L-04-029, Year 2003 Steam Generator Examination Reports

From kanterella
(Redirected from ML040700173)
Jump to navigation Jump to search

Year 2003 Steam Generator Examination Reports
ML040700173
Person / Time
Site: Beaver Valley
(DPR-066, NPF-073)
Issue date: 03/04/2004
From: Pearce L
FirstEnergy Nuclear Operating Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
L-04-029
Download: ML040700173 (174)


Text

FENOC Beaver Valley Power Station FENOCRoute 166 FirstEnergy Nuclear Operating Company Shippingport. PA 15077-0004 L IY'illianM Pearce 724-682-5234 Site Vice President Fax: 724-643-8069 March 4, 2004 L-04-029 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555-0001

Subject:

Beaver Valley Power Station, Unit No. 1 and No. 2 BV-1 Docket No. 50-334, License No. DPR-66 BV-2 Docket No. 50-412, License No. NPF-73 Year 2003 Steam Generator Examination Reports Enclosed is the Beaver Valley Power Station (BVPS) Unit No. 1 report describing the results of the steam generator eddy current examinations that occurred during the Unit No. 1 15th Refueling Outage (IR15 - March 2003). Also enclosed is the BVPS Unit No. 2 report describing the results of the steam generator eddy current examinations that occurred during the Unit No. 2 10th Refueling Outage (2R10 - September 2003). These reports satisfy Technical Specification 4.4.5.5.b in each Unit's respective Technical Specifications which require the submittal of the complete results of the steam generator tube and sleeve inservice inspection within 12 months following the completion of the inspection.

Summaries of the BVPS Unit 1 and Unit 2 steam generator inspections are contained in and Enclosure 2, respectively. The Enclosures are supported by attachments which provide the information listed below as required by Technical Specification 4.4.5.5.b:

a.

Number and extent of tubes and sleeves inspected

b.

Location and percent of wall-thickness penetration for each indication of an imperfection

c.

Identification of tubes plugged or repaired lists the definitions of terms used in the data reporting and data analysis process.

A 0`/

Beaver Valley Power Station, Unit No. 1 and No. 2 Year 2003 Steam Generator Examination Reports L-04-029 Page 2 No new commitments are contained in this submittal.

If there are any questions concerning this matter, please contact Mr. Larry R. Freeland, Manager, Regulatory Affairs/Performance Improvement at 724-682-5284.

Sincerely, L. William earce Enclosures c:

Mr. T. G. Colburn, NRR Senior Project Manager Mr. P. C. Cataldo, NRC Sr. Resident Inspector Mr. H. J. Miller, NRC Region I Administrator

FENOC FirstEnergy Nuclear Operating Company BEAVER VALLEY POWER STATION UNITS #1 AND #2 2003 ANNUAL STEAM GENERATOR EXAMINATION REPORT

ENCLOSURE 1 BEAVER VALLEY POWER STATION UNIT NO. 1 15TH REFUELING OUTAGE

ENCLOSURE 1 Beaver Valley Power Station Unit No. 1 15th Refueling Outage (Attachments I through 3A)

Procedures and Personnel The examinations and the analysis performed during the 15th Refueling Outage were in compliance with the Beaver Valley Power Station Unit #1 Technical Specifications, NRC Regulatory Guide 1.83, the EPRI PWR Steam Generator Examination Guidelines, Volume 1 (Rev. 5) and FENOC Procedure ISIEl-7 (Rev. 8), "Unit #1 Steam Generator Examination Guidelines". Personnel evaluating data were Qualified Data Analysts (QDA) in accordance with Appendix "G" of the EPRI PWR Steam Generator Guidelines.

All analysts were required to pass a site specific performance demonstration prior to analyzing the eddy current data from the current outage. All data underwent an independent second party review prior to final acceptance.

Eddy Current Examination One hundred percent of the in-service tubes in Rows 3 through 46 from Steam Generators IRC-E-1A, IRC-E-1B and IRC-E-IC were examined full length with bobbin coil probes. In-service tubes in Rows 1 and 2 were examined with bobbin coil probes to the upper most tube support plate in each leg. The U-bend regions of the tubes in Rows 1 and 2 were examined with single coil Plus Point probes.

In response to issues at a plant with similar model steam generators, one hundred percent of the U-bend region in Rows 3 through 46 were examined with single coil Plus Point probes. This included one hundred percent Plus Point examination of the AVB region.

One hundred percent of the hot leg top-of-tubesheet region was examined in each steam generator with Plus Point probes. Circumferential indications located at the top of the hot leg tubesheet were stabilized prior to removing the tube from service. In addition, a twenty percent random sample of the cold leg top-of-tubesheet region was examined in steam generator IRC-E-1A.

Per the requirements of Technical Specification Amendment No. 198 (Generic Letter 95-05) all distorted tube support plate signals (DSI's) with bobbin coil voltages > 2.00 volts were further evaluated with Plus Point probes. Signals > 2.00 volts, confirmed (detected) with Plus Point probes, were repaired by tube plugging. Signals < 2.00 volts were randomly sampled with Plus Point probes to confirm the morphology being observed remained axial Outside Diameter Stress Corrosion Cracking (ODSCC).

The following additional examinations were performed per Amendment No. 198:

One hundred percent of dents with bobbin coil voltages > 5.00 volts located at tube support plates were re-examined with Plus Point Probes. No indications were observed.

One hundred percent of tube support plate residual signals with amplitudes large enough to mask a 1.00 volt indication were re-examined with Plus Point probes in each steam generator. Confirmed residual signals > 1.00 volt were removed from service.

ENCLOSURE 1 (ConL)

Beaver Valley Power Station Unit No. 1 15th Refueling Outage (Attachments 1 through 3A)

Bulged Tubesheet Sleeve One tube in RC-E-1B that was sleeved at 1R13 with full length tubesheet sleeve would not permit the passage of an eddy current probe during the IR15 steam generator examination. This tube was removed from service by plugging. All other in-service sleeved tubes permitted passage of the appropriate eddy current probe and were successfully inspected by eddy current testing.

The cause for the collapsed sleeves is understood. This degradation mechanism is known as the "flow diode" or the "Obrigheim" effect and has occurred in sleeved joints at several other sites. Reasonable assumptions supporting this occurrence is the development of through wall degradation in the parent tube that can permit water to enter the crevice created between the parent tube and the sleeve or water leaking past the tube-to-sleeve hardroll interface. Water that enters the crevice while the plant is in a cold condition can become trapped when the plant heats up. The flow path created by the parent tube degradation or the hardroll interface can close during hot conditions thus prohibiting the water from exiting the crevice. The pressure created by the trapped water at hot conditions is sufficient to collapse the sleeve.

This condition has been evaluated for BV 1. The evaluation has recognized the potential for additional sleeves to collapse due to the flow diode effect and has concluded that the structural integrity of the sleeve weld and mechanical roll will not be jeopardized.

Axial Indications in Parent Tube Behind Tubesheet Sleeves Twenty-eight tubes that were sleeved at IR13 with full length tubesheet sleeves were found to have axial indications in the parent tube lower hard roll region. The parent tube indications are located approximately 1.0" up from the tube end and are coincident with the area where a tube plug was previously removed by the TIG relaxation process. These tubes were removed from service.

In-Situ Pressure Testing Six tubes were pressure tested (5100 psi max) based on the results of the eddy current examinations.

No indications of leakage were observed.

Examination Summary The following table summarizes the number of tubes examined, number of tube sleeves examined and the number of tubes removed from service. No sleeves were installed during 1R15.

1RC-E-IA 1 IRC-E-1B I 1RC-E-IC 1 TUBES EXAMINED (BOBBIN) 2726 2940 2960 TUBE SLEEVES EXAMINED 288 203 N/A TUBES REMOVED FROM SERVICE l 99 l

84 l

35

ENCLOSURE 1 (Cont.)

Beaver Valley Power Station Unit No. I 15th Refueling Outage (Attachments 1 through 3A)

Notes for tubes removed from service IR 15:

During secondary side visual inspections in IRC-E-1A, a gap was observed along the entire length of the blowdown pipe support-to-tubesheet weld. The cause of this condition was believed to be improper welding techniques utilized during initial fabrication of the generator. One tube (RI C45) in IRC-E-1A was administratively removed from service in the event that the unrestrained blowdown pipe end could move side-to side during plant operation. Other tubes that could be impacted from this motion were removed from service in previous outages for reasons unrelated to the blowdown pipe issue.

The results of the Unit 1 steam generator eddy current examinations are provided in the following Attachments: - A - - A - - A -

Beaver Valley Unit #1 IR15 S/G Examination Results IRC-E-IA Tubes with Indications Beaver Valley Unit #1 1R15 S/G Examination Results IRC-E-lA Tubes Removed From Service Beaver Valley Unit #1 IR15 S/G Examination Results IRC-E-1B Tubes with Indications Beaver Valley Unit #1 IR15 S/G Examination Results 1RC-E-IB Tubes Removed From Service Beaver Valley Unit #1 IR15 S/G Examination Results IRC-E-IC Tubes with Indications Beaver Valley Unit #t1 IR15 S/G Examination Results lRC-E-IC Tubes Removed From Service

ATTACHMENT 1 BEAVER VALLEY UNIT #1 1R15 S/G EXAMINATION RESULTS IRC-E-lA TUBES WITH INDICATIONS

Beaver Valley Unit #1 Page 1 of 54 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inchl Cr-Length Cr-Angle From To 1

1 DSI 0.50 75 P1 04H

-0.09 07H TEH 1

5 DSI 0.77 49 P1 01H

-0.12 07H TEH 1

7 DSI 0.64 51 P1 01H 0.00 07H TEH 1

7 DSI 0.61 75 P1 02H 0.00 07H TEH 1

16 DSI 0.55 48 P1 01H

-0.05 07H TEH 1

18 DSI 0.54 102 P1 01H

-0.03 07H TEH 1

18 DSI 1.17 55 P1 02H

-0.08 07H TEH 1

18 DSI 1.02 117 P1 03H

-0.11 07H TEH 1

19 DSI 0.76 56 P1 01H

-0.03 07H TEH 1

19 MAI 0.40 101 6

01H

-0.02 0.21 01H 01H 1

24 SCI 2.56 21 P2 07H 9.51 45 07C 07H 1

26 DSI 1.48 84 P1 01H

-0.06 07H TEH 1

26 DSI 0.56 76 P1 02H

-0.14 07H TEH 1

30 DSI 1.76 66 P1 01H

-0.20 07H TEH 1

30 DSI 1.29 159 P1 02H

-0.11 07H TEH 1

30 SPR 1.79 137 P1 02H 0.00 07H TEH 1

30 SAI 0.18 113 6

02H 0.09 0.34 02H 02H 1

41 DSI 0.79 99 P1 01H

-0.15 07H TEH 1

41 MAI 0.52 98 6

01H

-0.15 0.43 01H 01H 1

45 DSI 1.17 106 P1 01H

-0.18 07H TEH 1

45 DSI 0.76 115 P1 03H 0.15 07H TEH 1

49 DSI 0.53 42 P1 02H

-0.06 07H TEH 1

53 DSI 0.67 98 P1 01H

-0.18 07H TEH 1

59 DSI 0.61 53 P1 01H 0.03 07H TEH 1

59 DSI 0.76 92 P1 02H

-0.15 07H TEH 1

60 DSI 0.74 119 P1 01H

-0.18 07H TEH 1

60 DSI 0.59 45 P1 02H 0.00 07H TEH 1

61 DSI 0.87 61 P1 01H

-0.12 07H TEH 1

61 DSI 0.29 60 P1 02H

-0.03 07H TEH 1

62 DSI 0.33 54 P1 02H

-0.09 07H TEH 1

65 DSI 0.43 105 P1 01H 0.06 07H TEH 1

84 DSI 1.33 64 P1 03H 0.03 07H TEH 2

3 DSI 0.50 50 P1 01H

-0.03 07H TEH 2

3 DSI 0.38 45 P1 02H

-0.03 07H TEH 2

7 DSI 1.02 120 P1 02H

-0.09 07H TEH 2

10 DSI 1.23 172 P1 01H

-0.03 07H TEH 2

10 DSI 1.35 130 P1 02H

-0.17 07H TEH 2

11 DSI 0.37 90 P1 01H

-0.03 07H TEH 2

11 DSI 1.88 68 P1 02H

-0.12 07H TEH 2

11 DSI 0.24 90 P1 06H 0.00 07H TEH 2

14 DSI 0.55 37 P1 02H

-0.03 07H TEH 2

16 DSI 0.53 50 P1 01H 0.00 07H TEH 2

23 DSI 0.54 96 P1 01H

-0.20 07H TEH 2

23 SAI 0.20 94 6

01H 0.09 0.20 01H 01H 2

23 SAI 0.11 78 6

TSH 0.40 0.24 TSH TSH 2

24 DSI 1.90 63 P1 01H

-0.17 07H TEH 2

24 SAI 0.64 88 6

01H

-0.17 0.23 01H 01H 2

24 DSI 0.52 74 P1 02H

-0.03 07H TEH 2

27 DSI 1.28 33 P1 01H 0.06 07H TEH 2

27 SAI 0.39 87 6

01H 0.00 0.25 01H O1H 2

30 DSI 1.16 70 P1 01H

-0.14 07H TEH

Beaver Valley Unit #1 Page 2 of 54 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 2

33 DSI 0.54 43 P1 01H

-0.03 07H TEH 2

33 MAI 0.32 117 6

01H

-0.09 0.28 01H 01H 2

33 DSI 0.40 78 P1 03H 0.03 07H TEH 2

35 DSI 0.74 125 P1 01H

-0.15 07H TEH 2

36 DSI 0.92 72 P1 01H

-0.03 07H TEH 2

37 DSI 1.52 67 P1 011H

-0.18 07H TEH 2

38 DSI 0.77 66 P1 01H

-0.09 07H TEH 2

38 MAI 0.24 85 6

01H

-0.09 0.45 011H 01H 2

38 DSI 0.62 64 P1 02H

-0.09 07H TEH 2

40 DSI 1.24 68 P1 01H

-0.17 07H TEH 2

40 SAI 0.36 85 6

01H 0.00 0.32 01H 01H 2

44 DSI 1.47 61 P1 01H

-0.24 07H TEH 2

44 DSI 0.27 151 P1 03H 0.03 07H TEH 2

44 DSI 0.70 146 P1 04H

-0.20 07H TEH 2

45 DSI 0.55 87 P1 01H

-0.12 07H TEH 2

51 DSI 1.75 31 P1 01H 0.03 07H TEH 2

51 MAI 0.34 96 6

01H 0.00 0.53 01H 01H 2

52 DSI 0.45 77 P1 01H

-0.12 07H TEH 2

53 DSI 0.81 90 P1 011H 0.00 07H TEH 2

53 DSI 0.44 81 P1 02H

-0.06 07H TEH 2

53 DSI 0.63 152 P1 03H

-0.12 07H TEH 2

55 DSI 0.56 42 P1 02H

-0.03 07H TEH 2

60 DSI 0.71 39 P1 01H 0.00 07H TEH 2

61 SAI 1.04 9

6 TSH

-1.68 0.19 TSH TSH 2

62 DSI 0.85 53 P1 02H 0.18 07H TEH 2

62 SAI 0.30 73 6

02H

-0.26 0.19 02H 02H 2

65 DSI 0.85 93 P1 01H

-0.12 07H TEH 2

65 DSI 0.41 112 P1 02H

-0.06 07H TEH 2

68 DSI 1.52 103 P1 01H

-0.23 07H TEH 2

69 DSI 0.52 88 P1 01H 0.00 07H TEH 2

70 DSI 1.51 70 P1 02H

-0.14 07H TEH 2

74 DSI 0.54 101 P1 02H 0.03 07H TEH 2

80 DSI 0.81 131 P1 01H 0.17 07H TEH 2

80 DS1 0.99 92 P1 02H 0.12 07H TEH 2

84 DSI 0.43 86 P1 01H 0.03 07H TEH 2

84 DSI 0.24 64 P1 02H 0.00 07H TEH 2

84 DSI 0.40 66 P1 04H

-0.06 07H TEH 2

85 DSI 0.50 75 P1 03H

-0.09 07H TEH 2

86 DSI 0.80 100 P1 02H 0.06 07H TEH 2

87 DSI 0.80 61 P1 02H 0.00 07H TEH 2

92 DSI 0.66 83 P1 01H 0.00 07H TEH 2

93 PCT 1.63 119 25 P1 01C

-0.15 07C TEC 2

93 PCT 0.41 120 23 P1 02C

-0.02 07C TEC 3

3 DSI 0.71 125 P1 01H 0.03 07H TEH 3

3 DSI 0.91 103 P1 02H 0.03 07H TEH 3

7 DSI 0.81 90 P1 01H

-0.12 07H TEH 3

7 DSI 1.08 95 P1 02H

-0.09 07H TEH 3

9 DSI 0.56 127 P1 01H

-0.15 07H TEH 3

9 SAI 0.44 117 6

01H 0.00 0.50 01H 01H 3

9 DSI 0.36 46 P1 02H 0.00 07H TEH 3

10 DSI 1.09 116 P1 01H 0.14 07H TEH

Beaver Valley Unit #1 Page 3 of 54 1R15 S/G Examination Results 1RC-E-1A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 3

10 SCI 0.16 56 P2 TSH

-0.10 52 TSH TSH 3

11 DSI 0.79 110 P1 01H 0.03 07H TEH 3

11 DSI 1.20 86 P1 02H

-0.09 07H TEH 3

13 DSI 0.59 130 P1 01H

-0.23 07H TEH 3

13 SAI 0.38 110 6

01H

-0.20 0.25 01H 01H 3

14 DSI 0.39 60 P1 01H

-0.06 07H TEH 3

15 DSI 0.47 126 P1 01H 0.00 07H TEH 3

15 DSI 0.74 116 P1 02H

-0.20 07H TEH 3

15 MAI 0.32 105 6

02H 0.16 0.31 02H 02H 3

15 DSI 1.00 60 P1 03H 0.00 07H TEH 3

16 DSI 0.44 79 P1 03H 0.00 07H TEH 3

19 DSI 0.89 70 P1 02H

-0.09 07H TEH 3

25 DSI 0.62 35 P1 01H

-0.03 07H TEH 3

25 DSI 0.29 139 P1 02H

-0.03 07H TEH 3

26 DSI 1.91 100 P1 01H

-0.14 07H TEH 3

26 MAI 0.68 97 6

01H

-0.03 0.29 O1H 01H 3

29 DSI 1.08 52 P1 01H

-0.12 07H TEH 3

32 DSI 0.97 96 P1 01H 0.00 07H TEH 3

32 DSI 0.75 85 P1 02H 0.00 07H TEH 3

32 DSI 0.83 114 P1 03H 0.20 07H TEH 3

32 DSI 0.56 91 P1 04H

-0.06 07H TEH 3

32 MAI 0.28 70 6

04H

-0.13 0.26 04H 04H 3

32 DSI 0.80 121 P1 05H

-0.15 07H TEH 3

33 DSI 0.46 54 P1 01H 0.00 07H TEH 3

35 DSI 0.72 61 P1 01H

-0.09 07H TEH 3

36 DSI 1.21 61 P1 01H

-0.12 07H TEH 3

36 DSI 0.96 12 P1 03H

-0.06 07H TEH 3

36 SAI 0.22 91 6

03H

-0.06 0.27 03H 03H 3

36 DSI 0.19 89 P1 06H 0.00 07H TEH 3

44 DSI 0.55 110 P1 01H

-0.18 07H TEH 3

45 DSI 0.62 104 P1 01H -0.18 07H TEH 3

47 DSI 0.60 91 P1 01H 0.06 07H TEH 3

47 DSI 0.59 64 P1 02H

-0.09 07H TEH 3

47 MAI 0.23 94 6

02H

-0.06 0.44 02H 02H 3

47 DSI 0.63 126 P1 03H 0.12 07H TEH 3

48 DSI 0.41 94 P1 01H 0.00 07H TEH 3

48 DSI 0.33 67 P1 03H 0.00 07H TEH 3

51 DSI 0.52 51 P1 01H

-0.03 07H TEH 3

51 DSI 0.40 106 P1 03H 0.03 07H TEH 3

51 DSI 0.51 40 P1 06H

-0.06 07H TEH 3

55 DSI 1.15 110 P1 01H 0.00 07H TEH 3

55 DSI 0.94 61 P1 02H

-0.09 07H TEH 3

55 MAI 0.30 121 6

02H 0.00 0.66 02H 02H 3

58 DSI 1.03 77 P1 01H

-0.14 07H TEH 3

58 DSI 0.85 62 P1 02H 0.03 07H TEH 3

58 DSI 0.63 91 P1 04H

-0.14 07H TEH 3

63 DSI 0.70 59 P1 01H 0.00

.07H TEH 3

63 DSI 0.74 127 P1 02H

-0.20 07H TEH 3

63 DSI 0.38 108 P1 07H

-0.06 07H TEH 3

63 DSI 0.24 118 P1 07H 0.03 07H 06C 3

64 DSI 0.49 27 P1 02H 0.00 07H TEH

Beaver Valley Unit #1 Page 4 of 54 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 3

67 DSI 0.35 80 P1 01H

-0.03 07H TEH 3

67 DSI 0.64 81 P1 02H 0.17 07H TEH 3

70 DSI 0.58 92 P1 02H 0.11 07H TEH 3

73 DSI 0.32 80 P1 01H

-0.03 07H TEH 3

75 NOI 0.37 103 3

02C 8.96 07C TEC 3

75 SAI 1.34 87 2

05H 0.08 0.71 05H 05H 3

75 SPR 1.68 113 P1 05H 0.00 07H TEH 3

75 NQI 0.60 102 3

TSC 7.30 07C TEC 3

77 DSI 0.62 142 P1 02H 0.14 07H TEH 3

78 SPR 1.66 115 P1 02H 0.00 07H TEH 3

78 MAI 2.03 93 2

02H 0.24 0.45 02H.

02H 3

80 DSI 0.95 105 P1 02H 0.23 07H TEH 3

85 DSI 0.66 82 P1 01H 0.03 07H TEH 3

85 DSI 0.42 113 P1 02H 0.03 07H TEH 3

88 DSI 0.56 111 P1 03H

-0.12 07H TEH 3

93 PCT 0.54 123 10 P1 01C -0.07 07C TEC 3

94 DSI 0.59 51 P1 02H

-0.12 07H TEH 3

94 MAI 0.44 94 6

02H

-0.01 0.56 02H 02H 4

1 DSI 0.52 112 P1 01H 0.00 07H TEH 4

1 DSI 0.86 60 P1 05H

-0.03 07H TEH 4

3 DSI 0.85 138 P1 01H 0.09 07H TEH 4

5 DSI 1.14 43 P1 01H

-0.03 07H TEH 4

5 MAI 0.19 131 6

01H

-0.04 0.29 01H 01H 4

5 DSI 0.36 84 P1 02H 0.00 07H TEH 4

7 DSI 0.78 56 P1 01H

-0.06 07H TEH 4

7 DSI 0.62 52 P1 04H

-0.06 07H TEH 4

7 DSI 0.23 39 P1 05H

-0.06 07H TEH 4

9 DSI 1.01 97 P1 01H 0.00 07H TEH 4

9 MAI 0.42 92 6

01H 0.00 0.43 01H 01H 4

9 DSI 0.70 114 P1 02H

-0.15 07H TEH 4

10 DSI 0.79 95 P1 01H

-0.03 07H TEH 4

10 DSI 0.96 68 P1 02H

-0.09 07H TEH 4

11 DSI 0.73 32 P1 02H

-0.06 07H TEH 4

11 DSI 0.91 40 P1 03H

-0.15 07H TEH 4

14 DSI 0.47 125 P1 01H 0.03 07H TEH 4

14 DSI 0.69 59 P1 02H

-0.09 07H TEH 4

17 DSI 0.48 99 P1 01H 0.00 07H TEH 4

17 DSI 0.59 68 P1 02H 0.03 07H TEH 4

17 MAI 0.38 96 6

02H 0.03 0.31 02H 02H 4

18 DSI 0.59 99 P1 03H

-0.15 2SH TEC 4

18 DSI 0.42 111 P1 05H -0.02 2SH TEC 4

18 DSI 1.06 74 P1 06H 0.00 2SH TEC 4

18 DSI 0.17 44 P1 07C 0.06 2SH TEC 4

18 SAI 0.17 138 2

07C 0.00 0.58 07C 07H 4

18 DSI 0.33 138 P1 07H

-0.05 2SH TEC 4

18 MAI 0.12 108 2

07H

-0.03 0.33 07C 07H 4

19 DSI 0.66 101 P1 02H

-0.17 1SH TEC 4

19 SAI 0.59 101 2

02H 0.15 0.67 02H 02H 4

28 DSI 0.67 68 P1 01H

-0.05 07H TEH 4

33 DSI 1.22 85 P1 01H

-0.03 07H TEH 4

33 DSI 1.04 111 P1 02H

-0.14 07H TEH

Beaver Valley Unit #1 Page 5 of 54 1 R15 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 4

33 DSI 1.11 110 P1 03H

-0.20 07H TEH 4

45 DSI 1.46 63 P1 01H

-0.09 07H TEH 4

47 DSI 0.57 42 P1 01H

-0.03 07H TEH 4

47 DSI 0.52 36 P1 02H 0.00 07H TEH 4

50 DSI 0.55 39 P1 011H

-0.06 07H TEH 4

50 DSI 0.23 29 P1 02H

-0.09 07H TEH 4

53 DSI 1.47 54 P1 011H

-0.06 07H TEH 4

54 DSI 0.96 64 P1 01H

-0.12 07H TEH 4

55 DSI 0.65 87 P1 01H

-0.20 07H TEH 4

56 DSI 0.48 82 P1 02H

-0.09 07H TEH 4

57 DSI 0.57 81 P1 01H

-0.17 07H TEH 4

57 DSI 0.46 85 P1 03H

-0.09 07H TEH 4

59 DSI 0.42 44 P1 011H 0.03 07H TEH 4

59 DSI 0.32 114 P1 02H

-0.11 07H TEH 4

60 DSI 0.55 90 P1 01H

-0.09 07H TEH 4

60 MAI 0.50 92 6

01H

-0.04 0.33 01H 01H 4

60 DSI 0.73 50 P1 02H

-0.03 07H TEH 4

60 DSI 0.30 44 P1 05H 0.00 07H TEH 4

63 DSI 0.69 64 P1 02H 0.00 07H TEH 4

63 DSI 0.40 116 P1 03H

-0.03 07H TEH 4

64 DSI 1.22 95 P1 05H 0.00 2SH TEC 4

64 DS0 0.57 129 P1 06H 0.13 2SH TEC 4

65 DSI 0.91 67 P1 01H

-0.06 07H TEH 4

66 DSI 0.54 44 P1 01H 0.00 07H TEH 4

68 DSI 0.54 39 P1 01H

-0.09 07H TEH 4

68 DSI 0.51 139 P1 02H

-0.09 07H TEH 4

68 DSI 0.56 91 P1 04H

-0.11 07H TEH 4

68 MAI 0.27 84 6

04H

-0.16 0.25 04H 04H 4

70 DSI 0.39 53 P1 01H

-0.06 07H TEH 4

70 DSI 0.48 25 P1 04H

-0.09 07H TEH 4

72 DSI 0.63 118 P1 01H

-0.18 07H TEH 4

73 SAI 0.15 107 6

TSH

-0.26 0.17 TSH TSH 4

74 DSI 0.61 73 P1 01 H

-0.03 07H TEH 4

74 PVN 2.00 64 2

07H 4.87 07H 07H 4

75 DSI 0.52 41 P1 01H

-0.06 07H TEH 4

77 DSI 0.28 28 P1 01H

-0.06 07H TEH 4

85 DSI 0.67 130 P1 03H 0.00 07H TEH 4

85 MAI 0.17 89 6

03H 0.08 0.19 03H 03H 4

86 DSI 1.68 77 P1 02H 0.26 07H TEH 5

1 DSI 1.68 82 P1 011H 0.03 TEH TEC 5

1 PCT 0.54 127 3

P1 02C

-0.03 TEH TEC 5

1 VOL 0.55 110 6

02C 0.06 02C 02C 5

1 DSI 1.46 64 P1 03H 0.16 TEH TEC 5

1 DSI 0.77 74 P1 04H 0.16 TEH TEC 5

4 DSI 0.76 30 P1 01H

-0.03 TEH TEC 5

5 DSI 0.87 52 P1 01H 0.00 TEH TEC 5

5 NOI 0.48 74 3

01H 20.16 TEH TEC 5

5 NOI 0.83 111 3

04H 19.43 TEH TEC 5

8 DSI 0.73 47 P1 O1H 0.00 TEH TEC 5

8 DSI 0.81 59 P1 02H 0.02 TEH TEC 5

11 DSI 0.60 32 P1 01H 0.03 TEH TEC

Beaver Valley Unit #1 Page 6 of 54 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 5

11 DSI 1.19 33 P1 02H 0.03 TEH TEC 5

11 SAI 0.50 114 6

02H 0.00 0.59 02H 02H 5

13 DSI 0.57 51 P1 01H 0.00 TEH TEC 5

14 DSI 0.56 117 P1 01H 0.15 TEH TEC 5

14 DSI 0.66 77 P1 02H

-0.10 TEH TEC 5

16 DSI 1.02 72 P1 01H 0.05 TEH TEC 5

19 DSI 1.53 95 P1 01H 0.00 STH TEC 5

19 DSI 1.08 130 P1 02H

-0.17 STH TEC 5

19 DSI 0.25 128 P1 04H 0.07 STH TEC 5

19 SAI 0.58 59 2

04H 0.07 0.41 04H 04H 5

19 DSI 0.46 68 P1 07C 0.00 STH TEC 5

23 DSI 1.01 69 P1 01H 0.07 TEH TEC 5

25 DSI 0.71 55 P1 01H 0.02 STH TEC 5

25 DSI 0.62 102 P1 02H 0.00 STH TEC 5

32 DSI 1.12 82 P1 01H

-0.20 TEH TEC 5

32 DSI 0.49 74 P1 03H 0.05 TEH TEC 5

34 DSI 1.11 85 P1 O1H

-0.05 TEH TEC 5

34 DSI 0.82 149 P1 03H 0.27 TEH TEC 5

34 SAI 0.31 104 6

03H 0.12 0.42 03H 03H 5

40 DSI 1.64 80 P1 01H 0.00 TEH TEC 5

43, DSI 0.32 106 P1 01H 0.17 TEH TEC 5

43 DSI 0.89 49 P1 02H 0.05 TEH TEC 5

44 DSI 1.00 82 P1 01H

-0.07 TEH TEC 5

44 SPR 1.81 80 P1 01H 0.00 TEH TEC 5

44 MAI 0.61 86 6

01H -0.15 0.73 01H 01H 5

44 DSI 0.31 100 P1 02H 0.05 TEH TEC 5

47 DSI 0.34 96 P1 01H 0.12 TEH TEC 5

49 DSI 0.66 52 P1 02H 0.05 TEH TEC 5

51 DS) 1.71 82 P1 01H

-0.10 TEH TEC 5

52 DSI 0.24 183 P1 03H 0.00 TEH TEC 5

52 SAI 0.24 84 6

03H 0.02 0.40 03H 03H 5

52 SAI 0.25 94 6

03H 0.00 0.32 03H 03H 5

58 DSI 1.16 166 P1 02H 0.13 TEH TEC 5

59 DSI 0.54 70 P1 01H 0.10 TEH TEC 5

59 SAI 1.12 87 6

01H

-0.02 0.58 01H 01H 5

59 DSI 0.66 73 P1 02H 0.10 TEH TEC 5

60 DSI 0.52 141 P1 01H 0.20 TEH TEC 5

60 DSI 0.38 100 P1 02H 0.20 TEH TEC 5

60 SAI 0.24 106 6

02H 0.02 0.50 02H 02H 5

60 DSI 0.84 90 P1 04H

-0.10 TEH TEC 5

61 DSI 0.93 99 P1 01H 0.02 TEH TEC 5

62 DSI 0.76 94 P1 01H 0.05 TEH TEC 5

62 DSI 1.94 95 P1 02H 0.00 TEH TEC 5

63 NOI 0.56 110 3

06H 32.09 TEH TEC 5

66 DSI 0.58 71 P1 01H 0.00 TEH TEC 5

67 DSI 0.46 74 P1 02H 0.10 TEH TEC 5

67 MAI 0.20 106 6

02H

-0.32 0.62 02H 02H 5

69 DSI 0.34 23 P1 01H 0.02 TEH TEC 5

70 DSI 0.73 71 P1 01H 0.03 TEH TEC 5

71 DSI 0.27 46 P1 02H 0.02 TEH TEC 5

72 DSI 0.96 50 P1 01H 0.02 TEH TEC

Beaver Valley Unit #1 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Page 7 of 54 Row Col 5

72 5

73 5

73 5

73 5

74 5

74 5

76 5

76 5

79 5

79 5

80 5

82 5

86 5

86 5

87 5

90 5

91 5

91 5

91 5

91 5

92 5

94 6

1 6

1 6

1 6

1 6

1 6

2 6

2 6

2 6

2 6

5 6

5 6

5 6

6 6

6 6

6 6

6 6

6 6

6 6

9 6

9 6

9 6

11 6

12 6

12 6

12 6

12 6

12 6

12 6

12 Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To SAI 1.19 87 6

01H

-0.07 0.58 01H 01H DSI 1.80 99 P1 01H 0.10 TEH TEC DSI 0.89 90 P1 02H 0.20 TEH TEC NQI 0.37 111 3

03C 22.20 TEH TEC DSI 0.64 82 P1 01H 0.05 STH TEC DSI 1.11 94 P1 02H

-0.05 STH TEC DSI 0.72 87 P1 01H 0.10 STH TEC DSI 0.52 63 P1 02H 0.05 STH TEC DSI 1.41 60 P1 01H 0.23 TEH TEC DSI 0.30 97 P1 02H 0.00 TEH TEC DSI 1.14 107 P1 O1H

-0.12 TEH TEC DSI 0.42 61 P1 02H 0.05 TEH TEC DSI 0.58 84 P1 01H 0.03 TEH TEC DSI 1.28 75 P1 02H 0.20 TEH TEC DSI 0.52 36 P1 01H 0.00 TEH TEC DSI 0.64 54 P1 02H 0.10 TEH TEC DSI 0.77 47 P1 O1H 0.10 TEH TEC DSI 0.43 54 P1 02H 0.10 TEH TEC MAI 0.27 103 6

02H 0.08 0.50 02H 02H DSI 0.72 41 P1 04H 0.03 TEH TEC DSI 0.79 81 P1 04H

-0.05 TEH TEC PCT 0.32 132 0

P1 01C -0.08 TEH TEC DSI 0.83 99 P1 01H 0.21 TEH TEC PCT 0.84 143 0

P1 02C -0.08 TEH TEC VOL 0.29 125 6

02C 0.10 02C 02C PCT 0.73 104 37 P1 03C 0.16 TEH TEC VOL 0.47 104 6

03C 0.24 03C 03C DSI 0.48 46 P1 02H 0.03 TEH TEC DSI 0.61 77 P1 03H 0.05 TEH TEC DSI 0.41 98 P1 07C -0.05 TEH TEC SAI 0.10 85 2

07C -0.05 0.29 07C 07H DSI 1.17 52 P1 01H 0.00 TEH TEC DSI 0.82 36 P1 02H

-0.05 TEH TEC SCI 0.27 107 P2 TSH 0.06 82 TSH TSH DSI 0.62 58 P1 01H

-0.05 TEH TEC NOI 0.34 100 3

04C 39.56 TEH TEC DSI 0.29 25 P1 07C -0.05 TEH TEC SAI 0.10 126 2

07C 0.01 0.24 07C 07H DSI 0.95 48 P1 07H

-0.03 TEH TEC SAI 0.14 141 2

07H

-0.08 0.32 07C 07H DSI 0.61 86 P1 01H 0.05 TEH TEC DSI 0.95 126 P1 02H 0.24 TEH TEC DSI 0.72 130 P1 03H

-0.13 TEH TEC DSI 2.07 13 P1 02H 0.07 TEH TEC DSI 1.83 78 P1 01H 0.02 TEH TEC DSI 1.75 115 P1 02H 0.20 TEH TEC DSI 0.79 91 P1 03H

-0.15 TEH TEC NQI 0.57 91 3

04H 2.30 TEH TEC DSI 0.89 135 P1 04H

-0.18 TEH TEC SAI 0.15 98 6

04H 0.00 0.41 04H 05H NOI 0.54 106 3

05C 3.52 TEH TEC

Beaver Valley Unit #1 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Page 8 of 54 Row Col 6

12 6

12 6

12 6

12 6

15 6

15 6

15 6

15 6

17 6

17 6

17 6

20 6

20 6

20 6

20 6

20 6

22 6

22 6

22 6

23 6

23 6

24 6

29 6

29 6

35 6

44 6

44 6

44 6

50 6

50 6

51 6

51 6

54 6

54 6

54 6

55 6

55 6

57 6

57 6

57 6

57 6

57 6

58 6

58 6

58 6

58 6

59 6

59 6

59 6

65 6

65 Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To DSI 0.56 68 P1 05H 0.00 TEH TEC SAI 0.24 99 6

05H 0.00 0.27 04H 05H DSI 0.18 123 P1 07H 0.00 TEH TEC SAI 0.20 106 2

07H 0.00 0.65 07C 07H DSI 1.07 71 P1 01H 0.02 TEH TEC DSI 1.48 102 P1 02H

-0.12 TEH TEC DSI 0.45 46 P1 07H 0.03 TEH TEC SAI 0.07 126 2

07H 0.10 0.24 07C 07H DSI 0.67 51 P1 01H 0.15 TEH TEC SAI 0.35 102 6

01H

-0.12 0.50 TSH 01H NQI 0.21 87 3

TSH 39.50 TEH TEC DSI 0.35 92 P1 01H

-0.05 TEH TEC DSI 0.74 149 P1 02H

-0.15 TEH TEC SAI 0.13 111 6

02H 0.00 0.46 02H 02H DSI 0.52 118 P1 04H

-0.18 TEH TEC SAI 0.22 96 6

04H

-0.04 0.34 04H 04H DSI 1.28 50 P1 01H

-0.02 TEH TEC MAI 0.47 102 6

01H

-0.02 0.39 01H 01H DSI 0.76 101 P1 02H 0.05 TEH TEC DSI 0.76 65 P1 01H 0.07 TEH TEC DSI 0.88 115 P1 02H 0.05 TEH TEC DSI 1.03 55 P1 01H 0.05 TEH TEC DSI 1.68 65 P1 01H 0.05 TEH TEC MAI 0.24 99 6

01H 0.05 0.41 01H 01H DSI 1.28 87 P1 01H 0.00 TEH TEC DSI 0.70 81 P1 01H 0.07 TEH TEC DSI 0.94 50 P1 02H 0.07 TEH TEC SAI 0.44 109 6

02H

-0.07 0.49 02H 02H DSI 0.85 113 P1 01H

-0.12 TEH TEC DSI 0.43 113 P1 02H

-0.05 TEH TEC DSI 0.62 120 P1 02H

-0.15 TEH TEC SAI 0.19 82 6

02H

-0.23 0.34 02H 02H DSI 0.65 86 P1 01H

-0.07 TEH TEC MAI 0.37 98 6

01H

-0.11 0.61 01H 01H DSI 0.52 142 P1 02H

-0.07 TEH TEC DSI 0.63 95 P1 01H

-0.17 TEH TEC SAI 0.41 106 6

01H

-0.22 0.79 01H 01H DSI 1.23 24 P1 01H 0.00 TEH TEC MAI 0.30 103 6

01H 0.00 0.23 01H 01H DSI 0.54 165 P1 02H 0.28 TEH TEC SAI 0.20 96 6

02H 0.25 0.31 02H 02H SAI 0.13 104 6

02H

-0.19 0.34 02H 02H DSI 0.22 66 P1 01H 0.08 TEH TEC DSI 0.48 104 P1 02H

-0.03 TEH TEC DSI 0.70 121 P1 05H

-0.10 TEH TEC SAI 0.42 101 6

05H

-0.02 0.58 05H 05H DSI 0.44 79 P1 01H 0.10 TEH TEC DSI 0.65 76 P1 02H 0.12 TEH TEC SAI 0.27 88 6

02H

-0.02 0.33 02H 02H DSI 0.51 91 P1 01H 0.05 TEH TEC DSI 0.60 118 P1 02H 0.23 TEH TEC

Beaver Valley Unit #1 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Page 9 of 54 Row Col 6

67 6

67 6

69 6

69 6

69 6

69 6

70 6

70 6

70 6

70 6

70 6

70 6

70 6

70 6

71 6

71 6

73 6

75 6

76 6

86 6

86 6

86 6

87 6

92 6

94 6

94 6

94 7

1 7

2 7

2 7

3 7

3 7

4 7

4 7

4 7

5 7

5 7

5 7

7 7

7 7

7 7

7 7

7 7

7 7

10 7

10 7

10 7

11 7

11 7

11 7

11 Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To DSI 0.60 38 P1 02H 0.08 TEH TEC SAI 0.31 101 6

02H 0.17 0.53 02H 02H DSI 0.86 48 P1 011H 0.02 TEH TEC DSI 0.45 55 P1 02H 0.05 TEH TEC DSI 0.31 105 P1 04H 0.10 TEH TEC SAI 0.21 91 6

04H 0.03 0.41 04H 04H DSI 1.61 152 P1 01H 0.02 TEH TEC DSI 1.55 120 P1 02H 0.05 TEH TEC SAI 0.52 107 6

02H

-0.07 0.54 02H 02H DSI 1.37 124 P1 03H 0.10 TEH TEC SPR 2.82 162 P1 03H 0.00 TEH TEC SAI 0.50 86 6

03H

-0.22 0.24 03H 03H DNT 2.49 173 P1 06H 0.18 TEH TEC SAI 0.21 131 6

06H 0.04 0.28 06H 06H DSI 0.92 53 P1 01H

-0.05 STH TEC DSI 0.28 74 P1 02H 0.07 STH TEC SAI 0.14 72 6

TSH

-0.07 0.14 TSH TSH SAI 0.36 65 6

TSH

-0.03 0.19 TSH TSH DSI 1.47 78 P1 02H 0.00 STH TEC DSI 1.07 121 P1 01H 0.22 TEH TEC SPR 1.64 107 P1 01H 0.00 TEH TEC SAI 0.17 109 6

01H 0.14 0.21 01H 01H PSI 14.79 164 8

01H 0.00 TEH TEC DSI 0.41 56 P1 02H 0.02 TEH TEC DSI 0.81 154 P1 01H 0.22 TEH TEC SVI 0.19 117 6

011H 0.15 0.29 121 01H 01H PCT 0.49 147 0

P1 02C 0.00 TEH TEC DSI 0.77 126 P1 01H

-0.13 TEH TEC DSI 0.60 111 P1 01H 0.16 TEH TEC DSI 0.57 47 P1 04H 0.11 TEH TEC DSI 0.79 59 P1 011H 0.16 TEH TEC DSI 0.76 34 P1 02H 0.05 TEH TEC DSI 0.98 40 P1 01H 0.03 TEH TEC MAI 0.31 94 6

01H 0.01 0.50 01H 01H DSI 1.03 88 P1 02H

-0.03 TEH TEC DSI 0.72 112 P1 02H 0.13 TEH TEC DSI 0.95 111 P1 03H 0.05 TEH TEC SAI 0.37 70 6

03H 0.00 0.43 03H 03H DSI 0.41 80 P1 02H

-0.03 TEH TEC DSI 0.39 128 P1 03H 0.11 TEH TEC DSI 0.21 105 P1 07C

-0.11 TEH TEC MAI 0.18 121 2

07C

-0.24 0.29 07C 07H DSI 0.26 134 P1 07H

-0.03 TEH TEC SAI 0.12 70 2

07H

-0.16 0.29 07C 07H DSI 0.87 70 P1 011H 0.00 TEH TEC DSI 1.20 93 P1 02H 0.12 TEH TEC DSI 1.31 64 P1 03H

-0.02 TEH TEC DSI 1.57 67 P1 01H 0.05 TEH TEC DSI 0.60 41 P1 02H

-0.05 TEH TEC MAI 0.21 101 6

02H

-0.13 0.48 02H 02H DSI 0.65 94 P1 03H

-0.20 TEH TEC

Beaver Valley Unit #1 Page 10 of 54 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 7

11 DSI 0.51 55 P1 07H 0.05 TEH TEC 7

11 SAI 0.10 97 2

07H

-0.01 0.44 07C 07H 7

16 DSI 1.08 53 P1 011H 0.20 TEH TEC 7

16 DSI 0.97 76 P1 02H

-0.10 TEH TEC 7

16 SAI 0.44 87 6

02H

-0.10 0.41 02H 02H 7

18 DSI 1.36 73 P1 01H 0.00 TEH TEC 7

18 DSI 1.74 50 P1 02H 0.12 TEH TEC 7

18 MAI 0.94 96 6

02H

-0.04 0.50 02H 02H 7

18 DSI 0.39 37 P1 07H 0.00 TEH TEC 7

18 SAI 0.17 103 2

07H

-0.13 0.45 07C 07H 7

22 DSI 0.90 71 P1 02H 0.11 STH TEC 7

23 DSI 0.60 80 P1 01H 0.17 TEH TEC 7

24 DSI 0.92 91 P1 O1H 0.17 TEH TEC 7

27 DSI 0.94 53 P1 01H

-0.02 TEH TEC 7

27 DSI 0.20 128 P1 02H 0.05 TEH TEC 7

28 DSI 1.41 53 P1 01H

-0.05 TEH TEC 7

31 DSI 1.22 46 P1 01H 0.02 STH TEC 7

33 DSI 1.33 71 P1 01H 0.00 STH TEC 7

33 DSI 0.87 75 P1 02H 0.12 STH TEC 7

36 DSI 0.56 114 P1 01H

-0.17 STH TEC 7

36 MAI 1.05 111 2

01H 0.00 0.49 01H 011H 7

36 DSI 0.56 50 P1 02H 0.02 STH TEC 7

36 DSI 0.61 116 P1 03H 0.00 STH TEC 7

41 DSI 0.75 58 P1 011H 0.02 TEH TEC 7

53 DSI 0.51 54 P1 O1H 0.00 TEH TEC 7

53 DSI 0.56 62 P1 02H 0.10 TEH TEC 7

54 DSI 1.38 115 P1 01H

-0.07 TEH TEC 7

54 DSI 0.45 123 P1 02H 0.05 TEH TEC 7

54 DSI 0.39 75 P1 03H 0.07 TEH TEC 7

58 DSI 0.27 100 P1 02H 0.03 TEH TEC 7

60 DSI 0.86 106 P1 03H

-0.05 1SH TEC 7

60 DSI 0.49 114 P1 07H 0.07 1SH TEC 7

60 SAI 0.22 109 2

07H 0.05 0.41 07C 07H 7

65 DSI 0.89 110 P1 02H

-0.08 TEH TEC 7

65 DSI 0.37 104 P1 03H 0.08 TEH TEC 7

65 DSI 0.25 88 P1 05H

-0.03 TEH TEC 7

66 DSI 0.47 96 P1 011H

-0.10 TEH TEC 7

67 DSI 0.57 94 P1 01H 0.32 TEH TEC 7

67 MAI 0.43 98 6

O1H 0.06 0.52 01H 01H 7

67 DSI 0.24 152 P1 02H 0.03 TEH TEC 7

67 DSI 0.35 184 P1 03H

-0.03 TEH TEC 7

68 DSI 1.36 66 P1 01H 0.05 TEH TEC 7

68 DSI 1.13 95 P1 02H 0.18 TEH TEC 7

71 DSI 0.56 34 P1 02H 0.00 TEH TEC 7

71 DSI 0.59 102 P1 04H

-0.10 TEH TEC 7

71 DSI 0.46 36 P1 05H 0.02 TEH TEC 7

73 DSI 0.80 39 P1 01H 0.10 TEH TEC 7

74 DSI 0.52 45 P1 02H 0.10 TEH TEC 7

76 DSI 1.28 36 P1 01H 0.07 TEH TEC 7

76 MAI 0.34 98 6

01H 0.01 0.43 01H 01H 7

77 DSI 0.80 85 P1 01H 0.10 TEH TEC

Beaver Valley Unit #1 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Page 11 of 54 Row Col 7

80 7

80 7

80 7

80 7

81 7

82 7

82 7

84 7

86 7

87 7

88 7

90 7

90 7

94 8

4 8

4 8

4 8

4 8

5 8

5 8

5 8

5 8

5 8

5 8

5

.8 6

8 6

8 6

8 6

8 6

8 7

8 7

8 10 8

10 8

10 8

10 8

10 8

11 8

11 8

11 8

11 8

13 8

13 8

13 8

13 8

14 8

15 8

15 8

15 8

15 8

16 Ind Volts Phase %TW Chan Loc Inchi Cr-Length Cr-Angle From To DSI 2.07 71 P1 01H

-0.05 TEH TEC MAI 0.35 104 6

01H

-0.09 0.39 01H 01H DSI 0.58 58 P1 02H 0.02 TEH TEC MAI 0.61 94 6

02H

-0.08 0.43 02H 02H DSI 0.39 111 P1 01H 0.10 TEH TEC DSI 0.85 52 P1 02H 0.07 TEH TEC SAI 0.28 109 6

02H

-0.16 0.62 02H 02H DSI 0.83 36 P1 02H 0.12 TEH TEC DSI 0.93 52 P1 01H 0.10 TEH TEC DSI 0.80 45 P1 02H 0.10 TEH TEC DSI 0.85 40 P1 02H 0.02 TEH TEC DSI 0.67 60 P1 02H 0.00 TEH TEC MAI 0.68 91 6

02H

-0.11 0.41 02H 02H PCT 0.96 138 0

P1 01C -0.28 TEH TEC DSI 0.73 94 P1 01H 0.13 TEH TEC DSI 0.94 66 P1 02H 0.08 TEH TEC DSI 0.62 108 P1 04H 0.16 TEH TEC DSI 0.41 115 P1 05H 0.14 TEH TEC DSI 0.53 63 P1 01H 0.05 TEH TEC MAI 0.24 71 6

01H 0.01 0.45 01H 01H DSI 0.67 90 P1 02H 0.08 TEH TEC MAI 0.21 103 6

02H 0.01 0.55 02H 02H DSI 1.02 99 P1 03H 0.11 TEH TEC DSI 0.68 48 P1 04H 0.14 TEH TEC DSI 0.66 77 P1 05H 0.00 TEH TEC DSI 0.93 48 P1 01H 0.00 TEH TEC MAI 0.62 96 6

01H 0.02 0.65 01H 01H DSI 1.21 67 P1 02H 0.03 TEH TEC SAI 0.63 92 6

02H 0.00 0.54 02H 02H DSI 0.41 99 P1 04H 0.08 TEH TEC DSI 0.93 46 P1 01H 0.00 TEH TEC MAI 0.24 98 6

01H 0.01 0.52 01H 01H DSI 0.69 63 P1 01H 0.08 TEH TEC DSI 0.98 27 P1 03H 0.03 TEH TEC SAI 0.23 83 6

03H 0.00 0.38 03H 03H DSI 0.11 92 P1 07H 0.00 TEH TEC SAI 0.11 106 2

07H

-0.15 0.15 07C 07H DSI 0.82 51 P1 01H 0.03 TEH TEC DSI 1.09 49 P1 02H 0.00 TEH TEC MAI 0.35 88 6

02H 0.00 0.47 02H 02H DSI 0.87 37 P1 03H 0.05 TEH TEC DSI 0.79 52 P1 01H 0.03 TEH TEC MAI 0.31 98 6

01H 0.00 0.45 01H 01H DSI 1.10 28 P1 02H 0.05 TEH TEC MAI 0.31 106 6

02H 0.01 0.43 02H 02H DSI 0.50 100 P1 01H 0.10 TEH TEC DSI 1.12 36 P1 01H 0.05 TEH TEC MAI 0.29 110 6

01H

-0.05 0.45 01H 01H DSI 1.00 14 P1 03H 0.05 TEH TEC SAI 0.18 86 6

03H 0.01 0.38 03H 03H DSI 0.64 75 P1 01H 0.17 TEH TEC

Beaver Valley Unit #1 Page 12 of 54 1 R15 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inchl Cr-Length Cr-Angle From To 8

20 DSI 0.40 64 P1 02H 0.05 TEH TEC 8

22 DSI 0.63 63 P1 02H 0.00 TEH TEC 8

23 DSI 0.81 34 P1 01H 0.00 TEH TEC 8

25 DSI 0.69 30 P1 01H 0.02 TEH TEC 8

25 DSI 0.80 98 P1 04H

-0.15 TEH TEC 8

25 SAI 0.33 98 6

04H

-0.11 0.14 04H 04H 8

26 DSI 0.64 88 P1 03H

-0.18 2SH TEC 8

26 SAI 0.98 92 2

03H

-0.17 0.34 03H 03H 8

26 NQI 0.33 130 3

04C 12.86 2SH TEC 8

26 DSI 0.98 69 P1 04H 0.00 2SH TEC 8

26 NQI 0.51 92 3

06C 16.38 2SH TEC 8

27 NOI 0.12 126 P1 TSH 1.34 TEH TEC 8

28 DSI 0.43 64 P1 01H 0.07 STH TEC 8

39 SAI 0.35 114 6

TSH 0.58 0.52 TSH TSH 8

41 DSI 0.76 86 P1 O1H 0.05 STH TEC 8

41 MAI 0.47 92 2

01H 0.23 0.68 01H 01H 8

41 DSI 1.07 134 P1 02H

-0.15 STH TEC 8

41 SPR 2.30 103 P1 02H 0.00 STH TEC 8

41 MAI 0.67 115 2

02H 0.20 0.62 02H 02H 8

41 DSI 1.45 166 P1 03H

-0.20 STH TEC 8

41 SAI 0.46 119 2

03H

-0.10 0.63 03H 03H 8

45 DSI 0.31 83 P1 03H 0.07 TEH TEC 8

47 DSI 0.50 129 P1 03H 0.07 TEH TEC 8

48 DSI 0.39 103 P1 01H 0.05 TEH TEC 8

49 DSI 0.89 70 P1 01H

-0.17 TEH TEC 8

52 DSI 1.05 139 P1 01H

-0.10 TEH TEC 8

52 DSI 1.01 79 P1 02H

-0.15 TEH TEC 8

53 DSI 0.40 102 P1 01H 0.00 TEH TEC 8

53 NQI 0.39 84 3

04C 17.51 TEH TEC 8

53 NOI 0.49 119 3

TSC 23.50 TEH TEC 8

55 DSI 0.86 115 P1 01H

-0.10 TEH TEC 8

55 DSI 0.59 87 P1 02H

-0.08 TEH TEC 8

59 DSI 0.43 56 P1 02H 0.00 TEH TEC 8

60 DSI 0.91 64 P1 01H 0.00 TEH TEC 8

61 DSI 0.55 54 P1 01H 0.12 TEH TEC 8

61 SAI 0.42 101 6

01H

-0.05 0.55 O1H 01H 8

61 DSI 0.52 26 P1 02H 0.03 TEH TEC 8

65 DSI 0.39 60 P1 01H 0.10 TEH TEC 8

65 DSI 1.17 41 P1 02H 0.03 TEH TEC 8

65 SAI 0.25 86 6

02H 0.07 0.31 02H 02H 8

66 DSI 0.29 150 P1 02H

-0.02 TEH TEC 8

68 DSI 1.07 101 P1 O1H 0.03 TEH TEC 8

68 DSI 0.53 62 P1 02H 0.05 TEH TEC 8

68 SAI 0.47 94 6

02H

-0.07 0.60

. 02H 02H 8

68 DSI 0.34 80 P1 04H 0.05 TEH TEC 8

71 DSI 0.80 33 P1 01H 0.05 TEH TEC 8

71 MAI 0.32 97 6

01H 0.00 0.48 O1H 01H 8

71 DSI 0.49 125 P1 03H 0.20 TEH TEC 8

71 SAI 0.22 90 6

03H 0.13 0.41 03H 03H 8

72 DSI 0.32 37 P1 O1H

-0.02 TEH TEC 8

72 SAI 0.17 110 6

01H

-0.26 0.31 01H 01H

Beaver Valley Unit #1 1 R15 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Page 13 of 54 Row Col 8

72 8

72 8

72 8

75 8

75 8

75 8

76 8

76 8

76 8

76 8

77 8

80 8

84 8

84 8

90 8

90 8

93 9

2 9

2 9

3 9

3 9

4 9

7 9

7 9

7 9

8 9

10 9

11 9

11 9

11 9

11 9

14 9

14 9

15 9

16 9

16 9

17 9

17 9

17 9

18 9

18 9

21 9

21 9

32 9

32 9

32 9

33 9

36 9

36 9

36 9

38 Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To DSI 0.61 80 P1 02H 0.00 TEH TEC DSI 0.77 96 P1 03H

-0.13 TEH TEC DSI 0.88 60 P1 05H 0.13 TEH TEC DSI 0.86 94 P1 01H

-0.12 TEH TEC MAI 0.27 85 6

01H

-0.14 0.41 01H 01H DSI 0.74 60 P1 02H 0.03 TEH TEC DSI 1.92 76 P1 01H 0.15 TEH TEC DSI 1.19 105 P1 02H 0.27 TEH TEC SPR 1.58 111 P1 02H 0.00 TEH TEC SAI 0.40 70 6

02H 0.07 0.72 02H 02H DSI 0.57 133 P1 01H

-0.07 TEH TEC DSI 1.33 63 P1 01H 0.05 TEH TEC PSI 15.00 165 8

01H 0.00 TEH TEC DSI 0.80 75 P1 03H 0.05 TEH TEC DSI 0.62 69 P1 02H 0.03 TEH TEC DSI 0.44 68 P1 03H 0.05 TEH TEC DSI 0.40 127 P1 01H 0.17 TEH TEC PCT 0.52 0

30 3

02C 0.03 02C 02C VOL 0.15 71 3

02C

-0.03 02C 02C NOI 0.57 114 3

03C 26.58 TEH TEC NOI 0.78 106 3

04H 20.07 TEH TEC DSI 0.75 44 P1 02H 0.05 TEH TEC DSI 0.90 44 P1 01H 0.08 TEH TEC DSI 1.12 48 P1 02H

-0.08 TEH TEC MAI 0.24 101 6

02H 0.00 0.59 02H 02H DSI 1.05 102 P1 02H 0.13 TEH TEC DSI 0.87 54 P1 03H

-0.05 TEH TEC DSI 0.23 64 P1 01H 0.03 TEH TEC DSI 0.33 87 P1 02H

-0.16 TEH TEC SAI 0.22 101 6

02H 0.00 0.41 02H 02H DSI 0.39 105 P1 03H 0.13 TEH TEC DSI 0.61 53 P1 01H 0.10 TEH TEC DSI 0.54 32 P1 02H 0.00 TEH TEC DSI 1.39 55 P1 01H 0.08 TEH TEC DSI 1.90 108 P1 01H

-0.02 TEH TEC DSI 1.02 125 P1 02H

-0.05 TEH TEC DSI 1.06 70 P1 O1H 0.02 TEH TEC DSI 0.85 17 P1 02H 0.00 TEH TEC SAI 0.21 106 6

02H

-0.12 0.36 02H 02H DSI 0.52 53 P1 01H 0.10 TEH TEC DSI 0.68 27 P1 02H

-0.02 TEH TEC DSI 0.93 75 P1 01H

-0.07 TEH TEC DSI 0.73 96 P1 03H 0.28 TEH TEC NOI 0.19 93 3

01C 15.06 1SH TEC DSI 0.55 52 P1 02H 0.05 1SH TEC NQI 0.74 111 3

06C 14.06 1SH TEC DSI 1.28 93 P1 01H

-0.11 STH TEC DSI 1.09 100 P1 02H

-0.21 1SH TEC SPR 2.12 116 P1 02H 0.00 1SH TEC MAI 0.39 95 2

02H

-0.11 0.71 02H 02H DSI 1.03 97 P1 01H 0.00 STH TEC

Beaver Valley Unit #1 Page 14 of 54 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 9

38 SAI 0.96 100 2

02H

-0.05 0.51 02H 02H 9

38 SPR 1.80 118 P1 04H 0.00 STH TEC 9

38 SAI 0.73 106 2

04H 0.26 0.26 04H 04H 9

44 DSI 0.44 124 P1 01H 0.00 STH TEC 9

46 DSI 0.53 111 P1 01H 0.05 STH TEC 9

49 DSI 0.48 75 P1 01H 0.07 TEH TEC 9

49 DSI 0.73 71 P1 obH

-0.07 TEH TEC 9

49 SAI 0.36 88 6

03H

-0.04 0.50 03H 03H 9

51 DSI 0.65 88 P1 01H

-0.15 TEH TEC 9

52 DSI 0.47 65 P1 01H 0.02 TEH TEC 9

52 MAI 0.43 93 6

01H 0.06 0.52 O1H 01H 9

53 NOI 0.36 119 3

04H 29.38 TEH TEC 9

53 NOI 0.33 105 3

TSC 18.86 TEH TEC 9

54 DSI 0.78 97 P1 02H 0.02 TEH TEC 9

55 DSI 0.74 77 P1 01H

-0.15 TEH TEC 9

55 NOI 0.41 108 3

03C 18.32 TEH TEC 9

56 DSI 0.49 62 P1 02H 0.15 TEH TEC 9

57 DSI 0.70 89 P1 01H

-0.15 TEH TEC 9

57 DSI 0.71 82 P1 02H 0.10 TEH TEC 9

57 NQI 0.29 115 3

06H 23.57 TEH TEC 9

62 DSI 0.69 80 P1 01H

-0.02 TEH TEC 9

62 MAI 0.37 106 6

01H

-0.10 0.35 01H 01H 9

65 DSI 0.90 50 P1 O1H 0.03 TEH TEC 9

68 DSI 0.51 108 P1 01H 0.02 TEH TEC 9

68 DSI 0.74 78 P1 02H 0.22 TEH TEC 9

69 DSI 0.62 59 P1 01H

-0.02 TEH TEC 9

73 DSI 0.48 99 P1 02H 0.27 TEH TEC 9

73 SAI 0.17 131 6

TSH 0.00 0.15 TSH TSH 9

74 DSI 1.26 99 P1 02H 0.32 1SH TEC 9

74 SPR 1.92 86 P1 02H 0.00 1SH TEC 9

74 SAI 0.78 88 2

02H 0.22 0.24 02H 02H 9

75 DSI 0.99 38 P1 01H 0.07 TEH TEC 9

75 MAI 0.48 93 6

01H 0.00 0.56 01H 01H 9

75 DSI 0.73 35 P1 04H 0.07 TEH TEC 9

76 DSI 0.25 12 P1 02H 0.08 TEH TEC 9

76 DSI 0.59 87 P1 03H 0.00 TEH TEC 9

78 DSI 0.44 85 P1 01H 0.07 TEH TEC 9

82 DSI 0.69 107 P1 01H

-0.07 TEH TEC 9

83 DSI 0.73 87 P1 01H 0.08 TEH TEC 9

83 DSI 1.02 86 P1 04H 0.35 TEH TEC 9

83 SPR 1.72 100 P1 04H 0.00 TEH TEC 9

83 SAI 0.26 91 6

04H

-0.06 0.50 04H 04H 9

84 DSI 0.87 102 P1 03H

-0.07 TEH TEC 9

85 DSI 0.86 145 P1 01H 0.20 TEH TEC 9

85 SAI 0.29 79 6

01H 0.14 0.43 01H 01H 9

85 DSI 0.89 82 P1 03H

-0.08 TEH TEC 9

85 SAI 0.28 86 6

03H 0.22 0.22 03H 03H 9

85 DSI 0.72 87 P1 04H 0.08 TEH TEC 9

86 DSI 0.71 105 P1 01H

-0.07 TEH TEC 9

86 DSI 1.36 78 P1 02H 0.12 TEH TEC 9

86 DSI 2.08 111 P1 04H 0.02 TEH TEC

Beaver Valley Unit #1 Page 15 of 54 1 R15 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 9

86 MAI 0.62 95 6

04H

-0.11 0.41 04H 04H 9

86 DSI 0.31 161 P1 05H 0.05 TEH TEC 9

86 DSI 0.68 95 P1 07C 0.05 TEH TEC 9

86 SAI 0.22 103 6

07C 0.16 0.31 07C 07C 9

86 SAI 0.16 139 2

07C 0.11 0.19 07C 07H 9

88 DSI 1.41 63 P1 02H 0.10 TEH TEC 9

88 DSI 0.48 56 P1 04H

-0.02 TEH TEC 9

88 DSI 0.62 73 P1 05H 0.05 TEH TEC 9

90 DSI 0.42 110 P1 02H 0.17 TEH TEC 9

90 DSI 0.71 91 P1 03H

-0.10 TEH TEC 9

90 SAI 0.35 89 6

03H 0.07 0.41 03H 03H 9

92 DSI 0.93 114 P1 02H 0.25 TEH TEC 10 2

PCT 0.86 141 0

P1 02C -0.16 TEH TEC 10 3

DSI 1.15 78 P1 01H

-0.03 TEH TEC 10 3

PCT 0.61 140 0

P1 02C -0.08 TEH TEC 10 4

DSI 1.38 76 P1 01H 0.21 TEH TEC 10 4

DSI 1.02 50 P1 02H 0.05 TEH TEC 10 4

SAI 0.40 113 6

02H 0.01 0.45 02H 02H 10 6

DSI 0.39 86 P1 04H 0.03 TEH TEC 10 6

DSI 0.41 81 P1 05H 0.08 TEH TEC 10 7

DSI 1.37 85 P1 01H 0.00 TEH TEC 10 7

DSI 1.03 92 P1 02H 0.00 TEH TEC 10 7

DSI 0.54 84 P1 04H 0.10 TEH TEC 10 8

DSi 0.77 72 P1 01H 0.00 TEH TEC 10 8

DSI 0.39 69 P1 02H 0.03 TEH TEC 10 8

DSI 0.59 38 P1 03H 0.03 TEH TEC 10 9

DSI 0.87 50 P1 01H 0.13 TEH TEC 10 9

DSI 0.47 80 P1 03H 0.16 TEH TEC 10 10 DSI 1.29 53 P1 01H 0.08 TEH TEC 10 10 DSI 0.84 81 P1 03H

-0.03 TEH TEC 10 11 DSI 1.43 105 P1 01H 0.05 TEH TEC 10 11 DSI 1.06 78 P1 02H

-0.11 TEH TEC 10 12 DSI 0.50 32 P1 01H

-0.03 TEH TEC 10 13 DSI 0.72 18 P1 02H 0.05 TEH TEC 10 13 NOI 0.82 123 3

03C 13.59 TEH TEC 10 15 DSI 1.08 61 P1 01H 0.08 TEH TEC 10 15 SAI 0.57 114 6

01H

-0.01 0.45 01H 01H 10 15 DSI 0.93 113 P1 02H

-0.05 TEH TEC 10 15 MAI 0.43 98 6

02H

-0.01 0.56 02H 02H 10 16 DSI 1.38 72 P1 01H 0.02 TEH TEC 10 16 DSI 1.34 36 P1 02H 0.00 TEH TEC 10 16 DSI 1.33 66 P1 03H

-0.05 TEH TEC 10 17 DSI 1.60 84 P1 02H

-0.08 1SH TEC 10 17 DSI 0.79 125 P1 04H 0.03 1SH TEC 10 17 DSI 0.49 85 P1 06H 0.11 1SH TEC 10 18 DSI 1.98 76 P1 01H 0.00 TEH TEC 10 18 DSI 0.83 58 P1 02H

-0.10 TEH TEC 10 19 DSI 0.59 21 P1 01H 0.05 TEH TEC 10 20 DSI 0.57 130 P1 01H

-0.20 TEH TEC 10 20 SAI 0.11 94 6

01H

-0.10 0.17 01H 01H 10 21 DSI 0.63 74 P1 O1H 0.00 TEH TEC

Beaver Valley Unit #1 Page 16 of 54 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 10 21 SAI 0.23 74 6

01H 0.00 0.21 01H 01H 10 21 DSI 0.93 46 P1 03H 0.03 TEH TEC 10 22 DSI 0.64 51 P1 02H 0.00 TEH TEC 10 22 SAI 0.21 111 6

02H

-0.02 0.20 02H 02H 10 23 DSI 1.56 69 P1 01H 0.05 TEH TEC 10 32 SPR 1.92 142 P1 02H 0.00 1SH TEC 10 32 SAI 0.34 125 1

02H 0.01 0.40 02H 02H 10 32 MAI 1.07 87 2

03H

-0.01 0.72 03H 03H 10 38 DSI 0.75 93 P1 01H 0.05 STH TEC 10 40 DSI 1.98 100 P1 01H

-0.16 STH TEC 10 40 DSI 0.94 109 P1 02H

-0.05 STH TEC 10 40 SAI 0.58 115 2

02H 0.00 0.24 02H 02H 10 40 DSI 0.37 97 P1 07C -0.03 STH TEC 10 41 DSI 0.45 72 P1 04H 0.03 2SH TEC 10 45 DSI 0.94 103 P1 01H

