RS-04-065, Request for Relief from ASME Section XI for Performance of Class 2 & 3 Raw Water Piping Repairs

From kanterella
(Redirected from ML041210175)
Jump to navigation Jump to search

Request for Relief from ASME Section XI for Performance of Class 2 & 3 Raw Water Piping Repairs
ML041210175
Person / Time
Site: Dresden, Peach Bottom, Oyster Creek, Byron, Braidwood, Limerick, Clinton, Quad Cities, LaSalle, Crane
Issue date: 04/26/2004
From: Gallagher M
AmerGen Energy Co, Exelon Generation Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
2130-04-20095, 5928-04-20122, RS-04-065
Download: ML041210175 (12)


Text

AmerGensM Exekbn.

An Exelon Company www.exeloncorp.com Nuclear AmerGen Energy Company, LLC 4300 Winfield Road Exelon Generation Warrenville, IL 60555 4300 Winfield Road Warrenville, IL 60555 10 CFR 50.55a RS-04-065 5928-04-20122 2130-04-20095 April 26, 2004 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 Braidwood Station, Units 1 and 2 Facility Operating License Nos. NPF-72 and NPF-77 NRC Docket Nos. STN 50-456 and STN 50-457 Byron Station. Units 1 and 2 Facility Operating License Nos. NPF-37 ano NPF-66 NRC Docket Nos. STN 50-454 and STN 50-455 Clinton Power Station Facility Operating License No. NPF-62 NRC Docket No. 50-461 Dresden Nuclear Power Station, Units 2 and 3 Facility Operating License Nos. DPR-1 9 and DPR-25 NRC Docket Nos. 50-237 and 50-249 LaSalle County Station, Units 1 and 2 Facility Operating License Nos. NPF-1 1 and NPF-1 8 NRC Docket Nos. 50-373 and 50-374 Oyster Creek Genetating Station Facility Operating License No. DPR-16 NRC Docket No. 50-219 Peach Bottom Atomic Power Station, Units 2 and 3 Facility Operating License Nos. DPR-44 and DPR-56 NRC Docket Nos. 50-277 and 50-278 Quad Cities Nuclear Power Station, Units 1 and 2 Facility Operating License Nos. DPR-29 and DPR-30 NRC Docket Nos. 50-254 and 50-265 Three Miie Island, Unit 1 Facility Operating License No. DPR-50 NRC Docket No. 50-289

U.S. Nuclear Regulatory Commission April 26, 2004 Page 2 Limerick Generating Station, Units 1 and 2 Facility Operating License Nos. NPF-39 and NPF-85 NRC Docket Nos. 50-352 and 50-353

Subject:

Request for Relief From ASME Section Xl for Performance of Class 2 and 3 Raw Water Piping Repairs Pursuant to 10 CFR 50.55a(a)(3)(i), Exelon Generation Company (Exelon), LLC and AmerGen Energy Company (AmerGen), LLC are requesting relief from American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code, Section Xl, "Rules for Inservice Inspection of Nuclear Power Plant Components," on the basis that the proposed alternative provides an acceptable level of quality and safety. Specifically, this proposed alternative concerns the use of Code Case N-661 for Class 2 and 3 plant raw water piping system repairs resulting from degradation mechanisms such as erosion, corrosion, cavitation, or pitting. Copies of the 10 CFR 50.55a request and Code Case N-661 are enclosed.

We request your review and approval of this fleet request by September 30, 2004 in order to support the Fall 2004 outages.

If you have any questions, please contact Tom Loomis, 610-765-5510.

Very truly yours,.

9,~2k /f~

Michael P. Gallagher Director, Licensing and Regulatory Affairs Exelon Generation Company, LLC AmerGen Energy Company, LLC Enclosures cc:

Regional Administrator - NRC Region I Regional Administrator - NRC Region IlIl NRC Project Manager - Braidwood Station NRC Project Manager-Byron Station NRC Project Manager-Dresden Nuclear Power Station NRC Project Manager - LaSalle County Station NRC Project Manager - Peach Bottom Atomic Power Station NRC Project Manager - Quad Cities Nuclear Power Station NRC Project Manager - Clinton Power Station NRC Project Manager - Oyster Creek Generating Station NRC Project Manager-Three Mile Island, Unit 1 NRC Project Manager - Limerick Generating Station

ATTACHMENT 1 Request for Relief From ASME Section Xl, IWA-4120(a) of 1989 Edition (or IWA-4410(a) and (b) of 1995 Edition through 1996 Addenda) and IWA-4310 of 1989 Edition (or IWA-4611.1 of 1995 Edition through 1996 Addenda) for Performance of Class 2 and 3 Raw Water Piping Repairs 10 CFR 50.55a Request Proposed Alternative In Accordance with 10 CFR 50.55a(a)(3)(i)

Page 1 of 3 ASME Code Components Affected All ASME Class 2 and 3 carbon steel plant raw water piping systems.

