Technical Specification Page for Amendment 221 to License DPR-51
ML040700938
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 03/02/2004
From:
NRC/NRR/DLPM
To:
References
Download: ML040700938 (1)


Text

CREVS 3.7.9 CONDITION REQUIRED ACTION COMPLETION TIME E. Two CREVS trains E.1 Suspend movement of Immediately inoperable during irradiated fuel assemblies.

movement of irradiated fuel assemblies.

F.

Two CREVS trains F.1 Enter LCO 3.0.3.

Immediately inoperable during MODE 1, 2, 3, or 4 for reasons other than Condition B.

SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.7.9.1 Operate each CREVS train for> 15 minutes.

31 days SR 3.7.9.2 Perform required CREVS filter testing in accordance In accordance with with the Ventilation Filter Testing Program (VFTP).

the VFTP SR 3.7.9.3 Verify the CREVS automatically isolates the Control 18 months Room and switches into a recirculation mode of operation on an actual or simulated actuation signal.

SR 3.7.9.4 Verify VSF-9 makeup flow rate is 2 300 and 18 months

< 366 cfm when supplying the control room with outside air.

SR 3.7.9.5 Verify 2VSF-9 makeup flow rate is 2 418.5 and 18 months

< 511.5 cfm when supplying the control room with outside air.

I ANO-1 3.7.9-2 Amendment No. Q+&, 221