1 Management of Materials Issues RIC 2004 Emergent Technical Issues, Session T-11 Alex Marion Senior Director, Engineering March 11, 2004

2 Background

 Indian Point 2 - February 2000

 Alloy 600 base metal - steam generator tube rupture

 VC Summer - October 2000

 Alloy 82/182 weld - reactor vessel nozzle to hot leg coolant pipe

 Quad Cities 1 - January 2002

 Jet pump holdown beam failure

3 Background

 Oconee 1, 2 & 3; ANO 1 November 2000 -

March 2001

 A600 base metal and A82/182 welds -

through wall leaks in CRDM nozzles

 Davis-Besse - March 2002

 A600 base metal and A82/182 welds -

through wall leaks and boric acid corrosion

 South Texas Project - April 2003

 Bottom mounted instrument nozzle leaks

4 Background

 Task Force on Materials & Materials Assessment Working Group 8/02

 Self-Assessment

 NEI Executive Committee Resolution 11/02

 NSIAC

 NSIAC SG

5 Scope

 PWR Primary System

 BWR Drywell

 Secondary Side Steam Generators

 Materials Issues Related to Nuclear Fuel

 EPRI Programs and NSSS Owners Groups

6 Self-Assessment

 EPRI Issue Programs

 BWRVIP

 MRP (responses from each ITG - 4)

 RFP

 SGMP

 Owners Group Programs

 BWROG

 B&WOG (OTSG, Chemistry, NDE and Materials)

 CEOG (Chemistry, SG and Section XI)

 WOG/CEOG Materials

 Other EPRI Programs

 NDE Center

 Water Chemistry Control

 Corrosion Control

 Other

 PDI

7 Self-Assessment

 Oversight & Coordination

 Culture Issues

 Commitment, Resolution and Implementation

 Personnel

 Communication

 Regulatory Interface

8 Self-Assessment

 Recommendations

 Create executive-level and technical oversight groups

 Establish policy on the management of materials issues

 Use the NEI Initiative Process

 Expand INPOs role

 Enhance communications

 Define regulatory interface

9 NEI 03-08 Guideline

 Establishes two standing committees

 Executive Oversight

 Technical Advisory

 Establishes policy

 Defines roles, responsibilities, and expectations

 Provides for an integrated approach

10 Industry Initiative

 The objective of this Initiative is to assure safe, reliable and efficient operation of U.S nuclear power plants in the management of materials issues.

 Each licensee will endorse, support and meet the intent of NEI 03-08, Guideline for the Management of Materials Issues.

This initiative is effective January 2, 2004.

11 Industry Initiative

 The purpose of this Initiative is to:

 Provide a consistent management process

 Provide for prioritization of materials issues

 Provide for proactive approaches

 Provide for integrated and coordinated approaches to materials issues

 Provide for oversight of implementation

12 Industry Initiative

 Actions required by this Initiative include:

 Commitment of executive leadership and technical personnel

 Commitment of funds for materials issues within the scope of this Initiative

 Commitment to implement applicable guidance documents

13 Actions

 Unanimous approval by Chief Nuclear Officers - May 2003

 Develop and implement transition plan

 Strategic Focus/Plan

 Project Control

 Budget

 Implementation/Assessment

 Regulatory Interface

 Communication

 Implementation January 2004