cages were pulled monthly and the contents removed for laboratory analyses. New short-term cages were then deployed.

Each short-term clam cage removed after the one or two-month colonization period was returned to the laboratory where it was processed to determine the number of clams that had colonized the cage. Corbicula obtained from each cage were rinsed through a series of stacked U.S. Standard sieves ranging in mesh size from 9.5 mm to 0.6 mm. Live and dead clams on each sieve were counted and the numbers were recorded.

The largest and smallest clams were measured to establish a length range for the sample. The size distribution data obtained using the sieves reflected clam width, rather than length.

Observational-based concerns that the clam cages could quickly clog with sediment during high sediment periods and, as a result, not sample effectively, led to an evaluation of an alternate sampling technique. From April through June 1997, a study was conducted to compare the results of the clam cage samplers to a petite ponar dredge technique to determine Corbicula presence and density in the BVPS intake bays. It was hypothesized that using a ponar sampler to collect bottom sediments and analysis of those sediments would provide a more representative sample of Corbicula settlement and growth rates, and had the added benefit of not requiring confined space entry to conduct the sampling.

During the 1998 sampling season, at the request of BVPS personnel, all clam cages were removed after the May 18, 1998 collection. Monthly petite ponar grabs from the forebay in the intake building continued thereafter.

In 2002, the sampling with petite ponar was moved to the Ohio River basin directly in front of the Intake Structure. Collections were made in conjunction with the fisheries sampling (May, July, September, and November). During each sampling month two ponar grabs were taken approximately 20 feet off shore of the intake building. These grab samples were processed in the same manner as when they were collected from within the Intake Structure Building.

2003 Annual Environmental Report 18 FENOC (BVPS)

(3) Results Figure 5.7 presents the abundance and size distribution data for samples collected in the Ohio River near the intake structure by petite ponar in 2003. Corbicula were collected during all four collections (May, July, September, and November). The presence of small individuals (0.01-0.99, 1.00-1.99 and 2.00-3.34) of Corbicula indicated that'successful spawning had occurred.

The number of individuals collected was comparable'to 2001 and 2002 (14 in 2001, 25 in 2002, and 8 in 2003).

(4) Discussion A spring/early-sumrnmer spawning period typically occurs in the Ohio River near BVPS each year when preferred spawning temperatures (60-65° F are reached (Figure 5.8). The offspring from this spawning event generally begin appearing in the sample collections in late-April (Figure 5.7). The settled clamns generally increase in size'throughout the year. The overall low numbers of live Corbicula collected in the intake and cooling towers in 2003, compared to levels in the 1980's, likely reflects a natural decrease in the density of Corbicula in the Ohio River near BVPS.

5.5 ZEBRA MUSSEL MONITORING PROGRAM 5.5.1 Introduction Zebra mussels (Dreissena polvmorpha) are' exotic freshwater mollusks that have ventrally flattened shells generally marked with alternating dark and lighter bands. They are believed to have been introduced into North America through the ballast water of ocean-going cargo vessels probably from Eastern Europe. They were first identified in Lake St. Clair in 1988 and rapidly spread to other Great Lakes and the Mississippi River drainage system, becoming increasingly abundant in the lower, middle, and upper Ohio River in recent years.

Adult zebra mussels can live up to five years and grow to 2 inches in length. North American research suggests'that'each female may be capable of producing over'one mnillion microscopic (veliger larvae) offspring per year, which can easily pass through water intake screens.' They use strong adhesive byssal threads, collectively referred to as the byssus, to attach themselves to any hard surfaces (e.g., boat hulls, intake pipes and other mussels).' Transport of these organisms between water bodies is accomplished in part by boats that have adult mussels attached to their hulls or larvae in their live wells and/or bilges. In anticipation' of zebra mussel infestation and responding to NRC Notice No. 89-76 (Biofouling Agent-Zebra Mussel, November 21, 1989),

BVPS instituted a Zebra Mussel Monitorinig Program in January 1990.

The Zebra Mussel Monitoring Program included the Ohio River and the circulating river water system of the BVPS (intake structire'and cooling'towers). 'This section describes this Monitoring Program and the results obtained during Ohio River and BVPS surveys conducted through 2003.

5.5.2 Monitoring 2003 Annual Environmental Report 19 FENOC (BVPS)

II 5.5.2.1 Objectives: The objectives of the Monitoring Program were:

(1) To identify if zebra mussels were in the Ohio River adjacent to BVPS and provide early warning to operations personnel as to their possible infestation; (2) To provide data as to when the larvae were mobile in the Ohio River and insights as to their vulnerability to potential treatments; and (3) To provide data on their overall density and growth rates under different water temperatures and provide estimates on the time it requires these mussels to reach the size and density that could impact the plant.

5.5.2.2 Methods:

5.5.2.2.1 Intake Structure and Barge Slip: The surveillance techniques used on site were:

  • Wall scraper sample collections on a monthly basis (March through November) from the barge slip and the riprap near the intake structure to detect attached adults;
  • Pump sample collections from the barge slip and outside the intake structure, to detect the planktonic early life forms (March through November); and
  • Sampling of substrate plates used for detection of settled stages in the impact basin below the Emergency outfall (March through November).
  • Sampling of an artificial substrate (bridal veil material) suspended in the Ohio River from the Barge Slip (April through November).

5.5.2.2.2 Cooling Towers: The techniques used in the Unit 1 and Unit 2 cooling tower locations were:

Monthly reservoir scraper sample collections in each cooling tower (March through November); and

  • Pump samples in March through November to detect planktonic life forms.

5.5.2.2.3 Emergency Outfall:

  • Monthly scraper sample collections in the emergency outfall impact basin (March through November); and
  • Pump samples in March through November to detect planktonic life forms.

5.5.2.2.4 Splash Pool:

  • Monthly scraper sample collections in the Splash Pool (March through November); and 2003 Annual Environmental Report 20 FENOC (BVPS)
  • Pump samples in March through November to detect planktonic life forms.

5.5.3 Results

.1.



Zebra mussels were detected in both pump samples (Figures 5.9.and 5.10) and substrate samples (Figure 5.11 and 5.12) in 2003.;'

Zebra mussel veliger pump samples were 'collected from March through November 2003 (Figures 5.9 and 5.10). Densities of veligers generally peaked in July and August. The greatest density of veligers was present in the sample collected from the Ohio River at the Intake Structure in July'(52,560/m3 ). Veligers were present in all samples collected in July. For August and September, veligers were found in five of the-six collection locations. Overall, veliger densities were higher in 2003 than in' 2002.

In 2002, the greatest density collected was 10,693/m3. Whether this was due to an overall increase in numbers of veligers in the Ohio River in'2003 or due'to the limited number'of, samples and the propensity of veligers' to be non-uniformly distributed in the water is uncertain.'

In 2003, settled zebra mussels' were collected in scrape samples at the Barge Slip from June through November and the Unit 2 Cooling T6wer Reservoir in April. None were collected at the Ohio River/ Intake Structure, Unit 1 Cooling Tower Reservoir, the Splash Pool, or the Emergency Outfall Impact Basin (Figures 5.11 and 5.12). The highest density collected from the Barge Slip was 1 1/m2 in September. The mussels collected at the Barge Slip were adult mussels capable of reproducing. 'Compared with 2002, the' collection of adult zebra mussels was similar at the Barge slip'and lower at the Intake/Ohio River where zebra mussels were collected in June and August 2002. Densities, however, remained similar compared to past years.

5.5.4 Discussion From 1991 through 1993, based on reports,'zebra mussels moved progressively upstream from the lower to upper Ohio River. 'In 1994, there were confirmed zebra mussel sightings at locations both upstream and downstream of BVPS, including the Allegheny River. "The July 1995 sighting of zebra mussels at Maxwell Lock and Dam' on tlie'Monongahela Riverestablished the presence

'of these organisms 'within the Allegheny,' Monongahela -and Ohio' Rivers 'in Westem Pennsylvania.

In 1995, live zebra mussels were found by divers in thegBVPS main intake structure and auxiliary intake structure during scheduled cleaning operations.. The 1996 Zebra Mussel Monitoring Program at BVPS did not collect any live zebra mussels at BVPS. During the first quarter 1996 (January aid February) intake bay cleaning, divers observed an undetermined number of zebra mussels in the intake bays. During the second quairter 1996 cleaning, no mussels were reported.

During the third and fourth quarter 1996 intake'bay cleanings, about 6oe-dozen_ mussels were observed each time in Bay C only. None were collected by the divers for confirmation.

During 1997, zebra mussel veligers were' observed in June. Juvenile zebra mussels'appeared in the clam cage and ponar dredge samples.- In November 1997, adult zebra mussels were found in the intake ponar dredge samples.

2003 Annual Environmental Report FENOC (BVPS) 21

I 1>

During the 1998 Zebra Mussel Monitoring Program at BVPS, zebra mussel veligers, juveniles, and an adult were observed in sample collections. A moderate density of zebra mussel veligers was observed during the August through November 1998 samples, indicating that spawning occurred sometime during the late summer.

Juvenile zebra mussels appeared during March sampling. These mussels were 3.5, 3.5, and 4.5 mm in length, which indicates that they were probably young-of-the-year in 1997. Young-of-the-year zebra mussels appeared in September through November. This observation confirms successful zebra mussel spawning in the area around BVPS.

During 1998, zebra mussels were also found on the walls of the main intake structure during each of the quarterly inspections that took place. During the first quarter, greater than 100 zebra mussels/ft2 were present in Bay B, although fewer were present in the other bays. Less than 5 mussels/ft2 were observed during the second quarter inspection that took place in April. Only Bays A and B were inspected, however. A few small zebra mussels were observed during the third quarter inspection; however, any recently settled mussels would be easily missed during a visual inspection. Few (>10/ft2) mussels were also observed during the fourth quarter inspection.

