TEXAS ENGINEERING EXPERIMENT STATION TEXAS A&M UNIVERSITY 3575 TAMU COLLEGE STATION, TEXAS 77843-3575 NUCLEAR SCIENCE CENTER 979/845-7551 FAX 979/862-2667 March 26, 2004 2004-0028 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C 20555

Subject:

2003 Annual Report (NRC Facility License R-83)

To Whom It may Concern:

Enclosed please find the 2003 Annual Report for the Texas A&M University Nuclear Science Center. If you have any questions regarding this, pleas feel free to call me at (979) 845-7551.

Sincerely, Dr. W. D. Reece, Director Enclosure LV/jlg Xc:

2.11/Central File Annual Report 09-0 RESEARCH AND DEVELOPMENT FOR MANKIND http.//nsc.tamu.edu

Texas A&M University Nuclear Science Center 2003 Annual Report Nuclear Science Center Texas Engineering Experiment Station Texas A&M University System College Station, Texas.

Texas A&M University System Texas Engineering Experiment Station Nuclear Science Center 2003 Annual Report Facility Operating License R-83 1095 Nuclear Science Road College Station, Texas 77843-3575 March 2003

Texas A&M University System Nuclear Science Center Annual Report 2003 CONTENTS

1.

Introduction......................................

4 1.1 Nuclear Science Center Staff......................................

4

2.

Reactor Utilization for 2003......................................

6 2.1 Research Enhancement Program (REP)......................................

7 2.2 TAMU Academic Support Program......................................

7 2.3 DOE University Reactor Sharing Program......................................

7 2.4 Commercial Activity and External Research......................................

7

3.

Facility and Procedure Changes......................................

8 3.1 Facility Modifications.....................................

8 3.2 Experiment Authorizations and Modifications......................................

8

4.

Reactor Maintenance and Surveillance....................................

8 4.1 Scheduled Maintenance......................................

8 4.2 Unscheduled Maintenance......................................

8 4.3 Emergency Planning and Review......................................

9 4.4 Unscheduled Shutdowns......................................

9

5.

Health Physics Surveillance.....................................

1 5.1 Radioactive Shipments.............................

1 1 5.2 Personnel Monitoring.............................

11 5.3 Facility Monitoring.............................

1 5.4 Particulate Effluent Monitoring.............................

12 5.5 Gaseous Effluent Monitoring.............................

13 5.6 Liquid Effluent Monitoring.............................

14

6.

Environmental Monitoring.......................

15 6.1 Environmental Samples......................

16 6.2 Site Boundary Dose Rate......................

16

7.

Radioactive Waste Shipments......................

18

8.

Reactor Safety Board.......................

18 8.1 Reactor Safety Board Membership (2003).............................

18 2

Texas A&M University System Nuclear Science Center Annual Report 2003 List of Tables Table 2-1:

Table 4-1:

Table 4-2:

Table 5-1:

Table 5-2:

Table 5-3:

Table 5-4:

Table 6-1:

Table 6-2:

Reactor Utilization Summary in 2003.........................................

6 Unscheduled Maintenance..........................................

8 Unscheduled Shutdowns.........................................

10 Total Dose Equivalent (mrem) recorded on Area Monitors.................................. 12 Monthly Particulate Effluent Releases.........................................

12 Monthly Gaseous Effluent Releases.........................................

13 Monthly Liquid Effluent Releases.........................................

15 Environmental Sample Analysis........................................

16 Site Boundary Dose Rates........................................

17 List of Figures Figure 1-1:

Figure 2-1:

Nuclear Science Center Organization Chart..............................

5 Annual Reactor Utilization..............................

6 3

Texas A&M University System Nuclear Science Center Annual Report 2003

1.

Introduction The Texas A&M University Nuclear Science Center (NSC) is a multi-disciplinary research and education center supporting basic and applied research in nuclear related fields of science and technology as well as providing educational opportunities for students in these fields as a service to the Texas A&M University System and the state of Texas. The NSC also provides services to commercial ventures requiring radiation or isotope production services.

The NSC reactor, a I-MW, pool-type TRIGA reactor, is at the heart of the NSC facilities which includes: a 2-MW micro-beam accelerator, a 6WCo gamma calibration range, a real-time neutron radiography facility, a large-object irradiation cell, hot cells and manipulators, radiation measurement laboratories, radiochemical laboratories, five HPGe gamma spectroscopy systems, and a variety of instruments for radiation detection and measurement.

