ML041030303

From kanterella
Jump to navigation Jump to search
2004 Initial Exam, W/T JPMs-APPDX E
ML041030303
Person / Time
Site: Grand Gulf 
Issue date: 09/16/2003
From:
NRC Region 4
To:
References
50-416/04-301
Download: ML041030303 (1)


Text

S:\\DRS\\OB\\EXAMS\\GG\\February 2004 Exam\\GG2004 JPM-B-QualityRvw-MSH.wpd

- Page 1 -

APPENDIX E - REGION IV OPERATING TEST JOB PERFORMANCE MEASURE QUALITY REVIEW MATRIX JPM#

1.

Dyn (D/S) 2.

LOD (1-5)

3. Attributes
4. Job Content Errors 5.

U/E/S 6.

Explanation (See below for instructions)

IC Focus Cues Critical Steps Scope (N/B)

Over-lap Job-Link Minutia B.1.1 D

3 S

B.1.2 D

3 S

B.1.3 S

3 S

B.1.4 D

1 X

U Too simple and short to be of discriminatory value on the exam; applicant is allowed to skip steps 2 and 3, so there really only 1 step with action required of the applicant. OK-- Low Freq-High Importance B.1.5 D

3 S

B.1.6 D

3 S

B.1.7 D

3 S

B.2.8 S

3 S

B.2.9 S

3 S

B.2.10 S

3 S

Instructions for Completing Matrix This form is not contained in or required by NUREG-1021. Utilities are not required or encouraged to use it. The purpose of this form is to enhance regional consistency in reviewing operating tests. Additional information on these areas may be found in Examination Good Practices Appendix D. Check or mark any item(s) requiring comment and explain the issue in the space provided.

1.

Determine whether the task is dynamic (D) or static (S). A dynamic task is one that involves continuous monitoring and response to varying parameters. A static task is basically an system reconfiguration or realignment.

2.

Determine level of difficulty (LOD) using established 1-5 rating scale. Levels 1 and 5 represent inappropriate (low or high) discriminatory level for the license being tested.

3.

Check the appropriate box when an attribute weakness is identified:

The initiating cue is not sufficiently clear to ensure the operator understands the task and how to begin.

The JPM does not contain sufficient cues that are objective (not leading).

All critical steps (elements) have not been properly identified.

Scope of the task is either too narrow (N) or too broad (B).

Excessive overlap with other part of operating test or written examination.

4.

Check the appropriate box when a job content error is identified:

Topics not linked to job content (e.g., disguised task, not required in real job).

Task is trivial and without safety significance.

5.

Based on the reviewers judgment, is the JPM as written (U)nacceptable (requiring repair or replacement), in need of (E)ditorial enhancement, or (S)atisfactory?

6.

Provide a brief description of problem in the explanation column. Provide conclusion on whether JPM SET criteria satisfied (i.e., number/distribution of safety functions, A.3 and A.4 integrated with parts B/C, Admin topics per section meet ES).