Corbicula were also present in the main intake structure during each quarterly inspection. Zebra mussels were also observed in low densities in the alternate intake structure during the last three quarters of 1998.

In 1999, the number of both veligers and settled zebra mussel increased significantly in the Ohio River near the BVPS. For the first time, the settled zebra mussels were collected in groups rather than as individuals. The density of veligers exceeded 1000/mi3 on many occasions for the first time in 1999.

Overall, both the number of observations of settled mussels were similar in 2003 and 2002. The density of veligers was less in 2002 than 2003 but similar to 2001. Densities, however, remain high compared to past years. Zebra mussels densities in other water systems display significant annual variations due to environmental variables including water temperature and flow conditions. Whether the population of zebra mussels in this reach of the Ohio River is plateauing and only yearly fluctuations are present cannot be determined. In any case, the densities of mussels that presently exist are sufficient to impact the BVPS, if continued prudent monitoring and control activities are not conduced.

5.5.5 Zebra Mussel and Corbicula Control Activities In 2003, BVPS continued its Corbicula and zebra mussel control program (thirteenth year),

which included the use of a molluscicide to prevent the proliferation of Corbicula within BVPS.

BVPS was granted permission by the Pennsylvania Department of Environmental Protection to use CT-I to target the Unit 1 river water system and the Unit 2 service water system.

In 1990 through 1993, the molluscicide applications focused on reducing the Corbicula population throughout the entire river water system of each BVPS plant (Units 1 and 2). In 1994 through 2003, the clamicide applications targeted zebra mussels and Corbicula in the internal water systems; therefore the molluscicide concentrations in the cooling towers were reduced 2003 Annual Environmental Report 22 FENOC (BVPS)

during clamicide applications. Consequently, adult and juvenile Corbicula in the cooling towers often survived the applications. Reservoir sediment samples taken after clamicide treatments represented mortality of Corbicula in the cooling tower only and do not reflect mortality in BVPS internal water systems.

The current clamicide strategy includes three rotations of treatments per year. Each rotation includes separately targeting and treating a unit and sub-system per treatment. For example, the Unit I "A" train sub-systems are treated and detoxified before setting up and performing a treatment on the next target, e.g., Unit 2 "B" train sub-system. In 2003, clamicide treatments of sub-systems occurred on May 5, June 4, July 22, August 9, October 14, and October 28, 2003 for Unit 1; and April 25, May 8, July 16, August 8, October 22, and November 4, 2003 for Unit 2 (Table 5.20.1).

In addition to clamicide treatments, proactive preventive measures were taken that included, at a minimum, quarterly cleaning of the Intake Bays. The bay cleanings are intended to minimize the accumulation and growth of mussels within the bays.

This practice prevents creating an uncontrolled internal colonization habitat.

2003 Annual Environmental Report FENOC (BVPS) 23

L I This page Intentionally Blank

5.6 REFERENCES

Burch, J. Q., 1944. Checklist of West American Mollusks. Minutes, Conchology Club of

-Southern California 38:18.

Commonwealth of Pennsylvania, 1994. Pennsylvania's Endangered Fishes, Reptiles and Amphibians. Published by the Pennsylvania Fish Commission.

Counts, C. C. III, 1985. Distribution of Corbicula fluminea at Nuclear Facilities. Division of Engineering, U.S. Nuclear Regulatory Commission. NUREGLCR; 4233.79 pp.

Dahlberg, M. D. and E. P. Odum, 1970. Annual cycles of species occurrence, abundance and diversity in Georgia estuarine fish populations. Am. Midl. Nat. 83:382-392.

DLC, 1976. Annual Environmental Report, Non-radiological Company, Beaver Valley Power Station. 132 pp.

Volume #1. Duquesne Light DLC, 1977. Annual Environmental Report, Non-radiological Volume #1.

Company, Beaver Valley Power Station. 123 pp.

DLC, 1979. Annual Environmental Report, Non-radiological Volume #1.

Company, Beaver Valley Power Station. 149 pp.

DLC, 1980. Annual Environmental Report, Non-radiological. Duquesne Light Valley Power Station, Unit No. 1. 160 pp.

. Duquesne Light Duquesne Light Company, Beaver DLC, 1981. Annual Environmental Report, Non-radiological. Duquesne Light Company, Beaver Valley Power Station, Unit No. 1. 105 pp. + Appendices.

DLC, 1982. Annual Environmental Report, Non-radiological. Duquesne Light Company, Beaver Valley Power Station, Unit No. 1. 126 pp.

DLC, 1983. Annual Environmental Report, Non-radiological. Duquesne Light Company, Beaver Valley Power Station, Unit No. 1.- 124 pp. + Appendix.

DLC, 1984. Annual Environmental Report, Non-radiological. Duquesne Light Company, Beaver Valley Power Station, Unit No. 1. 139 pp.

i DLC, 1985. Annual Environmental Report, Non-radiological. Duquesne Light Company, Beaver Valley Power Station, Unit No. 1 & 2. 106 pp.

DLC, 1986. Annual Environmental Report, Non-radiological. Duquesne Light Company, Beaver

- Valley Power Station,-Unit No. 1 &2. 152 pp..

DLC, 1987. Annual Environmental Report, Non-radiological. Duquesne Light Company, Beaver

-Valley Power Station, Unit No. 1 & 2. 145 pp.

- I I DLC, 1988. Annual Environmental Report, Non-radiological. Duquesne Light Company, Beaver Valley Power Station, Unit No. I & 2. 161 pp.

DLC, 1989. Annual Environmental Report, Non-radiological. Duquesne Light Company, Beaver Valley Power Station, Unit No. 1 & 2. 145 pp.

DLC, 1990. Annual Environmental Report, Non-radiological. Duquesne Light Company, Beaver Valley Power Station, Unit No. 1 & 2. 181 pp.

DLC, 1991. Annual Environmental Report, Non-radiological. Duquesne Light Company, Beaver Valley Power Station, Unit No. 1 & 2. 165 pp.

DLC, 1992. Annual Environmental Report, Non-radiological. Duquesne Light Company, Beaver Valley Power Station, Unit No. 1 & 2. 164 pp.

DLC, 1993. Annual Environmental Report, Non-radiological. Duquesne Light Company, Beaver Valley Power Station, Unit No. 1 & 2. 90 pp.

DLC, 1994. Annual Environmental Report, Non-radiological. Duquesne Light Company, Beaver Valley Power Station, Unit No. I & 2. 78 pp.

DLC, 1995. Annual Environmental Report, Non-radiological. Duquesne Light Company, Beaver Valley Power Station, Unit No. 1 & 2. 77 pp.

DLC, 1996. Annual Environmental Report, Non-radiological. Duquesne Light Company, Beaver Valley Power Station, Unit No. 1 & 2. 67 pp.

DLC, 1997. Annual Environmental Report, Non-radiological. Duquesne Light Company, Beaver Valley Power Station, Unit No. 1 & 2. 68 pp.

DLC, 1998. Annual Environmental Report, Non-radiological. Duquesne Light Company, Beaver Valley Power Station, Unit No. I & 2. 63 pp.

FENOC, 1999. Annual Environmental Report, Non-radiological. First Energy Nuclear Operating Company, Beaver Valley Power Station, Unit No. 1 & 2. 76 pp.

FENOC, 2000. Annual Environmental Report, Non-radiological. First Energy Nuclear Operating Company, Beaver Valley Power Station, Unit No. 1 & 2. 76 pp.

FENOC, 2001. Annual Environmental Report, Non-radiological. First Energy Nuclear Operating Company, Beaver Valley Power Station, Unit No. 1 & 2. 76 pp.

FENOC, 2002. Annual Environmental Operating Report, Non-radiological. First Energy Nuclear Operating Company, Beaver Valley Power Station, Unit No. 1 & 2. 113 pp.

Hutchinson, G. E., 1967. A treatise on limnology. Vol. 2, Introduction to lake biology and the limnoplankton. John Wiley and Sons, Inc., New York. 1115 pp.

Hynes, H. B. N., 1970. The ecology of running waters. Univ. Toronto Press, Toronto.

NRC, IE Bulletin 81-03: Flow Blockage of Cooling Tower to Safety System Components by Corbicula sp. (Asiatic Clam) and Mytilus sp. (Mussel).

Pielou, E. C., 1969. An introduction to mathematical ecology. Wiley Interscience, Wiley & Sons, New York, NY.

Robins, C. R., R. M. Bailey, C. E. Bond, J. R. Brooker, E. A. Lachner, R. N. Lea, and W. B.

Scott, 1991. Common and Scientific Names of Fishes from the United States and Canada (fifth edition). American Fisheries Society Special Publication No. 20:1-183.

Shiffer, C., 1990. Identification Guide to Pennsylvania Fishes. Pennsylvania Fish Commission, Bureau of Education and Information. 51 pp.

Winner, J. M., 1975. Zooplankton. In: B. A. Whitton, ed. River ecology. Univ. Calif. Press, Berkely and Los Angeles. 155-169 pp.

I 1.

This page Intentionally Blank

TABLES

TABLE 5.1 BEAVER VALLEY POWER STATION (BVPS)

SAMPLING DATES FOR 2003 Study Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Benthic Macroinverlebrate 6

16 Fish

.6 8

16 11 Corbicula and Zebra Mussel 14 16 6

19 8

19 16 24 II Corbicula CT Density 14*

16 6

19 8

19 16 24 11 Zebra Mussel Veliger 14 16 6

19 8

19 16 24 11

TABLE 5.2 SYSTEMATIC LIST OF MACROINVERTEBRATES COLLECTED FROM 1973 THROUGH 2003 IN THE OHIO RIVER NEAR BVPS Collected in Collected in New in Taxa Previous Years 2003 2003 Porifera Spongilla fragilis X

Cnidaria Hydrozoa Clavidae Cordylophora lacustris X

Hydridae Craspedacusta sowerbii X

Hydra sp.