The NSC reactor design allows for easy load/unload of various types of samples. The NSC actively produces various kinds of radioisotopes for industry, hospitals, and academic users. The NSC provides nationally recognized neutron activation analysis (NAA) services to many research and academic institutions in the United States. The NSC reactor also actively supports the Nuclear Engineering Department on campus, one of the largest nuclear engineering programs in the United States. The NSC is one of the major attractions on campus. Last year alone, the NSC hosted 1164 visitors including: elementary, middle, high school, and college students, faculty members, clients, and national laboratory and industrial scientists and engineers. Through these tours, the NSC teaches people with widely varying backgrounds what nuclear power is, and what radiation is and a little about nuclear science.

With the strong support from the University, the NSC is continuously increasing the diversity of its facilities and services. The NSC is continuing to develop the third generation 124Xe irradiation system for 1251. NSC and the Nuclear Engineering Department are maintaining the Innovations in Nuclear Infrastructure for Education Grant. As part of this, the NSC is building a robust neutron detection system and is producing the prototype for distance learning modules. NSC refurbished the delayed neutron counting system and the neutron radiography system.

This annual report has been prepared to satisfy the reporting requirements of Technical Specification 6.6.1 of the facility operating license R-83 and of the Department of Energy University Reactor Fuel Assistance Program subcontract No C87-101594 (DE-AC07-76ER02426). The facility license renewal application was filed with NRC on February 2003. The facility is currently operating under timely renewal.

1.1 Nuclear Science Center Staff The staff at the Nuclear Science Center consists of into four major groups including: Reactor Operations, Reactor Maintenance, Health Physics/Technical Coordination, and Administrative Services (Figure 1-1). Personnel directly involved with the operation and maintenance of the 4

Texas A&M University System Nuclear Science Center Annual Report 2003 reactor are NRC-licensed operators. The NSC is committed to its educational responsibilities and many members of the staff are part or full-time students at Texas A&M University.

Nuclear Science Center December 2003 Figure 1-1. NSC Organization Chart The Texas Engineering Experiment Station (TEES) of the Texas A&M University System operates the Nuclear Science Center (NSC). The Director of the Nuclear Science Center (NSC) is responsible to the Deputy Director of the TEES for the administration and the proper and safe operation of the facility. In addition to the internal structure, the Reactor Safety Board (RSB) advises the Deputy Director of the TEES and the Director of the NSC on issues or policy pertaining to reactor safety. The Texas A&M University Environmental Health and Safety 5

Texas A&M University System Nuclear Science Center Annual Report 2003 Department (EHSD) provide assistance when it is required for emergencies and for special operations as agreed.

2.

Reactor Utilization for 2003 The Nuclear Science Center (NSC) reactor has been in operation since 1962. The reactor is a 1-MW, MTR-converted TRIGA reactor. The reactor uses highly enriched uranium fuel (70%), but will use a 20% enriched fuel core when DOE funds become available. Core VIII-A is the current core configuration and has been in use since March 1986. The NSC reactor is pulse operational and is pulsed up to powers of approximately 1,100 MW for nuclear engineering laboratories, staff training, and public tours.

The NSC reactor operated for 1947.2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> in 2003 with a total integrated power of 79.8MW-days. There were 526 irradiations and services performed at the NSC during the reporting period. The NSC provided services to TAMU departments, other universities, research centers and secondary schools in and outside the state of Texas. Many departments at TAMU and other universities used the reactor regularly in the past year.

The NSC reactor had about 97%

availability in 2003.

Table 2-1. Reactor Utilization Summary in 2003 Days of Reactor Operation 241 Integrated Power (MW-days) 79.8 Number of Hours at Steady-State 1947.2 Number of Pulses 55 Number of Reactor Irradiations (RFS) 526 Beam Port/Thermal Column Experiment Hours 535.1 Hours Irradiation Cell Use 2.8 Number of Visitors 1164 Unscheduled Shutdowns 6

.g 2,300 2,209 c

2,200 2,120 2.155 2,143 2,100 2,8 2,000 1.944 1.924 1,963 1,945 1,965 1,947 O1,900 5-1,800 o1,700

~.1,600 1,500 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 Year Figure 2-1. Annual Reactor Utilization 6

Texas A&M University System Nuclear Science Center Annual Report 2003 2.1 Rcsearch Enhancement Program (REP)

The 7 0th Texas Legislature established the Research Enhancement Program (REP) in 1987 to

'"encourage and provide for research conducted by faculty members." The REP replaced the former "Organized Research" program. The TAMU Office of the Vice President for Research administers the REP funds and generally allocates these funds to the NSC early in the fiscal year.