-0.16 STH TEC 10 47 DSI 0.94 91 P1 01H

-0.16 STH TEC 10 52 DSI 1.61 93 P1 02H

-0.14 1SH TEC 10 55 DSI 0.83 75 P1 01H

-0.12 TEH TEC 10 55 DSI 0.63 67 P1 02H 0.00 TEH TEC 10 57 DSI 1.96 52 P1 01H

-0.02 TEH TEC 10 62 DSI 0.69 33 P1 01H 0.00 TEH TEC 10 63 DSI 0.99 65 P1 01H

-0.07 TEH TEC 10 66 DSI 2.23 91 P1 01H 0.05 TEH TEC 10 66 MAI 2.74 34 6

01H

-0.02 0.50 01H 01H 10 66 DSI 0.98 110 P1 02H

-0.15 TEH TEC 10 68 DSI 0.55 33 P1 01H 0.07 TEH TEC 10 68 DSI 0.61 31 P1 02H 0.07 TEH TEC 10 69 DSI 0.56 139 P1 01H

-0.05 TEH TEC 10 69 DSI 0.35 76 P1 02H 0.10 TEH TEC 10 72 DSI 0.80 39 P1 01H 0.10 TEH TEC 10 72 DSI 1.18 33 P1 02H 0.15 TEH TEC 10 72 SAI 0.17 107 6

02H 0.15 0.36 02H 02H 10 72 DSI 0.40 44 P1 05H 0.05 TEH TEC 10 73 DSI 1.24 45 P1 01H 0.05 TEH TEC 10 73 SAI 0.26 113 6

01H 0.05 0.27 01H 01H 10 74 DSI 0.32 43 P1 01H 0.12 TEH TEC 10 75 DSI 0.60 48 P1 01H

-0.02 TEH TEC 10 76 DSI 1.04 37 P1 01H 0.00 TEH TEC 10 76 MAI 0.17 106 6

01H 0.01 0.23 01H 01H 10 77 DSI 0.39 70 P1 01H 0.07 TEH TEC 10 77 SAI 0.32 99 6

01H 0.05 0.54 01H 01H 10 77 DSI 0.71 133 P1 03H

-0.12 TEH TEC 10 77 SAI 0.16 105 6

03H 0.11 0.31 03H 03H 10 80 DSI 0.38 78 P1 02H 0.10 TEH TEC 10 81 DSI 0.29 82 P1 02H 0.03 TEH TEC 10 90 DSI 0.66 66 P1 02H 0.10 TEH TEC 10 92 PCT 0.60 134 0

P1 01C

-0.12 TEH TEC 11 4

PCT 0.37 0

25 3

01C

-0.09 01C 01C 11 4

VOL 0.39 61 3

01C -0.14 01C 01C 11 4

DSI 0.74 70 P1 01H 0.08 TEH TEC 11 4

DSI 0.69 43 P1 03H 0.03 TEH TEC

Beaver Valley Unit #1 Page 17 of 54 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 11 6

DSI 0.52 156 P1 02H 0.13 TEH TEC 11 8

DSI 0.56 60 P1 01H 0.11 TEH TEC 11 10 DSI 0.43 51 P1 02H 0.00 TEH TEC 11 11 DSI 1.08 45 P1 01H 0.00 TEH TEC 11 11 SAI 0.30 108 6

01H 0.00 0.36 01H 01H 11 13 DSI 1.03 47 P1 03H 0.02 TEH TEC 11 14 DSI 0.63 96 P1 O1H 0.00 TEH TEC 11 14 SAI 0.20 122 6

01H 0.00 0.45 01H 01H 11 16 DSI 0.80 116 P1 01H

-0.05 TEH TEC 11 16 DSI 0.57 47 P1 02H

-0.02 TEH TEC 11 18 DSI 0.59 55 P1 01H 0.05 TEH TEC 11 21 DSI 1.18 82 P1 01H

-0.02 TEH TEC 11 21 DSI 0.96 53 P1 02H 0.02 TEH TEC 11 22 NQI 0.41 122 3

TSC 15.27 2SH TEC 11 23 DSI 0.62 96 P1 01H

-0.05 TEH TEC 11 23 MAI 0.34 83 6

01H 0.13 0.25 01H 01H 11 24 DSI 1.18 28 P1 01H 0.07 TEH TEC 11 24 MAI 0.36 93 6

01H -0.02 0.23 01H 01H 11 26 DSI 1.02 84 P1 02H

-0.19 1SH TEC 11 26 DSI 0.37 67 P1 05H 0.11 1SH TEC 11 28 DSI 0.46 36 P1 02H 0.05 1SH TEC 11 33 NOI 0.28 108 3

01C 25.34 1SH TEC 11 33 NQI 0.38 83 3

02C 20.38 1SH TEC 11 33 NQI 0.49 145 3

02C 40.13 1SH TEC 11 33 DSI 0.49 79 P1 02H

-0.03 1SH TEC 11 39 DSI 0.63 70 P1 01H

-0.05 STH TEC 11 39 NQI 0.38 113 3

02C 32.45 STH TEC 11 40 DSI 0.80 64 P1 01H 0.00 STH TEC 11 40 NQI 0.42 111 3

02C 29.15 STH TEC 11 40 PTP 0.78 91 6

STH 1.20 STH STH 11 42 DSI 0.79 92 P1 02H

-0.08 1SH TEC 11 44 DSI 0.80 96 P1 01H

-0.11 STH TEC 11 44 DSI 0.52 119 P1 02H

-0.08 STH TEC 11 46 DSI 0.57 133 P1 02H 0.00 1SH TEC 11 46 SAI 1.23 113 2

02H

-0.03 0.55 02H 02H 11 47 DSI 1.15 105 P1 01H 0.00 STH TEC 11 47 DSI 0.73 94 P1 02H

-0.08 STH TEC 11 53 DSI 0.80 67 P1 01H -0.25 STH TEC 11 56 DSI 0.59 44 P1 02H 0.05 TEH TEC 11 57 DSI 1.19 29 P1 01H 0.07 TEH TEC 11 57 SAI 0.18 109 6

01H 0.07 0.25 01H 01H 11 59 DSI 0.99 89 P1 01H 0.07 TEH TEC 11 59 DSI 0.51 76 P1 02H 0.17 TEH TEC 11 63 DSI 0.87 85 P1 01H 0.25 TEH TEC 11 63 DSI 0.33 109 P1 02H

-0.10 TEH TEC 11 63 SAI 0.17 109 6

02H

-0.13 0.70 02H 02H 11 63 DSI 0.50 133 P1 04H

-0.17 TEH TEC 11 63 SAI 0.39 96 6

04H 0.16 0.55 04H 04H 11 66 DSI 1.06 54 P1 01H

-0.07 TEH TEC 11 67 DSI 0.49 62 P1 01H 0.07 TEH TEC 11 67 DSI 0.66 56 P1 02H 0.03 TEH TEC

Beaver Valley Unit #1 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Page 18 of 54 Row Col 11 67 11 67 11 72 11 72 11 74 11 76 11 77 11 77 11 77 11 77 11 88 11 93 12 2

12 4

12 4

12 5

12 5

12 6

12 7

12 8

12 8

12 8

12 8

12 8

12 8

12 9

12 9

12 10 12 10 12 14 12 18 12 18 12 18 12 19 12 19 12 19 12 21 12 21 12 21 12 21 12 23 12 24 12 24 12 24 12 32 12 32 12 32 12 33 12 35 12 35 12 35 Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To DSI 0.45 88 P1 03H 0.28 TEH TEC SAI 0.35 55 6

03H 0.21 0.43 03H 03H DSI 1.06 30 P1 01H 0.02 TEH TEC MAI 0.27 86

' 6 01H

-0.01 0.35 01H 01H DSI 0.83 53 P1 01H 0.00 TEH TEC DSI 0.37 50 P1 01H

-0.02 TEH TEC DSI 4.57 60 P1 01H 0.05 TEH TEC MAI 2.36 65 6

01H

-0.04 0.54 01H 01H DSI 0.50 59 P1 02H 0.00 TEH TEC SAI 0.31 94 6

02H 0.00 0.56 02H 02H DSI 0.57 62 P1 02H 0.10 TEH TEC PCT 0.54 140 0

P1 03C

-0.13 TEH TEC DSI 0.43 55 P1 01H 0.03 TEH TEC PCT 0.44 0

27 3

02C 0.21 02C 02C VOL 0.47 61 3

02C 0.20 02C 02C DSI 0.62 100 P1 01H 0.19 TEH TEC DSI 0.53 35 P1 03H 0.03 TEH TEC DSI 0.55 50 P1 01H

-0.05 TEH TEC DSI 0.55 37 P1 02H 0.03 TEH TEC DSI 0.92 104 P1 01H

-0.02 TEH TEC DSI 1.35 78 P1 02H 0.03 TEH TEC DSI 1.14 121 P1 03H 0.25 TEH TEC DSI 0.65 111 P1 04H

-0.05 TEH TEC DSI 0.62 87 P1 07H

-0.14 TEH TEC SAI 0.19 123 2

07H

-0.14 0.38 07C 07H DSI 1.34 20 P1 01H 0.00 TEH TEC SAI 0.36 99 6

01H

-0.01 0.45 01H 01H DSI 1.00 37 P1 02H 0.02 TEH TEC SAI 0.32 108 6

02H 0.00 0.45 02H 02H DSI 0.87 36 P1 01H 0.02 TEH TEC DSI 1.43 28 P1 01H

-0.07 TEH TEC SAI 0.23 109 6

01H

-0.21 0.23 01H 01H DSI 0.84 54 P1 02H

-0.07 TEH TEC DSI 0.47 105 P1 01H

-0.12 TEH TEC DSI 0.66 52 P1 02H 0.00 TEH TEC MAI 0.29 85 6

02H

-0.15 0.31 02H 02H DSI 1.03 75 P1 01H 0.00 TEH TEC MAI 0.47 100 6

01H

-0.04 0.47 01H 01H DSI 1.05 104 P1 02H

-0.20 TEH TEC DSI 0.77 91 P1 03H

-0.17 TEH TEC DSI 0.75 65 P1 01H 0.02 TEH TEC DSI 1.20 26 P1 01H 0.10 TEH TEC SAI 0.14 87 6

01H 0.01 0.29 01H 01H DSI 0.71 33 P1 02H 0.10 TEH TEC DSI 1.36 171 P1 01H 0.03 STH TEC SPR 2.37 42 P1 01H 0.00 STH TEC SAI 0.60 96 2

01H 0.17 0.36 01H 01H DSI 0.31 83 P1 01H 0.03 STH TEC DSI 1.11 120 P1 01H

-0.16 STH TEC SAI 0.62 101 2

01H

-0.19 0.29 01H 01H SAI 0.62 101 2

01H

-0.19 0.29 01H 01H

Beaver Valley Unit #1 Page 19 of 54 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 12 35 NOI 0.53 111 3

02C 22.74 STH TEC 12 35 NOI 0.78 120 3

02C 26.41 STH TEC 12 35 DSI 0.92 107 P1 02H

-0.21 STH TEC 12 35 SPR 1.58 96 P1 02H 0.00 STH TEC 12 35 SAI 0.86 100 2

02H

-0.26 0.27 02H 02H 12 35 DSI 0.87 120 P1 03H 0.29 STH TEC 12 35 SAI 0.88 110 2

03H 0.19 0.27 03H 03H 12 37 DSI 0.54 30 P1 01H 0.00 STH TEC 12 40 DSI 1.37 86 P1 01H 0.00 STH TEC 12 41 DSI 0.58 65 P1 01H 0.02 TSH TEC 12 41 DSI 0.60 58 P1 01H 0.00 TEH TEC 12 42 DSI 0.50 111 P1 01H 0.05 STH TEC 12 44 DSI 0.82 98 P1 03H

-0.13 2SH TEC 12 46 DSI 0.75 108 P1 01H

-0.21 STH TEC 12 46 SAI 1.50 106 2

01H 0.02 0.54 01H 01H 12 46 DSI 0.72 166 P1 02H

-0.03 STH TEC 12 47 DSI 0.70 98 P1 01H

-0.05 STH TEC 12 48 DSI 0.69 123 P1 01H

-0.05 STH TEC 12 49 DSI 0.84 87 P1 01H

-0.08 STH TEC 12 50 DSI 1.42 92 P1 01H

-0.07 TEH TEC 12 50 MAI 0.18 92 6

TSH 0.59 0.39 TSH TSH 12 51 DSI 0.89 85 P1 02H

-0.17 1SH TEC 12 54 DS 11.70 62 P1 01H 0.07 TEH TEC 12 54 DSI 0.37 67 P1 02H 0.08 TEH TEC 12 55 DS0 0.85 45 P1 01H 0.00 TEH TEC 12 56 DSI 0.84 56 P1 01H 0.10 TEH TEC 12 56 SAI 0.44 89 6

01H 0.10 0.35 01H 01H 12 56 DSI 0.58 75 P1 02H 0.02 TEH TEC 12 57 DSI 0.47 118 P1 01H 0.15 TEH TEC 12 57 DSI 0.40 46 P1 02H 0.00 TEH TEC 12 57 DNI 0.66 136 5

04C 16.03 TEH TEC 12 59 DSI 1.09 54 P1 01H 0.15 TEH TEC 12 59 DSI 0.46 118 P1 02H 0.12 TEH TEC 12 60 DSI 0.48 35 P1 01H 0.02 TEH TEC 12 61 DSI 0.57 107 P1 01H

-0.10 TEH TEC 12 62 DSI 1.12 55 P1 01H 0.08 TEH TEC 12 62 DSI 0.96 63 P1 02H 0.20 TEH TEC 12 64 DSI 0.74 67 P1 02H

-0.15 TEH TEC 12 64 SAI 0.31 101 6

02H

-0.11 0.65 02H 02H 12 66 DSI 0.53 70 P1 02H 0.03 TEH TEC 12 69 PTP 0.94 95 6

STH 1.20 STH STH 12 70 DSI 1.03 39 P1 02H 0.00 TEH TEC 12 70 SAI 0.43 105 6

02H 0.00 0.43 02H 02H 12 73 DSI 0.25 62 P1 01H 0.07 TEH TEC 12 76 DSI 0.72 37 P1 01H 0.00 TEH TEC 12 77 DSI 0.83 61 P1 02H

-0.02 TEH TEC 12 77 SAI 0.25 91 6

02H 0.07 0.48 02H 02H 12 78 DSI 0.65 129 P1 01H 0.10 TEH TEC 12 78 DSI 1.11 64 P1 02H 0.02 TEH TEC 12 82 DSI 0.45 92 P1 03H 0.27 TEH TEC 12 84 DSI 0.89 141 P1 01H 0.00 TEH TEC

Beaver Valley Unit #1 Page 20 of 54 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inchl Cr-Length Cr-Angle From To 12 84 DSI 0.98 47 P1 03H 0.12 TEH TEC 12 84 MAI 0.23 85 6

03H 0.03 0.35 03H 03H 12 88 DSI 0.55 45 P1 02H 0.00 TEH TEC 12 88 SAI 0.21 101 6

02H 0.16 0.24 02H 02H 12 90 DSI 0.23 85 P1 07H 0.10 TEH TEC 12 90 SAI 0.18 110 2

07H

-0.01 0.51 07C 07H 12 92 PCT 1.12 120 8

P1 01C

-0.15 TEH TEC 12 93 DSI 0.69 110 P1 02H 0.28 TEH TEC 12 93 SVI 0.19 66 6

02H 0.19 0.23 80 02H 02H 13 3

DSI 1.25 89 P1 01H 0.05 TEH TEC 13 3

MAI 0.28 98 6

01H 0.05 0.65 01H 01H 13 4

DSI 0.89 39 P1 01H 0.03 TEH TEC 13 4

DS1 0.31 54 P1 02H 0.05 TEH TEC 13 6

DSI 0.75 40 P1 01H 0.05 TEH TEC 13 7

DSI 0.63 82 P1 02H 0.00 TEH TEC 13 9

DSI 1.03 69 P1 01H 0.02 TEH TEC 13 9

DSI 0.56 52 P1 05H 0.08 TEH TEC 13 10 DSI 0.95 29 P1 01H 0.07 TEH TEC 13 10 MAI 0.37 96 6

01H 0.00 0.59 01H 01H 13 10 DSI 0.31 126 P1 02H 0.00 TEH TEC 13 11 DSI 0.42 44 P1 01H

-0.02 TEH TEC 13 11 DSI 0.41 98 P1 02H

-0.07 TEH TEC 13 12 DSI 0.60 63 P1 01H 0.02 TEH TEC 13 12 DSI 1.03 51 P1 02H

-0.02 TEH TEC 13 13 DSI 0.49 54 P1 02H 0.05 TEH TEC 13 15 DSI 0.68 85 P1 01H

-0.07 TEH TEC 13 15 DSI 0.66 30 P1 02H

-0.05 TEH TEC 13 17 DSI 0.84 46 P1 01H 0.05 TEH TEC 13 19 DSI 0.81 95 P1 01H

-0.02 TEH TEC 13 19 DSI 0.39 49 P1 02H 0.07 TEH TEC 13 21 DSI 0.51 49 P1 01H 0.00 TEH TEC 13 21 DSI 1.06 47 P1 02H 0.07 TEH TEC 13 21 SAI 0.26 103 6

02H 0.00 0.23 02H 02H 13 21 DSI 0.72 110 P1 03H 0.25 TEH TEC 13 21 SAI 0.21 116 6

03H 0.00 0.44 03H 03H 13 22 DSI 1.06 91 P1 01H 0.07 TEH TEC 13 22 DSI 0.15 107 P1 02H 0.07 TEH TEC 13 26 DSI 0.68 83 P1 01H

-0.13 STH TEC 13 26 DSI 0.16 25 P1 02H 0.05 STH TEC 13 27 DS0 1.60 32 P1 01H

-0.03 TEH TEC 13 27 DSI 0.63 62 P1 03H

-0.18 TEH TEC 13 27 SAI 0.13 99 6

03H 0.00 0.36 03H 03H 13 30 DSI 0.94 65 P1 01H 0.00 STH TEC 13 32 DSI 1.25 68 P1 01H 0.00 STH TEC 13 35 DSI 0.40 114 P1 01H

-0.19 STH TEC 13 35 SAI 0.43 96 2

01H 0.11 0.33 01H 01H 13 36 DSI 0.91 96 P1 01H

-0.03 STH TEC 13 37 DSI 0.90 32 P1 01H 0.00 STH TEC 13 37 PTP 0.77 76 6

STH 1.55 STH STH 13 38 DSI 1.03 74 P1 01H 0.00 STH TEC 13 41 PTP 0.65 75 6

STH 1.17 STH STH

Beaver Valley Unit #1 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Page 21 of 54 Row Col 13 43 13 47 13 47 13 47 13 47 13 47 13 47 13 49 13 55 13 56 13 58 13 62 13 62 13 63 13 64 13 66 13 67 13 68 13 68 13 70 13 70 13 72 13 72 13 78 13 85 13 92 14 3

14 3

14 6

14 6

14 6

14 6

14 6

14 6

14 7

14 8

14 9

14 12 14 13 14 15 14 15 14 18 14 18 14 19 14 20 14 21 14 21 14 22 14 26 14 29 14 31 Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To DSI 0.99 80 P1 O1H

-0.03 STH TEC DSI 1.47 118 P1 O1H 0.16 STH TEC DSI 1.13 138 P1 02H 0.24 STH TEC SAI 0.33 113 2

02H 0.20 0.24 02H 02H DSI 1.39 12 P1 04H 0.05 STH TEC SPR 2.44 164 P1 04H 0.00 STH TEC SAI 0.24 58 2

04H

-0.08 0.24 04H 04H DSI 0.66 117 P1 O1H 0.05 STH TEC DSI 0.70 103 P1 O1H 0.12 TEH TEC DSI 0.81 58 P1 01H 0.02 TEH TEC DSI 0.56 58 P1 01H 0.15 TEH TEC DSI 1.61 46 P1 01H 0.00 TEH TEC MAI 0.28 99 6

01H

-0.10 0.50 01H 01H DSI 0.58 70 P1 01H

-0.02 TEH TEC DSI 0.69 34 P1 01H 0.00 TEH TEC DSI 0.76 25 P1 O1H 0.00 TEH TEC DSI 0.73 61 P1 01H 0.02 TEH TEC DSI 0.54 62 P1 01H

-0.10 TEH TEC SAI 0.58 98 6

01H

-0.10 0.36 01H 01H DSI 0.74 114 P1 03H

-0.12 TEH TEC SAI 0.30 87 6

03H

-0.13 0.41 03H 03H DSI 0.86 32 P1 01H 0.02 TEH TEC DSI 0.59 28 P1 02H 0.10 TEH TEC DSI 0.68 74 P1 02H

-0.10 TEH TEC DSI 0.77 60 P1 02H 0.05 TEH TEC PCT 0.59 134 0

P1 01C -0.20 TEH TEC PCT 0.69 121 9

P1 01C

-0.05 TEH TEC PCT 0.45 126 0

P1 02C -0.08 TEH TEC DSI 1.96 96 P1 01H 0.02 TEH TEC MAI 0.76 97 6

01H 0.00 0.43 01H 01H DSI 0.89 68 P1 03H 0.03 TEH TEC MAI 0.43 97 6

03H 0.00 0.47 03H 03H DSI 0.51 57 P1 07H 0.00 TEH TEC SAI 0.14 106 2

07H

-0.02 0.28 07C 07H DSI 0.46 152 P1 01H 0.13 TEH TEC DSI 0.73 44 P1 01H 0.00 TEH TEC DSI 1.03 61 P1 O1H 0.00 TEH TEC DSI 0.83 72 P1 O1H

-0.02 TEH TEC DSI 0.93 90 P1 O1H

-0.12 TEH TEC DSI 0.97 43 P1 O1H

-0.12 TEH TEC SAI 0.38 94 6

O1H 0.00 0.43 O1H O1H DSI 0.68 54 P1 O1H 0.05 TEH TEC DSI 0.58 26 P1 02H 0.05 TEH TEC DSI 0.45 52 P1 02H 0.02 TEH TEC DSI 0.58 33 P1 O1H 0.10 TEH TEC DSI 1.19 65 P1 01H 0.05 TEH TEC DSI 0.39 71 P1 02H 0.00 TEH TEC DSI 0.71 37 P1 02H

-0.05 TEH TEC SAI 0.14 79 6

TSH 0.10 0.39 TSH TSH DSI 0.56 59 P1 01H 0.05 STH TEC DS0 0.69 74 P1 01H

-0.05 STH TEC

Beaver Valley Unit #1 Page 22 of 54 1 R15 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 14 34 DSI 1.49 57 P1 03H

-0.08 2SH TEC 14 37 DSI 1.17 79 P1 02H

-0.16 1SH TEC 14 38 NOI 0.53 116 3

02C 27.87 1SH TEC 14 38 DSI 1.18 102 P1 02H

-0.13 1SH TEC 14 39 NQI 0.59 102 3

03C 40.63 2SH TEC 14 39 NOI 0.37 112 3

03C 26.74 2SH TEC 14 39 DSI 0.81 106 P1 03H

-0.16 2SH TEC 14 39 SAI 0.55 112 2

03H

-0.16 0.24 03H 03H 14 40 DSI 0.94 86 P1 01H 0.21 STH TEC 14 45 NOI 0.65 108 3

06C 15.65 STH TEC 14 46 DSI 1.53 80 P1 01H

-0.05 STH TEC 14 46 SPR 2.24 77 P1 01H 0.00 STH TEC 14 46 MAI 1.14 98 2

01H

-0.02 0.72 01H 01H 14 46 DSI 0.68 116 P1 04H

-0.16 STH TEC 14 47 DSI 0.88 100 P1 01H 0.00 STH TEC 14 47 DSI 1.00 125 P1 02H -0.13 STH TEC 14 48 DSI 1.16 100 P1 01H

-0.08 STH TEC 14 48 SPR 1.87 99 P1 01H 0.00 STH TEC 14 48 MAI 1.24 90 2

01H 0.01 0.42 01H 01H 14 49 DSI 0.85 79 P1 01H 0.03 STH TEC 14 50 DSI 0.87 43 P1 02H 0.05 STH TEC 14 51 DSI 0.23 95 P1 01H 0.08 STH TEC 14 52 DSI 0.96 111 P1 01H

-0.08 STH TEC 14 52 NOI 0.59 111 3

04C 36.85 STH TEC 14 53 NOI 0.62 124 3

06C 15.65 1SH TEC 14 56 DSI 1.83 66 P1 01H 0.00 TEH TEC 14 58 DSI 0.61 110 P1 01H

-0.17 TEH TEC 14 58 SAI 0.25 101 6

01H

-0.03 0.52 01H 01H 14 59 DSI 1.67 75 P1 01H

-0.12 TEH TEC 14 59 DSI 1.22 66 P1 02H 0.12 TEH TEC 14 63 DSI 0.76 66 P1 01H

-0.05 TEH TEC 14 63 DSI 1.02 115 P1 02H 0.05 TEH TEC 14 64 DSI 0.57 78 P1 01H

-0.05 TEH TEC 14 67 DSI 0.98 51 P1 01H 0.02 TEH TEC 14 67 DS]

0.56 123 P1 02H

-0.05 TEH TEC 14 68 DSI 1.01 26 P1 01H

-0.05 TEH TEC 14 69 DSI 0.59 29 P1 01H 0.02 TEH TEC 14 72 PTP 0.93 56 6

STH 1.76 STH STH 14 73 DSI 0.58 41 P1 02H 0.05 TEH TEC 14 74 DSI 1.43 90 P1 01H 0.12 TEH TEC 14 75 DSI 0.60 40 P1 02H 0.10 TEH TEC 14 79 DSI 0.60 28 P1 01H 0.10 TEH TEC 14 84 DSI 0.77 65 P1 03H 0.02 TEH TEC 14 87 DSI 0.96 79 P1 02H 0.08 TEH TEC 14 92 VOL 0.66 54 3

01C 0.00 01C 01C 14 92 PCT 0.55 0

30 3

01C

-0.06 01C 01C 15 3

DSI 1.21 53 P1 01H 0.03 TEH TEC 15 6

DSI 0.32 65 P1 01H 0.03 TEH TEC 15 8

DSI 0.61 84 P1 01H 0.00 TEH TEC 15 9

DSI 0.74 125 P1 01H

-0.20 TEH TEC 15 9

DSI 0.73 81 P1 02H

-0.10 TEH TEC

Beaver Valley Unit #1 Page 23 of 54 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inchl Cr-Length Cr-Angle From To 15 13 DSI 0.71 45 P1 011H 0.00 TEH TEC 15 22 DSI 0.40 22 P1 02H 0.12 TEH TEC 15 22 SAI 0.30 109 6

02H 0.08 0.25 02H 02H 15 23 SPR 1.63 95 P1 02H 0.00 1SH TEC 15 23 SAI 1.06 100 2

02H 0.11 0.52 02H 02H 15 24 DSI 0.89 115 P1 01H 0.08 STH TEC 15 26 DSI 0.68 36 P1 01H 0.10 TEH TEC 15 27 DSI 0.55 23 P1 01H 0.05 TEH TEC 15 28 DSI 1.85 46 P1 01H 0.00 TEH TEC 15 28 SAI 1.06 78 6

011H 0.00 0.43 01H 01H 15 29 DSI 1.15 47 P1 01H 0.00 STH TEC 15 30 DSI 1.25 91 P1 01H 0.13 STH TEC 15 35 DSI 1.04 154 P1 02H 0.29 1SH TEC 15 35 SPR 2.08 125 P1 02H 0.00 1SH TEC 15 35 MAI 0.69 104 2

02H 0.08 0.65 02H 02H 15 37 NQI 0.64 119 3

03C 43.78 STH TEC 15 37 NQI 0.44 113 3

03C 45.53 STH TEC 15 37 NQI 0.42 86 3

04C 7.73 STH TEC 15 37 NOI 0.72 110 3

06C 44.14 STH TEC 15 40 SAI 0.46 75 6

TSH 0.66 0.36 TSH TSH 15 41 PTP 0.33 82 6

STH 1.16 STH STH 15 42 DSI 1.24 69 P1 02H 0.13 STH TEC 15 42 SPR 1.84 81 P1 02H 0.00 STH TEC 15 42 SAI 1.43 110 2

02H 0.00 0.58 02H 02H 15 42 DSI 1.21 78 P1 03H

-0.05 STH TEC 15 42 PTP 0.83 77 6

STH 1.17 STH STH 15 43 DSI 0.84 71 P1 01H 0.05 STH TEC 15 46 DSI 0.67 55 P1 01H 0.05 STH TEC 15 52 DSI 0.68 84 P1 01H 0.27 TEH TEC 15 53 DSI 0.82 92 P1 01H

-0.05 TEH TEC 15 53 SAI 0.29 94 6

01H

-0.17 0.52 01H 01H 15 54 DSI 0.41 40 P1 01H 0.00 TEH TEC 15 58 DSI 0.50 63 P1 011H 0.10 TEH TEC 15 59 DSI 1.66 61 P1 01H 0.00 TEH TEC 15 60 DSI 0.90 60 P1 01H 0.07 TEH TEC 15 61 DSI 1.36 25 P1 01H 0.10 TEH TEC 15 61 MAI 0.17 66 6

01H

-0.03 0.31 01H 01H 15 62 DSI 0.90 57 P1 01H 0.10 TEH TEC 15 64 DSI 1.12 89 P1 01H 0.15 TEH TEC 15 65 DSI 0.90 79 P1 01H 0.07 TEH TEC 15 66 DSI 0.69 102 P1 01H 0.10 TEH TEC 15 66 DSI 0.48 155 P1 02H 0.20 TEH TEC 15 67 DSI 0.48 18 P1 01H 0.02 TEH TEC 15 68 DSI 0.34 116 P1 02H 0.07 TEH TEC 15 70 DSI 0.54 90 P1 011H

-0.03 TEC TEH 15 70 DSI 0.74 61 P1 02H

-0.06 TEC TEH 15 72 DSI 0.42 22 P1 01H 0.10 TEH TEC 15 73 DSI 1.03 31 P1 01H 0.02 TEH TEC 15 73 SAI 0.43 98 6

01H 0.02 0.29 01H 01H 15 74 DSI 1.29 53 P1 01H 0.03 TEH TEC 15 74 DSI 1.37 82 P1 02H 0.25 TEH TEC

Beaver Valley Unit #1 Page 24 of 54 1 R15 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Cot Ind Volts Phase %TW Chan Loc Inchl Cr-Length Cr-Angle From To 15 74 SAI 0.27 76 6

02H 0.25 0.11 02H 02H 15 78 DSI 0.79 100 P1 01H 0.05 TEH TEC 15 78 DSI 0.83 40 P1 02H 0.07 TEH TEC 15 78 SAI 0.34 81 6

02H 0.05 0.41 02H 02H 15 78 WAR 0.31 106 2

AV1

-0.01 07C 07H 15 78 WAR 0.35 115 2

AV2

-0.01 07C 07H 15 78 WAR 0.33 116 2

AV3

-0.01 07C 07H 15 78 WAR 0.34 116 2

AV4 0.00 07C 07H 15 81 DSI 0.79 55 P1 01H 0.05 TEH TEC 15 81 DSI 1.14 51 P1 02H 0.05 TEH TEC 15 90 PCT 0.75 127 0

P1 01C

-0.12 TEH TEC 15 92 PCT 0.35 130 0

P1 02C

-0.15 TEH TEC 16 4

PCT 1.12 132 0

P1 01C 0.05 TEH TEC 16 5

PCT 0.69 139 0

P1 01C

-0.13 06C TEC 16 5

PCT 0.73 144 0

P1 01C

-0.15 TEH TEC 16 5

DSI 1.01 89 P1 01H 0.02 TEH TEC 16 10 DSI 0.99 59 P1 01H 0.02 TEH TEC 16 11 DSI 0.73 51 P1 02H

-0.05 TEH TEC 16 12 DSI 1.52 78 P1 01H 0.00 TEH TEC 16 12 SAI 0.94 80 6

01H 0.00 0.74 01H 01H 16 12 DSI 1.08 87 P1 02H 0.05 TEH TEC 16 12 DSI 1.49 96 P1 03H

-0.12 TEH TEC 16 13 DSI 0.76 89 P1 01H 0.00 TEH TEC 16 13 DSI 1.52 112 P1 02H 0.22 TEH TEC 16 13 DSI 1.32 64 P1 03H

-0.07 TEH TEC 16 13 DSI 0.78 99 P1 04H

-0.18 TEH TEC 16 14 DSI 0.35 39 P1 01H 0.05 TEH TEC 16 14 CSI 0.15 76 5

07H 0.19 49 07C 07H 16 16 DSI 0.82 36 P1 01H 0.05 TEH TEC 16 17 DSI 0.30 129 P1 01H 0.10 TEH TEC 16 18 DSI 0.76 52 P1 01H

-0.02 TEH TEC 16 20 DSI 0.55 42 P1 01H 0.07 TEH TEC 16 20 MAI 0.40 109 6

01H 0.00 0.55 01H 01H 16 21 DSI 0.82 53 P1 01H 0.07 TEH TEC 16 22 DSI 0.89 75 P1 01H 0.00 TEH TEC 16 22 MAI 0.53 86 6

01H 0.07 0.29 01H 01H 16 22 DSI 0.75 58 P1 02H

-0.02 TEH TEC 16 23 DSI 1.47 93 P1 01H

-0.12 TEH TEC 16 23 SPR 1.94 126 P1 01H 0.00 TEH TEC 16 23 MAI 0.49 82 6

01H

-0.13 0.23 01H 01H 16 25 DSI 1.59 41 P1 01H 0.10 TEH TEC 16 25 MAI 0.30 120 6

01H

-0.10 0.29 01H 01H 16 25 DSI 1.21 69 P1 03H

-0.05 TEH TEC 16 27 DSI 0.55 34 P1 01H 0.02 TEH TEC 16 28 DSI 0.56 51 P1 01H 0.03 TEH TEC 16 28 SAI 0.18 105 6

TSH 0.16 0.23 TSH TSH 16 29 DSI 0.78 43 P1 01H

-0.05 STH TEC 16 33 DSI 0.61 38 P1 01H 0.03 STH TEC 16 35 DSI 0.88 75 P1 01H 0.00 STH TEC 16 35 DSI 0.81 115 P1 02H

-0.16 STH TEC 16 36 DSI 1.04 109 P1 01H

-0.05 STH TEC

Beaver Valley Unit #1 Page 25 of 54 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 16 37 DSI 1.23 109 P1 011H 0.18 STH TEC 16 37 DSI 0.74 65 P1 02H 0.11 STH TEC 16 39 DSI 0.81 45 P1 01H 0.05 STH TEC 16 41 PTP 0.50 54 6

STH 1.16 STH STH 16 42 DSI 0.64 107 P1 03H

-0.16 2SH TEC 16 42 SAI 0.47 110 2

03H

-0.14 0.33 03H 03H 16 44 DSI 1.02 71 P1 01H 0.11 STH TEC 16 46 DSI 0.70 101 P1 01H

-0.11 STH TEC 16 49 DSI 0.69 78 P1 01H 0.02 TEH TEC 16 49 DSI 0.67 89 P1 02H 0.20 TEH TEC 16 54 DSI 0.32 58 P1 01H 0.00 TEH TEC 16 56 DSI 0.98 33 P1 01H 0.05 TEH TEC 16 56 DSI 1.10 35 P1 02H 0.12 TEH TEC 16 56 SPR 1.63 49 P1 02H 0.00 TEH TEC 16 56 SAI 0.15 88 6

02H 0.00 0.16 02H 02H 16 57 DSI 0.90 33 P1 01H 0.05 TEH TEC 16 58 DSI 1.24 85 P1 01H 0.12 TEH TEC 16 59 DSI 1.58 75 P1 01H 0.05 TEH TEC 16 59 MAI 0.43 100 6

01H

-0.02 0.43 01H 01H 16 59 DSI 1.22 79 P1 02H 0.00 TEH TEC 16 61 DSI 0.59 99 P1 02H

-0.15 TEH TEC 16 61 DSI 0.66 33 P1 03H 0.00 TEH TEC 16 62 DSI 0.34 113 P1 01H 0.07 TEH TEC 16 63 DSI 0.73 99 P1 01H 0.12 TEH TEC 16 63 DSI 0.65 47 P1 02H 0.10 TEH TEC 16 64 DSI 1.65 91 P1 01H 0.12 TEH TEC 16 64 MAI -

0.98 84 6

01H 0.12 0.50 01H 01H 16 67 DSI 1.24 92 P1 01H 0.15 TEH TEC 16 67 DSI 0.66 62 P1 02H

-0.02 TEH TEC 16 67 DSI 0.64 30 P1 05H 0.10 TEH TEC 16 70 DSI 0.61 30 P1 01H 0.02 TEH TEC 16 73 DSI 0.58 44 P1 01H 0.12 TEH TEC 16 83 DNI 0.80 52 5

06C 37.60 TEH TEC 16 85 DSI 0.83 56 P1 02H 0.13 TEH TEC 16 85 DSI 1.10 96 P1 03H 0.00 TEH TEC 16 85 SAI 1.05 90 6

03H 0.00 0.38 03H 03H 16 86 DSI 1.30 74 P1 02H 0.02 TEH TEC 16 86 DSI 0.48 74 P1 03H 0.05 TEH TEC 17 5

PCT 2.24 105 38 P1 01C

-0.15 TEH TEC 17 5

PCT 0.71 131 0

P1 02C 0.08 TEH TEC 17 7

DSI 0.53 48 P1 03H

-0.03 TEH TEC 17 11 DSI 0.37 34 P1 03H 0.08 TEH TEC 17 12 DSI 0.49 85 P1 01H

-0.02 TEH TEC 17 13 DSI 0.62 44 P1 01H 0.00 TEH TEC 17 13 DSI 1.35 54 P1 02H 0.02 TEH TEC 17 14 DSI 0.91 47 P1 01H 0.07 TEH TEC 17 16 DSI 0.75 66 P1 01H 0.07 TEH TEC 17 16 DSI 0.86 95 P1 02H

-0.20 TEH TEC 17 19 DSI 0.92 161 P1 01H 0.05 TEH TEC 17 19 SAI 0.29 111 6

01H 0.00 0.41 01H 01H 17 19 DSI 2.03 18 P1 02H

-0.16 TEH TEC

Beaver Valley Unit #1 Page 26 of 54 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 17 19 SAI 0.47 98 6

02H 0.01 0.43 02H 02H 17 21 DSI 0.44 117 P1 01H 0.15 TEH TEC 17 23 DSI 0.60 77 P1 02H 0.02 TEH TEC 17 23 SAI 0.49 101 6

02H 0.00 0.38 02H 02H 17 24 DSI 0.91 58 P1 01H 0.00 TEH TEC 17 24 SAI 0.29 105 6

011H 0.00 0.27 01H 01H 17 24 DSI 0.40 60 P1 02H

-0.02 TEH TEC 17 26 DSI 0.54 47 P1 01H 0.05 TEH TEC 17 31 DSI 1.58 35 P1 011H

-0.16 STH TEC 17 31 SPR 2.57 28 P1 01H 0.00 STH TEC 17 31 SAI 0.65 101 2

01H

-0.06 0.54 011H 01H 17 33 DSI 0.69 55 P1 01H 0.03 STH TEC 17 34 DSI 0.31 82 P1 01H 0.03 STH TEC 17 34 SAI 1.00 100 2

O1H

-0.04 0.49 01H 01H 17 35 DSI 0.37 131 P1 O1H 0.11 STH TEC 17 36 DSI 0.36 148 P1 02H 0.08 STH TEC 17 37 DSI 0.76 87 P1 01H

-0.05 STH TEC 17 37 DSI 1.05 110 P1 02H

-0.18 STH TEC 17 40 DSI 1.10 125 P1 02H

-0.16 STH TEC 17 41 DSI 0.89 101 P1 01H

-0.11 STH TEC 17 42 DSI 0.48 92 P1 01H

-0.11 STH TEC 17 43 DSI 1.40 74 P1 01H 0.03 STH TEC 17 44 DSI 0.96 72 P1 01H 0.02 TEH TEC 17 44 DSI 0.35 34 P1 04H 0.03 TEH TEC 17 46 DSI 0.55 96 P1 01H 0.03 STH TEC 17 54 DSI 0.73 46 P1 01H 0.00 TEH TEC 17 55 DSI 0.81 97 P1 01H

-0.12 TEH TEC 17 55 DS0 0.71 78 P1 02H 0.25 TEH TEC 17 56 DSI 0.99 73 P1 01H

-0.10 TEH TEC 17 56 SAI 0.79 15 6

TSH

-0.18 0.20 TSH TSH 17 59 NQI 0.72 113 3

03C 28.17 2SH TEC 17 59 DSI 1.35 107 P1 03H

-0.19 2SH TEC 17 59 NQI 1.13 108 3

05C 28.48 2SH TEC 17 59 DSI 0.23 28 P1 07H 0.00 2SH TEC 17 59 SAI 0.25 121 2

07H 0.10 0.45 07C 07H 17 59 WAR 0.32 107 2

AV1 1.49 07C 07H 17 59 WAR 0.46 130 2

AVI

-1.25 07C 07H 17 59 WAR 0.26 107 2

AV2

-0.68 07C 07H 17 59 WAR 0.66 108 2

AV2 0.57 07C 07H 17 59 WAR 0.57 110 2

AV3 1.78 07C 07H 17 59 WAR 0.89 110 2

AV3

-1.96 07C 07H 17 60 DSI 1.21 68 P1 01H 0.02 TEH TEC 17 60 DSI 0.36 93 P1 02H 0.00 TEH TEC 17 64 DSI 0.80 82 P1 01H 0.05 TEH TEC 17 64 DSI 0.95 69 P1 02H 0.07 TEH TEC 17 66 DSI 0.84 73 P1 01H 0.20 TEH TEC 17 66 DSI 0.82 85 P1 02H 0.07 TEH TEC 17 66 SAI 0.44 89 6

02H 0.20 0.45 02H 02H 17 68 DSI 0.69 74 P1 02H 0.05 TEH TEC 17 77 DSI 0.92 42 P1 02H 0.05 TEH TEC 17 77 MAI 0.42 95 6

02H

-0.11 0.26 02H 02H

Beaver Valley Unit #1 Page 27 of 54 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 17 78 DSI 0.70 56 P1 02H 0.05 TEH TEC 17 78 SAI 0.17 104 6

02H 0.00 0.37 02H 02H 17 82 DSI 0.63 135 P1 02H

-0.10 TEH TEC 17 82 SAI 0.30 100 6

02H 0.08 0.58 02H 02H 17 83 DSI 0.60 32 P1 01H 0.07 TEH TEC 17 84 DSI 0.51 104 P1 01H 0.20 TEH TEC 17 90 PCT 0.47 0

28 3

01C 0.15 01C 01C 17 90 VOL 0.47 82 3

01C 0.09 01C 01C 18 14 DSI 0.65 44 P1 02H

-0.10 TEH TEC 18 16 DSI 0.39 63 P1 01H

-0.02 TEH TEC 18 18 DSI 0.55 36 P1 01H 0.05 TEH TEC 18 18 DSI 0.88 85 P1 02H

-0.07 TEH TEC 18 18 SAI 0.52 105 6

02H

-0.07 0.31 02H 02H 18 19 DSI 0.93 165 P1 01H 0.02 TEH TEC 18 19 SAI 0.18 95 6

01H 0.00 0.30 01H 01H 18 19 DSI 1.34 8

P1 02H 0.05 TEH TEC 18 19 SAI 0.45 109 6

02H 0.00 0.39 02H 02H 18 19 SAI 0.53 103 6

02H 0.08 0.46 02H 02H 18 19 DSI 1.62 9

P1 03H 0.07 TEH TEC 18 19 SPR 2.77 157 P1 03H 0.00 TEH TEC 18 19 SAI 0.21 107 6

03H 0.01 0.43 03H 03H 18 20 DSI 0.55 114 P1 01H 0.05 TEH TEC 18 20 SAI 0.53 108 6

01H 0.05 0.29 01H 01H 18 21 DSI 1.46 40 P1 01H 0.07 TEH TEC 18 21 MAI 0.62 97 6

01H 0.08 0.43 01H 01H 18 21 DSI 0.84 75 P1 02H

-0.20 TEH TEC 18 24 DSI 0.51 34 P1 O1H 0.02 TEH TEC 18 25 DSI 0.56 78 P1 01H

-0.02 TEH TEC 18 30 DSI 0.60 49 P1 01H 0.00 STH TEC 18 30 DSI 1.04 35 P1 02H 0.11 STH TEC 18 30 DS 11.10 61 P1 03H

-0.05 STH TEC 18 30 SPR 1.71 102 P1 03H 0.00 STH TEC 18 30 SAI 0.58 118 2

03H

-0.18 0.37 03H 03H 18 33 DSI 0.37 70 P1 01H

-0.03 STH TEC 18 36 DSI 1.17 54 P1 01H 0.03 STH TEC 18 36 SPR 1.54 87 P1 01H 0.00 STH TEC 18 36 SAI 1.78 103 2

O1H

-0.04 0.49 01H 01H 18 39 DSI 0.40 134 P1 02H 0.08 1SH TEC 18 42 DSI 0.95 37 P1 01H 0.08 STH TEC 18 43 SAI 0.18 111 6

TSH 0.28 0.30 TSH TSH 18 51 DSI 0.79 68 P1 01H 0.02 TEH TEC 18 53 NOI 0.62 108 3

03C 34.99 TEH TEC 18 53 NOI 0.46 104 3

04C 7.07 TEH TEC 18 56 DSI 1.04 95 P1 01H

-0.07 TEH TEC 18 56 NOI 0.63 114 3

TSC 24.01 TEH TEC 18 57 DSI 0.68 66 P1 01H 0.00 TEH TEC 18 59 DSI 0.76 51 P1 01H 0.02 TEH TEC 18 59 DSI 0.49 84 P1 02H

-0.20 TEH TEC 18 59 SAI 0.17 88 6

02H 0.05 0.26 02H 02H 18 61 DSI 0.76 27 P1 01H 0.05 TEH TEC 18 64 DSI 0.98 28 P1 01H 0.02 TEH TEC

Beaver Valley Unit #1 Page 28 of 54 1 R15 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 18 64 DSI 0.46 12 P1 06H 0.05 TEH TEC 18 65 DSI 0.56 121 P1 01H 0.25 TEH TEC 18 65 SAI 0.32 111 6

01H 0.07 0.55 01H 01H 18 69 DSI 0.34 133 P1 01H

-0.05 TEH TEC 18 69 DSI 0.57 97 P1 02H

-0.12 TEH TEC 18 69 SAI 0.41 97 6

02H

-0.12 0.43 02H 02H 18 75 DSI 0.72 89 P1 011H 0.07 TEH TEC 18 75 DSI 0.66 41 P1 02H 0.20 TEH TEC 18 75 SAI 0.33 101 6

02H 0.00 0.24 02H 02H 18 77 DSI 1.62 97 P1 02H 0.00 TEH TEC 18 78 DSI 1.17 36 P1 01H 0.02 TEH TEC 18 78 DNT 3.03 187 P1 01H 0.30 TEH TEC 18 78 MAI 0.70 98 6

01H

-0.10 0.35 01H 01H 18 78 DSI 1.50 22 P1 02H 0.10 TEH TEC 18 78 SPR 1.99 22 P1 02H 0.00 TEH TEC 18 78 MAI 0.50 86 6

02H

-0.08 0.32 02H 02H 18 80 DSI 0.94 54 P1 02H 0.05 TEH TEC 18 80 SAI 0.14 84 6

02H 0.00 0.22 02H 02H 18 89 PCT 1.18 128 2

P1 01C

-0.18 TEH TEC 18 89 VOL 0.30 126 3

01C

-0.17 01C 01C 19 6

PCT 1.34 122 13 P1 01C

-0.21 TEH TEC 19 6

PCT 0.61 117 24 P1 02C 0.17 TEH TEC 19 6

DSI 0.79 73 P1 04H 0.15 TEH TEC 19 9

DSI 0.43 97 P1 01H

-0.22 TEH TEC 19 9

DSI 0.48 115 P1 02H

-0.02 TEH TEC 19 9

DSI 0.75 105 P1 03H 0.10 TEH TEC 19 11 DSI 0.54 31 P1 01H 0.07 TEH TEC 19 11 DSI 0.60 30 P1 01H 0.05 TEH TEC 19 16 DSI 0.55 62 P1 02H

-0.05 TEH TEC 19 22 DSI 0.69 65 P1 011H 0.05 TEH TEC 19 25 DSI 1.08 112 P1 01H

-0.02 TEH TEC 19 25 DSI 0.62 109 P1 02H 0.00 TEH TEC 19 26 DSI 0.60 96 P1 01H 0.12 TEH TEC 19 26 SAI 0.43 69 6

TSH 0.07 0.31 TSH TSH 19 27 DSI 0.79 81 P1 01H 0.00 TEH TEC 19 30 DSI 0.50 120 P1 02H

-0.05 1SH TEC 19 31 DSI 0.46 106 P1 01H 0.12 TEH TEC 19 33 DSI 0.31 26 P1 01H 0.05 TEH TEC 19 34 DSI 0.59 69 P1 01H 0.17 TEH TEC 19 34 DSI 0.74 131 P1 02H

-0.15 TEH TEC 19 34 SAI 0.30 111 6

02H

-0.14 0.71 02H 02H 19 34 DSI 0.75 148 P1 03H

-0.13 TEH TEC 19 34 SAI 0.20 121 6

03H

-0.10 0.45 03H 03H 19 35 NQI 0.65 118 3

03C 28.03 2SH TEC 19 35 DSI 1.31 157 P1 03H 0.29 2SH TEC 19 35 SPR 2.18 127 P1 03H 0.00 2SH TEC 19 35 MAI 0.70 98 2

03H 0.18 0.68 03H 03H 19 37 NQI 0.88 121 3

04C 15.49 1SH TEC 19 37 NOI 0.88 132 3

TSC 34.47 1SH TEC 19 37 PTP 0.89 57 6

STH 0.55 STH STH 19 38 DSI 1.56 94 P1 01H 0.00 TEH TEC

Beaver Valley Unit #1 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Page 29 of 54 Row Col 19 40 19 40 19 40 19 45 19 45 19 46 19 51 19 51 19 53 19 53 19 54 19 58 19 59 19 60 19 63 19 67 19 71 19 73 19 80 19 80 19 81 19 81 19 81 19 82 19 88 19 89 20 8

20 8

20 8

20 8

20 8

20 9

20 9

20 11 20 11 20 11 20 12 20 12 20 12 20 12 20 12 20 13 20 14 20 15 20 16 20 19 20 19 20 19 20 19 20 19 20 20 Ind Volts Phase %TW Chan Loc Inchl Cr-Length Cr-Angle From To DSI 0.75 28 P1 01H 0.10 TEH TEC DSI 0.52 132 P1 02H 0.15 TEH TEC SAI 0.20 117 6

02H 0.07 0.34 02H 02H DSI 0.74 111 P1 01H 0.10 TEH TEC DSI 0.35 124 P1 01H 0.10 TEH TEC DSI 0.74 98 P1 01H

-0.18 TEH TEC DSI 0.85 95 P1 01H

-0.17 TEH TEC DSI 0.72 66 P1 02H 0.07 TEH TEC DSI 0.68 28 P1 01H 0.03 TEH TEC DSI 0.36 96 P1 02H

-0.03 TEH TEC DSI 0.85 111 P1 01H

-0.15 TEH TEC DSI 1.88 83 P1 01H

-0.06 STH TEC DSI 0.19 50 P1 02H 0.05 TEH TEC DSI 0.78 46 P1 01H 0.07 TEH TEC DSI 1.29 87 P1 02H 0.25 1SH TEC DSI 0.83 49 P1 02H

-0.03 TEH TEC DSI 1.13 60 P1 02H 0.00 TEH TEC DSI 0.47 66 P1 01H 0.02 TEH TEC DSI 1.08 41 P1 02H 0.05 TEH TEC SAI 0.49 83 6

02H 0.05 0.38 02H 02H DSI 1.23 36 P1 01H 0.02 TEH TEC SAI 0.41 104 6

01H 0.02 0.34 01H 01H DSI 0.86 38 P1 02H 0.10 TEH TEC DSI 0.64 40 P1 02H 0.08 TEH TEC PCT 0.41 123 1

P1 03C -0.17 TEH TEC PCT 0.28 134 0

P1 01C

-0.25 TEH TEC DSI 0.51 122 P1 01H 0.00 TEH TEC PCT 0.96 148 0

P1 02C -0.10 TEH TEC DSI 1.06 34 P1 04H

-0.02 TEH TEC MAI 0.19 84 6

04H 0.00 0.47 04H 04H DSI 0.63 48 P1 05H 0.03 TEH TEC DSI 0.60 63 P1 01H 0.07 TEH TEC DSI 0.47 50 P1 04H 0.08 TEH TEC DSI 0.72 62 P1 01H 0.05 TEH TEC DSI 0.59 27 P1 02H 0.10 TEH TEC SCI 0.27 28 P2 TSH

-0.03 110 TSH TSH DSI 0.82 116 P1 01H

-0.17 TEH TEC MAI 0.26 89 6

01H

-0.17 0.36 01H 01H MAI 0.28 107 6

01H 0.14 0.30 01H 01H DSI 0.78 59 P1 02H

-0.05 TEH TEC DSI 1.24 128 P1 03H

-0.02 TEH TEC DSI 0.41 128 P1 01H 0.05 TEH TEC DSI 1.17 68 P1 02H

-0.20 TEH TEC DSI 0.56 71 P1 02H

-0.07 TEH TEC DSI 0.58 46 P1 01H 0.10 TEH TEC DSI 1.06 88 P1 01H 0.15 TEH TEC MAI 0.40 107 6

01H 0.00 0.51 01H 01H DSI 0.89 87 P1 02H

-0.05 TEH TEC MAI 0.30 96 6

02H

-0.01 0.36 02H 02H DSI 1.09 53 P1 03H 0.02 TEH TEC DSI 1.29 65 P1 01H 0.07 TEH TEC

Beaver Valley Unit #1 Page 30 of 54 1 R1 5 S/G Examination Results 1RC-E-1A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 20 20 DSI 0.85 54 P1 03H 0.03 TEH TEC 20 21 DSI 1.65 90 P1 01H 0.17 TEH TEC 20 21 DSI 1.22 81 P1 02H 0.22 TEH TEC 20 21 SPR 2.03 101 P1 02H 0.00 TEH TEC 20 21 MAI 0.61 97 6

02H 0.13 0.45 02H 02H 20 21 DSI 0.69 147 P1 03H

-0.17 TEH TEC 20 21 SAI 0.28 90 6

03H

-0.05 0.44 03H 03H 20 21 DSI 0.89 100 P1 04H

-0.23 TEH TEC 20 22 DSI 0.44 67 P1 01H 0.05 TEH TEC 20 22 DSI 0.69 61 P1 02H

-0.12 TEH TEC 20 22 MAI 0.39 281 6

02H

-0.07 0.39 02H 02H 20 23 DSI 1.04 58 P1 01H 0.02 TEH TEC 20 26 DSI 1.76 20 P1 01H 0.00 TEH TEC 20 26 SPR 1.76 16 P1 01H 0.00 TEH TEC 20 26 SAI 0.37 99 6

01H

-0.02 0.21 01H 01H 20 28 DSI 0.53 139 P1 01C 0.10 1SH TEC 20 28 MAI 0.28 73 6

01C 0.14 0.33 01C 01C 20 28 DSI 0.93 94 P1 02H 0.34 1SH TEC 20 28 MAI 1.11 113 2

02H 0.16 0.31 02H 02H 20 28 DSI 0.69 115 P1 03H

-0.16 1SH TEC 20 28 SAI 0.84 116 2

03H

-0.17 0.31 03H 03H 20 28 DSI 0.54 149 P1 04H

-0.11 1SH TEC 20 28 SAI 1.18 97 2

04H

-0.25 0.49 04H 04H 20 28 DSI 0.49 92 P1 05H

-0.21 1SH TEC 20 28 SAI 1.04 103

,2 05H

-0.13 0.39 05H 05H 20 28 DSI 0.56 81 P1 06H 0.12 1SH TEC 20 28 MAI 0.32 127 6

TSH

-0.07 0.39 TSH TSH 20 30 DSI 0.50 46 P1 01H 0.02 TEH TEC 20 36 DSI 2.37 33 P1 01H 0.02 TEH TEC 20 36 SAI 1.00 55 6

01H 0.00 0.50 01H 01H 20 36 DSI 0.64 50 P1 02H

-0.25 TEH TEC 20 36 SAI 0.25 104 6

02H 0.05 0.42 02H 02H 20 36 SAI 2.19 32 6

TSH

-0.43 0.26 TSH TSH 20 37 DSI 0.49 126 P1 01H 0.12 TEH TEC 20 40 DSI 1.50 107 P1 01H 0.22 TEH TEC 20 40 DSI 0.83 100 P1 02H

-0.07 TEH TEC 20 41 DSI 0.47 80 P1 01H 0.05 TEH TEC 20 45 DSI 1.04 32 P1 02H 0.07 TEH TEC 20 45 SAI 0.25 86 6

02H

-0.01 0.24 02H 02H 20 47 DSI 0.56 107 P1 01H

-0.15 TEH TEC 20 47 SAI 0.15 105 6

01H 0.09 0.18 01H 01H 20 49 DSI 1.01 79 P1 01H 0.10 TEH TEC 20 50 DSI 0.68 67 P1 01H

-0.15 TEH TEC 20 50 SAI 0.17 99 6

01H

-0.14 0.58 01H 01H 20 53 DSI 0.74 86 P1 01H 0.22 TEH TEC 20 53 MAI 0.63 94 6

01H 0.00 0.32 01H 01H 20 54 DSI 1.38 82 P1 01H 0.05 TEH TEC 20 56 DSI 0.83 63 P1 01H 0.07 TEH TEC 20 57 DSI 0.84 36 P1 01H 0.02 TEH TEC 20 59 DSI 0.51 64 P1 02H 0.05 TEH TEC 20 59 SAI 0.27 116 6

02H 0.00 0.43 02H 02H

Beaver Valley Unit #1 Page 31 of 54 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 20 60 DSI 1.60 87 P1 02H

-0.14 1SH TEC 20 60 DSI 0.51 86 P1 03H 0.00 1SH TEC

20.

61 DSI 1.17 63 P1 01H 0.07 TEH TEC 20 61 DSI 1.01 128 P1 02H

-0.10 TEH TEC 20 61 SAI 0.37 109 6

02H 0.07 0.43 02H 02H 20 65 DSI 1.33 52 P1 01H 0.07 TEH TEC 20 65 DSI 0.40 107 P1 02H 0.07 TEH TEC 20 66 DSI 1.48 55 P1 01H 0.07 TEH TEC 20 67 DSI 0.19 75 P1 03H 0.02 TEH TEC 20 69 DSI 0.84 47 P1 01H 0.12 TEH TEC 20 70 DSI 0.26 93 P1 01H 0.00 TEH TEC 20 70 DSI 0.71 84 P1 02H

-0.02 TEH TEC 20 71 DS0 0.43 42 P1 01H 0.07 TEH TEC 20 72 DSI 0.85 31 P1 01H 0.07 TEH TEC 20 74 DSI 0.95 110 P1 01H

-0.05 TEH TEC 20 75 DSI 0.90 43 P1 02H 0.15 TEH TEC 20 76 DSI 0.48 124 P1 03H 0.25 TEH TEC 20 76 MAI 0.29 100 6

03H 0.10 0.48 03H 03H 20 78 DSI 0.78 51 P1 02H 0.03 TEH TEC 20 80 DSI 0.86 65 P1 01H

-0.02 TEH TEC 20 81 DSI 0.67 78 P1 02H 0.27 TEH TEC 20 81 SAI 0.32 60 6

02H 0.05 0.36 02H 02H 20 84 DSI 0.59 91 P1 02H 0.27 TEH TEC 20 84 SAI 0.33 84 6

02H 0.18 0.31 02H 02H 20 85 DSI 1.20 62 P1 01H 0.10 TEH TEC 20 88 DSI 0.53 65 P1 01H 0.00 TEH TEC 21 11 DSI 0.73 106 P1 01H 0.10 TEH TEC 21 11 MAI 0.32 93 6

01H 0.07 0.52 01H 01H 21 13 DSI 0.50 22 P1 01H 0.07 TEH TEC 21 18 DSI 0.51 144 P1 01H

-0.05 TEH TEC 21 18 DSI 0.72 89 P1 02H

-0.02 TEH TEC 21 21 DSI 0.97 57 P1 01H

-0.02 TEH TEC 21 21 DSI 0.31 136 P1 02H 0.07 TEH TEC 21 21 SPR 1.92 59 P1 02H 0.00 TEH TEC 21 21 SAI 0.18 91 6

02H 0.00 0.50 02H 02H 21 21 DSI 1.10 22 P1 03H 0.00 TEH TEC 21 21 SAI 0.12 96 6

03H

-0.02 0.25 03H 03H 21 21 SAI 0.13 113 6

03H 0.00 0.32 03H 03H 21 21 DSI 0.62 12 P1 04H

-0.07 TEH TEC 21 22 DSI 0.63 81 P1 01H 0.12 TEH TEC 21 28 DSI 0.79 56 P1 01H 0.07 TEH TEC 21 32 DSI 1.05 46 P1 01H 0.02 TEH TEC 21 32 MAI 0.33 96 6

01H

-0.01 0.29 01H 01H 21 33 DSI 2.17 48 P1 01H 0.00 TEH TEC 21 33 MAI 0.31 89 6

01H

-0.18 0.63 01H 01H 21 33 DSI 0.81 97 P1 02H

-0.10 TEH TEC 21 34 DSI 1.16 87 P1 01H 0.10 TEH TEC 21 35 DSI 0.55 74 P1 01H

-0.02 TEH TEC 21 37 DSI 1.23 79 P1 01H

-0.02 TEH TEC 21 38 DSI 0.76 16 P1 01H 0.05 TEH TEC 21 39 DSI 0.74 111 P1 01H 0.12 TEH TEC

Beaver Valley Unit #1 Page 32 of 54 1 R1 5 S/G Examination Results 1RC-E-1A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 21 39 DSI 0.57 134 P1 02H 0.22 TEH TEC 21 39 MAI 0.25 94 6

02H 0.22 0.58 02H 02H 21 40 DSI 0.66 84 P1 01 H 0.20 TEH TEC 21 42 DSI 1.88 66 P1 01H

-0.17 TEH TEC 21 44 DSI 1.23 27 P1 01H 0.05 TEH TEC 21 44 MAI 0.28 125 6

01H 0.05 0.50 01H 01H 21 44 DSI 0.88 19 P1 03H 0.10 TEH TEC 21 44 SAI 0.22 126 6

03H 0.01 0.47 03H 03H 21 45 DSI 1.40 51 P1 01H 0.05 TEH TEC 21 46 DSI 0.87 51 P1 01H

-0.02 TEH TEC 21 48 DSI 0.91 39 P1 01H 0.07 TEH TEC 21 50 DSI 0.53 69 P1 01H 0.07 TEH TEC 21 50 DSI 0.45 129 P1 02H 0.15 TEH TEC 21 50 SAI 0.19 99 6

02H 0.04 0.29 02H 02H 21 51 DSI 1.49 24 P1 01H 0.00 TEH TEC 21 51 MAI 0.30 107 6

01H 0.00 0.25 011H 01H 21 52 DSI 0.48 88 P1 01H 0.17 TEH TEC 21 52 DSI 0.82 95 P1 02H 0.08 TEH TEC 21 52 DSI 0.89 88 P1 05H 0.28 TEH TEC 21 52 SAI 0.24 123 6

05H 0.21 0.45 05H 05H 21 53 DSI 1.07 31 P1 01H 0.10 TEH TEC 21 53 SAI 0.40 95 6

011H 0.10 0.45 01H 01H 21 53 DNT 9.36 180 P1 03H 0.00 TEH TEC 21 53 MAI 0.21 67 6

03H 0.20 0.13 03H 03H 21 54 DSI 1.12 82 P1 01H

-0.05 TEH TEC 21 55 DSI 0.83 40 P1 011H 0.02 TEH TEC 21 55 SPR 1.63 155 P1 02H 0.00 TEH TEC 21 55 SAI 0.33 85 6

02H 0.12 0.21 02H 02H 21 57 DSI 1.13 68 P1 01H

-0.02 TEH TEC 21 58 DSI 0.36 67 P1 01H 0.10 TEH TEC 21 59 DSI 1.10 66 P1 01H 0.07 TEH TEC 21 59 DSI 0.29 40 P1 02H 0.00 TEH TEC 21 61 DSI 0.86 69 P1 01H 0.15 TEH TEC 21 62 DSI 1.04 78 P1 01H 0.00 TEH TEC 21 62 DSI 0.77 75 P1 02H

-0.15 TEH TEC 21 63 DSI 0.74 94 P1 01H

-0.10 TEH TEC 21 64 DSI 0.55 46 P1 01H 0.05 TEH TEC 21 64 DSI 0.64 66 P1 02H

-0.05 TEH TEC 21 66 DSI 0.60 91 P1 01H

-0.17 TEH TEC 21 66 DSI 0.82 37 P1 02H 0.05 TEH TEC 21 68 SPR 1.58 78 P1 03H 0.00 TEH TEC 21 68 MAI 0.27 85 6

03H 0.03 0.53 03H 03H 21 70 DSI 1.17 82 P1 02H 0.00 TEH TEC 21 71 DSI 0.43 65 P1 -

01H 0.07 TEH TEC 21 71 DSI 0.43 75 P1 01H 0.05 TEH TEC 21 72 DSI 0.71 86 P1 02H

-0.10 TEH TEC 21 74 PCT 1.13 34 18 P2 AV3

-0.25 TEH TEC 21 74 WAR 0.18 123 2

AV3

-0.02 07H 07C 21 74 PCT 1.28 21 19 P2 AV4

-0.33 TEH TEC 21 74 WAR 0.34 118 2

AV4

-0.56 07H 07C 21 75 DSI 0.78 67 P1 02H 0.25 TEH TEC

Beaver Valley Unit #1 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Page 33 of 54 Row Col 21 76 21 77 21 78 21 78 21 78 21 78 21 78 21 79 21 80 21 80 21 80 21 80 21 83 21 83 21 83 21 88 21 88 21 88 21 88 21 88 22 7

22 8

22 8

22 8

22 9

22 15 22 15 22 16 22 16 22 16 22 17 22 18 22 20 22 20 22 21 22 23 22 23 22 23 22 25 22 25 22 28 22 30 22 31 22 31 22 31 22 31 22 31 22 31 22 32 22 36 22 36 Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To PSI 15.79 164 8

02C 0.00 TEH TEC DSI 0.50 68 P1 01H 0.00 TEH TEC DSI 0.92 50 P1 01H 0.05 TEH TEC SAI 0.45 97 6

01H 0.05 0.16 01H 01H NQI 1.09 112 3

02H 5.87 TEH TEC DSI 1.71 67 P1 02H 0.20 TEH TEC SAI 0.45 99 6

02H 0.00 0.42 02H 03H DSI 0.23 52 P1 02H 0.02 TEH TEC DSI 0.80 59 P1 01H 0.08 TEH TEC DSI 1.63 89 P1 02H 0.27 TEH TEC MAI 0.87 87 6

02H 0.02 0.41 02H 02H DSI 0.60 39 P1 03H 0.03 TEH TEC DSI 1.38 79 P1 01H 0.17 TEH TEC DSI 0.79 55 P1 02H 0.17 TEH TEC SAI 0.27 102 6

02H 0.00 0.18 02H 02H PCT 0.38 0

25 3

01C 0.18 01C 01C VOL 0.39 57 3

01C 0.08 01C 01C PCT 0.21 0

18 3

02C 0.00 02C 02C VOL 0.18 63 3

02C -0.06 02C 02C DSI 0.73 62 P1 02H

-0.07 TEH TEC DSI 0.88 44 P1 01H 0.02 TEH TEC PCT 0.29 0

22 3

01C 0.05 01C 01C VOL 0.36 35 3

01C -0.12 01C 01C DSI 0.61 86 P1 01H 0.00 TEH TEC PCT 1.79 113 24 P1 01C 0.15 TEH TEC DSI 1.38 47 P1 02H

-0.12 TEH TEC SAI 0.19 116 6

02H 0.00 0.50 02H 02H NOI 0.56 117 3

01H 13.07 TEH TEC DSI 0.96 31 P1 02H 0.00 TEH TEC SAI 0.25 127 6

02H 0.00 0.49 01H 02H DSI 0.68 88 P1 02H 0.15 TEH TEC DSI 1.02 54 P1 01H 0.02 TEH TEC DSI 0.53 83 P1 01H 0.22 TEH TEC DSI 0.62 63 P1 02H

-0.05 TEH TEC DSI 1.85 85 P1 01H 0.02 TEH TEC DSI 1.28 27 P1 01H 0.02 TEH TEC SAI 0.54 93 6

01H 0.03 0.43 01H 01H DSI 0.86 80 P1 02H

-0.05 TEH TEC DSI 1.07 41 P1 01H

-0.02 TEH TEC SAI 0.85 85 6

01H 0.09 0.43 01H 01H DSI 0.56 50 P1 01H 0.07 TEH TEC DSI 0.56 59 P1 01H

-0.02 TEH TEC DSI 0.59 108 P1 02H

-0.16 1SH TEC SAI 0.62 86 2

02H

-0.10 0.53 02H 02H PCT 2.39 30 28 P2 AV2 0.29 1SH TEC WAR 0.53 117 2

AV2 0.02 07C 07H PCT 1.77 19 23 P2 AV3 0.29 1SH TEC WAR 0.49 114 2

AV3

-0.01 07C 07H DSI 0.45 57 P1 01H 0.02 TEH TEC DSI 1.93 50 P1 01H 0.07 TEH TEC MAI 1.99 57 6

01H 0.03 0.50 01H 01H

Beaver Valley Unit #1 Page 34 of 54 1 R15 S/G Examination Results I RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inchl Cr-Length Cr-Angle From To 22 39 DSI 0.48 39 P1 01H 0.00 TEH TEC 22 40 DSI 1.57 107 P1 01H

-0.12 TEH TEC 22 41 DSI 0.41 47 P1 01H

-0.02 TEH TEC 22 43 DSI 0.94 69 P1 01H 0.00 TEH TEC 22 43 MAI 0.43 109 6

01H 0.00 0.35 01H 01H 22 44 DSI 0.93 45 P1 01H 0.05 TEH TEC 22 44 SAI 0.46 97 6

01H 0.05 0.25 01H 01H 22

45.