X Platyhelminthes Tricladida x

Rhabdocoela X

Nemertea x

Nematoda X

X Entoprocta Urnatella gracilis X

Ectoprocta Fredericella sp.

X Paludicella articulata X

Pectinatella sp.

X Plumatella sp.

X Annelida Oligochaeta X

X Aeolosomatidae X

Tubificida X

Enchytraeidae x

Naididae X

Allonais pectinata X

Amphichaeta leydigi X

Amphichaeta sp.

X Arcteonais lomondi X

Aulophorus sp.

X Chaetogaster diaphanus X

C. diastrophus X

Dero digitata X

Dero flabelfiger X

D. nivea X

Dero sp.

X Nais barbata X

N. behningi X

N. bretscheri X

N. communis X

X N. elinguis X

X N. pardalis X

N. pseudobtusa X

TABLE 5.2 (Cont'd)

Collected in Collected in New in Taxa Previous Years 2003 2003 N. simplex X

N. variabilis X

Nais sp.

X Ophidonais serpentina X

Paranais frici X

Paranais litoralis X

Paranais sp.

X Piguetiella michiganensis X

Pristina idrensis X

Pristina longisoma X

Pristina longiseta X

P. osbomi X

P. sima X

Pristina sp.

X X

Pristinella sp.

PristinellaJenkinae X

Pristinella idrensis Pristinella osborni X

Ripistes parasita X

Slavina appendiculata X

X Specanajosinae Stephensoniana trivandrana X

Stylaria fossularis X

S. Iacustris X

X Uncinais uncinata X

Veidovskyella comata X

Vejdovskyella intermedia X

Vejdovskyella sp.

X Tubificidae X

X Aulodrilus limnobius X

A. pigueti X

A. plunseta X

Aulodrilus sp.

X Bothrioneurum vejdovskyanum X

Branchiura sowerbyi X

X 11yodrilus templeton!

X Limnodrilus cervix X

L. cervix (variant)

X L. claparedianus X

L. hoffmeisteri X

X L. maumeensis X

X L. profundicla X

L. spiralis X

L. udekemianus X

Limnodrilus sp.

X Peloscolex multisetosus longidentus X

P. m. multisetosus X

Potamothrix moldaviensis X

Potamothrix sp.

P. veidovskyi X

X Psammoryctides curvisetosus X

Tubifex tubifex X

Unidentified immature forms:

X with hair chaetae X

without hair chaetae X

X

I I TABLE 5.2 (Cont'd)

Collected in Collected in New in Taxa Previous Years 2003 2003 Lumbriculidae X

X Hirudinae X

X Glossiphoniidae X

X Helobdella elongata X

H. stagnalis X

Helobdella sp.

X Erpobdellidae Erpobdella sp.

X Mooreobdella microstoma X

Haplotaxidae Stylodrilus heringianus X

Lumbricina X

Lumbricidae X

Arthropoda Acarina X

Ostracoda X

Isopoda Asellus sp.

X X

Amphipoda Talitridae Hyalella azteca X

Gammaridae Crangonyx pseudogracilis X

Crangonyx sp.

X Gammarus fasciatus X

Gammarus sp.

X X

Pontoporeiidae Monoporeia afftnis X

Decapoda X

Collembola X

Ephemeroptera Heptageniidae X

Stenacron sp.

X Stenonema sp.

X Ephemeridae Ephemera sp.

X Hexagenia sp.

X X

Ephron sp.

X Baetidae X

Baetis sp.

Caenidae Caenis sp.

X X

Serattella sp.

X Potamanthidae Potamanthus sp.

Tricorythidae Tricorythodes sp.

X Megaloptera Sialis sp.

X Odonata

-,:-TABLE 5.2 (Cont'd)

Collected In Collected in New In Taxa Previous Years 2003 2003 Gomphidae Argia sp.-

X Dromogomphus spoliatus X

Dromogomphus sp.

X X

Gomphus sp.

X X

Libellulidae Libellula sp.

X Trichoptera X

X Hydropsychidae X

Cheumatopsyche sp.

X Hydropsyche sp.

X Parapsyche sp.

X Psychomyiidae Psychomyia sp.

Hydroptilidae Hydroptila sp.

X Othotrichia sp.

Oxyethira sp.

X Leptoceridae Ceraclea sp.

X Leptocerus sp.

X Oecetis sp.

X Polycentropodidae Cymellus sp.

X Polycentropus sp.

X Coleoptera X

Hydrophilidae X

Elmidae X

Ancyronyx variegatus X

Dubiraphia sp.

X Helichus sp. -

X Stenelmis sp.

X Psephenidae X

Diptera Unidentified Diptera X

Probezzia X

Psychodidae X

Pericoma sp.

X Psychoda sp.

X Telmatoscopus sp.

X Unidentified Psychodidae pupae X

Chaoboridae Chaoborus sp.

X Simuliidae Similium sp.

X Chironomidae X

Chironominae X

X Tanytarsini pupa X

Chironominae pupa X

Axarus sp.

X X

Chironomus sp.

X X

Cladopelma sp.

X

I TABLE 5.2 (Cont'd)

Collected in Collected in New in Taxa Previous Years 2003 2003 Cladotanytarsus sp.

X Cryptochironomus sp.

X x

Dicrotendipes nervosus X

Dicrotendipes sp.

X Glyptotendipes sp.

X Hamischia sp.

X Microchironomus sp.

X Micropsectra sp.

X X

Microtendipes sp.

X Parachironomus sp.

X Paracladopelma sp.

X Paratanytarsus sp.

X Paratendipes albimanus X

X Phaenopsectra sp.

X X

Polypedilum (s.s.) convictum type X

P. (s.s.) simulans type X

Polypedilum sp.

X X

Rheotanytarsus sp.

X X

Stenochironomus sp.

X Stictochironomus sp.

X Tanytarsus coffmani X

Tanytarsus sp.

X X

Tribelos sp.

X Xenochironomus sp.

X Tanypodinae X

Tanypodinae pupae X

Ablabesmyla sp.

X X

Clinotanypus sp.

X X

Coelotanypus scapularis X

Coelotanypus sp.

X X

Djalmabatista pulcher X

Djalmabatista sp.

X Procladius sp.

X X

Tanypus sp.

X Thienemannimyla group X

Zavrelimyia sp.

X Orthocladiinae X

Orthocladiinae pupae X

Cricotopus bicinctus X

C. (s.s.) trifascia X

Cricotopus (Isocladius)-

-sylvestris Group X

X C. (Isocladius) sp.

x Cricotopus (s.s.) sp.

X X

Eukiefferiella sp.

X Hydrobaenus sp.

X Limnophyes sp.

X Nanocladius (s.s.) distinctus X

Nanocladius sp.

X Orthocladius sp.

X Parametriocnemus sp.

X Paraphaenocladius sp.

X Psectrocladius sp.

X Psectrotanypus sp.

Pseudorthocladius sp.

X

T. ABLE 5.2 (Cont'd)

Collected in' Collected in New in Taxa Previous Years 2003 2003 Pseudosmittia sp.

X Smittia sp.

X Theinemannimyia sp.

x.

Diamesinae Diamesa sp.

X Potthastia sp.

X Ceratopogonidae X

X Bezzia sp.

X Culicoides sp.

X X

Dolichopodidae X

Empididae x

Clinocera sp.

X Wiedemannia sp.

X Ephydridae x

Muscidae X

Umnphora sp.

Rhagionidae X

Tipulidae X

Stratiomyidae X

Syrphidae X

Lepidoptera X

Hydrachnidia X

X Mollusca Gastropoda X

Hydrobiidae X

Amnicolinae Amnicola sp.

X X

Amnicola limosa X

X Physacea X

Pleuroceridae x

Physidae X

Physa sp.

X Physa ancillaria Ancylidae x

Ferrissia sp.

X Planorbidae X

Valvatidae X

Valvata perdepressa X

Valvata piscinalis X

X Valvata sincera sincere X

X Valvata sp.

Pelecypoda x

Sphaeriacea X

Corbiculidae Corbicula fluminea x

x Corbicula sp.

x Sphaeriidae X

Pisidium ventricosum x

Pisidium sp.

X X

Sphaerium sp.

X

-LI I

TABLE 5.2 (Cont'd)

Collected in Previous Years Taxa Collected in 2003 New in 2003 Unidentified immature Sphaeriidae Dreissenidae Dreissena polymorpha Unionidae Anodonta grandis Anodonta (immature)

Elliptio sp.

Unidentified immature Unionidae x

x x

x x

x x

TABLE 5.3.1

- 7 BENTHIC MACROINVERTEBRATE COUNTS FOR TRIPLICATE SAMPLES TAKEN AT EACH SAMPLE STATION FOR MAY 2003 I

May Scientific name Location 2

May I

1I 2A 2

61 2B2 2B3 3

Total Nematoda Oligochaeta Nals communis N. elinguis Paranais litorafts Pristina sp.

Pristinella osboml Slavina appendiculatb Stylarla lacustris Branchiura sowerbyi Umnodnius hoffmeisted L maumeensls Potamobtrix Sp.

Tubificidae Tubificidae without hair chaetae Umnodrilus maumeensis Potamothrix vejdovskyi Lumbriculidae Hirundinea Glossiphoniidae Isopoda Gammarus Sp.

Stenonema sp.

Hexagenla sp.

Caenis Sp.

Ormogomphus sp.

Gomphus sp.

TrIchoptera Elmidae Chironidae Chironominae Axanus sp.

Chironomus sp.

Cladotanytarsus sp.

Cryptochironomus sp.

Dicrotendkpes sp.

Micmpsectra Sp.

Paratendipes sp.

Phaenopsectra sp.