TAMUS faculty members who desire to use the irradiation services at the NSC reactor must apply at the NSC to receive local funding for each individual project. This proposal method is flexible and does not hinder a project's start-up time.

2.2 TAMIU Academic Support Program Texas A&M University (TAMU) provides funding for the reactor for such academic activities as nuclear engineering laboratories, neutron activation analysis demonstrations and laboratories, graduate student thesis and dissertation research, and undergraduate research projects.

The program has been very successful and is crucial for many graduate students who use the NSC reactor for research and have not received research grants. The wide range of academic users from the university reflects in the NSC's reputation as a multi-disciplinary institution.

2.3 DOE University Reactor Sharing Program The DOE University Reactor Sharing Program provides funds for reactor experimentation to those institutions that do not normally have access to a research reactor. The Nuclear Science Center (NSC) has participated in the program since 1980. During the 2002-2003-contract year, nine research institutions utilized the NSC with the support of the Reactor Sharing Program.

Additionally, the funding provided reactor tours and "hands-on" projects to many secondary schools. The research projects supported by the program include items such as dating geological material and producing high current super conducting magnets. The funding gave several small colleges and universities the opportunity to use the NSC facilities for teaching courses in nuclear processes, specifically neutron activation analysis and gamma spectroscopy. The Reactor Sharing Program supported the use of the Fast Flux Irradiation Device for multiple users at New Mexico Institute of Mining and Technology and the University of Nevada at Las Vegas. This device has near optimum neutron fluxes for 39Arf40Ar dating.

2.4 Commercial Activity and External Research The NSC provides services to a variety of users who provide their own funding. The majority of commercial activities relate producing radioactive tracers for the Texas petroleum and chemical industries. Another commercial activity uses the converted Thermal Column area to produce micropore filters used in ultra-pure water systems in the semiconductor industry.

Outside research grants fund a significant amount of the NSC's research. The NSC has many years of experience producing radioisotopes and has developed several customer-specific methods for radioactive sample production and handling. The production of radioisotopes generally involves handling radioactive material with high activities. The NSC staff takes precautions to minimize their exposures during the transfer of radioactive materials to shipping shields.

7

Texas A&M University System Nuclear Science Center Annual Report 2003

3.

Facility and Procedure Changes 3.1 Facility Modifications New Color Surveillance Monitors & Cameras were installed in December 2003. The electronic staff replaced the three monochrome monitors, in the control room, with two new color monitors.

The new monitors have a split screen option, allowing up to eight cameras being viewed simultaneously. The existing black & white cameras were replaced with color cameras, and more cameras were added in strategic locations.

3.2 Experiment Authorizations and Modifications There were no new experiment/modification authorizations initiated during the year 2003.

4. Reactor Maintenance and Surveillance 4.1. Scheduled Maintenance NSC personnel performed regular maintenance on the Fuel Element Temperature Channel, Area Radiation Monitors and the Linear, Log, and Safety Power Channels as required by the Technical Specifications. They also performed all surveillances required by the reactor license. Control rod worth and scram time measurements performed in August 2003 gave the following results. The total rod worth is $15.67. The most reactive control rod is Shim Safety #4 with a worth of $3.92.

The shutdown margin was $5.40 and core excess was $4.45. Scram times on all rods were less than 1.2 seconds. In addition, operators performed calorimetric calibration following each maintenance period, and fuel inspections with no abnormalities noted (as required by the Technical Specification). The cold critical reactivity worth, performed for each reactor experiment, shows the most reactive fixed experiment is the Fast Flux Pneumatic Receiver

(-$1.35) with leveling high boron loading the negative worth.

4.2 Unscheduled Maintenance Table 4-1: Unscheduled Maintenance 1/23/03 Safety Channel #2 meter reading pegged low when the magnet power was on. One of the Safety Cannel's detector cables was grounding to the bridge. The cable was repaired and the unit was returned to service.