DSI 1.24 107 P1 01H

-0.10 TEH TEC 22 45 SAI 0.91 97 6

01H -0.10 0.39 01H 01H 22 47 DSI 0.73 123 P1 01H

-0.05 TEH TEC 22 47 DSI 0.43 45 P1 02H 0.07 TEH TEC 22 48 DSI 0.62 151 P1 01H

-0.20 TEH TEC 22 49 DSI 0.52 43 P1 O1H 0.05 TEH TEC 22 50 DSI 0.41 61 P1 01H 0.02 TEH TEC 22 54 DSI 0.61 29 P1 01H 0.00 TEH TEC 22 58 DSI 0.86 70 P1 01H

-0.07 TEH TEC 22 59 DSI 0.66 98 P1 01H -0.17 TEH TEC 22 63 DSI 0.60 58 P1 01H 0.02 TEH TEC 22 68 DSI 1.16 91 P1 02H 0.24 1SH TEC 22 68 SPR 1.73 88 P1 02H 0.00 1SH TEC 22 68 SAI 1.15 103 2

02H 0.07 0.64 02H 02H 22 69 DSI 1.02 66 P1 02H

-0.05 1SH TEC 22 73 DSI 0.57 103 P1 02H 0.00 TEH TEC 22 74 DSI 1.59 94 P1 02H 0.21 1SH TEC 22 78 DSI 0.49 43 P1 01H 0.10 TEH TEC 22 81 DSI 0.81 41 P1 01H 0.00 TEH TEC 22 82 DSI 0.38 112 P1 01H 0.10 TEH TEC 22 85 DSI 0.82 48 P1 02H 0.05 TEH TEC 22 87 DSI 0.88 35 P1 02H 0.12 TEH TEC 23 7

DSI 1.48 9

P1 02H 0.05 TEH TEC 23 7

SPR 1.65 156 P1 02H 0.00 TEH TEC 23 7

SAI 0.19 110 6

02H 0.00 0.36 02H 02H 23 8

PCT 0.39 0

25 3

01C 0.09 01C 01C 23 8

VOL 0.40 65 3

01C -0.06 01C 01C 23 9

DSI 1.18 103 P1 01H 0.15 TEH TEC 23 9

DSI 0.68 38 P1 03H 0.03 TEH TEC 23 10 SPR 1.97 162 P1 01H 0.00 TEH TEC 23 10 SAI 0.44 96 6

01H 0.12 0.48 01H 01H 23 13 DSI 0.53 33 P1 01H 0.07 TEH TEC 23 13 DSI 0.88 49 P1 02H 0.02 TEH TEC 23 20 DSI 0.79 99 P1 01H 0.12 TEH TEC 23 22 DSI 0.80 48 P1 01H 0.07 TEH TEC 23 23 DSI 1.17 99 P1 01H 0.07 TEH TEC 23 24 DSI 0.62 102 P1 02H

-0.07 TEH TEC 23 24 SAI 0.50 124 6

02H

-0.06 0.23 02H 02H 23 25 DSI 0.65 37 P1 01H

-0.02 TEH TEC 23 29 DSI 1.38 77 P1 01H 0.03 2SH TEH 23 29 DSI 1.04 72 P1 03H

-0.19 2SH TEC 23 34 DSI 0.74 58 P1 01H 0.00 TEH TEC 23 34 DSI 0.45 96 P1 02H 0.25 TEH TEC 23 35 DSI 0.63 39 P1 01H 0.05 TEH TEC

Beaver Valley Unit #1 Page 35 of 54 1 R15 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inchl Cr-Length Cr-Angle From To 23 35 SAI 0.27 88 6

01H

-0.13 0.24 01H 01H 23 36 DSI 0.35 101 P1 01H

-0.05 TEH TEC 23 36 DSI 0.32 100 P1 02H

-0.07 TEH TEC 23 36 SAI 0.40 141 6

TSH

-0.05 0.29 TSH TSH 23 38 DSI 0.64 37 P1 01H 0.07 TEH TEC 23 42 DSI 1.72 99 P1 01H

-0.02 TEH TEC 23 43 DSI 0.52 127 P1 01H 0.00 TEH TEC 23 47 DSI 0.81 115 P1 01H

-0.05 TEH TEC 23 47 MAI 0.39 97 6

01H

-0.01 0.38 01H 01H 23 51 DSI 0.60 43 P1 01H 0.00 TEH TEC 23 56 DSI 1.08 77 P1 01H

-0.10 TEH TEC 23 56 DSI 0.37 72 P1 03H 0.05 TEH TEC 23 56 SAI 0.19 115 6

03H

-0.07 0.48 03H 03H 23 57 DSI 0.74 77 P1 01H 0.05 TEH TEC 23 62 DSI 0.84 50 P1 01H 0.10 TEH TEC 23 65 DSI 0.51 141 P1 01H 0.22 TEH TEC 23 65 DSI 0.33 65 P1 03H 0.12 TEH TEC 23 66 DSI 0.58 72 P1 02H

-0.05 TEH TEC 23 67 DSI 1.08 49 P1 01H 0.07 TEH TEC 23 67 MAI 0.35 99 6

01H 0.07 0.45 01H 01H 23 67 DSI 0.77 41 P1 02H 0.12 TEH TEC 23 69 DSI 0.20 80 P1 02H 0.00 TEH TEC 23 70 DSI 0.66 93 P1 01H 0.17 TEH TEC 23 70 MAI 0.42 81 6

01H 0.00 0.70 01H 01H 23 70 DSI 0.23 88 P1 02H

-0.07 TEH TEC 23 71 DSI 0.96 84 P1 01H 0.22 TEH TEC 23 78 DSI 0.45 29 P1 01H 0.05 TEH TEC 23 78 DSI 0.86 45 P1 02H 0.08 TEH TEC 24 8

VOL 0.33 63 3

01C 0.00 01C 01C 24 8

PCT 0.35 0

24 3

01C

-0.03 01C 01C 24 8

VOL 0.56 71 3

02C

-0.09 02C 02C 24 8

PCT 0.61 0

32 3

02C 0.06 02C 02C 24 11 DSI 0.94 39 P1 05H 0.03 TEH TEC 24 12 DSI 0.55 22 P1 03H 0.05 TEH TEC 24 16 DSI 0.54 42 P1 01H 0.07 TEH TEC 24 17 DSI 0.26 34 P1 01H 0.00 TEH TEC 24 18 DSI 0.29 96 P1 02H 0.00 TEH TEC 24 21 DSI 0.71 44 P1 01H 0.00 TEH TEC 24 22 DSI 0.72 31 P1 01H 0.05 TEH TEC 24 24 DSI 0.69 41 P1 01H

-0.10 TEH TEC 24 27 DSI 0.58 74 P1 01H 0.00 TEH TEC 24 31 DSI 1.51 83 P1 01H 0.10 TEH TEC 24 35 DSI 0.77 35 P1 011H 0.02 TEH TEC 24 35 MAI 0.37 95 6

011H

-0.06 0.55 01H 01H 24 35 DSI 0.38 40 P1 02H 0.00 TEH TEC 24 35 SAI 0.24 81 6

02H 0.06 0.50 02H 02H 24 38 DSI 0.36 58 P1 01H 0.15 TEH TEC 24 40 DSI 0.67 118 P1 011H 0.02 TEH TEC 24 40 SAI 0.18 61 6

01H

-0.09 0.20 01H 01H 24 40 DSI 1.29 90 P1 02H

-0.05 TEH TEC 24 40 DSI 0.36 60 P1 04H

-0.13 TEH TEC

Beaver Valley Unit #1 Page 36 of 54 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 24 41 DSI 0.89 52 P1 01 H 0.07 TEH TEC 24 44 DSI 0.79 111 P1 02H

-0.07 TEH TEC 24 45 DSI 1.56 23 P1 02H 0.00 TEH TEC 24 45 SAI 0.56 100 6

02H 0.00 0.34 02H 02H 24 45 DSI 0.61 32 P1 03H 0.27 TEH TEC 24 46 DSI 0.60 59 P1 011H 0.05 TEH TEC 24 46 MAI 0.37 115 6

O1H 0.00 0.65 01H 01H 24 51 PCT 2.28 0

27 P2 AV1 0.00 TEH TEC 24 51 WAR 0.61 130 P2 AV1 0.00 07C 07H 24 51 PCT 1.72 0

22 P2 AV2 0.00 TEH TEC 24 51 WAR 0.37 137 P2 AV2 0.00 07C 07H 24 51 PCT 1.17 0

17 P2 AV3 0.00 TEH TEC 24 51 WAR 0.34 134 P2 AV3 0.00 07C 07H 24 51 PCT 1.85 0

24 P2 AV4 0.00 TEH TEC 24 51 WAR 0.51 131 P2 AV4 0.00 07C 07H 24 52 DSI 0.45 51 P1 01H 0.02 TEH TEC 24 53 DSI 0.75 119 P1 02H

-0.13 TEH TEC 24 53 NOI 0.42 103 3

06H 11.52 TEH TEC 24 53 NOI 0.31 104 3

06H 43.09 TEH TEC 24 54 DSI 0.88 54 P1 01H 0.07 TEH TEC 24 54 DSI 0.61 112 P1 02H

-0.15 TEH TEC 24 55 DSI 0.45 75 P1 01H

-0.03 STH TEC 24 57 DSI 0.43 118 P1 01H 0.15 TEH TEC 24 57 SAI 0.35 78 6

01H 0.06 0.39 01H 01H 24 58 DSI 0.95 52 P1 02H 0.02 TEH TEC 24 60 DSI 1.26 80 P1 01H 0.17 TEH TEC 24 60 DSI 0.60 105 P1 02H

-0.05 TEH TEC 24 64 DSI 0.46 109 P1 02H

-0.05 TEH TEC 24 66 DSI 1.01 100 P1 01H

-0.15 TEH TEC 24 66 DSI 0.46 135 P1 02H 0.00 TEH TEC 24 68 PCT 1.20 0

21 P2 AV2

-0.08 TEH TEC 24 68 WAR 0.30 144 2

AV2 0.00 07C 07H 24 69 DSI 0.56 120 P1 02H 0.25 TEH TEC 24 69 SAI 0.14 107 6

02H

-0.12 0.12 01H 02H 24 70 DSI 0.69 64 P1 02H 0.00 TEH TEC 24 72 DSI 1.07 92 P1 04H 0.26 2SH TEC 24 72 SPR 1.54 105 P1 04H 0.00 2SH TEC 24 72 SAI 1.42 90 2

04H 0.25 0.26 04H 04H 24 73 DSI 0.59 135 P1 01H

-0.15 TEH TEC 24 73 MAI 0.24 99 6

01H

-0.09 0.50 011H 01H 24 73 DSI 0.87 37 P1 02H 0.05 TEH TEC 24 74 DSI 0.24 64 P1 01H 0.00 TEH TEC 24 74 DSI 0.85 103 P1 02H

-0.10 TEH TEC 24 79 DSI 2.10 52 P1 02H 0.15 TEH TEC 24 79 MAI 0.56 91 6

02H

-0.07 0.39 02H 02H 24 84 DSI 0.64 95 P1 01H 0.23 TEH TEC 24 86 DNI 0.34 155 5

06C 34.10 TEH TEC 25 11 PCT 0.64 0

33 3

01C 0.09 01C 01C 25 11 VOL 0.56 73 3

01C 0.01 01C 01C 25 12 DSI 0.64 41 P1 01H

-0.02 TEH TEC 25 12 DSI 0.60 46 P1 05H

-0.05 TEH TEC

Beaver Valley Unit #1 Page 37 of 54 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 25 14 DSI 0.76 33 P1 01H

-0.02 TEH TEC 25 14 DSI 1.13 83 P1 02H 0.15 TEH TEC 25 14 DSI 0.90 52 P1 03H 0.00 TEH TEC 25 19 DSI 0.65 73 P1 02H 0.00 TEH TEC 25 19 DSI 1.12 50 P1 03H 0.00 TEH TEC 25 19 SAI 0.22 86 6

03H 0.00 0.14 03H 03H 25 20 DSI 0.60 33 P1 01H

-0.07 TEH TEC 25 21 DSI 0.59 95 P1 01H 0.02 TEH TEC 25 22 DSI 1.09 41 P1 01H 0.10 TEH TEC 25 22 SAI 0.35 91 6

01H 0.03 0.45 01H 01H 25 22 DSI 0.31 91 P1 03H 0.13 TEH TEC 25 24 DSI 0.68 86 P1 01H

-0.02 TEH TEC 25 27 DSI 0.74 127 P1 01H

-0.10 TEH TEC 25 27 SAI 0.36 111 6

01H

-0.06 0.56 01H 01H 25 27 DSI 0.41 70 P1 02H 0.05 TEH TEC 25 27 SAI 0.39 110 6

02H 0.00 0.44 02H 02H 25 32 DSI 0.89 42 P1 01H 0.05 TEH TEC 25 32 NQI 0.58 116 3

06C 36.98 TEH TEC 25 36 DSI 0.98 47 P1 01H 0.07 TEH TEC 25 36 SAI 0.49 107 6

01H

-0.06 0.41 01H 01H 25 36 DSI 0.40 69 P1 02H 0.08 TEH TEC 25 36 SAI 0.15 107 6

TSH

-0.24 0.29 TSH TSH 25 38 DSI 0.47 46 P1 02H 0.03 TEH TEC 25 39 DSI 0.68 114 P1 01H

-0.07 TEH TEC 25 39 SAI 0.29 114 6

01H

-0.01 0.45 01H 01H 25 40 DSI 0.77 108 P1 02H

-0.17 TEH TEC 25 40 SAI 0.19 112 6

02H

-0.13 0.39 02H 02H 25 41 DSI 0.78 76 P1 01H 0.07 TEH TEC 25 41 SAI 0.26 119 6

01H 0.07 0.32 01H 01H 25 42 DSI 0.48 124 P1 01H 0.07 TEH TEC 25 42 DSI 0.50 49 P1 02H 0.07 TEH TEC 25 42 DSI 0.19 39 P1 05H 0.00 TEH TEC 25 43 DSI 0.57 69 P1 01H 0.00 TEH TEC 25 43 PCT 1.01 0

15 P2 AV2 0.00 TEH TEC 25 43 WAR 0.08 155 2

AV2

-0.12 07C 07H 25 43 WAR 0.19 35 2

AV2

-0.12 07C 07H 25 43 PCT 0.92 0

14 P2 AV3 0.00 TEH TEC 25 43 WAR 0.14 160 2

AV3 0.06 07C 07H 25 43 WAR 0.14 112 2

AV3 0.06 07C 07H 25 45 DSI 0.70 44 P1 01H 0.10 TEH TEC 25 46 DSI 0.63 75 P1 01H 0.10 TEH TEC 25 48 DSI 1.21 75 P1 01H

-0.02 TEH TEC 25 48 DSI 0.60 78 P1 02H 0.03 TEH TEC 25 50 DSI 0.58 140 P1 01H

-0.27 TEH TEC 25 50 DSI 0.92 133 P1 02H

-0.10 TEH TEC 25 50 SAI 0.22 120 6

02H

-0.16 0.50 02H 02H 25 50 DSI 0.35 39 P1 05H 0.03 TEH TEC 25 51 DSI 1.54 105 P1 01H

-0.02 TEH TEC 25 53 DSI 0.53 75 P1 01H 0.10 TEH TEC 25 55 DSI 0.27 48 P1 02H 0.02 TEH TEC 25 55 DSI 0.37 61 P1 03H 0.00 TEH TEC

Beaver Valley Unit #1 Page 38 of 54 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 25 59 DSI 0.70 79 P1 01H 0.02 TEH TEC 25 59 DSI 0.64 76 P1 02H

-0.05 TEH TEC 25 61 DSI 1.38 91 P1 01H 0.12 TEH TEC 25 64 DSI 0.63 64 P1 01H 0.07 TEH TEC 25 65 PCT 3.30 0

34 P2 AV3 0.00 TEH TEC 25 65 WAR 0.81 111 2

AV3 0.00 07C 07H 25 65 PCT 3.21 0

33 P2 AV4 0.00 TEH TEC 25 65 WAR 0.69 108 2

AV4 0.00 07C 07H 25 66 DSI 0.78 58 P1 01 H 0.07 TEH TEC 25 71 DSI 0.71 31 P1 02H 0.10 TEH TEC 25 78 DSI 0.76 37 P1 02H 0.10 TEH TEC 25 78 DSI 1.35 43 P1 04H 0.03 TEH TEC 25 78 SAI 0.27 113 6

04H 0.03 0.36 04H 04H 25 78 SCI 0.16 65 P2 TSH

-0.20 93 TSH TSH 25 79 DSI 1.52 76 P1 01H 0.07 TEH TEC 25 79 SPR 1.65 76 P1 01H 0.00 TEH TEC 25 79 MAI 0.61 94 6

01 H 0.06 0.34 01 H 01 H 25 79 DSI 0.81 30 P1 02H 0.05 TEH TEC 25 79 DSI 0.40 31 P1 07C

-0.05 TEH TEC 25 81 DS0 1.20 46 P1 01H 0.02 TEH TEC 25 81 MAI 0.29 98 6

01H 0.05 0.35 01H 01H 25 82 SCI 0.40 76 P2 TSH

-0.14 165 TSH TSH 25 86 DSI 0.73 113 P1 02H 0.18 TEH TEC 26 11 DSI 1.67 76 P1 01H

-0.03 TEH TEC 26 11 DSI 0.99 57 P1 03H 0.05 TEH TEC 26 13 DSI 0.48 144 P1 01H 0.02 TEH TEC 26 18 DSI 0.21 89 P1 02H 0.05 TEH TEC 26 23 DSI 0.83 34 P1 01 H 0.05 TEH TEC 26 26 DSI 0.86 65 P1 01 H 0.05 TEH TEC 26 29 DSI 0.53 71 P1 01H 0.10 TEH TEC 26 30 DSI 1.06 69 P1 01H 0.05 TEH TEC 26 30 DSI 0.26 47 P1 02H 0.05 TEH TEC 26 32 DSI 1.49 113 P1 01H 0.20 TEH TEC 26 32 DSI 0.98 137 P1 02H

-0.07 TEH TEC 26 33 DSI 0.55 44 P1 01H 0.07 TEH TEC 26 34 PCT 0.58 0

12 P2 AV1

-0.13 TEH TEC 26 34 WAR 0.21 134 2

AV1

-0.70 07C 07H 26 34 PCT 1.31 0

21 P2 AV2

-0.25 TEH TEC 26 34 WAR 0.26 130 2

AV2

-0.11 07C 07H 26 34 PCT 1.07 0

19 P2 AV3 0.00 TEH TEC 26 34 WAR 0.34 126 2

AV3 0.01 07C 07H 26 34 PCT 1.77 0

26 P2 AV4 2.10 TEH TEC 26 34 PCT 2.58 0

31 P2 AV4

-1.99 TEH TEC 26 34 WAR 0.73 115 2

AV4

-1.96 07C 07H 26 34 WAR 0.48 113 2

AV4 2.10 07C 07H 26 35 DSI 0.81 115 P1 01H 0.22 TEH TEC 26 35 SAI 0.29 95 6

011H 0.07 0.50 01H 01H 26 36 DSI 0.64 69 P1 01H 0.10 TEH TEC 26 50 DSI 0.43 39 P1 01H 0.02 TEH TEC 26 51 DSI 1.90 107 P1 01H 0.17 TEH TEC 26 55 DSI 0.90 52 P1 01H 0.05 TEH TEC

Beaver Valley Unit #1 Page 39 of 54 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 26 62 DSI 0.99 84 P1 02H

-0.11 1SH TEC 26 65 DSI 0.48 68 P1 01H 0.07 TEH TEC 26 65 DSI 0.66 71 P1 02H 0.07 TEH TEC 26 67 DSI 1.14 47 P1 011H 0.07 TEH TEC 26 67 MAI 0.31 108 6

01H 0.07 0.27 01H 01H 26 67 DSI 1.61 49 P1 02H 0.10 TEH TEC 26 67 MAI 0.26 107 6

02H 0.03 0.26 02H 02H 26 70 DSI 0.59 42 P1 01H 0.00 TEH TEC 26 82 DSI 0.67 32 P1 02H 0.15 TEH TEC 27 10 DSI 0.36 29 P1 01H 0.00 TEH TEC 27 14 DSI 0.60 60 P1 01H 0.00 TEH TEC 27 15 DSI 0.72 49 P1 01H 0.00 TEH TEC 27 19 DSI 0.70 49 P1 01H 0.00 TEH TEC 27 19 DSI 0.56 66 P1 02H 0.10 TEH TEC 27 21 DSI 0.98 136 P1 01H 0.22 TEH TEC 27 21 DSI 0.60 72 P1 02H 0.07 TEH TEC 27 23 DSI 0.30 87 P1 01H 0.05 TEH TEC 27 23 SAI 0.22 118 6

01H

-0.05 0.50 01H 01H 27 26 DSI 0.91 67 P1 03H 0.03 TEH TEC 27 27 DSI 1.12 47 P1 01H 0.02 TEH TEC 27 27 DSI 0.66 31 P1 03H 0.10 TEH TEC 27 27 DNI 1.76 119 5

AV4 17.14 TEH TEC 27 31 DSI 0.66 72 P1 01H 0.02 TEH TEC 27 31 SAI 0.46 99 6

O1H

-0.08 0.20 01H 01H 27 32 DSI 0.80 74 P1 01H 0.12 TEH TEC 27 33 DSI 0.43 135 P1 01H 0.10 TEH TEC 27 34 DSI 1.31 98 P1 03H 0.29 2SH TEC 27 34 WAR 0.28 121 2

AV1 0.00 07C 07H 27 34 WAR 0.30 122 2

AV2 0.00 07C 07H 27 37 DSI 0.92 43 P1 011H 0.00 TEH TEC 27 37 SAI 0.53 101 6

011H 0.00 0.41 01H 01H 27 38 DSI 0.76 41 P1 01H 0.00 TEH TEC 27 38 DSI 0.45 39 P1 02H 0.03 TEH TEC 27 40 DSI 0.86 123 P1 01H 0.11 STH TEC 27 40 DSI 0.87 103 P1 02H

-0.03 STH TEC 27 44 DSI 1.01 98 P1 01H 0.00 TEH TEC 27 45 DSI 0.96 20 P1 01H 0.00 TEH TEC 27 53 DSI 0.85 105 P1 01H 0.15 TEH TEC 27 54 DSI 1.12 54 P1 01H 0.12 TEH TEC 27 59 DSI 1.05 41 P1 01H 0.07 TEH TEC 27 59 SAI 0.31 99 6

011H 0.07 0.29 01H 01H 27 59 DSI 0.80 56 P1 02H 0.07 TEH TEC 27 63 DSI 1.02 45 P1 01H 0.07 TEH TEC 27 63 MAI 1.11 76 6

01H

-0.02 0.45 01H 01H 27 66 DSI 1.07 54 P1 01H 0.02 TEH TEC 27 66 DSI 0.31 20 P1 02H 0.03 TEH TEC 27 67 DSI 0.38 129 P1 02H 0.05 TEH TEC 27 73 DSI 0.74 40 P1 02H 0.00 TEH TEC 27 73 DSI 0.50 41 P1 04H 0.00 TEH TEC 27 73 SAI 0.16 116 6

04H 0.00 0.20 04H 04H 27 75 DSI 0.83 123 P1 04H

-0.05 TEH TEC

Beaver Valley Unit #1 Page 40 of 54 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 27 79 DSI 0.53 55 P1 02H 0.10 TEH TEC 27 84 DSI 0.27 62 P1 01H 0.05 TEH TEC 27 85 VOL 1.03 47 3

02C 0.07 02C 02C 27 85 PCT 0.80 0

36 3

02C 0.02 02C 02C 28 12 PCT 0.50 131 1

P1 03C 0.10 TEH TEC 28 13 PCT 1.03 123 6

P1 02C -0.07 TEH TEC 28 14 DSI 0.67 117 P1 01H 0.05 TEH TEC 28 15 DSI 0.50 39 P1 01H 0.12 TEH TEC 28 17 DSI 0.84 55 P1 01H 0.07 TEH TEC 28 17 DSI 0.29 50 P1 02H

-0.02 TEH TEC 28 17 DSI 0.57 28 P1 03H 0.05 TEH TEC 28 21 DSI 1.12 96 P1 01H 0.05 TEH TEC 28 21 DSI 1.47 87 P1 02H 0.10 TEH TEC 28 21 DSI 1.18 104 P1 03H

-0.20 TEH TEC 28 21 SPR 1.64 99 P1 03H 0.00 TEH TEC 28 21 SAI 0.36 96 6

03H

-0.16 0.25 03H 03H 28 27 DSI 0.80 35 P1 01H 0.05 TEH TEC 28 28 DSI 0.56 136 P1 02H 0.03 TEH TEC 28 29 DSI 0.37 158 P1 01H

-0.22 TEH TEC 28 29 MAI 0.22 96 6

01H

-0.04 0.38 01H 01H 28 32 DSI 0.82 44 P1 01H 0.07 TEH TEC 28 32 DSI 0.52 106 P1 02H 0.05 TEH TEC 28 34 DSI 0.15 53 P1 03H 0.08 TEH TEC 28 36 DSI 0.61 62 P1 01H

-0.05 STH TEC 28 36 DSI 0.79 125 P1 02H 0.05 STH TEC 28 37 DSI 0.42 77 P1 01H 0.00 TEH TEC 28 40 DSI 0.31 70 P1 02H 0.15 TEH TEC 28 41 DSI 1.12 85 P1 01H 0.10 TEH TEC 28 41 DSI 1.28 100 P1 02H

-0.15 TEH TEC 28 43 DSI 0.87 79 P1 01H 0.15 TEH TEC 28 44 DSI 0.37 107 P1 02H 0.02 TEH TEC 28 45 DSI 0.95 63 P1 01H 0.12 TEH TEC 28 45 DSI 0.77 44 P1 02H 0.02 TEH TEC 28 46 DSI 0.98 103 P1 01H

-0.15 TEH TEC 28 46 DSI 0.79 77 P1 02H 0.12 TEH TEC 28 48 DSI 1.05 51 P1 01H 0.10 TEH TEC 28 50 DSI 0.92 68 P1 01H 0.15 TEH TEC 28 50 SAI 0.40 106 6

01H 0.01 0.55 01H 01H 28 53 DSI 0.77 18 P1 02H

-0.02 TEH TEC 28 53 SAI 0.16 95 6

02H

-0.02 0.39 02H 02H 28 54 DSI 0.51 62 P1 01H 0.00 TEH TEC 28 56 DSI 0.73 115 P1 01H 0.10 TEH TEC 28 56 SAI 0.35 95 6

O1H 0.10 0.43 01H 01H 28 57 DSI 0.82 30 P1 01H 0.02 TEH TEC 28 57 DSI 1.08 46 P1 02H 0.00 TEH TEC 28 57 SAI 0.17 110 6

02H 0.00 0.23 02H 02H 28 60 DSI 0.93 141 P1 02H 0.28 1SH TEC 28 60 SAI 0.75 114 2

02H 0.14 0.37 02H 02H 28 60 DSI 0.46 83 P1 03H 0.06 1SH TEC 28 61 DSI 0.56 39 P1 01H 0.02 TEH TEC 28 62 DSI 0.25 98 P1 01H 0.07 TEH TEC

Beaver Valley Unit #1 Page 41 of 54 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inchl Cr-Length Cr-Angle From To 28 63 DSI 1.01 106 P1 01H 0.07 TEH TEC 28 63 SAI 0.63 95 6

01H 0.07 0.43 01H 01H 28 63 DSI 0.49 97 P1 02H

-0.05 TEH TEC 28 64 DSI 0.55 24 P1 01H 0.02 TEH TEC 28 64 SAI 0.39 108 6

01H

-0.03 0.56 01H 01H 28 67 DSI 0.41 67 P1 02H 0.10 TEH TEC 28 68 DSI 0.79 45 P1 02H 0.15 TEH TEC 28 69 DSI 0.82 57 P1 02H 0.10 TEH TEC 28 69 MAI 0.29 100 6

02H 0.03 0.24 02H 02H 28 71 DSI 0.53 89 P1 01H 0.07 TEH TEC 28 71 DSI 0.62 41 P1 02H 0.05 TEH TEC 28 71 DSI 0.56 49 P1 03H 0.00 TEH TEC 28 72 DSI 0.86 45 P1 01H 0.00 TEH TEC 28 75 DSI 0.62 19 P1 02H 0.02 TEH TEC 28 78 DSI 0.25 38 P1 01H 0.10 TEH TEC 28 79 DSI 0.65 103 P1 01H

-0.05 TEH TEC 28 83 DSI 0.45 52 P1 04H 0.00 TEH TEC 28 84 PCT 0.54 128 12 P1

'01C

-0.20 TEH TEC 28 85 VOL 0.18 65 3

01C 0.08 01C 01C 28 85 PCT 0.32 0

23 3

01C 0.01 01C 01C 29 14 PCT 0.91 120 18 P1 01C -0.28 TEH TEC 29 15 DSI 1.22 129 P1 02H 0.23 TEH TEC 29 15 DSI 0.44 63 P1 03H 0.03 TEH TEC 29 21 DSI 1.08 64 P1 01H 0.05 TEH TEC 29 21 DSI 0.98 72 P1 02H 0.05 TEH TEC 29 21 DSI 0.59 71 P1 03H 0.05 TEH TEC 29 23 DSI 1.01 55 P1 01H 0.10 TEH TEC 29 23 DSI 1.08 73 P1 02H 0.02 TEH TEC 29 26 SPR 1.51 82 P1 01H 0.00 TEH TEC 29 26 SVI 0.46 102 6

01H

-0.06 0.64 60 01H 01H 29 28 DSI 0.41 14 P1 02H 0.15 TEH TEC 29 28 DSI 0.98 38 P1 03H 0.00 TEH TEC 29 28 SAI 0.52 86 6

03H

-0.16 0.38 03H 03H 29 32 DNT 2.91 184 P1 02H

-0.10 TEH TEC 29 32 SAI 0.17 94 6

.02H 0.10 0.24 02H 02H 29 34 PCT 1.23 0

21 P2 AV3

-0.30 TEH TEC 29 34 WAR 0.34 118 2

AV3

-0.13 07H 07C 29 34 PCT 2.89 0

33 P2 AV4 0.00 TEH TEC 29 34 WAR 0.51 126 2

AV4

-0.01 07H 07C 29 36 DSI 1.08 43 P1 01H 0.00 TEH TEC 29 36 MAI 0.30 119 6

01H 0.00 0.50 01H 01H 29 36 DSI 1.60 21 P1 02H 0.03 TEH TEC 29 36 SAI 0.21 89 6

02H

-0.04 0.41 02H 02H 29 41 DSI 1.20 41 P1 01H 0.05 STH TEC 29 43 PCT 1.35 0

19 P2 AV4 0.00 TEH TEC 29 43 WAR 0.22 142 2

AV4 0.28 07H 07C 29 44 DSI 1.28 76 P1 01H 0.02 TEH TEC 29 46 DSI 1.08 36 P1 01H

-0.05 TEH TEC 29 46 MAI 0.42 82 6

01H 0.02 0.30 01H 01H 29 47 DSI 0.68 49 P1 01H 0.00 TEH TEC 29 47 DSI 0.43 11 P1 04H

-0.02 TEH TEC

Beaver Valley Unit #1 Page 42 of 54 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 29 50 DSI 0.44 80 P1 01H 0.07 TEH TEC 29 51 DSI 0.80 73 P1 01H 0.00 TEH TEC 29 51 SAI 0.81 99 6

01H 0.00 0.43 01H 01H 29 52 DSI 0.53 65 P1 02H 0.02 TEH TEC 29 54 DSI 0.44 32 P1 01H

-0.02 TEH TEC 29 59 DSI 1.53 105 P1 O1H 0.10 TEH TEC 29 59 DSI 1.29 96 P1 02H 0.10 TEH TEC 29 60 DSI 1.06 74 P1 01H 0.02 TEH TEC 29 60 PCT 4.08 0

38 P2 AV2 0.58 TEH TEC 29 60 WAR 0.88 110 2

AV2 0.29 07H 07C 29 60 PCT 5.45 0

42 P2 AV3 0.00 TEH TEC 29 60 WAR 1.27 98 2

AV3 0.36 07H 07C 29 60 PCT 1.17 0

17 P2 AV4 0.00 TEH TEC 29 60 WAR 0.50 136 2

AV4 0.50 07H 07C 29 61 DSI 1.12 62 P1 01H 0.05 TEH TEC 29 61 DSI 0.41 113 P1 02H 0.00 TEH TEC 29 62 DSI 0.52 109 P1 01H 0.15 TEH TEC 29 62 DSI 0.58 157 P1 02H

-0.05 TEH TEC 29 62 DSI 0.80 93 P1 03H

-0.27 TEH TEC 29 62 MAI 0.23 112 6

03H

-0.02 0.48 03H 03H 29 63 DSI 0.89 89 P1 01H 0.07 TEH TEC 29 63 DSI 1.58 78 P1 02H

-0.12 TEH TEC 29 63 DSI 0.77 122 P1 03H 0.25 TEH TEC 29 64 DSI 0.95 50 P1 01H 0.00 TEH TEC 29 64 SAI 0.45 90 6

01H 0.00 0.41 01H 01H 29 67 DSI 0.40 154 P1 01H 0.05 TEH TEC 29 67 MAI 0.24 105 6

01H

-0.01 0.60 01H 01H 29 67 DSI 0.78 67 P1 02H 0.05 TEH TEC 29 68 DS1 0.19 47 P1 03H 0.08 TEH TEC 29 69 DSI 0.41 45 P1 01H 0.00 TEH TEC 29 84 PCT 0.75 134 0

P1 03C -0.08 TEH TEC 30 13 VOL 0.59 75 3

02C 0.00 02C 02C 30 13 PCT 0.57 0

31 3

02C 0.02 02C 02C 30 14 PCT 1.35 121 22 P1 01C -0.28 TEH TEC 30 15 DSI 0.84 134 P1 01H 0.12 TEH TEC 30 15 PSI 15.23 330 8

07C 0.00 TEH TEC 30 15 CSI 0.19 73 11 07C 0.16 42 07C 07C 30 15 CSI 0.12 65 5

07C 0.00 45 07H 07C 30 15 CSI 0.10 74 5

07C 0.00 46 07C 07H 30 16 PCT 0.67 0

34 3

01C

-0.09 01C 01C 30 16 VOL 0.93 44 3

01C 0.09 01C 01C 30 16 DSI 0.80 39 P1 01H 0.05 TEH TEC 30 19 DSI 0.91 42 P1 01H 0.05 TEH TEC 30 22 DSI 0.74 113 P1 02H 0.22 TEH TEC 30 24 DSI 0.47 84 P1 01H 0.07 TEH TEC 30 24 DSI 1.13 68 P1 03H 0.00 TEH TEC 30 27 DSI 0.77 151 P1 01H 0.12 TEH TEC 30 27 SAI 0.31 102 6

01H 0.01 0.41 01H 01H 30 29 DSI 1.25 59 P1 01H

-0.02 TEH TEC 30 29 DSI 0.55 115 P1 02H 0.22 TEH TEC 30 29 SAI 0.29 104 6

02H

-0.01 0.58 02H 02H

Beaver Valley Unit #1 Page 43 of 54 1 R15 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 30 29 NOI 0.80 110 3

03H 39.72 TEH TEC 30 29 DSI 0.82 167 P1 03H

-0.02 TEH TEC 30 29 SAI 0.35 109 6

03H 0.00 0.42 03H 04H 30 30 DSI 0.41 31 P1 02H

-0.02 TEH TEC 30 32 DSI 0.66 57 P1 02H 0.25 TEH TEC 30 33 DSI 0.72 56 P1 02H 0.05 TEH TEC 30 33 DSI 0.66 55 P1 03H 0.00 TEH TEC 30 33 SAI 0.20 115 6

03H 0.04 0.14 03H 03H 30 34 DSI 0.76 24 P1 02H 0.13 TEH TEC 30 34 SAI 0.18 85 6

02H 0.00 0.29 02H 02H 30 35 DSI 0.73 113 P1 O1H 0.00 TEH TEC 30 35 DSI 0.80 15 P1 02H 0.20 TEH TEC 30 35 SAI 0.26 110 6

02H 0.00 0.32 02H 02H 30 36 DSI 0.74 101 P1 03H

-0.19 2SH TEC 30 36 WAR 0.35 106 2

AV2 0.00 07C 07H 30 37 DSI 0.17 28 P1 01H 0.00 TEH TEC 30 38 DSI 0.33 84 P1 02H 0.13 TEH TEC 30 42 DSI 1.11 49 P1 01H 0.00 TEH TEC 30 42 MAI 0.30 81 6

01H 0.00 0.28 01H 01H 30 45 DSI 1.24 83 P1 02H 0.22 TEH TEC 30 45 DSI 0.81 88 P1 05H 0.35 TEH TEC 30 48 DSI 0.58 77 P1 01H 0.07 TEH TEC 30 51 DSI 0.82 39 P1 02H 0.07 TEH TEC 30 53 PCT 1.06 0

16 P2 AV1 0.00 TEH TEC 30 53 WAR 0.42 129 2

AV1 0.63 07H 07C 30 53 WAR 0.19 138 2

AVI

-0.61 07H 07C 30 53 PCT 1.89 0

24 P2 AV2 0.00 TEH TEC 30 53 WAR 0.22 124 2

AV2

-0.88 07H 07C 30 53 WAR 0.71 117 2

AV2 0.81 07H 07C 30 54 DSI 0.38 140 P1 01H 0.10 TEH TEC 30 54 SAI 0.19 61 6

01H

-0.01 0.31 01H 01H 30 55 DSI 1.01 57 P1 01H 0.02 TEH TEC 30 58 DSI 0.34 66 P1 02H 0.00 TEH TEC 30 61 DSI 0.75 31 P1 01H

-0.05 TEH TEC 30 70 DSI 0.57 49 P1 02H 0.05 TEH TEC 30 74 DSI 0.65 66 P1 01H 0.00 TEH TEC 30 75 DSI 1.09 76 P1 01H 0.12 TEH TEC 30 75 DSI 0.44 52 P1 02H 0.02 TEH TEC 30 77 DSI 0.61 27 P1 02H 0.02 TEH TEC 30 77 DSI 0.67 35 P1 04H 0.05 TEH TEC 30 81 PCT 0.74 130 0

P1 03C

-0.12 TEH TEC 30 81 VOL 0.19 107 6

03C

-0.08 03C 03C 31 20 DSI 1.31 49 P1 01H 0.00 TEH TEC 31 20 MAI 0.37 106 6

01H

-0.01 0.29 01H 01H 31 22 DSI 0.46 87 P1 02H 0.02 TEH TEC 31 26 DSI 0.49 60 P1 02H 0.07 TEH TEC 31 26 DSI 0.69 105 P1 03H 0.15 TEH TEC 31 30 DSI 0.59 46 P1 02H

-0.02 TEH TEC 31 32 DSI 0.42 86 P1 01H 0.12 TEH TEC 31 35 PCT 1.10 0

16 P2 AV2 0.00 TEH TEC 31 35 WAR 0.26 115 2

AV2 0.32 07H 07C

Beaver Valley Unit #1 Page 44 of 54 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 31 35 PCT 1.24 0

18 P2 AV4 0.00 TEH TEC 31 35 WAR 0.26 144 2

AV4

-0.10 07H 07C 31 36 DSI 0.67 79 P1 01H 0.05 TEH TEC 31 38 DSI 0.23 94 P1 01H 0.10 TEH TEC 31 39 DSI 0.87 76 P1 01H 0.00 TEH TEC 31 39 DSI 1.34 78 P1 02H 0.07 TEH TEC 31 40 DSI 0.29 96 P1 01H 0.10 TEH TEC 31 41 DSI 0.70 26 P1 01H 0.05 TEH TEC 31 41 DSI 0.66 61 P1 02H 0.00 TEH TEC 31 42 DSI 1.52 87 P1 01H 0.25 TEH TEC 31 42 DSI 0.78 75 P1 02H 0.05 TEH TEC 31 44 DSI 0.51 98 P1 01H 0.10 TEH TEC 31 48 DSI 0.77 63 P1 01H

-0.02 TEH TEC 31 48 SAI 0.39 94 6

01H

-0.10 0.39 01H 01H 31 50 DSI 0.52 56 P1 01H 0.12 TEH TEC 31 50 MAI 0.22 134 6

01H 0.12 0.27 01H 01H 31 52 DSI 0.46 116 P1 01H 0.10 TEH TEC 31 52 DSI 0.79 64 P1 02H 0.03 TEH TEC 31 54 DSI 0.29 100 P1 01H 0.07 TEH TEC 31 54 DSI 0.23 59 P1 02H 0.00 TEH TEC 31 56 DSI 0.78 40 P1 01H 0.05 TEH TEC 31 59 DSI 0.62 86 P1 01H 0.00 TEH TEC 31 60 DSI 0.83 107 P1 02H

-0.15 TEH TEC 31 60 DSI 0.17 50 P1 03H 0.00 TEH TEC 31 62 DSI 1.82 97 P1 01H 0.00 TEH TEC 31 63 PVN 3.08 31 P2 07H 25.43 07C 07H 31 68 DSI 0.64 73 P1 01H 0.10 TEH TEC 31 68 DSI 1.65 81 P1 02H

-0.05 TEH TEC 31 69 PCT 1.03 25 15 P2 AV1 0.00 TEH TEC 31 69 WAR 0.37 106 2

AV1 0.02 07H 07C 31 71 DSI 0.34 75 P1 01H 0.15 TEH TEC 31 72 DSI 0.88 107 P1 O1H 0.27 TEH TEC 31 74 DSI 0.32 38 P1 011H 0.02 TEH TEC 32 22 DSI 0.68 100 P1 02H 0.02 TEH TEC 32 24 DSI 0.30 51 P1 01H 0.05 TEH TEC 32 24 DSI 0.74 35 P1 02H 0.03 TEH TEC 32 34 DSI 1.11 70 Pi 01 H 0.00 TEH TEC 32 34 SAI 0.51 98 6

01H 0.01 0.36 01H 01H 32 34 DSI 0.45 36 P1 03H 0.00 TEH TEC 32 35 DSI 0.65 44 P1 01H 0.00 TEH TEC 32 38 DSI 0.76 68 P1 01H 0.07 TEH TEC 32 38 DSI 0.60 36 P1 02H 0.03 TEH TEC 32 39 DSI 0.74 164 P1 01H

-0.10 TEH TEC 32 39 SAI 0.23 102 6

01H 0.07 0.42 01H 01H 32 40 DSI 0.79 40 P1 01H 0.00 TEH TEC 32 45 DSI 0.97 72 P1 01H 0.05 TEH TEC 32 46 DSI 0.27 15 P1 02H 0.08 TEH TEC 32 49 DSI 0.49 99 P1 02H 0.17 TEH TEC 32 51 DSI 1.03 114 P1 01H

-0.05 TEH TEC 32 52 DSI 0.44 129 P1 01H 0.07 TEH TEC 32 54 DSI 1.15 85 P1 01H 0.02 TEH TEC

Beaver Valley Unit #1 Page 45 of 54 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inchl Cr-Length Cr-Angle From To 32 60 DSI 0.26 111 P1 01H 0.05 TEH TEC 32 61 DSI 0.40 27 P1 01H 0.00 TEH TEC 32 62 DSI 0.78 148 P1 01H 0.20 TEH TEC 32 62 DSI 0.67 59 P1 02H 0.00 TEH TEC 32 65 DSI 0.32 75 P1 02H

-0.05 TEH TEC 32 70 DSI 0.49 39 P1 02H 0.12 TEH TEC 33 17 PCT 0.67 127 3

P1 03C

-0.12 TEH TEC 33 19 NOI 1.02 118 3

03H 47.50 TEH TEC 33 19 NQI 0.94 116 3

06H 26.30 TEH TEC 33 19 NQI 0.93 116 3

06H 28.37 TEH TEC 33 19 SSA 0.21 119 P2 07H 0.29 06H 07H 33 19 SSA 0.25 122 P2 07H 0.18 06H 07H 33 19 SSA 0.12 121 P2 07H 0.28 07H 07C 33 19 SSA 0.13 131 P2 07H 0.28 07H 07C 33 23 DSI 0.88 30 P1 02H 0.05 TEH TEC 33 25 NOI 0.57 106 3

05H 7.19 TEH TEC 33 25 NOI 0.38 101 3

05H 23.91 TEH TEC 33 27 DSI 0.72 56 P1 01H

-0.07 TEH TEC 33 28 DSI 0.26 115 P1 011H 0.07 TEH TEC 33 31 DSI 1.09 165 P1 02H

-0.05 TEH TEC 33 31 SPR 1.78 57 P1 02H 0.00 TEH TEC 33 31 MAI 0.41 98 6

02H 0.00 0.56 02H 02H 33 33 DSI 1.26 104 P1 01H 0.27 TEH TEC 33 33 DSI 0.81 21 P1 02H 0.07 TEH TEC 33 36 DSI 0.32 86 P1 02H 0.13 TEH TEC 33 37 DSI 0.63 101 P1 01H 0.12 TEH TEC 33 38 NQI 0.49 104 3

01C 44.31 TEH TEC 33 38 NQI 0.54 98 3

01C 37.99 TEH TEC 33 38 DSI 0.77 33 P1 01H 0.00 TEH TEC 33 40 DSI 0.54 79 P1 01H

-0.05 07H TEH 33 40 DSI 0.51 63 P1 02H

-0.05 07H TEH 33 40 DSI 0.55 57 P1 03H

-0.03 07H TEH 33 40 PSI 14.82 340 8

07H 0.00 07H TEH 33 43 DSI 0.76 90 P1 01H

-0.03 07H TEH 33 43 SAI 0.57 100 6

01H 0.00 0.32 01H 01H 33 43 PCT 1.71 0

22 P2 AV1

-0.02 07H TEC 33 43 WAR 0.43 127 2

AV1 0.02 07H 07C 33 43 PCT 0.94 0

14 P2 AV2 0.00 07H TEC 33 43 WAR 0.27 122 2

AV2 0.00 07H 07C 33 43 PCT 2.23 0

27 P2 AV3 0.00 07H TEC 33 43 WAR 0.47 118 2

AV3 0.00 07H 07C 33 43 PCT 1.38 0

19 P2 AV4 0.00 07H TEC 33 43 WAR 0.28 128 2

AV4

-0.15 07H 07C 33 50 DSI 0.49 140 P1 01H 0.00 07H TEH 33 52 PCT 1.38 0

19 P2 AV4 0.00 07H TEC 33 52 WAR 0.41 312 2

AV4

-2.55 07H 07C 33 52 WAR 0.29 342 2

AV4 2.55 07H 07C 33 53 DSI 0.39 69 P1 02H 0.00 07H TEH 33 62 DSI 0.82 86 P1 02H 0.25 TEH TEC 33 62 MAI 0.58 94 6

02H 0.21 0.58 02H 02H 33 62 DSI 0.61 38 P1 03H

-0.02 TEH TEC

Beaver Valley Unit #1 Page 46 of 54 1 R15 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 33 66 DSI 0.75 30 P1 02H 0.07 TEH TEC 33 67 DSI 0.27 133 P1 01H

-0.10 TEH TEC 34 17 VOL 0.93 58 3

01C 0.04 01C 01C 34 17 PCT 0.79 0

37 3

01C -0.04 01C 01C 34 17 PCT 0.28 0

21 3

02C 0.00 02C 02C 34 17 VOL 0.27 69 3

02C 0.04 02C 02C 34 19 PCT 0.56 137 0

P1 02C -0.25 TSH TEC 34 19 PCT 0.54 133 0

P1 02C -0.23 TEH TEC 34 20 DSI 0.78 90 P1 01H 0.08 TEH TEC 34 20 DSI 0.40 88 P1 02H 0.08 TEH TEC 34 26 DSI 0.37 45 P1 01H 0.07 TEH TEC 34 26 DSI 0.88 56 P1 02H 0.12 TEH TEC 34 27 DSI 0.81 59 P1 01H 0.02 TEH TEC 34 27 DSI 0.89 52 P1 02H 0.05 TEH TEC 34 28 DSI 0.52 78 P1 01H 0.05 TEH TEC 34 28 DSI 0.56 83 P1 02H 0.07 TEH TEC 34 28 MAI 0.50 107 6

02H 0.02 0.47 02H 02H 34 29 DSI 0.83 60 P1 01H 0.07 TEH TEC 34 29 DSI 0.83 51 P1 02H 0.00 TEH TEC 34 29 DSI 1.27 21 P1 03H 0.07 TEH TEC 34 29 SPR 1.51 18 P1 03H 0.00 TEH TEC 34 29 SAI 0.29 101 6

03H 0.08 0.32 03H 03H 34 30 DSI 1.09 49 P1 01H

-0.02 TEH TEC 34 30 MAI 0.83 88 6

01H

-0.04 0.43 O1H 01H 34 31 DSI 0.55 106 P1 01H

-0.02 TEH TEC 34 31 DSI 0.61 143 P1 02H 0.10 TEH TEC 34 31 DSI 0.54 8

P1 04H

-0.07 TEH TEC 34 32 DSI 1.50 65 P1 01H 0.15 TEH TEC 34 32 DSI 0.52 77 P1 02H 0.07 TEH TEC 34 33 DSI 1.08 37 P1 01H 0.05 TEH TEC 34 33 MAI 0.41 97 6

01H 0.01 0.34 01H 01H 34 36 DSI 0.60 51 P1 02H 0.05 TEH TEC 34 36 SAI 0.33 101 6

02H

-0.03 0.52 02H 02H 34 38 DSI 0.46 52 P1 01H

-0.02 TEH TEC 34 38 DSI 0.48 49 P1 02H 0.07 TEH TEC 34 40 DSI 0.63 86 P1 02H

-0.08 07H TEH 34 42 DSI 0.36 48 P1 01H

-0.03 07H TEH 34 44 DSI 0.26 91 P1 01H

-0.03 07H TEH 34 46 DSI 0.38 85 P1 02H

-0.05 07H TEH 34 50 DSI 0.71 90 P1 02H

-0.05 07H TEH 34 51 DSI 0.57 65 P1 02H

-0.03 07H TEH 34 53 DSI 0.70 74 P1 02H

-0.08 07H TEH 34 58 DSI 1.58 60 P1 02H

-0.15 TEH TEC 34 61 DSI 0.73 49 P1 01H 0.02 TEH TEC 34 61 DSI 0.91 80 P1 02H 0.07 TEH TEC 34 63 DSI 0.83 95 P1 01H 0.15 TEH TEC 34 63 DSI 0.75 94 P1 02H

-0.17 TEH TEC 34 63 MAI 0.23 91 6

02H

-0.26 0.50 02H 02H 34 64 DSI 0.64 115 P1 01H 0.07 TEH TEC 34 64 DSI 1.18 38 P1 02H 0.00 TEH TEC 34 64 SAI 0.17 122 6

02H 0.00 0.36 02H 02H

Beaver Valley Unit #1 Page 47 of 54 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 34 67 DSI 0.33 61 P1 02H 0.30 TEH TEC 34 67 SAI 0.33 101 6

02H 0.15 0.45 02H 02H 34 70 DSI 0.39 95 P1 01H 0.10 TEH TEC 34 70 MAI 0.36 119 6

01H 0.07 0.36 TSH 01H 34 73 DSI 0.87 37 P1 01H 0.07 TEH TEC 34 79 PCT 0.52 144 0

P1 06C 0.00 TEH TEC 35 17 PCT 1.27 116 20 P1 02C -0.15 TEH TEC 35 17 VOL 1.47 95 6

02C -0.05 02C 02C 35 18 PCT 0.35 0

24 3

02C 0.11 02C 02C 35 18 VOL 0.34 0

3 02C -0.22 02C 02C 35 18 VOL 0.42 57 3

02C 0.18 02C 02C 35 18 PCT 0.34 0

24 3

02C -0.22 02C 02C 35 18 PCT 0.71 144 0

P1 03C -0.13 TEH TEC 35 18 VOL 0.25 105 6

03C -0.06 03C 03C 35 23 DSI 0.47 72 P1 03H

-0.05 TEH TEC 35 24 DSI 0.54 67 P1 01H 0.07 TEH TEC 35 24 DSI 0.50 100 P1 02H

-0.07 TEH TEC 35 24 SPR 1.73 86 P1 02H 0.00 TEH TEC 35 24 MAI 0.23 104 6

02H

-0.13 0.34 02H 02H 35 24 DSI 1.42 43 P1 03H 0.00 TEH TEC 35 24 SAI 0.14 105 6

03H 0.12 0.26 03H 03H 35 26 DSI 0.34 47 P1 01H

-0.02 TEH TEC 35 28 DSI 0.81 84 P1 01H

-0.02 TEH TEC 35 28 DSI 0.42 94 P1 02H 0.02 TEH TEC 35 28 DSI 1.40 72 P1 03H 0.15 TEH TEC 35 28 DSI 0.66 94 P1 04H

-0.22 TEH TEC 35 32 DSI 0.66 27 P1 01H

-0.02 TEH TEC 35 33 DSI 0.79 57 P1 O1H 0.00 TEH TEC 35 35 DSI 1.75 100 P1 01H

-0.05 TEH TEC 35 35 SAI 1.87 71 6

01H

-0.05 0.50 01H 01H 35 35 DSI 2.11 82 P1 02H 0.00 TEH TEC 35 35 MAI 1.05 85 6

02H 0.00 0.39 02H 02H 35 35 DSI 0.28 108 P1 03H 0.05 TEH TEC 35 36 DSI 0.32 76 P1 02H

-0.07 TEH TEC 35 53 DSI 0.34 64 P1 02H 0.03 07H TEH 35 54 DSI 0.37 73 P1 02H 0.00 07H TEH 35 62 DSI 0.51 56 P1 01H 0.02 TEH TEC 35 62 DSI 1.12 43 P1 02H 0.02 TEH TEC 35 62 SPR 1.56 67 P1 02H 0.00 TEH TEC 35 62 MAI 0.35 108 6

02H 0.00 0.32 02H 02H 35 66 DSI 0.32 149 P1 02H 0.13 TEH TEC 35 70 DSI 0.69 93 P1 01H 0.26 TEH TEC 35 70 DSI 1.48 74 P1 02H 0.13 TEH TEC 35 70 DSI 1.14 90 P1 03H 0.08 TEH TEC 35 71 DSI 0.97 86 P1 02H 0.10 TEH TEC 35 71 DSI 0.70 126 P1 03H 0.15 TEH TEC 35 72 DSI 1.19 26 P1 01H 0.00 TEH TEC 35 72 MAI 0.45 80 6

01H

-0.21 0.30 01H 01H 35 72 DSI 1.54 19 P1 03H 0.10 TEH TEC 35 72 MAI 0.29 85 6

03H 0.01 0.41 03H 03H 35 77 PCT 0.80 137 0

P1 01C -0.02 TEH TEC

Beaver Valley Unit #1 Page 48 of 54 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 35 77 PCT 0.92 146 0

P1 02C

-0.22 TEH TEC 35 77 VOL 0.20 138 3

02C

-0.22 02C 02C 35 77 PCT 0.45 153 0

P1 04C

-0.05 TEH TEC 36 20 PCT 0.38 0

25 3

01C

-0.17 01C 01C 36 20 VOL 0.39 74 3

01C 0.18 01C 01C 36 20 PCT 0.11 0

13 3

02C

-0.16 02C 02C 36 20 VOL 0.07 51 3

02C

-0.14 02C 02C 36 22 VOL 0.53 82 3

01C

-0.02 01C 01C 36 22 PCT 0.53 0

30 3

01C -0.03 01C 01C 36 24 DSI 0.80 88 P1 01H 0.05 TEH TEC 36 24 DSI 1.26 50 P1 02H 0.02 TEH TEC 36 24 MAI 0.57 102 6

02H 0.02 0.39 02H 02H 36 24 DSI 0.71 43 P1 03H 0.03 TEH TEC 36 24 DSI 0.30 119 P1 05H 0.03 TEH TEC 36 30 DSI 0.59 40 P1 01H

-0.02 TEH TEC 36 32 DSI 0.51 45 P1 01H 0.05 TEH TEC 36 32 DSI 0.79 38 P1 02H 0.05 TEH TEC 36 33 DSI 0.65 48 P1 01H 0.00 TEH TEC 36 34 DSI 0.39 62 P1 01H 0.00 TEH TEC 36 35 DSI 1.08 88 P1 01H 0.07 TEH TEC 36 36 DSI 0.75 99 P1 O1H 0.10 TEH TEC 36 36 DSI 1.49 122 P1 02H

-0.05 TEH TEC 36 36 DSI 0.63 52 P1 03H 0.03 TEH TEC 36 38 DSI 0.42 56 P1 02H 0.07 TEH TEC 36 39 DSI 0.68 80 P1 02H

-0.15 TEH TEC 36 39 MAI 0.23 81 6

02H

-0.12 0.50 02H 02H 36 39 DSI 1.00 40 P1 03H 0.02 TEH TEC 36 39 SAI 0.31 87 6

03H 0.02 0.23 03H 03H 36 40 DS0 1.17 78 P1 02H

-0.08 07H TEH 36 40 DSI 0.58 46 P1 03H

-0.03 07H TEH 36 41 DSI 0.53 108 P1 02H

-0.08 07H TEH 36 42 DSI 0.34 80 P1 02H 0.05 07H TEH 36 47 DSI 0.62 82 P1 02H

-0.05 07H TEH 36 48 DSI 0.72 76 P1 02H 0.00 07H TEH 36 49 DSI 0.96 40 P1 03H 0.03 07H TEH 36 49 SAI 0.20 73 6

03H 0.03 0.23 03H 03H 36 51 DSI 0.74 75 P1 01H

-0.11 07H TEH 36 51 DSI 0.37 88 P1 02H 0.00 07H TEH 36 52 DSI 0.68 65 P1 01H

-0.03 07H TEH 36 52 SAI 0.15 113 6

01H

-0.02 0.15 01H 01H 36 52 DSI 0.95 75 P1 02H 0.00 07H TEH 36 53 DSI 0.78 63 P1 01H

-0.16 07H TEH 36 53 DSI 0.61 84 P1 02H

-0.11 07H TEH 36 54 DSI 0.59 96 P1 01H

-0.14 07H TEH 36 54 DSI 0.60 67 P1 02H

-0.03 07H TEH 36 58 DSI 0.81 46 P1 02H 0.07 TEH TEC 36 58 WAR 0.33 137 2

AV3 0.00 07H 07C 36 58 PCT 1.16 0

17 P2 AV4 0.00 TEH TEC 36 58 WAR 0.50 122 2

AV4 0.00 07H 07C 36 63 DSI 0.80 110 P1 02H

-0.12 TEH TEC 36 66 DSI 1.45 39 P1 01H 0.00 TEH TEC

Beaver Valley Unit #1 Page 49 of 54 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 36 66 DSI 0.63 77 P1 02H 0.28 TEH TEC 36 68 DSI 1.37 38 P1 02H 0.00 TEH TEC 36 68 SAI 0.30 119 6

02H 0.00 0.34 02H 02H 36 70 DSI 0.88 32 P1 01H 0.02 TEH TEC 36 75 VOL 0.46 58 3

01C -0.13 01C 01C 36 75 PCT 0.42 0

26 3

01C

-0.17 01C 01C 36 77 PCT 0.49 127 7

P1 03C

-0.20 TEH TEC 37 19 PCT 1.13 122 14 P1 02C

-0.22 TEH TEC 37 19 PCT 0.50 131 1

P1 03C -0.05 TEH TEC 37 19 VOL 0.34 110 6

03C 0.09 03C 03C 37 22 DSI 0.67 81 P1 03H 0.10 TEH TEC 37 22 DSI 0.75 91 P1 04H 0.00 TEH TEC 37 22 NOI 0.56 107 3

06C 1.75 TEH TEC 37 22 NQI 0.79 115 3

06H 19.34 TEH TEC 37 22 NQI 0.56 118 3

06H 40.90 TEH TEC 37 26 DSI 0.79 137 P1 01H 0.17 TEH TEC 37 26 DSI 0.81 101 P1 02H

-0.10 TEH TEC 37 30 DSI 0.39 98 P1 01H 0.12 TEH TEC 37 30 DSI 0.78 57 P1 02H 0.12 TEH TEC 37 31 DSI 0.63 67 P1 01H 0.12 TEH TEC 37 31 DSI 0.61 62 P1 02H 0.00 TEH TEC 37 37 DSI 0.75 66 P1 02H 0.05 TEH TEC 37 50 DSI 0.46 61 P1 01H

-0.05 07H TEH 37 51 SCI 0.16 88 P2 TSH 0.26 86 TSH TSH 37 51 SCI 0.17 91 P2 TSH 0.13 71 TSH TSH 37 57 DSI 0.82 48 P1 02H 0.12 TEH TEC 37 63 DSI 1.76 102 P1 02H 0.22 TEH TEC 37 63 DSI 0.99 58 P1 03H

-0.02 TEH TEC 37 67 DSI 1.28 59 P1 02H 0.10 TEH TEC 37 69 DSI 0.31 49 P1 01H 0.00 TEH TEC 37 69 DSI 0.79 66 P1 02H

-0.10 TEH TEC 37 72 DSI 1.44 73 P1 01H 0.12 TEH TEC 37 73 DSI 0.68 49 P1 03H

-0.02 TEH TEC 37 73 SAI 0.25 78 6

03H 0.00 0.32 03H 03H 38 21 PCT 0.18 0

17 3

01C -0.06 01C 01C 38 21 VOL 0.20 53 3

01C 0.02 01C 01C 38 21 VOL 0.33 51 3

02C

-0.01 02C 02C 38 21 PCT 0.26 0

21 3

02C 0.04 02C 02C 38 22 PCT 0.84 132 0

P1 03C -0.07 TEH TEC 38 23 PCT 0.61 134 0

P1 01C 0.02 TEH TEC 38 24 PCT 0.96 130 3

P1 01C -0.23 TEH TEC 38 25 PCT 0.47 117 25 P1 01C -0.07 TEH TEC 38 30 DSI 0.85 61 P1 01H 0.07 TEH TEC 38 35 SVI 0.20 85 6

TSH 0.02 0.34 50 TSH TSH 38 38 DSI 0.86 43 P1 02H 0.05 TEH TEC 38 40 DSI 1.06 68 P1 02H

-0.05 07H TEH 38 50 DSI 0.62 91 P1 01H

-0.08 07H TEH 38 50 DSI 0.84 109 P1 02H

-0.16 07H TEH 38 50 SAI 0.31 102 6

02H

-0.16 0.34 02H 02H 38 51 DSI 0.29 53 P1 02H

-0.11 07H TEH 38 53 DSI 1.85 97 P1 02H

-0.03 07H TEH

Beaver Valley Unit #1.