Polypedclum sp.

Rheotanytarsus sp.

Tanytarsus sp.

Ablabosmyia sp.

Clinotanypus sp.

Coelotanypus sp.

Procladius sp.

Tanypus sp.

Cricotopus (s.s sp.

Cricotopuw (isocladius) sp.

Ceratopogonidae Curicoides sp.

Hydracarina.

Amnnicola sp Amnicola 6lmosa Pleuroceddae sp.

Vahvataplscinalis Vahtah sincera sincera Corbicula lluminea Pisicdum sp.

3 17

1 4

17 1

13 I

1 1

1 2

1 3

1 6

54 1

1 1

7 7

1 3~4

.92 169 2

2 67 39 1

1 1

1 2

1 I

15 1

1 1

2 2

2 1

7 1

so 1

2 0*

51 2

20 0

0.

1 455 2

2 2

1' 0-0 4

0-16 2.

0 1'

2 4.

0 3

0 94 1,

19o

'1 2

2 570 4'

7-

.0 0:

10 0

8 6.

3

,1

-0*

0 5

1 0

0.

1 31 2

5 59 23 1

3 1

7 1

I 2

5 2

5 2

127 164 I

I 2

228 2

9 9

1 1

4 33 1

1 I9 2

6 6

1 1;

.3 I

1 1

7 12 8

3 Monthly Total 165 l

306 l

520 l

143 l 105 l

112 1351 k

LI TABLE 5.3.2 BENTHIC MACROINVERTEBRATE COUNTS FOR TRIPLICATE SAMPLES TAKEN AT EACH SAMPLE STATION FOR SEPTEMBER 2003 September Scientific name J

Location September 2003 1

2A 2B1 2B2 2B3 3

Total Total 4

4 Nematoda Oligochaeta Nais communis N. efinguis Paranais 6itoralis Pristina sp.

Pristinella osborni Slavina appendiculata Stylaria lacustnis Branchiura sowerbyi Limnodndus hoffmeisted L. maumeensis Potamothrix sp.

Potamothrix vejdovskyi Tubificidae Tubificidae without hair chaetae Limnodrilus maumeensis Potamothlix vejdovskyi Lumbriculidae Hirundinea Glossiphoniidae Isopoda Gammarus sp.

Stenonema sp.

Hexagenia sp.

Caenis sp.

Dromogomphus sp.

Gomphus sp.

Trichoptera Elmidae Chironidae Chironominae Axarus sp.

Chironomus sp.

Cladotanytarsus sp.

Cryptochironomus sp.

Dicrotendipes sp.

Micropsectra sp.

Paratendipes sp.

Phaenopsectra sp.

Polypedllum sp.

Rheotanytarsus sp.

Tanytarsus sp.

Ablabesmyia sp.

Chnotanypus sp.

Coelotanypus sp.

Procladius sp.

Tanypus sp.

Cricotopus (s.s) sp.

Cdcotopus (Isocladius) sp.

Ceratopogonidae Curicoides sp.

Hydracarina Amnicola sp.

Amnicola limosa Pleuroceridae sp.

Valvata piscinals V. sincera sincera Corbicula fluminea Pisidium sp.

I 1

1 2

I 2

1 4

1 2

3 3

2 13 9

9 3

20 4

34 36 64 7

2 3

1 5

15 1

4 5

3 3

4 1

3 3

2 1

0 0

O 8

1 0

5 19 9

0 12 0

165 0

0 0

0 2

24 1

6 11 1

0 8

0 1

0 4

1 0

23 0

0 0

0 61 0

16 1

2 7

2 0

0 0

0 0

2 3

0 7

2 2

178 10 3

51 1

1 1

19 9

O 13 620 2

11 2

28 1

2 13 1

2 10 1

2 4

95 1

42 0

1 2

2 631 4

23 1

2 7

12 0

8 6

23 1

2 3

6 7

2 3

209 1

4 2

I 1

4 8

4 4

4 4

37 12 4

2 1

8 1

2 7

2 1

4 3

I 1

1 1

2 5

8 5

2 29 105 3

28

+

Monthly Total 51 l

29 1 132 1 200 I119 1

61 592 1 921 Monthly Total 51 I

29 I

132 I 200 I

119 I 61 592 1921

TABLE 5.4 MEAN NUMBER OF MACROINVERTEBRATES (NUMBERIM 2) AND PERCENT COMPOSITION OF OLIGOCHAETA, CHIRONOMIDAE, MOLLUSCA, AND OTHER ORGANISMS, 2003 BVPS May 6 Station I (Control) 2A 2B1 (Non-control) l2B2 (Non-control) 12B3 (Non-control)

  1. /M2 __

I

  1. /m 2 l
  1. /m 2
  1. Im 2
  1. /m 2
  1. 1r 2 Oligochaeta 1462 21 5203 40 8385 38 3655 62 1806 44

-2924 61 Chironomidae 5590 79 7439 57 13158 59 1548 26 989 24 1634 34 Mollusca 0

0 129 1

344 2

516 9

473 11 172 4

Others 43 1

258 2

301 1

215 4,

860 21

.86 2

Total 7095 100 13029 100 22188 100 5934 100 4128 100 4816 100 September 16 Station 1 (Control) 2A 2B1 (Non-control) l2B2'(Non-control) 2B3 (Non-control) 3

  1. Ilm 2
  1. /m 2
  1. I/M2 I
  1. /m 2 W

I

  1. /m 2 l/m2.

Oligochaeta 1118 51 301 24 2236 39 1548 18' 3913 76 430 16 Chironomidae 387 18 387 31 1849 33 1204 14 688 13 559 21 Mollusca 258 12 473 38 1247 22 4816 56 172 3

1333 51 Others 430 20 86 7

344 6

1032 12 344 7

301 11 Total 2193 100 1247 100 5676 100 8600 100 5117 100 2623 100

I I TABLE 5.5 MEAN NUMBER OF MACROINVERTEBRATES (NUMBER/M 2) AND PERCENT COMPOSITION OF OLIGOCHAETA, CHIRONOMIDAE, MOLLUSCA, AND OTHER ORGANISMS FOR THE CONTROL STATION (1) AND THE AVERAGE FOR NON-CONTROL STATIONS (22B1, 2B2, AND 2B3), 2003 BVPS May 6 Control Station (Mean)

Non-Control Station (Mean)

  1. 1m 2
  1. /m 2

(

Oligochaeta 1462 21 4615 43 Chironomidae 5590 79 5232 49 Mollusca 0

0 444 4

Others 43 1

459 4

TOTAL 7095 100 10750 100 September 16 I Control Station (Mean)

N Non-Control Station (Mean)

  1. /m 2
  1. /m 2 Oligochaeta 1118 51 2566 40 Chironomidae 387 18 1247 19 Mollusca 258 12 2078 32 Others 430 20 573 9

TOTAL 2193 100 6464 100

- TABLE 5.6 SHANNON-WEINER DIVERSITY, EVENNESS AND RICHNESS INDICES FOR BENTHIC MACROINVERTEBRATES COLLECTED IN THE OHIO RIVER, 2003 Station Date: May 6 1

2A 261 282 2B3 3

No. of Taxa 4

19 17 21 15 15i Shannon-Weiner Index 0.27 0.57 -

0.62 0.66 0.79 0.63 Evenness-0.46 0.45 0.51 0.50 0.67 0.54 Richness 0.59 3.15 2.56 4.10 3.06 2.98 Station Date: September 19 1

2A 2B1 2B2 2B3 3

No. of Taxa 15 11 15 13 14 12 Shannon-Weiner Index 0.94 0.92 0.83 0.70 0.76 0.83 Evenness 0.80 0.89 0.70 0.63 0.66 0.76 Richness 3.03 2.46 2.51 2.00 2.38 2.29

TABLE 5.7 BENTHIC MACROINVERTEBRATE DENSITIES (NUMBER/M 2) FOR STATION 1 (CONTROL) AND STATION 2B (NON-CONTROL) DURING PREOPERATIONAL AND OPERATIONAL YEARS THROUGH 2003 BVPS Month Preoperational Years Operational Years 1973 1974 1975 1976 1977 1978 1

l 2B I

l 2B I

l 2B 1

2B I

2B I

2B 248 508 1,116 2,197 927 3l0 927 674 848 351 T 126 August 99 244 143 541 1,017 1,124 851 785 591 3,474 601 1 1,896 Mean 173 376 630 1,369 1,017 1124 889 2,223 633 2,161 476 Month Operational Years l

I 1979 1980 1981 1982 1983 1984 1

2B I

2B 1

2B I

2B

[

1 2B I 1 l

2B May 1,004 840 1,041 747 209 456 3,490 3,026 3,590 l 1314 l2741 621 August 1,185 588 l l

ll l

September I

1,523 448 2,185 l 912 l 2,958 l 3,364 l 4,172 l

4,213 1,341 828 Mean 1,095 714 1,282 598 1,197 684 3,223 3,195 3,881 2,764 2,041 725

TABLE 5.7 (Cont'd)

BENTHIC MACROINVERTEBRATE DENSITIES (NUMBERIM 2) FOR STATION I (CONTROL) AND STATION 2B (NON-CONTROL) DURING PREOPERATIONAL AND OPERATIONAL YEARS THROUGH 2003 BVPS Month

~~O perational Y ears_

1985 1986 1987 1988 1989 1990 1 j283 I

1 1

J23 I

J B~

i I

I J28 J

21 M

-a I 2 85 67 601 969 1 971 2,64 11804 1,7 3,45 2,3 15,135 579 September 1,024 913.