1/23/03 Shim Safety 3 magnet was not holding and the controller was resetting to a wrong indication. The magnet wiring 8

Texas A&M University System Nuclear Science Center Annual Report 2003 and the controller logic circuit was renaired.

2/1/03 The Log Power drawer failed. A new pre-amp and an external power supply were installed and unit was returned to service.

2/20/03 The Up-Ramp Door was indicating open all of the time. The connections on the door switch were repaired.

3/15/03 The brass gear in the F.A.M. Channel 1 paper drive was replaced.

4/10/03 The South Core Light was replaced.

5/5/03 The wiring between the Beam Port 4 Cave door and the panel alarm was repaired after it failed to indicate an opened door.

10/9/03 An amplifier I.C. was replaced in the Control Room Intercom restoring communications with the front gate.

12/19/03 An I.C. was replaced in the Misc. Panel restoring proper indication of the Lower Research Level Access, in the Control Room.

4.3 Emergency Planning and Review The Reactor Safety Board completed their audits of the emergency and security plans in 2003.

The NSC staff and the Reactor Safety Board reviewed the NSC Security and Emergency Plans and audits at the August, 2003 board meeting. A successful facility wide emergency drill was conducted on December 16, 2003. Due to continuing concerns with terrorism consider review of the security plan was required during mid 2003. A set of compensatory security measure were submitted to the Nuclear Regulatory Commission for review and adoption. As of this date these measures are still in review.

4.4 Unscheduled Shutdowns There were six unscheduled reactor shutdowns during 2003. The causes are detailed below:

9

Texas A&M University System Nuclear Science Center Annual Report 2003 Table 4-2: Unscheduled Shutdowns 1/14/03 Reactor Scrammed due to anticipatory circuitry in Safety Channel #2 during startup next to the Thermal Column.

4/15/03 Reactor Scrammed due to loss of power from offsite.

6/11/03 Reactor Scrammed due to high power circuitry in Safety Channel from high neutron reflection while operating next to the Thermal Column.

6/13/03 Reactor Scrammed due to loss of power from offsite.

6/24/03 Reactor Scrammed due to loss of power from offsite.

9/03/03 Reactor Scrammed due to high power circuitry in Safety Channel from slight sample position fluctuations and high neutron reflection while operating next to the Thermal Column.

10

Texas A&M University System Nuclear Science Center Annual Report 2003

5.

Health Physics Surveillance The purpose of Health Physics surveillance is to ensure safe use of radioactive materials in Nuclear Science Center's (NSC) research and service activities and to fulfill the regulatory requirements of U.S. Nuclear Regulatory Commission and State agencies. The NSC maintains a Health Physics group as an integral part of the organization. They are responsible for chemical and physical safety concerns as well as radiological. The TAMU Environmental Health and Safety Department provides additional support to the NSC Health Physics group upon request.

5.1 Radioactive Shipments The Health Physics monitoring and technical support that was provided in 2003 assured minimal exposure during sample handling, shipment of radioactive material, and normal reactor operation. The radiation exposures were maintained ALARA. During 2003, about 342 radioactive samples were handled of which 304 were sent to various research facilities including Texas A&M University campus and the rest retained at the Nuclear Science Center facility. A total of 231 curies were handled in 2003.

5.2 Personnel Monitoring Personnel Monitoring was provided to approximately 71 personnel. All measured doses to personnel were below the limits set forth in 10 CFR 20. Five individuals received whole body dose greater than 10% of the annual limit inl 0 CFR 20. The doses recorded were 618, 717, 695, 779, and 571 mrem deep dose equivalent for the year. Airborne monitoring during sample handling continued to show no significant airborne activity. Therefore, total effective dose equivalent will equal deep dose equivalent for 2003. A total of 6.65 manrem was recorded for all of 2003. When total manrem/curie was determined for 2003, the dose per curie equaled 0.028.

During 2003, about 1164 visitors toured the Nuclear Science Center. Minimal exposures were measured with pocket ion chambers worn by these visitors and the pocket ion chamber readings of their respective tour guides.

NSC employees who were likely to exceed 10% of their total annual dose wore TLDs/film badges and extremity dosimeters that were provided by Landauer, a NVLAP accredited supplier.

Landauer also provided the analysis reports of the doses received.