Page 50 of 54 1 R15 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To

'38 55 DSI 0.44 131 P1 01H 0.02 TEH TEC 38 55 DSI 0.81 92 P1 02H 0.10 TEH TEC 38 55 DSI 0.27 114 P1 03H

-0.05 TEH TEC 38 62 DSI 0.82 28 P1 02H 0.12 TEH TEC 38 65 DSI 0.71 42 P1 02H

-0.02 TEH TEC 38 69 DSI 1.04 32 P1 01H 0.00 TEH TEC 38 69 SAI 0.31 111 6

01H 0.00 0.43 01H 01H 38 69 DSI 1.08 62 P1 02H 0.00 TEH TEC 38 69 DSI 0.33 33 P1 03H 0.05 TEH TEC 38 70 DSI 0.56 50 P1 01H 0.05 TEH TEC 38 70 DSI 0.93 103 P1 02H 0.18 TEH TEC 38 74 DSI 1.53 78 P1 01H 0.07 TEH TEC 38 74 MAI 0.66 107 6

01H

-0.01 0.32 01H 01H 39 23 DSI 0.57 99 P1 03H 0.22 TEH TEC 39 24 PCT 0.98 118 27 P1 01C

-0.27 TEH TEC 39 24 VOL 0.83 101 6

01C

-0.14 01C 01C 39 24 PCT 1.40 120 24 P1 02C

-0.10 TEH TEC 39 26 VOL 0.21 69 3

01C

-0.02 01C 01C 39 26 PCT 0.19 0

18 3

01C 0.01 01C 01C 39 26 VOL 0.20 54 3

02C 0.16 02C 02C 39 26 PCT 0.15 0

16 3

02C

-0.19 02C 02C 39 27 PCT 0.67 137 0

P1 01C

-0.20 TEH TEC 39 27 DSI 0.55 51 P1 02H 0.05 TEH TEC 39 27 PSI 16.20 142 8

07H 0.00 TEH TEC 39 27 CSI 0.28 76 11 07H

-0.03 49 07H 07H 39 27 CSI 0.21 76 5

07H 0.00 50 07H 07C 39 28 DSI 0.55 102 P1 01H 0.17 TEH TEC 39 28 DSI 1.44 75 P1 03H

-0.05 TEH TEC 39 29 CSI 0.13 74 5

07H 0.00 42 07H 07C 39 30 DSI 0.64 55 P1 01H

-0.02 TEH TEC 39 30 SAI 0.26 114 6

01H

-0.02 0.23 01H 01H 39 30 DSI 0.66 60 P1 03H 0.05 TEH TEC 39, 30 DSI 0.58 31 P1 04H 0.03 TEH TEC 39 33 DSI 0.74 93 P1 03H

-0.07 TEH TEC 39 33 DSI 0.48 52 P1 04H 0.07 TEH TEC 39 33 DSI 0.27 82 P1 05H 0.05 TEH TEC 39 35 DSI 0.56 33 P1 03H 0.05 TEH TEC 39 38 DSI 1.02 78 P1 02H 0.02 TEH TEC 39 38 SAI 1.00 85 6

02H 0.02 0.36 02H 02H 39 38 DSI 0.30 118 P1 03H 0.08 TEH TEC 39 39 DSI 1.25 49 P1 02H 0.07 TEH TEC 39 39 MAI 0.40 118 6

02H 0.06 0.41 02H 02H 39 45 DSI 1.62 88 P1 02H 0.29 07H TEH 39 47 DSI 0.42 84 P1 02H

-0.03 07H TEH 39 47 DSI 0.71 48 P1 03H

-0.11 07H TEH 39 50 DSI 0.95 62 P1 02H 0.00 07H TEH 39 51 DSI 0.54 68 P1 01H

-0.13 07H TEH 39 51 DSI 1.54 89 P1 02H

-0.08 07H TEH 39 51 DSI 0.84 33 P1 03H 0.00 07H TEH 39 55 PSI 18.21 123 8

06H 0.00 TEH TEC 39 55 CSI 0.27 75 11 06H 0.01 34 06H 06H

Beaver Valley Unit #1 Page 51 of 54 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inchl Cr-Length Cr-Angle From To 39 57 DSI 0.98 49 P1 02H 0.12 TEH TEC 39 57 SAI 0.24 97 6

02H 0.12 0.38 02H 02H 39 58 DSI 1.04 71 P1 02H 0.05 TEH TEC 39 59 DSI 0.37 89 P1 01H 0.08 TEH TEC 39 59 DSI 0.65 83 P1 02H 0.00 TEH TEC 39 59 MAI 0.34 101 6

02H

-0.09 0.15 02H 02H 39 59 DSI 0.37 19 P1 03H 0.10 TEH TEC 39 73 PCT 0.93 128 0

P1 01C

-0.22 TEH TEC 40 24 PCT 0.77 139 0

P1 01C

-0.25 TEH TEC 40 24 VOL 0.30 107 6

01C -0.15 01C 01C 40 25 PCT 1.10 124 12 P1 01C

-0.03 TEH TEC 40 25 VOL 0.62 98 6

01C 0.05 01C 01C 40 25 PCT 0.75 121 18 P1 02C 0.02 TEH TEC 40 25 PCT 0.57 141 0

P1 03C -0.05 TEH TEC 40 27 PCT 2.09 114 30 P1 02C -0.15 TEH TEC 40 27 VOL 0.87 92 6

02C

-0.11 02C 02C 40 27 PSI 16.21 144 8

07H 0.00 TEH TEC 40 27 PSI 15.35 140 8

07H 0.00 TEH TEC 40 27 CSI 0.27 74 11 07H 0.02 42 07H 07H 40 27 CSI 0.21 71 5

07H 0.00 42 07H 07C 40 53 DSI 0.80 41 P1 02H 0.03 07H TEH 40 54 DSI 0.77 29 P1 02H 0.00 07H TEH 40 56 DSI 0.54 57 P1 02H 0.07 TEH TEC 40 56 PSI 15.38 143 8

06H 0.00 TEH TEC 40 56 CSI 0.27 72 11 06H 0.00 34 06H 06H 40 58 DSI 0.79 34 P1 02H 0.10 TEH TEC 40 65 PCT 0.62 152 0

P1 03C -0.30 TEH TEC 40 69 PCT 0.33 138 0

P1 03C 0.05 TEH TEC 40 71 PCT 0.67 136 0

P1 04C -0.13 07C TEC 40 71 PCT 0.61 132 0

P1 04C -0.16 TEH TEC 41 27 PCT 0.94 139 0

P1 01C -0.03 TEH TEC 41 27 PSI 17.29 140 8

06H 0.00 TEH TEC 41 27 CSI 0.24 78 11 06H 0.02 49 06H 06H 41 27 PSI 18.27 143 8

07H 0.00 TEH TEC 41 27 CSI 0.28 83 11 07H 0.03 42 07H 07H 41 27 CSI 0.21 73 5

07H 0.00 42 07H 07C 41 29 DSI 0.75 55 P1 O1H 0.00 TEH TEC 41 29 PCT 0.96 144 0

P1 02C -0.20 TEH TEC 41 29 PCT 0.50 117 16 P1 03C

-0.02 TEH TEC 41 29 PSI 16.83 141 8

06H 0.00 TEH TEC 41 29 CSI 0.20 80 11 06H 0.01 38 06H 06H 41 30 VOL 0.30 87 3

01C -0.03 01C 01C 41 30 PCT 0.30 0

22 3

01C

-0.01 01C 01C 41 32 PCT 0.64 128 13 P1 02C -0.25 TEH TEC 41 37 PSI 14.93 160 8

07H 0.00 TEH TEC 41 37 CSI 0.14 59 11 07H 0.01 38 07H 07H 41 37 CSI 0.11 65 5

07H 0.00 38 07H 07C 41 39 PSI 18.83 143 8

07H 0.00 TEH TEC 41 39 CSI 0.25 75 11 07H 0.01 38 07H 07H 41 39 CSI 0.23 73 5

07H 0.00 37 07H 07C 41 40 PSI 20.88 149 8

07H 0.00 07H TEH

Beaver Valley Unit #1 Page 52 of 54 1 R15 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 41 40 CSI 0.22 73 11 07H 0.00 45 07H 07H 41 40 CSI 0.13 78 5

07H

-0.07 41 07H 07C 41 41 PSI 14.58 344 8

07H 0.00 07H TEH 41 43 PSI 15.19 180 8

05H 0.41 07H TEH 41 51 DSI 0.50 33 P1 03H

-0.03 07H TEH 41 54 PSI 15.56 161 8

07C 0.00 07H TEC 41 54 PSI 14.82 341 8

07H 0.00 07H TEH 41 55 PSI 16.00 161 8

05C 0.00 TEH TEC 41 58 DSI 0.75 54 P1 03H 0.02 TEH TEC 41 58 DSI 0.57 67 P1 04H 0.05 TEH TEC 41 58 PSI 17.19 122 8

06H

-0.02 TEH TEC 41 58 CSI 0.28 72 11 06H 0.00 38 06H 06H 41 65 PCT 0.89 136 0

P1 01C -0.28 07C TEC 41 65 PCT 0.89 133 0

P1 01C

-0.28 TEH TEC 42 28 PCT 0.38 0

25 3

02C

-0.25 02C 02C 42 28 VOL 0.39 99 3

02C 0.24 02C 02C 42 28 DSI 0.37 28 P1 05H 0.05 TEH TEC 42 28 DNT 4.06 179 P1 AV3 0.15 TEH TEC 42 28 SAI 0.34 25 2

AV3

-0.13 0.67 07H 07C 42 32 VOL 0.71 80 3

02C 0.10 02C 02C 42 32 PCT 0.70 0

35 3

02C 0.09 02C 02C 42 32 PCT 0.53 124 20 P1 03C -0.20 TEH TEC 42 33 PCT 0.54 127 9

P1 02C 0.05 TEH TEC 42 33 VOL 0.65 91 6

02C -0.09 02C 02C 42 34 PCT 0.33 0

23 3

01C 0.01 01C 01C 42 34 VOL 0.34 244 3

01C

-0.01 01C 01C 42 34 PCT 1.19 45 16 P2 AV3 0.31 TEH TEC 42 35 PCT 0.47 126 11 P1 01C

-0.17 TEH TEC 42 38 PSI 16.48 142 8

06H 0.00 TEH TEC 42 38 CSI 0.19 62 11 06H

-0.01 45 06H 06H 42 40 DSI 0.59 35 P1 03H

-0.03 07H TEH 42 40 PSI 25.53 123 8

07H 0.00 07H TEH 42 40 CSI 0.24 64 11 07H 0.00 38 07H 07H 42 40 CSI 0.17 75 5

07H 0.00 56 07H 07C 42 53 DSI 0.28 119 P1 01H

-0.11 07H TEH 42 54 PSI 16.80 159 8

06H 0.00 07H TEH 42 54 CSI 0.19 66 11 06H

-0.04 42 06H 06H 42 55 PSI 15.84 163 8

07C 0.00 TEH TEC 42 57 PCT 0.66 139 0

P1 01C -0.20 TEH TEC 42 64 DSI 0.24 68 P1 03H 0.00 TEH TEC 42 64 SAI 0.18 120 6

03H 0.08 0.48 03H 03H 42 67 PCT 1.19 122 5

P1 03C -0.17 TEH TEC 42 67 VOL 0.54 105 3

03C -0.17 03C 03C 43 30 PCT 0.52 0

30 3

01C 0.15 01C 01C 43 30 VOL 0.56 69 3

01C -0.33 01C 01C 43 30 PCT 0.63 0

33 3

02C -0.16 02C 02C 43 30 VOL 0.81 50 3

02C 0.02 02C 02C 43 30 PCT 1.07 130 10 P1 03C -0.18 TEH TEC 43 30 VOL 0.51 98 6

03C

-0.09 03C 03C 43 30 DSI 0.84 72 P1 04H 0.18 TEH TEC 43 31 PCT 0.28 0

21 3

02C -0.08 02C 02C

Beaver Valley Unit #1 Page 53 of 54 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 43 31 VOL 0.24 97 3

02C 0.11 02C 02C 43 31 PCT 1.36 134 0

P1 03C -0.22 TEH TEC 43 33 PCT 1.39 123 16 P1 02C -0.20 TEH TEC 43 33 VOL 1.00 90 6

02C -0.19 02C 02C 43 34 PCT 1.15 124 0

P1 01C 0.08 TEH TEC 43 34 VOL 0.74 99 6

01C 0.13 01C 01C 43 34 PCT 0.61 129 0

P1 03C -0.05 TEH TEC 43 39 PCT 0.25 125 5

P1 01C -0.05 TEH TEC 43 39 PCT 0.66 124 7

P1 02C 0.17 TEH TEC 43 39 VOL 0.28 93 6

02C 0.27 02C 02C 43 45 PCT 0.58 149 0

P1 02C -0.08 07H TEC 43 47 DSI 0.25 138 P1 02H 0.00 07H TEH 43 54 DSI 0.62 83 P1 02H

-0.05 07H TEH 43 57 DSI 0.58 32 P1 02H

-0.02 TEH TEC 43 59 PCT 0.58 139 0

P1 03C -0.17 TEH TEC 43 64 PCT 0.42 127 1

P1 05C -0.12 TEH TEC 44 33 PCT 2.19 108 40 P1 01C -0.05 TEH TEC 44 33 VOL 1.03 80 6

01C 0.06 01C 01C 44 33 PCT 0.31 134 0

P1 02C 0.00 TEH TEC 44 33 PCT 1.19 127 9

P1 03C -0.17 TEH TEC 44 33 VOL 0.53 89 6

03C -0.13 03C 03C 44 37 PCT 1.17 131 0

P1 02C -0.10 TEH TEC 44 37 VOL 0.65 101 6

02C -0.08 02C 02C 44 37 PCT 0.97 118 7

P1 03C

-0.23 TEH TEC 44 38 PCT 1.39 115 15 P1 01C

-0.15 TEH TEC 44 38 CSI 0.58 167 3

07H

-0.24 51 07H 07C 44 40 PCT 0.56 138 0

P1 02C -0.20 07H TEC 44 40 PCT 0.69 139 0

P1 03C -0.30 07H TEC 44 40 DSI 0.31 37 P1 05H

-0.11 07H TEH 44 45 PCT 0.37 135 0

P1 01C 0.15 07H TEC 44 50 PCT 0.80 133 0

P1 06C 0.16 07H TEC 44 53 PCT 0.74 112 25 P1 01C

-0.29 07H TEC 44 53 DSI 0.40 77 P1 04H

-0.11 07H TEH 44 53 PSI 16.33 165 8

06H 0.00 07H TEH 44 57 CSI 0.18 74 11 06H

-0.03 33 06H 06H 44 59 PCT 0.72 110 30 P1 03C 0.13 TEH TEC 44 59 VOL 0.23 143 3

03C 0.13 03C 03C 45 37 PCT 0.74 141 0

P1 02C -0.25 TEH TEC 45 37 DSI 0.94 127 P1 02H 0.27 TEH TEC 45 41 PCT 0.96 129 0

P1 02C

-0.15 07H TEC 45 41 PCT 0.95 127 0

P1 02C

-0.18 07H TEC 45 41 VOL 0.20 118 6

02C 0.02 02C 02C 45 41 PCT 0.30 127 0

P1 03C

-0.28 07H TEC 45 41 PCT 0.29 127 0

P1 03C

-0.18 07H TEC 45 41 VOL 0.18 79 6

03C -0.20 03C 03C 45 41 PSI 22.61 125 8

07H 0.00 07H TEH 45 41 CSI 0.17 96 11 07H 0.00 42 07H 07H 45 41 PCT 1.62 0

21 P2 AV1 0.00 07H TEC 45 41 PCT 1.68 0

22 P2 AV1 0.15 07H TEC 45 41 WAR 0.26 113 2

AV1

-0.01 07H 07C 45 42 PSI 21.30 305 8

07H 0.00 07H TEH

Beaver Valley Unit #1 Page 54 of 54 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 45 42 CSI 0.23 67 11 07H 0.00 42 07H 07H 45 44 PCT 0.87 132 0

P1 01C 0.21 07H TEC 45 45 PCT 0.12 135 14 3

01C 0.00 01C 01C 45 45 VOL 0.11 90 3

01C -0.03 01C 01C 45 45 PCT 0.51 77 30 3

02C

-0.09 02C 02C 45 45 VOL 0.75 63 6

02C 0.01 02C 02C 45 48 PCT 0.42 129 0

P1 03C -0.03 07H TEC 45 50 PCT 0.44 118 14 P1 01C 0.13 07H TEC 45 50 PCT 0.75 135 0

P1 02C

-0.23 07H TEC 45 52 PCT 0.94 134 0

P1 03C 0.10 07H TEC 45 52 DSI 0.61 128 P1 03H 0.11 07H TEH 45 53 PCT 0.74 140 0

P1 01C -0.18 07H TEC 45 53 PSI 17.40 144 8

06H 0.00 07H TEH 45 53 CSI 0.32 77 11 06H 0.01 45 06H 06H 45 54 DSI 0.51 133 P1 06H 0.00 07H TEH 46 41 PCT 0.67 111 36 P1 02C -0.17 07H TEC 46 41 PCT 0.68 105 37 P1 02C

-0.18 07H TEC 46 41 PSI 16.80 153 8

04C 0.00 07H TEC 46 41 CSI 0.23 66 11 04C 0.00 38 04C 04C 46 41 PSI 16.04 139 8

05C 0.00 07H TEC 46 41 CSI 0.31 68 11 05C -0.13 38 05C 05C 46 41 PSI 23.04 128 8

07H 0.00 07H TEH 46 41 CSI 0.29 82 11 07H 0.00 57 07H 07H 46 42 PCT 3.64 113 33 P1 02C -0.22 07H TEC 46 42 PCT 3.65 110 29 P1 02C -0.15 07H TEC 46 42 PSI 23.14 128 8

07H 0.00 07H TEH 46 42 CSI 0.21 70 11 07H 0.00 53 07H 07H 46 45 DSI 0.81 32 P1 03H 0.05 07H TEH 46 50 PCT 0.64 113 24 P1 03C -0.28 07H TEC 46 54 PSI 15.26 160 8

02C 0.00 07H TEC

ATTACHMENT IA BEAVER VALLEY UNIT #1 1R15 S/G EXAMINATION RESULTS IRC-E-lA TUBES REMOVED FROM SERVICE

Beaver Valley Unit #1 1 R1 5 S/G Examination Results 1 RC-E-1 A (TUBES REMOVED FROM SERVICE)

Page 1 of 3 Row Col 1

24 1

30 1

45 2

23 2

61 3

10 3

75 3

78 4

73 4

74 5

44 6

5 6

70 6

70 6

73 6

75 6

86 6

94 7

80 7

80 8

27 8

39 8

41 8

76 9

36 9

38 9

73 9

74 9

83 9

86 9

86 10 32 10 66 10 66 11 40 11 77 11 77 12 32 12 35 12 50 12 69 12 93 13 37 13 41 13 47 14 26 14 46 14 48 14 72 15 23 15 35 Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To SCI 2.56 21 P2 07H 9.51 45 07C 07H SAI 0.18 113 6

02H 0.09 0.34 02H 02H ADMINISTRATIVELY PLUGGED SAI 0.11 78 6

TSH 0.40 0.24 TSH TSH SAI 1.04 9

6 TSH

-1.68 0.19 TSH TSH SCI 0.16 56 P2 TSH

-0.10 52 TSH TSH SAI 1.34 87 2

05H 0.08 0.71 05H 05H MAI 2.03 93 2

02H 0.24 0.45 02H 02H SAI 0.15 107 6

TSH

-0.26 0.17 TSH TSH PVN 2.00 64 2

07H 4.87 07H 07H MAI 0.61 86 6

011H

-0.15 0.73 01H 01H SCI 0.27 107 P2 TSH 0.06 82 TSH TSH SAI 0.50 86 6

03H

-0.22 0.24 03H 03H SAI 0.21 131 6

06H 0.04 0.28 06H 06H SAI 0.14 72 6

TSH

-0.07 0.14 TSH TSH SAI 0.36 65 6

TSH

-0.03 0.19 TSH TSH SAI 0.17 109 6

01H 0.14 0.21 01H 01H SVI 0.19 117 6

01H 0.15 0.29 121 01H 01H DSI 2.07 71 P1 011H

-0.05 TEH TEC MAI 0.35 104 6

01H

-0.09 0.39 01H 01H NQI 0.12 126 P1 TSH 1.34 TEH TEC SAI 0.35 114 6

TSH 0.58 0.52 TSH TSH MAI 0.67 115 2

02H 0.20 0.62 02H 02H SAI 0.40 70 6

02H 0.07 0.72 02H 02H MAI 0.39 95 2

02H

-0.11 0.71 02H 02H SAI 0.96 100 2

02H

-0.05 0.51 02H 02H SAI 0.17 131 6

TSH 0.00 0.15 TSH TSH SAI 0.78 88 2

02H 0.22 0.24 02H 02H SAI 0.26 91 6

04H

-0.06 0.50 04H 04H DSI 2.08 111 P1 04H 0.02 TEH TEC MAI 0.62 95 6

04H

-0.11 0.41 04H 04H SAI 0.34 125 1

02H 0.01 0.40 02H 02H DSI 2.23 91 P1 01H 0.05 TEH TEC MAI 2.74 34 6

01H

-0.02 0.50 01H 01H PTP 0.78 91 6

STH 1.20 STH STH DSI 4.57 60 P1 01H 0.05 TEH TEC MAI 2.36 65 6

01H

-0.04 0.54 01H 01H SAI 0.60 96 2

011H 0.17 0.36 01H 01H SAI 0.86 100 2

02H

-0.26 0.27 02H 02H MAI 0.18 92 6

TSH 0.59 0.39 TSH TSH PTP 0.94 95 6

STH 1.20 STH STH SVI 0.19 66 6

02H 0.19 0.23 80 02H 02H PTP 0.77 76 6

STH 1.55 STH STH PTP 0.65 75 6

STH 1.17 STH STH SAI 0.24 58 2

04H

-0.08 0.24 04H 04H SAI 0.14 79 6

TSH 0.10 0.39 TSH TSH MAI 1.14 98 2

01H

-0.02 0.72 01H 01H MAI 1.24 90 2

01H 0.01 0.42 01KH 011H PTP 0.93 56 6

STH 1.76 STH STH SAI 1.06 100 2

02H 0.11 0.52 02H 02H MAI 0.69 104 2

02H 0.08 0.65 02H 02H

Beaver Valley Unit #1 1 R15 S/G Examination Results 1 RC-E-1 A (TUBES REMOVED FROM SERVICE)

Page 2 of 3 Row Col 15 40 15 41 15 42 15 42 16 23 16 28 16 41 16 56 17 19 17 19 17 31 17 56 18 19 18 30 18 36 18 43 18 78 18 78 18 78 19 26 19 35 19 37 20 11 20 21 20 26 20 28 20 36 20 36 20 36 21 21 21 33 21 33 21 53 21 53 21 55 21 68 22 68 23 7

23 10 23 36 24 72 24 79 24 79 25 36 25 78 25 79 25 82 28 21 29 26 29 32 29 32 Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To SAI 0.46 75 6

TSH 0.66 0.36 TSH TSH PTP 0.33 82 6

STH 1.16 STH STH SAI 1.43 110 2

02H 0.00 0.58 02H 02H PTP 0.83 77 6

STH 1.17 STH STH MAI 0.49 82 6

01H -0.13 0.23 01H 01H SAI 0.18 105 6

TSH 0.16 0.23 TSH TSH PTP 0.50 54 6

STH 1.16 STH STH SAI 0.15 88 6

02H 0.00 0.16 02H 02H DSI 2.03 18 P1 02H

-0.16 TEH TEC SAI 0.47 98 6

02H 0.01 0.43 02H 02H SAI 0.65 101 2

01H -0.06 0.54 01H 01H SAI 0.79 15 6

TSH

-0.18 0.20 TSH TSH SAI 0.21 107 6

03H 0.01 0.43 03H 03H SAI 0.58 118 2

03H

-0.18 0.37 03H 03H SAI 1.78 103 2

01H

-0.04 0.49 01H 01H SAI 0.18 111 6

TSH 0.28 0.30 TSH TSH DNT 3.03 187 P1 01H 0.30 TEH TEC MAI 0.70 98 6

01H -0.10 0.35 01H 01H MAI 0.50 86 6

02H

-0.08 0.32 02H 02H SAI 0.43 69 6

TSH 0.07 0.31 TSH TSH MAI 0.70 98 2

03H 0.18 0.68 03H 03H PTP 0.89 57 6

STH 0.55 STH STH SCI 0.27 28 P2 TSH

-0.03 110 TSH TSH MAI 0.61 97 6

02H 0.13 0.45 02H 02H SAI 0.37 99 6

01H -0.02 0.21 01H 01H MAI 0.32 127 6

TSH

-0.07 0.39 TSH TSH DSI 2.37 33 P1 01H 0.02 TEH TEC SAI 1.00 55 6

01H 0.00 0.50 01H 01H SAI 2.19 32 6

TSH

-0.43 0.26 TSH TSH SAI 0.18 91 6

02H 0.00 0.50 02H 02H DSI 2.17 48 P1 01H 0.00 TEH TEC MAI 0.31 89 6

01H -0.18 0.63 01H 01H DNT 9.36 180 P1 03H 0.00 TEH TEC MAI 0.21 67 6

03H 0.20 0.13 03H 03H SAI 0.33 85 6

02H 0.12 0.21 02H 02H MAI 0.27 85 6

03H 0.03 0.53 03H 03H SAI 1.15 103 2

02H 0.07 0.64 02H 02H SAI 0.19 110 6

02H 0.00 0.36 02H 02H SAI 0.44 96 6

01H 0.12 0.48 01H 01H SAI 0.40 141 6

TSH

-0.05 0.29 TSH TSH SAI 1.42 90 2

04H 0.25 0.26 04H 04H DSI 2.10 52 P1 02H 0.15 TEH TEC MAI 0.56 91 6

02H

-0.07 0.39 02H 02H SAI 0.15 107 6

TSH

-0.24 0.29 TSH TSH SCI 0.16 65 P2 TSH

-0.20 93 TSH TSH MAI 0.61 94 6

01H 0.06 0.34 01H 01H SCI 0.40 76 P2 TSH

-0.14 165 TSH TSH SAI 0.36 96 6

03H

-0.16 0.25 03H 03H SVI 0.46 102 6

01H

-0.06 0.64 60 01H 01H DNT 2.91 184 P1 02H

-0.1 TEH TEC SAI 0.17 94 6

02H 0.10 0.24 02H 02H

Beaver Valley Unit #1 Page3 of 3 1 R15 S/G Examination Results 1 RC-E-1 A (TUBES REMOVED FROM SERVICE)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 29 60 PCT 5.45 0

42 P2 AV3 0.00 07H TEC 31 63 PVN 3.08 31 P2 07H 25.43 07C 07H 33 19 NOI 1.02 118 3

03H 47.50 TEH TEC 33 19 NQI 0.94 116 3

06H 26.30 TEH TEC 33 19 NQI 0.93 116 3

06H 28.37 TEH TEC 33 19 SSA 0.21 119 P2 07H 0.29 06H 07H 33 19 SSA 0.25 122 P2 07H 0.18 06H 07H 33 19 SSA 0.12 121 P2 07H 0.28 07H 07C 33 19 SSA 0.13 131 P2 07H 0.28 07H 07C 33 31 MAI 0.41 98 6

02H 0.00 0.56 02H 02H 34 29 SAI 0.29 101 6

03H 0.08 0.32 03H 03H 35 24 MAI 0.23 104 6

02H

-0.13 0.34 02H 02H 35 35 DSI 2.11 82 P1 02H 0.00 TEH TEC 35 35 MAI 1.05 85 6

02H 0.00 0.39 02H 02H 35 62 MAI 0.35 108 6

02H 0.00 0.32 02H 02H 37 51 SCI 0.16 88 P2 TSH 0.26 86 TSH TSH 37 51 SCI 0.17 91 P2 TSH 0.13 71 TSH TSH 38 35 SVI 0.20 85 6

TSH 0.02 0.34 50 TSH TSH 42 28 DNT 4.06 179 P1 AV3 0.15 TEH TEC 42 28 SAI 0.34 25 2

AV3

-0.13 0.67 07C 07H 44 33 PCT 2.19 108 40 P1 01C -0.05 07C TEC

ATTACHMENT 2 BEAVER VALLEY UNIT #1 IR15 S/G EXAMINATION RESULTS IRC-E-IB TUBES WITH INDICATIONS

Beaver Valley Unit #1 1 R1 5 S/G Examination Results 1RC-E-1B (TUBES WITH INDICATIONS)

Page 1 of 41 Row Col 1

4 1

4 1

5 1

6 1

6 1

10 1

10 1

10 1

13 1

13 1

13 1

14 1

14 1

14 1

14 1

14 1

17 1

27 1

29 1

33 1

33 1

34 1

48 1

49 1

54 1

55 1

55 1

60 1

62 1

66 1

68 1

68 1

70 1

70 1

92 2

5 2

5 2

7 2

7 2

9 2

9 2

9 2

9 2

9 2

9 2

11 2

11 2

12 2

12 2

12 2

13 Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To DSI 0.70 106 P1 01H 0.00 07H TEH DSI 0.87 77 P1 02H 0.03 07H TEH DSI 0.99 79 P1 01H 0.03 07H TEH DSI 0.36 122 P1 01H

-0.06 07H TEH DSI 0.57 35 P1 02H 0.00 07H TEH DSI 0.71 47 P1 01H 0.03 07H TEH MAI 0.48 99 6

01H 0.01 0.45 01H 01H DSI 0.16 78 P1 06H

-0.03 07H TEH DSI 0.85 81 P1 01H

-0.09 07H TEH MAI 0.29 104 6

01H 0.04 0.45 01H 01H DSI 1.22 95 P1 02H

-0.11 07H TEH DSI 0.92 90 P1 01H

-0.18 07H TEH SAI 0.25 115 6

01H

-0.15 0.22 01H 01H DSI 1.38 83 P1 02H

-0.11 07H TEH DSI 0.30 98 P1 04H

-0.03 07H TEH DSI 0.51 43 P1 05H 0.06 07H TEH DSI 0.87 94 P1 02H

-0.14 07H TEH DSI 1.06 105 P1 01H

-0.15 07H TEH DSI 0.56 53 P1 01H

-0.06 07H TEH DSI 0.52 83 P1 01H

-0.11 07H TEH DSI 0.62 68 P1 02H

-0.08 07H TEH DSI 0.50 95 P1 02H

-0.14 07H TEH DSI 0.88 89 P1 01H 0.03 07H TEH DSI 1.17 70 P1 02H 0.00 07H TEH DSI 0.33 57 P1 01H

-0.03 07H TEH DSI 0.49 37 P1 02H 0.00 07H TEH DS0 0.22 102 P1 03H 0.12 07H TEH DSI 0.49 61 P1 01H

-0.02 07H TEH DSI 0.54 117 P1 01H 0.05 07H TEH DSI 0.71 60 P1 02H

-0.07 07H TEH DSI 0.94 74 P1 02H

-0.10 07H TEH DSI 0.75 62 P1 03H

-0.02 07H TEH DSI 0.79 61 P1 02H 0.00 07H TEH DSI 0.26 110 P1 05H

-0.05 07H TEH DSI 0.61 17 P1 02H 0.02 07H TEH DSI 0.50 38 P1 01H

-0.12 07H TEH DSI 0.93 45 P1 02H

-0.06 07H TEH DSI 0.89 55 P1 01H 0.00 07H TEH DSI 1.07 52 P1 02H 0.00 07H TEH DSI 0.99 89 P1 01H -0.18 07H TEH DSI 1.37 73 P1 02H

-0.06 07H TEH DSI 0.38 72 P1 03H

-0.11 07H TEH DSI 1.22 44 P1 04H

-0.06 07H TEH MAI 0.37 94 6

04H

-0.08 0.37 04H 04H DSI 0.56 60 P1 05H

-0.06 07H TEH DSI 0.80 71 P1 01H

-0.12 07H TEH DSI 1.32 76 P1 02H

-0.14 07H TEH DSI 1.43 70 P1 01H

-0.03 07H TEH DSI 0.46 128 P1 02H

-0.12 07H TEH DSI 0.63 111 P1 03H

-0.14 07H TEH DSI 0.93 72 P1 01H

-0.18 07H TEH

Beaver Valley Unit #1 Page 2 of 41 1 R1 5 S/G Examination Results 1RC-E-1B (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 2

13 DSI 0.36 38 P1 02H

-0.03 07H TEH 2

13 DSI 0.63 60 P1 03H 0.06 07H TEH 2

15 NOI 1.02 127 3

06C 47.40 07C TEC 2

17 DSI 0.75 96 P1 01H 0.00 07H TEH 2

19 DSI 2.00 97 P1 01H

-0.15 07H TEH 2

19 MAI 1.00 85 6

01H

-0.12 0.42 01H 01H 2

24 DSI 0.61 77 P1 01H 0.00 07H TEH 2

24 DSI 0.76 92 P1 02H

-0.09 07H TEH 2

24 DSI 0.40 163 P1 03H

-0.12 07H TEH 2

25 DSI 1.62 100 P1 01H

-0.17 07H TEH 2

26 DSI 0.51 80 P1 01H

-0.06 07H TEH 2

28 DSI 1.13 20 P1 01H

-0.03 07H TEH 2

28 SAI 0.15 78 6

01H

-0.22 0.17 01H 01H 2

28 DSI 0.74 64 P1 02H

-0.03 07H TEH 2

30 DSI 1.36 119 P1 01H

-0.17 07H TEH 2

30 DSI 0.63 76 P1 02H

-0.08 07H TEH 2

30 DSI 0.59 34 P1 03H 0.00 07H TEH 2

31 DSI 0.84 86 P1 01H

-0.09 07H TEH 2

31 DSI 1.11 110 P1 02H

-0.14 07H TEH 2

32 DSI 0.36 131 P1 01H

-0.17 07H TEH 2

32 SAI 0.24 102 6

01H

-0.07 0.30 TSH 01H 2

32 NOI 0.31 111 3

TSH 35.76 07H TEH 2

33 DSI 0.47 86 P1 02H 0.09 07H TEH 2

33 DSI 0.57 92 P1 03H

-0.06 07H TEH 2

35 DSI 0.87 95 P1 02H 0.00 07H TEH 2

36 DSI 0.58 76 P1 02H

-0.08 07H TEH 2

39 DSI 0.88 113 P1 01H

-0.14 07H TEH 2

40 DSI 1.30 89 P1 01H

-0.12 07H TEH 2

41 DSI 0.68 123 P1 01H

-0.06 07H TEH 2

41 SAI 0.54 96 6

01H

-0.06 0.31 01H 01H 2

43 DSI 0.40 128 P1 011H 0.00 07H TEH 2

46 DSI 1.14 71 P1 01H

-0.03 07H TEH 2

47 DSI 0.40 91 P1 02H 0.03 07H TEH 2

49 DSI 0.96 81 P1 011H 0.17 07H TEH 2

49 DSI 0.33 91 P1 02H

-0.14 07H TEH 2

52 DSI 0.86 41 P1 01H

-0.06 07H TEH 2

52 SAI 0.36 93 6

01 H

-0.02 0.47 01H 01H 2

52 DSI 0.22 98 P1 03H 0.00 07H TEH 2

57 DSI 0.33 58 P1 01H 0.00 07H TEH 2

60 DSI 1.06 71 P1 011H 0.00 07H TEH 2

65 DSI 0.55 57 P1 02H 0.00 07H TEH 2

66 DSI 0.42 78 P1 02H

-0.02 07H TEH 2

69 DSI 1.28 80 P1 02H

-0.10 07H TEH 2

69 DSI 1.34 50 P1 03H

-0.07 07H TEH 2

69 MAI 0.41 100 6

03H

-0.13 0.35 03H 03H 2

72 DSI 0.42 100 P1 01H

-0.02 07H TEH 2

72 DSI 0.64 49 P1 02H 0.05 07H TEH 2

72 SAI 0.19 103 6

02H 0.00 0.29 02H 02H 2

72 DSI 1.03 48 P1 03H

-0.02 07H TEH 2

72 MAI 0.33 105 6

03H

-0.10 0.36 03H 03H 2

73 DSI 0.73 57 P1 01H 0.00 07H TEH

Beaver Valley Unit #1 1 R1 5 S/G Examination Results 1RC-E-1B (TUBES WITH INDICATIONS)

Page 3 of 41 Row Col 2

73 2

74 2

74 2

74 2

74 2

79 2

79 2

79 2

81 2

83 2

85 2

85 2

85 2

85 2

86 2

86 2

88 2

88 2

90 2

90 2

93 2

93 2

94 2

94 3

1 3

1 3

5 3

6 3

6 3

6 3

6 3

8 3

8 3

8 3

8 3

8 3

8 3

8 3

9 3

9 3

9 3

16 3

16 3

18 3

18 3

27 3

27 3

27 3

27 3

27 3

31 Ind Volts Phase %TW Chan Loc Inchl Cr-Length Cr-Angle From To DSI 0.94 54 P1 02H 0.00 07H TEH DSI 0.97 146 P1 01H 0.17 07H TEH DSI 0.88 57 P1 02H 0.00 07H TEH MAI 0.41 96 6

02H 0.02 0.29 02H 02H DSI 0.49 62 P1 03H

-0.10 07H TEH DSI 0.85 56 P1 02H 0.02 07H TEH DSI 0.72 95 P1 04H

-0.07 07H TEH SAI 0.31 106 6

04H

-0.05 0.36 04H 04H DSI 0.67 63 P1 02H

-0.07 07H TEH DSI 0.76 62 P1 03H 0.00 07H TEH DSI 0.50 57 P1 02H 0.05 07H TEH DSI 0.38 85 P1 03H

-0.02 07H TEH DSI 0.89 44 P1 04H

-0.02 07H TEH SAI 0.30 101 6

04H 0.01 0.33 04H 04H DSI 0.78 62 P1 03H 0.00 07H TEH DSI 1.18 84 P1 04H 0.00 07H TEH DSI 0.67 94 P1 02H

-0.10 07H TEH DSI 0.50 30 P1 04H 0.05 07H TEH DSI 0.63 131 P1 04H 0.05 07H TEH DSI 0.49 59 P1 05H 0.02 07H TEH DSI 0.63 40 P1 02H 0.00 07H TEH SAI 0.14 108 6

02H 0.11 0.14 02H 02H PCT 0.95 136 0

P1 01C 0.15 07C TEC DSI 0.36 100 P1 04H 0.00 07H TEH DSI 0.76 64 P1 01H

-0.03 07H TEH MAI 0.32 122 6

01H 0.00 0.37 01H 01H DSI 0.37 80 P1 02H 0.00 07H TEH DSI 0.34 77 P1 01H

-0.12 07H TEH DSI 0.70 40 P1 02H

-0.09 07H TEH SAI 0.13 126 6

02H

-0.14 0.25 02H 02H DSI 0.43 73 P1 05H

-0.03 07H TEH DSI 1.32 47 P1 01H

-0.03 07H TEH MAI 0.29 101 6

01H

-0.03 0.37 01H 01H DSI 1.32 74 P1 02H

-0.09 07H TEH DSI 0.93 66 P1 03H

-0.17 07H TEH DSI 0.60 71 P1 04H

-0.03 07H TEH SAI 0.25 105 6

04H 0.18 0.26 04H 04H DSI 0.37 85 P1 05H

-0.03 07H TEH DSI 0.82 68 P1 01H

-0.06 07H TEH MAI 0.28 106 6

01H

-0.03 0.37 01H 01H DSI 0.45 85 P1 02H

-0.06 07H TEH DSI 1.59 85 P1 01H

-0.09 07H TEH DSI 1.53 86 P1 02H

-0.14 07H TEH DSI 1.06 56 P1 01H

-0.03 07H TEH DSI 0.87 73 P1 02H

-0.20 07H TEH DSI 1.25 90 P1 01H

-0.12 07H TEH DSI 0.48 103 P1 02H

-0.06 07H TEH DSI 0.48 93 P1 03H

-0.06 07H TEH DSI 0.31 51 P1 04H

-0.06 07H TEH DSI 0.14 104 P1 05H 0.03 07H TEH DSI 0.73 28 P1 01H

-0.09 07H TEH

Beaver Valley Unit #1 Page 4 of 41 1 R1 5 S/G Examination Results 1 RC-E-1 B (TUBES WITH INDICATIONS)

Row Cot Ind Volts Phase %TW Chan Loc Inchl Cr-Length Cr-Angle From To 3

31 MAI 0.40 82 6

01H 0.07 0.37 01H 01H 3

32 DSI 0.44 110 P1 02H

-0.06 07H TEH 3

35 DSI 0.44 44 P1 01H 0.00 07H TEH 3

35 DSI 0.39 112 P1 02H

-0.14 07H TEH 3

43 DSI 0.63 49 P1 01H 0.00 07H TEH 3

43 SAI 0.24 94 6

01H

-0.08 0.31 01H 01H 3

49 DSI 0.88 69 P1 01H 0.15 07H TEH 3

49 DSI 1.07 88 P1 02H

-0.12 07H TEH 3

53 DSI 0.64 122 P1 01H 0.15 07H TEH 3

53 DSI 0.37 81 P1 04H 0.06 07H TEH 3

55 DSI 0.80 124 P1 01H

-0.09 07H TEH 3

58 DSI 0.74 59 P1 01H 0.00 07H TEH 3

61 DSI 0.76 130 P1 03H 0.20 07H TEH 3

61 SAI 0.40 90 6

03H 0.25 0.19 03H 03H 3

61 SAI 0.46 92 6

03H

-0.20 0.19 03H 03H 3

61 DSI 0.74 131 P1 06H 0.23 07H TEH 3

61 SAI 0.37 71 6

06H 0.28 0.17 06H 06H 3

62 DSI 0.64 22 P1 01H

-0.02 07H TEH 3

63 DSI 0.64 64 P1 03H 0.02 07H TEH 3

64 DSI 1.16 69 P1 03H

-0.05 07H TEH 3

64 SAI 0.33 110 6

03H 0.01 0.26 03H 03H 3

65 DSI 1.46 28 P1 02H 0.12 07H TEH 3

65 MAI 0.23 123 6

02H

-0.10 0.31 02H 02H 3

65 SPR 1.82 211 P1 03H 0.00 07H TEH 3

65 DSI 1.84 22 P1 03H

-0.07 07H TEH 3

65 MAI 0.33 112 6

03H 0.05 0.50 03H 03H 3

66 NQI 0.47 103 3

01C 22.90 07C TEC 3

66 DSI 0.74 50 P1 01H

-0.02 07H TEH 3

66 MAI 0.43 111 6

01H 0.05 0.31 01H 01H 3

66 DSI 0.76 40 P1 02H

-0.02 07H TEH 3

66 MAI 0.36 105 6

02H 0.01 0.29 02H 02H 3

66 DSI 0.77 56 P1 03H 0.07 07H TEH 3

66 MAI 0.20 89 6

03H 0.05 0.48 03H 03H 3

67 NQI 0.58 112 3

02C 11.14 07C TEC 3

67 DSI 0.38 37 P1 03H 0.00 07H TEH 3

68 DSI 1.00 131 P1 01H 0.15 07H TEH 3

68 DSI 1.05 71 P1 03H

-0.05 07H TEH 3

68 DSI 0.93 83 P1 04H

-0.02 07H TEH 3

68 SAI 0.94 92 6

04H

-0.05 0.49 04H 04H 3

70 DSI 0.71 145 P1 01H 0.12 07H TEH 3

70 DSI 0.82 87 P1 03H

-0.22 07H TEH 3

70 SAI 0.39 95 6

03H 0.19 0.66 03H 03H 3

73 DSI 1.58 84 P1 03H 0.05 07H TEH 3

74 DSI 0.41 85 P1 04H 0.00 07H TEH 3

79 DSI 0.98 57 P1 02H

-0.05 07H TEH 3

79 DSI 0.97 84 P1 03H 0.05 07H TEH 3

79 DSI 0.81 92 P1 04H

-0.10 07H TEH 3

79 DSI 0.45 53 P1 05H 0.00 07H TEH 3

85 DSI 0.65 41 P1 01H 0.00 07H TEH 3

85 SAI 0.14 92 6

01K

-0.04 0.19 01H 01H 3

89 DSI 0.41 76 P1 04H 0.02 07H TEH

Beaver Valley Unit #1 Page 5 of 41 1 R1 5 S/G Examination Results 1 RC-E-1 B (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inchl Cr-Length Cr-Angle From To 3

92 DSI 0.97 80 P1 02H 0.02 07H TEH 3

92 SAI 1.03 92 6

02H 0.02 0.42 02H 02H 4

3 DSI 0.82 71 P1 01H

-0.12 07H TEH 4

3 DSI 0.65 61 P1 04H 0.03 07H TEH 4

5 DSI 0.94 89 P1 02H

-0.03 07H TEH 4

8 DSI 0.46 57 P1 01H 0.00 07H TEH 4

8 DSI 1.33 76 P1 02H

-0.09 07H TEH 4

8 DSI 0.89 58 P1 03H 0.00 07H TEH 4

10 DSI 1.18 97 P1 01H 0.00 07H TEH 4

12 DSI 0.89 47 P1 01H

-0.09 07H TEH 4

12 MAI 0.15 88 6

01H 0.00 0.32 01H 01H 4

13 DSI 1.67 78 P1 01H 0.00 07H TEH 4

13 MAI 0.92 88 6

01H 0.08 0.47 01H 01H 4

13 DSI 1.00 78 P1 02H

-0.06 07H TEH 4

15 DSI 0.80 86 P1 01H

-0.09 07H TEH 4

16 DSI 0.97 67 P1 O1H

-0.03 07H TEH 4

24 DSI 1.18 104 P1 01H 0.05 STH TEC 4

25 DSI 0.70 111 P1 O1H 0.02 STH TEC 4

25 DSI 0.48 96 P1 02H 0.05 STH TEC 4

27 DSI 1.03 92 P1 O1H

-0.03 07H TEH 4

29 DSI 2.02 105 P1 O1H

-0.20 07H TEH 4

29 MAI 0.74 93 6

O1H

-0.19 0.44 O1H O1H 4

29 DSI 0.40 142 P1 02H 0.00 07H TEH 4

29 DSI 0.37 42 P1 04H 0.11 07H TEH 4

31 DSI 1.62 83 P1 01H

-0.03 07H TEH 4

34 DSI 0.80 116 P1 03H

-0.09 07H TEH 4

35 DSI 0.58 58 P1 01H 0.09 07H TEH 4

35 DSI 1.30 80 P1 02H

-0.06 07H TEH 4

35 MAI 0.55 90 6

02H

-0.14 0.40 02H 02H 4

36 DSI 1.15 101 P1 02H

-0.17 07H TEH 4

36 MAI 0.87 83 6

02H

-0.06 0.56 02H 02H 4

36 DSI 0.91 76 P1 03H 0.23 07H TEH 4

36 DSI 0.88 70 P1 04H

-0.03 07H TEH 4

38 DSI 0.69 96 P1 01H

-0.14 STH TEC 4

38 DSI 0.46 103 P1 02H 0.26 STH TEC 4

39 DSI 0.48 33 P1 01H

-0.03 07H TEH 4

39 DSI 0.43 111 P1 02H

-0.13 07H TEH 4

44 DSI 0.61 84 P1-01H

-0.03 07H TEH 4

49 DSI 0.62 54 P1 01H

-0.06 07H TEH 4

49 DSI 0.22 52 P1 04H

-0.09 07H TEH 4

50 DSI 0.46 40 P1 01H 0.06 07H TEH 4

52 DSI 0.60 93 P1 01H 0.12 07H TEH 4

57 DSI 1.00 106 P1 01H 0.02 07H TEH 4

57 DSI 0.72 92 P1 02H 0.00 07H TEH 4

57 DSI 0.53 44 P1 03H 0.00 07H TEH 4

57 DSI 0.45 110 P1 04H

-0.05 07H TEH 4

58 DSI 1.29 71 P1 01H 0.00 07H TEH 4

60 DSI 0.91 93 P1 01H 0.02 07H TEH 4

60 MAI 0.50 106 6

01H

-0.05 0.28 01H 01H 4

60 DSI 0.50 86 P1 02H

-0.07 07H TEH 4

65 DSI 0.40 79 P1 O1H 0.00 07H TEH

Beaver Valley Unit #1 Page 6 of 41 1 R1 5 S/G Examination Results 1 RC-E-1 B (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 4

65 DSI 0.63 72 P1 02H 0.00 07H TEH 4

70 DSI 0.92 101 P1 01H

-0.20 07H TEH 4

70 DSI 0.61 40 P1 03H 0.00 07H TEH 4

72 DSI 0.45 73 P1 03H 0.00 07H TEH 4

74 DSI 0.35 88 P1 01H 0.05 07H TEH 4

75 DSI 0.49 97 P1 04H 0.00 07H TEH 4

76 DSI 1.19 79 P1 01H 0.00 07H TEH 4

76 SAI 1.10 88 6

01H

-0.03 0.43 01H 01H 4

76 DSI 0.51 96 P1 02H 0.12 07H TEH 4

82 DSI 0.52 54 P1 01 H 0.00 07H TEH 4

85 DSI 0.93 38 P1 02H

-0.03 07H TEH 4

85 SAI 0.46 95 6

02H

-0.08 0.36 02H 02H 4

85 DSI 1.40 74 P1 04H

-0.07 07H TEH 4

86 DSI 0.69 88 P1 011H 0.08 07H TEH 4

93 PCT 0.35 149 0

P1 02C

-0.10 07C TEC 4

94 PCT 0.89 126 13 P1 01C

-0.05 07C TEC 5

3 DSI 0.54 27 P1 02H 0.02 TEH TEC 5

3 DSI 0.52 97 P1 04H 0.10 TEH TEC 5

4 DSI 1.08 98 P1 01H 0.12 TEH TEC 5

4 DSI 0.47 81 P1 02H 0.07 TEH TEC 5

5 DSI 0.44 66 P1 01H 0.10 TEH TEC 5

6 DSI 1.57 88 P1 01H 0.10 TEH TEC 5

10 DSI 0.86 70 P1 01H 0.07 TEH TEC 5

13 DSI 0.63 77 P1 01H

-0.02 TEH TEC 5

13 DSI 1.69 67 P1 02H 0.14 TEH TEC 5

13 DSI 0.50 98 P1 04H

-0.14 TEH TEC 5

14 DSI 0.77 101 P1 01H

-0.05 TEH TEC 5

14 MAI 0.23 98 6

01H 0.00 0.37 01H 01H 5

14 DSI 0.49 29 P1 02H 0.05 TEH TEC 5

15 DSI 1.03 45 P1 011H 0.05 TEH TEC 5

15 SAI 0.25 97 6

011H

-0.04 0.30 011H 01H 5

16 DSI 1.28 90 P1 01H

-0.07 TEH TEC 5

20 DSI 0.57 76 P1 01H 0.08 STH TEC 5

20 DSI 0.66 99 P1 02H

-0.05 STH TEC 5

21 DSI 0.48 137 P1 02H

-0.10 TEH TEC 5

22 DSI 0.91 91 P1 01H

-0.15 TEH TEC 5

26 DSI 0.64 43 P1 01H 0.00 TEH TEC 5

26 MAI 0.35 102 6

01H

-0.03 0.29 01H 01H 5

28 DSI 0.69 94 P1 01 H 0.07 TEH TEC 5

29 DSI 0.43 93 P1 02H 0.00 TEH TEC 5

31 DSI 0.43 63 P1 011H 0.02 TEH TEC 5

32 DSI 0.92 104 P1 01H

-0.10 TEH TEC 5

32 DSI 0.33 60 P1 02H 0.00 TEH TEC 5

38 DSI 0.53 58 P1 01H

-0.05 TEH TEC 5

38 SAI 0.35 97 6

011H

-0.03 0.28 01H 01H 5

39 DSI 0.56 41 P1 02H 0.07 TEH TEC 5

40 DSI 1.59 69 P1 01H 0.15 TEH TEC 5

41 DSI 1.39 91 P1 01H 0.02 TEH TEC 5

41 DSI 0.31 60 P1 02H 0.05 TEH TEC 5

42 DSI 1.03 74 P1 011H

-0.10 TEH TEC 5

46 DSI 0.94 120 P1 01H 0.05 TEH TEC

Beaver Valley Unit #1 Page 7 of 41 1 R1 5 S/G Examination Results 1RC-E-1B (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inchl Cr-Length Cr-Angle From To 5

50 DSI 0.43 103 P1 02H 0.03 STH TEC 5

50 PTP 1.01 67 6

STH 1.20 STH STH 5

52 DSI 0.50 92 P1 04H

-0.02 TEH TEC 5

53 NQI 0.33 107 3

01H 25.38 TEH TEC 5

53 DSI 0.59 126 P1 02H 0.00 TEH TEC 5

53 MAI 0.21 92 6

02H 0.06 0.34 01H 02H 5

54 DSI 0.62 53 P1 01H 0.10 TEH TEC 5

54 DSI 0.88 89 P1 02H 0.05 TEH TEC 5

57 DSI 0.47 77 P1 01H

-0.05 TEH TEC 5

57 DSI 0.50 48 P1 02H 0.05 TEH TEC 5

59 DSI 1.18 113 P1 01H

-0.05 TEH TEC 5

60 DSI 0.63 83 P1 01H -0.02 TEH TEC 5

64 DSI 0.54 107 P1 01H 0.05 TEH TEC 5

65 DSI 0.61 144 P1 01H 0.05 TEH TEC 5

67 DSI 0.75 55 P1 02H 0.07 TEH TEC 5

68 DSI 0.56 62 P1 01H 0.02 TEH TEC 5

78 DSI 0.60 89 P1 02H

-0.05 TEH TEC 5

78 SAI 0.25 102 6

02H

-0.05 0.19 02H 02H 5

78 DSI 0.36 88 P1 03H

-0.02 TEH TEC 5

78 SAI 1.56 23 6

TSH

-1.62 0.29 TSH TSH 5

79 DSI 1.54 70 P1 02H 0.00 TEH TEC 5

79 DNT 3.10 181 P1 04H

-0.15 TEH TEC 5

79 SAI 0.36 88 6

04H 0.16 0.28 04H 04H 5

84 DSI 0.37 40 P1 05H 0.00 TEH TEC 5

86 SAI 1.22 19 6

TSH

-9.79 0.26 TSH TSH 5

88 DSI 0.49 59 P1 01H 0.07 TEH TEC 5

88 DSI 0.41 59 P1 04H 0.10 TEH TEC 5

93 PCT 1.03 139 0

P1 01C 0.05 TEH TEC 5

93 DSI 0.60 44 P1 04H 0.00 TEH TEC 5

94 PCT 0.65 130 11 P1 01C 0.00 TEH TEC 5

94 VOL 0.55 109 6

01C 0.00 01C 01C 5

94 PCT 1.16 126 13 P1 02C -0.10 TEH TEC 5

94 VOL 0.42 111 6

02C -0.10 02C 02C 6

1 DSI 0.53 87 P1 01H 0.05 TEH TEC 6

3 DSI 0.80 86 P1 01H 0.00 TEH TEC 6

4 DSI 0.36 158 P1 03H 0.07 TEH TEC 6

4 PSI 17.01 139 8

07H

-0.17 TEH TEC 6

4 CSI 0.20 74 11 07H

-0.01 33 07H 07H 6

5 DSI 1.25 76 P1 01H

-0.02 TEH TEC 6

5 DSI 0.78 84 P1 03H 0.15 TEH TEC 6

5 DSI 0.49 136 P1 05H 0.07 TEH TEC 6

6 DSI 0.80 39 P1 02H 0.12 TEH TEC 6

6 SAI 0.46 93 6

02H 0.00 0.51 02H 02H 6

6 DSI 0.83 24 P1 03H 0.00 TEH TEC 6

6 MAI 0.20 118 6

03H

-0.13 0.25 03H 03H 6

7 DSI 0.71 69 P1 01H -0.05 TEH TEC 6

7 DSI 0.73 69 P1 02H 0.07 TEH TEC 6

9 DSI 1.17 105 P1 01H 0.00 TEH TEC 6

9 DSI 0.83 75 P1 03H 0.07 TEH TEC 6

13 DSI 1.13 79 P1 01H 0.07 TEH TEC 6

14 DSI 1.23 85 P1 01H -0.02 TEH TEC

Beaver Valley Unit #1 Page 8 of 41 1 R15 S/G Examination Results 1RC-E-1B (TUBES WITH INDICATIONS)

Row Col End Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 6

14 MAI 0.63 96 6

01H

-0.14 0.37 01H 01H 6

16 DSI 0.43 44 P1 01H 0.05 TEH TEC 6

17 DSI 1.72 63 P1 01H 0.10 TEH TEC 6

19 DSI 1.84 84 P1 01H

-0.05 TEH TEC 6

19 DSI 0.32 62 P1 02H

-0.02 TEH TEC 6

21 DSI 0.95 52 P1 01H 0.05 TEH TEC 6

21 DSI 0.94 97 P1 02H

-0.05 TEH TEC 6

21 MAI 0.54 89 6

02H

-0.10 0.40 02H 02H 6

22 DSI 1.04 44 P1 01H 0.02 TEH TEC 6

22 MAI 0.27 111 6

01H 0.12 0.25 01H 01H 6

24 DSI 0.62 123 P1 02H

-0.10 1SH TEC 6

24 MAI 1.05 89 2

02H

-0.11 0.43 02H 02H 6

26 DSI 1.38 49 P1 01H

-0.05 TEH TEC 6

26 MAI 0.22 87 6

01H

-0.02 0.22 01H 01H 6

30 DSI 0.86 109 P1 01H

-0.16 STH TEC 6

30 DSI 0.75 97 P1 02H

-0.11 STH TEC 6

35 DSI 0.65 45 P1 01H 0.02 TEH TEC 6

35 SAI 0.32 95 6

01H

-0.02 0.47 01H 01H 6

38 DSI 0.78 107 P1 01H

-0.05 TEH TEC 6

38 SAI 0.74 86 6

01H 0.00 0.61 01H 01H 6

40 DSI 0.38 78 P1 01H 0.05 TEH TEC 6

40 DSI 0.68 87 P1 04H

-0.02 TEH TEC 6

40 DSI 0.29 109 P1 05H 0.10 TEH TEC 6

41 DSI 0.93 128 P1 01H

-0.07 TEH TEC 6

44 DSI 0.65 127 P1 01H 0.02 TEH TEC 6

46 DSI 1.07 74 P1 01H 0.05 TEH TEC 6

48 DSI 1.00 108 P1 01H 0.07 TEH TEC 6

50 DSI 1.26 61 P1 01H

-0.10 TEH TEC 6

50 SAI 0.35 81 6

01H

-0.11 0.42 01H 01H 6

56 DSI 0.37 107 P1 01H 0.07 TEH TEC 6

61 DSI 0.72 62 P1 01H 0.07 TEH TEC 6

65 DSI 0.54 46 P1 01H 0.02 TEH TEC 6

75 DSI 0.43 51 P1 03H 0.05 TEH TEC 6

78 DSI 0.92 115 P1 01H 0.20 TEH TEC 6

78 DSI 0.42 67 P1 03H 0.00 TEH TEC 6

79 PVN 0.14 49 3

TSH 0.10 TSH TSH 6

83 DSI 0.73 106 P1 01H 0.15 TEH TEC 6

86 DSI 0.49 36 P1 02H 0.00 TEH TEC 6

87 DSI 0.60 66 P1 02H

-0.07 TEH TEC 6

87 DSI 0.72 100 P1 04H 0.12 TEH TEC 6

87 SAI 0.51 95 6

04H 0.07 0.43 04H 04H 6

88 PVN 3.15 219 3

TSH 0.21 TSH TSH 6

90 DSI 0.90 18 P1 05H 0.02 TEH TEC 6

90 SAI 0.17 82 6

05H

-0.03 0.29 05H 05H 7

1 PCT 0.70 129 23 P1 02C 0.10 TEH TEC 7

5 DSI 0.53 104 P1 02H 0.12 TEH TEC 7

5 MAI 0.68 95 6

02H 0.05 0.54 02H 02H 7

6 DSI 1.13 112 P1 01H 0.12 TEH TEC 7

9 DSI 1.45 90 P1 01H 0.07 TEH TEC 7

9 DSI 0.64 116 P1 02H 0.12 TEH TEC 7

9 DSI 0.45 89 P1 03H 0.02 TEH TEC

Beaver Valley Unit #1 Page 9 of 41 1 R15 S/G Examination Results 1 RC-E-1 B (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 7

9 DSI 0.90 50 P1 04H 0.05 TEH TEC 7

9 MAI 0.35 102 6

04H 0.05 0.25 04H 04H 7

10 DSI 1.03 64 P1 01H 0.05 TEH TEC 7

10 MAI 0.83 95 6

01H

-0.12 0.52 01H 01H 7

10 DSI 0.86 35 P1 02H 0.00 TEH TEC 7

10 SAI 0.27 83 6

02H

-0.15 0.37 02H 02H 7

12 DSI 0.84 61 P1 01H 0.05 TEH TEC 7

12 DSI 1.52 57 P1 02H 0.00 TEH TEC 7

12 DSI 0.51 27 P1 03H 0.07 TEH TEC 7

13 DSI 1.48 118 P1 01H 0.02 TEH TEC 7

13 DSI 1.44 17 P1 02H 0.14 TEH TEC 7

13 SPR 1.92 26 P1 02H 0.00 TEH TEC 7

13 SAI 0.14 102 6

02H 0.00 0.20 02H 02H 7

13 DSI 0.97 172 P1 04H

-0.05 TEH TEC 7

13 SAI 0.20 78 6

04H 0.00 0.35 04H 04H 7

14 DSI 0.77 106 P1 011H

-0.05 TEH TEC 7

14 DSI 1.55 109 P1 02H

-0.07 TEH TEC 7

17 DSI 0.67 44 P1 01H 0.05 TEH TEC 7

17 MAI 0.42 81 6

01H 0.07 0.32 01H 01H 7

18 DSI 1.52 98 P1 01H

-0.12 TEH TEC 7

21 DSI 0.68 68 P1 01H 0.02 TEH TEC 7

23 DSI 0.99 97 P1 01H

-0.11 STH TEC 7

23 DSI 0.88 43 P1 02H 0.00 STH TEC 7

23 DSI 0.25 161 P1 03H 0.08 STH TEC 7

23 SAI 1.35 99 2

03H 0.01 0.63 03H 03H 7

23 DSI 0.79 68 P1 04H

-0.03 STH TEC 7

25 DSI 0.50 60 P1 01H

-0.02 STH TEC 7

28 DSI 0.31 97 P1 01H

-0.07 TEH TEC 7

28 SAI 0.18 109 6

TSH 0.18 0.23 TSH TSH 7

31 DSI 0.60 40 P1 02H 0.02 STH TEC 7

34 DSI 0.40 108 P1 01H 0.05 STH TEC 7

34 MAI 0.76 96 2

01H 0.17 0.75 01H 01H 7

34 DSI 0.52 115 P1 02H 0.05 STH TEC 7

34 MAI 0.78 105 2

02H 0.00 0.36 02H 02H 7

34 DSI 0.81 116 P1 03H 0.00 STH TEC 7

34 MAI 0.71 104 2

03H 0.28 0.23 03H 03H 7

35 SAI 0.22 89 6

TSH 0.60 0.40 TSH TSH 7

36 DSI 0.66 51 P1 02H 0.00 STH TEC 7

38 DSI 0.88 91 P1 011H 0.07 STH TEC 7

38 PTP 0.80 82 6

STH 1.21 STH STH 7

40 SAI 0.19 81 6

TSH 0.17 0.24 TSH TSH 7

44 DSI 0.90 82 P1 011H

-0.05 TEH TEC 7

44 DSI 0.54 95 P1 02H

-0.02 TEH TEC 7

45 DSI 0.68 79 P1 01H

-0.02 TEH TEC 7

50 DSI 0.76 128 P1 01H

-0.12 TEH TEC 7

50 SAI 0.25 94 6

01H

-0.14 0.35 01H 01H 7

51 DSI 0.80 97 P1 011H

-0.02 TEH TEC 7

53 PVN 0.49 45 2

07H 0.67 07C 07H 7

53 PVN 0.70 37 P2 07H 2.51 07C 07H 7

54 SPR 1.88 202 P1 02H 0.00 TEH TEC 7

54 DSI 1.12 22 P1 02H 0.22 TEH TEC

Beaver Valley Unit #1 Page 10 of 41 1 R1 5 S/G Examination Results 1RC-E-1B (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 7

54 SAI 0.24 82 6

02H

-0.07 0.40 02H 02H 7

56 DSI 0.77 101 P1 01H

-0.05 TEH TEC 7

57 DSI 0.90 77 P1 01H 0.00 TEH TEC 7

58 DSI 1.48 126 P1 01H 0.05 TEH TEC 7

63 DSI 0.45 54 P1 01H

-0.02 TEH TEC 7

65 DSI 0.59 48 P1 01H 0.07 TEH TEC 7

68 PVN 0.51 40 6

TSH 4.67 TSH TSH 7

68 PVN 0.69 41 6

TSH 1.63 TSH TSH 7

72 DSI 1.03 61 P1 01H 0.12 TEH TEC 7

72 PVN 0.45 89 2

07H 17.27 07C 07H 7

73 DSI 0.57 36 P1 01H 0.05 TEH TEC 7

74 DSI 1.93 138 P1 01H 0.02 TEH TEC 7

74 DSI 0.45 118 P1 07H 0.10 TEH TEC 7

78 DSI 1.09 151 P1 01H 0.20 TEH TEC 7

78 SPR 1.84 159 P1 011H 0.00 TEH TEC 7

78 SAI 0.63 91 6

01H 0.19 0.33 01H 01H 7

81 DSI 0.78 147 P1 01H 0.12 TEH TEC 7

84 DSI 1.44 18 P1 04H 0.02 TEH TEC 7

84 SPR 1.56 19 P1 04H 0.00 TEH TEC 7

84 SAI 0.20 85 6

04H

-0.17 0.21 04H 04H 7

88 DSI 0.71 49 P1 02H 0.00 TEH TEC 7

88 SAI 0.32 98 6

02H 0.00 0.24 02H 02H 7

88 DSI 0.40 40 P1 04H 0.05 TEH TEC 7

89 DSI 0.64 53 P1 02H 0.02 TEH TEC 7

89 SAI 0.49 88 6

02H 0.03 0.48 02H 02H 7

91 PCT 0.32 134 4

P1 02C 0.20 TEH TEC 7

92 PCT 1.27 134 7

P1 01C

-0.05 TEH TEC 7

93 DSI 0.61 155 P1 01H 0.02 TEH TEC 7

93 SVI 0.33 129 P2 01H 0.00 0.40 30 01H 01H 7

94 PCT 0.32 126 13 P1 01C 0.00 TEH TEC 8

2 PCT 0.58 135 12 P1 02C 0.02 TEH TEC 8

5 DSI 0.51 105 P1 01H 0.07 TEH TEC 8

6 DSI 1.06 97 P1 01H 0.22 TEH TEC 8

8 DSI 0.58 84 P1 01H 0.05 TEH TEC 8

13 DSI 1.32 58 P1 01H

-0.15 TEH TEC 8

13 DSI 0.52 147 P1 06H

-0.03 TEH TEC 8

17 DSI 0.44 73 P1 01H 0.05 TEH TEC 8

18 DSI 0.68 77 P1 01H 0.05 TEH TEC 8

20 DSI 0.72 112 P1 01H 0.12 TEH TEC 8

21 DSI 0.49 59 P1 01H 0.10 TEH TEC 8

21 SAI 0.30 81 6

TSH 0.02 0.25 TSH TSH 8

28 DSI 0.48 88 P1 01H

-0.03 STH TEC 8

31 DSI 0.44 87 P1 02H 0.12 STH TEC 8

34 DSI 0.96 108 P1 01H 0.05 STH TEC 8

39 DSI 1.16 58 P1 01H

-0.02 STH TEC 8

44 DSI 0.73 34 P1 01H 0.02 TEH TEC 8

44 SAI 0.17 73 6

01H 0.06 0.18 01H 01H 8

45 DSI 1.09 75 P1 01H 0.00 TEH TEC 8

47 DSI 1.30 105 P1 01H

-0.05 TEH TEC 8

50 DSI 1.03 107 P1 01H

-0.12 TEH TEC 8

58 DSI 0.46 37 P1 02H 0.02 TEH TEC

Beaver Valley Unit #1 Page 11 of 41 1 R1 5 S/G Examination Results 1RC-E-1B (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 8

64 DSI 0.85 57 P1 01H 0.02 TEH TEC 8

64 SAI 0.61 85 6

01H

-0.03 0.33 01H 01H 8

69 PVN 2.56 50 6

TSH 5.28 TSH TSH 8

74 DSI 1.36 99 P1 01H 0.07 TEH TEC 8

82 DSI 0.44 129 P1 01H 0.02 TEH TEC 8

82 DSI 0.90 64 P1 02H 0.00 TEH TEC 8

88 DSI 0.35 88 P1 01H 0.00 TEH TEC 9

3 DSI 0.40 150 P1 02H

-0.05 TEH TEC 9

5 DSI 0.82 50 P1 01H 0.03 TEH TEC 9

5 SAI 0.34 107 6

01H

-0.12 0.42 01H 01H 9

8 DSI 0.65 50 P1 01H 0.08 TEH TEC 9

8 MAI 0.36 85 6

01H

-0.16 0.42 01H 01H 9

8 DSI 0.76 41 P1 02H 0.05 TEH TEC 9

8 SAI 0.23 89 6

02H 0.02 0.30 02H 02H 9

8 DSI 0.71 28 P1 04H 0.05 TEH TEC 9

9 SPR 1.58 61 P1 01H 0.00 TEH TEC 9

9 DSI 1.56 59 P1 01H 0.03 TEH TEC 9

9 SAI 0.61 92 6

01H 0.01 0.47 01H O1H 9

10 DSI 0.56 75 P1 01H

-0.03 TEH TEC 9

10 MAI 0.40 105 6

01H

-0.03 0.37 01H 01H 9

10 DSI 0.24 47 P1 05H 0.05 TEH TEC 9

12 DSI 0.45 27 P1 01H 0.00 TEH TEC 9

15 DSI 1.44 59 P1 01H 0.03 TEH TEC 9

15 DSI 0.71 72 P1 02H

-0.03 TEH TEC 9

15 DSI 0.82 104 P1 03H

-0.18 TEH TEC 9

15 SAI 0.28 109 6

03H

-0.13 0.25 03H 03H 9

19 DSI 0.86 78 P1 01H 0.07 TEH TEC 9

19 SAI 0.62 97 6

01H 0.05 0.37 01H 01H 9

20 DSI 0.26 39 P1 01H 0.05 TEH TEC 9

20 SAI 0.27 102 6

01H 0.02 0.49 01H 01H 9

20 DSI 0.74 49 P1 02H

-0.07 TEH TEC 9

20 SAI 0.36 102 6

02H

-0.13 0.60 02H 02H 9

22 DSI 0.98 92 P1 01H

-0.07 STH TEC 9

22 DS1 1.10 92 P1 01H

-0.13 STH TEC 9

24 DSI 0.49 50 P1 01H 0.02 TEH TEC 9

25 DSI 0.92 78 P1 01H 0.00 STH TEC 9

25 OBS TEH TEH 9

26 DSI 0.30 102 P1 01H 0.05 TEH TEC 9

28 DSI 1.05 104 P1 01H 0.05 STH TEC 9

29 DSI 0.46 70 P1 01H 0.00 STH TEC 9

29 NQI 1.12 124 3

06C 15.49 STH TEC 9

32 DSI 0.70 131 P1 01H

-0.16 STH TEC 9

34 PTP 0.71 88 4

STH 1.39 STH STH 9

37 DSI 0.54 83 P1 01H 0.02 STH TEC 9

38 NQI 0.35 129 3

06C 18.56 STH TEC 9

39 DSI 0.40 80 P1 01H

-0.08 STH TEC 9

40 PTP 0.25 56 6

STH 1.13 STH STH 9

46 DSI 0.42 44 P1 01H 0.05 TEH TEC 9

48 DSI 1.47 93 P1 01H

-0.14 TEH TEC 9

48 DSI 0.87 108 P1 02H 0.15 TEH TEC 9

59 DSI 1.66 85 P1 01H 0.07 TEH TEC

Beaver Valley Unit #1 Page 12 of 41 1 R1 5 S/G Examination Results 1 RC-E-1 B (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inchl Cr-Length Cr-Angle From To 9