849' 943 2,1

,8 142 1.51 1,560 4.707 5,550 1,118 Ma j 1,4j 890 75 96 2.440 2,71 J1.612 1,65 12.510 3,274 110,343 3,457 M onth Operational Years 1991 1992 1993 1994 J

1995 1996 13 I

2B3 I

23 I

1261 1I 26 JI 128 S§eptmbe~r 3,85 1 2,605

,93 213

.1.1371, 2,930 1 1,669 1 3,873 1 1,649 2,413J Mean

!5,80814,48015,019,

7,634 6,564 2:,14:81 4,176 J2,64:01 4,876 6,578 1,814 1,873]

-Mvean oT /Ei W2 2ba3 I

I I

TABLE 5.7 (Cont'd)

BENTHIC MACROINVERTEBRATE DENSITIES (NUMBER/M 2) FOR STATION 1 (CONTROL) AND STATION 2B (NON-CONTROL) DURING PREOPERATIONAL AND OPERATIONAL YEARS THROUGH 2003 BVPS Month Operational Years 1997 1998 1999 2000

[

1 2B* J I

2B 1

l 2B*

I 2B*

May 1,411 2,520 6,980 2,349 879 1,002 2,987 2,881 September 1,944 2,774 1,371 2,930 302 402 3,092 2,742 Mean 1,678 2,647 1 4,176 l

2,640 l

591 l

702 l 3,040 l 2,812

  • Mean of 2B1, 282, 283 I

Month Operational Years 2001 2002 2003 1.l 2B=1J 28' I

113*

I 2B*

May 3,139 5,232 1,548 2,795 7,095 10,750 September 1

8,632 14,663 2,193 6,464 Mean 3,139 5,232 J5,090 8,729 {4,644 j 8,607

  • Mean of 281, 282,283

TABLE 5.8 i

.~

SCIENTIFIC AND COMMON NAME1 OF FISH COLLECTED IN THE NEW CUMBERLAND POOL OF THE OHIO RIVER, 1970 THROUGH 2003 I. - BVPS Page 1 of 3 Family and Scientific Name Lepisosteidae (gars)

Lepisosteus osseus Hiodontidae (mooneyes)

Hiodon alosoides H. tergisus Clupeidae (herrings)

Alosa chrysochloris A. pseudoharenqus Dorosoma cepedianum Common Name Longnose gar Goldeye Mooneye

-' Skipjack herring

'Alewife

-Gizzard shad Cyprinidae (carps and minnows)

Campostoma anomalum Carassius auratus Ctenopharynpodon idella Cvprinella spiloptera Cvyrinus caroio C. caggi x C. auratus Luxilus chrysocephalus Macrhybopsis storeriana Nocomis micropopon Notemiponus crvsoleucas NotroDis atherinoides N. buccatus N. hudsonius N. rubellus N. stramineus N. volucellus Pimephales notatus P. promelas Rhinichthys atratulus Semotilus atromaculatus

'Central stoneroller Goldfish Grass carp Spotfin shiner Common carp Carp-goldfish hybrid Striped shiner Silver chub River chub Golden shiner Emerald shiner Silverjaw minnow Spottail shiner Rosyface shiner

-Sand shiner Mimic shiner Bluntnose minnow Fathead minnow Blacknose dace Creek chub Catostomidae (suckers)

Carpiodes carnio C. cyprinus C. velifer Catostomus commersoni Hypentelium niaricans Ictiobus bubalus

1. niqer Minvtrema melanons

-River carpsucker Quillback Highfin carpsucker White sucker Northern hogsucker

-Smallmouth buffalo Black buffalo Spotted sucker

II TABLE 5.8 (Continued)

Page 2 of 3 Family and Scientific Name Common Name Moxostoma anisurum M. carinatum M. duquesnei M. ervthrurum M. macroleDidotum Ictaluridae (bullhead catfishes)

Ameiurus catus A. furcatus A. melas A. natalis A. nebulosus Ictalurus ounctatus Noturus flavus Pylodictis olivaris Esocidae (pikes)

Esox lucius E. masQuinonpy E. lucius x E. masquinonpy Salmonidae (trouts)

Oncorhynchus mykiss Percopsidae (trout-perches)

Percopsis omiscomavcus Cyprinodontidae (killifishes)

Fundulus diaohanus Silver redhorse River redhorse Black redhorse Golden redhorse Shorthead redhorse White catfish Blue catfish Black bullhead Yellow bullhead Brown bullhead Channel catfish Stonecat Flathead catfish Northern pike Muskellunge Tiger muskellunge Rainbow trout Trout-perch Banded killifish Atherinidae (silversides)

Labidesthes sicculus Percichthyidae (temperate basses)

Morone chrvsops M. saxatilis M. saxatilis x M. chrvsops Centrarchidae (sunfishes)

Ambloplites rupestris Lepomis cvanellus L. qibbosus L. macrochirus L. microlophus L. nibbosus x L. microlophus Micropterus dolomieu M. punctulatus M. salmoides Pomoxis annularis P. nicromaculatus Brook silverside White bass Striped bass Striped bass hybrid Rock bass Green sunfish Pumpkinseed Bluegill Redear sunfish Pumpkinseed-redear sunfish hybrid Smallmouth bass Spotted bass Largemouth bass White crappie Black crappie

TABLE 5.8 (Continued)

Page 3of3 Familv and Scientific Name Percidae (perches)

Etheostoma blennioides E. niprum E. zonale Perca flavescens Percina caprodes P. copelandi Stizostedion canadense S. vitreum S. canadense x S. vitreum Sciaenidae (drums)

Aplodinotus prunniens Common Name Greenside darter Johnny darter Banded darter Yellow perch Logperch Channel darter Sauger-Walleye Saugeye Freshwater drum Nomenclature follows Robins, et ai. (1991)

A,

TABLE 5.9 COMPARISON OF CONTROL VS. NON-CONTROL ELECTROFISHING CATCHES DURING THE BVPS 2003 FISHERIES SURVEY Common Name Scientific Name l Control Non-control l % l Total fish l % l Black buffalo Ictiobus niger 1

1.8 16 10.3 17 8.1 Black crappie Pomoxis nigromaculatus 1

1.8 1

0.5 Blue catfish Ictalurus furcatus 1

0.6 1

0.5 Bluegill Lepomis macrochirus 1

1.8 1

0.6 2

0.9 Channel catfish Ictalurus punctatus 2

1.3 2

0.9 Common carp Cypnnus carpio 2

1.3 2

0.9 Silver chub Macrhybopsis storeriana 1

0.6 1

0.5 Emerald shiner Notropis atherinoides 1

0.6 1

0.5 Flathead catfish Pylodictus olivaris 1

0.6 1

0.5 Freshwater drum Aplodinotus grunniens 1

1.8 15 9.6 16 7.6 Gizzard shad Dorosoma cepedianum 1

1.8 13 8.3 14 6.6 Golden redhorse Moxostoma erythrurum 8

14.5 16 10.3 24 11.4 Northern hog sucker Hypentelium nigncans 1

0.6 1

0.5 Longnose gar Lepisosteus osseus 6

3.8 6

2.8 Mooneye Hiodon tergisus 4

2.6 4

1.9 Quillback Carpiodes cyprinus 1

1.8 9

5.8 10 4.7 Sauger Stizostedion canadense 9

16.4 16 10.3 25 11.8 Shorthead redhorse sucker Moxostoma macrolepidotum 16 29.1 25 16.0 41 19.4 Silver redhorse Moxostoma anisurum 3

5.5 9

5.8 12 5.7 Rock bass Ambloplites rupestris 1

0.6 1

0.5 Smallmouth bass Micropterus dolomieu 1

1.8 8

5.1 9

4.3 Spotted bass Micropterus punctulatus 3

1.9 3

1.4 Striped bass hybrid Morone saxatilis x Morone chrysops 11 20.0 11 5.2 Walleye Stizostedion vitreum 1

1.8 1

0.6 2

0.9 White bass Morone chrysops 3

1.9 3

1.4 White catfish Ameriurus catus 1

0.6 1

0.5 Electrofishing Gear Total:

55 100 156 l100 l 211 11001

TABLE 5.10 COMPARISON OF CONTROL VS. NON-CONTROL SEINE CATCHES

- DURING THE BVPS 2003 FISHERIES SURVEY Common Name ScientificName Control l

lNon-control l l Total fish I

Bluntnose minnow Pimephales notatus 2

5.4 0.0 2

4.91 Ermerald shiner Notbopis -the rinoides

1 2.7 2

50.0 3

i.3 Freshwater drum Aplodinotus grunniens 1

25.0 1

2.4 Spottail shiner Notropis hudsonius 34 91.9 1

25.0 35 85.4 Seine Gear Total:

37 -

100 l

4 100 41 100 Seine and 1

{

i l

Electrofishing l

Year Total

.92_

160 2

l 252 l

TABLE 5.11 FISH SPECIES COLLECTED DURING TIlE MAY 2003 SAMPLING OF TIIE OHIO RIVER IN THE VICINITY OF BVPS Sample locations

  • Seine Electrofishing Common Name Scientific Name ISS-l*S-2**] E-1 [ E-2A I E-2B 1 E-3 Total I % [Total I Black Buffalo Ictiobus niger 2

0 0.0 2

4.7 Bluntnose minnow Pimephales notatus 2

2 5.4 0

0.0 Common carp Cypinus carpio I

0 0.0 1

2.3 Emerald shiner Notropis atherinoides I

0 0.0 1

2.3 Gizzard shad Dorosoma cepedianum 3

2 1

0 0.0 6

14.0 Golden redhorse Moxostoma erythrurum 2

1 3

3 0

0.0 9

20.9 Mooneye Hiodon tergisus 1

0 0.0 1

2.3 Northern hogsucker Hypentelium nigricans 1

0 0.0 1

2.3 Quillback Carpiodes cyprinus 1

2 0

0.0 3

7.0 Shorthead redhorse sucker Moxostoma macrolepidotum 2

1 0

0.0 3

7.0 Silver rcdhorse Moxostoma anisurum 1

3 0

0.0 4

9.3 Smallmouth bass Micropterus dolomieu 1

2 0

0.0 3

7.0 Spottail shiner Notropis hudsonius 34 1

35 94.6 0

0.0 Stripcd bass hybrid Morone saxatilis x Morone chrysops 8

0 0.0 8

18.6 White bass Morone chrysops I_

1 n

n Q 1

9 L

lTotal 36 I

7 l_8 l 17 l 37 l 1l0o0 43 l00]