Applicable Code Edition and Addenda

PLANT INTERVAL EDITION START PROJECTED END Byron Station, Unit 1 Second 1989 Edition, no addenda June 30,1996 June 30, 2005 Byron Station, Unit 2 Second 1989 Edition, no addenda August 16,1998 August 16, 2007 Braidwood Station, Second 1989 Edition, no addenda.

July 29,1998 July 28, 2008 Unit 1 Unit 2 Second 1989 Edition, no addenda.

October 17, 1998 October 16, 2008 Quad Cities Nuclear 1995 Edition through 1996 Mrh1,20 ac

,21 Power Station, Units 1 Fourth Addenda March 10, 2003 March 9, 2013 and 2 LaSalle County Second 1989 Edition, no addenda November 23,1994 October 11, 2006 Station, Unit 1 LaSalle County Second 1989 Edition, no addenda October 17, 1994 July 4, 2007 Station, Unit 2 Clinton Power Station Second 1989 Edition, no addenda January 1, 2000 December 31, 2009 Dresden Nuclear 1995 Edition with 1996 Jaur2,03 Jnay1903 Power Station, Units 2 Fourth Addenda January 20, 2003 January 19, 2013 and 3 Three Mile Island, Third 1995 Edition, 1996 April 20, 2001 April 19,2011 Unitt Addenda Apr 2,1200 Apr 1, 2011 Peach Bottom Atomic Third 1989 Edition, no Addenda November 5,1998 November 4, 2008 Power Station, Unit 2 Peach Bottom Atomic Third 1989 Edition, no Addenda August 15, 1998 August 14, 2008 Power Station, Unit 3 Oyster Creek Fourth 1995 Edition, through 1996 October 15, 2002 October 14, 2012 Generating Station Addenda Limerick Generating Second 1989 Edition, no Addenda January 8, 2000 January 7, 201 0 Station, Units 1 and 2 10 CFR 50.55a Request Proposed Alternative In Accordance with 10 CFR 50.55a(a)(3)(i)

Page 2 of 3

Applicable Code Requirement

ASME Code, Section Xi, IWA-4120(a) of 1989 Edition (or IWA-4410(a) and (b) of 1995 Edition through 1996 Addenda) requires that repairs be performed in accordance with the Owner's Design Specification/Owner's Requirements and the original or later Construction Code of the component or system.

ASME Code, Section Xl, IWA-431 0 of 1989 Edition (or IWA-461 1.1 of 1995 Edition through 1996 Addenda) requires that the defect be removed or reduced in size in accordance with Article IWA-4000.

Reason for Request

Relief is requested from replacement or internal weld repair of wall thinning conditions resulting from various wall thinning degradation mechanisms such as erosion, corrosion, cavitation, and pitting in Class 2 and 3 carbon steel raw water piping systems in accordance with the design specification/owner's requirements and the original construction code. The primary reason for this request is to provide adequate time for additional examination of adjacent piping so that pipe replacement can be planned to reduce impact on system availability including Maintenance Rule applicability and availability of replacement materials.

Proposed Alternative and Basis for Use Exelon Generation Company (Exelon), LLC and AmerGen Energy Company (AmerGen), LLC will implement the requirements of ASME Code Case N-661 for Class 2 and 3 plant raw water piping system repairs resulting from degradation mechanisms such as erosion, corrosion, cavitation, or pitting as an alternative to the requirements of IWA-4000. These type defects are typically identified by small leaks in the piping system or by pre-emptive non-code required examinations perfomied by the Licensee to monitor the degradation mechanisms. The alternative repair technique described in Code Case N-661 involves the application of additional weld metal on the exterior of the piping system, which restores the wall thickness requirement. This repair technique will be utilized whenever engineering evaluation determines that such a repair is suitable for the particular defect or degradation being resolved.

Provisions for use of this Code Case will be addressed in the Repair and Replacement Program.