59 MAI 0.77 96 6

01H 0.03 0.43 01H 01H 9

67 DSI 0.79 94 P1 01H

-0.12 TEH TEC 9

70 DSI 0.63 64 P1 01H

-0.02 TEH TEC 9

70 DSI 0.31 55 P1 03H 0.07 TEH TEC 9

72 DSI 0.95 76 P1 01H 0.02 TEH TEC 9

72 DSI 0.76 61 P1 02H

-0.02 TEH TEC 9

73 DSI 0.43 103 P1 02H

-0.02 TEH TEC 9

74 DSI 0.79 42 P1 02H 0.05 TEH TEC 9

74 SAI 0.38 96 6

02H

-0.05 0.31 02H 02H 9

75 DSI 1.72 100 P1 01H

-0.05 TEH TEC 9

75 SAI 1.13 93 6

01H 0.04 0.40 01H 01H 9

75 DSI 0.71 111 P1 02H

-0.10 TEH TEC 9

79 DSI 0.74 120 P1 01H 0.20 TEH TEC 9

79 DSI 1.06 71 P1 02H

-0.10 TEH TEC 9

79 DSI 0.76 37 P1 03H 0.05 TEH TEC 9

79 SAI 0.43 97 6

03H 0.11 0.40 03H 03H 9

79 DSI 0.71 72 P1 04H

-0.02 TEH TEC 9

81 DSI 1.12 90 P1 04H

-0.15 TEH TEC 9

82 DSI 0.87 70 P1 01H 0.00 TEH TEC 9

82 DSI 0.65 75 P1 02H 0.00 TEH TEC 9

83 DSI 0.73 58 P1 01H 0.00 TEH TEC 9

83 SAI 0.42 89 6

01H

-0.08 0.31 01H 01H 9

83 DSI 1.17 75 P1 02H

-0.02 TEH TEC 9

83 SAI 0.46 101 6

02H 0.00 0.38 02H 02H 9

84 DSI 0.68 55 P1 02H 0.00 TEH TEC 9

84 SAI 0.26 94 6

02H

-0.05 0.26 02H 02H 9

84 DSI 0.71 43 P1 03H 0.02 TEH TEC 9

84 SAI 0.39 101 6

03H 0.00 0.29 03H 03H 9

84 DSI 0.75 26 P1 04H 0.05 TEH TEC 9

84 SAI 0.18 94 6

04H

-0.11 0.21 04H 04H 9

86 DSI 0.79 50 P1 02H 0.07 TEH TEC 9

86 MAI 0.32 106 6

02H

-0.01 0.33 02H 02H 9

88 DSI 0.65 51 P1 03H 0.02 TEH TEC 9

91 DSI 0.46 65 P1 02H 0.02 TEH TEC 9

91 DSI 0.71 70 P1 04H 0.05 TEH TEC 9

91 DSI 0.92 78 P1 05H

-0.05 TEH TEC 9

93 PCT 1.30 120 24 P1 02C 0.07 TEH TEC 9

93 VOL 0.93 111 6

02C 0.07 02C 02C 10 2

PCT 0.87 132 6

P1 02C -0.13 TEH TEC 10 3

PCT 0.46 147 0

P1 03C 0.05 TEH TEC 10 4

DSI 0.65 74 P1 01H 0.05 TEH TEC 10 8

DSI 0.77 52 P1 01H 0.05 TEH TEC 10 9

DSI 0.54 51 P1 01H 0.05 TEH TEC 10 10 DSI 0.80 72 P1 01H

-0.02 TEH TEC 10 11 DSI 1.53 97 P1 01H 0.10 TEH TEC 10 11 DSI 0.90 93 P1 02H

-0.15 TEH TEC 10 12 DSI 0.53 74 P1 01H 0.10 TEH TEC 10 12 DSI 0.30 27 P1 02H 0.02 TEH TEC 10 13 DSI 1.82 96 P1 01H 0.00 TEH TEC 10 14 DSI 0.38 77 P1 01H 0.00 TEH TEC 10 14 DSI 0.40 83 P1 02H 0.00 TEH TEC

Beaver Valley Unit #1 Page 13 of 41 1 R1 5 S/G Examination Results 1RC-E-1B (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 10 15 DSI 1.16 59 P1 01H 0.05 TEH TEC 10 15 DSI 0.46 83 P1 02H 0.00 TEH TEC 10 16 DSI 1.96 82 P1 01H 0.00 TEH TEC 10 17 DSI 0.62 69 P1 01H 0.00 TEH TEC 10 17 DSI 0.52 46 P1 02H 0.00 TEH TEC 10 20 DSI 1.43 106 P1 01H 0.07 TEH TEC 10 20 NQI 0.92 114 3

04C 42.63 TEH TEC 10 21 DSI 0.53 73 P1 01H 0.00 TEH TEC 10 23 DSI 0.49 65 P1 01H

-0.05 TEH TEC 10 23 MAI 0.27 101 6

01H

-0.05 0.23 TSH 01H 10 23 NQI 0.34 130 3

TSH 30.90 TEH TEC 10 25 DSI 0.83 89 P1 01H

-0.05 STH TEC 10 26 DSI 0.30 57 P1 01H 0.00 STH TEC 10 27 SAI 0.13 87 6

TSH 0.79 0.53 TSH TSH 10 31 DSI 0.33 69 P1 01H 0.05 STH TEC 10 33 DSI 1.11 76 P1 01H

-0.12 STH TEC 10 34 SAI 0.16 80 6

TSH 2.76 0.25 TSH TSH 10 39 DSI 0.70 86 P1 01H 0.00 STH TEC 10 48 DSI 0.54 59 P1 01H -0.03 STH TEC 10 53 DSI 0.39 56 P1 01H

-0.12 TEH TEC 10 53 DSI 0.78 49 P1 02H 0.02 TEH TEC 10 53 SAI 0.32 98 6

02H

-0.01 0.53 02H 02H 10 56 DSI 0.44 52 P1 01H -0.02 TEH TEC 10 57 PVN 0.67 42 3

TSH 2.90 TSH TSH 10 61 PTP 2.21 78 6

STH 1.30 STH STH 10 63 DSI 0.83 46 P1 01H 0.17 TEH TEC 10 65 DSI 1.05 64 P1 01H 0.02 TEH TEC 10 66 DSI 1.53 107 P1 01H

-0.05 TEH TEC 10 66 DSI 2.05 113 P1 02H 0.10 TEH TEC 10 66 MAI 0.88 82 6

02H 0.02 0.40 02H 02H 10 69 DNI 1.79 107 5

07H 13.48 TEH TEC 10 72 DSI 0.99 154 P1 01H 0.20 TEH TEC 10 81 PVN 0.26 37 6

TSH 3.79 TSH TSH 10 82 DSI 0.43 38 P1 02H

-0.05 TEH TEC 10 88 PVN 0.59 37 3

TSH 3.54 TSH TSH 10 92 PCT 1.74 120 24 P1 01C -0.17 TEH TEC 10 93 DSI 0.40 141 P1 01H 0.12 TEH TEC 11 3

PCT 0.63 139 0

P1 01C -0.13 TEH TEC 11 3

VOL 0.36 126 6

01C -0.13 01C 01C 11 3

VOL 0.35 126 6

01C -0.13 01C 01C 11 4

DSI 0.30 136 P1 03H 0.03 TEH TEC 11 7

DSI 0.64 52 P1 03H 0.05 TEH TEC 11 9

DSI 1.13 77 P1 01H 0.00 TEH TEC 11 12 DSI 0.69 80 P1 01H 0.05 TEH TEC 11 14 DSI 0.84 72 P1 01H 0.12 TEH TEC 11 17 DSI 0.52 65 P1 01H 0.12 TEH TEC 11 19 DSI 1.16 64 P1 01H 0.02 TEH TEC 11 20 DSI 1.88 94 P1 01H 0.10 TEH TEC 11 20 NOI 0.61 111 3

TSC 5.31 TEH TEC 11 21 DSI 0.45 81 P1 01H 0.05 TEH TEC 11 22 DSI 0.78 65 P1 03H 0.00 1SH TEC

Beaver Valley Unit #1 Page 14 of 41 1 R1 5 S/G Examination Results 1RC-E-1B (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 11 24 DSI 0.67 58 P1 01H 0.00 STH TEC 11 28 DSI 1.00 105 P1 01H 0.17 STH TEC 11 28 DSI 0.84 110 P1 02H 0.07 STH TEC 11 29 DSI 0.41 86 P1 02H 0.07 1SH TEC 11 29 DSI 0.20 125 P1 03H 0.07 1SH TEC 11 31 DSI 0.50 58 P1 01H

-0.07 STH TEC 11 31 DSI 0.47 69 P1 02H 0.02 STH TEC 11 37 SAI 0.15 99 6

TSH 2.71 0.61 TSH TSH 11 38 DSI 0.64 105 P1 01H

-0.10 STH TEC 11 38 MAI 0.75 119 2

01H

-0.07 0.40 01H 01H 11 38 DSI 0.93 125 P1 02H

-0.10 STH TEC 11 39 DSI 0.38 100 P1 04H 0.07 1SH TEC 11 40 PTP 1.07 69 6

STH 1.21 STH STH 11 41 DSI 0.51 97 P1 01H

-0.05 STH TEC 11 41 PTP 0.63 95 6

STH 1.13 STH STH 11 42 SAI 0.16 87 6

TSH 0.65 0.71 TSH TSH 11 47 PTP 0.83 69 4

STH 1.04 STH STH 11 50 DSI 1.07 84 P1 01H

-0.08 STH TEC 11 53 DSI 0.58 99 P1 01H 0.00 TEH TEC 11 58 DSI 0.30 78 P1 02H

-0.02 TEH TEC 11 60 DSI 0.90 93 P1 01H

-0.02 TEH TEC 11 61 DSI 0.51 50 P1 01H 0.05 TEH TEC 11 66 DSI 0.77 142 P1 01H

-0.15 TEH TEC 11 66 MAI 0.14 96 6

01H 0.07 0.31 01H 01H 11 69 DSI 0.76 60 P1 01H 0.05 TEH TEC 11 72 DSI 0.48 33 P1 02H 0.05 TEH TEC 11 82 DSI 0.73 26 P1 01H 0.00 TEH TEC 11 82 SAI 0.22 122 6

01H

-0.03 0.26 01H 01H 11 84 DSI 0.51 29 P1 01H 0.05 TEH TEC 11 91 PCT 0.62 131 4

P1 02C 0.15 TEH TEC 12 2

NOI 0.67 112 3

01H 34.69 TEH TEC 12 2

DSI 0.28 44 P1 01H 0.03 TEH TEC 12 2

SAI 0.29 97 6

O1H 0.06 0.40 01H 02H 12 3

DSI 1.58 94 P1 01H 0.26 TEH TEC 12 3

SAI 0.48 90 6

01H 0.10 0.46 01H 01H 12 4

DSI 0.34 43 P1 03H 0.05 TEH TEC 12 8

DSI 1.08 80 P1 02H 0.00 1SH TEC 12 8

DSI 0.53 86 P1 03H 0.00 1SH TEC 12 8

DSI 0.63 61 P1 04H 0.11 1SH TEC 12 9

DSI 0.55 74 P1 01H 0.10 TEH TEC 12 11 DSI 1.37 80 P1 01H 0.05 TEH TEC 12 11 DSI 0.17 61 P1 02H 0.03 TEH TEC 12 19 DSI 0.96 123 P1 01H

-0.12 TEH TEC 12 19 SAI 0.18 65 6

01H

-0.24 0.22 01H 01H 12 19 DSI 1.27 75 P1 02H 0.07 TEH TEC 12 19 MAI 0.56 96 6

02H 0.04 0.60 02H 02H 12 20 DSI 0.66 43 P1 01H 0.00 TEH TEC 12 20 SAI 0.19 107 6

01H

-0.06 0.22 01H 01H 12 20 DSI 0.68 51 P1 02H 0.00 TEH TEC 12 24 DSI 0.34 142 P1 01H 0.05 STH TEC 12 25 SAI 0.13 84 6

TSH 0.78 0.35 TSH TSH

Beaver Valley Unit #1 Page 15 of 41 1 R1 5 S/G Examination Results 1 RC-E-1 B (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 12 28 DSI 0.74 60 P1 01H 0.03 STH TEC 12 28 DSI 0.85 89 P1 02H 0.00 STH TEC 12 31 DSI 1.06 93 P1 01H

-0.05 STH TEC 12 34 DSI 1.15 123 P1 01H 0.31 STH TEC 12 36 SAI 0.21 88 6

TSH 3.40 0.50 TSH TSH 12 37 DSI 0.52 88 P1 01H 0.07 TEH TEC 12 37 DSI 0.31 78 P1 02H 0.07 TEH TEC 12 39 DSI 0.59 119 P1 01H

-0.19 STH TEC 12 39 SAI 0.62 94 2

01H

-0.06 0.43 01H 01H 12 39 DSI 0.62 48 P1 02H 0.02 STH TEC 12 39 SAI 0.82 106 2

02H 0.04 0.53 02H 02H 12 42 SAI 0.17 96 6

TSH 3.23 0.86 TSH TSH 12 43 DSI 0.60 103 P1 01H 0.05 STH TEC 12 44 DSI 0.49 65 P1 02H 0.03 STH TEC 12 47 DSI 0.45 64 P1 02H 0.03 STH TEC 12 51 DSI 0.63 122 P1 01H 0.00 TEH TEC 12 51 SAI 0.26 115 6

TSH 0.35 0.39 TSH TSH 12 52 SAI 0.07 103 6

TSH 0.57 0.32 TSH TSH 12 54 DSI 0.69 102 P1 01H 0.08 STH TEC 12 54 DSI 0.84 56 P1 02H 0.11 STH TEC 12 55 DSI 0.26 86 P1 01H 0.12 TEH TEC 12 55 SAI 0.23 93 6

TSH 0.14 0.19 TSH TSH 12 58 DSI 0.53 61 P1 01H 0.05 TEH TEC 12 60 DSI 0.72 55 P1 01H 0.07 TEH TEC 12 64 DSI 1.16 64 P1 02H 0.00 TEH TEC 12 65 DSI 0.89 54 P1 01H

-0.02 TEH TEC 12 70 DSI 0.47 60 P1 04H 0.05 TEH TEC 12 75 DSI 0.86 100 P1 01H

-0.02 TEH TEC 12 75 DSI 0.28 25 P1 05H 0.07 TEH TEC 12 77 DSI 0.79 140 P1 01H 0.12 TEH TEC 12 77 SAI 0.69 100 6

01H 0.04 0.31 01H 01H 12 80 DSI 0.45 48 P1 01H

-0.02 TEH TEC 12 81 PVN 0.43 34 6

TSH 1.07 TSH TSH 12 84 PVN 1.27 41 3

TSH 0.30 TSH TSH 12 87 DSI 0.54 156 P1 01H

-0.10 TEH TEC 12 87 DSI 0.62 61 P1 02H 0.02 TEH TEC 12 87 DSI 0.56 94 P1 03H

-0.02 TEH TEC 12 90 DSI 0.34 75 P1 04H 0.10 TEH TEC 12 91 PCT 0.26 133 1

P1 02C

-0.05 TEH TEC 12 91 VOL 0.37 158 6

02C -0.05 02C 02C 12 91 PVN 0.62 42 6

TSH 1.36 TSH TSH 12 92 PCT 1.54 128 13 P1 01C -0.05 TEH TEC 12 93 PCT 0.50 143 0

P1 05C -0.17 TEH TEC 13 3

DSI 1.51 99 P1 01H 0.10 TEH TEC 13 3

DSI 0.38 122 P1 03H 0.16 TEH TEC 13 4

PCT 1.05 124 17 P1 02C 0.03 TEH TEC 13 7

DSI 0.34 99 P1 01H 0.08 TEH TEC 13 9

DSI 0.58 45 P1 02H

-0.03 TEH TEC 13 10 DSI 0.60 79 P1 01H 0.10 TEH TEC 13 12 NQI 0.66 118 3

06H 36.62 TEH TEC 13 14 DSI 0.90 39 P1 01H

-0.05 TEH TEC

Beaver Valley Unit #1 Page 16 of 41 1 R1 5 S/G Examination Results 1RC-E-1B (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 13 14 MAI 0.73 96 6

01H

-0.04 0.42 01H 01H 13 14 DSI 0.37 64 P1 02H 0.12 TEH TEC 13 15 DSI 0.87 71 P1 01H 0.00 TEH TEC 13 15 MAI 0.37 93 6

01H 0.01 0.30 01H 01H 13 18 DSI 0.56 69 P1 01H 0.10 TEH TEC 13 20 DSI 0.35 59 P1 01H 0.07 TEH TEC 13 20 DSI 0.38 61 P1 02H 0.10 TEH TEC 13 21 DSI 0.51 66 P1 02H 0.07 TEH TEC 13 21 SAI 0.44 110 6

02H

-0.07 0.32 02H 02H 13 22 DSI 1.01 116 P1 01H

-0.07 TEH TEC 13 22 DSI 0.46 94 P1 02H 0.05 TEH TEC 13 23 DSI 0.52 110 P1 02H

-0.02 TEH TEC 13 23 SAI 0.44 99 6

02H

-0.03 0.35 02H 02H 13 25 DSI 0.53 78 P1 03H

-0.14 2SH TEC 13 28 DSI 0.97 113 P1 01H

-0.12 STH TEC 13 28 DSI 0.66 64 P1 02H 0.22 STH TEC 13 36 PTP 0.55 57 6

STH 1.16 STH STH 13 38 DSI 0.87 114 P1 02H

-0.15 STH TEC 13 43 DSI 0.28 75 P1 01H

-0.05 TEH TEC 13 43 DSI 0.55 93 P1 02H

-0.02 TEH TEC 13 43 SAI 0.24 97 6

02H

-0.09 0.35 02H 02H 13 44 DSI 0.75 108 P1 01H 0.03 STH TEC 13 47 DSI 0.82 102 P1 01H 0.00 STH TEC 13 48 DSI 0.88 104 P1 01H

-0.08 STH TEC 13

-50 DSI 0.75 62 P1 01H

-0.03 STH TEC 13 50 DSI 0.71 33 P1 02H 0.08 STH TEC 13 52 DSI 0.57 75 P1 03H

-0.03 STH TEC 13 53 DSI 1.88 105 P1 01H

-0.05 TEH TEC 13 53 DSI 0.87 96 P1 03H 0.00 TEH TEC 13 53 SAI 0.60 106 6

03H

-0.11 0.40 03H 03H 13 53 DSI 0.56 117 P1 04H

-0.02 TEH TEC 13 53 MAI 0.19 100 6

TSH 0.50 0.90 TSH TSH 13 55 DSI 0.32 88 P1 03H 0.17 STH TEC 13 55 NQI 0.55 138 3

TSC 1.73 STH TEC 13 69 DSI 1.42 93 P1 01H 0.15 TEH TEC 13 69 DSI 0.45 91 P1 02H

-0.02 TEH TEC 13 69 DSI 0.81 79 P1 03H

-0.10 TEH TEC 13 69 DSI 0.35 91 P1 04H 0.15 TEH TEC 13 71 DSI 0.53 48 P1 03H 0.05 TEH TEC 13 71 PVN 0.69 44 6

TSH

-5.80 TSH TSH 13 73 DSI 0.91 64 P1 01H

-0.02 TEH TEC 13 73 MAI 0.47 95 6

01H

-0.08 0.26 01H 01H 13 73 DSI 0.29 38 P1 02H 0.02 TEH TEC 13 74 DSI 0.39 61 P1 01H 0.05 TEH TEC 13 78 DSI 0.74 52 P1 01H 0.10 TEH TEC 13 78 DSI 0.78 26 P1 02H 0.07 TEH TEC 13 78 SAI 0.24 93 6

02H 0.05 0.24 02H 02H 13 80 DSI 0.47 36 P1 01H 0.07 TEH TEC 13 90 PCT 0.71 134 4

P1 02C 0.17 TEH TEC 13 90 VOL 0.23 122 6

02C 0.16 02C 02C 13 91 PCT 0.80 124 16 P1 01C -0.07 TEH TEC

Beaver Valley Unit #1 Page 17 of 41 1 R15 S/G Examination Results 1 RC-E-1 B (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 14 6

DSI 2.00 95 P1 01H 0.13 TEH TEC 14 6

SAI 1.05 91 6

01H 0.01 0.59 01H 01H 14 8

DSI 0.73 57 P1 01H 0.00 TEH TEC 14 11 DSI 0.72 48 P1 01H 0.08 TEH TEC 14 11 MAI 0.47 98 6

01H 0.18 0.52 01H 01H 14 13 DSI 1.06 105 P1 01H 0.15 TEH TEC 14 13 MAI 0.91 95

.6 01H 0.07 0.52 01H 01H 14 13 DSI 1.17 75 P1 02H 0.00 TEH TEC 14 13 DSI 0.71 137 P1 03H 0.20 TEH TEC 14 15 DSI 0.67 94 P1 01H 0.05 TEH TEC 14 20 DSI 0.52 92 P1 01H 0.05 TEH TEC 14 23 DSI 1.10 54 P1 01H 0.02 TEH TEC 14 33 DSI 0.60 104 P1 O1H 0.03 STH TEC 14 33 DSI 0.50 146 P1 02H 0.00 STH TEC 14 34 SAI 0.16 91 6

TSH 3.31 0.28 TSH TSH 14 35 DSI 0.84

.107 P1 01H

-0.03 STH TEC 14 35 DSI 0.69 82 P1 02H 0.05 STH TEC 14 37 DSI 0.16 15 P1 01H 0.07 TEH TEC 14 37 SAI 0.25 83 6

TSH 3.57 0.38 TSH TSH 14 37 SAI 0.11 82 6

TSH 3.39 0.38 TSH TSH 14 37 SAI 0.20 74 6

TSH 2.88 0.36 TSH TSH 14 46 DSI 0.99 81 P1 01H

-0.09 STH TEC 14 46 DSI 0.65 83 P1 02H 0.14 STH TEC 14 50 DSI 0.49 40 P1 02H 0.00 TEH TEC 14 51 DSI 0.48 127 P1 01H 0.06 STH TEC 14 55 DSI 0.54 27 P1 02H 0.05 TEH TEC 14 64 DSI 1.49 121 P1 01H -0.05 TEH TEC 14 64 MAI 0.48 93 6

01H

-0.02 0.33 01H 01H 14 65 DSI 1.10 130 P1 01H

-0.05 TEH TEC 14 65 DSI 0.88 118 P1 02H 0.07 TEH TEC 14 71 DSI 0.88 90 P1 01H 0.10 TEH TEC 14 71 DSI 0.61 39 P1 02H 0.07 TEH TEC 14 71 PVN 0.31 46 6

TSH 7.10 TSH TSH 14 73 DSI 0.55 144 P1 01H

-0.17 TEH TEC 14 73 SAI 0.39 91 6

01H 0.02 0.46 01H 01H 14 73 PVN 0.30 40 6

TSH 6.18 TSH TSH 14 77 DSI 0.60 74 P1 01H 0.00 TEH TEC 14 79 DSI 0.62 68 P1 01H 0.00 TEH TEC 14 80 DSI 0.58 49 P1 02H

-0.02 TEH TEC 14 80 PCT 1.30 0

19 P2 AV1 0.00 TEH TEC 14 81 DSI 1.25 103 P1 01H 0.00 TEH TEC 14 81 DSI 1.41 105 P1 02H

-0.07 TEH TEC 14 82 DSI 0.43 45 P1 01H 0.07 TEH TEC 14 82 DSI 0.21 104 P1 03H 0.10 TEH TEC 14 84 DSI 0.69 140 P1 01H

-0.15 TEH TEC 14 84 SAI 0.24 92 6

01H 0.04 0.21 01H 01H 14 84 DSI 0.91 82 P1 02H 0.00 TEH TEC 14 87 DSI 0.25 88 P1 01H 0.10 TEH TEC 14 87 DSI 0.58 32 P1 02H

-0.07 TEH TEC 14 90 DSI 0.66 71 P1 01H 0.05 TEH TEC 14 90 DSI 0.73 74 P1 04H

-0.02 TEH TEC

Beaver Valley Unit #1 1 R1 5 S/G Examination Results 1RC-E-1B (TUBES WITH INDICATIONS)

Page 18 of 41 Row Col 14 92 14 92 15 3

15 5

15 6

15 6

15 9

15 9

15 10 15 10 15 10 15 11 15 11 15 11 15 11 15 12 15 12 15 12 15 12 15 12 15 12 15 13 15 13 15 15 15 15 15 15 15 16 15 16 15 16 15 17 15 25 15 25 15 29 15 31 15 31 15 31 15 32 15 35 15 35 15 36 15 39 15 39 15 39 15 45 15 47 15 48 15 48 15 48 15 48 15 49 15 49 Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To PCT 0.86 137 3

P1 02C -0.15 TEH TEC VOL 0.38 89 6

02C

-0.15 02C 02C PCT 1.41 114 30 P1 01C -0.05 TEH TEC DSI 0.52 67 P1 01H 0.03 TEH TEC PCT 0.84 139 0

P1 01C 0.10 TEH TEC PCT 0.55 116 29 P1 01C

-0.11 TEH TEC PVN 5.27 10 1

01C 45.14 TEH TEC DSI 0.43 52 P1 01H 0.10 TEH TEC DSI 0.81 39 P1 01H

-0.05 TEH TEC SAI 0.93 99 6

01H 0.00 0.47 01H 01H DSI 0.69 95 P1 02H 0.00 TEH TEC DSI 1.08 94 P1 01H

-0.10 TEH TEC MAI 0.55 101 6

01H

-0.18 0.40 01H 01H DSI 0.50 74 P1 02H 0.20 TEH TEC MAI 0.28 98 6

02H 0.09 0.27 01H 02H DSI 1.61 120 P1 01H 0.10 TEH TEC DSI 1.52 79 P1 02H

-0.07 TEH TEC MAI 0.54 96 6

02H 0.00 0.49 02H 03H DS1 0.99 98 P1 03H

-0.07 TEH TEC MAI 0.26 99 6

03H

-0.02 0.41 02H 03H DSI 0.57 50 P1 05H 0.02 TEH TEC SPR 1.51 118 P1 02H 0.00 TEH TEC SAI 0.22 84 6

02H

-0.13 0.23 02H 02H SPR 1.71 41 P1 02H 0.00 TEH TEC DSI 1.63 35 P1 02H 0.00 TEH TEC MAI 0.30 86 6

02H

-0.02 0.37 02H 02H DSI 1.20 99 P1 01H 0.10 TEH TEC PVN 5.41 13 1

02C 14.74 TEH TEC DSI 0.69 88 P1 02H 0.00 TEH TEC DSI 0.61 41 P1 01H 0.05 TEH TEC DSI 0.84 47 P1 01H 0.00 STH TEC DSI 1.15 30 P1 02H 0.03 STH TEC DSI 0.97 83 P1 02H

-0.10 1SH TEC DSI 0.38 89 P1 01H 0.03 STH TEC DSI 0.32 106 P1 02H 0.05 STH TEC PTP 0.77 84 6

STH 1.03 STH STH DSI 0.72 113 P1 01H 0.05 STH TEC NOI 0.70 122 3

01C 9.26 2SH TEC DSI 0.31 72 P1 03H 0.08 2SH TEC DSI 0.85 98 P1 02H 0.00 1SH TEC DSI 1.31 59 P1 01H 0.05 TEH TEC SAI 0.36 88 6

TSH 3.33 0.69 TSH TSH SAI 0.32 72 6

TSH 2.57 0.28 TSH TSH SAI 0.24 94 6

TSH 0.61 0.46 TSH TSH DSI 0.61 123 P1 01H 0.02 TEH TEC DSI 0.51 109 P1 O1H

-0.12 TEH TEC SAI 0.49 96 6

01H

-0.02 0.54 01H 01H DSI 0.30 125 P1 02H 0.02 TEH TEC SAI 0.46 96 6

02H 0.08 0.49 02H 02H DSI 1.11 88 P1 01H

-0.06 STH TEC DSI 1.49 72 P1 02H 0.06 STH TEC

Beaver Valley Unit #1 1 R15 S/G Examination Results 1 RC-E-1 B (TUBES WITH INDICATIONS)

Page 19 of 41 Row Col 15 49 15 51 15 51 15 52 15 52 15 53 15 54 15 58 15 58 15 58 15 58 15 60 15 60 15 60 15 61 15 63 15 63 15 63 15 64 15 64 15 65 15 65 15 65 15 65 15 70 15 70 15 70 15 71 15 72 15 72 15 78 15 81 15 85 15 89 15 91 15 91 16 5

16 6

16 7

16 8

16 8

16 8

16 10 16 10 16 10 16 11 16 17 16 19 16 19 16 20 16 21 Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To DSI 0.77 57 P1 03H 0.03 STH TEC DSI 0.53 78 P1 01H 0.03 STH TEC PTP 0.88 57 6

STH 1.03 STH STH DSI 0.50 49 P1 01H

-0.02 TEH TEC DSI 0.40 45 P1 02H 0.10 TEH TEC SAI 0.34 83 6

TSH 0.40 0.47 TSH TSH DSI 0.25 83 P1 02H 0.02 TEH TEC DSI 0.59 66 P1 01H 0.02 TEH TEC DSI 0.83 62 P1 02H

-0.02 TEH TEC DSI 0.83 51 P1 03H

-0.05 TEH TEC DSI 0.37 123 P1 04H

-0.15 TEH TEC DSI 0.64 114 P1 01H

-0.10 TEH TEC SAI 0.13 104 6

01H

-0.02 0.19 011H 01H DSI 0.25 83 P1 03H 0.02 TEH TEC DSI 1.00 81 P1 01H 0.12 TEH TEC DSI 0.40 49 P1 01H 0.02 TEH TEC DSI 0.88 77 P1 02H

-0.05 TEH TEC SAI 0.24 113 6

02H

-0.11 0.17 02H 02H DSI 0.89 40 P1 01H 0.00 TEH TEC MAI 0.22 81 6

01H

-0.08 0.31 011H 01H SPR 1.54 38 P1 02H 0.00 TEH TEC DSI 1.27 27 P1 02H 0.05 TEH TEC SAI 0.37 95 6

02H

-0.11 0.31 02H 02H PVN 0.24 43 6

TSH 0.22 TSH TSH DSI 0.68 33 P1 01H

-0.03 TEC TEH DSI 0.59 29 P1 01H 0.00 TEH TEC SAI 0.20 96 6

01H 0.00 0.26 011H 01H DNI 0.26 99 5

AV3 2.85 TEH TEC DSI 0.43 93 P1 01H 0.07 TEH TEC NOI 0.48 106 3

05H 16.23 TEH TEC DSI 0.51 97 P1 01H 0.05 TEH TEC DSI 0.53 28 P1 01H 0.05 TEH TEC DSI 0.48 43 P1 04H 0.05 TEH TEC DSI 0.30 25 P1 03H 0.00 TEH TEC PCT 1.46 124 16 P1 01C 0.12 TEH TEC DSI 0.43 84 P1 02H 0.07 TEH TEC PCT 1.99 109 33 P1 01C 0.00 TEH TEC PCT 1.09 113 33 P1 01C 0.00 TEH TEC DSI 1.04 68 P1 01H 0.10 TEH TEC DSI 0.35 139 P1 01H 0.03 TEH TEC MAI 0.41 85 6

01H 0.08 0.71 01H 01H DSI 0.46 91 P1 02H 0.11 TEH TEC SPR 1.65 74 P1 02H 0.00 TEH TEC DSI 1.09 88 P1 02H

-0.16 TEH TEC MAI 0.54 87 6

02H

-0.12 0.37 02H 02H DSI 0.80 71 P1 01H 0.08 TEH TEC DSI 0.85 52 P1 01H 0.02 TEH TEC DSI 1.90 110 P1 01H

-0.05 TEH TEC DSI 0.64 99 P1 02H

-0.19 TEH TEC DSI 0.85 82 P1 02H

-0.02 TEH TEC DSI 0.89 58 P1 01H 0.02 TEH TEC

Beaver Valley Unit #1 1 R1 5 S/G Examination Results 1 RC-E-1 B (TUBES WITH INDICATIONS)

Page 20 of 41 Row Col 16 21 16 21 16 22 16 23 16 24 16 24 16 24 16 25 16 25 16 25 16 28 16 33 16 33 16 33 16 35 16 35 16 35 16 35 16 36 16 38 16 39 16 40 16 45 16 45 16 46 16 47 16 51 16 51 16 51 16 51 16 51 16 51 16 53 16 56 16 56 16 56 16 56 16 56 16 57 16 58 16 58 16 58 16 58 16 59 16 59 16 59 16 59 16 59 16 59 16 60 16 64 Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To MAI 0.42 113 6

01H 0.04 0.23 01H 01H DSI 0.83 71 P1 02H 0.05 TEH TEC SAI 0.47 11 6

TSH

-0.59 0.27 TSH TSH DSI 0.59 37 P1 01H 0.07 TEH TEC DSI 0.93 55 P1 01H 0.00 TEH TEC MAI 0.39 98 6

01H 0.03 0.28 01H 01H DSI 0.31 44 P1 02H 0.05 TEH TEC SPR 1.70 45 P1 01H 0.00 TEH TEC DSI 1.17 22 P1 O1H 0.00 TEH TEC MAI 0.31 106 6

01H 0.02 0.33 01H 01H DSI 0.78 51 P1 01H 0.00 STH TEC DSI 0.34 127 P1 01H 0.21 STH TEC MAI 1.39 113 2

01H 0.11 0.61 01H 01H DSI 1.16 28 P1 02H 0.10 STH TEC NQI 0.67 117 3

02C 6.21 1SH TEC DSI 1.06 43 P1 02H 0.05 1SH TEC DSI 0.75 37 P1 03H 0.05 1SH TEC PTP 0.58 53 6

STH 1.29 STH STH DSI 0.99 77 P1 02H

-0.07 STH TEC DSI 0.62 63 P1 01H 0.03 STH TEC DSI 0.88 79 P1 01H

-0.05 STH TEC DSI 0.86 63 P1 01H

-0.10 STH TEC DSI 0.52 80 P1 02H 0.05 STH TEC PTP 0.62 69 4

STH 0.71 STH STH DSI 0.45 58 P1 01H 0.00 STH TEC SAI 0.22 71 6

TSH 0.33 0.31 TSH TSH DSI 1.42 94 P1 01H 0.02 TEH TEC DSI 1.12 94 P1 02H 0.20 TEH TEC SAI 0.46 103 6

02H

-0.05 0.54 02H 02H DSI 1.34 90 P1 04H 0.07 TEH TEC NOI 0.73 111 3

06C 34.50 TEH TEC MAI 0.31 81 6

TSH 0.23 0.31 TSH TSH DSI 0.14 86 P1 01H 0.02 TEH TEC DSI 0.62 38 P1 01H

-0.05 TEH TEC SAI 0.16 100 6

01H 0.03 0.14 O1H O1H DSI 0.56 73 P1 02H 0.07 TEH TEC DSI 0.62 45 P1 03H 0.12 TEH TEC SAI 0.24 107 6

03H 0.03 0.19 03H 03H DSI 0.40 116 P1 O1H 0.10 TEH TEC DSI 0.50 79 P1 O1H 0.02 TEH TEC DSI 0.41 116 P1 02H

-0.05 TEH TEC DSI 0.68 46 P1 03H

-0.05 TEH TEC SAI 0.29 104 6

03H

-0.15 0.31 03H 03H DSI 1.02 110 P1 01H 0.02 TEH TEC DSI 0.96 98 P1 02H 0.32 TEH TEC SAI 0.21 128 6

02H 0.14 0.17 02H 02H DSI 0.85 91 P1 03H

-0.05 TEH TEC SAI 0.62 99 6

03H

-0.01 0.40 03H 03H DSI 0.40 67 P1 04H 0.02 TEH TEC DSI 0.94 69 P1 01H 0.10 TEH TEC DSI 0.35 121 P1 01H 0.02 TEH TEC

Beaver Valley Unit #1 Page 21 of 41 1 R1 5 S/G Examination Results 1 RC-E-1 B (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 16 66 DSI 0.98 83 P1 01H

-0.07 TEH TEC 16 67 DSI 0.52 52 P1 01H 0.05 TEH TEC 16 67 DSI 0.42 60 P1 02H

-0.02 TEH TEC 16 69 DSI 0.48 40 P1 04H 0.05 TEH TEC 16 75 SPR 1.59 31 P1 01H 0.00 TEH TEC 16 75 DSI 1.03 146 P1 01H 0.12 TEH TEC 16 75 MAI 0.51 88 6

01H 0.06 0.30 01H 01H 16 78 DSI 1.31 47 P1 01H 0.05 TEH TEC 16 78 SAI 0.64 78 6

01H 0.00 0.31 01H 01H 16 79 DSI 0.96 159 P1 01H 0.05 TEH TEC 16 80 DSI 0.38 54 P1 01H 0.10 TEH TEC 16 80 DSI 0.26 46 P1 06H 0.03 TEH TEC 16 82 DSI 0.77 70 P1 01H 0.02 TEH TEC 16 82 SAI 0.33 96 6

01H

-0.06 0.29 01H 01H 16 82 DSI 0.61 92 P1 02H 0.29 TEH TEC 16 82 SAI 0.19 108 6

02H 0.10 0.18 02H 02H 16 82 DSI 0.17 86 P1 06H 0.00 TEH TEC 16 83 DSI 0.25 50 P1 01H 0.02 TEH TEC 16 88 PCT 0.71 139 0

P1 01C

-0.25 TEH TEC 16 88 DSI 0.73 38 P1 03H 0.07 TEH TEC 16 88 MAI 0.24 98 6

03H 0.00 0.29 03H 03H 16 88 PVN 3.76 55 P2 03H 0.93 03H 03H 16 88 MAI 0.23 102 6

03H 0.05 0.39 03H 03H 16 88 PVN 0.36 41 6

03H 0.93 03H 03H 16 89 PCT 0.34 145 0

P1 01C

-0.07 TEH TEC 16 89 PCT 0.44 130 6

P1 02C 0.20 TEH TEC 16 90 PCT 0.25 121 23 P1 02C 0.12 TEH TEC 16 90 VOL 0.53 124 6

02C -0.12 02C 02C 17 4

PCT 1.89 112 29 P1 01C -0.08 TEH TEC 17 6

DSI 0.72 56 P1 01H 0.00 TEH TEC 17 7

DSI 0.85 100 P1 02H

-0.10 TEH TEC 17 7

DSI 0.64 54 P1 03H 0.00 TEH TEC 17 7

SAI 0.31 99 6

03H 0.04 0.30 03H 03H 17 10 DSI 0.78 55 P1 01H 0.03 TEH TEC 17 10 MAI 0.39 107 6

01H

-0.01 0.32 01H 01H 17 10 DSI 0.86 40 P1 02H 0.00 TEH TEC 17 10 MAI 0.16 111 6

02H 0.05 0.15 02H 02H 17 13 DSI 1.26 65 P1 02H 0.13 TEH TEC 17 14 NQI 0.28 113 3

01C 47.88 1SH TEC 17 14 NQI 0.34 126 3

02C 12.69 1SH TEC 17 14 NQI 0.63 119 3

02C 15.16 1SH TEC 17 14 DSI 1.29 51 P1 02H

-0.03 1SH TEC 17 14 NQI 0.71 133 3

03C 22.13 1SH TEC 17 16 DSI 1.75 109 P1 02H

-0.20 TEH TEC 17 16 SPR 1.52 93 P1 03H 0.00 TEH TEC 17 16 SAI 0.30 87 6

03H

-0.17 0.48 03H 03H 17 16 DSI 0.80 66 P1 05H 0.00 TEH TEC 17 16 SAI 0.24 103 6

05H

-0.09 0.28 05H 05H 17 16 DSI 0.54 79 P1 06H 0.06 TEH TEC 17 17 DSI 0.60 38 P1 02H 0.02 TEH TEC 17 17 SAI 0.29 88 6

02H

-0.15 0.54 02H 02H

Beaver Valley Unit #1 Page 22 of 41 1 R1 5 S/G Examination Results 1RC-E-1B (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan, Loc Inch1 Cr-Length Cr-Angle From To 17 23 DSI 0.65 57 P1 01H 0.12 TEH TEC 17 23 SAI 0.63 94 6

01H 0.00 0.34 01H 01H 17 24 DSI 0.71 83 P1 01H

-0.02 TEH TEC 17 24 DSI 0.66 70 P1 02H 0.02 TEH TEC 17 28 DSI 0.72 43 P1 01H 0.00 STH TEC 17 28 DSI 0.36 25 P1 02H 0.08 STH TEC 17 30 DSI 0.84 79 P1 01H 0.07 STH TEC 17 32 PTP 0.19 38 6

STH 1.14 STH STH 17 38 DSI 0.59 122 P1 01H 0.20 STH TEC 17 38 NOI 0.65 119 3

TSC 44.68 STH TEC 17 38 NOI 0.31 147 3

TSC 22.84 STH TEC 17 39 NQI 0.34 138 3

TSC 35.10 1SH TEC 17 40 PTP 0.95 33 5

STH 0.99 STH STH 17 43 SPR 1.93 145 P1 02H 0.00 1SH TEC 17 43 DSI 1.37 143 P1 02H 0.27 1SH TEC 17 43 MAI 0.92 114 2

02H

-0.03 0.53 02H 02H 17 43 DSI 0.91 113 P1 03H 0.37 1SH TEC 17 43 MAI 1.48 90 2

03H

-0.24 0.73 03H 03H 17 43 DSI 1.33 146 P1 04H

-0.17 1SH TEC 17 43 MAI 0.80 77 2

04H

-0.23 0.70 04H 04H 17 44 DSI 1.13 118 P1 01H 0.14 STH TEC 17 44 DSI 1.02 84 P1 02H 0.20 STH TEC 17 44 PTP 0.47 43 6

STH 1.46 STH STH 17 48 DSI 0.52 75 P1 02H 0.05 TSH TEC 17 48 DSI 0.56 66 P1 02H 0.05 TEH TEC 17 48 SAI 0.66 97 6

02H 0.00 0.40 02H 02H 17 55 DSI 0.80 66 P1 01H 0.07 TEH TEC 17 55 DSI 1.06 106 P1 02H

-0.15 TEH TEC 17 56 DSI 0.84 102 P1 01H 0.12 TEH TEC 17 56 DSI 0.96 91 P1 02H

-0.05 TEH TEC 17 56 SAI 0.49 104 6

02H

-0.11 0.38 02H 02H 17 56 DSI 0.43 60 P1 03H

-0.02 TEH TEC 17 58 DSI 0.50 92 P1 02H

-0.07 TEH TEC 17 60 DSI 0.32 129 P1 03H 0.10 TEH TEC 17 61 PVN 0.55 73 2

07H 22.50 07C 07H 17 63 PVN 0.15 34 6

TSH 0.07 TSH TSH 17 63 PVN 0.11 80 6

TSH

-5.02 TSH TSH 17 64 DSI 0.56 62 P1 O1H 0.05 TEH TEC 17 64 PVN 0.24 120 2

AV2 3.06 07C 07H 17 66 DSI 1.30 114 P1 01H

-0.02 TEH TEC 17 67 DSI 1.42 91 P1 02H

-0.10 TEH TEC 17 67 SAI 0.74 97 6

02H

-0.07 0.45 02H 02H 17 68 DSI 0.69 124 P1 01H 0.12 TEH TEC 17 69 DSI 0.58 127 P1 01H

-0.17 TEH TEC 17 70 DSI 0.36 133 P1 01H 0.12 TEH TEC 17 70 DSI 0.61 48 P1 02H

-0.02 TEH TEC 17 70 DSI 0.85 85 P1 03H

-0.07 TEH TEC 17 71 DSI 0.79 41 P1 01H 0.07 TEH TEC 17 71 MAI 0.24 111 6

01H

-0.01 0.36 01H 01H 17 71 NQI 0.70 49 3

AV4 20.15 TEH TEC 17 72 DSI 0.45 27 P1 03H 0.05 TEH TEC

Beaver Valley Unit #1 Page 23 of 41 1 R1 5 S/G Examination Results 1 RC-E-1 B (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 17 73 DSI 1.14 64 P1 02H 0.02 TEH TEC 17 74 DSI 1.91 116 P1 01H

-0.12 TEH TEC 17 74 DSI 0.62 66 P1 02H

-0.10 TEH TEC 17 74 NOI 0.50 110 3

04H 19.17 TEH TEC 17 74 NOI 0.49 106 3

04H 19.05 TEH TEC 17 74 DSI 0.46 141 P1 04H

-0.22 TEH TEC 17 74 SAI 0.17 77 6

04H 0.18 0.31 04H 05H 17 75 PVN 0.77 29 6

TSH 6.55 TSH TSH 17 80 DSI 1.24 90 P1 01H

-0.02 TEH TEC 17 80 DSI 0.67 109 P1 02H 0.02 TEH TEC 17 80 DSI 0.17 67 P1 06H 0.08 TEH TEC 17 82 DSI 0.29 122 P1 01H 0.02 TEH TEC 17 84 DSI 0.59 43 P1 02H 0.00 TEH TEC 17 88 DSI 0.30 63 P1 02H 0.05 TEH TEC 17 88 SAI 0.27 102 6

02H

-0.04 0.31 02H 02H 18 5

DSI 0.37 129 P1 O1H 0.08 TEH TEC 18 5

SAI 0.17 99 6

O1H

-0.03 0.18 O1H 02H 18 5

DNG 6.39 178 1

01H 3.42 TEH TEC 18 5

SAI 0.76 18 6

O1H 3.22 0.49 O1H 02H 18 8

DSI 0.31 100 P1 01H 0.10 TEH TEC 18 10 DSI 0.55 68 P1 02H 0.03 TEH TEC 18 10 DSI 0.74 51 P1 03H 0.11 TEH TEC 18 11 DSI 0.87 61 P1 01H 0.03 TEH TEC 18 12 DSI 1.32 95 P1 01H 0.08 TEH TEC 18 12 DSI 1.10 79 P1 02H 0.13 TEH TEC 18 12 DSI 0.44 87 P1 03H 0.11 TEH TEC 18 12 MAI 0.29 91 6

03H 0.01 0.71 03H 03H 18 15 DSI 1.20 98 P1 01H 0.03 TEH TEC 18 15 SPR 1.60 84 P1 01H 0.00 TEH TEC 18 15 MAI 0.40 88 6

01H 0.06 0.28 01H 01H 18 19 DSI 0.56 131 P1 02H

-0.19 TEH TEC 18 19 SAI 0.23 103 6

02H 0.01 0.68 02H 02H 18 20 DSI 0.55 125 P1 01H 0.00 TEH TEC 18 21 DSI 1.02 122 P1 O1H

-0.12 TEH TEC 18 21 DSI 1.51 77 P1 02H 0.10 TEH TEC 18 21 MAI 0.62 86 6

02H

-0.05 0.43 02H 02H 18 21 DSI 0.25 90 P1 07C

-0.07 TEH TEC 18 23 DSI 0.66 117 P1 01H 0.10 TEH TEC 18 23 DSI 0.38 75 P1 02H 0.07 TEH TEC 18 23 DSI 0.36 35 P1 03H 0.10 TEH TEC 18 24 DSI 0.62 61 P1 01H 0.02 TEH TEC 18 33 DSI 0.96 70 P1 01H 0.07 STH TEC 18 35 DSI 0.70 47 P1 02H

-0.05 TEH TEC 18 35 SAI 0.19 82 6

02H 0.00 0.20 02H 02H 18 37 DSI 0.80 44 P1 01H

-0.02 TEH TEC 18 37 SAI 0.27 113 6

01H

-0.08 0.27 01H 01H 18 40 DSI 0.84 79 P1 02H 0.02 1SH TEC 18 40 PTP 0.88 57 6

STH 1.00 STH STH 18 41 DSI 0.47 79 P1 01H 0.00 STH TEC 18 48 DSI 1.71 95 P1 01H 0.10 TEH TEC 18 48 DSI 1.10 114 P1 02H

-0.12 TEH TEC

Beaver Valley Unit #1 Page 24 of 41 1 R1 5 S/G Examination Results 1RC-E-1B (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 18 49 DSI 0.40 64 P1 02H 0.02 TEH TEC 18 49 PCT 1.01 57 16 P2 AV2

-0.07 TEH TEC 18 49 WAR 0.27 148 2

AV2 0.00 07C 07H 18 50 DSI 0.81 56 P1 01H 0.10 TEH TEC 18 51 DSI 0.50 50 P1 02H 0.05 TEH TEC 18 53 DSI 0.99 89 P1 01H 0.19 TEH TEC 18 53 DSI 1.23 105 P1 04H

-0.10 TEH TEC 18 61 DSI 0.67 74 P1 -011H 0.02 TEH TEC 18 61 SAI 0.63 91 6

011H 0.04 0.36 01H 01H 18 62 DSI 1.28 109 P1 01H 0.02 TEH TEC 18 62 DSI 0.48 107 P1 03H 0.05 TEH TEC 18 63 DSI 1.53 94 P1 01H 0.00 TEH TEC 18 63 DSI 0.67 42 P1 03H 0.00 TEH TEC 18 63 SAI 0.49 101 6

03H

-0.04 0.72 03H 03H 18 65 DS1 0.90 61 P1 01H 0.02 TEH TEC 18 65 DSI 1.15 40 P1 02H 0.00 TEH TEC 18 65 SAI 0.31 99 6

02H

-0.07 0.31 02H 02H 18 65 PCT 2.06 27 25 P2 AV1

-0.47 TEH TEC 18 65 WAR 0.45 130 2

AV1

-0.47 07C 07H 18 69 PVN 0.87 45 P2 TSH

-0.06 TSH TSH 18 70 DSI 0.66 82 P1 01H 0.12 TEH TEC 18 70 MAI 0.60 86 6

01H 0.03 0.40 O1H 011H 18 71 DSI 0.28 107 P1 02H 0.05 TEH TEC 18 74 DSI 0.71 94 P1 02H 0.02 TEH TEC 18 75 DSI 0.38 23 P1 01H 0.05 TEH TEC 18 79 DSI 0.39 51 P1 01H 0.00 TEH TEC 18 81 PVN 1.15 45 6

TSH 2.03 TSH TSH 18 83 DSI 0.39 78 P1 011H 0.07 TEH TEC 18 85 DSI 0.43 43 P1 04H 0.05 TEH TEC 18 88 PCT 0.30 127 15 P1 01C

-0.22 TEH TEC 18 89 PCT 0.58 111 34 P1 02C

-0.10 TEH TEC 18 90 DSI 0.57 29 P1 03H

-0.02 TEH TEC 19 10 PCT 0.56 146 0

P1 01C

-0.21 TEH TEC 19 10 DSI 0.93 84 P1 01H 0.16 TEH TEC 19 10 DSI 0.89 138 P1 02H

-0.16 TEH TEC 19 10 DSI 0.80 135 P1 04H 0.11 TEH TEC 19 11 DSI 0.73 115 P1 O1H

-0.13 TEH TEC 19 15 DSI 0.78 37 P1 01H 0.00 TEH TEC 19 15 MAI 0.42 102 6

01H

-0.05 0.30 01H 01H 19 19 DSI 1.04 80 P1 01H 0.00 TEH TEC 19 20 DSI 0.37 59 P1 01H 0.00 TEH TEC 19 22 PVN 0.26 33 2

AV2 4.14 07C 07H 19 24 DSI 0.55 93 P1 011H 0.07 TEH TEC 19 28 PCT 1.44 0

21 P2 AV1 0.00 STH TEC 19 28 WAR 0.40 131 2

AV1 0.00 07C 07H 19 28 PCT 1.04 0

17 P2 AV3 0.00 STH TEC 19 28 WAR 0.32 130 2

AV3 0.00 07C 07H 19 28 WAR 0.35 322 2

AV4

-0.01 07C 07H 19 29 DSI 0.54 52 P1 01H

-0.02 TEH TEC 19 31 DSI 0.63 61 P1 02H 0.02 TEH TEC 19 34 DSI 0.80 45 P1 011H 0.05 STH TEC

Beaver Valley Unit #1 1 R1 5 S/G Examination Results 1 RC-E-1 B (TUBES WITH INDICATIONS)

Page 25 of 41 Row Col 19 38 19 40 19 40 19 40 19 41 19 42 19 44 19 47 19 49 19 53 19 53 19 56 19 56 19 56 19 58 19 62 19 64 19 69 19 75 19 75 19 76 19 77 19 77 19 82 19 82 19 85 19 86 19 87 19 87 19 87 19 87 19 89 19 89 19 89 19 90 20 6

20 7

20 7

20 8

20 9

20 9

20 11 20 11 20 14 20 15 20 15 20 21 20 23 20 25 20 25 20 25 Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To DSI 0.58 89 P1 01H

-0.03 STH TEC NOI 0.24 117 3

06C 12.82 1SH TEC NQI 0.30 113 3

06C 34.48 1SH TEC NQI 0.37 116 3

TSC 10.00 1SH TEC PTP 0.47 97 6

STH 1.02 STH STH DSI 0.38 75 P1 01H 0.03 STH TEC DNI 1.20 108 5

AV4 11.31 TEH TEC DSI 1.09 89 P1 02H

-0.17 TEH TEC DSI 1.36 96 P1 01H 0.05 TEH TEC DSI 0.77 33 P1 02H 0.10 TEH TEC SAI 0.38 101 6

02H 0.00 0.36 02H 02H DSI 1.56 84 P1 01H 0.05 TEH TEC DSI 1.12 66 P1 02H 0.00 TEH TEC DSI 0.72 85 P1 03H

-0.05 TEH TEC DSI 0.97 80 P1 02H

-0.02 TEH TEC DSI 0.88 88 P1 011H 0.02 TEH TEC DSI 0.77 60 P1 01H

-0.07 TEH TEC DSI 0.37 45 P1 04H 0.02 TEH TEC PVN 4.37 41 P2 AV4 8.59 07C 07H PVN 1.76 29 P2 AV4 8.59 07C 07H DSI 0.58 46 P1 011H 0.10 TEH TEC DSI 0.93 53 P1 02H 0.10 TEH TEC MAI 0.37 107 6

02H 0.02 0.33 02H 02H DSI 2.26 68 P1 03H

-0.02 TEH TEC MAI 0.46 82 6

03H

-0.07 0.43 03H 03H DSI 0.92 51 P1 01H 0.05 TEH TEC DSI 0.70 126 P1 04H 0.20 TEH TEC DSI 0.74 76 P1 02H 0.25 TEH TEC SAI 0.18 106 6

02H 0.00 0.31 02H 02H DSI 0.63 41 P1 04H 0.05 TEH TEC MAI 0.18 77 6

04H

-0.02 0.26 04H 04H DSI 0.74 33 P1 02H 0.00 TEH TEC PVN 1.57 67 6

02H 0.00 02H 02H SAI 0.51 103 6

02H 0.01 0.51 02H 02H PCT 0.42 145 0

P1 02C 0.17 TEH TEC PCT 0.73 146 0

P1 02C 0.21 TEH TEC DSI 1.09 114 P1 01H 0.08 TEH TEC MAI 0.57 98 6

01H 0.00 0.40 01H 01H DSI 0.57 46 P1 02H 0.00 TEH TEC DSI 0.37 89 P1 01H 0.08 TEH TEC DSI 0.26 111 P1 02H 0.05 TEH TEC DSI 1.90 96 P1 01H 0.00 TEH TEC DSI 0.85 69 P1 03H 0.00 TEH TEC SAI 0.72 16 6

TSH

-4.68 0.25 TSH TSH DSI 0.61 64 P1 01H 0.05 TEH TEC DSI 0.75 102 P1 02H

-0.10 TEH TEC DSI 0.63 103 P1 01H

-0.05 TEH TEC DSI 0.58 109 P1 02H 0.07 TEH TEC DSI 1.68 84 P1 01H 0.02 TEH TEC DSI 1.07 81 P1 02H 0.02 TEH TEC DSI 0.98 122 P1 03H 0.00 TEH TEC

Beaver Valley Unit #1 Page 26 of 41 1 R1 5 S/G Examination Results 1RC-E-1B (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 20 27 DSI 0.40 86 P1 01H 0.02 TEH TEC 20 30 DSI 0.54 100 P1 01H 0.05 TEH TEC 20 31 DSI 0.79 82 P1 01H 0.00 TEH TEC 20 34 PTP 0.60 72 6

STH 1.06 STH STH 20 35 DSI 0.55 55 P1 01 H

-0.02 TEH TEC 20 37 DSI 0.60 65 P1 01H 0.05 TEH TEC 20 37 DSI 0.68 73 P1 02H 0.05 TEH TEC 20 37 SAI 0.57 95 6

02H

-0.05 0.40 02H 02H 20 44 DSI 0.54 49 P1 02H 0.00 TEH TEC 20 47 DSI 0.55 52 P1 01H 0.12 TEH TEC 20 47 DSI 0.32 49 P1 02H 0.10 TEH TEC 20 48 DSI 1.00 76 P1 01H 0.02 TEH TEC 20 48 MAI 0.32 97 6

01H

-0.04 0.46 01H 01H 20 48 DSI 0.63 41 P1 02H 0.02 TEH TEC 20 48 MAI 0.36 112 6

02H 0.00 0.39 02H 02H 20 48 MAI 0.35 107 6

02H

-0.06 0.44 02H 02H 20 49 DSI 1.63 96 P1 01 H 0.07 TEH TEC 20 49 DSI 0.58 106 P1 02H

-0.17 TEH TEC 20 51 DSI 1.17 84 P1 01H 0.07 TEH TEC 20 52 DSI 0.34 58 P1 01H 0.10 TEH TEC 20 52 DSI 0.69 26 P1 03H 0.05 TEH TEC 20 52 SAI 0.38 115 6

03H 0.05 0.43 03H 03H 20 54 DSI 0.42 23 P1 02H 0.05 TEH TEC 20 54 MAI 0.26 105 6

02H 0.02 0.43 02H 02H 20 57 DSI 0.68 96 P1 01H 0.05 TEH TEC 20 58 DSI 2.07 100 P1 01H

-0.05 TEH TEC 20 58 SAI 0.91 98 6

01H 0.10 0.38 01H 01H 20 58 DSI 0.82 148 P1 02H 0.17 TEH TEC 20 58 DSI 0.65 92 P1 03H

-0.02 TEH TEC 20 59 DSI 0.21 138 P1 01H 0.07 TEH TEC 20 64 WAR 0.35 131 2

AV2

-0.40 07C 07H 20 64 WAR 0.28 131 2

AV4 0.00 07C 07H 20 66 DSI 0.40 68 P1 02H 0.02 TEH TEC 20 69 DSI 1.02 87 P1 02H 0.07 TEH TEC 20 69 DSI 0.66 130 P1 05H

-0.05 TEH TEC 20 77 DSI 0.30 80 P1 01H 0.00 TEH TEC 20 78 DSI 0.26 49 P1 01H 0.10 TEH TEC 20 81 DSI 0.20 21 P1 05H 0.05 TEH TEC 20 82 DSI 0.51 75 P1 011H 0.05 TEH TEC 20 85 DSI 0.67 53 P1 01H 0.02 TEH TEC 20 87 PCT 0.44 144 0

P1 02C

-0.15 TEH TEC 20 87 DSI 0.45 69 P1 02H 0.12 TEH TEC 20 89 POT 1.02 139 0

P1 01C

-0.17 TEH TEC 21 6

POT 1.25 138 0

P1 01C

-0.16 TEH TEC 21 6

VOL 0.73 107 6

01C

-0.15 01C 01C 21 9

PCT 0.49 133 0

P1 01C

-0.08 TEH TEC 21 9

VOL 0.31 100 6

010

-0.08 01C 01C 21 9

DSI 0.32 73 P1 01H 0.00 TEH TEC 21 11 DSI 0.50 58 P1 01H 0.05 TEH TEC 21 11 SAI 0.22 94 6

011H

-0.11 0.23 01H 01H 21 12 DSI 0.85 69 P1 01H 0.05 TEH TEC

Beaver Valley Unit #1 Page 27 of 41 1 R1 5 S/G Examination Results 1 RC-E-1 B (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 21 12 MAI 0.41 109 6

01H 0.01 0.32 01H 01H 21 13 DSI 0.85 90 P1 02H

-0.08 TEH TEC 21 14 DSI 1.05 49 P1 02H 0.12 TEH TEC 21 14 MAI 0.47 98 6

02H 0.09 0.35 02H 02H 21 17 DSI 0.84 131 P1 O1H

-0.19 TEH TEC 21 17 SAI 0.52 99 6

O1H

-0.09 0.40 O1H O1H 21 18 DSI 0.87 84 P1 O1H 0.02 TEH TEC 21 18 DSI 0.88 63 P1 02H 0.00 TEH TEC 21 19 DSI 0.69 54 P1 02H

-0.02 TEH TEC 21 20 DSI 1.14 102 P1 O1H 0.05 TEH TEC 21 21 DSI 1.37 54 P1 O1H 0.00 TEH TEC 21 21 MAI 0.38 101 6

O1H

-0.06 0.28 O1H O1H 21 21 DSI 0.59 36 P1 02H 0.00 TEH TEC 21 21 MAI 0.17 97 6

02H

-0.14 0.32 02H 02H 21 22 DSI 1.08 46 P1 O1H

-0.05 TEH TEC 21 22 MAI 0.29 103 6

O1H

-0.04 0.53 O1H O1H 21 22 DSI 1.09 26 P1 02H 0.00 TEH TEC 21 22 MAI 0.19 94 6

02H 0.02 0.45 02H 02H 21 24 DSI 0.95 50 P1 01H

-0.02 TEH TEC 21 24 MAI 0.32 93 6

O1H

-0.04 0.25 O1H O1H 21 25 DSI 1.02 73 P1 O1H 0.00 TEH TEC 21 25 DSI 0.44 58 P1 02H 0.02 TEH TEC 21 25 DSI 0.36 89 P1 05H 0.00 TEH TEC 21 26 PVN 8.11 13 1

O1C 26.21 TEH TEC 21 26 DSI 0.62 80 P1 O1H 0.00 TEH TEC 21 29 DSI 0.90 87 P1 01H

-0.02 TEH TEC 21 29 DSI 0.54 73 P1 02H 0.05 TEH TEC 21 30 DSI 0.63 27 P1 01H 0.07 TEH TEC 21 30 SAI 0.14 110 6

01H 0.06 0.22 01H 01H 21 33 DSI 0.70 52 P1 01H 0.02 TEH TEC 21 33 NOI 0.49 124 3

O1H 11.83 TEH TEC 21 33 MAI 0.33 106 6

O1H 0.10 0.40 01H 02H 21 33 DSI 0.88 43 P1 02H 0.05 TEH TEC 21 33 SAI 0.72 99 6

02H

-0.05 0.50 02H 02H 21 33 SAI 0.64 100 6

02H 0.04 0.50 O1H 02H 21 34 DSI 1.16 59 P1 O1H 0.02 TEH TEC 21 34 DSI 1.05 100 P1 02H 0.20 TEH TEC 21 39 DSI 1.22 88 P1 O1H 0.02 TEH TEC 21 40 DSI 0.87 71 P1 O1H 0.05 TEH TEC 21 40 DSI 0.52 87 P1 02H 0.02 TEH TEC 21 40 DSI 0.42 68 P1 03H 0.10 TEH TEC 21 42 DSI 0.30 42 P1 O1H 0.02 TEH TEC 21 46 DSI 0.84 66 P1 O1H 0.00 TEH TEC 21 47 DSI 0.72 94 P1 O1H

-0.02 TEH TEC 21 47 DSI 0.87 40 P1 02H

-0.05 TEH TEC 21 47 SAI 0.32 105 6

02H 0.01 0.38 02H 02H 21 48 DSI 0.45 50 P1 02H 0.12 TEH TEC 21 49 DSI 1.22 69 P1 O1H 0.05 TEH TEC 21 49 DSI 0.78 57 P1 02H 0.00 TEH TEC 21 49 SAI 0.52 99 6

02H 0.01 0.38 02H 02H 21 51 DSI 0.48 32 P1 O1H 0.02 TEH TEC

Beaver Valley Unit #1 Page 28 of 41 1 R1 5 S/G Examination Results 1 RC-E-1 B (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 21 51 DSI 0.93 70 P1 02H 0.05 TEH TEC 21 51 DSI 1.13 50 P1 03H

-0.02 TEH TEC 21 51 SAI 0.27 102 6

03H

-0.11 0.38 03H 03H 21 53 DSI 0.55 88 P1 01H 0.05 TEH TEC 21 53 DSI 1.10 55 P1 02H 0.00 TEH TEC 21 53 DSI 0.46 37 P1 03H 0.05 TEH TEC 21 55 DSI 0.86 92 P1 01 H

-0.07 TEH TEC 21 56 DSI 0.36 82 P1 01H 0.02 TEH TEC 21 56 DSI 0.41 48 P1 03H 0.05 TEH TEC 21 57 DSI 0.63 56 P1 01H 0.05 TEH TEC 21 57 DSI 0.85 52 P1 02H 0.02 TEH TEC 21 57 DSI 0.33 69 P1 03H 0.00 TEH TEC 21 57 DSI 0.68 128 P1 04H 0.00 TEH TEC 21 58 DSI 0.78 62 P1 01 H 0.05 TEH TEC 21 58 DSI 0.90 46 P1 02H 0.02 TEH TEC 21 58 SAI 0.53 114 6

02H

-0.12 0.33 02H 02H 21 62 DSI 0.49 31 P1 01H 0.10 TEH TEC 21 62 DSI 0.51 33 P1 03H 0.05 TEH TEC 21 66 DSI 0.54 51 P1 01H 0.02 TEH TEC 21 66 MAI 0.30 93 6

01H 0.01 0.42 01H 01H 21 67 DSI 0.36 38 P1 01H 0.00 TEH TEC 21 70 DSI 0.77 39 P1 01H 0.02 TEH TEC 21 70 MAI 0.39 93 6

01H 0.01 0.40 01H 01H 21 80 DSI 0.27 131 P1 01H

-0.15 TEH TEC 21 83 DSI 0.87 68 P1 01H 0.10 TEH TEC 21 83 DSI 0.64 41 P1 02H 0.05 TEH TEC 21 83 SAI 0.22 91 6

02H

-0.03 0.29 02H 02H 21 83 DSI 0.73 38 P1 03H 0.07 TEH TEC 21 83 SAI 0.26 114 6

03H 0.10 0.26 03H 03H 21 84 PVN 1.37 39 2

AV1 1.18 07C 07H 21 84 PVN 0.90 22 2

AV2 6.03 07C 07H 21 87 PCT 1.91 117 26 P1 02C

-0.17 TEH TEC 21 87 VOL 0.70 98 6

02C

-0.17 02C 02C 22 10 DSI 0.75 87 P1 01H 0.08 TEH TEC 22 11 DSI 0.44 107 P1 011H

-0.20 TEH TEC 22 11 DSI 0.65 81 P1 02H 0.08 TEH TEC 22 12 DSI 0.74 54 P1 011H

-0.03 TEH TEC 22 12 SPR 1.51 76 P1 03H 0.00 TEH TEC 22 12 MAI 0.16 105 6

03H

-0.08 0.57 03H 03H 22 15 DSI 1.94 80 P1 01H 0.08 TEH TEC 22 17 DSI 0.82 38 P1 01H 0.05 TEH TEC 22 17 SAI 0.46 94 6

01H 0.00 0.35 01H 01H 22 19 DSI 1.09 56 P1 02H

-0.02 TEH TEC 22 19 MAI 0.29 78 6

02H

-0.05 0.33 02H 02H 22 19 DSI 0.93 51 P1 03H 0.00 TEH TEC 22 20 DSI 0.93 81 P1 01H 0.05 TEH TEC 22 20 DSI 0.80 66 P1 03H 0.05 TEH TEC 22 22 DSI 0.92 95 P1 01H

-0.07 TEH TEC 22 22 SAI 0.86 91 6

01H

-0.05 0.35 01H 011H 22 22 DSI 0.84 53 P1 02H

-0.07 TEH TEC 22 23 DSI 1.39 77 P1 011H 0.02 TEH TEC

Beaver Valley Unit #1 Page 29 of 41 1 R15 S/G Examination Results 1RC-E-1B (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inchl Cr-Length Cr-Angle From To 22 23 DSI 0.88 64 P1 02H 0.07 TEH TEC 22 23 MAI 0.20 127 6

02H 0.03 0.28 02H 02H 22 23 DSI 0.55 30 P1 03H 0.00 TEH TEC 22 23 SAI 0.20 107 6

03H 0.17 0.40 03H 03H 22 28 DSI 0.52 37 P1 01H 0.07 TEH TEC 22 28 MAI 0.40 100 6

01H 0.01 0.48 011H 01H 22 29 DSI 0.63 60 P1 02H 0.02 TEH TEC 22 39 DSI 0.56 79 P1 02H 0.12 TEH TEC 22 40 DSI 0.90 107 P1 01H 0.10 TEH TEC 22 41 DSI 0.41 92 P1 01H

-0.02 TEH TEC 22 42 DSI 1.16 71 P1 01H 0.07 TEH TEC 22 47 DSI 0.72 43 P1 01H 0.02 TEH TEC 22 47 SAI 0.58 102 6

01H 0.00 0.53 01H 01H 22 50 DSI 0.45 65 P1 01H 0.10 TEH TEC 22 50 DSI 0.48 64 P1 02H 0.00 TEH TEC 22 54 DSI 0.68 97 P1 01H