  • Gear = (E) Fish captured by electrofishing; (S) captured by seining
    • Seine netting could not be safely done because of high river water conditions

TABLE 5.12

-FISH SPECIES COLLECTED DURING THE JULY 2003 SAMPLING

-.OF THE OHIO RIER IN THE VICINITY OF BVPS Sample locations

  • Seine Electrofishing Common Name

.Scientific Name

.S-1

.S-2 l E-l l.E-2A E-2B E-3 Total Total l_%

Black buffalo Ictiobus niger 1

1 0

0.0 3

6.0 Bluegill Lepomis macrochirus 1

1 0

0.0 2

4.0 Channel catfish Ictalurus punctatus.

.1 0

0.0 2

4.0 Emerald shiner Notropis atherinoides.,

1 2

. 66.7 0

0.0 Freshwater drum Aplodinotus grunniens 1

I 33.3 0

0.0 Longnose gar Lepisosteus osseus.

0' 0.0 I

2.0 Quillback Carpiodes cyprinus 0

. 0.0 1

2.0 Siauger Stizostedion canadense 5

2 2

2 0

0.0 I 1 22.0 Shorthead redhorse sucker Moxostoma macrolepidotumr 4

6 4

0 0.0 14 28.0 Silver redhorse Moxostoma anisuntm 2

1 1

0 0.0 4

8.0 Smallmouth bass Micropterus dolomieu 1

4 I

0 0.0 6

12.0 Spotted bass Micropterus punctulatus 3

0 0.0 3

6.0 Striped bass hybrid Morone saxatilis x Morone chrysops 0

0.0 1

2.0 Walleye Stizostedion vitreum 1

0 0.0 1

2.0 White bass Morone chyrsops I

1 0

0.0 1

2.0 ffotal 1 1 1 2 1141 21 1

4 1 1 3

1o100 o50 100

  • Gear = (E) Fish captured by electrofishing; (S) captured by seining

TABLE 5.13 FISH SPECIES COLLECTED DURING THE SEPTEMBER 2003 SAMPLING OF TIIE OHIO RIVER IN THE VICINITY OF BVPS Sample locations

  • Seine Electrofishing comon Narne lScientific Name l S-l S-2 E-l E-2A E-2B E-3 Total l Totall Black buffalo Ictiobus niger 1

4 0

0.0 5

16.1 Black crappie Pomoxis nigromaculatus I

0 0.0 1

3.2 Flathead catfish Pylodictus olivaris I

0 0.0 1

3.2 Freshwater drum Aplodinotus grunniens I

0 0.0 1

3.2 Gizzard shad Dorosoma cepedianum 1

2 2

0 0.0 5

16.1 Longnose gar Lepisosteus osseus 2

1 0

0.0 3

9.7 Quillback Carpiodes cyprinus 1

I 0

0.0 2

6.5 Sauger Stizostedion canadense 3

0 0.0 3

9.7 Silver redhorse Moxostoma anisurum I

0 0.0 1

3.2 Shorthead redhorse sucker Moxostoma macrolepidotum 2

5 0

0.0 7

22.6 White bass Morone chrysops 1

0 0.0 1

3.2 White catfish Ameriurus catus 1

0 0.0 1

3.2 ITotal OI l 0

4 1

16 l

4 l

7 l

0 0

3 1 100

  • Gcar = (E) Fish captured by electrofishing; (S) captured by seining L

TABLE 5.14 FISH SPECIES COLLECTED DURING THE NOVEMBER 2003 SAMPLING OF THE OHIO RIVER IN THE VICINITY OF BVPS Sample locations

  • Seine Electrofishing lCommon Name IScientific Name S-1 S-2 E-1 l E-2A l E-2B l E-3 Total l%

Total I Black buffalo Ictiobus niger 7

0 0.0 7

8.0 Blue catfish Ictalurusfurcatus I

0 0.0 1

1.1 Common carp Cyprinus carpio I

0 0.0 1

1.1 Emerald shiner Notropis atherinoides 1

I 100.0 0

0.0 Freshwater drum Aplodinotus grunniens 1

6 6

2 0

0.0:,

-15 17.2 Gizzard shad Dorosoma cepedianum I

I 1'

0 0.0 3 -

3.4 Golden redhorse Moxostoma erythrurum 6

8 1

0 0.0 15 17.2 Longnose gar Lepisostets osseus 2

0 0

0.0 2

2.3 Mooneye Hiodon tergisus 2

1 0

0.0 3

3.4 Quillback Carpiodes cyprinus 1

3 0-0.0 4

4.6 Rock bass Ambloplites nrpestris I

0 0.0 I

1.1 Sauger Stizostedion canadense 4

1 4

2 0

0.0 11 12.6 Silver chub Macrhybopsis storeriana I

0 0.0 I

1.1 Silver redhorse Moxostoma anisurum 3

0 0.0 3

3.4 Shorthead redhorse sucker Moxostoma macrolepidotum 10 2

5 0

0.0 17 19.5 Spottail shiner Notropis hudsonius 0

0.0 0

0.0 Striped bass hybrid Morone saxatilis x Morone chrysops 2

0 0.0 2

2.3 Walleye Stizostedion vitreum I

0 0.0 1

1.1 Total O

1 26 21 26 1411 100 87 l

100

  • Gear = (E) Fish captured by electrofishing; (S) captured by seining

II TABLE 5.15 ESTIMATED NUMBER OF FISH OBSERVED

  • DURING ELECTROFISHING OPERATIONS Common Name Scientific Name May July Sept Nov Total Emerald shiner Notropis atherinoides I 00's 100's Gizzard shad Dorosoma cepedianum lI GLongnose gar Lepisosteus osseusan 1I 1

Total l

1 I 1 00's [

1 I

0 l

1 00's

  • = Not boated or handled

Table 5.16 CATCH PER UNIT EFFORT (CPUE AS FISH/ELECTROFISHING MINUTE)

BY SEASON DURING THE BVPS 2001 FISHERIES SURVEY Season Effort (min) Common Name Count of species CPUE (fish/min)

Spring 40 Channel catfish 2

0.050 Freshwater drum 2

0.050 Gizzard shad 14 0.350 Golden redhorse 17 0.425 Quillback 1

0.025 River carp sucker 3

0.075 Sauger 2

0.050 Shorthead redhorse sucker 10 0.250 Silver redhorse 7

0:175 Smallmouth bass 5

0.125 Smallmouth buffalo 4

0.100 Walleve 1

0.025

l

.X Season Total 68 1.700

.l Season:l Effort(m)

CommonName Countofspecies l ECPIE(fishlmin)

Summer 40 Black buffalo 2

0.0500 Bluegill 2

0.0500 Common carp 1

0.0250 Emerald shiner 2

0.0500 Flathead catfish 2

0.0500 Freshwater drum 2

0.0500 Golden redhorse 6

0.1500 Sauger 8

0.2000 Shorthead redhorse sucker 2

0.0500 Silver redhorse 3

0.0750 Smallmouth bass -

3 0.0750

._.,,_._Spotted bass 1

0.0250 l I SeasonTotal

- l 34 0.8500 l

Year l

.80 102 1.2750= ]

I I Table 5.17 CATCH PER UNIT EFFORT (CPUE AS FISII/ELECTROFISHING MINUTE)

BY SEASON DURING THE BVPS 2002 FISHERIES SURVEY Season lEfort (min)

ICommon Name lNumber Collected1 CPUE (fish/min)

Spring 40.06 Channel catfish 6

0.1498 Common carp 1

0.0250 Flathead catfish 1

0.0250 Freshwater drum 15 0.3744 Gizzard shad 4

0.0999 Golden redhorse 4

0.0999 High fin carpsucker I 1 0.2746 Longnose gar 1

0.0250 Quillback 6

0.1498 Mooneye 2

0.0499 River redhorse 3

0.0749 Sauger 3

0.0749 Shorthead redhorse 6

0.1498 Silver redhorse I 1 0.2746 Walleye 2

0.0499 White bass 6

0.1498 Season Total 82 2.0469 Season Effort (min)

Common Name I

Number Collected1 CPUE (fish/min)

Surnmer 40 Black buffalo 1

0.0250 Common carp 2

0.0500 Freshwater drum 1

0.0250 Gizzard shad 4

0.1000 Golden redhorse 15 0.3750 Quillback 2

0.0500 Pumpkinseed 1

0.0250 Sauger 1

0.0250 Shorthead redhorse 1

0.0250 Silver redhorse 1

0.0250 Spottail shiner 4

0.1000 Spotted bass 4

0.1000 Walleye 3

0.0750 White bass 3

0.0750 ISeason Total J

43 1

1.0750

Table 5.18 CATCH PER UNIT EFFORT (CPUE AS FISH/ELECTROFISHING MINUTE)

BY SEASON DURING THE BVPS 2003 FISHERIES SURVEY FSeason J Effort (min) lCommon Name J

Number Collected1 CPUE (fish/rin)]

Spring 40.65 Buffalo sp.