5.3 Facility Monitoring Surveys of the Nuclear Science Center facilities were performed to assess radiological hazards to NSC workers. Radiation levels and sources of radioactive contamination were routinely monitored. Approximately 350 smear samples were collected and evaluated each month. All accessible areas at the NSC are surveyed for radiation and contamination levels monthly. Areas where contamination is expected, access / egress controls are in place and are evaluated on shorter intervals. Area monitors were placed at strategic locations in the reactor facility, this I1I

Texas A&M University System Nuclear Science Center Annual Report 2003 provides dose equivalent (mrem) on a monthly basis. The following table summarizes the annual accumulated dose equivalent (mrem) recorded on the area monitors for 2003.

Table 5-1. Total Dose Equivalent (mrem) Recorded on Area Monitors Monitor ID Location Accumulated Dose Equivalent (mrem)

BLDG MNTR 1 Upper Research Level 1239 Mezzanine BLDG MNTR 2 Lower Research Level 163 Mezzanine BLDG MNTR 3 Lower Research Level 88 AREA Control Room 194 AREA Upper Research Level 798 AREA Hand and Foot Monitor 2584 Room 5.4 Particulate Effluent Monitoring Radioactive particulates were monitored at the base of the central exhaust stack and summarized on a monthly basis. The annual average release concentration was 1.73E-11 pCi/cc. Total activity released for 2003 was 9.85E-04 Ci. The following table summarizes monthly particulate effluent releases during 2003.

Table 5-2. Monthly Particulate Effluent Releases 12

Texas A&M University System Nuclear Science Center Annual Report 2003 total:

1.82E+13 2.79E-04 April 2.22E-11 1.11E-13 6.12E+12 1.36E-04 May 2.90E-11 1.45E-13 6.32E+12 1.83E-04 June 2.72E-11 1.36E-13 6.12E+12 1.66E-04 Average:

2.61 E-11 1.30E-13 6.19E+12 1.62E-04 total:

1.86E+13 4.85E-04 July

<MDC

<MDC 6.32E+12

<MDC August 8.54E-12 4.27E-14 6.32E+12 5.40E-05 September 6.49E-12 3.25E-14 6.12E+12 3.97E-05 Averace:

7.52E-12 3.76E-14 6.25E+12 4.69E-05 total:

1.88E+1 3 9.37E-05 IV October

<MDC

<MDC 6.32E+12

<MDC November

<MDC

<MDC 6.12E+12

<MDC December 2.02E-11 1.01 E-13 6.32E+12 1.28E-04 Average:

2.02E-11 1.01 E-13 6.25E+12 1.28E-04 total:

1.88E+13 1.28E-04

-A e726834 1

n 5E 14- '6.2O397E+i21 0003255 notes:

1. Average Release Concentration data Form 805, Channel 1 - Activity Released
2. Diluted Concentration equal to Average Release Concentration multiplied by 0.005 (Technical Specification 3.5.2. dilution value for release concentration at exclusion boundary)
3. Exhaust Volume equal to: (# days/monthr( 24hrs/dayr( 60min/hr)'( 5000cfmy 3.53E-5cfmlcc)
4. Total Release equal to:(Average Release Concentration)( Exhaust volumer (1CIi 1 E6 uCi)

Minimum Detectable Concentration (MDC) 1.1 E-11 pCi/cc 5.5 Gaseous Effluent Monitoring Argon-41 is the major gaseous effluent produced and released at the Nuclear Science Center.

This effluent is monitored at the central exhaust stack. Total Argon41 released during 2003 was 5.25 Ci with an annual average release concentration of 7.01E-8 PiCi/cc and with a diluted concentration of 3.51E-10 pCi/cc.

The following table summarizes monthly gaseous effluent releases during 2003.

Table 5-3. Monthly Gaseous Effluent Releases 13

Texas A&M University System Nuclear Science Center Annual Report 2003 March 4.19E-08 2.1OE-10 6.32E+412 2.65E-01 Average: l 6.85E-08 l

3.42E-10 l 6.12E+12 4.21E-01 total:

1.82E+13 1.26E+00 Apri 6.26E-08 3.13E-10 6.12E+12 3.83E-01 May 7.OOE-09 3.50E-11 6.32E+12 4.43E-02 June 2.20E-08 1.1 OE-10 6.12E+12 1.35E-01 Average:

3.05E-08 1.53E-10 6.19E+12 1.87E-01 total:

1.86E+13 5.62E-01 IIl y

8.25E-08 4.13E-10 6.32E+12 5.22E-01 August 4.85E-08 2.43E-10 6.32E+12 3.07E-01 September 4.68E-08 2.34E-10 6.12E+12 2.86E-41 Average:

5.93E-08 2.96E-10 6.25E+12 3.72E-01 total:

1.88E+13 1.12E+O0 IV October 1.06E-07 5.31 E-10 6.32E+12 6.73E-01 November 4.93E-08 2.47E-10 6.12E+12 3.02E-01 December 2.11 E-07 1.05E-09 6.32E+1 2 1.33E+00 Average:

1.22E-07 6.11 E-10 6.32E+12 7.69E-01 total:

1.88E+13 2.31 E+00 l7ui...

8rge tg3'ii-¢:

-622E+12<

t,.4 W&

t ~i, l;iimmary]'.;l:E.ro.o notes:

1. Average Release Concentration data Form 805, Channel 3 "Activity Released
2. Diluted Concentration equal to Average Release Concentration multiplied by 0.005 (Technical Specification 3.5.2, dilution value for release concentration at exclusion boundary)
3. Exhaust Volume equal to: (# days/month)( 24hrs/day)-( 60minthr)-( 5000cfmy 3.53E-5cfmlcc)
4. Total Release equal to:(Average Release Concentration)'( Exhaust volume)' (1 CiY 1 E6 uCi)
  • Minimum Detectable Concentration (MDC) 1.1 E-07 IiCi/cc 5.6 Liquid Effluent Monitoring Radioactive Liquid effluents are maintained in collection tanks before release from the confines of the Nuclear Science Center. Sample activity concentrations and isotope identifications were determined before each release. There were 17 releases in 2003, totaling 5.29E+5 gallons including dilution. The total radioactivity released was 9.55E-04 Ci with an annual average concentration of 4.77E-07 pCi/cc.

Summaries of the release data are presented in the table below. Radioactivity concentrations for each isotope found were below the Effluent Concentration limits specified in 10 CFR 20, Appendix B. Some of the major radionuclides identified in the waste stream are Mn54, Sc46, Sb'24 and Co60.

14

Texas A&M University System Nuclear Science Center Annual Report 2003 Table 5-4. Monthly Liquid Effluent Releases Number of Releases Volume Released (cc)

Total Radioactivity (Ci)

Average Concentration (PCi/cc)

Quarter Month I

January February I

1.01 E+08 4.79 E-05 4.76 E-07 March 1

1.07 E+08 4.14 E-05 3.86 E-07 Quarter Total:

2 2.08 E+08 8.93 E-05 II April 2

1.89 E+08 2.25 E-04 1.19 E-06 May 2

2.79 E+08 9.63 E-05 3.45 E-07 June 1

2.55 E+08 2.46 E-05 9.65 E-08 Quarter Total:

5 7.23 E+08 3.45 E-04 III July 1

2.44 E+08 1.18 E-05 4.84 E-08 August 3

1.59 E+08 6.92 E-05 4.34 E-07 September 1

1.21 E+08 5.91 E-05 4.87 E-07 Quarter Total:

5 5.24 E+08 1.40 E-04 IV October 3

3.71 E+08 9.49 E-05 2.56 E-07 November 2

1.76 E+08 2.85 E-04 1.61 E-06 December Quarter Total:

5 5.47 E+08 3.80 E-04 Annual Total:

17 2.00 E+09 9.55 E-04 4.77 E-07 Summary I

I

  • No releases
6.

Environmental Monitoring In conjunction with representatives from the Texas Department of Health, Bureau of Radiation Control, a quarterly environmental survey is conducted to insure compliance with federal regulations. This program consists of TLD monitors located at various locations on the NSC site and two background monitors one located at 3.84 miles NW of facility and the other at 0.25 miles SE of facility. The collection, analysis, and evaluation of NSC creek sediment, and milk samples from the dairy downwind of the facility are also included in the program.

15

Texas A&M University System Nuclear Science Center Annual Report 2003 6.1 Environmental Samples The environmental samples were collected in accordance with the schedules of the cooperative surveillance program between the Texas Department of Health and the Texas A&M University.

NSC creek sediment and milk samples from the dairy were analyzed using an intrinsic germanium detection system for isotopic identification at the NSC. A second set of sediment and milk samples were analyzed by the Texas Department of Health for comparison.

The concentrations of environmental samples determined for each quarter are listed below.