Those provisions will require that adjacent areas be examined to verify that the entire flawed area will be encompassed by the repair and that there are no other unacceptable degraded locations within a representative area dependent on the degradation mechanism present. An evaluation of the degradation mechanism will be performed to determine the re-examination schedule to be performed over the life of the repair. The repair will be considered to have a maximum service life of two fuel cycles unless examinations during each of the two fuel cycles are performed to establish the expected life of the repair.

Additionally, the following restrictions will be placed on the use of Code Case N-661, to assure that the use of the Code Case will provide an acceptable alternative pursuant to 10 CFR 50.55a(a)(3)(i):

(a)

If the cause of the degradation has not been determined, the repair is only acceptable for one cycle.

(b)

Weld overlay repair of an area can only be performed once in the same location.

(c)

When through-wall repairs are made by welding on surfaces that are wet or exposed to water, the weld overlay repair is only acceptable until the next refueling outage.

10 CFR 50.55a Request Proposed Alternative In Accordance with 10 CFR 50.55a(a)(3)(i)

Page 3 of 3 The basis for use of the repair technique described in Code Case N-661 is Section Xi of the ASME Code determined this repair technique provides an acceptable alternative to the requirements of IWA-4000 and provides an acceptable level of quality and safety. Therefore, the proposed alternative is justified per 10 CFR 50.55a(a)(3)(i).

Code Case N-661 was approved by the ASME Section Xl Code on July 23, 2002; however, it has not been incorporated into NRC Regulatory Guide 1.147 and thus is not available for application at nuclear power plants without specific NRC approval. Therefore, Exelon Generation Company (Exelon), LLC and AmerGen Energy Company (AmerGen), LLC is documenting the request to apply the alternative repair technique described in the Code Case via this relief request. A copy of ASME Section XI Code Case N-661 is attached for reference.

Duration of Proposed Alternative The proposed alternative is for the use of the remainder of each plant's ten (10) year interval or until the NRC publishes Code Case N-661 in a future revision of the applicable Regulatory Guide.

Precedents Edwin I. Hatch Nuclear Plant, Units 1 and 2, Joseph M. Farley Nuclear Power Plant, Units 1 and 2, and Vogtle Electric Generating Plant, Units 1 and 2 (TAC Nos. MB8959, MB8960, MB8961, MB8962, MB8963, and MB8964), dated November 21, 2003.

ATTACHMENT 2 Request for Relief From ASME Section Xi for Performance of Class 2 and 3 Raw Water Piping Repairs Code Case N-661

CASE N-661 CASES OF ASME BOILER AND PRESSURE VESSEL CODE Approval Date: July 23, 2002 See Numeric Index for expiration and any reaffirmation dates.

Case N-661 Alternative Requirements for WVall Thickness Restoration of Classes 2 and 3 Carbon Steel Piping for Raw Water Service Section XI, Division I Inquiry: As an alternative to replacement or internal weld repair, what requirements may be applied for wall thickness restoration of Classes 2 and 3 carbon steel raw water? piping systems that have experienced internal wall thinning from localized errosion, corrosion, cavita-tion, or pitting?

Reply: It is the opinion of the Committee that areas of Classes 2 and 3 carbon steel raw water piping

experiencing internal wall thinning from localized ero-sion, corrosion, cavitation, or pitting may have the wall thickness restored externally by means of a weld-deposited carbon or low-alloy steel reinforcement on the outside surface of the piping in accordance with the following requirements. Excluded from these provi-sions are conditions involving corrosion-assisted crack-ing or any other form of cracking.

1.0 GENERAL REQUIREMENTS (a) The wall thickness restoration shall be performed in accordance with a Repair/Replacement Plan satisfying the requirements of IWA-4150.2 (b) The wall thickness restoration shall meet the re-quirements of IWA-4000,3 except as stated in this Case.

(c) If the minimum required thickness of deposited weld metal necessary to satisfy the requirements of 3.0 is greater than the nominal thickness for the size and schedule of the piping, the provisions of this Case shall not apply. In addition, the total thickness of filler metal applied over multiple repairs shall not exceed the original nominal thickness of the piping.

or brackish/salt water used in plant equipment, area coolers, and heat exchangers. In many plants it is referred to as "Service Water."

21WA4140 in the 1989 Edition with the 1991 Addenda through 1995 Edition. IWA4130 (Repair Program) in the 1989 Edition with the 1990 Addenda and earlier Editions and Addenda.

3IWA4000nOOO and IWC/IWD14000n000, as applicable, in the 1989 Edition with the 1990 Addenda and earlier Editions and Addenda.