2 0.0492 Common carp -

1 0.0246 Emerald shiner 1

0.0246 Gizzard shad 6

0.1476 Golden redhorse 9

0.2214 Mooneye 1

0.0246 Northern hogsucker 1

0.0246 Quillback 3

0.0738 Shorthead redhorse sucker 3

0.0738 Silver redhorse 4

0.0984 Srnallmouthbass 3

0.0738 Striped bass hybrid 8

0.1968 l

White bass 1

0.0246 I

. Season Total 43 1.0578

']

Season j Efort(min) JCommonName Number Collectedl CPUE (fish/rin)

Summer 43.43 Blackbuffalo 3

0.0691 Blue gill 2

0.0461 Channel catfish 2

0.0461 Longnose gar 1

0.0230 Quillback 1

0.0230 Sauger 11 0.2533 Shorthead redhorse sucker 14 0.3224 Silver redhorse 4

0.0921 Smallmouth bass 6

0.1382 Spotted bass 3

0.0691 Striped bass hybrid I

0.0230 Walleye

. 1 0.0230 White bass 1

0.0230 Season Total l

50 l

1.1513

I I Table 5.18 (Cont'd)

CATChI PER UNIT EFFORT (CPUE AS FISHI/ELECTROFISHING MINUTE)

BY SEASON DURING THE BVPS 2003 FISHERIES SURVEY Season Effort (mi)

Common Name I Number Collected1 CPUE (fish/min)

Fall 40.03 Black buffalo 5

0.1249 Black crappie 1

0.0250 Flathead catfish 1

0.0250 Freshwater drum 1

0.0250 Gizzard shad 5

0.1249 Longnose gar 3

0.0749 Quillback 2

0.0500 Sauger 3

0.0749 Silver redhorse 1

0.0250 Shorthead redhorse sucker 7

0.1749 White bass 1

0.0250 White catfish 1

0.0250 Season Total 31 0:0.7744 Season j Effort (min) lCommon Name JNumber Collected1 CPUE (fish/min) lWinter 41.00 Black buffalo 7

0.1707 Blue catfish 1

0.0244 Common carp 1

0.0244 Freshwater drum 15 0.3659 Gizzard shad 3

0.0732 Golden redhorse 15 0.3659 Longnose gar 2

0.0488 Mooneye 3

0.0732 Quillback 4

0.0976 Rock bass 1

0.0244 Sauger 11 0.2683 Shorthead redhorse sucker 17 0.4146 Silver chub 1

0.0244 Silver redhorse 3

0.0732 Spotted bass hybrid 2

0.0488 Walleve 1

0.0244 SeasonTotal 87 2.1220 Year 165.11 211 1.2779

TABLE 5.19

. UNIT 1 COOLING RESERVOIR MONTHLY SAMPLING CORBICULA DENSITY DATA FOR 2003 FROM BVPS Maximum Area Length Minimum Estimated Collection sampled Live or Range length number Date (sq ft)

Dead Count (mm)

Range(mm) (per sq m) 3/14/2003 0.25 Dead 0

Live 0

4/16/2003 0.25 Dead 0

Live 0

5/6/2003 0.25 Dead 18 4.75-6.29 0.01-0.99 774 Live 4

1.00-1.99 1.00-1.99 172 6/19/2003 0.25 Dead 5

0.01-0.99 0.01-0.99 215 Live 4

3.35-4.74 0.01-0.99 172 7/8/2003 0.25 Dead 5

2.00-3.34 0.01-0.99 215 Live 1

3.35-4.74 3.35-4.74 43 8/19/2003 0.25 Dead 8

2.00-3.34 0.01-0.99 344 Live 1

0.01-0.99 0.01-0.99 43 9/16/2003 0.25 Dead 2

4.75-6.29 2.00-3.34 86 Live 11 0.01-0.99 0.01-0.99 473 10/24/2003 0.25 Dead 6

1.00-1.99 0.01-0.99 258 l

Live 8

1.00-1.99 0.01-0.99 344 11/11/2003 0.25 Dead 1

1.00-1.99

-1.00-1.99 43 Live 12 1.00-1.99 1.00-1:99 516 Unit summary Dead 45 0.01-6.29 0.01-3.34 215 Live 41 0.01-4.74 0.01-4.74 196

  • Unit 2 on outage

LI TABLE 5.20 UNIT 2 COOLING RESERVOIR MONTHLY SANIPLING CORBICULA DENSITY DATA FOR 2003 FROM BVPS Maximum Area Length linimum Estimated Collection sampled Live or Range length number Date (sq ft)

Dead Count (mm)

Range(mm) (per sq m) 3/14/2003 0.25 Dead 1

1.00-1.99 1.00-1.99 43 Live 17 3.35-4.74 1.00-1.99 731 4/16/2003 0.25 Dead 8

1.00-1.99 1.00-1.99 344 Live 18 3.35-4.74 1.00-1.99 774 5/612003 0.25 Dead 0

0 Live 0

0 6/19/2003 0.25 Dead 49 3.35-4.74 0.01-0.99 2107 Live 0

0 7/8/2003 0.25 Dead 107 4.75-6.29 0.01-0.99 4601 Live 3

1.00-1.99 1.00-1.99 129 8/19/2003 0.25 Dead 73 3.35-4.74 0.01-0.99 3139 Live 0

0 9/16/2003 0.25 Dead Live 10/24/2003 0.25 Dead 0

0 Live 0

0 11/11/2003 0.25 Dead 0

0 Live 0

0 Unit summary Dead 238 1.00-6.29 0.01-1.99 1137 Live 38 1.00-4.74 1.00-1.99 182

  • Unit 1 on outage

Table 5. 20.1 ZEBRA MUSSEL MORTALITY DURING CLAMICIDE TREATMENTS, BVPS 2003.

Clamicide Treatment Start Date 25-Apr-03 02-May-03 07-May-03 06-Jun-03 16-Jul-03 22-Jul-03 07-Aug-03 14-Oct-03 22-Oct-03 28-Oct-03 04-Nov-03 Unit 2

2 2

1 2

1 2

1 2

I 2

Train B

B A

A B

B A

B A

A B

Water Temperature (degrees F) 57 63.2 64.6 63 72 72 N/A 58 55 53.5 53 Minimum 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> After Treatment Duration of Termination of Concentration 5.28 ppm 7.15 ppm 7.76 ppm 8.62 ppm 3.93 ppm 8.66 ppm 4.0ppm 5.24 ppm 4.0 ppm 5.87 ppm 8.6 ppm Inlection 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> 18 hours 18 hours2.083333e-4 days <br />0.005 hours <br />2.97619e-5 weeks <br />6.849e-6 months <br /> 18 hours 9 hours1.041667e-4 days <br />0.0025 hours <br />1.488095e-5 weeks <br />3.4245e-6 months <br /> 9 hours 9 hours1.041667e-4 days <br />0.0025 hours <br />1.488095e-5 weeks <br />3.4245e-6 months <br /> 18 hours 18 hours2.083333e-4 days <br />0.005 hours <br />2.97619e-5 weeks <br />6.849e-6 months <br /> 18 hours 18 hours2.083333e-4 days <br />0.005 hours <br />2.97619e-5 weeks <br />6.849e-6 months <br /> Treatment 100%

N/A 100%

N/A 100%

N/A 100%

N/A 85%

N/A 75%

48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> After 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> After 96 hours0.00111 days <br />0.0267 hours <br />1.587302e-4 weeks <br />3.6528e-5 months <br /> After Termination of Termination of Termination of Treatment Treatment Treatment N/A N/A N/A N/A N/A N/A N/A NIA N/A N/A N/A N/A NO DATA NO DATA 96%

N/A N/A N/A 78%

NO DATA NO DATA 120 hours0.00139 days <br />0.0333 hours <br />1.984127e-4 weeks <br />4.566e-5 months <br /> After 144 hours0.00167 days <br />0.04 hours <br />2.380952e-4 weeks <br />5.4792e-5 months <br /> After Termination of Termination of Treatment Treatment N/A N/A N/A N;A N/A N/A N/A N/A 66%

100%

N/A N/A 100%

1

II TABLE 5.21 ZEBRA MUSSEL SUBSTRATE SETTLEMENT RESULTS FROM BVPS, 2003 Substrate location/type Date set Date retrieved Number/m2 Barge Slip-Bridal Veil November 13, 2002 March 14 0

Barge Slip-Bridal Veil March 14 April 16 0

Barge Slip-Bridal Veil April 16 May 6 0

Barge Slip-Bridal Veil May 6 June 19 0

Barge Slip-Bridal Veil June 19 July 8 Barge Slip-Bridal Veil July 8 August 19 0

Barge Slip-Bridal Veil August 19 September 16 0

Barge Slip-Bridal Veil September 16 October 24 0

Barge Slip-Bridal Veil October 24 November 11 0

  • bridal veil was missing from collection device

FIGURES

I 0

2 Figure 5.1: Location Map for the Beaver Valley Power Station Aquatic Monitoring Program Control and Non-Control Sampling Locations

z 0

I Ml Figure 5.2: Location Map for the Beaver Valley Power Station Benthic Organism Sampling Sites

s

,Shlppingport Us; 14.0-no imn to 10 14 1997 Bceak1:31.250 aixcomesr)

.0 low MAW trDatn-Figure 5.3: Location Map for the Beaver Valley Power Station Fish Population Sampling Sites

-,.go a1 0

n CL Up m

0 0

ro UP 0

al:

OM wo z

rn z

M 0z m

0

-4

W D.

-J as W

W 0

IL E 0

z 550 -

I 450 -

400 -

350 -

300 -

250 -

200 -

150 -

100 -

50 -

I_

-i

-Tl 110 1-*

-I9u V.-

1

-Inc w

=I1 I

lfAi 1i1a1 V;fs'I.

sh.,.

t-I!ME i~ H MM,.

ri

%1'1.'

i il 1A h

MI 1=1

.X;,

,"i s' 4=s 1

7Ni,,I I

,J.

9%32.11fl

=1I

.1 M IN-1.