-0.07 TEH TEC 22 54 DSI 0.84 64 P1 02H 0.07 TEH TEC 22 57 DSI 0.40 35 P1 01H 0.05 TEH TEC 22 58 DSI 0.62 19 P1 01H

-0.02 TEH TEC 22 59 DSI 0.65 70 P1 01H 0.00 TEH TEC 22 60 DSI 0.65 95 P1 02H 0.10 TEH TEC 22 62 DSI 0.57 45 P1 02H 0.05 TEH TEC 22 63 NOI 0.30 127 3

05C 25.16 STH TEC 22 63 NOI 0.39 115 3

06C 47.85 STH TEC 22 69 DSI 0.33 51 P1 03H 0.02 TEH TEC 22 70 DSI 1.06 36 P1 02H 0.05 TEH TEC 22 70 SAI 0.32 102 6

02H 0.01 0.36 02H 02H 22 73 DSI 0.47 20 P1 03H 0.02 TEH TEC 22 75 DSI 1.07 94 P1 01H 0.00 TEH TEC 22 75 DSI 1.08 98 P1 02H 0.15 TEH TEC 22 83 DSI 0.88 67 P1 02H 0.02 TEH TEC 22 84 DSI 0.34 96 P1 01H 0.00 TEH TEC 22 85 PCT 0.71 132 0

P1 01C

-0.17 TEH TEC 22 86 PCT 0.89 131 2

P1 01C

-0.15 TEH TEC 22 86 VOL 0.46 109 6

01C

-0.15 01C 01C 22 86 PCT 0.47 132 0

P1 02C 0.00 TEH TEC 22 86 VOL 0.41 104 6

02C 0.00 02C 02C 23 9

PCT 0.45 127 7

P1 01C

-0.05 TEH TEC 23 17 SVI 2.98 18 2

07H 3.03 0.39 62 07C 07H 23 24 DSI 0.25 161 P1 03H 0.10 TEH TEC 23 29 DSI 0.22 66 P1 01H 0.05 TEH TEC 23 38 DSI 0.59 128 P1 03H 0.22 TEH TEC 23 42 DSI 0.65 35 P1 03H 0.05 TEH TEC 23 43 DSI 0.63 25 P1 02H 0.05 TEH TEC 23 47 DSI 0.21 29 P1 04H 0.00 TEH TEC 23 49 DSI 0.81 49 P1 01H 0.02 TEH TEC 23 49 DSI 0.28 81 P1 04H 0.05 TEH TEC 23 51 DSI 0.96 64 P1 02H

-0.05 TEH TEC 23 52 DS1 0.90 72 P1 01H 0.02 TEH TEC 23 52 DSI 0.46 53 P1 04H 0.12 TEH TEC 23 55 PCT 0.86 129 14 P2 AV3 0.00 TEH TEC

Beaver Valley Unit #1 Page 30 of 41 1 R1 5 S/G Examination Results 1RC-E-1B (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 23 55 WAR 0.34 112 2

AV3 0.00 07C 07H 23 55 PCT 1.71 132 22 P2 AV4 0.00 TEH TEC 23 55 WAR 0.54 112 2

AV4

-0.47 07C 07H 23 64 DSI 1.23 46 P1 01H

-0.15 TEH TEC 23 66 DSI 0.29 95 P1 07H 0.00 TEH TEC 23 69 DSI 0.90 49 P1 02H

-0.02 TEH TEC 23 69 SAI 0.24 71 6

02H

-0.05 0.26 02H 02H 23 73 DSI 1.56 35 P1 02H 0.05 TEH TEC 23 73 MAI 0.26 83 6

02H 0.04 0.33 02H 02H 23 86 PCT 0.94 131 2

P1 01C

-0.12 TEH TEC 23 86 PCT 0.68 122 17 P1 02C

-0.20 TEH TEC 23 86 VOL 0.38 103 6

02C

-0.20 02C 02C 23 88 PCT 1.49 116 29 P1 01C

-0.20 TEH TEC 23 88 VOL 0.91 102 6

01C

-0.20 01C 01C 24 11 DSI 1.03 34 P1 01H

-0.08 TEH TEC 24 13 DSI 0.28 72 P1 01H 0.08 TEH TEC 24 13 MAI 0.19 89 6

01H

-0.11 0.28 011H 01H 24 13 DSI 0.90 58 P1 03H 0.05 TEH TEC 24 13 SAI 0.11 86 6

03H 0.00 0.17 03H 03H 24 14 DSI 0.86 107 P1 01H 0.21 TEH TEC 24 14 DSI 0.77 63 P1 02H 0.00 TEH TEC 24 16 DSI 1.11 61 P1 01H 0.05 TEH TEC 24 16 DSI 0.78 77 P1 02H

-0.08 TEH TEC 24 16 SAI 0.22 88 6

02H

-0.08 0.18 02H 02H 24 17 SPR 1.65 74 P1 03H 0.00 TEH TEC 24 17 DSI 1.10 41 P1 03H 0.10 TEH TEC 24 17 SAI 0.22 121 6

03H

-0.01 0.20 03H 03H 24 32 DSI 0.14 88 P1 03H 0.17 TEH TEC 24 33 DSI 0.55 57 P1 02H 0.00 TEH TEC 24 36 DSI 0.77 117 P1 01H 0.20 TEH TEC 24 38 DSI 0.71 60 P1 01H 0.05 TEH TEC 24 38 DSI 0.39 51 P1 03H 0.00 TEH TEC 24 41 DSI 0.85 54 P1 01H 0.02 TEH TEC 24 43 DSI 1.01 85 P1 011H

-0.19 TEH TEC 24 44 SCI 0.14 96 P2 TSH 0.17 84 TSH TSH 24 45 DSI 0.33 78 P1 02H 0.00 TEH TEC 24 50 DSI 0.64 105 P1 01H

-0.05 TEH TEC 24 52 DSI 0.62 58 P1 02H 0.10 TEH TEC 24 55 DSI 0.77 123 P1 01H 0.05 TEH TEC 24 55 DSI 0.82 62 P1 02H 0.00 TEH TEC 24 56 DSI 0.51 84 P1 01H 0.07 TEH TEC 24 56 DSI 0.75 65 P1 02H 0.15 TEH TEC 24 58 DSI 0.89 37 P1 02H

-0.07 TEH TEC 24 60 DSI 0.52 80 P1 02H 0.00 TEH TEC 24 60 DSI 0.65 43 P1 03H 0.07 TEH TEC 24 60 DSI 0.97 75 P1 04H 0.32 TEH TEC 24 84 DSI 0.42 50 P1 01H 0.00 TEH TEC 24 86 PCT 1.16 122 17 P1 01C

-0.10 TEH TEC 24 87 PCT 1.16 129 13 P1 01C 0.02 TEH TEC 24 87 PCT 0.33 125 14 P1 02C

-0.17 TEH TEC 25 10 PCT 0.79 128 7

P1 01C

-0.13 TEH TEC

Beaver Valley Unit #1 Page 31 of 41 1 R1 5 S/G Examination Results 1RC-E-1B (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inchl Cr-Length Cr-Angle From To 25 10 VOL 0.52 92 6

01C

-0.13 01C 01C 25 10 PCT 0.91 114 27 P1 02C 0.13 TEH TEC 25 16 DSI 0.81 52 P1 01H 0.10 TEH TEC 25 18 SPR 1.64 93 P1 01H 0.00 TEH TEC 25 18 DSI 1.02 87 P1 01H

-0.17 TEH TEC 25 18 MAI 0.44 88 6

01H

-0.13 0.33 01H 01H 25 18 DSI 1.00 61 P1 02H

-0.10 TEH TEC 25 18 SAI 0.27 56 6

02H 0.00 0.31 02H 02H 25 20 DSI 1.01 51 P1 02H 0.00 TEH TEC 25 21 DSI 1.44 62 P1 01H 0.07 TEH TEC 25 21 DSI 1.22 49 P1 02H

-0.02 TEH TEC 25 21 SAI 0.28 74 6

02H

-0.06 0.30 02H 02H 25 22 DSI 1.41 67 P1 01H 0.05 TEH TEC 25 26 DSI 0.77 53 P1 01H 0.00 TEH TEC 25 68 DSI 0.46 72 P1 03H 0.02 TEH TEC 25 68 DSI 0.41 47 P1 03H 0.00 TEH TSC 25 71 DSI 0.23 125 P1 02H 0.02 TEH TEC 25 74 DSI 0.45 46 P1 03H 0.05 TEH TEC 25 74 DSI 0.26 78 P1 04H 0.07 TEH TEC 25 84 PCT 0.78 123 22 P1 01C

-0.24 TEH TEC 25 84 PCT 0.40 127 9

P1 02C

-0.17 TEH TEC 25 84 VOL 0.34 96 6

02C

-0.17 02C 02C 26 28 DSI 0.71 33 P1 01H 0.02 TEH TEC 26 28 SAI 0.14 107 6

01H 0.11 0.25 01H 01H 26 51 DSI 0.22 96 P1 03H 0.02 TEH TEC 26 85 PCT 1.16 119 22 P1 02C

-0.20 TEH TEC 27 13 PCT 0.53 121 21 P1 01C

-0.08 TEH TEC 27 17 DSI 0.75 58 P1 01H 0.14 TEH TEC 27 18 DSI 0.28 95 P1 02H 0.02 TEH TEC 27 18 DSI 0.76 49 P1 03H 0.05 TEH TEC 27 18 SAI 0.28 79 6

03H

-0.02 0.20 03H 03H 27 19 DSI 0.28 61 P1 02H 0.02 TEH TEC 27 19 SAI 0.30 92 6

02H 0.00 0.40 02H 02H 27 19 DSI 0.52 90 P1 03H 0.02 TEH TEC 27 21 DSI 0.61 65 P1 02H 0.00 TEH TEC 27 21 SAI 0.13 79 6

02H

-0.06 0.27 02H 02H 27 24 SCI 0.29 41 P2 TSH

-0.03 87 TSH TSH 27 47 DSI 0.36 43 P1 01H 0.02 TEH TEC 27 47 DSI 0.74 37 P1 02H

-0.02 TEH TEC 27 48 DSI 0.44 28 P1 02H 0.00 TEH TEC 27 58 DSI 0.72 36 P1 02H 0.00 TEH TEC 27 62 DSI 0.55 46 P1 01H 0.07 TEH TEC 27 75 DSI 0.66 62 P1 01H

-0.17 TEH TEC 27 75 DS0 0.54 40 P1 02H 0.00 TEH TEC 27 80 DSI 0.35 127 P1 01H

-0.02 TEH TEC 27 80 DSI 0.64 89 P1 02H

-0.02 TEH TEC 27 84 PCT 1.03 127 9

P1 01C

-0.12 TEH TEC 27 84 VOL 0.73 97 6

01C

-0.12 01C 01C 27 85 PCT 1.07 124 14 P1 01C

-0.17 TEH TEC 27 85 VOL 0.61 105 6

01C

-0.17 01C 01C 27 85 PCT 0.22 141 0

P1 02C 0.12 TEH TEC

Beaver Valley Unit #1 Page 32 of 41 1 R1 5 S/G Examination Results 1RC-E-1 B (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inchl Cr-Length Cr-Angle From To 27 85 VOL 0.21 124 6

02C

-0.17 02C 02C 28 11 DSI 0.34 118 P1 02H 0.23 TEH TEC 28 12 DSI 0.68 142 P1 011H 0.26 TEH TEC 28 26 DSI 0.36 36 P1 02H 0.02 TEH TEC 28 60 DSI 0.28 142 P1 07C 0.00 TEH TEC 28 67 DSI 0.17 102 P1 02H 0.02 TEH TEC 28 67 DSI 0.75 35 P1 04H 0.07 TEH TEC 28 82 PCT 0.85 117 24 P1 01C 0.05 TEH TEC 28 84 PCT 0.41 126 10 P1 01C

-0.22 TEH TEC 28 84 PCT 0.83 134 0

P1 02C

-0.17 TEH TEC 28 85 PCT 0.69 131 2

P1 01C

-0.20 TEH TEC 29 12 PCT 1.47 128 11 P1 01C

-0.19 TEH TEC 29 12 DSI 0.89 134 P1 011H 0.18 TEH TEC 29 14 PCT 2.21 115 25 P1 01C

-0.18 TEH TEC 29 16 DSI 0.59 41 P1 011H 0.00 TEH TEC 29 49 DSI 0.86 23 P1 02H 0.05 TEH TEC 29 84 PCT 2.89 123 22 P1 01C

-0.15 TEH TEC 29 84 VOL 1.00 95 6

01C

-0.15 01C 01C 29 84 PCT 0.58 138 0

P1 02C

-0.07 TEH TEC 30 14 PCT 1.83 119 20 P1 01C

-0.14 TEH TEC 30 14 VOL 0.38 130 6

01C

-0.14 01C 01C 30 16 PCT 0.47 129 3

P1 01C

-0.13 TEH TEC 30 17 PCT 0.88 141 0

P1 01C

-0.27 TEH TEC 30 35 DSI 0.49 46 P1 02H 0.05 TEH TEC 30 64 DSI 0.34 104 P1 07H 0.07 TEH TEC 30 74 DSI 0.34 40 P1 01H 0.00 TEH TEC 30 74 DSI 0.19 109 P1 04H 0.00 TEH TEC 30 77 DSI 0.22 66 P1 011H 0.00 TEH TEC 30 79 PCT 0.65 125 12 P1 02C

-0.10 TEH TEC 30 80 PCT 0.72 133 0

P1 01C

-0.12 TEH TEC 30 81 PCT 1.81 106 39 P1 01C

-0.02 TEH TEC 30 81 VOL 1.27 86 6

-01C

-0.02 01C 01C 30 81 PCT 0.80 142 0

P1 02C

-0.10 TEH TEC 30 81 VOL 0.61 89 6

02C

-0.10 02C 02C 30 82 PCT 1.42 129 5

P1 01C

-0.12 TEH TEC 30 82 VOL 0.65 100 6

01C 0.12 01C 01C 30 82 PCT 0.41 139 0

P1 02C

-0.02 TEH TEC 30 82 VOL 0.33 109 6

02C

-0.02 02C 02C 30 83 PCT 1.05 114 29 P1 01C

-0.05 TEH TEC 31 13 DSI 0.46 109 P1 01H 0.34 TEH TEC 31 17 PCT 1.44 133 0

P1 01C

-0.20 TEH TEC 31 22 DSI 0.71 57 P1 02H 0.10 TEH TEC 31 24 DSI 0.71 53 P1 02H 0.10 TEH TEC 31 24 DSI 0.57 20 P1 03H 0.00 TEH TEC 31 24 DSI 0.20 85 P1 04H 0.02 TEH TEC 31 34 DSI 1.72 111 P1 01H 0.17 TEH TEC 31 34 SAI 0.75 94 6

01H

-0.14 0.34 01H 01H 31 34 DSI 0.27 48 P1 02H 0.07 TEH TEC 31 36 DSI 0.77 87 P1 01H 0.10 TEH TEC 31 36 DSI 0.51 98 P1 02H

-0.02 TEH TEC 31 37 DSI 0.46 98 P1 01H 0.10 TEH TEC

Beaver Valley Unit #1 Page 33 of 41 1 R15 S/G Examination Results 1 RC-E-1 B (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inchl Cr-Length Cr-Angle From To 31 37 DSI 0.43 140 P1 02H 0.02 TEH TEC 31 37 DSI 0.42 59 P1 03H

-0.02 TEH TEC 31 38 DSI 1.17 113 P1 01H 0.10 TEH TEC 31 38 SAI 0.76 91 6

01H

-0.06 0.40 01H 01H 31 38 DSI 0.82 116 P1 02H

-0.05 TEH TEC 31 40 DSI 0.65 86 P1 02H

-0.10 TEH TEC 31 43 DSI 0.79 68 P1 02H 0.02 TEH TEC 31 43 MAI 0.44 93 6

02H 0.09 0.37 02H 02H 31 47 DSI 0.28 128 P1 01H 0.05 TEH TEC 31 47 DSI 0.49 118 P1 03H 0.10 TEH TEC 31 49 DSI 0.77 52 P1 02H

-0.05 TEH TEC 31 49 SAI 0.35 99 6

02H 0.11 0.34 02H 02H 31 62 DSI 0.56 56 P1 02H

-0.02 TEH TEC 31 62 DSI 0.45 67 P1 03H

-0.02 TEH TEC 31 64 DSI 0.55 45 P1 011H 0.05 TEH TEC 31 65 DSI 0.89 30 P1 02H 0.02 TEH TEC 31 65 SAI 0.18 97 6

02H

-0.03 0.19 02H 02H 31 65 DSI 0.28 55 P1 03H 0.02 TEH TEC 31 66 DSI 0.56 75 P1 01H 0.02 TEH TEC 31 66 DSI 0.91 95 P1 02H

-0.02 TEH TEC 31 67 DSI 0.51 31 P1 02H 0.07 TEH TEC 31 68 DSI 0.53 129 P1 01H 0.17 TEH TEC 31 68 DSI 0.61 103 P1 02H 0.00 TEH TEC 31 69 DSI 0.59 93 P1 02H

-0.07 TEH TEC 31 69 DSI 0.33 103 P1 06H 0.03 TEH TEC 31 78 PCT 1.40 112 31 P1 02C

-0.15 TEH TEC 31 78 VOL 0.32 103 6

02C

-0.15 02C 02C 32 36 DSI 0.19 33 P1 02H 0.05 TEH TEC 32 37 DSI 0.54 102 P1 01H

-0.12 TEH TEC 32 37 SAI 0.18 122 6

01H 0.12 0.20 011H 01H 32 40 DSI 0.71 86 P1 02H 0.00 TEH TEC 32 46 PCT 4.89 0

37 P2 AV2 0.70 TEH TEC 32 46 WAR 0.85 111 2

AV2 0.00 07H 07C 32 46 PCT 5.71 0

38 P2 AV3 0.20 TEH TEC 32 46 WAR 0.94 104 2

AV3 0.00 07H 07C 32 46 PCT 1.60 0

22 P2 AV4 0.62 TEH TEC 32 46 WAR 0.39 138 P2 AV4 0.00 07H 07C 32 69 DSI 0.42 92 P1 01H 0.05 TEH TEC 32 69 DSI 0.60 42 P1 02H 0.05 TEH TEC 32 71 DSI 0.30 73 P1 01H 0.10 TEH TEC 32 72 DSI 0.16 69 P1 01H 0.02 TEH TEC 32 72 DSI 0.53 53 P1 04H 0.05 TEH TEC 32 75 DSI 1.06 56 P1 01H 0.05 TEH TEC 32 76 PCT 0.46 132 0

P1 02C

-0.10 TEH TEC 32 77 PCT 0.90 0

15 P2 AV2 0.00 TEH TEC 32 78 PCT 2.04 117 24 P1 01C

-0.15 TEH TEC 32 78 VOL 0.52 110 6

01C

-0.15 01C 01C 32 78 VOL 0.32 116 6

01C

-0.15 01C 01C 32 78 PCT 1.38 129 5

P1 02C

-0.07 TEH TEC 33 25 PCT 0.93 0

16 P2 AV4 0.00 TEH TEC 33 25 WAR 0.25 130 2

AV4

-0.28 07H 07C

Beaver Valley Unit #1 Page 34 of 41 1 R1 5 S/G Examination Results 1RC-E-1B (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 33 34 DSI 0.60 122 P1 01H 0.17 TEH TEC 33 34 DSI 0.88 74 P1 02H

-0.05 TEH TEC 33 34 DSI 0.46 19 P1 03H 0.05 TEH TEC 33 35 DSI 0.43 116 P1 01H

-0.02 TEH TEC 33 35 DSI 0.85 41 P1 02H 0.10 TEH TEC 33 35 MAI 0.21 81 6

02H

-0.13 0.29 02H 02H 33 36 DSI 0.35 154 P1 01H 0.10 TEH TEC 33 38 DSI 0.32 35 P1 02H 0.10 TEH TEC 33 39 DSI 1.24 86 P1 01H 0.12 TEH TEC 33 39 DSI 1.06 103 P1 02H

-0.05 TEH TEC 33 39 SPR 1.55 89 P1 02H 0.00 TEH TEC 33 39 SAI 0.56 109 6

02H

-0.10 0.42 02H 02H 33 39 DSI 0.66 60 P1 03H 0.02 TEH TEC 33 40 DSI 0.87 81 P1 011H 0.00 07H TEH 33 40 SAI 0.37 85 6

01H 0.04 0.34 01H 01H 33 46 DSI 0.32 66 P1 01H

-0.03 07H TEH 33 46 DSI 0.26 54 P1 07H 0.05 07H TEC 33 46 DSI 0.25 44 P1 07H

-0.03 07H TEH 33 47 DSI 0.21 51 P1 01H 0.00 07H TEH 33 48 DSI 0.43 104 P1 01H

-0.03 07H TEH 33 51 DSI 0.68 121 P1 O1H

-0.03 07H TEH 33 51 DSI 1.29 73 P1 02H

-0.12 07H TEH 33 51 DSI 1.26 82 P1 03H

-0.35 07H TEH 33 51 DSI 0.67 92 P1 04H

-0.12 07H TEH 33 53 DSI 0.60 68 P1 03H

-0.09 07H TEH 33 53 DSI 0.31 33 P1 04H

-0.03 07H TEH 33 54 DSI 1.47 79 P1 02H 0.06 07H TEH 33 54 DS0 0.21 116 P1 06H

-0.09 07H TEH 33 55 DSI 0.81 31 P1 02H 0.07 TEH TEC 33 55 SAI 0.42 91 6

02H

-0.20 0.43 02H 02H 33 55 DSI 0.60 47 P1 03H 0.07 TEH TEC 33 55 DSI 1.05 66 P1 04H

-0.17 TEH TEC 33 57 DSI 0.49 51 P1 03H 0.02 TEH TEC 33 58 DSI 0.55 92 P1 01H 0.10 TEH TEC 33 59 DSI 1.05 69 P1 02H 0.02 TEH TEC 33 59 DSI 0.49 64 P1 03H 0.02 TEH TEC 33 59 DSI 0.86 66 P1 05H 0.05 TEH TEC 33 61 DSI 0.69 99 P1 O1H 0.02 TEH TEC 33 70 PCT 1.59 0

22 P2 AV3 0.00 TEH TEC 33 70 WAR 0.23 119 2

AV3 0.00 07H 07C 33 72 DSI 0.67 63 P1 01H 0.05 TEH TEC 33 75 DSI 0.38 137 P1 01H

-0.07 TEH TEC 33 75 PCT 0.43 126 10 P1 02C 0.00 TEH TEC 33 75 DSI 0.26 104 P1 03H 0.12 TEH TEC 33 75 DSI 0.40 70 P1 05H 0.00 TEH TEC 33 76 DSI 0.73 73 P1 01H 0.07 TEH TEC 34 18 PCT 1.11 132 0

P1 01C

-0.23 TEH TEC 34 18 PCT 0.85 133 2

P1 02C 0.12 TEH TEC 34 18 VOL 0.53 130 6

02C 0.08 02C 02C 34 24 DSI 0.96 128 P1 01H

-0.05 TEH TEC 34 26 DSI 0.73 101 P1 O1H 0.12 TEH TEC

Beaver Valley Unit #1 Page 35 of 41 1 R1 5 S/G Examination Results 1RC-E-1B (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inchl Cr-Length Cr-Angle From To 34 28 DSI 0.34 55 P1 03H 0.20 TEH TEC 34 29 DSI 0.70 48 P1 01H 0.07 TEH TEC 34 29 MAI 0.26 108 6

01H 0.01 0.37 01H 01H 34 29 DSI 0.61 101 P1 02H 0.02 TEH TEC 34 29 DSI 1.03 135 P1 03H 0.25 TEH TEC 34 29 DSI 0.36 92 P1 05H 0.12 TEH TEC 34 30 DSI 1.09 16 P1 02H 0.17 TEH TEC 34 30 SAI 0.14 103 6

02H 0.14 0.37 02H 02H 34 32 DSI 0.74 133 P1 02H

-0.28 TEC TEH 34 32 SPR 1.98 155 P1 02H 0.03 TEC TEH 34 32 SAI 0.47 108 6

02H

-0.09 0.37 02H 02H 34 32 MAI 0.22 117 6

05H 0.00 0.34 05H 05H 34 32 DSI 1.80 20 P1 05H

-0.08 TEC TEH 34 33 DSI 1.35 109 P1 01H 0.15 TEH TEC 34 36 DSI 0.73 141 P1 01K 0.15 TEH TEC 34 36 DSI 0.50 104 P1 03H

-0.05 TEH TEC 34 37 DSI 1.44 100 P1 02H 0.12 TEH TEC 34 37 MAI 0.67 98 6

02H

-0.11 0.37 02H 02H 34 37 DSI 0.74 115 P1 03H 0.15 TEH TEC 34 37 MAI 0.66 91 6

03H 0.15 0.50 03H 03H 34 37 DSI 0.73 88 P1 04H 0.02 TEH TEC 34 37 MAI 0.36 111 6

04H 0.03 0.50 04H 04H 34 41 DSI 0.78 121 P1 02H

-0.09 07H TEH 34 43 DSI 0.67 98 P1 05H

-0.06 07H TEH 34 44 DSI 0.70 127 P1 01H

-0.21 07H TEH 34 44 MAI 0.20 101 6

01H 0.06 0.31 01H 01H 34 44 MAI 0.19 123 6

01H 0.11 0.29 01H 01H 34 44 DSI 0.53 35 P1 02H

-0.06 07H TEH 34 50 DSI 0.60 96 P1 04H

-0.09 07H TEH 34 50 SAI 0.27 100 6

04H 0.07 0.24 04H 04H 34 51 DSI 0.86 107 P1 01H 0.15 07H TEH 34 56 DSI 0.11 106 P1 01H 0.10 TEH TEC 34 56 SAI 0.60 107 6

01H

-0.21 0.60 O1H 01H 34 56 DSI 0.65 104 P1 02H 0.15 TEH TEC 34 56 MAI 0.26 95 6

02H 0.03 0.34 02H 02H 34 62 DSI 0.96 101 P1 01H 0.07 TEH TEC 34 65 DSI 0.53 111 P1 01H

-0.02 TEH TEC 34 78 PCT 1.86 125 12 P1 01C

-0.02 TEH TEC 34 79 PCT 1.33 145 0

P1 01C 0.02 TEH TEC 34 79 VOL 0.86 100 6

01C 0.02 01C 01C 35 17 PCT 1.12 123 18 P1 01C

-0.26 TEH TEC 35 18 PCT 0.73 136 0

P1 02C

-0.17 TEH TEC 35 26 DSI 1.18 104 P1 01H 0.12 TEH TEC 35 27 DSI 1.03 99 P1 01H

-0.02 TEH TEC 35 27 MAI 0.77 92 6

01H 0.09 0.42 01K 01H 35 28 DSI 0.50 99 P1 01H

-0.05 TEH TEC 35 28 DSI 0.64 43 P1 03H 0.05 TEH TEC 35 28 SAI 0.29 73 6

03H

-0.06 0.26 03H 03H 35 34 DSI 0.60 129 P1 01K 0.07 TEH TEC 35 34 DSI 0.67 77 P1 02H

-0.02 TEH TEC 35 35 DSI 0.77 28 P1 04H 0.00 TEH TEC

Beaver Valley Unit #1 Page 36 of 41 1 R1 5 S/G Examination Results 1 RC-E-1 B (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 35 35 SAI 0.13 123 6

04H 0.00 0.21 04H 04H 35 36 DSI 0.61 65 P1 02H 0.02 TEH TEC 35 36 SAI 0.43 94 6

02H 0.11 0.32 02H 02H 35 37 DSI 0.91 60 P1 02H 0.02 TEH TEC 35 40 DSI 0.44 44 P1 02H 0.00 07H TEH 35 41 DSI 0.77 75 P1 01H

-0.03 07H TEH 35 44 DSI 0.49 129 P1 02H

-0.09 07H TEH 35 51 PVN 3.28 28 2

AV1 24.33 07H 07C 35 51 PVN 2.79 33 2

AV1 24.33 07C 07H 35 58 DSI 0.37 36 P1 03H 0.05 TEH TEC 35 67 DSI 0.61 55 P1 02H 0.05 TEH TEC 35 67 MAI 0.23 107 6

02H 0.04 0.24 02H 02H 35 67 WAR 0.24 105 2

AV2 0.00 07H 07C 35 71 NOI 1.17 119 3

06C 13.26 TEH TEC 35 73 PCT 0.51 150 0

P1 01C

-0.17 TEH TEC 35 73 DSI 0.85 60 P1 04H 0.07 TEH TEC 35 73 WAR 0.29 109 2

AV2 0.00 07H 07C 35 75 PCT 2.84 109 35 P1

.02C

-0.15 TEH TEC 35 75 VOL 1.16 98 6

02C

-0.15 02C 02C 35 76 PCT 0.23 127 9

P1 01C

-0.07 TEH TEC 35 78 PCT 2.10 141 0

P1 01C

-0.05 TEH TEC 35 78 PVN 1.01 38 6

TSH 9.08 TSH TSH 36 20 PCT 0.76 148 0

P1 02C

-0.17 TEH TEC 36 20 VOL 0.43 156 6

02C

-0.21 02C 02C 36 23 DSI 0.43 119 P1 011H 0.10 TEH TEC 36 23 DSI 0.44 111 P1 03H 0.07 TEH TEC 36 23 DSI 0.24 120 P1 06H

-0.05 TEH TEC 36 26 PCT 2.65 0

28 P2 AV2

-0.02 TEH TEC 36 26 WAR 0.19 131 2

AV2 0.01 07H 07C 36 26 WAR 0.24 114 2

AV2 0.09 07H 07C 36 26 PCT 5.20 0

37 P2 AV3 0.00 TEH TEC 36 26 WAR 0.95 110 2

AV3 0.00 07H 07C 36 26 PCT 2.04 0

25 P2 AV4

-0.17 TEH TEC 36 26 WAR 0.49 136 P2 AV4 0.00 07H 07C 36 27 DSI 0.71 109 P1 02H

-0.17 TEH TEC 36 27 SAI 0.21 52 6

02H

-0.03 0.29 02H 02H 36 29 DSI 0.99 118 P1 01H 0.22 TEH TEC 36 30 DSI 0.60 145 P1 01H 0.12 TEH TEC 36 39 DSI 0.76 149 P1 01H 0.17 TEH TEC 36 49 DSI 0.53 123 P1 01H

-0.03 07H TEH 36 49 DSI 0.36 73 P1 04H 0.00 07H TEH 36 56 DSI 0.63 35 P1 02H 0.00 TEH TEC 36 56 SAI 0.32 106 6

02H

-0.11 0.31 04H 02H 36 56 DSI 0.59 119 P1 03H

-0.20 TEH TEC 36 56 MAI 0.27 95 6

03H

-0.01 0.37 03H 03H 36 56 DSI 1.23 102 P1 04H 0.25 TEH TEC 36 56 SPR 1.79 104 P1 04H 0.00 TEH TEC 36 56 SAI 0.27 103 6

04H 0.00 0.32 04H 04H 36 60 PVN 0.64 39 2

07H 24.21 07H 07C 36 60 PVN 3.29 45 6

TSH -12.50 TSH TSH 36 61 PCT 1.65 0

22 P2 AV3

-0.35 TEH TEC

Beaver Valley Unit #1 Page 37 of 41 1 R1 5 S/G Examination Results 1 RC-E-1 B (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 36 61 WAR 0.37 132 2

AV3 0.00 07H 07C 36 72 PCT 0.43 139 0

P1 01C -0.25 TEH TEC 36 73 PCT 1.88 114 37 P1 01C -0.17 TEH TEC 36 75 PCT 1.51 140 0

P1 01C 0.02 TEH TEC 36 75 PCT 0.27 115 27 P1 02C

-0.20 TEH TEC 36 76 PCT 0.75 152 0

P1 01C

-0.05 TEH TEC 36 76 VOL 0.25 136 6

01C -0.05 01C 01C 37 19 PVN 4.24 31 2

07H

-1.76 07H 07C 37 19 PVN 2.36 28 2

07H

-1.76 07C 07H 37 21 PCT 1.50 138 0

P1 02C

-0.22 TEH TEC 37 22 PCT 0.47 142 5

P1 01C

-0.23 TEH TEC 37 22 PCT 0.84 141 7

P1 02C

-0.20 TEH TEC 37 27 SPR 1.82 145 P1 01H 0.00 TEH TEC 37 27 DSI 1.02 12 P1 01H 0.12 TEH TEC 37 27 SAI 0.43 90 6

01H 0.12 0.29 01H 01H 37 31 DSI 1.37 101 P1 01H

-0.02 TEH TEC 37 31 DSI 0.55 54 P1 03H 0.17 TEH TEC 37 31 SAI 0.56 98 6

03H 0.10 0.48 03H 03H 37 37 DSI 0.48 59 P1 04H 0.00 TEH TEC 37 43 PCT 1.96 97 27 P2 AV2 0.00 07H TEC 37 43 WAR 0.40 0

2 AV2 0.15 07H 07C 37 43 WAR 0.60 0

2 AV2

-0.15 07H 07C 37 43 PCT 2.18 60 28 P2 AV3 0.00 07H TEC 37 55 DSI 0.22 94 P1 01H 0.05 TEH TEC 37 57 DSI 0.97 79 P1 02H 0.00 TEH TEC 37 65 DSI 0.58 90 P1 03H 0.05 TEH TEC 37 74 PCT 1.35 130 6

P1 02C 0.10 TEH TEC 37 74 VOL 0.67 115 6

02C 0.10 02C 02C 37 75 PCT 0.77 146 0

P1 01C

-0.02 TEH TEC 37 76 PCT 0.83 149 0

P1 01C

-0.17 TEH TEC 37 76 PCT 0.74 133 0

P1 02C

-0.12 TEH TEC 37 76 VOL 0.44 99 6

02C

-0.12 02C 02C 38 21 PCT 0.53 153 0

P1 02C

-0.10 TEH TEC 38 26 PCT 1.16 0

17 P2 AV2

-0.05 TEH TEC 38 27 PCT 0.65 119 22 P1 02C

-0.27 TEH TEC 38 27 VOL 0.75 98 6

02C

-0.17 02C 02C 38 31 DSI 0.56 162 P1 06H 0.10 TEH TEC 38 32 DSI 0.47 56 P1 02H 0.07 TEH TEC 38 44 DSI 0.83 77 P1 01H 0.03 07H TEH 38 45 SAI 0.83 15 6

TSH

-0.25 0.36 TSH TSH 38 49 PVN 1.17 217 6

TSH

-1.30 TSH TSH 38 62 DSI 0.38 123 P1 01H 0.05 TEH TEC 38 68 PCT 0.17 128 12 P1 02C 0.00 TEH TEC 38 69 PCT 0.34 119 31 P1 02C

-0.10 TEH TEC 38 72 DSI 0.53 31 P1 01H

-0.05 TEH TEC 38 72 PCT 1.60 127 11 P1 02C 0.12 TEH TEC 39 22 PCT 2.16 0

26 P2 AV4 0.00 TEH TEC 39 22 WAR 0.49 132 P2 AV4 0.00 07H 07C 39 23 PCT 1.15 127 23 P1 02C

-0.19 TEH TEC 39 24 PCT 0.94 138 0

P1 01C

-0.10 TEH TEC 39 24 VOL 0.93 96 6

01C

-0.02 01C 01C

Beaver Valley Unit #1 Page 38 of 41 1 R1 5 S/G Examination Results 1 RC-E-1 B (TUBES WITH INDICATIONS)

Row CoI Ind Volts Phase %TW Chan Loc Inchl Cr-Length Cr-Angle From To 39 24 PCT 1.29 148 0

P1 02C

-0.17 TEH TEC 39 26 PCT 0.54 137 5

P1 01C

-0.18 TEH TEC 39 26 DSI 0.63 141 P1 01H 0.05 TEH TEC 39 26 PCT 0.77 151 0

P1 02C

-0.22 TEH TEC 39 26 DSI 0.48 132 P1 02H 0.17 TEH TEC 39 38 DSI 0.65 82 P1 01H 0.00 TEH TEC 39 39 PCT 2.16 0

26 P2 AV3 0.02 TEH TEC 39 39 WAR 0.58 123 2

AV3 0.00 07H 07C 39 39 PCT 1.84 0

24 P2 AV4 0.23 TEH TEC 39 39 WAR 0.51 111 2

AV4 0.33 07H 07C 39 43 DSI 0.33 127 P1 01H

-0.06 07H TEH 39 44 DSI 0.91 98 P1 02H 0.06 07H TEH 39 48 DSI 1.66 92 P1 01H 0.00 07H TEH 39 48 PCT 1.63 57 25 P2 AV3 0.00 07H TEC 39 48 NOI 0.81 113 3

AV3 15.38 07H TEC 39 48 WAR 0.53 117 2

AV3 0.00 07H 07C 39 48 PCT 2.15 36 28 P2 AV4 0.00 07H TEC 39 48 WAR 0.48 124 2

AV4 0.00 07H 07C 39 51 PCT 1.19 0

16 P2 AV3 0.00 07H TEC 39 52 DSI 0.96 104 P1 01H 0.00 07H TEH 39 56 PCT 2.83 0

30 P2 AV3 0.00 TEH TEC 39 56 WAR 0.60 114 2

AV3 0.00 07H 07C 39 56 PCT 1.57 0

22 P2 AV4 0.00 TEH TEC 39 56 WAR 0.50 109 2

AV4 0.02 07H 07C 39 57 DSI 0.57 78 P1 05H

-0.10 TEH TEC 39 57 PCT 4.12 39 34 P2 AV3 0.41 TEH TEC 39 57 WAR 0.28 127 2

AV3

-0.25 07H 07C 39 57 WAR 0.78 105 2

AV3 0.33 07H 07C 39 57 PCT 1.78 64 23 P2 AV4 0.18 TEH TEC 39 57 WAR 0.36 119 2

AV4 0.33 07H 07C 39 57 WAR 0.37 127 2

AV4

-0.36 07H 07C 39 58 PVN 0.39 44 P2 07H 19.02 07H 07C 39 58 PCT 2.11 100 28 P2 AV3 0.00 TEH TEC 39 58 WAR 0.48 121 2

AV3 0.00 07H 07C 39 58 WAR 0.50 127 2

AV3 0.01 07C 07H 39 59 PVN 1.85 37 2

07H

-0.33 07H 07C 39 59 PVN 2.04 30 2

07H

-0.33 07C 07H 39 60 PCT 1.33 0

19 P2 AV3 0.02 TEH TEC 39 60 WAR 0.28 0

2 AV3 0.02 07H 07C 39 60 PCT 2.15 85 25 P2 AV4

-0.05 TEH TEC 39 60 WAR 0.36 0

2 AV4

-0.04 07H 07C 39 61 PCT 4.53 41 36 P2 AV3 0.40 TEH TEC 39 61 WAR 0.81 117 2

AV3 0.00 07H 07C 39 71 PCT 0.32 150 0

P1 01C 0.02 TEH TEC 39 71 PCT 0.58 135 11 P1 02C

-0.17 TEH TEC 39 71 VOL 0.38 136 6

02C

-0.17 02C 02C 39 71 PCT 1.15 125 17 P2 AVI 0.00 TEH TEC 39 72 PCT 1.57 123 26 P1 02C 0.15 TEH TEC 39 72 DSI 0.27 65 P1 03H 0.02 TEH TEC 39 73 PCT 0.99 127 12 P1 02C 0.12 TEH TEC 40 24 PCT 0.42 134 6

P1 01C

-0.20 TEH TEC

Beaver Valley Unit #1 1 R15 S/G Examination Results 1 RC-E-1 B (TUBES WITH INDICATIONS)

Page 39 of 41 Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 40 27 PCT 0.43 40 27 PCT 1.08 40 28 PCT 0.44 40 53 PCT 1.11 40 53 WAR 0.20 40 53 PCT 1.12 40 53 WAR 0.12 40 66 PCT 0.74 40 70 PCT 1.02 40 70 PCT 1.19 40 71 DSI 0.39 40 71 DSI 1.07 40 71 SAI 0.27 41 26 PCT 0.91 41 26 PCT 1.87 41 27 PCT 2.14 41 35 PVN 2.79 41 35 PVN 1.47 41 41 PCT 0.32 41 41 WAR 0.28 41 43 PCT 1.50 41 43 WAR 0.41 41 43 PCT 3.80 41 43 WAR 0.73 41 43 PCT 4.52 41 43 WAR 0.95 41 43 PCT 1.95 41 43 WAR 0.36 41 46 DSI 1.38 41 51 PCT 1.70 41 51 WAR 0.28 41 51 PCT 1.66 41 51 WAR 0.36 41 53 DSI 0.74 41 54 PVN 3.32 41 54 PVN 4.30 41 61 PCT 0.86 41 61 WAR 0.23 41 64 PCT 0.93 41 64 WAR 0.20 41 66 PCT 1.13 41 69 PCT 0.56 41 69 VOL 0.39 42 28 PCT 1.55 42 29 PCT 0.93 42 30 PCT 0.60 42 33 PCT 1.98 42 35 PCT 0.38 42 36 PCT 0.84 42 51 DSI 1.20 42 52 PCT 1.33 131 11 P1 01C

-0.25 140 0

P1 02C

-0.15 146 0

P1 02C

-0.07 144 20 P2 AV3 0.00 113 2

AV3 0.00 44 20 P2 AV4 0.00 80 2

AV4 0.00 136 0

P1 02C 0.12 120 21 P1 01C

-0.22 123 17 P1 02C

-0.20 90 P1 01H

-0.02 64 P1 02H 0.07 104 6

02H 0.03 131 10 P1 01C

-0.25 118 28 P1 02C

-0.17 118 29 P1 02C

-0.17 46 P2 07H 7.08 37 P2 07H 7.08 0

5 P2 AV4 0.00 136 2

AV4 0.00 0

19 P2 AV1 0.00 126 2

AV1 0.00 0

33 P2 AV2 0.00 113 2

AV2 0.00 0

35 P2 AV3 0.00 106 2

AV3 0.00 49 27 P2 AV4 0.00 142 2

AV4 0.00 99 P1 01H 0.00 80 25 P2 AV3 0.00 146 P2 AV3 0.00 57 25 P2 AV4 0.05 135 P2 AV4 0.00 62 P1 02H 0.00 45 P2 07H 1.21 32 P2 07H 1.21 38 15 P2 AV1

-0.05 167 2

AV1 0.00 78 15 P2 AV3 0.00 123 2

AV3 0.00 130 9

P1 01C

-0.12 133 3

P1 02C

-0.07 92 6

02C

-0.07 127 15 P1 02C 0.02 132 7

P1 02C 0.02 130 10 P1 02C

-0.12 118 29 P1 02C

-0.17 137 2

P1 02C

-0.15 125 20 P1 01C

-0.02 110 P1 01H 0.03 46 19 P2 AV1 0.05 0.24 TEH TEC TEH TEC TEH TEC 07H TEC 07H 07C 07H TEC 07H 07C TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 02H 02H TEH TEC TEH TEC TEH TEC 07H 07C 07C 07H 07H TEC 07H 07C 07H TEC 07H 07C 07H TEC 07H 07C 07H TEC 07H 07C 07H TEC 07H 07C 07H TEH 07H TEC 07H 07C 07H TEC 07H 07C 07H TEH 07H 07C 07C 07H TEH TEC 07H 07C TEH TEC 07H 07C TEH TEC TEH TEC 02C 02C TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 07H TEH 07H TEC

Beaver Valley Unit #1 Page 40 of 41 1 R1 5 S/G Examination Results 1RC-E-1B (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 42 52 PCT 0.74 103 13 P2 AV2 0.00 07H TEC 42 57 PCT 0.55 121 0

P1 01C

-0.20 TEH TEC 42 59 PCT 0.48 133 2

P1 02C

-0.05 TEH TEC 42 60 PCT 0.91 138 0

P1 02C

-0.24 TEH TEC 42 62 PCT 0.54 134 3

P1 01C

-0.10 TEH TEC 42 62 DSI 0.50 60 P1 04H 0.02 TEH TEC 42 62 DSI 0.42 132 P1 05H 0.15 TEH TEC 43 31 PCT 1.57 0

21 P2 AV4 0.00 TEH TEC 43 31 WAR 0.29 121 2

AV4 0.00 07H 07C 43 34 PCT 1.32 128 16 P1 01C

-0.17 TEH TEC 43 34 PCT 1.01 130 13 P1 02C 0.02 TEH TEC 43 36 PCT 0.48 151 0

P1 01C 0.02 TEH TEC 43 36 PCT 0.72 137 0

P1 02C

-0.20 TEH TEC 43 38 DSI 0.49 97 P1 01H 0.32 TEH TEC 43 41 DSI 0.16 85 P1 05H 0.00 07H TEH 43 45 DSI 0.71 106 P1 01H

-0.03 07H TEH 43 48 DSI 1.00 128 P1 01H

-0.15 07H TEH 43 49 DSI 0.31 99 P1 011H

-0.03 07H TEH 43 50 PCT 0.47 132 4

P1 01C 0.10 07H TEC 43 57 PCT 1.43 0

22 P2 AV1 0.00 TEH TEC 43 57 WAR 0.17 129 2

AVi 0.00 07H 07C 43 59 PCT 1.69 129 8

P1 01C

-0.15 TEH TEC 43 59 PCT 1.45 0

22 P2 AV1 0.00 TEH TEC 43 59 WAR 0.20 127 2

AV1 0.00 07H 07C 43 61 PCT 0.46 134 3

P1 02C

-0.22 TEH TEC 43 61 PCT 1.36 0

19 P2 AV1 0.00 TEH TEC 43 61 WAR 0.24 111 2

AV1 0.00 07H 07C 43 63 PCT 0.69 135 6

P1 02C

-0.07 TEH TEC 43 64 DSI 0.63 139 P1 011H

-0.10 TEH TEC 43 64 PCT 0.48 120 21 P1 02C

-0.22 TEH TEC 43 65 PCT 1.26 128 16 P1 02C 0.07 TEH TEC 44 36 PCT 0.64 152 0

P1 01C

-0.07 TEH TEC 44 36 PCT 0.99 115 31 P1 02C 0.07 TEH TEC 44 37 PCT 0.78 130 10 P1 01C

-0.10 TEH TEC 44 37 PCT 0.53 131 8

P1 02C 0.00 TEH TEC 44 37 VOL 0.31 111 6

02C

-0.01 02C 02C 44 38 PCT 1.13 117 28 P1 01C

-0.10 TEH TEC 44 38 PCT 1.78 125 17 P1 02C

-0.20 TEH TEC 44 39 PCT 0.51 143 0

P1 02C 0.07 TEH TEC 44 41 PCT 0.32 130 7

P1 02C 0.10 07H TEC 44 41 PCT 0.89 0

13 P2 AV4 0.00 07H TEC 44 41 WAR 0.20 176 2

AV4 0.00 07H 07C 44 43 PCT 0.85 134 4

P1 02C

-0.19 07H TEC 44 43 PCT 1.06 0

15 P2 AVi 0.00 07H TEC 44 43 WAR 0.22 30 2

AVI 0.00 07H 07C 44 44 PCT 0.32 127 16 P1 01C

-0.02 07H TEC 44 50 PCT 0.35 122 20 P1 01C 0.00 07H TEC 44 50 PCT 0.68 128 10 P1 02C

-0.22 07H TEC 44 50 PCT 1.19 0

16 P2 AV4 0.00 07H TEC 44 50 WAR 0.25 139 2

AV4 0.03 07H 07C 44 51 PCT 0.53 129 9

P1 01C

-0.25 07H TEC

Beaver Valley Unit #1 Page 41 of 41 1 R1 5 S/G Examination Results 1RC-E-1B (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 44 57 PCT 0.55 113 16 P1 01C -0.07 TEH TEC 44 57 PCT 0.79 137 0

P1 02C 0.00 TEH TEC 44 58 PCT 1.00 142 0

P1 01C 0.00 TEH TEC 44 59 PCT 0.65 134 2

P1 01C

-0.15 TEH TEC 44 59 PCT 0.61 137 0

P1 02C

-0.10 TEH TEC 44 60 PVN 0.91 35 P2 AV1 6.48 07H 07C 44 60 PVN 0.69 28 P2 AV1 6.48 07C 07H 44 62 DSI 0.51 138 P1 01H 0.07 TEH TEC 44 62 PCT 1.61 119 25 P1 02C

-0.20 TEH TEC 45 36 PCT 0.67 132 1

P1 01C 0.07 TEH TEC 45 36 PCT 1.51 109 43 P1 02C 0.02 TEH TEC 45 36 VOL 1.27 108 6

02C 0.00 02C 02C 45 39 DSI 0.80 124 P1 01H 0.17 TEH TEC 45 39 PCT 1.79 128 15 P1 02C

-0.17 TEH TEC 45 40 DSI 0.49 118 P1 03H 0.25 TEH TEC 45 40 DSI 0.41 123 P1 03H 0.20 07H TEH 45 41 PSI 19.87 131 8

07H

-0.08 07H TEC 45 41 CSI 0.22 80 11 07H 0.06 42 07H 07H 45 42 PCT 0.98 129 13 P1 01C

-0.12 07H TEC 45 42 PCT 1.88 126 17 P1 02C

-0.17 07H TEC 45 43 PCT 0.82 130 7

P1 01C 0.00 07H TEC 45 43 PCT 0.83 125 15 P1 02C

-0.02 07H TEC 45 44 PCT 1.11 126 17 P1 01C

-0.05 07H TEC 45 44 PCT 0.81 132 8

P1 02C 0.00 07H TEC 45 45 PCT 0.36 132 4

P1 02C

-0.24 07H TEC 45 46 PCT 0.48 142 0

P1 01C

-0.12 07H TEC 45 46 PCT 1.23 140 0

P1 02C

-0.19 07H TEC 45 47 PCT 0.69 124 22 P1 01C

-0.20 07H TEC 45 47 PCT 0.75 151 0

P1 02C

-0.07 07H TEC 45 49 PCT 1.38 124 22 P1 01C

-0.12 07H TEC 45 56 PCT 0.84 135 5

P1 02C

-0.10 TEH TEC 45 57 PCT 0.96 139 2

P1 01C

-0.10 TEH TEC 45 58 PCT 0.80 139 2

P1 01C

-0.05 TEH TEC 45 58 PCT 0.38 136 6

P1 02C

-0.22 TEH TEC 45 58 VOL 0.19 95 6

02C

-0.22 02C 02C 46 41 PSI 21.21 124 8

07H

-0.07 07H TEC 46 41 CSI 0.22 71 11 07H

-0.03 42 07H 07H 46 44 PCT 0.87 125 15 P1 01C 0.15 07H TEC 46 45 PCT 1.48 114 31 P1 02C

-0.10 07H TEC 46 46 PCT 1.15 116 29 P1 01C

-0.12 07H TEC 46 46 PCT 1.19 122 23 P1 02C 0.02 07H TEC 46 49 PCT 0.69 148 0

P1 01C

-0.10 07H TEC

ATTACHMENT 2A BEAVER VALLEY UNIT #1 1R15 S/G EXAMINATION RESULTS IRC-E-lB TUBES REMOVED FROM SERVICE

Beaver Valley Unit #1 Page 1 of 2 1 R1 5 S/G Examination Results 1 RC-E-1 B (TUBES REMOVED FROM SERVICE)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 2

19 DSI 2.00 97 P1 01H

-0.15 07H TEH 2

19 MAI 1.00 85 6

01H

-0.12 0.42 01H 01H 3

65 MAI 0.33 112 6

03H 0.05 0.50 03H 03H 4

29 DSI 2.02 105 P1 01H

-0.20 07H TEH 4

29 MAI 0.74 93 6

01H

-0.19 0.44 01H 01H 5

50 PTP 1.01 67 6

STH 1.20 STH STH 5

78 SAI 1.56 23 6

TSH

-1.62 0.29 TSH TSH 5

79 DNT 3.10 181 P1 04H

-0.15 TEH TEC 5

79 SAI 0.36 88 6

04H 0.16 0.28 04H 04H 5

86 SAI 1.22 19 6

TSH

-9.79 0.26 TSH TSH 7

13 SAI 0.14 102 6

02H 0.00 0.20 02H 02H 7

28 SAI 0.18 109 6

TSH 0.18 0.23 TSH TSH 7

35 SAI 0.22 89 6

TSH 0.60 0.40 TSH TSH 7

38 PTP 0.80 82 6

STH 1.21 STH STH 7

40 SAI 0.19 81 6

TSH 0.17 0.24 TSH TSH 7

54 SAI 0.24 82 6

02H

-0.07 0.40 02H 02H 7

78 SAI 0.63 91 6

01H 0.19 0.33 01H 01H 7

84 SAI 0.20 85 6

04H

-0.17 0.21 04H 04H 7

93 SVI 0.33 129 P2 01H 0.00 0.40 30 01H 01H 8

21 SAI 0.30 81 6

TSH 0.02 0.25 TSH TSH 9

9 SAI 0.61 92 6

01H 0.01 0.47 01H 01H 9

25 OBS BULGED TUBESHEET SLEEVE 9

34 PTP 0.71 88 4

STH 1.39 STH STH 9

40 PTP 0.25 56 6

STH 1.13 STH STH 10 27 SAI 0.13 87 6

TSH 0.79 0.53 TSH TSH 10 34 SAI 0.16 80 6

TSH 2.76 0.25 TSH TSH 10 61 PTP 2.21 78 6

STH 1.30 STH STH 10 66 DSI 2.05 113 P1 02H 0.10 TEH TEC 10 66 MAI 0.88 82 6

02H 0.02 0.40 02H 02H 11 20 NOI 0.61 111 3

TSC 5.31 TEH TEC 11 37 SAI 0.15 99 6

TSH 2.71 0.61 TSH TSH 11 40 PTP 1.07 69 6

STH 1.21 STH STH 11 41 PTP 0.63 95 6

STH 1.13 STH STH 11 42 SAI 0.16 87 6

TSH 0.65 0.71 TSH TSH 11 47 PTP 0.83 69

.4 STH 1.04 STH STH 12 25 SAI 0.13 84 6

TSH 0.78 0.35 TSH TSH 12 36 SAI 0.21 88 6

TSH 3.40 0.50 TSH TSH 12 42 SAI 0.17 96 6

TSH 3.23 0.86 TSH TSH 12 51 SAI 0.26 115 6

TSH 0.35 0.39 TSH TSH 12 52 SAI 0.07 103 6

TSH 0.57 0.32 TSH TSH 12 55 SAI 0.23 93 6

TSH 0.14 0.19 TSH TSH 13 36 PTP 0.55 57 6

STH 1.16 STH STH 13 53 MAI 0.19 100 6

TSH 0.50 0.90 TSH TSH 13 55 NOI 0.55 138 3

TSC 1.73 STH TEC 14 6

DSI 2.00 95 P1 01H 0.13 TEH TEC 14 6

SAI 1.05 91 6

01H 0.01 0.59 01H 01H 14 34 SAI 0.16 91 6

TSH 3.31 0.28 TSH TSH 14 37 SAI 0.25 83 6

TSH 3.57 0.38 TSH TSH 14 37 SAI 0.11 82 6

TSH 3.39 0.38 TSH TSH 14 37 SAI 0.20 74 6

TSH 2.88 0.36 TSH TSH 15 13 SAI 0.22 84 6

02H

-0.13 0.23 02H 02H

Beaver Valley Unit #1 1 R1 5 S/G Examination Results 1RC-E-1B (TUBES REMOVED FROM SERVICE)

Page 2 of 2 Row Col 15 15 15 31 15 39 15 39 15 45 15 51 15 53 15 65 16 10 16 22 16 25 16 35 16 45 16 47 16 51 16 75 17 16 17 32 17 40 17 43 17 44 18 5

18 5

18 15 18 40 19 41 19 82 19 82 20 14 20 34 20 58 20 58 22 12 23 17 24 17 24 44 25 18 27 24 33 39 34 32 36 56 37 27 38 45 45 36 Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To MAI 0.30 86 6

02H

-0.02 0.37 02H 02H PTP 0.77 84 6

STH 1.03 STH STH SAI 0.36 88 6

TSH 3.33 0.69 TSH TSH SAI 0.32 72 6

TSH 2.57 0.28 TSH TSH SAI 0.24 94 6

TSH 0.61 0.46 TSH TSH PTP 0.88 57 6

STH 1.03 STH STH SAI 0.34 83 6

TSH 0.40 0.47 TSH TSH SAI 0.37 95 6

02H

-0.11 0.31 02H 02H MAI 0.54 87 6

02H

-0.12 0.37 02H 02H SAI 0.47 11 6

TSH

-0.59 0.27 TSH TSH MAI 0.31 106 6

01H 0.02 0.33 01H 01H PTP 0.58 53 6

STH 1.29 STH STH PTP 0.62 69 4

STH 0.71 STH STH SAI 0.22 71 6

TSH 0.33 0.31 TSH TSH MAI 0.31 81 6

TSH 0.23 0.31 TSH TSH MAI 0.51 88 6

01H 0.06 0.30 01H 01H SAI 0.30 87 6

03H

-0.17 0.48 03H 03H PTP 0.19 38 6

STH 1.14 STH STH PTP 0.95 33 5

STH 0.99 STH STH MAI 0.92 114 2

02H

-0.03 0.53 02H 02H PTP 0.47 43 6

STH 1.46 STH STH DNG 6.39 178 1

01H 3.42 TEH TEC SAI 0.76 18 6

01H 3.22 0.49 01H 02H MAI 0.40 88 6

01H 0.06 0.28 01H 01H PTP 0.88 57 6

STH 1.00 STH STH PTP 0.47 97 6

STH 1.02 STH STH DSI 2.26 68 P1 03H

-0.02 TEH TEC MAI 0.46 82 6

03H

-0.07 0.43 03H 03H SAI 0.72 16 6

TSH

-4.68 0.25 TSH TSH PTP 0.60 72 6

STH 1.06 STH STH DSI 2.07 100 P1 01H

-0.05 TEH TEC SAI 0.91 98 6

01H 0.10 0.38 01H 01H MAI 0.16 105 6

03H

-0.08 0.57 03H 03H SVI 2.98 18 2

07H 3.03 0.39 62 07C 07H SAI 0.22 121 6

03H

-0.01 0.20 03H 03H SCI 0.14 96 P2 TSH 0.17 84 TSH TSH MAI 0.44 88 6

01H

-0.13 0.33 01H 01H SCI 0.29 41 P2 TSH

-0.03 87 TSH TSH SAI 0.56 109 6

02H

-0.10 0.42 02H 02H SAI 0.47 108 6

02H

-0.09 0.37 02H 02H SAI 0.27 103 6

04H 0.00 0.32 04H 04H SAI 0.43 90 6

01H 0.12 0.29 01H 01H SAI 0.83 15 6

TSH

-0.25 0.36 TSH TSH PCT 1.51 109 43 P1 02C 0.02 TEH TEC

ATTACHMENT 3 BEAVER VALLEY UNIT #1 IR15 S/G EXAMINATION RESULTS IRC-E-IC TUBES WITH INDICATIONS

Beaver Valley Unit #1 1 R1 5 S/G Examination Results 1 RC-E-1 C (TUBES WITH INDICATIONS)

Page 1 of 28 Row Col 1

17 1

45 1

45 1

45 1

45 1

45 1

47 1

47 1

47 1

73 1

85 1

85 1

87 1

87 1

90 1

90 1

93 1

93 1

94 1

94 1

94 2

3 2

6 2

6 2

6 2

6 2

7 2

7 2

7 2

8 2

8 2

8 2

8 2

10 2

10 2

11 2

11 2

11 2

12 2

12 2

12 2

13 2

13 2

14 2

14 2

15 2

15 2

15 2

17 2

17 2

18 Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To DSI 0.33 30 P1 06H

-0.03 07H TEH DSI 2.25 60 P1 01H 0.00 07H TEH MAI 0.44 79 6

01H 0.11 0.36 01H 01H DSI 0.93 65 P1 02H

-0.03 07H TEH DSI 0.62 119 P1 03H

-0.17 07H TEH SAI 0.31 126 6

03H

-0.06 0.26 03H 03H DSI 1.03 37 P1 01H 0.06 07H TEH MAI 0.40 86 6

01H 0.06 0.25 01H 01H DSI 1.24 83 P1 02H 0.00 07H TEH SAI 0.53 14 6

TSH

-0.31 0.30 TSH TSH DSI 0.51 112 P1 04H

-0.31 07H TEH DSI 0.67 32 P1 05H 0.00 07H TEH DSI 0.76 37 P1 02H

-0.06 07H TEH SAI 0.13 58 6

02H

-0.06 0.22 02H 02H DSI 1.13 35 P1 02H

-0.03 07H TEH SAI 0.36 85 6

02H

-0.03 0.43 02H 02H DSI 1.37 39 P1 02H

-0.06 07H TEH DSI 0.52 58 P1 05H 0.00 07H TEH DSI 0.55 57 P1 02H

-0.06 07H TEH DSI 0.81 37 P1 03H

-0.06 07H TEH SAI 0.20 98 6

03H

-0.06 0.24 03H 03H DSI 0.78 80 P1 04H

-0.06 07H TEH DSI 1.49 39 P1 01H

-0.03 07H TEH MAI 0.23 47 6

01H 0.10 0.29 01H 01H DS0 1.00 73 P1 02H

-0.11 07H TEH DSI 0.82 44 P1 03H

-0.03 07H TEH DSI 1.25 67 P1 01H

-0.09 07H TEH DSI 1.57 73 P1 02H 0.00 07H TEH DSI 1.31 63 P1 03H

-0.09 07H TEH DSI 0.83 96 P1 01H

-0.18 07H TEH MAI 0.32 101 6

O1H

-0.03 0.39 01H 01H DSI 0.69 76 P1 02H

-0.12 07H TEH DSI 0.84 54 P1 03H

-0.03 07H TEH DSI 1.08 55 P1 01H

-0.06 07H TEH DSI 1.27 65 P1 03H 0.00 07H TEH DSI 1.67 42 P1 01H 0.00 07H TEH DSI 1.06 61 P1 02H

-0.09 07H TEH DSI 0.56 98 P1 03H

-0.15 07H TEH DSI 1.43 46 P1 01H 0.00 07H TEH SAI 0.24 83 6

01H 0.06 0.32 01H 01H DSI 0.56 47 P1 02H

-0.06 07H TEH DSI 1.05 83 P1 01H

-0.11 07H TEH DSI 0.68 47 P1 03H

-0.03 07H TEH DSI 0.59 63 P1 01H

-0.03 07H TEH DSI 0.42 81 P1 02H 0.14 07H TEH DSI 1.14 39 P1 01H 0.06 07H TEH DSI 1.27 57 P1 02H

-0.09 07H TEH DSI 0.64 67 P1 03H

-0.11 07H TEH DSI 1.31 82 P1 01H

-0.14 07H TEH DSI 1.43 72 P1 02H

-0.14 07H TEH DSI 0.90 70 P1 01H

-0.06 07H TEH

Beaver Valley Unit #1 Page 2 of 28 1 R15 S/G Examination Results 1RC-E-1C (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 2

18 MAI 0.26 99 6

01H 0.01 0.39 01H 01H 2

18 DSI 1.12 71 P1 02H

-0.08 07H TEH 2

18 DSI 0.77 77 P1 03H

-0.09 07H TEH 2

19 DSI 1.18 73 P1 01H

-0.03 07H TEH 2

19 DSI 0.84 78 P1 02H 0.11 07H TEH 2

19 DSI 0.69 64 P1 03H

-0.11 07H TEH 2

20 DSI 1.03 62 P1 01H

-0.03 07H TEH 2

20 MAI 0.21 93 6

01H 0.03 0.49 01H 01H 2

20 DSI 0.35 50 P1 02H 0.00 07H TEH 2

20 MAI 0.23 68 6

02H

-0.12 0.27 02H 02H 2

20 DSI 0.34 80 P1 03H

-0.09 07H TEH 2

23 DSI 1.24 61 P1 01H

-0.11 07H TEH 2

23 DSI 0.90 82 P1 02H

-0.17 07H TEH 2

25 DSI 1.40 69 P1 01H

-0.12 07H TEH 2

25 DSI 1.18 76 P1 02H

-0.09 07H TEH 2

25 MAI 0.23 68 6

02H

-0.07 0.42 02H 02H 2

26 DSI 1.18 40 P1 01H 0.03 07H TEH 2

26 MAI 0.13 85 6

01H 0.01 0.30 01H 01H 2

26 DSI 1.24 60 P1 02H

-0.06 07H TEH 2

26 DSI 0.67 125 P1 03H 0.09 07H TEH 2

28 DSI 1.29 53 P1 01H

-0.06 07H TEH 2

28 DSI 0.38 37 P1 02H 0.06 07H TEH 2

33 DSI 1.00 36 P1 01H

-0.06 07H TEH 2

33 DSI 0.42 118 P1 02H 0.14 07H TEH 2

37 DSI 0.36 85 P1 02H

-0.06 07H TEH 2

42 DSI 0.71 38 P1 01H

-0.06 07H TEH 2

42 SAI 0.28 74 6

01H

-0.09 0.35 01H 01H 2

44 DSI 0.61 120 P1 01H

-0.09 07H TEH 2

44 SAI 0.23 121 6

O1H 0.04 0.32 01H 01H 2

44 DSI 0.35 56 P1 02H 0.00 07H TEH 2

45 DSI 0.50 95 P1 02H

-0.08 07H TEH 2

46 DSI 0.77 64 P1 02H

-0.03 07H TEH 2

48 DSI 1.00 54 P1 01H 0.03 07H TEH 2

48 DSI 0.58 52 P1 02H

-0.03 07H TEH 2

49 DSI 2.04 64 P1 01H

-0.09 07H TEH 2

49 SAI 0.86 93 6

01H

-0.05 0.39 01H 01H 2

50 DSI 0.58 69 P1 02H

-0.09 07H TEH 2

50 MAI 0.42 91 6

02H

-0.09 0.43 02H 02H 2

51 DSI 1.61 61 P1 01H 0.06 07H TEH 2

51 SPR 1.66 73 P1 01H 0.00 07H TEH 2

51 MAI 0.29 109 6

01H

-0.01 0.35 01H 01H 2

54 DSI 1.14 64 P1 01H 0.00 07H TEH 2

54 DSI 0.95 50 P1 02H

-0.06 07H TEH 2

54 SAI 0.21 96 6

02H

-0.04 0.26 02H 02H 2

65 DSI 0.47 92 P1 02H

-0.03 07H TEH 2

75 DSI 0.44 65 P1 02H

-0.03 07H TEH 2

76 DSI 0.70 57 P1 02H

-0.06 07H TEH 2

87 DSI 0.40 109 P1 02H

-0.03 07H TEH 2

87 SAI 0.25 89 6

02H

-0.01 0.29 02H 02H 2

87 DSI 0.37 70 P1 06H

-0.03 07H TEH 2

89 DSI 0.89 98 P1 02H 0.09 07H TEH

Beaver Valley Unit #1 Page 3 of 28 1 R1 5 S/G Examination Results 1RC-E-1C (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 2

90 DSI 0.18 148 P1 03H 0.06 07H TEH 3

9 DSI 0.84 38 P1 03H

-0.09 07H TEH 3

9 SAI 0.36 91 6

03H

-0.07 0.20 03H 03H 3

11 DSI 0.82 56 P1 02H

-0.03 07H TEH 3

12 DSI 0.74 63 P1 01H

-0.06 07H TEH 3

12 DSI 0.74 61 P1 02H 0.00 07H TEH 3

12 DSI 0.94 69 P1 03H

-0.14 07H TEH 3

13 DSI 0.69 40 P1 01H 0.03 07H TEH 3

13 SAI 0.41 94 6

01H 0.04 0.39 O1H O1H 3

13 DSI 0.42 44 P1 02H 0.00 07H TEH 3

14 DSI 0.92 64 P1 01H

-0.03 07H TEH 3

14 DSI 1.36 63 P1 02H

-0.06 07H TEH 3

14 DSI 0.90 44 P1 03H

-0.03 07H TEH 3

16 DSI 1.01 85 P1 01H

-0.11 07H TEH 3

16 DSI 0.80 80 P1 02H

-0.14 07H TEH 3

16 MAI 0.23 109 6

02H

-0.13 0.39 02H 02H 3

17 DSI 0.77 46 P1 01H

-0.03 07H TEH 3

17 SAI 0.21 78 6

01H 0.07 0.37 01H 01H 3

17 DSI 0.52 68 P1 02H

-0.06 07H TEH 3

17 SAI 0.30 97 6

02H

-0.13 0.37 02H 02H 3

22 DSI 0.36 66 P1 02H

-0.03 07H TEH 3

23 DSI 0.82 88 P1 01H

-0.17 07H TEH 3

23 DSI 0.64 124 P1 02H

-0.17 07H TEH 3

26 DSI 1.51 92 P1 01H -0.14 07H TEH 3

26 DSI 0.63 108 P1 02H

-0.14 07H TEH 3

26 SAI 0.25 100 6

02H

-0.23 0.29 02H 02H 3

29 DSI 0.92 63 P1 02H

-0.06 07H TEH 3

29 DSI 0.42 43 P1 03H 0.00 07H TEH 3

32 DSI 0.88 78 P1 01H

-0.20 07H TEH 3

33 DSI 0.80 90 P1 01H

-0.06 07H TEH 3

36 DSI 1.57 56 P1 01H

-0.03 07H TEH 3

36 DSI 0.56 119 P1 02H

-0.09 07H TEH 3

37 DSI 0.64 54 P1 01H 0.03 07H TEH 3

37 DSI 0.50 23 P1 02H

-0.03 07H TEH 3

39 DSI 0.97 45 P1 01H 0.03 07H TEH 3

39 MAI 0.22 89 6

01H 0.01 0.27 01H 01H 3

43 DSI 0.27 94 P1 01H

-0.06 07H TEH 3

45 DSI 1.00 59 P1 01H 0.00 07H TEH 3

47 DSI 2.25 54 P1 01H 0.00 07H TEH 3

47 MAI 1.66 76 6

01H 0.07 0.58 01H 01H 3

47 DSI 0.86 50 P1 02H

-0.08 07H TEH 3

47 SAI 0.49 98 6

02H

-0.12 0.33 02H 02H 3

48 DSI 0.82 65 P1 01H -0.03 07H TEH 3

50 DSI 1.70 111 P1 01H

-0.17 07H TEH 3

50 DSI 0.89 92 P1 02H

-0.03 07H TEH 3

50 SAI 0.59 83 6

02H

-0.05 0.22 02H 02H 3

51 DSI 0.79 115 P1 01H -0.23 07H TEH 3

52 DSI 0.99 65 P1 01H

-0.06 07H TEH 3

53 DSI 1.10 66 P1 02H

-0.03 07H TEH 3

58 DSI 1.18 62 P1 01H 0.00 07H TEH 3

58 DSI 0.73 55 P1 02H

-0.03 07H TEH

Beaver Valley Unit #1 1 R1 5 S/G Examination Results IRC-E-1C (TUBES WITH INDICATIONS)