41WA4150 in the 1989 Edition with the 1991 Addenda through 2.0 INITIAL EVALUATION The material beneath the surface to which the weld overlay is to be applied shall be evaluated to establish the existing average wall thickness and the extent and configuration of degradation to be reinforced by the weld overlay. The adjacent area shall be examined to verify that the repair will encompass the entire defective area. Consideration shall be given to the cause of degradation. The extent of degradation in the piping, shall be evaluated to ensure that there are no other unacceptable locations within the surrounding area that could affect the integrity of the repaired piping. The dimensions of the surrounding area to be evaluated shall be determined by the Owner, considering the type of degradation present. The effect of the repair on the piping, and any remaining degradation shall be evaluated in accordance with IWA-4160.4 3.0 DESIGN 3.1 General Design Requirements (a) Unless otherwise established by theoretical or experimental analysis, or by proof testing as provided for in 3.3 or 3.4, the full thickness of the weld overlay shall extend a distance of at least s in each direction beyond the area predicted, over the design life of the restoration to infringe upon the required thickness. 5 where

$= 23/4,FRii.;

R = outer radius of the component tnom nominal wall thickness of the component Edges of the weld overlay shall be tapered to the existing piping surface at a maximum angle ("a" in 1995 Edition. IWA4130 (Repair Program) in the 1989 Edition with the 1990 Addenda and earlier Editions and Addenda.

5Design thickness as prescribed by the Construction Code.

61WVA4540 in the 1989 Edition with the 1991 Addenda through SUPP. 5 - NC

CASE (continued)

N-661 CASES OF ASME BOILER AND PRESSURE VESSEL CODE t

branch reinforcement Xa2'22,/Rtnom FIG. 1 BRANCH REINFORCEMENT Fig. I) of 45 deg. Final configuration of the reinforce-ment shall permit the examinations and evaluations required herein, including any required preservice or inservice examinations of encompassed or adjacent welds.

(b) The thickness shall be sufficient to maintain required thickness for the predicted life of the repair, and, except for the tapered edges, the overlay shall have a uniform thickness.

(c) The tensile strength of the weld filler metal for the reinforcement shall be at least that specified for the base metal to which it is applied.

(d) The predicted maximum degradation of the over-laid piping and the overlay over the design life of the restoration shall be considered in the design. The predicted degradation of the piping shall be based on in situ inspection and established data for similar base metals. If the weld overlay is predicted to become exposed to the corroding medium, the predicted degrada-tion of the overlay shall be based upon established data for base metals or weld metals with similar chemical composition to that of the filler metal used for the weld overlay.

(e) The effect of weld overlay application on interior coatings shall be addressed in the Repair/Replacement Plan (previously Repair Program).

3.2 Design The design of weld overlays not prequalified by 3.3, 3.4, or 3.5 shall be in accordance with the applicable requirements of the Construction Code or NC/ND-3100 and NC/ND-3600 (including Appendix II), and shall consider the weld overlay as an integral portion of the piping or component upon which it is applied (not as a weld). The allowable stress values of the base metal shall apply to the design of the deposited weld metal.

The following factors shall be considered, as applicable, in the design and application of the reinforcement:

(a) The shrinkage effects, if any, on the piping; (b) Stress concentrations caused by application of the overlay or resulting from existing and predicted piping internal surface configuration; (c) If flexibility analysis was required by the original Construction Code, the effect of the weld overlay shall be reconciled with the original analysis. For rectangular-shaped overlays on piping designed to NC/ND-3650 and aligned parallel or perpendicular to the axis of the piping, unless a lower stress intensification factor (SIF or i) is established, an SIF (i) of 2.1 shall be applied for overlays on straight pipe and adjacent welds. Also, a stress multiplier of 1.7 shall be applied to the SIF (i) for standard elbows; and an SIF (i) of 2.1 shall be 1174 SUPP. 5-NC

CASE (continued)

N-661 CASES OF ASNIE BOILER AND PRESSURE VESSEL CODE applied for tees and branch connections when the toe of the overlay is not less than 2'/1,RjW from any branch reinforcement in Fig. 1.

3.3 Proof Test Qualification as a Piping Product As an alternative to design, the configuration of weld overlays may be qualified by performance of proof testing of a mockup in accordance with the following requirements:

(a) A satisfactory mockup burst test shall qualify the design or configuration for application in the same orientation on the same type of item, and the same location on fittings, when the following conditions are satisfied (see Fig: 1).