I-T

' 11l ;~WM-T'*M W

q-P&I Ial

- I g1 1g1 IX S I I ii n.

ii':s M



WN, 'MN

. tr=.~

MN

-~ M1l41 0 !.-

I I

S J,14- -

4/la I

6/19 7/S 6I 19 Wsn 7a"29 ttn 4"

a0n1-0.99 min 0

172 0

43 473 258 0

Di.001.99mm 172 0

.0 0

0

.ad 516.

2.00-3.34mm 0

0 0

0 0

0 0

3.35-4.74mm 0

0 43 0

0 0

0 4.76.29 mm 0

0 0

0 0

0 0

0 6.30-9.49 mm 0

0 0

0 0

0 0

1 9.50mm 0

0 0

0 0

0 0

TOTAL Sn 172 172 43 43 473 344 516 II sIZE RANGE R ;I

- Nd.

P Figure 5.5 Comparison of Live Corbicula Clam Density Estimates Among BVPS Unit 1 Cooling Tower Reservoir Sample Events, for Various Clam Shell Size Groups, 2003

  • Samples were not collected on March 14 and April 16, 2003 because of unit outage.

600 -

W 550-

a.

500 450 -

1 400-mit 350 c s 250 -

° 200 LU 150-0 5

100-z 50-0-

I I

TOTAL t mr.

6.30-9.49 m j."

SIZE

.00-1.99 mm 0.01-4.99 mm11 RANGE I

7/4

_4/16 1

till 6/9 71d 8/1 9 9116-10124 1t/tt Ol0t-0.99mm 0

0 0

0 0

0 0

0 O 1.00-1.99 mm 129 129 0

0 129 0

0 0

0 2.00-3.34 mm 516 86 0

0 0

0 0

0 0 3.35-4.74 mm 86 559 0

0 0

0 0

0 K4.75-6.29 mm 0

0 0

0 0

0 0

0 06.30-9.49 mm 0

0 0

0 0

0 0

0 0 >9.50 mm 0

0 0

0 0

0 0

0 TOTAL #Im2 731 774 0

0 129 0

0 l

0o Figure 5.6 Comparison of Live Corbicula Clam Density Estimates Among Unit 2 Cooling Tower Reservoir Sample Events, for Various Shell Size Groups, 2003.

I Figure 5.6.A UNIT I COOLING TOWER RESERVOIR OUTAGE SAMPLING, CORBICULA DENSITY FOR MARCH 14,2003 FRlOM BVPS f

Area 9.50-Egiie tyI'~tMtd A Uve or

~

.0 100.2.00 2.00.3.35 3.35-4.75 4.75-6.30 6.309.9.5

~

1.'

8 DSetloa W

.*-ped un-(mm)

(mm)

(mm)

(mm)

(mm)

(mm)

()

1 0.25 ri.

Wa 8..

Dead 20 t

S 3862 2

0.25 A +/- '3a it.-.. I ts.

Dead 7

6.

I 302.

3Ded i

I 43 Dead 56 39 IS I

24 1 Dead 11 7

4 474 t

6 0.25 DW_

iF,.;

I 0

Dead 7

6 I2 7

0.25 E-472a-4 46i*1AtM awf 9e0.25 4

2 259_a~,~:~

a0 0.25-

=."Wo van 3.1-

___rTYom~44.

91 0.25 ~.IMM ARY.'d 0

W mJ. 1.hT~~~-

i3 0.25

_'i?3~*

~

~

~

~

32-t 14 0.25

-1 Desd-I II I

I I

I.

I

=

15 0.25 gti5.4t

C'1 IBi^
e 5,-jn.~ f>

j;'_gv D-A I

An 77 17 I

1724 H

1~:;;

1 19

-11,-

j

_z.1,,"~

-l1.

-_ ~

F 16 0.25

. *,< a t;>*. -_ t t1--

l s

388

.*

Dead 1 5

3 2

216 I:

r'Ti 17 0.25 d



=

Samples Total Desd 2t1 169 101 10

.I I

I 712

. -WI I

Unit Summara Reservot I Dead I 9159479 I

IL "MI Reservot H

9159479

< 14 -

=, 12 -

rm 10 -

08 8-L.

oa 6-M 4 -

M 2-0-

i i

,7

_I mms~

TOTAL I

I A

7 4S.29 -

I24474 w afi Z4mm SIZE RANGE N. "

=X_

I i

w-I 001-0N-516 7/16 9/16 11/11 C 0.01-0.99 mm 1

0 1

0 01.00-1.99 mm 0

0 2

2 0 2.00-3.34 mm 0

0 0

1 0 3.35-4.74 mm 0

0 0

0

  • 4.75-6.29 mm 0

0 0

0 3 6.30-9.49 mm 0

1 0

0 0 >9.50mm 0

0 0

0 TOTAL I

1 3

3 Intake structure bottom samples are collected from the Ohio River at the Intake Building.

Figure 5.7 Comparison of Live Corbicula Clam Density Estimates Among Intake Structure Sample Events, for Various Clam Shell Size Groups, 2003.

80 671 75 670 70 g

50 X

669, 65 669 60

.66 m

0.

55 0

667 a~

50 45 4666 40 665

--temp -.-

elevation 30 664 3/10 4/16 5(6 6(19 7/8 8/19 9/16 10/24 11/il 2003 Monthly Sample Dates Figure 5.8 Water Temperature and River Elevation Recorded on the Ohio River at the BVPS Intake Structure, During the 2003 Monthly Sampling Dates.

______1-i 60000 50000 40000 (q

t 30000 20000 10000 0

I4 1-l

-L

Intake Structurc/Open Water Unit I Cooling Tower Reservoir I

Unit 2 Cooling Tower Reservoir l3/14 0

0 04I16 0

0 O5/n 30 10 0

06/19 0

0 0

7 7/8 52560 470 6526 08/19 50 410 410 09/16 20 110 010124 0

0 0

0 1/10 I 0

o Sample location Figure 5.9 Density of zebra mussels veligers (#/m 3) collected at the Beaver Valley Power Station Intake Structure, Unit 1 Cooling Tower Reservoir and Unit 2 Cooling Tower Reservoir.

Note: No collections were made from Unit 1 Cooling Tower Reservoir on March 14 and April 16, 2003 because of unit outage

35000 -

30000 -

25000 20000-15000-10000-5000-0 Ba Slip Splash Pool l

Emergency Outfall Facility 153/14 0

0 0

M4/16 0

0 0

0516 0

20 40 36/19 0

0 0

  • 7/8 28576 22610 23240 018/19 330 0

91

  • 9116 10 30 50 10t24 0

0 0

OHM 0

0 0

Sample location Figure 5.10 Density of zebra mussels veligers (/mm 3) collected at the Beaver Valley Power Station Barge Slip, Splash Pool, and Emergency Outfall Basin, 2003.

3 2

I 0

Intake Structure/Open Water Unit I Cooling Tower Reservoir Unit 2 Cooling Tower Reservoir B 3/14 0

0 04/16 0

2 05/6 0

0 0

06/19 0

0 0

07/8 0

0 0

0 8/19 0

0 0

3 9/16*

0 0

010/24 0

0 0

all/H 0

0 0

Figure 5.11 Density (#/m 2) of settled zebra mussels at the Beaver Valley Power Station Intake Structure, Unit 1 Cooling Tower Reservoir and Unit 2 Cooling Tower Reservoir, 2003.

Note: No collections were made from Unit 1 Cooling Tower Reservoir on March 14 and April 16, 2003 because of unit outage Note: No collections were made from Unit 2 Cooling Tower Reservoir on September 16, 2003 because of unit outage

12 1 1 10 9

8-7-

E 6-5-

4-3-

2-11 0

Barge Slip I

Splash Pool IEmergency Outfall Facility 03/14 0

~0 0

04/16 0

0 0

E5/6 0

.7;t.

0 0

06/19 I

O O

El 718 0

0 0

E 8/19 5

0 0

09116 11 0

0 310/24 1

0 0

011/11 4

0 0

Figure 5.12 Density (#Im2) of settled zebra mussels at the Beaver Valley Power Station Barge Slip, Splash Pool, and Emergency Outfall Basin, 2003.

This page Intentionally Blank

ATTACHMENTS

ATTACHMENT 1:

ENVIRONMENTAL PERMITS & CERTIFICATES Registration Number Regulator/Description Expiration BVPS EPA RCRA Identification number for regulated waste PAR000040485 activity. Also used by PA DEP to monitor regulated waste Indefinite activity.

04-02474 BVPS EPA Facility Identification Number for CERCLA/EPCRA/SARA. Used for SARA Tier II reporting Indefinite and emergency planning.

04-02475 BVPS Offsite Warehouse (22) EPA Facility Identification Number for CERCLA/EPCRA/SARA. Used for SARA Tier Indefinite II reporting and emergency planning.

PA0025615 BVPS NPDES Permit number under PA DEP and US EPA.

12/27/2006 PAG-2-004-03-025 General NPDES Permit for Temporary Office Building 12/04/2008 Construction at FE Long Term Storage Facility for SGRP.

PAG-2-004-03-027 General NPDES Permit for Security Perimeter Expansion 12/24/2008 Project 04-13281 BVPS Unit I PA DEP Facility Identification number for regulated storage tanks.

Indefinite 04-13361 BVPS Unit 2 PA DEP Facility Identification number for regulated storage tanks.

Indefinite Pending Indefinite Application for PA DEP Air operating permits currently under application for replacement of the state-only permit for emergency diesel generators and following Permits auxiliary boilers.

04-302-055,04-309-004, 04-399-006 04-399-005A OP-04-00086 200100242 US Army Permit for maintenance dredging 12131/2011 N/A PA DEP Open Burning Permit for operation of the BVPS Fire School-annual application and renewal 12131/2003 060503 4450 004L US Department of Transportation Hazardous Materials Registration renewed annually 06/30/2004 06786A Encroachment Permit Indefinite

.1 This page Intentionally Blank