Page 4 of 28 Row Col 3

58 3

81 3

93 3

94 3

94 3

94 4

3 4

3 4

3 4

3 4

4 4

4 4

7 4

7 4

7 4

7 4

8 4

8 4

10 4

11 4

11 4

15 4

15 4

15 4

15 4

18 4

18 4

18 4

18 4

21 4

21 4

31 4

31 4

32 4

32 4

32 4

32 4

33 4

33 4

35 4

37 4

37 4

37 4

40 4

40 4

41 4

41 4

43 4

43 4

44 4

44 Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To DSI 0.29 74 P1 05H 0.00 07H TEH DSI 0.54 53 P1 02H

-0.03 07H TEH PCT 0.35 145 0

P1 01C -0.11 07C TEC PCT 0.94 128 5

P1 01C -0.16 07C TEC DSI 0.85 92 P1 02H

-0.26 07H TEH SAI 0.15 98 6

02H

-0.26 0.24 02H 02H DSI 1.14 55 P1 01H

-0.03 07H TEH DSI 1.00 81 P1 02H 0.00 07H TEH MAI 0.38 90 6

02H 0.01 0.46 02H 02H DSI 1.37 93 P1 03H

-0.11 07H TEH DSI 0.79 28 P1 01H

-0.06 07H TEH MAI 0.17 90 6

01H 0.00 0.37 01H 01H DSI 1.17 39 P1 02H

-0.03 07H TEH MAI 0.23 86 6

02H 0.06 0.63 02H 02H DSI 0.75 37 P1 03H 0.09 07H TEH SAI 0.27 92 6

03H 0.14 0.34 03H 03H DSI 1.21 37 P1 01H

-0.06 07H TEH MAI 0.47 103 6

01H

-0.06 0.34 01H 01H DSI 0.60 43 P1 01H

-0.09 07H TEH DSI 1.11 22 P1 01H 0.00 07H TEH SAI 0.30 110 6

01H 0.04 0.34 01H 01H DSI 1.25 15 P1 01H 0.03 07H TEH MAI 0.15 80 6

01H 0.00 0.37 01H 01H DSI 1.04 20 P1 02H 0.00 07H TEH MAI 0.24 98 6

02H 0.00 0.20 02H 02H DSI 0.90 33 P1 01H

-0.03 07H TEH MAI 0.11 73 6

01H 0.08 0.32 01H 01H DSI 0.68 28 P1 02H

-0.06 07H TEH SAI 0.25 104 6

02H 0.06 0.29 02H 02H DSI 0.77 44 P1 02H

-0.06 07H TEH MAI 0.41 84 6

02H

-0.05 0.32 02H 02H DSI 0.93 37 P1 01H

-0.06 07H TEH SAI 0.24 113 6

01H 0.00 0.32 01H 01H DSI 0.92 51 P1 01H 0.00 07H TEH DSI 0.78 38 P1 02H

-0.17 07H TEH DSI 0.74 25 P1 03H

-0.03 07H TEH DSI 0.28 62 P1 04H

-0.03 07H TEH DSI 1.32 34 P1 01H

-0.06 07H TEH SAI 0.25 102 6

01H

-0.01 0.23 01H 01H DSI 1.04 51 P1 01H

-0.11 07H TEH DSI 1.60 23 P1 01H 0.00 07H TEH SAI 0.25 76 6

01H 0.04 0.28 01H 01H DSI 0.76 90 P1 02H

-0.17 07H TEH DSI 0.62 131 P1 01H

-0.11 07H TEH DSI 0.81 39 P1 02H

-0.03 07H TEH DSI 0.36 75 P1 01H 0.06 07H TEH DSI 0.62 31 P1 02H

-0.03 07H TEH DSI 1.23 50 P1 01H 0.00 07H TEH MAI 0.28 93 6

01H 0.07 0.33 01H 01H DSI 1.75 71 P1 01H 0.00 07H TEH MAI 0.60 88 6

01H

-0.01 0.46 01H O1H

Beaver Valley Unit #1 Page 5 of 28 1 R15 S/G Examination Results 1 RC-E-1 C (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 4

44 DSI 0.69 47 P1 02H 0.03 07H TEH 4

45 DSI 0.98 36 P1 01H

-0.06 07H TEH 4

45 MAI 0.39 97 6

01H

-0.06 0.48 01H 01H 4

48 DSI 0.81 43 P1 01H

-0.06 07H TEH 4

48 SAI 0.21 78 6

01H

-0.05 0.18 01H 01H 4

50 DSI 0.98 63 P1 01H 0.09 07H TEH 4

50 DSI 0.58 88 P1 02H 0.00 07H TEH 4

59 DSI 0.66 118 P1 01H 0.03 07H TEH 4

60 DSI 0.66 67 P1 O1H

-0.03 07H TEH 4

60 DSI 0.31 73 P1 02H 0.03 07H TEH 4

60 DSI 0.59 77 P1 03H 0.06 07H TEH 4

61 DSI 0.85 54 P1 01H

-0.03 07H TEH 4

65 DSI 0.48 79 P1 04H 0.03 07H TEH 4

65 DSI 0.35 62 P1 05H 0.03 07H TEH 4

73 DSI 0.50 54 P1 01H

-0.06 07H TEH 4

94 DSI 1.23 29 P1 02H

-0.03 07H TEH 4

94 DSI 0.66 42 P1 03H

-0.03 07H TEH 5

4 DSI 0.77 36 P1 01H 0.06 TEH TEC 5

4 SAI 0.14 82 6

01H 0.00 0.29 01H 01H 5

25 DSI 1.65 53 P1 01H 0.03 TEH TEC 5

25 DSI 0.83 49 P1 02H 0.06 TEH TEC 5

25 SAI 0.22 58 6

02H

-0.04 0.17 02H 02H 5

26 DSI 0.96 58 P1 01H 0.06 TEH TEC 5

27 DSI 0.80 43 P1 02H 0.08 TEH TEC 5

27 SAI 0.22 94 6

02H

-0.11 0.34 02H 02H 5

28 DSI 0.89 104 P1 01H 0.06 TEH TEC 5

28 DSI 0.64 85 P1 02H 0.03 TEH TEC 5

29 DSt 0.85 69 P1 02H 0.00 TEH TEC 5

29 MAI 0.26 88 6

02H

-0.02 0.32 02H 02H 5

43 DSI 0.48 139 P1 06H

-0.11 07H TEH 5

43 DSI 0.54 138 P1 06H

-0.14 07H TEH 5

48 DSI 0.92 81 P1 01H 0.06 07H TEH 5

48 DSI 0.76 83 P1 02H

-0.09 07H TEH 5

48 MAI 0.16 91 6

02H 0.06 0.35 02H 02H 5

49 DSI 1.46 89 P1 01H 0.06 07H TEH 5

50 DSI 0.70 94 P1 01H 0.03 07H TEH 5

51 DSI 0.80 91 P1 01H 0.06 07H TEH 5

51 DSI 0.41 116 P1 02H 0.06 07H TEH 5

51 SAI 0.38 92 6

02H 0.13 0.15 02H 02H 5

52 DSI 0.69 65 P1 01H 0.03 07H TEH 5

54 DSI 0.98 95 P1 01H 0.03 07H TEH 5

54 SAI 0.31 93 6

01H 0.00 0.34 01H 02H 5

55 DSI 0.63 79 P1 01H 0.06 07H TEH 5

57 DSI 0.88 52 P1 01H

-0.03 07H TEH 5

58 DSI 0.63 66 P1 01H 0.03 07H TEH 5

60 DSI 1.71 74 P1 01H

-0.03 07H TEH 5

60 DSI 0.29 27 P1 04H 0.06 07H TEH 5

61 DSI 0.72 67 P1 01H 0.00 07H TEH 5

61 DSI 0.71 62 P1 02H

-0.09 07H TEH 5

61 DSI 0.38 93 P1 03H 0.00 07H TEH 5

62 DSI 0.61 45 P1 01H 0.11 TEH TEC

Beaver Valley Unit #1 Page 6 of 28 1 R1 5 S/G Examination Results 1 RC-E-1 C (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 5

62 SAI 0.17 99 6

01H

-0.06 01H 01H 5

63 DSI 0.46 118 P1 02C 0.05 TEH TEC 5

64 DSI 0.70 88 P1 01H 0.00 TEH TEC 5

64 MAI 0.50 76 6

01H 0.00 0.57 01H 01H 5

64 DSI 0.67 102 P1 04H 0.03 TEH TEC 5

65 DSI 0.57 55 P1 02H 0.08 TEH TEC 5

67 DSI 0.79 30 P1 01H 0.14 TEH TEC 5

67 SAI 0.23 109 6

01H 0.14 0.19 01H 01H 5

67 DSI 0.21 106 P1 04H 0.05 TEH TEC 5

73 DSI 0.90 96 P1 01H 0.08 TEH TEC 5

81 DSI 0.49 52 P1 01H 0.06 TEH TEC 5

84 DSI 0.19 61 P1 03H 0.06 TEH TEC 6

8 DSI 0.63 33 P1 02H

-0.03 07H TEH 6

8 MAI 0.25

- 95 6

02H

-0.01 0.33 02H 02H 6

31 DSI 1.00 93 P1 01H 0.03 07H TEH 6

31 DSI 1.01 122 P1 02H

-0.11 07H TEH 6

33 DSI 1.00 89 P1 01H 0.00 07H TEH 6

33 DSI 0.60 121 P1 02H

-0.11 07H TEH 6

33 SAI 0.59 95 6

02H

-0.10 0.41 02H 02H 6

33 DSI 0.68 86 P1 03H 0.00 07H TEH 6

33 SAI 0.31 85 6

03H

-0.05 0.31 03H 03H 6

36 DSI 1.35 31 P1 01H

-0.09 07H TEH 6

36 DSI 0.86 81 P1 02H

-0.20 07H TEH 6

36 DSI 0.13 73 P1 05H

-0.03 07H TEH 6

38 DSI 0.75 102 P1 01H 0.06 07H TEH 6

38 DSI 0.58 71 P1 02H 0.00 07H TEH 6

38 SAI 0.32 103 6

02H 0.00 0.56 02H 02H 6

41 DSI 1.04 59 P1 01H 0.03 07H TEH 6

41 DSI 0.36 73 P1 02H

-0.06 07H TEH 6

43 DSI 1.11 70 P1 01H 0.03 07H TEH 6

43 DSI 1.10 72 P1 O1H 0.00 07H TEH 6

59 DSI 1.06 24 P1 01H 0.03 07H TEH 6

59 MAI 0.36 92 6

01H 0.00 0.29 01H 01H 6

64 DSI 0.47 75 P1 01H 0.05 TEH TEC 6

71 DSI 0.16 85 P1 04H 0.03 TEH TEC 6

77 DSI 0.39 99 P1 07H 0.06 TEH TEC 6

78 DSI 0.39 143 P1 01H 0.13 TEH TEC 6

79 DSI 0.76 101 P1 01H 0.06 TEH TEC 6

79 SAI 0.60 96 6

01H 0.06 0.46 01H 01H 6

81 DSI 1.25 100 P1 01H 0.19 TEH TEC 6

81 DSI 0.92 59 P1 02H 0.03 TEH TEC 6

81 DSI 1.25 51 P1 03H 0.06 TEH TEC 6

81 DSI 1.22 78 P1 04H 0.03 TEH TEC 6

82 DSI 0.60 114 P1 01H 0.06 TEH TEC 6

82 DSI 0.49 37 P1 02H 0.11 TEH TEC 6

82 SAI 0.22 60 6

02H 0.00 0.22 02H 02H 6

92 PCT 0.64 118 33 P1 0IC

-0.25 07C TEC 6

94 PCT 1.03 130 1

P1 01C

-0.11 07C TEC 6

94 VOL 0.26 105 3

01C 0.02 01C 01C 7

4 DSI 0.34 85 P1 o1H 0.00 TEH TEC 7

4 DSI 1.38 89 P1 02H 0.08 TEH TEC

Beaver Valley Unit #1 Page 7 of 28 1 R1 5 S/G Examination Results 1 RC-E-1C (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 7

5 DSI 0.73 101 P1 01H

-0.11 TEH TEC 7

6 DSI 0.37 132 P1 05H 0.17 TEH TEC 7

11 DSI 1.27 98 P1 01H 0.00 TEH TEC 7

11 DSI 1.00 71 P1 03H

-0.06 TEH TEC 7

18 DSI 0.75 45 P1 01H 0.11 TEH TEC 7

18 MAI 0.29 90 6

01H

-0.08 0.39 01H 01H 7

18 DSI 0.63 99 P1 02H

-0.03 TEH TEC 7

18 SAI 0.44 98 6

02H 0.00 0.41 02H 02H 7

19 DSI 1.11 101 P1 01H 0.03 TEH TEC 7

19 DSI 0.28 83 P1 02H 0.11 TEH TEC 7

29 SAI 0.53 23 6

TSH

-0.28 0.24 TSH TSH 7

30 DSI 1.18 29 P1 01H

-0.03 07H TEH 7

30 MAI 0.30 89 6

01H

-0.06 0.32 01H 01H 7

41 DSI 1.62 100 P1 01H

-0.09 07H TEH 7

41 SAI 0.43 84 6

01H

-0.12 0.45 01H 01H 7

41 DSI 0.68 128 P1 02H

-0.21 07H TEH 7

41 DSI 0.49 97 P1 03H

-0.03 07H TEH 7

46 DSI 0.80 110 P1 01H

-0.24 07H TEH 7

46 DSI 2.24 77 P1 02H 0.06 07H TEH 7

46 MAI 0.42 84 6

02H 0.06 0.50 02H 02H 7

46 DSI 1.08 93 P1 03H

-0.18 07H TEH 7

61 DSI 0.48 92 P1 03H

-0.17 07H TEH 7

65 DSI 0.74 44 P1 01H 0.00 07C TEH 7

65 MAI 0.19 80 6

01H 0.00 0.33 01H 01H 7

66 DSI 0.91 54 P1 01H

-0.11 07H TEH 7

66 DSI 0.54 39 P1 02H

-0.09 07H TEH 7

67 DSI 0.35 86 P1 04C 0.00 07C TEC 7

67 SVI 0.20 119 P2 07H 0.26 0.29 63 07C 07H 7

68 DSI 1.09 44 P1 01H

-0.03 07H TEH 7

68 MAI 0.23 84 6

01H

-0.12 0.38 01H 01H 7

69 DSI 0.40 32 P1 02H

-0.03 07H TEH 7

70 DSI 1.46 56 P1 02H 0.00 07H TEH 7

71 DSI 1.35 36 P1 01H

-0.03 07H TEH 7

71 MAI 0.21 105 6

01H

-0.03 0.22 01H 01H 7

90 DSI 1.65 86 P1 02H 0.14 TEH TEC 7

91 DSI 0.75 61 P1 01H 0.14 TEH TEC 7

92 DSI 0.73 78 P1 02H 0.11 TEH TEC 7

92 DSI 1.41 80 P1 03H 0.14 TEH TEC 7

92 SAI 0.31 96 6

03H 0.14 0.22 03H 03H 7

93 DSI 0.43 127 P1 01H 0.08 TEH TEC 7

93 DSI 0.51 77 P1 04H 0.05 TEH TEC 7

93 SAI 0.33 100 6

04H 0.00 0.27 04H 04H 7

94 PCT 0.47 149 0

P1 01C

-0.13 TEH TEC 7

94 DSI 0.87 86 P1 02H 0.13 TEH TEC 7

94 DSI 0.79 57 P1 03H 0.08 TEH TEC 8

11 DSI 0.94 26 P1 01H 0.00 07H TEH 8

11 SAI 0.17 107 6

01H 0.08 0.24 01H 01H 8

13 DSI 0.73 29 P1 01H 0.08 TEH TEC 8

13 MAI 0.13 89 6

01H 0.00 0.34 O1H 01H 8

16 DSI 0.34 49 P1 03H

-0.03 07H TEH 8

29 SAI 0.25 84 6

TSH 0.23 0.30 TSH TSH

Beaver Valley Unit #1 Page 8 of 28 1 R1 5 S/G Examination Results 1RC-E-1C (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 8

38 DSI 0.85 76 P1 01H

-0.06 07H TEH 8

74 DSI 0.10 24 P1 01H 0.11 TEH TEC 8

77 DSI 0.52 108 P1 02H 0.00 TEH TEC 8

81 DSI 0.89 44 P1 01H 0.06 TEH TEC 8

81 SAI 0.49 107 6

01H 0.00 0.41 01H 01H 9

2 DSI 0.50 151 P1 03H 0.00 TEH TEC 9

4 DSI 0.66 99 P1 01H 0.24 TEH TEC 9

4 DSI 0.44 50 P1 02H 0.00 TEH TEC 9

5 DSI 0.62 71 P1 01H

-0.11 TEH TEC 9

8 DSI 1.57 72 P1 01H 0.05 TEH TEC 9

8 DSI 0.39 52 P1 02H 0.11 TEH TEC 9

8 SAI 0.20 78 6

02H

-0.01 0.26 02H 02H 9

10 DSI 1.49 56 P1 01H 0.03 TEH TEC 9

10 SPR 1.72 54 P1 02H 0.00 TEH TEC 9

10 DSI 1.47 57 P1 02H

-0.11 TEH TEC 9

10 SAI 0.23 69 6

02H

-0.02 0.24 02H 02H 9

10 DSI 1.03 57 P1 03H 0.06 TEH TEC 9

10 DSI 0.74 73 P1 04H 0.03 TEH TEC 9

14 DSI 0.84 61 P1 01H 0.08 TEH TEC 9

15 DSI - 0.29 67 P1 01H 0.00 TEH TEC 9

33 SAI 0.16 84 6

TSH 0.52 0.44 TSH TSH 9

33 SAI 0.12 101 6

TSH 0.89 0.20 TSH TSH 9

35 DSI 0.82 27 P1 01H 0.03 TEH TEC 9

39 DSI 0.51 36 P1 01H 0.00 07H TEH 9

76 DSI 0.47 110 P1 06H

-0.03 TEH TEC 9

79 DSI 0.45 27 P1 03H

-0.03 TEH TEC 9

79 DSI 0.32 37 P1 05H 0.08 TEH TEC 9

85 DSI 0.70 40 P1 03H 0.03 TEH TEC 9

85 SAI 0.18 73 6

03H 0.03 0.30 03H 03H 9

86 DSI 0.24 83 P1 02H 0.11 TEH TEC 9

88 DSI 0.20 90 P1 06H 0.00 TEH TEC 9

93 PCT 1.93 130 21 P1 01C -0.03 TEH TEC 10 2

PCT 0.46 130 6

P1 03C 0.19 TEH TEC 10 3

DSI 0.36 72 P1 01H 0.03 TEH TEC 10 9

DSI 0.59 34 P1 01H 0.03 TEH TEC 10 48 DSI 2.50 67 P1 01H 0.03 07H TEH 10 48 MAI 0.99 75 6

01H 0.03 0.37 01H 01H 10 49 DSI 0.66 76 P1 01H -0.11 07H TEH 10 54 DSI 1.06 82 P1 01H 0.00 07H TEH 10 54 SAI 0.57 85 6

01H 0.00 0.46 01H 01H 10 55 DSI 0.87 75 P1 01H 0.06 07H TEH 10 56 DSI 1.27 63 P1 01H 0.11 07H TEH 10 58 DSI 1.32 61 P1 01H 0.11 07H TEH 10 62 DSI 0.66 71 P1 01H 0.11 TEH TEC 10 62 DSI 0.78 56 P1 02H 0.08 TEH TEC 10 62 DSI 0.43 45 P1 03H 0.03 TEH TEC 10 65 DSI 1.65 87 P1 01H 0.03 TEH TEC 10 65 DSI 0.47 121 P1 02H 0.00 TEH TEC 10 66 DSI 1.90 66 P1 01H 0.11 TEH TEC 10 67 DSI 0.65 56 P1 01H 0.05 TEH TEC 10 68 DSI 1.67 105 P1 01H 0.05 TEH TEC

Beaver Valley Unit #1 Page 9 of 28 1 R1 5 S/G Examination Results 1 RC-E-1 C (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inchl Cr-Length Cr-Angle From To 10 69 DSI 0.85 60 P1 01H 0.16 TEH TEC 10 69 DSI 0.80 39 P1 02H 0.00 TEH TEC 10 69 MAI 0.39 100 6

02H 0.00 0.43 02H 02H 10 70 DSI 0.54 96 P1 02H

-0.14 TEH TEC 10 71 DSI 0.67 65 P1 01H 0.06 TEH TEC 11 33 MAI 0.15 88 6

TSH 1.06 0.32 TSH TSH 11 72 DSI 0.22 60 P1 06H 0.00 TEH TEC 11 93 DSI 0.40 126 P1 01H 0.11 TEH TEC 12 34 SAI 0.10 68 6

TSH 2.22 0.20 TSH TSH 12 34 SAI 0.18 83 6

TSH 1.60 0.46 TSH TSH 12 47 NOI 2.75 22 3

01C 1.28 TEH TEC 12 48 SPR 1.72 15 P1 01H 0.00 TEH TEC 12 48 DSI 1.33 10 P1 01H 0.03 TEH TEC 12 48 SAI 0.21 91 6

01H 0.09 0.30 01H 01H 12 50 DSI 0.70 48 P1 01H 0.16 TEH TEC 12 84 DSI 0.21 99 P1 02H 0.03 TEH TEC 12 93 PCT 1.19 123 23 P1 01C

-0.05 TEH TEC 12 93 VOL 0.28 96 3

01C 0.01 01C 01C 13 47 DSI 0.74 50 P1 01H 0.00 TEH TEC 13 47 MAI 0.41 101 6

01H

-0.12 0.48 01H 01H 13 60 DSI 0.36 97 P1 01H 0.00 TEH TEC 13 61 SAI 1.27 12 2

07H 19.93 3.11 07C 07H 13 63 DSI 0.35 77 P1 01H 0.06 TEH TEC 13 92 PCT 0.43 126 9

P1 01C

-0.03 TEH TEC 13 92 DSI 0.54 140 P1 01H 0.11 TEH TEC 14 12 DSI 0.37 98 P1 01H 0.14 TEH TEC 14 50 NOI 0.36 91 P1 TSH 0.52 TEH TEC 14 52 SAI 0.21 83 6

TSH 0.55 0.61 TSH TSH 14 69 DSI 0.29 126 P1 03H 0.08 TEH TEC 14 92 DSI 0.76 128 P1 01H 0.03 TEH TEC 15 4

PCT 0.54 123 21 P1 02C 0.11 TEH TEC 15 4

VOL 0.41 121 3

02C 0.09 02C 02C 15 8

DSI 0.91 60 P1 01H 0.08 TEH TEC 15 8

DSI 0.92 48 P1 02H 0.06 TEH TEC 15 8

MAI 0.22 74 6

02H 0.01 0.32 02H 02H 15 16 DSI 0.39 66 P1 01H 0.00 TEH TEC 15 52 DSI 1.08 58 P1 01H 0.00 TEH TEC 15 52 DSI 1.31 70 P1 02H 0.16 TEH TEC 15 52 SAI 0.22 109 6

02H 0.02 0.38 02H 02H 15 52 DSI 0.49 117 P1 03H 0.17 TEH TEC 15 53 DSI 1.20 85 P1 011H 0.06 TEH TEC 15 53 DSI 0.58 85 P1 02H 0.17 TEH TEC 15 53 DSt 1.30 82 P1 03H

-0.08 TEH TEC 15 56 DSI 0.78 89 P1 01H 0.16 TEH TEC 15 56 DSI 1.34 104 P1 02H

-0.08 TEH TEC 15 58 DSI 0.56 62 P1 01H 0.11 TEH TEC 15 58 DSI 0.23 133 P1 03H 0.06 TEH TEC 15 63 DSI 1.58 85 P1 01H 0.11 TEH TEC 15 63 DSI 1.12 75 P1 02H

-0.19 TEH TEC 15 63 DSI 0.85 85 P1 03H 0.11 TEH TEC 15 63 SAI 0.37 98 6

03H 0.04 0.27 03H 03H

Beaver Valley Unit #1 Page 10 of 28 1 R1 5 S/G Examination Results 1 RC-E-1 C (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 15 63 DSI 0.74 90 P1 04H

-0.20 TEH TEC 15 91 PCT 1.65 120 33 P1 01C

-0.06 TEH TEC 16 4

PCT 0.76 116 31 P1 02C 0.06 TEH TEC 16 17 DSI 0.12 105 P1 04H 0.08 TEH TEC 16 50 DSI 0.22 86 P1 02H 0.08 TEH TEC 16 51 DSI 0.71 52 P1 01H 0.08 TEH TEC 16 90 PCT 1.58 123 15 P1 01C

-0.08 TEH TEC 17 10 DSI 0.91 127 P1 01H

-0.08 TEH TEC 17 10 DSI 0.57 71 P1 03H

-0.03 TEH TEC 17 10 SAI 0.22 69 6

03H

-0.07 0.17 03H 03H 17 15 DSI 0.29 31 P1 01H 0.08 TEH TEC 17 16 DSI 0.88 38 P1 01H

-0.03 TEH TEC 17 16 SAI 0.20 95 6

01H

-0.05 0.37 01H 01H 17 17 DSI 0.47 43 P1 01H 0.03 TEH TEC 17 17 DSI 0.68 86 P1 02H

-0.11 TEH TEC 17 17 DSI 0.98 31 P1 03H 0.00 TEH TEC 17 18 DSI 0.67 46 P1 01H 0.03 TEH TEC 17 18 SAI 0.14 120 6

01H

-0.09 0.22 01H 01H 17 20 DSI 0.28 110 P1 05H 0.03 TEH TEC 17 22 SAI 0.64 10 2

07H 4.74 0.25 07C 07H 17 80 DSI 0.80 119 P1 01H

-0.06 TEH TEC 17 81 DSI 0.29 128 P1 02H 0.03 TEH TEC 17 82 DSI 0.21 58 P1 02H 0.00 TEH TEC 17 84 DSI 0.49 50 P1 02H 0.00 TEH TEC 17 84 DSI 0.25 127 P1 05H 0.08 TEH TEC 17 85 DSI 0.69 112 P1 02H

-0.13 TEH TEC 17 89 PCT 1.12 123 18 P1 01C

-0.19 TEH TEC 18 19 DSI 0.91 70 P1 01H 0.00 TEH TEC 18 19 DSI 0.92 99 P1 02H

-0.11 TEH TEC 18 19 DSI 0.78 121 P1 03H

-0.11 TEH TEC 18 22 DSI 1.05 84 P1 011H 0.00 TEH TEC 18 22 DSI 0.33 137 P1 04C 0.00 TEH TEC 18 43 DSI 0.46 80 P1 01H 0.08 TEH TEC 18 51 DSI 0.35 55 P1 02H 0.11 TEH TEC 18 71 DSI 0.69 46 P1 01H 0.14 TEH TEC 18 73 DSI 0.66 59 P1 02H 0.00 TEH TEC 18 73 DSI 0.60 130 P1 06H 0.14 TEH TEC 19 6

DSI 0.74 81 P1 01H 0.08 TEH TEC 19 65 DSI 0.32 156 P1 05H 0.06 TEH TEC 19 90 PCT 0.90 134 5

P1 01C

-0.22 TEH TEC 20 44 DSI 1.13 130 P1 01H

-0.08 TEH TEC 20 71 DSI 0.56 36 P1 02H 0.06 TEH TEC 20 72 DSI 0.43 98 P1 01H 0.06 TEH TEC 20 72 DSI 0.97 45 P1 02H 0.06 TEH TEC 20 72 SAI 0.33 109 6

02H 0.12 0.22 02H 02H 20 73 DSI 0.76 125 P1 01H

-0.05 TEH TEC 20 73 MAI 0.17 135 6

01H 0.03 0.18 TSH 01H 20 73 DSI 0.79 143 P1 03H 0.14 TEH TEC 20 73 DSI 0.65 129 P1 06H 0.00 TEH TEC 20 75 DSI 1.17 83 P1 01H 0.14 TEH TEC 20 85 DSI 0.57 107 P1 01H 0.13 TEH TEC

Beaver Valley Unit #1 Page 11 of 28 1 R1 5 S/G Examination Results 1RC-E-1C (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 21 22 DSI 1.81 94 P1 01H 0.03 TEH TEC 21 22 DSI 1.23 103 P1 02H 0.14 TEH TEC 21 39 DSI 0.54 30 P1 01H 0.03 TEH TEC 21 42 DSI 0.43 60 P1 01H 0.08 TEH TEC 21 88 PCT 0.54 147 0

P1 01C -0.19 TEH TEC 22 9

DSI 0.73 124 P1 01H

-0.06 TEH TEC 22 87 PCT 0.39 134 11 P1 01C

-0.11 TEH TEC 23 9

DSI 0.64 87 P1 01H 0.11 TEH TEC 23 9

DSI 0.87 127 P1 02H 0.11 TEH TEC 23 9

SAI 0.61 97 6

02H 0.10 0.20 02H 02H 23 12 DSI 1.66 93 P1 01H

-0.05 TEH TEC 23 15 DSI 1.69 91 P1 01H 0.16 TEH TEC 23 15 DSI 1.32 106 P1 02H 0.00 TEH TEC 23 15 DSI 0.67 127 P1 03H 0.14 TEH TEC 23 25 DSI 0.79 70 P1 01H 0.06 TEH TEC 23 25 DSI 0.45 51 P1 02H 0.06 TEH TEC 23 26 DSI 0.32 72 P1 01H

-0.06 TEH TEC 23 26 DSI 0.42 138 P1 02H

-0.17 TEH TEC 23 27 DSI 0.71 95 P1 01H 0.00 TEH TEC 23 27 DSI 0.56 147 P1 03H 0.06 TEH TEC 23 31 DSI 0.62 94 P1 01H 0.06 TEH TEC 23 32 DSI 0.85 94 P1 01H 0.08 TEH TEC 23 32 NQI 0.51 118 3

06C 43.32 TEH TEC 23 36 DSI 0.87 43 P1 01H 0.11 TEH TEC 23 36 SAI 0.34 106 6

01H 0.02 0.62 01H 01H 23 36 DSI 0.44 130 P1 02H 0.14 TEH TEC 23 38 DSI 0.35 80 P1 01H 0.05 TEH TEC 23 38 DSI 0.44 52 P1 02H

-0.03 TEH TEC 23 39 DSI 0.41 47 P1 02H 0.03 TEH TEC 23 42 DSI 0.41 98 P1 01H 0.14 TEH TEC 23 42 DSI 0.48 48 P1 02H

-0.03 TEH TEC 23 49 SAI 0.56 17 6

TSH

-0.49 0.20 TSH TSH 23 50 DSI 1.18 93 P1 01H 0.08 TEH TEC 23 50 DSI 1.15 125 P1 02H

-0.08 TEH TEC 23 61 DSI 0.36 89 P1 02H 0.00 TEH TEC 23 62 DSI 0.44 97 P1 01H 0.03 TEH TEC 23 62 NOI 0.47 115 3

TSC 30.86 TEH TEC 23 62 NOI 0.37 103 3

TSC 44.07 TEH TEC 23 62 NOI 0.60 113 3

TSC 40.90 TEH TEC 23 62 NOI 0.33 113 3

TSC 40.34 TEH TEC 23 65 DSI 0.86 159 P1 01H

-0.03 TEH TEC 23 65 DSI 1.34 97 P1 02H 0.00 TEH TEC 23 66 DSI 0.42 50 P1 01H 0.11 TEH TEC 23 70 DSI 0.78 69 P1 01H 0.08 TEH TEC 23 71 DSI 1.36 88 P1 01H 0.11 TEH TEC 23 71 DSI 0.65 86 P1 02H 0.03 TEH TEC 23 73 DSI 0.85 110 P1 01H 0.14 TEH TEC 23 73 DSI 0.58 69 P1 02H 0.05 TEH TEC 23 74 DSI 0.39 48 P1 01H 0.08 TEH TEC 23 77 DSI 1.00 98 P1 01H 0.14 TEH TEC 23 77 SAI 0.85 95 6

01H 0.05 0.44 01H 01H

Beaver Valley Unit #1 Page 12 of 28 1 R15 S/G Examination Results 1 RC-E-1 C (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %/cTW Chan Loc Inchl Cr-Length Cr-Angle From To 23 77 DSI 0.55 69 P1 02H 0.08 TEH TEC 23 86 PCT 0.68 134 9

P1 01C 0.08 TEH TEC 23 88 NOI 0.28 111 3

01C 20.07 TEH TEC 23 88 NOI 0.37 121 3

TSC 42.91 TEH TEC 23 88 NOI 0.45 122 3

TSC 30.42 TEH TEC 24 8

DSI 0.45 119 P1 01H 0.11 TEH TEC 24 10 DSI 1.41 107 P1 01H

-0.13 TEH TEC 24 10 DSI 0.22 99 P1 03H 0.08 TEH TEC 24 13 DSI 1.25 96 P1 01H

-0.08 TEH TEC 24 16 DSI 0.38 37 P1 02H 0.06 TEH TEC 24 18 DSI 0.17 30 P1 02H 0.00 TEH TEC 24 21 DSI 0.60 124 P1 01H 0.00 TEH TEC 24 21 DSI 0.65 72 P1 02H 0.00 TEH TEC 24 21 MAI 0.33 108 6

02H 0.00 0.29 02H 02H 24 22 DSI 0.73 89 P1 02H

-0.06 TEH TEC 24 25 PCT 1.34 126 21 P2 AV3

-0.58 TEH TEC 24 25 WAR 0.38 111 2

AV3

-0.58 07C 07H 24 27 PCT 2.67 0

30 P2 AV2 0.27 TEH TEC 24 27 WAR 0.44 121 2

AV2 0.27 07C 07H 24 27 PCT 0.69 0

13 P2 AV3

-0.38 TEH TEC 24 27 WAR 0.27 127 2

AV3 0.37 07C 07H 24 31 DSI 0.62 103 P1 01H 0.03 TEH TEC 24 31 DSI 0.77 116 P1 02H

-0.14 TEH TEC 24 35 DSI 0.28 32 P1 01H 0.08 TEH TEC 24 36 DSI 0.34 27 P1 01H 0.06 TEH TEC 24 37 DSI 0.59 39 P1 02H 0.05 TEH TEC 24 40 DSI 0.67 47 P1 01 H 0.03 TEH TEC 24 40 MAI 0.14 92 6

01H

-0.02 0.33 01H 01H 24 42 DSI 0.49 44 P1 01H 0.05 TEH TEC 24 43 DSI 1.19 113 P1 01H

-0.05 TEH TEC 24 43 SAI 0.53 109 6

01H

-0.08 0.64 01H 01H 24 43 DSI 0.87 90 P1 03H 0.03 TEH TEC 24 45 DSI 0.25 60 P1 011H 0.00 TEH TEC 24 47 DSI 0.40 30 P1 01H 0.08 TEH TEC 24 57 SAI 0.20 85 6

TSH 0.00 0.16 TSH TSH 24 59 DSI 0.74 97 P1 01H 0.11 TEH TEC 24 59 SAI 0.39 102 6

01H

-0.01 0.57 TSH 01H 24 59 NOI 0.47 111 3

02H 28.32 TEH TEC 24 59 NOI 0.29 66 3

TSH 28.87 TEH TEC 24 62 DSI 0.82 120 P1 01H 0.00 TEH TEC 24 65 DSI 0.90 106 P1 01H 0.08 TEH TEC 24 65 DSI 0.27 46 P1 02H 0.08 TEH TEC 24 69 DSI 0.56 115 P1 01H 0.05 TEH TEC 24 69 DSI 0.67 87 P1 02H 0.00 TEH TEC 24 72 DSI 1.74 102 P1 01H 0.13 TEH TEC 24 72 DSI 0.82 73 P1 02H 0.05 TEH TEC 24 72 MAI 0.59 100 6

02H 0.10 0.44 02H 02H 24 74 DSI 1.16 122 P1 02H 0.08 TEH TEC 24 79 DSI 0.64 68 P1 01H 0.08 TEH TEC 24 79 MAI 0.27 103 6

01H

-0.10 0.71 TSH 01H 24 79 NOI 0.42 115 3

TSH 19.76 TEH TEC

Beaver Valley Unit #1 Page 13 of 28 1 R15 S/G Examination Results 1RC-E-1C (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 24 86 PCT 1.01 134 14 P1 01C

-0.17 TEH TEC 25 9

PCT 1.28 0

20 P2 AV2

-0.11 TEH TEC 25 9

WAR 0.22 119 P2 AV2 0.00 07H 07C 25 9

WAR 0.33 141 2

AV2 0.00 07C 07H 25 9

PCT 0.91 0

16 P2 AV3

-0.11 TEH TEC 25 9

WAR 0.14 117 P2 AV3 0.00 07H 07C 25 9

WAR 0.19 143 2

AV3 0.00 07C 07H 25 10 DS 10.99 107 P1 01H 0.03 TEH TEC 25 12 DSI 1.68 111 P1 01H

-0.05 TEH TEC 25 12 DSI 1.06 102 P1 02H

-0.11 TEH TEC 25 12 DSI 0.20 59 P1 05H 0.03 TEH TEC 25 13 DSI 0.26 85 P1 01H 0.03 TEH TEC 25 14 DSI 0.52 72 P1 01H

-0.03 TEH TEC 25 14 DSI 0.30 82 P1 02H 0.03 TEH TEC 25 17 DSI 0.37 66 P1 01H 0.00 TEH TEC 25 17 DSI 0.45 46 P1 02H 0.06 TEH TEC 25 18 DSI 0.52 46 P1 01H 0.00 TEH TEC 25 22 DSI 1.47 117 P1 01H

-0.08 TEH TEC 25 25 DSI 0.80 94 P1 O1H 0.08 TEH TEC 25 26 DSI 0.95 73 P1 01H 0.14 TEH TEC 25 29 DSI 0.48 74 P1 01H 0.03 TEH TEC 25 30 DSI 0.53 66 P1 01H 0.06 TEH TEC 25 32 DSI 1.25 128 P1 01H 0.06 TEH TEC 25 38 DSI 0.93 62 P1 01H 0.08 TEH TEC 25 41 DSI 0.52 45 P1 01H 0.05 TEH TEC 25 44 DSI 0.43 47 P1 02H 0.00 TEH TEC 25 45 DSI 0.61 78 P1 01H 0.11 TEH TEC 25 45 DSI 0.21 140 P1 02H 0.00 TEH TEC 25 46 DSI 0.82 62 P1 03H 0.03 TEH TEC 25 47 DSI 0.65 119 P1 02H

-0.17 TEH TEC 25 51 DSI 0.67 59 P1 01H 0.11 TEH TEC 25 60 DSI 0.63 54 P1 01H 0.03 TEH TEC 25 64 DSI 0.88 33 P1 02H 0.06 TEH TEC 25 64 SAI 0.45 84 6

02H

-0.08 0.32 02H 02H 25 64 DSI 0.53 151 P1 03H 0.06 TEH TEC 25 68 DSI 0.79 132 P1 01H

-0.11 TEH TEC 25 68 DSI 0.50 72 P1 02H 0.11 TEH TEC 25 68 SAI 0.38 88 6

02H 0.06 0.27 02H 02H 25 68 DSI 0.21 47 P1 03H 0.03 TEH TEC 25 69 DSI 0.88 94 P1 01H 0.06 TEH TEC 25 69 DSI 0.81 134 P1 02H

-0.06 TEH TEC 25 86 PCT 1.54 126 23 P1 01C

-0.14 TEH TEC 25 86 NQI 0.56 118 3

AV3 13.88 TEH TEC 26 9

DSI 0.57 83 P1 01H 0.06 TEH TEC 26 9

DSI 0.26 102 P1 02H 0.08 TEH TEC 26 11 DSI 0.30 88 P1 01H 0.08 TEH TEC 26 14 DSI 0.57 82 P1 01H 0.00 TEH TEC 26 18 DSI 0.41 56 P1 02H 0.00 TEH TEC 26 19 DSI 1.53 117 P1 01H

-0.08 TEH TEC 26 19 DSI 0.35 50 P1 02H 0.03 TEH TEC 26 20 DSI 1.96 111 P1 O1H

-0.06 TEH TEC

Beaver Valley Unit #1 1 R1 5 S/G Examination Results 1RC-E-1C (TUBES WITH INDICATIONS)

Page 14 of 28 Row Col 26 20 26 22 26 23 26 24 26 25 26 25 26 25 26 26 26 26 26 26 26 26 26 28 26 28 26 28 26 28 26 28 26 28 26 29 26 31 26 31 26 32 26 32 26 33 26 33 26 33 26 33 26 33 26 33 26 34 26 34 26 34 26 34 26 35 26 35 26 35 26 36 26 36 26 36 26 36 26 36 26 37 26 40 26 40 26 46 26 46 26 49 26 49 26 49 26 51 26 51 26 59 Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To DSI 0.86 103 P1 02H 0.06 TEH TEC DSI 0.72 61 P1 02H 0.00 TEH TEC DSI 1.41 90 P1 O1H 0.11 TEH TEC DSI 0.60 55 P1 01H 0.08 TEH TEC DSI 1.75 100 P1 01H

-0.08 TEH TEC DSI 0.89 84 P1 02H

-0.06 TEH TEC MAI 0.48 105 6

02H 0.00 0.46 02H 02H DSI 1.79 100 P1 01H

-0.03 TEH TEC DSI 0.58 74 P1 02H

-0.03 TEH TEC SAI 0.23 100 6

02H

-0.08 0.24 02H 02H DSI 0.57 71 P1 03H 0.03 TEH TEC DSI 1.39 119 P1 01H

-0.08 TEH TEC SAI 0.82 89 6

01H

-0.07 0.34 01H 01H DSI 0.68 109 P1 03H 0.00 TEH TEC NOI 0.32 91 3

04C 6.06 TEH TEC NOI 0.38 109 3

05H 2.85 TEH TEC NOI 0.25 12 P1 TSH 4.88 TEH TEC DSI 0.86 63 P1 01H 0.06 TEH TEC DSI 0.92 142 P1 01H

-0.11 TEH TEC DSI 0.31 55 P1 02H 0.00 TEH TEC DSI 1.01 71 P1 01H 0.06 TEH TEC DSI 0.07 35 P1 02H 0.03 TEH TEC DSI 0.98 123 P1 01H 0.00 TEH TEC DSI 0.96 84 P1 02H 0.08 TEH TEC MAI 0.42 100 6

02H 0.01 0.46 02H 02H DSI 0.28 71 P1 03H 0.03 TEH TEC DSI 0.81 114 P1 04H

-0.03 TEH TEC SAI 0.31 100 6

04H

-0.03 0.28 04H 04H DSI 1.56 118 P1 01H 0.00 TEH TEC DSI 0.59 113 P1 02H 0.00 TEH TEC DSI 0.74 82 P1 03H 0.06 TEH TEC DSI 0.62 144 P1 04H 0.03 TEH TEC DSI 0.37 67 P1 01H 0.03 TEH TEC DSI 1.03 66 P1 02H 0.03 TEH TEC DSI 0.50 38 P1 03H 0.00 TEH TEC DSI 0.67 49 P1 01H 0.06 TEH TEC SAI 0.36 104 6

01H

-0.01 0.37 01H 01H DSI 1.03 58 P1 02H 0.06 TEH TEC MAI 0.23 82 6

02H

-0.15 0.47 02H 02H DSI 0.33 42 P1 03H 0.03 TEH TEC DSI 0.85 68 P1 02H 0.08 TEH TEC DSI 0.75 77 P1 01H 0.14 TEH TEC DSI 0.52 76 P1 02H 0.08 TEH TEC DSI 0.54 82 P1 01H 0.00 TEH TEC DSI 0.72 94 P1 02H 0.22 TEH TEC DSI 1.65 89 P1 01H 0.14 TEH TEC DSI 0.23 90 P1 02H 0.11 TEH TEC SAI 0.29 103 6

02H 0.00 0.31 02H 02H DSI 0.87 72 P1 01H 0.06 TEH TEC MAI 0.50 97 6

01H

-0.02 0.46 01H 01H DSI 0.47 49 P1 01H 0.00 TEH TEC

Beaver Valley Unit #1 Page 15 of 28 1 R1 5 S/G Examination Results 1 RC-E-1 C (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 26 60 DSI 1.12 100 P1 01H 0.03 TEH TEC 26 60 DSI 0.28 97 P1 02H 0.05 TEH TEC 26 62 OBS 04C 04C 26 63 DSI 0.27 59 P1 02C 0.00 TEH TEC 26 67 DSI 0.68 70 P1 01H 0.08 TEH TEC 26 67 DSI 0.68 48 P1 02H 0.03 TEH TEC 26 67 SAI 0.40 92 6

02H

-0.20 0.51 02H 02H 26 70 DSI 0.45 128 P1 01H 0.14 TEH TEC 26 70 DSI 0.45 68 P1 02H 0.06 TEH TEC 26 72 DSI 0.41 30 P1 02H 0.03 TEH TEC 26 73 DSI 0.41 104 P1 011H 0.03 TEH TEC 26 74 DSI 0.55 101 P1 011H 0.08 TEH TEC 26 80 DNI 0.72 97 5

05C 24.01 TEH TEC 26 83 NOI 0.50 52 3

02C 43.43 TEH TEC 26 84 PCT 0.87 135 1

P1 01C

-0.14 TEH TEC 26 86 PCT 1.61 134 12 P1 01C

-0.23 TEH TEC 27 10 PCT 1.02 44 16 P2 AV2 0.03 TEH TEC 27 10 WAR 0.21 121 2

AV2 0.00 07H 07C 27 18 DSI 1.82 105 P1 01H 0.00 TEH TEC 27 18 MAI 0.59 83 6

01H

-0.07 0.51 01H 01H 27 19 DSI 1.07 28 P1 01H 0.05 TEH TEC 27 19 MAI 0.66 99 6

01H

-0.05 0.37 011H 01H 27 21 DSI 0.76 87 P1 01H 0.11 TEH TEC 27 21 DSI 0.73 55 P1 02H 0.08 TEH TEC 27 24 DSI 0.30 53 P1 01H 0.06 TEH TEC 27 26 PCT 0.81 0

15 P2 AV1 0.20 TEH TEC 27 26 WAR 0.18 118 2

AV1 0.00 07H 07C 27 26 PCT 3.27 0

32 P2 AV2

-0.06 TEH TEC 27 26 PCT 1.36 0

21 P2 AV2

-0.50 TEH TEC 27 26 WAR 0.53 123 2

AV2 0.00 07H 07C 27 26 WAR 0.31 138 2

AV2

-0.50 07H 07C 27 26 PCT 1.39 0

21 P2 AV3 0.00 TEH TEC 27 26 WAR 0.25 120 2

AV3 0.00 07H 07C 27 26 PCT 1.27 0

20 P2 AV4

-0.17 TEH TEC 27 26 WAR 0.35 318 2

AV4 0.00 07H 07C 27 27 DSI 0.84 52 P1 011H 0.11 TEH TEC 27 28 DSI 0.67 47 P1 02H

-0.06 TEH TEC 27 28 SAI 0.24 71 6

02H

-0.09 0.15 02H 02H 27 33 DSI 0.36 50 P1 01H 0.03 TEH TEC 27 39 DSI 0.57 55 P1 01H 0.17 TEH TEC 27 39 MAI 0.33 113 6

011H 0.06 0.40 01H 01H 27 39 DSI 0.52 90 P1 02H 0.00 TEH TEC 27 42 DSI 0.77 39 P1 01H 0.03 TEH TEC 27 42 SAI 0.39 93 6

01H

-0.01 0.25 01H 01H 27 44 DSI 0.76 62 P1 01H 0.06 TEH TEC 27 44 SAI 0.46 111 6

01H 0.00 0.44 01H 01H 27 44 DSI 0.38 45 P1 02H 0.00 TEH TEC 27 45 DSI 0.97 94 P1 01H 0.03 TEH TEC 27 45 DSI 1.19 96 P1 02H

-0.11 TEH TEC 27 47 DSI 1.75 99 P1 01H 0.11 TEH TEC 27 50 DSI 0.28 81 P1 01H

-0.05 TEH TEC

Beaver Valley Unit #1 1 R15 S/G Examination Results 1RC-E-1C (TUBES WITH INDICATIONS)

Page 16 of 28 A

Row Col 27 50 27 50 27 60 27 62 27 62 27 63 27 63 27 73 27 75 27 81 27 81 27 81 27 84 28 10 28 10 28 14 28 16 28 16 28 16 28 21 28 21 28 21 28 21 28 23 28 24 28 25 28 28 28 28 28 31 28 31 28 31 28 34 28 36 28 36 28 36 28 36 28 36 28 36 28 37 28 41 28 41 28 41 28 41 28 41 28 41 28 49 28 49 28 50 28 50 28 52 28 54 Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To DSI 0.77 62 P1 02H 0.08 TEH TEC SAI 0.26 96 6

02H

-0.03 0.40 02H 02H SAI 0.58 14 6

TSH

-0.50 0.24 TSH TSH DSI 0.51 66 P1 02H 0.06 TEH TEC SAI 0.28 93 6

02H 0.00 0.46 02H 02H DSI 0.24 117 P1 01H 0.08 TEH TEC DSI 0.71 110 P1 02H 0.00 TEH TEC DSI 0.79 152 P1 01H 0.11 TEH TEC DSI 0.62 48 P1 02H 0.08 TEH TEC DSI 0.31 60 P1 01H 0.11 TEH TEC DSI 0.85 44 P1 02H 0.11 TEH TEC DSI 0.59 74 P1 05H 0.19 TEH TEC PCT 0.35 132 17 P1 01C 0.00 TEH TEC DSI 0.81 121 P1 01H

-0.08 TEH TEC DSI 0.54 73 P1 02H 0.11 TEH TEC DSI 0.52 62 P1 01H 0.05 TEH TEC DSI 0.67 40 P1 01H 0.00 TEH TEC SAI 0.52 98 6

01H

-0.08 0.41 01H 01H DSI 0.42 55 P1 03H 0.00 TEH TEC SPR 1.53 114 P1 01H 0.00 TEH TEC DSI 1.24 85 P1 01H 0.00 TEH TEC MAI 0.89 97 6

01H

-0.06 0.49 01H 01H DSI 1.35 99 P1 02H

-0.03 TEH TEC DSI 1.26 101 P1 01H 0.06 TEH TEC DSI 0.69 69 P1 01H 0.00 TEH TEC DSI 1.18 126 P1 01H 0.00 TEH TEC DSI 1.34 114 P1 01H 0.08 TEH TEC DSI 0.28 38 P1 02H 0.11 TEH TEC DSI 1.81 96 P1 01H 0.08 TEH TEC SAI 1.49 85 6

O1H 0.08 0.49 01H 01H DSI 0.97 102 P1 02H

-0.11 TEH TEC DSI 1.37 100 P1 01H 0.14 TEH TEC DSI 1.54 113 P1 01H 0.28 TEH TEC DSI 0.99 117 P1 02H

-0.03 TEH TEC DSI 1.10 125 P1 03H

-0.20 TEH TEC SAI 0.30 114 6

03H

-0.17 0.40 03H 03H SAI 0.35 117 6

03H

-0.17 0.40 03H 03H NOI 0.89 118 3

06C 43.15 TEH TEC DSI 0.18 79 P1 02H 0.14 TEH TEC DSI 1.43 108 P1 01H 0.19 TEH TEC SAI 1.00 94 6

01H

-0.01 0.63 TSH 01H DSI 0.52 51 P1 02H 0.08 TEH TEC SAI 0.40 106 6

02H

-0.01 0.25 02H 02H NQI 0.65 115 3

04C 47.17 TEH TEC NOI 0.78 116 3

TSH 17.72 TEH TEC DSI 0.33 51 P1 01H 0.08 TEH TEC DSI 1.96 66 P1 02H 0.06 TEH TEC DSI 0.63 90 P1 01H 0.03 TEH TEC SAI 0.80 102 6

01H 0.00 0.35 01H 01H DSI 0.63 102 P1 02H 0.11 TEH TEC DSI 0.14 117 P1 01H 0.05 TEH TEC

Beaver Valley Unit #1 Page 17 of 28 1 R1 5 S/G Examination Results 1RC-E-1C (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inchl Cr-Length Cr-Angle From To 28 55 DSI 0.77 32 P1 02H 0.08 TEH TEC 28 55 SAI 0.27 139 6

02H 0.08 0.18 02H 02H 28 58 DSI 0.46 87 P1 011H 0.05 TEH TEC 28 58 DSI 0.46 36 P1 02H 0.05 TEH TEC 28 59 DSI 0.56 38 P1 02H 0.03 TEH TEC 28 60 DSI 0.47 68 P1 01H 0.11 TEH TEC 28 60 DSI 0.77 106 P1 02H

-0.17 TEH TEC 28 62 DSI 0.67 39 P1 02H 0.08 TEH TEC 28 62 SAI 0.57 99 6

02H

-0.03 0.68 02H 02H 28 62 DSI 1.15 81 P1 03H 0.06 TEH TEC 28 68 DSI 0.34 24 P1 02H 0.08 TEH TEC 28 70 SAI 0.60 13 6

TSH

-2.16 0.19 TSH TSH 29 15 PCT 0.84 138 0

P1 01C

-0.14 TEH TEC 29 15 DSI 0.35 110 P1 01H 0.06 TEH TEC 29 22 DSI 1.45 94 P1 01H 0.00 TEH TEC 29 22 DSI 1.40 90 P1 02H 0.03 TEH TEC 29 27 DSI 1.97 57 P1 01H 0.08 TEH TEC 29 27 DSI 1.21 26 P1 02H 0.08 TEH TEC 29 27 MAI 0.43 95 6

02H

-0.10 0.54 02H 02H 29 28 DSI 1.51 90 P1 01H 0.11 TEH TEC 29 28 DSI 0.82 81 P1 02H 0.06 TEH TEC 29 29 DSI 1.07 72 P1 01H 0.03 TEH TEC 29 29 DSI 0.26 66 P1 02H 0.06 TEH TEC 29 32 DSI 0.75 31 P1 01H 0.11 TEH TEC 29 32 SAI 0.58 92 6

01H 0.11 0.52 01H 01H 29 32 DSI 0.61 85 P1 02H

-0.11 TEH TEC 29 32 DSI 0.30 60 P1 03H 0.08 TEH TEC 29 33 DSI 0.86 43 P1 01H 0.08 TEH TEC 29 33 SAI 0.44 95 6

01H 0.03 0.30 01H 01H 29 33 DSI 0.63 54 P1 02H 0.00 TEH TEC 29 35 DSI 0.72 37 P1 011H 0.08 TEH TEC 29 35 MAI 0.24 107 6

O1H 0.02 0.40 01H 01H 29 35 DSI 0.47 42 P1 02H 0.06 TEH TEC 29 36 DSI 0.70 113 P1 01H 0.11 TEH TEC 29 38 DSI 0.41 66 P1 01H 0.05 TEH TEC 29 40 DSI 0.92 68 P1 01H 0.08 TEH TEC 29 41 DSI 0.63 35 P1 02H 0.00 TEH TEC 29 41 MAI 0.26 101 6

02H 0.04 0.33 02H 02H 29 42 DSI 0.70 123 P1 02H 0.25 TEH TEC 29 42 DSI 0.50 83 P1 04H 0.03 TEH TEC 29 45 DSI 0.63 124 P1 01H 0.19 TEH TEC 29 45 DSI 0.62 81 P1 02H 0.00 TEH TEC 29 46 PCT 3.19 0

32 P2 AV1 0.00 TEH TEC 29 46 WAR 0.53 134 2

AV1 0.00 07C 07H 29 46 PCT 5.94 0

39 P2 AV2 0.63 TEH TEC 29 46 PCT 2.01 0

27 P2 AV2

-0.58 TEH TEC 29 46 WAR 0.34 142 2

AV2

-0.57 07C 07H 29 46 WAR 0.65 112 2

AV2 0.74 07C 07H 29 46 PCT 2.06 0

27 P2 AV3

-0.30 TEH TEC 29 46 PCT 5.06 0

37 P2 AV3 0.39 TEH TEC 29 46 WAR 0.76 111 2

AV3 0.29 07C 07H

Beaver Valley Unit #1 Page 18 of 28 1 R15 S/G Examination Results 1 RC-E-1 C (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 29 46 WAR 0.36 137 2

AV3

-0.40 07C 07H 29 46 PCT 2.87 0

31 P2 AV4 0.00 TEH TEC 29 46 WAR 0.53 137 2

AV4 0.00 07C 07H 29 48 DSI 0.64 75 P1 02H

-0.03 TEH TEC 29 49 DSI 1.10 108 P1 01H 0.17 TEH TEC 29 49 DSI 1.31 106 P1 02H

-0.06 TEH TEC 29 51 DSI 0.72 35 P1 02H 0.00 TEH TEC 29 51 SAI 0.28 103 6

02H 0.00 0.22 02H 02H 29 52 DSI 0.62 44 P1 02H 0.00 TEH TEC 29 53 DSI 0.53 107 P1 01H 0.06 TEH TEC 29 54 DSI 0.56 37 P1 01H 0.00 TEH TEC 29 56 DSI 0.59 129 P1 02H

-0.08 TEH TEC 29 57 DSI 0.52 59 P1 01H 0.11 TEH TEC 29 57 DSI 0.52 66 P1 02H 0.08 TEH TEC 29 61 DSI 0.33 75 P1 02H 0.11 TEH TEC 29 64 DSI 0.89 77 P1 01H 0.14 TEH TEC 29 67 DSI 0.43 78 P1 02H 0.00 TEH TEC 29 73 DSI 0.35 112 P1 01H 0.05 TEH TEC 29 83 DSI 0.48 135 P1 01H 0.17 TEH TEC 29 84 PCT 1.45 132 14 P1 01C

-0.11 TEH TEC 30 20 DSI 0.26 63 P1 02H 0.00 TEH TEC 30 21 DSI 0.17 100 P1 02H 0.03 TEH TEC 30 21 SVI 0.17 107 6

TSH 0.28 0.57 64 TSH TSH 30 23 DSI 0.43 72 P1 01H

-0.03 TEH TEC 30 23 DSI 0.74 75 P1 02H

-0.03 TEH TEC 30 24 DSI 0.24 98 P1 01H

-0.03 TEH TEC 30 24 DSI 0.65 82 P1 02H 0.03 TEH TEC 30 27 DSI 0.30 65 P1 01H 0.08 TEH TEC 30 27 DSI 0.81 60 P1 02H 0.03 TEH TEC 30 27 SAI 0.48 98 6

02H

-0.07 0.34 02H 02H 30 33 DSI 0.80 66 P1 01H 0.14 TEH TEC 30 33 SAI 0.27 86 6

01H 0.12 0.15 01H 01H 30 33 SAI 0.21 102 6

01H

-0.07 0.25 01H 01H 30 33 DSI 0.22 40 P1 02H 0.08 TEH TEC 30 33 SAI 0.75 12 6

TSH

-3.14 0.14 TSH TSH 30 36 DSI 1.02 122 P1 01H

-0.03 TEH TEC 30 36 DSI 0.76 112 P1 02H

-0.11 TEH TEC 30 38 DSI 1.34 99 P1 01H 0.08 TEH TEC 30 40 NOI 0.66 119 3

TSC 28.06 TEH TEC 30 43 DSI 0.58 47 P1 01H 0.05 TEH TEC 30 43 DSI 0.28 84 P1 03H 0.08 TEH TEC 30 44 DSI 1.64 79 P1 01H 0.22 TEH TEC 30 49 DSI 0.37 86 P1 01H 0.06 TEH TEC 30 49 SAI 0.39 88 6

01H

-0.02 0.35 01H 01H 30 49 DSI 0.44 54 P1 02H 0.03 TEH TEC 30 53 DSI 0.76 65 P1 01H 0.06 TEH TEC 30 53 SAI 0.76 102 6

O1H 0.06 0.49 01H 01H 30 55 DSI 0.45 69 P1 04H 0.00 TEH TEC 30 56 DSI 0.66 89 P1 02H 0.00 TEH TEC 30 56 SAI 0.47 94 6

02H

-0.06 0.33 02H 02H 30 57 DSI 0.52 58 P1 02H 0.08 TEH TEC

Beaver Valley Unit #1 Page 19 of 28 1 R1 5 S/G Examination Results 1RC-E-1C (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 30 61 DSI 0.44 70 P1 02H 0.08 TEH TEC 30 62 DSI 0.71 46 P1 01H 0.06 TEH TEC 30 62 SAI 0.57 85 6

01H 0.02 0.66 01H 01H 30 63 DSI 1.94 101 P1 01H 0.22 TEH TEC 30 63 DSI 0.73 107 P1 02H 0.11 TEH TEC 30 65 DSI 0.65 25 P1 02H 0.08 TEH TEC 30 65 SAI 0.31 107 6

02H 0.00 0.32 02H 02H 30 66 DSI 0.53 42 P1 02H 0.03 TEH TEC 30 68 DSI 1.42 95 P1 01H 0.17 TEH TEC 30 70 DSI 0.93 87 P1 01H 0.03 TEH TEC 30 70 SAI 0.71 104 6

01H 0.13 0.46 01H 01H 30 79 PCT 0.50 151 0

P1 01C -0.17 TEH TEC 30 79 VOL 0.16 139 3

01C -0.13 01C 01C 30 83 PCT 0.58 147 0

P1 01C -0.11 TEH TEC 31 19 DSI 1.64 98 P1 01H 0.14 TEH TEC 31 19 DSI 0.97 58 P1 04H

-0.03 TEH TEC 31 19 DSI 0.32 86 P1 06H 0.00 TEH TEC 31 22 DSI 0.56 127 P1 01H 0.08 TEH TEC 31 26 DSI 0.94 106 P1 01H 0.03 TEH TEC 31 26 DSI 1.17 52 P1 02H 0.00 TEH TEC 31 27 DSI 1.39 133 P1 01H

-0.08 TEH TEC 31 27 MAI 1.00 93 6

01H

-0.04 0.49 01H 01H 31 27 DSI 0.27 64 P1 03H 0.06 TEH TEC 31 28 DSI 0.58 76 P1 01H 0.00 TEH TEC 31 30 DSI 1.62 99 P1 01H 0.08 TEH TEC 31 32 DSI 0.61 49 P1 01H 0.06 TEH TEC 31 32 DSI 0.51 50 P1 02H 0.03 TEH TEC 31 32 DSI 0.59 83 P1 03H

-0.03 TEH TEC 31 34 DSI 0.37 111 P1 02H 0.14 TEH TEC 31 34 DSI 0.64 91 P1 03H

-0.06 TEH TEC 31 35 DSI 1.77 100 P1 01H 0.25 TEH TEC 31 35 DSI 0.86 116 P1 02H

-0.22 TEH TEC 31 35 DSI 0.51 127 P1 04H 0.00 TEH TEC 31 38 DSI 0.64 111 P1 01H 0.05 TEH TEC 31 38 MAI 0.37 92 6

01H 0.08 0.37 01H 01H 31 39 DSI 1.72 87 P1 01H 0.14 TEH TEC 31 39 MAI 0.85 84 6

01H

-0.01 0.60 01H 01H 31 40 DSI 0.28 52 P1 01H 0.00 TEH TEC 31 43 DSI 1.21 102 P1 01H 0.14 TEH TEC 31 45 DSI 0.61 49 P1 01H 0.06 TEH TEC 31 46 DSI 0.75 55 P1 01H 0.06 TEH TEC 31 47 DSI 0.59 57 P1 02H 0.00 TEH TEC 31 48 DSI 1.62 99 P1 02H 0.00 TEH TEC 31 50 DSI 1.28 97 P1 02H

-0.06 TEH TEC 31 50 MAI 0.29 95 6

02H

-0.05 0.48 02H 02H 31 57 SAI 0.53 16 6

TSH

-3.63 0.21 TSH TSH 31 59 DSI 1.20 94 P1 01H 0.08 TEH TEC 31 61 DSI 0.46 46 P1 01H 0.08 TEH TEC 31 62 DSI 0.34 126 P1 01H 0.11 TEH TEC 31 62 DSI 0.66 37 P1 03H 0.03 TEH TEC 31 62 SAI 0.32 108 6

03H 0.03 0.40 03H 03H

Beaver Valley Unit #1 Page 20 of 28 1 R1 5 S/G Examination Results 1RC-E-1C (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 31 63 DSI 0.49 24 P1 03H 0.00 TEH TEC 31 67 DSI 0.63 53 P1 03H

-0.06 TEH TEC 31 67 SAI 0.53 102 6

03H

-0.12 0.27 03H 03H 31 69 DSI 0.25 68 P1 02H 0.11 TEH TEC 32 22 DSI 0.34 73 P1 01H 0.03 TEH TEC 32 27 DSI 1.31 96 P1 01H

-0.06 TEH TEC 32 28 DSI 1.74 98 P1 01H 0.06 TEH TEC 32 28 MAI 1.58 88 6

01H 0.08 0.59 01H 01H 32 28 DSI 0.68 99 P1 02H 0.11 TEH TEC 32 30 DSI 0.22 43 P1 01H 0.06 TEH TEC 32 30 DSI 0.79 51 P1 03H 0.00 TEH TEC 32 32 DSI 0.79 73 P1 02H 0.11 TEH TEC 32 33 DSI 0.82 52 P1 01H 0.00 TEH TEC 32 34 DSI 0.66 89 P1 02H 0.00 TEH TEC 32 35 DS1 0.91 87 P1 01H

-0.03 TEH TEC 32 36 DSI 1.59 87 P1 01H 0.08 TEH TEC 32 36 MAI 0.91 89 6

01H 0.06 0.64 01H 01H 32 36 DSI 1.10 75 P1 02H 0.00 TEH TEC 32 36 MAI 0.50 93 6

02H

-0.04 0.32 02H 02H 32 37 DSI 0.96 67 P1 01H 0.22 TEH TEC 32 39 DSI 1.12 72 P1 02H

-0.06 TEH TEC 32 39 DSI 0.83 91 P1 03H

-0.14 TEH TEC 32 42 DSI 0.86 130 P1 01H 0.19 TEH TEC 32 43 DSI 1.41 87 P1 O1H 0.17 TEH TEC 32 43 DSI 1.18 87 P1 02H 0.06 TEH TEC 32 46 DSI 1.50 87 P1 01H 0.06 TEH TEC 32 52 DSI 0.67 67 P1 02H 0.06 TEH TEC 32 53 DSI 0.12 78 P1 01H 0.00 TEH TEC 32 53 SAI 0.22 83 6

01H 0.00 0.27 01H 01H 32 53 DSI 0.92 119 P1 02H

-0.19 TEH TEC 32 57 DSI 1.33 106 P1 01H 0.17 TEH TEC 32 57 SAI 0.70 97 6

01H 0.20 0.38 01H 01H 32 57 DSI 0.82 102 P1 02H

-0.06 TEH TEC 32 58 DSI 0.36 38 P1 02H 0.16 TEH TEC 32 58 DSI 0.35 32 P1 03H 0.00 TEH TEC 32 60 DSI 0.43 86 P1 01H 0.28 TEH TEC 32 64 DSI 0.13 69 P1 01H 0.03 TEH TEC 32 64 SAI 0.21 110 6