(1) The base metal is of the same P-No. and Group Number when impact properties are applicable, as the base metal tested.

(2) The specified minimum tensile strength of the item does not exceed that specified for the base metal tested.

(3) The average thickness of the overlay areas is at least the thickness of the mockup plug, u.

(4) The overlap on the full thickness of base metal, s, is at least that of the mockup.

(5) The transition angle at the outer edges of the overlay, a, is not greater than that of the mockup.

(6) The overlay surface finish is similar to or smoother than that tested.

(7) The maximum proportionate axial dimension, LID, is not more than that tested.

(8) The maximum proportionate circumferential dimension, CID, is not more than that tested.

(9) The nominal diameter is not less than one-half nor more than two times the diameter tested.

(10) The nominal thickness/diameter ratio, tMD, is not less than one-half nor more than three times the MID, ratio tested.

(b) The mockup base shall consist of new base material of similar configuration, or type of item, as the item to be overlaid. A rounded-corner segment of the base material shall be removed to represent the maximum proportionate size (axial dimension of L and circumferential dimension of C) and location of thinning or pitting to be compensated for by the weld overlay.

A plug of the same base metal and of uniform thickness, it, which shall not exceed the smallest average thickness on which the overlays will be permanently applied, shall be full-penetration welded around the opening and flush with the outside surface of the piping. Alterna-tively, an equivalent volume of base metal may be removed from the inside surface of the mockup by machining or grinding, without need for welding in a closure plug.

(c) The mockup weld overlay shall be applied in accordance with the design or specified configuration using the specified weld filler metal. Maximum section thickness at the overlaid opening (weld metal plus base metal plug, or i + wv) shall not exceed 871/2% of the nominal thickness of the piping.

(d) Straight pipe equivalent to a minimum of one pipe diameter, or one-half diameter for piping over NPS 14, shall be provided (butt-welded to the mockup, if necessary) beyond both ends of the overlay. The piping shall be capped, and the completed mockup assembly shall be thoroughly vented and hydrostatically pressure tested to bursting. To qualify the design for general application within the limits of 3.3(a), burst pressure shall not be less than; p

2 tSa,,

Do, where P= minimum acceptable burst pressure, psi t= minimum specified thickness (excluding manu-facturing tolerances) of the base metal being tested, in.

Sac, = reported actual tensile strength of the base metal being tested, psi Do= outside diameter of the pipe, in.

(e) If flexibility analysis was required by the original Construction Code, the effect of the weld overlay shall be reconciled in accordance with 3.2(c).

3.4 Proof Test Qualification for Specific Applications As an alternative to design by analysis or proof test qualification as a piping product, the design or configuration of weld overlays may be qualified for limited service conditions using the provisions of NCI ND-6900, "Proof Tests to Establish Design Pressure,"

except that component hydrostatic testing is not required (other than as required by IWA-40003). The mockups shall be fabricated and tested in accordance with the provisions of 3.3(b), (c), and (d), and shall be applied in accordance with the provisions and conditions of 3.3(a). The provisions of 3.3(e) shall be met.

175 SUPP. 5 - NC

CASE (continued)

N-661 CASES OF ASME BOILER AND PRESSURE VFSSEL CODE 3.5 Prequalified Design Application of weld overlays n straight pipe, portions of tees not less than 21/2 rRt.,om from any branch rein-forcement in Fig. 1, standard elbows, and associated welds to correct limited degradation shall be exempt from the requirements of 3.2 through 3.4 provided all of the following conditions are satisfied.

(a) All the requirements of 3.1 apply.

(b) The provisions of 3.3(e) shall be met.

(c) The full thickness of weld overlay shall not exceed a maximum axial length of the greater of 6 in. or the outside diameter of the piping.

(d) The finished overlay shall be circular, oval, full-circumferential or rectangular in shape.

(1) For each repair, the maximum dimension com-pensated by a circular overlay shall not exceed 2/3 the nominal outside diameter of the piping.

(2) Rectangular overlays shall be aligned parallel with or perpendicular to the axis of the piping, and corners shall be rounded with radii not less than the ovelay thickness.

(3) For oval overlays, the end radii shall not be less than 3/4Tt ;;, and the axis of the overlay shall be aligned parallel with or perpendicular to the axis of the piping.

(e) The distance between toes of adjacent overlays shall not be less than tnom.