Table 6-1. Environmental Sample Analysis MILK 2003 Quarter Sample Location Concentration (pCi/mL)-

TDH 1st TAMU Dairy

< 1.3 E-06 2nd TAMU Dairy closed out 3rd TAMU Dairy closed out 4 th TAMU Dairy closed out SEDIMENT (pCi/g)-NSC 1st NSC creek

<1.37E-06 2nd NSC creek

, <4.9 E-06 3rd NSC creek

<5.4 E-06 4th NSC creek

<7.6 E-06

  • Since the A&M dairy was closed, TDH no longer require NSC to submit milk samples.

6.2 Site Boundary Dose Rate The environmental survey program measures the integrated radiation exposures at the exclusion area boundaries. These measurements are made for periods of approximately 91 days using TLDs. Monthly measurements of direct gamma exposure rate in jirem/h are also made at each of the TLD locations. The dosimeters are provided and processed by Texas Department of Health (TDH), Bureau of Radiation Control, Division of Environmental Programs Total TLD dose is multiplied by the occupancy factor (1/16) to determine total deep dose to the general public.

To determine internal exposure to individuals outside the site area the EPA's approved code COMPLY was used. The exposure calculated via COMPLY was 0.077 mrem/yr. This exposure is added to the calculated total deep dose. This total is the dose received by the general public.

16

Texas A&M University System Nuclear Science Center Annual Report 2003 Table 6-2. Site Boundary Dose Rates Site Location Quarterly Exposure Rate TLD Deep Internal Total Dose Dose Dose Dose (mrem)

(rmldas(mremd)

(mrem) 2 300 ft. W of 4.0 2.8 3.5 3.2 13.5 0.84 0.077 0.92 reactor

building, near fence comer 3

250 ft W-SW 4.0 1.9 3.5 1.6 11 0.69 0.077 0.77 of reactor building, on SW chain link fence 4

200 ft NW of 8.1 5.6 8.3 8.0 30 1.9 0.077 1.98 reactor building, on chain link fence, near butane tank.

5 225 fit NE of 5.1 1.9 4.7 3.2 14.9 0.93 0.077 1.0 reactor building, on fence N of driveway 10 190 ft SE of 3.0 0.9 2.4 2.4 8.7 0.54 0.077 0.62 reactor

building, near fence comer 11 300 ft NE of 3.0 0.9 2.4 1.6 7.9 0.5 0.077 0.58 reactor
building, near fence comer 18 375 ftNE of 7.1 3.7 5.9 4.0 20.7 1.3 0.077 1.38 reactor building 17

Texas A&M University System Nuclear Science Center Annual Report 2003 19 320 ft NE of 4.0 3.7 4.7 2.4 14.8 0.93 0.077 1.0 reactor building 14 3.84 miles 0.0 0.9 2.4 0.8 4.1 0.26 0.077 0.34 NW of facility 23 0 25 miles 0.0 0.0 0.0 0.0 0.0 0.0 0.077 0.077 S E of facility

7.

Radioactive Waste Shipments During the year 2003 there was no solid waste released from the NSC for disposal offsite. But some solid waste stored for decay with short half-lives (<300 d) were segregated and sorted as non-radioactive.

8.

Reactor Safety Board The Reactor Safety Board is responsible for providing an independent review and audit of the safety aspects of the NSCR. The RSB meets at least once a year to review audit reports, security and emergency plans, new experiments and modifications to the facility.

Membership (2003)

Chairman/Licensee:

Dr. Kenneth Hall, Interim Deputy Director Texas Engineering Experiment Station Members:

Dr. John Ford, Assistant Professor Nuclear Engineering Department Dr. Marvin Adams, Associate Professor Nuclear Engineering Department Dr. William Dennis James, Research Chemist Chemistry Department 18

Texas A&M University System Nuclear Science Center Annual Report 2003 Dr. John Hardy, Professor Physics Department Dr. Teruki Kamon, Professor Physics Department Ex-Officio Members:

Dr. Warren Reece, Director Nuclear Science Center Dr. Latha Vasudevan, NSC RSO Nuclear Science Center Dr. William Burchill, Professor and Head Nuclear Engineering Department Mr. John Salsman, Assistant Director/RSO Environmental Health and Safety Department Mr. Robert Berry, Reactor Supervisor AGN201, Nuclear Engineering Department 19