5.0 INSTALLATION (a) The entire surface area to which the weld overlay is to be applied shall be examined using the liquid penetrant or magnetic particle method, with acceptance criteria in accordance with NCIND-2500, NC/ND-5300 for the product form (base metal or weld) involved.

(b) If through-wall repairs are required to satisfy the acceptance criteria, or result from application of the weld overlay, they shall be accomplished by sealing with weld metal using a qualified weld procedure suitable for open-root welding. This weld shall be examined in accordance with 5.0(a). In addition, the first layer of overlay over the repaired area shall be examined in accordance with 5.0(a).

(c) Overlay weld metal shall be deposited using a grove-welding procedure qualified in accordance with Section IX and the Construction Code, or Section IX and Section XI, IWA-4610 and either IWA-4620 or IWA-4650. 7 The qualified minimum thickness specified in the weld procedure does not apply to the weld overlay or associated base metal repairs. 8 (d) The surface of the weld overlay shall be prepared by machining or grinding, as necessary, to permit performance of surface and volumetric examinations required by 6.0. For ultrasonic examination, a surface finish of 250 RMS or better is required.

6.0 EXAMINATION 4.0 WATER-BACKED APPLICATIONS (a) Manual application of overlays on water-backed piping shall be restricted to P-No. I base materials.

Welding of such overlays shall use the SMAW process and low-hydrogen electrodes. In addition, the surface examination required in 6.0 shall be performed no sooner than 48 hr after completion of welding. For such overlays consideration should be given to using a temper bead technique similar to that described in IWA-4650.6 (b) Piping with wall thickness less than the diameter of the electrode shall be depressurized before welding.

the 1995 Edition. IWE.4200 in the 1986 Edition with the 1988 Addenda through the 1989 Edition with the 1990 Addenda. IWE-4320 in the 1986 Edition with the 1987 Addenda and earlier Editions and Addenda.

7IWA-4500 and either IWA4510 or IWA-4540 in the 1989 Edition (a) The completed weld overlay shall be examined using the liquid penetrant or magnetic particle method and shall satisfy the surface examination acceptance criteria for welds of the Construction Code or NC/

ND-5300.

(b) The weld overlay, including the existing piping upon which it is applied, shall be examined to verify acceptable wall thickness.

(c) Weld overlays shall be volumetrically examined as base metal repairs when required by the Construction Code, except as follows:

(1) Weld overlays not exceeding 10 in.2 surface area are exempt from volumetric examination.

with the 1991 Addenda through 1995 Edition. IWA.45 10 or IWE-4200 in the 1986 Edition with the 1988 Addenda through 1989 Edition with the 1990 Addenda. IWB.4320 or IWE-4320 in the 1986 Edition with the 1987 Addenda or earlier Editions and Addenda.

sExceplion to IWA-4000.

91WA-3000 and IWB-3514 in the 1989 Edition with the 1990 1176 SUPP. 5-NC

CASE (continued)

N-661 CASES OF ASME BOILER AND PRESSURE VESSEL CODE (2) Other weld overlays shall be exempt from volumetric examination when the finished applied thick-ness (wv in Fig. I) does not exceed:

(a) 1/3t fo r t 3/4 in.

(b) I/4 in. for 3/4 in. < t

  • 2'/2 in.

(c) The lesser of 3/8 in. or 10% of t for t >

2'/2 in.

where t= finished full-section thickness of compensated area (e.g., iv + u in Fig. I)

When volumetric examination is required, the full volume of the finished overlay, excluding the tapered edges, but including the volume of base metal required for the design life of the overlay, shall be examined using either the ultrasonic or radiographic method, and shall, to the depth at the surface of the existing piping, satisfy the acceptance criteria for weldments of the Construction Code or NC/ND-5300. The volume of the existing piping, beneath the weld overlay, taken credit for in the design, shall satisfy the volumetric acceptance

'Raw water is defined as water such as from a river, lake, or well criteria of NC/ND-2500, NC/ND-5300 for the product form, or IWA-3000.9 7.0 INSERVICE EXAMINATION (a) The Owner shall prepare a plan for additional examination to verify that minimum wall thickness is not violated over the life of the repair. The frequency and method of examination shall be determined based on an evaluation of the degradation mechanism.

(b) The maximum expected life of the repair shall be two fuel cycles unless examinations during each of the two fuel cycles are performed to establish the expected life of the repair.

8.0 DOCUMENTATION Use of this Case shall be documented on an NIS-2 Form.

Addenda and earlier Editions and Addenda.

1177 SUPP. 5 - NC