01H 0.00 0.41 01H 01H 32 69 DSI 0.33 45 P1 01H 0.06 TEH TEC 32 69 DSI 0.35 93 P1 02H 0.06 TEH TEC 32 70 DSI 0.50 130 P1 02H 0.25 TEH TEC 33 18 PCT 1.99 116 31 P1 01C -0.20 TEH TEC 33 18 VOL 0.63 118 3

01C -0.16 01C 01C 33 21 DSI 0.24 54 P1 04H 0.00 TEH TEC 33 23 DSI 0.57 121 P1 01H 0.03 TEH TEC 33 25 DSI 0.40 112 P1 01H 0.06 TEH TEC 33 25 DSI 1.00 80 P1 02H 0.06 TEH TEC 33 26 DSI 1.76 83 P1 01H 0.14 TEH TEC 33 26 DSI 0.56 66 P1 02H 0.03 TEH TEC 33 27 DSI 0.75 110 P1 01H

-0.11 TEH TEC 33 27 SAI 0.73 92 6

01H

-0.03 0.32 01H 01H

Beaver Valley Unit #1 Page 21 of 28 1 R1 5 S/G Examination Results 1 RC-E-1 C (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 33 30 DSI 1.53 107 P1 01H 0.00 TEH TEC 33 31 DSI 0.97 115 P1 01H

-0.11 TEH TEC 33 36 DSI 0.27 54 P1 011H 0.06 TEH TEC 33 36 DSI 0.52 68 P1 02H

-0.06 TEH TEC 33 45 DSI 0.46 67 P1 02H 0.11 TEH TEC 33 49 DSI 0.55 96 P1 01H 0.03 TEH TEC 33 50 DSI 0.55 53 P1 02H 0.05 TEH TEC 33 50 SAI 0.31 107 6

02H 0.05 0.42 02H 02H 33 51 DSI 0.91 124 P1 01H 0.06 TEH TEC 33 51 DSI 0.40 69 P1 02H 0.14 TEH TEC 33 53 DSI 0.67 120 P1 02H

-0.03 TEH TEC 33 59 DSI 0.31 74 P1 03H 0.06 TEH TEC 33 63 DSI 0.48 60 P1 01H 0.03 TEH TEC 33 63 SAI 0.28 70 6

01H 0.03 0.24 01H 01H 33 63 DSI 0.54 63 P1 02H 0.06 TEH TEC 33 63 SAI 0.37 106 6

02H

-0.01 0.39 02H 02H 33 68 DSI 1.40 104 P1 01H 0.24 TEH TEC 33 68 MAI 1.26 85 6

01 H 0.00 0.53 01H 01H 33 68 DSI 0.56 52 P1 02H 0.00 TEH TEC 33 78 PCT 0.30 137 0

P1 01C

-0.03 TEH TEC 33 78 DSI 0.74 134 P1 04H 0.30 TEH TEC 34 21 DSI 0.50 109 P1 011H 0.03 TEH TEC 34 21 DSI 0.39 123 P1 05H 0.17 TEH TEC 34 26 DSI 0.87 62 P1 02H 0.11 TEH TEC 34 28 DSI 1.14 83 P1 01H 0.03 TEH TEC 34 28 DSI 0.50 65 P1 03H 0.03 TEH TEC 34 29 DSI 1.18 108 P1 01H 0.14 TEH TEC 34 29 DSI 0.60 61 P1 02H 0.03 TEH TEC 34 29 SAI 0.60 91 6

02H

-0.10 0.54 02H 02H 34 30 DSI 0.90 38 P1 01H 0.11 TEH TEC 34 30 MAI 0.87 90 6

01H

-0.02 0.44 01H 011H 34 31 DSI 1.85 106 P1 01H 0.06 TEH TEC 34 32 DSI 1.25 105 P1 01H

-0.03 TEH TEC 34 32 DSI 0.79 100 P1 02H

-0.11 TEH TEC 34 32 DSI 0.75 112 P1 03H

-0.08 TEH TEC 34 32 SAI 0.34 95 6

03H 0.03 0.56 03H 03H 34 33 DNI 1.24 35 5

TSC 36.65 TEH TEC 34 36 DSI 0.51 45 P1 01H 0.03 TEH TEC 34 39 DSI 0.48 51 P1 02H

-0.03 TEH TEC 34 40 DSI 0.75 59 P1 011H 0.08 TEH TEC 34 40 DSI 0.51 47 P1 03H 0.14 TEH TEC 34 40 DSI 0.30 88 P1 05H 0.06 TEH TEC 34 43 DSI 0.48 102 P1 01H 0.08 TEH TEC 34 47 WAR 0.27 117 2

AV1 0.00 07H 07C 34 47 PCT 1.04 0

16 P2 AV2

-0.44 TEH TEC 34 47 WAR 0.31 107 2

AV2

-0.44 07H 07C 34 50 DSI 0.60 63 P1 02H 0.08 TEH TEC 34 54 DSI 0.56 64 P1 02H 0.00 TEH TEC 34 55 PCT 0.57 0

12 P2 AV2

-0.14 TEH TEC 34 55 WAR 0.27 148 2

AV2

-0.14 07H 07C 34 56 DSI 0.66 85 P1 01H 0.05 TEH TEC

Beaver Valley Unit #1 Page 22 of 28 1 R1 5 S/G Examination Results 1 RC-E-1 C (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 34 56 DSI 0.32 115 P1 02H 0.16 TEH TEC 34 59 DSI 0.32 66 P1 011H 0.03 TEH TEC 34 63 DSI 0.64 75 P1 01H 0.06 TEH TEC 34 66 PCT 0.49 0

11 P2 AV3 0.00 TEH TEC 34 66 WAR 0.29 142 2

AV3 0.00 07H 07C 34 66 PCT 1.01 0

18 P2 AV4 0.00 TEH TEC 34 66 WAR 0.32 322 2

AV4 0.00 07H 07C 34 77 PCT 1.21 120 25 P1 01C

-0.17 TEH TEC 34 77 PCT 0.64 155 0

P1 02C

-0.11 TEH TEC 34 79 PCT 0.78 128 11 P1 01C

-0.06 TEH TEC 34 79 PCT 1.96 122 20 P1 02C

-0.06 TEH TEC 35 20 DSI 0.72 113 P1 01H 0.17 TEH TEC 35 20 MAI 0.20 95 6

01H 0.15 0.29 01H 01H 35 20 DSI 0.58 95 P1 02H 0.00 TEH TEC 35 20 MAI 0.27 109 6

02H 0.00 0.32 02H 02H 35 26 DSI 0.54 59 P1 011H 0.00 TEH TEC 35 26 MAI 0.32 92 6

01H

-0.02 0.27 01H 01H 35 27 DSI 0.64 109 P1 01H

-0.03 TEH TEC 35 27 SAI 0.47 97 6

01H

-0.03 0.29 011H 01H 35 28 DSI 1.01 55 P1 011H 0.06 TEH TEC 35 28 DSI 1.31 83 P1 02H 0.03 TEH TEC 35 28 MAI 0.70 99 6

02H

-0.05 0.51 02H 02H 35 28 DSI 0.45 98 P1 04H 0.06 TEH TEC 35 30 DSI 0.81 40 P1 01H 0.06 TEH TEC 35 30 MAI 0.47 94 6

01H

-0.02 0.56 01H 01H 35 30 NQI 0.49 94 3

02H 25.35 TEH TEC 35 30 DSI 0.38 44 P1 02H 0.06 TEH TEC 35 30 SAI 0.37 102 6

02H

-0.02 0.46 02H 04H 35 30 NOI 1.15, 120 3

03C 7.89 TEH TEC 35 30 NQI 2.15 84 6

03H 42.78 TEH TEC 35 30 NOI 2.38 90 6

03H 34.27 TEH TEC 35 30 NOI 2.29 87 6

06C 3.26 TEH TEC 35 31 DSI 1.87 108 P1 01H 0.06 TEH TEC 35 31 DSI 0.63 133 P1 02H

-0.03 TEH TEC 35 33 DSI 0.60 55 P1 01H 0.03 TEH TEC 35 34 DSI 0.89 105 P1 01H

-0.08 TEH TEC 35 34 DSI 0.54 37 P1 02H 0.00 TEH TEC 35 35 DSI 0.65 56 P1 02H 0.00 TEH TEC 35 40 DSI 0.46 53 P1 01H 0.05 TEH TEC 35 40 DSI 0.60 103 P1 03H 0.17 TEH TEC 35 43 DSI 0.81 124 P1 01H 0.03 TEH TEC 35 43 DSI 0.57 102 P1 02H 0.00 TEH TEC 35 45 NOI 1.57 124 3

01H 38.54 TEH TEC 35 45 DSI 0.96 102 P1 011H 0.08 TEH TEC 35 45 SAI 0.87 87 6

01H 0.01 0.52 01H 02H 35 45 DSI 0.28 132 P1 02H 0.14 TEH TEC 35 45 MAI 0.55 99 6

02H 0.05 0.71 01 H 02H 35 47 DSI 1.28 127 P1 01H 0.11 TEH TEC 35 47 DSI 1.45 121 P1 04H

-0.19 TEH TEC 35 49 DSI 0.36 17 P1 01H

-0.03 TEH TEC 35 49 SAI 0.43 73 6

01H 0.08 0.38 01H 01H

Beaver Valley Unit #1 Page 23 of 28 1 R1 5 S/G Examination Results 1 RC-E-1 C (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 35 53 DSI 1.26 80 P1 01H 0.06 TEH TEC 35 55 DSI 0.91 94 P1 01H 0.11 TEH TEC 35 55 DSI 0.70 67 P1 02H 0.00 TEH TEC 35 55 MAI 0.25 95 6

02H

-0.06 0.28 02H 02H 35 55 DSI 0.41 65 P1 03H 0.00 TEH TEC 35 55 DSI 0.43 35 P1 05H 0.08 TEH TEC 35 61 DSI 0.76 54 P1 02H 0.08 TEH TEC 35 63 DSI 0.86 112 P1 01H 0.03 TEH TEC 35 63 DSI 0.42 27 P1 02H 0.00 TEH TEC 35 63 DSI 0.60 46 P1 03H 0.03 TEH TEC 35 66 SAI 0.74 14 6

TSH

-7.72 0.29 TSH TSH 35 67 DSI 1.28 103 P1 01H 0.06 TEH TEC 35 67 SAI 0.56 93 6

01H

-0.02 0.39 01H 01H 35 67 DSI 0.67 102 P1 02H

-0.11 TEH TEC 35 67 MAI 0.48 106 6

02H

-0.06 0.42 02H 02H 35 78 PCT 1.14 122 27 P1 04C

-0.22 TEH TEC 36 21 DSI 0.55 76 P1 05H 0.11 TEH TEC 36 22 NOI 0.77 125 3

01C 41.97 TEH TEC 36 22 NOI 2.11 84 6

02C 41.77 TEH TEC 36 22 DSI 1.01 85 P1 02H 0.00 TEH TEC 36 22 NQI 1.00 120 3

05C 25.15 TEH TEC 36 23 DSI 0.63 70 P1 01H 0.03 TEH TEC 36 28 NOI 0.64 120 3

01C 17.10 TEH TEC 36 28 DSI 0.85 94 P1 01H 0.03 TEH TEC 36 28 NQI 0.82 111 3

02H 12.81 TEH TEC 36 28 NOI 0.95 107 3

02H 40.35 TEH TEC 36 28 DSI 0.25 105 P1 02H 0.06 TEH TEC 36 28 SAI 0.27 113 6

02H

-0.03 0.46 02H 03H 36 28 NOI 5.36 86 6

03C 11.66 TEH TEC 36 29 DSI 0.41 47 P1 01H 0.00 TEH TEC 36 31 DSI 0.81 92 P1 01H 0.14 TEH TEC 36 31 MAI 0.36 100 6

01H 0.08 0.34 01H 01H 36 35 DSI 1.53 97 P1 01H 0.22 TEH TEC 36 35 DSI 0.77 69 P1 02H 0.06 TEH TEC 36 36 NOI 0.98 110 3

01C 23.88 TEH TEC 36 36 DSI 1.71 97 P1 02H

-0.08 TEH TEC 36 36 DSI 0.53 66 P1 03H 0.08 TEH TEC 36 36 NOI 2.61 88 6

TSC 33.88 TEH TEC 36 37 DSI 0.59 162 P1 01H 0.03 TEH TEC 36 41 DSI 1.01 100 P1 01H 0.11 TEH TEC 36 41 DSI 0.91 83 P1 02H 0.06 TEH TEC 36 41 MAI 0.38 116 6

02H

-0.06 0.47 02H 02H 36 41 DSI 0.67 94 P1 03H 0.11 TEH TEC 36 42 DSI 0.95 126 P1 01H

-0.16 TEH TEC 36 42 SAI 0.33 119 6

01H

-0.05 0.55 01H 01H 36 43 DSI 1.11 119 P1 011H

-0.11 TEH TEC 36 43 DSI 0.55 39 P1 02H 0.06 TEH TEC 36 44 DSI 0.30 80 P1 011H 0.03 TEH TEC 36 45 DSI 0.94 118 P1 01H 0.30 TEH TEC 36 45 SAI 0.60 101 6

01H 0.02 0.58 01H 01H 36 45 DSI 1.48 104 P1 02H

-0.08 TEH TEC

Beaver Valley Unit #1 Page 24 of 28 1 R1 5 S/G Examination Results 1RC-E-1C (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 36 45 NOI 0.87 89 3

03C 27.20 TEH TEC 36 47 PCT 0.95 0

15 P2 AV1 0.03 TEH TEC 36 47 WAR 0.36 119 2

AV1 0.00 07H 07C 36 47 POT 2.14

- 0 28 P2 AV2

-0.42 TEH TEC 36 47 WAR 0.53 123 2

AV2

-0.49 07H 07C 36 47 WAR 0.20 146 2

AV4

-0.10 07H 07C 36 50 DSI 0.52 133 P1 01H 0.16 TEH TEC 36 50 SAI 0.42 97 6

01 H 0.04 0.46 01 H 01 H 36 50 DSI 0.87 72 P1 03H 0.03 TEH TEC 36 50 SAI 0.67 88 6

03H 0.03 0.44 03H 03H 36 52 DSI 0.41 82 P1 03H 0.06 TEH TEC 36 54 DSI 0.65 77 P1 03H 0.17 TEH TEC 36 64 PCT 0.59 0

12 P2 AV3 0.00 TEH TEC 36 64 WAR 0.25 111 2

AV3

-0.20 07H 07C 36 64 POT 1.66 34 23 P2 AV4 0.32 TEH TEC 36 64 WAR 0.30 139 2

AV4 0.32 07H 07C 36 69 POT 0.98 0

17 P2 AV1 0.61 TEH TEC 36 69 WAR 0.30 132 2

AV1 0.54 07H 07C 36 69 PCT 0.90 0

16 P2 AV2

-0.33 TEH TEC 36 69 WAR 0.34 104 2

AV2

-0.33 07H 07C 36 69 WAR 0.28 123 2

AV2 0.49 07H 07C 36 69 POT 0.81 0

15 P2 AV3

-0.28 TEH TEC 36 69 WAR 0.30 126 2

AV3 0.32 07H 07C 36 76 POT 1.82 143 0

P1 01C

-0.14 TEH TEC 36 76 VOL 0.53 121 3

01C

-0.04 01C 01C 36 77 POT 0.46 117 28 P1 04C 0.03 TEH TEC 37 19 PCT 0.69 124 23 P1 01C

-0.19 TEH TEC 37 20 DSI 0.86 113 P1 011H 0.19 TEH TEC 37 20 SAI 0.25 94 6

01H 0.13 0.22 01H 01H 37 25 DSI 0.53 96 P1 01H 0.00 TEH TEC 37 26 DSI 1.09 101 P1 01H

-0.06 TEH TEC 37 28 DSI 0.75 68 P1 01H 0.06 TEH TEC 37 28 SAI 1.05 85 6

01H 0.03 0.39 01H 01H 37 29 DSI 0.58 97 P1 01H 0.03 TEH TEC 37 29 MAI 0.75 89 6

01H

-0.02 0.51 01H 01H 37 33 DSI 0.79 28 P1 02H 0.00 TEH TEC 37 33 SAI 0.45 101 6

02H 0.05 0.38 02H 02H 37 36 DSI 0.82 55 P1 02H 0.06 TEH TEC 37 37 DSI 0.50 82 P1 01H 0.03 TEH TEC 37 38 DSI 0.67 41 P1 02H 0.08 TEH TEC 37 38 SAI 0.32 98 6

02H

-0.09 0.36 02H 02H 37 38 DSI 0.40 26 P1 03H 0.06 TEH TEC 37 38 SAI 0.13 88 6

03H

-0.07 0.28 03H 03H 37 41 DSI 1.35 104 P1 01H 0.14 TEH TEC 37 41 DSI 0.79 83 P1 02H 0.06 TEH TEC 37 41 DSI 0.87 102 P1 03H

-0.19 TEH TEC 37 42 DSI 1.39 85 P1 011H 0.19 TEH TEC 37 45 DSI 0.66 98 P1 01H 0.11 TEH TEC 37 45 SAI 0.74 88 6

01H 0.02 0.41 01H 01H 37 45 NQI 1.17 119 3

02C 14.45 TEH TEC 37 50 DSI 0.31 14 P1 01H 0.06 TEH TEC

Beaver Valley Unit #1 Page 25 of 28 1 R1 5 S/G Examination Results 1RC-E-1C (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 37 50 MAI 0.17 99 6

01H 0.04 0.39 01H 01H 37 52 DSI 0.48 88 P1 01H 0.06 TEH TEC 37 59 DSI 0.86 29 P1 02H 0.08 TEH TEC 37 59 SAI 0.44 101 6

02H 0.08 0.42 02H 02H 37 62 DSI 0.69 137 P1 01H 0.11 TEH TEC 37 62 DSI 1.54 95 P1 02H

-0.03 TEH TEC 37 65 DSI 0.89 118 P1 01H 0.19 TEH TEC 37 74 PCT 0.98 131 5

P1 01C 0.00 TEH TEC 37 74 VOL 0.16 118 3

01C

-0.01 01C 01C 37 76 PCT 0.42 128 10 P1 01C

-0.33 TEH TEC 37 76 VOL 0.07 135 3

01C

-0.07 01C 01C 38 23 PCT 1.30 113 34 P1 01C

-0.25 TEH TEC 38 23 DSI 0.33 101 P1 01H 0.03 TEH TEC 38 23 DSI 0.55 84 P1 03H 0.06 TEH TEC 38 27 DSI 0.91 42 P1 02H 0.03 TEH TEC 38 27 SAI 0.40 88 6

02H

-0.06 0.25 02H 02H 38 27 DSI 0.33 133 P1 06H

-0.06 TEH TEC 38 30 DSI 0.52 92 P1 01H 0.06 TEH TEC 38 31 DSI 0.63 111 P1 01H 0.08 TEH TEC 38 31 MAI 0.27 88 6

01H 0.00 0.29 01H 01H 38 32 DSI 1.46 82 P1 01H 0.06 TEH TEC 38 32 SAI 1.69 84 6

01H

-0.01 0.48 01H 01H 38 33 DSI 0.61 31 P1 01H

-0.03 TEH TEC 38 34 DSI 0.67 61 P1 01H 0.08 TEH TEC 38 37 DSI 1.41 91 P1 02H 0.17 TEH TEC 38 47 DSI 1.03 137 P1 01H

-0.14 TEH TEC 38 47 SAI 1.00 90 6

011H

-0.14 0.62 01H 01H 38 52 DSI 0.73 152 P1 011H

-0.22 TEH TEC 38 52 DSI 0.57 112 P1 03H 0.08 TEH TEC 38 55 DSI 1.45 123 P1 01H

-0.08 TEH TEC 38 55 DSI 0.51 126 P1 02H 0.00 TEH TEC 38 59 DSI 1.19 129 P1 01H 0.00 TEH TEC 38 62 DSI 0.97 132 P1 01H 0.08 TEH TEC 38 62 DSI 1.05 129 P1 02H

-0.17 TEH TEC 38 62 SVI 0.41 101 2

AV3 1.81 4.65 46 07H 07C 38 63 DSI 1.80 95 P1 02H 0.08 TEH TEC 38 63 DSI 0.84 77 P1 03H 0.06 TEH TEC 38 63 MAI 0.59 88 6

03H 0.02 0.40 03H 03H 38 63 DSI 0.32 105 P1 05H 0.14 TEH TEC 38 64 DSI 0.46 54 P1 03H 0.00 TEH TEC 38 66 DSI 0.39 81 P1 02H 0.08 TEH TEC 38 66 NOI 0.92 118 3

02H 28.44 TEH TEC 38 66 MAI 0.55 96 6

02H 0.08 0.52 02H 03H 38 66 DSI 1.63 87 P1 03H 0.03 TEH TEC 38 66 MAI 0.49 92 6

03H

-0.02 0.46 02H 03H 38 66 DSI 1.20 106 P1 04H 0.00 TEH TEC 38 68 DSI 0.69 45 P1 02H 0.00 TEH TEC 38 68 SAI 0.40 74 6

02H 0.01 0.29 02H 02H 38 70 DSI 0.52 53 P1 03H 0.06 TEH TEC 38 70 SAI 0.35 95 6

03H 0.00 0.27 03H 03H 38 73 PCT 0.40 127 11 P1 01C

-0.25 TEH TEC

Beaver Valley Unit #1 1 R1 5 S/G Examination Results 1 RC-E-1 C (TUBES WITH INDICATIONS)

Page 26 of 28 Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 38 74 DSI 0.49 39 25 DSI 0.40 39 27 PCT 0.72 39 29 DSI 1.16 39 29 MAI 0.56 39 29 DSI 0.73 39 29 MAI 0.29 39 30 DSI 0.76 39 30 MAI 0.33 39 32 DSI 1.66 39 32 MAI 0.66 39 32 DSI 0.43 39 32 SAI 0.23 39 33 DNI 0.31 39 33 DSI 1.17 39 33 SAI 0.62 39 33 SAI 0.56 39 33 DSI 1.19 39 33 SAI 0.50 39 33 DSI 0.50 39 37 DSI 0.69 39 58 PCT 2.05 39 58 WAR 0.19 39 62 SSA 0.15 39 63 PCT 1.93 39 63 WAR 0.42 39 63 PCT 2.03 39 63 PCT 1.65 39 63 WAR 0.34 39 63 WAR 0.48 39 71 PCT 0.99 39 71 DSI 0.32 40 24 DSI 0.58 40 25 PCT 1.28 40 27 DSI 0.59 40 27 SAI 0.44 40 33 DSI 0.43 40 36 DSI 0.40 40 39 DSI 1.49 40 40 DSI 1.70 40 41 DSI 0.64 40 41 PCT 1.51 40 41 WAR 0.38 40 41 PCT 0.91 40 41 WAR 0.33 40 50 PCT 1.37 40 50 WAR 0.38 40 52 PCT 2.13 40 52 WAR 0.44 40 52 PCT 2.53 40 52 WAR 0.59 111 52 134 88 101 45 95 43 93 101 87 107 111 147 84 102 100 148 107 65 83 0

116 121 0

127 0

0 118 123 113 40 39 119 84 78 35 98 107 103 89 104 125 0

122 0

111 35 103 48 108 P1 02H 0.22 P1 01H

-0.08 9

P1 01C

-0.16 P1 01H

-0.06 6

01H

-0.08 P1 03H 0.03 6

03H 0.05 P1 01H 0.06 6

01H 0.00 P1 011H 0.14 6

01H 0.06 P1 02H

-0.11 6

02H 0.00 5

01H 39.14 P1 01H 0.19 6

01H 0.05 6

01H 0.01 P1 02H 0.22 6

02H

-0.07 P1 05H 0.06 P1 01H 0.03 26 P2 AV4

-0.25 P2 AV4

-0.25 3

AV3 1.05 26 P2 AV1 0.00 2

AV1 0.00 26 P2 AV2 0.49 24 P2 AV2

-0.49 2

AV2

-0.49 2

AV2 0.49 33 P1 02C

-0.03 P1 06H 0.03 P1 01H 0.00 26 P1 01C

-0.22 P1 02H 0.11 6

02H 0.04 P1 01H 0.06 P1 01H 0.08 P1 01H 0.08 P1 01H 0.03 P1 02H 0.03 22 P2 AV2

-1.00 2

AV2

-1.28 16 P2 AV3 0.00 2

AV3 0.00 21 P2 AV2 0.00 2

AV2 0.61 28 P2 AV3 0.00 2

AV3

-0.56 30 P2 AV4 0.00 2

AV4

-0.79 0.54 0.37 0.44 0.27 0.29 0.40 0.44 0.36 0.35 TEH TEC TEH TEC TEH TEC TEH TEC 01H 01H TEH TEC 03H 03H TEH TEC 01H 01H TEH TEC 01H 01H TEH TEC 02H 02H TEH TEC TEH TEC 01H 01H 01H 02H TEH TEC 01H 02H TEH TEC TEH TEC TEH TEC 07H 06C 07H 07C TEH TEC 07H 07C TEH TEC TEH TEC 07H 07C 07H 07C TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 02H 02H TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 07H 07C TEH TEC 07H 07C TEH TEC 07H 07C TEH TEC 07H 07C TEH TEC 07H 07C

Beaver Valley Unit #1 Page 27 of 28 1 R1 5 S/G Examination Results 1RC-E-1C (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inchl Cr-Length Cr-Angle From To 40 63 DSI 0.73 63 P1 02H 0.03 TEH TEC 40 66 DSI 0.35 110 P1 01H 0.08 TEH TEC 40 66 DSI 0.76 67 P1 02H

-0.06 TEH TEC 40 70 DSI 0.31 92 P1 05H 0.06 TEH TEC 41 26 DSI 0.53 55 P1 01H 0.06 TEH TEC 41 26 PCT 1.82 134 0

P1 04C 0.14 TEH TEC 41 29 DSI 0.65 130 P1 01H 0.08 TEH TEC 41 29 PCT 1.64 126 15 P1 04C 0.11 TEH TEC 41 33 DSI 0.58 107 P1 01H 0.25 TEH TEC 41 33 DSI 0.67 89 P1 02H 0.19 TEH TEC 41 34 PCT 0.50 133 6

P1 02C

-0.22 TEH TEC 41 34 VOL 0.20 116 3

02C

-0.16 02C 02C 41 34 PCT 0.41 134 5

P1 03C -0.19 TEH TEC 41 34 VOL 0.28 141 3

03C

-0.11 03C 03C 41 34 DSI 0.80 59 P1 03H 0.14 TEH TEC 41 36 DSI 0.35 59 P1 01H 0.08 TEH TEC 41 39 DSI 0.64 84 P1 01H 0.06 TEH TEC 41 39 DSI 0.37 121 P1 04H 0.06 TEH TEC 41 46 DSI 0.57 19 P1 01H 0.00 TEH TEC 41 48 DSI 0.47 33 P1 02H 0.03 TEH TEC 41 55 DSI 0.35 150 P1 02H 0.03 TEH TEC 41 56 DSI 0.76 64 P1 03H 0.03 TEH TEC 41 56 PCT 1.43 0

21 P2 AV 0.00 TEH TEC 41 56 WAR 0.25 114 2

AV 0.00 07H 07C 41 60 DSI 0.30 60 P1 03H

-0.03 TEH TEC 41 63 DSI 0.82 98 P1 02H 0.03 TEH TEC 41 66 PCT 1.33 121 29 P1 01C

-0.25 TEH TEC 41 69 PCT 0.47 126 14 P1 01C -0.25 TEH TEC 42 28 PCT 0.59 100 51 P1 04C 0.14 TEH TEC 42 28 VOL 0.21 110 3

04C 0.20 04C 04C 42 31 PCT 0.65 127 14 P1 03C -0.22 TEH TEC 42 38 DSI 0.52 122 P1 02H 0.05 TEH TEC 42 39 DSI 1.70 99 P1 01H 0.14 TEH TEC 42 39 DSI 0.53 101 P1 03H

-0.14 TEH TEC 42 39 NQI 0.33 106 3

TSC 41.37 TEH TEC 42 39 NOI 0.34 89 3

TSC 17.31 TEH TEC 42 40 PSI 6.32 107 8

01H

-0.49 TEH TEC 42 40 CSI 0.22 78 11 01H 0.23 0.64 54 01H 01H 42 42 DSI 0.63 118 P1 03H 0.08 TEH TEC 42 42 DSI 0.29 124 P1 06H 0.03 TEH TEC 42 48 NOI 0.67 96 3

01C 38.61 TEH TEC 42 52 DSI 0.48 126 P1 01H 0.05 TEH TEC 42 53 PCT 1.01 131 10 P1 02C

-0.19 TEH TEC 42 53 VOL 0.21 125 3

02C -0.13 02C 02C 43 31 PCT 0.27 126 15 P1 01C 0.05 TEH TEC 43 33 PCT 0.35 142 0

P1 01C -0.14 TEH TEC 43 33 VOL 0.08 114 3

01C -0.10 01C 01C 43 36 DSI 0.78 144 P1 03H

-0.11 TEH TEC 43 37 NOI 1.17 121 3

01C 23.65 TEH TEC 43 37 DSI 0.90 97 P1 01H 0.22 TEH TEC 43 37 NQI 0.45 82 3

02C 43.92 TEH TEC

Beaver Valley Unit #1 Page 28 of 28 1 R15 S/G Examination Results 1RC-E-1C (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 43 37 NQI 0.27 111 3

02C 7.99 TEH TEC 43 37 NQI 0.39 109 3

02C 13.85 TEH TEC 43 37 NQI 0.70 76 3

02C 5.30 TEH TEC 43 37 NOI 0.35 112 3

02C 17.91 TEH TEC 43 37 NOI 0.31 99 3

02C 38.12 TEH TEC 43 45 DSI 0.86 64 P1 02H 0.03 TEH TEC 43 45 DSI 0.34 104 P1 05H 0.06 TEH TEC 43 46 SAI 0.69 18 6

TSH

-0.37 0.19 TSH TSH 43 48 PCT 0.79 31 16 P2 AV2 0.00 TEH TEC 43 63 DSI 0.83 31 P1 02H 0.03 TEH TEC 43 63 SAI 0.21 104 6

02H 0.03 0.27 02H 02H 43 64 PCT 1.02 126 15 P1 02C

-0.11 TEH TEC 43 64 PCT 1.31 0

21 P2 AV1 0.00 TEH TEC 43 64 WAR 0.23 138 2

AVI 0.00 07H AV3 43 64 WAR 0.21 137 2

AVI 0.00 07H 07C 43 65 PCT 0.90 0

16 P2 AV1 0.00 TEH TEC 43 65 WAR 0.23 132 2

AV1 0.00 07H 07C 44 33 PCT 1.93 122 23 P1 03C

-0.25 TEH TEC 44 33 PCT 0.42 141 0

P1 04C

-0.28 TEH TEC 44 34 DSI 0.35 124 P1 01H 0.22 TEH TEC 44 34 PCT 1.27 0

20 P2 AV2 0.03 TEH TEC 44 34 WAR 0.14 129 2

AV2 0.03 07H 07C 44 36 DSI 0.54 131 P1 02H 0.25 TEH TEC 44 36 PCT 1.47 129 13 P1 03C 0.14 TEH TEC 44 39 PCT 0.89 114 34 P1 03C

-0.25 TEH TEC 44 49 PCT 0.64 125 18 P1 03C 0.11 TEH TEC 44 52 SAI 0.57 8

6 TSH

-0.24 0.16 TSH TSH 44 53 PCT 1.33 59 18 P2 AV1 0.00 TEH TEC 44 53 WAR 0.18 128 2

AV1 0.00 07H 07C 44 54 PCT 1.21 0

19 P2 AV1 0.00 TEH TEC 44 54 WAR 0.13 134 2

AV1 0.00 07H 07C 44 57 PCT 0.65 145 0

P1 01C

-0.11 TEH TEC 44 60 PCT 0.71 129 5

P1 02C

-0.19 TEH TEC 44 62 PCT 1.80 112 34 P1 01C

-0.17 TEH TEC 45 36 PCT 1.04 151 0

P1 04C 0.17 TEH TEC 45 36 VOL 0.26 148 3

04C 0.21 04C 04C 45 37 PCT 0.44 138 0

P1 04C 0.19 TEH TEC 45 50 PCT 0.32 119 17 P1 04C 0.25 TEH TEC 46 41 PSI 17.96 155 8

01H 0.00 TEH TEC 46 41 CSI 0.31 80 11 01H

-0.15 0.89 140 01H 01H 46 46 PCT 0.69 131 5

P1 03C 0.14 TEH TEC 46 53 PCT 0.64 146 0

P1 01C

-0.17 TEH TEC

ATTACHMENT 3A BEAVER VALLEY UNIT #1 lR15 S/G EXAMINATION RESULTS IRC-E-IC TUBES REMOVED FROM SERVICE

Beaver Valley Unit #1 1 RI 5 S/G Examination Results 1RC-E-1C (TUBES REMOVED FROM SERVICE)

Page 1 of 1 Row Col 1

45 1

45 1

73 2

49 2

49 2

51 3

47 3

47 7

29 7

46 7

46 7

67 8

29 9

10 9

33 9

33 10 48 10 48 11 33 12 34 12 34 12 48 13 61 14 50 14 52 17 22 23 49 24 57 26 28 26 62 27 60 28 21 28 70 30 21 30 33 31 57 35 66 38 62 39 62 42 28 43 46 44 52 Ind Volts Phase %TW Chan Loc Inchl Cr-Length Cr-Angle From To DSI 2.25 60 P1 01 H 0.00 07H TEH MAI 0.44 79 6

01H 0.11 0.36 01H 01H SAI 0.53 14 6

TSH

-0.31 0.30 TSH TSH DSI 2.04 64 P1 01H

-0.09 07H TEH SAI 0.86 93 6

01H

-0.05 0.39 01H 01H MAI 0.29 109 6

01H

-0.01 0.35 01H 01H DSI 2.25 54 P1 011H 0.00 07H TEH MAI 1.66 76 6

011H 0.07 0.58 01H 01H SAI 0.53 23 6

TSH

-0.28 0.24 TSH TSH DSI 2.24 77 P1 02H 0.06 07H TEH MAI 0.42 84 6

02H 0.06 0.50 02H 02H SVI 0.20 119 P2 07H 0.26 0.29 63 07C 07H SAI 0.25 84 6

TSH 0.23 0.30 TSH TSH SAI 0.23 69 6

02H

-0.02 0.24 02H 02H SAI 0.16 84 6

TSH 0.52 0.44 TSH TSH SAI 0.12 101 6

TSH 0.89 0.20 TSH TSH DSI 2.50 67 P1 01H 0.03 07H TEH MAI 0.99 75 6

011H 0.03 0.37 011H 01H MAI 0.15 88 6

TSH 1.06 0.32 TSH TSH SAI 0.10 68 6

TSH 2.22 0.20 TSH TSH SAI 0.18 83 6

TSH 1.60 0.46 TSH TSH SAI 0.21 91 6

011H 0.09 0.30 01H 011H SAI 1.27 12 2

07H 19.93 3.11 07C 07H NQI 0.36 91 P1 TSH 0.52 TEH TEC SAI 0.21 83 6

TSH 0.55 0.61 TSH TSH SAI 0.64 10 2

07H 4.74 0.25 07C 07H SAI 0.56 17 6

TSH

-0.49 0.20 TSH TSH SAI 0.20 85 6

TSH 0.00 0.16 TSH TSH NOI 0.25 12 P1 TSH 4.88 TEH TEC OBS 04C 04C SAI 0.58 14 6.

TSH

-0.50 0.24 TSH TSH MAI 0.89 97 6

01H

-0.06 0.49 01H 01H SAI 0.60 13 6

TSH

-2.16 0.19 TSH TSH SVI 0.17 107 6

TSH 0.28 0.57 64 TSH TSH SAI 0.75 12 6

TSH

-3.14 0.14 TSH TSH SAI 0.53 16 6

TSH

-3.63 0.21 TSH TSH SAI 0.74 14 6

TSH

-7.72 0.29 TSH TSH SVI 0.41 101 2

AV3 1.81 4.65 46 07H 07C SSA 0.15 121 3

AV3 1.05 07H 07C PCT 0.59 100 51 P1 04C 0.14 TEH TEC SAI 0.69 18 6

TSH

-0.37 0.19 TSH TSH SAI 0.57 8

6 TSH

-0.24 0.16 TSH TSH

ENCLOSURE 2 BEAVER VALLEY POWER STATION UNIT NO. 2 10TH REFUELING OUTAGE

ENCLOSURE 2 Beaver Valley Power Station Unit No. 2 10th Refueling Outage (Attachments 4 through 6A)

Procedures and Personnel The examinations and the analysis performed during the 10th refueling outage were in compliance with the Beaver Valley Power Station Unit # 2 Technical Specifications, NRC Regulatory Guide 1.83, the EPRI PWR Steam Generator Examination Guidelines, (Rev. 6) and FENOC Procedure ISIEI-8 (Rev. 8),

"Unit #2 Steam Generator Examination Guidelines". Personnel evaluating data were Qualified Data Analysts (QDA) in accordance with Appendix "G" of the EPRI PWR Steam Generator Guidelines. All analysts were required to pass a site specific performance demonstration prior to analyzing the eddy current data from the current outage. All data underwent an independent second party review prior to final acceptance.

Eddy Current Examination One hundred percent of the in-service tubes in Rows 3 through 46 from Steam Generators 2RCS-SG21A, 2RCS-SG21B and 2RCS-SG21C were examined full length with bobbin coil probes. In-service tubes in Rows 1 and 2 were examined with bobbin coil probes to the upper most tube support plate in each leg. The U-bend regions of the tubes in Rows 1 and 2 were examined with single coil Plus Point probes.

In response to issues at a plant with similar model steam generators and BVPS Unit #1 IR15 examination results, one hundred percent of the U-bend region in Rows 3 through 10 were examined with single coil Plus Point probes. In addition, a twenty percent sample of the U-bend region in Rows 12 through 18 was also examined with single coil Plus Point Probes.

One hundred percent of the hot leg top-of-tubesheet region was examined in each steam generator with Plus Point probes. Circumferential indications located at the top of the hot leg tubesheet were stabilized prior to removing the tube from service.

One hundred percent of distorted tube support plate signals (DSI's) reported by the bobbin coil were re-examined Plus Point probes. DSI's confirmed (detected) by the Plus Point Probes were repaired by tube plugging.

Plug Retainers Eighteen Westinghouse Plug-in-Plug (PIP) retainers were visually examined during 2R10. No indications were observed.

Tube Sleeves There are no tube sleeves installed at Unit 2.

In-Situ Pressure Testing Based on the 2R10 eddy current results, In-situ testing was not required.

ENCLOSURE 2 (cont.)

Beaver Valley Power Station Unit No. 2 10th Refueling Outage (Attachments 4 through 6A)

Examination Summary The following table summarizes the number of tubes examined and the number of tubes removed from service.

2RCS-SG21A I 2RCS-SG21B I 2RCS-SG21C TUBES EXAMINED (BOBBIN) 3252 3263 3274 TUBES REMOVED FROM SERVICE 13 13 20 Notes for tubes removed from service 2R10:

A total of five tubes (2 in 2RCS-SG21B, 3 in 2RCS-SG21C) were preventatively removed from service during 2R10. These locations were determined to be susceptible to high cycle fatigue during the planned power up-rate for Unit 2.

A total of five tubes (1 in 2RCS-SG21A, 4 in 2RCS-SG21C) were removed from service due to the inability to collect quality data in portions of the U-bend. This was attributed to "probe snap" during the

+Point inspection of the U-bends.

One tube (R45 C57) in 2RCS-SG21C was administratively removed from service due to a possible loose part signal located on the first tube support plate on the cold leg side.

ENCLOSURE 2 (Cont.)

Beaver Valley Power Station Unit No. 2 10th Refueling Outage (Attachments 4 through 6A)

The results of the Unit 2 steam generator eddy current examinations are provided in the following Attachments: - A - - A - - A -

Beaver Valley Unit #2 2R10 SIG Examination Results 2RCS-SG21A Tubes with Indications Beaver Valley Unit #2 2R10 S/G Examination Results 2RCS-SG21A Tubes Removed From Service Beaver Valley Unit #2 2R10 S/G Examination Results 2RCS-SG21B Tubes with Indications Beaver Valley Unit #2 2R10 S/G Examination Results 2RCS-SG21B Tubes Removed From Service Beaver Valley Unit #2 2R10 S/G Examination Results 2RCS-SG21C Tubes with Indications Beaver Valley Unit #2 2R10 S/G Examination Results 2RCS-SG21C Tubes Removed From Service

ATTACHMENT 4 BEAVER VALLEY UNIT #2 2R10 SIG EXAMINATION RESULTS 2RCS-SG21A TUBES WITH INDICATIONS

Beaver Valley Unit #2 Page 1 of 5 2R10 S/G Examination Results 2RCS-SG21 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inchl Cr-Length Cr-Angle From To 1

44 SCI 0.14 123 P2 TSH

-0.08 113 TSH TSH 1

53 DSI 0.33 81 P1 06H

-0.03 08H TEH 2

42 SCI 0.15 100 P2 TSH 0.00 53 TSH TSH 2

59 NQI 0.70 112 3

06C 40.35 08C TEC 2

87 NOI 0.92 115 3

05C 26.47 08C TEC 2

92 DSI 0.43 91 P1 03H

-0.09 08H TEH 3

15 DSI 0.67 84 P1 03H 0.00 08H TEH 3

15 DSI 0.61 88 P1 03H 0.05 08C TEH 3

23 NQI 0.42 103 3

03H 10.37 08H TEH 3

24 DSI 1.02 70 P1 03H

-0.17 08H TEH 3

24 DS) 0.99 66 P1 03H

-0.19 08C TEH 3

44 SAI 0.13 94 6

TSH 0.55 0.17 TSH TSH 3

59 DSI 0.76 64 P1 02H 0.14 08H TEH 3

59 DSI 0.73 65 P1 02H 0.10 08C TEH 3

81 DSI 1.16 67 P1 03H

-0.03 08H TEH 3

81 DSI 0.98 77 P1 03H 0.00 08C TEH 3

84 DSI 0.87 69 P1 03H

-0.06 08H TEH 3

84 DSI 0.77 55 P1 03H

-0.02 08C TEH 3

85 DSI 0.70 65 P1 04H 0.06 08H TEH 3

85 DSI 0.59 66 P1 04H 0.02 08C TEH 3

92 DSI 0.36 110 P1 02H 0.03 08H TEH 3

92 DSI 0.57 101 P1 02H 0.07 08C TEH 4

9 DSI 0.57 96 P1 03H 0.03 08H TEH 4

.9 DSI 0.70 84 P1 03H 0.00 08C TEH 4

18 DSI 1.02 42 P1 05H 0.12 08H TEH 4

18 DSI 0.99 37 P1 05H 0.14 08C TEH 4

21 DSI 0.75 60 P1 03H

-0.09 08H TEH 4

21 DSI 0.87 60 P1 03H 0.00 08C TEH 4

26 DSI 0.59 62 P1 02H 0.00 08H TEH 4

26 DSI 0.59 67 P1 02H

-0.03 08C TEH 4

30 DSI 0.39 113 P1 04H

-0.03 08H TEH 4

30 DSI 0.32 100 P1 04H

-0.05 08C TEH 4

50 DSI 0.67 82 P1 02H 0.00 08H TEH 4

50 DSI 0.64 84 P1 02H 0.00 08C TEH 4

50 DSI 0.66 54 P1 03H 0.00 08C TEH 4

50 DSI 0.61

62.

P1 04H 0.00 08C TEH 4

54 DSI 1.22 80 P1 02H

-0.03 08H TEH 4

54 DSI 0.62 73 P1 04H 0.00 08H TEH 4

54 DSI 0.80 72 P1 02H 0.00 080 TEH 4

54 DSI 0.56 74 P1 04H 0.00 08C TEH 4

54 DSI 0.42 87 P1 05H 0.02 08C TEH 4

58 DSI 0.87 43 P1 02H

-0.03 08H TEH 4

58 DSI 0.80 39 P1 02H

-0.10 08C TEH 4

60 DSI 0.72 104 P1 02H 0.06 08H TEH 4

60 DSI 1.01 105 P1 02H 0.07 08C TEH 4

63 DSI 0.66 66 P1 02H

-0.06 08H TEH 4

63 DSI 0.83 70 P1 02H

-0.07 08C TEH 4

78 DSI 0.35 94 P1 05H 0.00 08H TEH 4

78 DSI 0.34 81 P1 05H 0.00 08C TEH 4

85 DSI 0.39 35 P1 08C 0.00 08C TEH 4

85 DSI 0.29 36 P1 08C -0.05 08C TEC

Beaver Valley Unit #2 Page 2 of 5 2R10 S/G Examination Results 2RCS-SG21 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inchl Cr-Length Cr-Angle From To 5

10 DSI 1.47 60 P1 02H 0.00 TEH TEC 5

10 DSI 0.71 81 P1 03H 0.00 TEH TEC 5

11 DSI 0.37 54 P1 04H 0.08 TEH TEC 5

25 DSI 0.39 84 P1 05H 0.05 TEH TEC 5

26 DSI 0.62 81 P1 03H

-0.02 TEH TEC 5

39 SC0 0.57 79 P2 TSH

-0.07 189 TSH TSH 5

54 DSI 0.47 89 P1 02H

-0.06 08H TEH 5

71 DSI 0.59 90 P1 02H 0.02 TEH TEC 5

80 DSI 0.34 70 P1 05H 0.10 TEH TEC 5

82 DSI 0.30 68 P1 03H 0.00 TEH TEC 6

17 DSI 1.19 57 P1 04H 0.14 TEH TEC 6

32 DSI 0.62 91 P1 02H 0.05 TEH TEC 6

34 DSI 0.64 114 P1 02H 0.06 TEH TEC 6

40 DSI 0.56 90 P1 03H 0.08 TEH TEC 6

43 DSI 0.94 67 P1 02H 0.08 TEH TEC 6

54 SCI 0.12 60 P2 TSH 0.06 45 TSH TSH 7

19 DSI 0.63 48 P1 03H 0.09 TEH TEC 7

27 DSI 0.39 149 P1 05H 0.12 TEH TEC 7

51 DSI 0.50 31 P1 02H

-0.03 08H TEH 7

58 DSI 1.10 62 P1 03H

-0.06 08H TEH 7

71 DSI 0.41 84 P1 03H

-0.03 TEH TEC 7

94 DSI 0.28 89 P1 02H 0.11 TEH TEC 8

19 DSI 0.47 113 P1 02H 0.00 TEH TEC 8

29 DSI 0.49 109 P1 02H 0.00 TEH TEC 8

34 DSI 1.34 48 P1 03H

-0.17 TEH TEC 8

42 NQI 0.15 62 3

05H 13.76 08H TEH 8

42 NOI 0.30 72 3

05H 15.12 08H TEH 8

42 NOI 0.36 67 3

05H 16.62 08H TEH 9

14 DSI 0.73 67 P1 03H 0.03 TEH TEC 9

16 DSI 0.61 111 P1 02H 0.00 TEH TEC 9

16 DSI 0.68 52 P1 03H 0.11 TEH TEC 9

16 DSI 0.58 125 P1 04H 0.00 TEH TEC 9

22 DSI 1.33 71 P1 03H

-0.14 TEH TEC 9

35 DSI 0.41 102 P1 02H 0.00 08H TEH 9

38 DSI 0.86 57 P1 05H 0.20 08H TEH 9

40 DSI 0.95 57 P1 03H 0.20 08H TEH 9

57 DSI 0.19 93 P1 02H 0.00 08H TEH 9

57 DSI 0.77 70 P1 03H

-0.06 08H TEH 9

57 DSI 0.96 44 P1 04H 0.12 08H TEH 9

61 SCI 0.19 78 P2 TSH

-0.04 79 TSH TSH 9

66 PVN 10.24 185 P1 04H

-0.11 TEH TEC 10 8

DSI 1.02 60 P1 03H

-0.03 TEH TEC 10 19 DSI 0.65 62 P1 04H 0.03 TEH TEC 10 29 DSI 1.43 74 P1 03H 0.00 TEH TEC 10 35 RBD 08H 08C 10 37 DSI 0.48 104 P1 03H 0.00 08H TEH 10 44 SCI 0.20 100 P2 TSH

-0.03 60 TSH TSH 11 45 SCI 0.18 119 P2 TSH

-0.06 56 TSH TSH 11 48 DSI 1.19 47 P1 02H 0.00 08H TEH 11 77 DSI 0.46 63 P1 05H 0.11 TEH TEC 12 15 DSI 0.31 43 P1 03H 0.06 TEH TEC

Beaver Valley Unit #2 Page 3 of 5 2R10 S/G Examination Results 2RCS-SG21 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 12 46 NQI 0.51 111 3

TSC 25.86 08H TEC 12 70 DSI 0.55 85 P1 03H 0.11 TEH TEC 12 74 DSI 0.51 49 P1 03H

-0.03 TEH TEC 13 32 DSI 0.54 94 P1 02H

-0.06 TEH TEC 13 39 DSI 0.86 110 P1 03H

-0.17 08H TEH 13 39 DSI 0.78 45 P1 05H 0.32 08H TEH 13 49 DSI 0.30 59 P1 04H 0.09 TEH TEC 13 84 DSI 0.70 43 P1 02H 0.05 TEH TEC 13 85 DSI 0.88 65 P1 02H 0.11 TEH TEC 14 20 DSI 0.43 69 P1 03H 0.06 TEH TEC 14 25 DSI 0.47 74 P1 05H 0.17 TEH TEC 14 27 DSI 0.54 132 P1 05H 0.14 TEH TEC 14 53 DSI 0.41 42 P1 02H 0.07 TEH TEC 14 68 DSI 0.76 54 P1 02H 0.05 TEH TEC 14 70 DSI 0.84 90 P1 03H 0.00 TEH TEC 15 74 DSI 1.90 44 P1 03H

-0.14 TEH TEC 16 8

DSI 0.74 59 P1 03H 0.00 TEH TEC 16 42 NQI 0.42 97 3

03H 41.97 08H TEH 16 59 DSI 1.05 58 P1 04H

-0.25 TEH TEC 17 27 DSI 0.33 54 P1 04H 0.11 TEH TEC 17 32 DSI 1.08 59 P1 05H 0.26 TEH TEC 17 59 DSI 0.53 103 P1 02H 0.16 TEH TEC 18 7

DSI 0.41 95 P1 04H 0.09 TEH TEC 18 26 NQI 0.32 97 3

02C 14.68 TEH TEC 18 38 DSI 0.44 100 P1 02H

-0.06 08H TEH 18 47 DSI 1.20 54 P1 05H 0.20 08H TEH 19 7

DSI 0.66 82 P1 02H 0.03 TEH TEC 19 8

DSI 0.50 107 P1 03H

-0.03 TEH TEC 19 56 DSI 1.21 50 P1 03H

-0.11 TEH TEC 19 60 DSI 0.48 63 P1 02H 0.05 TEH TEC 20 62 DSI 0.64 144 P1 05H

-0.05 TEH TEC 20 64 PCT 0.63 0

12 P2 AVI 0.00 TEH TEC 20 64 PCT 1.13 0

18 P2 AV2 0.00 TEH TEC 20 64 PCT 0.81 0

14 P2 AV3 0.00 TEH TEC 20 78 DSI 0.42 81 P1 04H 0.08 TEH TEC 21 18 DSI 0.26 104 P1 04H 0.09 TEH TEC 21 26 DSI 0.53 67 P1 05H 0.03 TEH TEC 21 34 DSI 0.39 83 P1 02H 0.06 TEH TEC 21 72 DSI 0.42 66 P1 03H 0.00 TEH TEC 22 7

DSI 0.50 92 P1 02H 0.08 TEH TEC 22 21 DSI 0.47 103 P1 03H 0.09 TEH TEC 23 11 DSI 0.44 40 P1 02H 0.00 TEH TEC 23 11 DSI 0.38 76 P1 03H 0.06 TEH TEC 23 19 DSI 0.98 41 P1 02H 0.06 TEH TEC 23 20 DSI 0.35 92 P1 02H

-0.03 TEH TEC 24 16 DSI 0.38 139 P1 02H 0.08 TEH TEC 24 16

'DSI 0.28 101 P1 03H 0.08 TEH TEC 24 24 DSI 0.29 65 P1 02H 0.06 TEH TEC 24 33 DSI 0.43 59 P1 03H 0.09 TEH TEC 25 21 DSI 0.34 51 P1 02H 0.14 TEH TEC 26 15 DSI 0.35 83 P1 03H 0.08 TEH TEC

Beaver Valley Unit #2 Page 4 of 5 2R10 S/G Examination Results 2RCS-SG21 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 26 42 DSI 0.54 87 P1 02H 0.00 TEH TEC 27 21 DSI 0.23 59 P1 02H 0.03 TEH TEC 27 32 DSI 0.31 95 P1 02H 0.06 TEH TEC 27 64 DSI 0.39 43 P1 02H 0.05 TEH TEC 27 71 PCT 1.08 0

17 P2 AV2

-0.03 TEH TEC 27 71 PCT 1.12 0

17 P2 AV3 0.03 TEH TEC 27 72 PCT 1.69 0

23 P2 AV1

-0.21 TEH TEC 27 75 DSI 0.20 110 P1 05H 0.00 TEH TEC 28 13 DSI 0.36 117 P1 03H 0.09 TEH TEC 28 26 DSI 0.78 58 P1 04H 0.06 TEH TEC 28 46 DSI 0.36 48 P1 03H 0.00 TEH TEC 28 54 DSI 0.23 103 P1 02H 0.00 TEH TEC 29 19 DSI 0.43 37 P1 02H 0.00 TEH TEC 29 33 NQI 0.36 82 3

01H 2.74 TEH TEC 29 65 DS1 0.80 28 P1 02H 0.13 TEH TEC 30 19 DSI 0.98 46 P1 02H 0.03 TEH TEC 30 22 DSI 0.64 66 P1 02H 0.00 TEH TEC 30 28 DSI 0.38 107 P1 03H 0.06 TEH TEC 30 51 DSI 0.54 70 P1 04H 0.00 TEH TEC 31 14 DSI 0.42 130 P1 04H 0.11 TEH TEC 31 18 DSI 1.16 57 P1 02H 0.03 TEH TEC 31 18 DSI 0.54 59 P1 03H 0.06 TEH TEC 31 26 NOI 0.35 112 3

05H 5.95 TEH TEC 31 34 NOI 0.46 77 3

04H 44.06 TEH TEC 31 47 DSI 0.53 135 P1 02H 0.17 TEH TEC 31 68 PCT 1.78 0

24 P2 AV3 0.40 TEH TEC 31 69 PCT 0.57 0

10 P2 AV3 0.00 TEH TEC 32 22 DSI 0.42 63 P1 02H 0.06 TEH TEC 32 27 DSI 0.29 31 P1 03H 0.06 TEH TEC 32 45 DSI 0.58 45 P1 02H 0.08 TEH TEC 32 51 DSI 0.80 71 P1 02H 0.11 TEH TEC 33 18 DSI 0.32 110 P1 02H 0.08 TEH TEC 33 18 DSI 0.40 71 P1 03H 0.00 TEH TEC 33 66 DSI 0.47 32 P1 02H 0.05 TEH TEC 33 70 PCT 1.10 0

17 P2 AVi

-0.27 TEH TEC 34 48 PCT 2.47 0

29 P2 AV3 0.00 TEH TEC 34 53 DSI 0.74 51 P1 02H 0.00 TEH TEC 34 56 DSI 0.33 26 P1 05H 0.05 TEH TEC 34 67 MCI 0.37 63 P2 TSH

-0.05 90 TSH TSH 34 68 SAI 0.13 104 6

TSH 0.31 0.17 TSH TSH 34 70 PCT 1.15 0

17 P2 AV2 0.11 TEH TEC 34 70 PCT 1.32 0

19 P2 AV3 0.22 TEH TEC 35 36 DSI 1.06 57 P1 03H

-0.24 TEH TEC 35 38 DSI 1.21 47 P1 06H 0.11 TEH TEC 35 40 DSI 0.84 50 P1 06H 0.29 TEH TEC 35 45 DSI 0.62 47 P1 02H 0.11 TEH TEC 35 70 PCT 0.69 0

12 P2 AV3

-0.24 TEH TEC 35 72 PCT 1.45 0

21 P2 AV1

-0.38 TEH TEC 35 72 PCT 1.09 0

16 P2 AV3 0.08 TEH TEC 36 28 DSI 0.74 66 P1 03H 0.00 TEH TEC 36 28 DSI 1.29 55 P1 04H 0.00 TEH TEC

Beaver Valley Unit #2 Page 5 of 5 2R10 S/G Examination Results 2RCS-SG21 A (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 36 40 DSI 1.22 54 P1 03H

-0.19 TEH TEC 36 44 DSI 0.46 62 P1 03H

-0.03 TEH TEC 37 39 DSI 0.85 33 P1 03H 0.08 TEH TEC 37 42 DSI 1.25 57 P1 03H

-0.21 TEH TEC 37 56 DSI 0.58 57 P1 03H 0.00 TEH TEC 39 23 DSI 1.40 18 P1 02H 0.05 TEH TEC 39 42 DSI 0.85 71 P1 02H 0.11 TEH TEC 39 44 DSI 1.72 41 P1 05H 0.14 TEH TEC 39 55 PSI 10.79 135 8

O1H

-0.18 TEH TEC 39 55 CSI 0.38 164 9

01H 0.02 01H 01H 40 37 DSI 1.11 66 P1 03H 0.05 TEH TEC 40 40 DSI 0.58 48 P1 03H

-0.08 TEH TEC 40 46 SCI 0.33 57 P2 TSH

-0.04 250 TSH TSH 40 66 PCT 0.87 0

13 P2 AVi 0.00 TEH TEC 40 69 PCT 1.25 0

19 P2 AV3 0.00 TEH TEC 42 64 DSI 0.49 55 P1 04H 0.08 TEH TEC 43 57 PCT 0.87 0

14 P2 AV1 0.00 TEH TEC 44 42 PCT 1.58 0

22 P2 AV2

-0.27 TEH TEC 44 48 PCT 1.42 0

20 P2 AVI 0.00 TEH TEC 44 48 PCT 0.96 0

15 P2 AV2 0.00 TEH TEC 44 55 PCT 1.35 0

19 P2 AV4 0.00 TEH TEC 44 58 DSI 0.27 30 P1 06H 0.00 TEH TEC 45 55 PSI 12.65 140 8

01C 0.00 TEH TEC

ATTACHMENT 4A BEAVER VALLEY UNIT #2 2R10 S/G EXAMINATION RESULTS 2RCS-SG21A TUBES REMOVED FROM SERVICE

Beaver Valley Unit #2 Page 1 of 1 2R10 S/G Examination Results 2RCS-E-21 A (TUBES REMOVED FROM SERVICE)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 1

44 SCI 0.14 123 P2 TSH

-0.08 113 TSH TSH 2

42 SCI 0.15 100 P2 TSH 0.00 53 TSH TSH 3

44 SAI 0.13 94 6

TSH 0.55 0.17 TSH TSH 5

39 SCI 0.57 79 P2 TSH

-0.07 189 TSH TSH 6

54 SCI 0.12 60 P2 TSH 0.06 45 TSH TSH 9

61 SCI 0.19 78 P2 TSH

-0.04 79 TSH TSH 9

66 PVN 10.24 185 P1 04H

-0.11 TEH TEC 10 35 REJECTED FOR BAD DATA (U-BEND) 08H 08C 10 44 SCI 0.20 100 P2 TSH

-0.03 60 TSH TSH 11 45 SCI 0.18 119 P2 TSH

-0.06 56 TSH TSH 34 67 MCI 0.37 63 P2 TSH

-0.05 90 TSH TSH 34 68 SAI 0.13 104 6

TSH 0.31 0.17 TSH TSH 40 46 SCI 0.33 57 P2 TSH

-0.04 250 TSH TSH

ATTACHMENT 5 BEAVER VALLEY UNIT #2 2R10 S/G EXAMINATION RESULTS 2RCS-SG21B TUBES WITH INDICATIONS

Beaver Valley Unit #2 Page 1 of 7 2R10 S/G Examination Results 2RCS-SG21 B (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 1

52 DSI 0.40 78 P1 02H

-0.06 08H TEH 1

56 DSI 0.43 52 P1 02H 0.00 08H TEH 1

57 DSI 0.55 37 P1 04H 0.00 08H TEH 2

20 DSI 0.45 67 P1 03H

-0.03 08H TEH 2

24 DSI 0.24 56 P1 02H

-0.03 08H TEH 2

28 DSI 0.55 60 P1 02H

-0.03 08H TEH 2

30 PVN 1.06 30 P2 08H 5.00 08H 08C 2

54 DSI 0.50 74 P1 04H

-0.03 08H TEH 2

62 DSI 0.80 62 P1 03H 0.20 08H TEH 2

63 DSI 0.26 81 P1 04H

-0.09 08H TEH 2

67 DSI 0.43 70 P1 06H 0.06 08H TEH 3

54 DSI 0.51 97 P1 02H 0.03 08H TEH 3

60 DSI 0.51 68 P1 02H

-0.03 08H TEH 3

60 DSI 0.49 104 P1 03H 0.03 08H TEH 3

61 DSI 1.51 38 P1 02H

-0.03 08H TEH 3

63 DSI 0.86 65 P1 02H

-0.03 08H TEH 3

63 DSI 0.52 75 P1 03H 0.00 08H TEH 3

72 DSI 0.53 63 P1

'03H 0.00 08H TEH 3

88 DSI 0.72 65 P1 04H 0.00 08H TEH 3

89 DSI 0.49 71 P1 04H

-0.03 08H TEH 4

23 DSI 0.40 114 P1 02H 0.09 08H TEH 4

43 DSI 0.22 55 P1 02H

-0.03 08H TEH 4

48 DSI 0.47 78 P1 03H 0.00 08H TEH 4

54 DSI 0.59 89 P1 02H 0.00 08H TEH 4

56 DSI 0.54 96 P1 04H 0.03 08H TEH 4

57 DSI 0.48 88 P1 02H 0.00 08H TEH 4

57 DSI 0.35 101 P1 04H

-0.03 08H TEH 4

58 DSI 0.98 104 P1 02H 0.06 08H TEH 4

67 NOI 0.50 109 3

05C 37.15 08H TEC 4

91 NQI 0.28 111 3

03C 33.95 08H TEC 4

93 NQI 0.43 112 3

02H 9.82 08H TEH 5

9 DSI 0.69 94 P1 02H 0.03 TEH TEC 5

20 DSI 0.77 59 P1 03H 0.06 TEH TEC 5

22 DSI 0.81 55 P1 04H 0.00 TEH TEC 5

28 DSI 0.42 64 P1 02H 0.00 TEH TEC 5

52 DSI 0.80 56 P1 02H

-0.03 08H TEH 5

56 DSI 0.77 45 P1 03H

-0.03 08H TEH 5

58 DSI 0.33 88 P1 02H 0.00 08H TEH 5

60 DSI 0.40 64 P1 02H

-0.03 08H TEH 5

73 DSI 0.53 58 P1 02H 0.03 TEH TEC 6

16 DSI 0.59 79 P1 03H 0.03 TEH TEC 6

26 DSI 0.33 62 P1 02H 0.08 TEH TEC 6

52 DSI 0.46 98 P1 02H

-0.06 08H TEH 6

53 DSI 0.69 40 P1 02H 0.00 08H TEH 6

58 DSI 0.61 82 P1 02H

-0.03 08H TEH 7

12 DSI 0.35 125 P1 03H 0.06 TEH TEC 7

63 DSI 0.48 55 P1 03H 0.06 TEH TEC 8

2 DSI 1.34 75 P1 03H 0.08 TEH TEC 8

9 DSI 0.38 105 P1 02H 0.06 TEH TEC 8

15 DSI 0.78 72 P1 02H

-0.08 TEH TEC 8

18 DSI 0.45 58 P1 02H 0.00 TEH TEC

Beaver Valley Unit #2 Page 2 of 7 2R1 0 S/G Examination Results 2RCS-SG21 B (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inchl Cr-Length Cr-Angle From To 8

18 DSI 0.31 70 P1 03H 0.06 TEH TEC 8

22 DSI 0.39 123 P1 02H 0.06 TEH TEC 8

32 DSI 0.34 32 P1 03H 0.00 TEH TEC 8

41 SCI 0.52 121 P2 TSH

-0.07 148 TSH TSH 8

42 SCI 0.21 93 P2 TSH

-0.03 78 TSH TSH 8

55 DSI 0.40 103 P1 02H 0.06 08H TEH 8

56 DSI 0.50 69 P1 03H

-0.06 08H TEH 9

11 DSI 0.60 92 P1 02H 0.06 TEH TEC 9

11 DSI 0.35 55 P1 03H 0.03 TEH TEC 9

16 DSI 0.70 65 P1 03H 0.00 TEH TEC 9

17 DSI 1.18 76 P1 02H 0.08 TEH TEC 9

18 DSI 0.59 84 P1 02H 0.03 TEH TEC 9

26 DSI 0.94 86 P1 02H 0.14 TEH TEC 9

26 DSI 0.82 50 P1 03H 0.09 TEH TEC 9

46 DSI 0.32 72 P1 03H 0.00 08H TEH 9

52 DSI 0.35 54 P1 02H 0.03 08H TEH 9

52 DSI 0.42 57 P1 03H 0.00 08H TEH 9

59 DSI 0.63 66 P1 03H 0.00 08H TEH 9

92 DSI 0.58 92 P1 02H 0.06 TEH TEC 10 6

DSI 0.80 109 P1 02H 0.03 TEH TEC 10 14 DSI 0.41 61 P1 02H 0.08 TEH TEC 10 17 DSI 1.21 106 P1 02H

-0.14 TEH TEC 10 32 DSI 0.74 105 P1 03H 0.06 TEH TEC 10 52 DSI 0.88 81 P1 02H

-0.03 08H TEH 10 53 DSI 1.29 108 P1 02H 0.20 08H TEH 10 62 NOI 0.34 96 3

04C 24.63 TEH TEC 10 62 SVI 0.22 87 6

04C 24.51 0.27 56 04C 05C 10 63 DSI 0.85 64 P1 02H 0.03 TEH TEC 10 89 DSI 0.68 62 P1 02H 0.06 TEH TEC 11 3

DSI 0.41 105 P1 03H 0.09 TEH TEC 11 3

HIGH CYCLE FATIGUE (POWER UPRATE)

TEH TEC 11 4

HIGH CYCLE FATIGUE (POWER UPRATE)

TEH TEC 11 8

DSI 0.74 79 P1 03H 0.06 TEH TEC 11 18 DSI 0.84 74 P1 02H 0.06 TEH TEC 11 19 DSI 0.52 66 P1 03H 0.00 TEH TEC 11 20 DSI 0.86 84 P1 02H 0.08 TEH TEC 11 48 DSI 0.28 84 P1 03H 0.00 08H TEH 11 53 DSI 0.32 69 P1 02H

-0.06 08H TEH 11 59 DSI 0.44 90 P1 02H 0.00 08H TEH 11 59 DSI 0.62 48 P1 03H

-0.03 08H TEH 11 60 DSI 0.33 87 P1 02H

-0.06 08H TEH 11 61 DSI 1.42 70 P1 02H

-0.11 TEH TEC 11 61 DSI 0.32 65 P1 03H 0.17 TEH TEC 11 75 DSI 1.14 63 P1 02H 0.00 TEH TEC 12 10 DSI 0.41 94 P1 02H 0.06 TEH TEC 12 15 DSI 1.13 73 P1 02H

-0.17 TEH TEC 12 15 DSI 0.58 87 P1 03H 0.00 TEH TEC 12 22 DSI 0.41 128 P1 02H 0.06 TEH TEC 12 24 DSI 0.34 117 P1 04H 0.06 TEH TEC 12 61 DS!

1.02 34 P1 03H 0.06 TEH TEC 13 16 DSI 0.53 102 P1 02H 0.03 TEH TEC

Beaver Valley Unit #2 Page 3 of 7 2R10 S/G Examination Results 2RCS-SG21 B (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 13 37 DSI 0.57 68 P1 03H 0.00 08H TEH 13 54 DSI 0.40 82 P1 03H 0.00 TEH TEC 13 56 DSI 0.83 99 P1 03H 0.00 TEH TEC 13 73 DSI 0.16 79 P1 02H 0.08 TEH TEC 13 78 DSI 0.59 90 P1 02H

-0.03 TEH TEC 13 85 DSI 0.58 80 P1 02H 0.11 TEH TEC 13 86 DSI 0.42 86 P1 02H 0.08 TEH TEC 14 8

DSI 0.51 134 P1 03H 0.00 TEH TEC 14 15 DSI 0.46 62 P1 03H 0.06 TEH TEC 14 27 DSI 0.32 54 P1 03H 0.11 TEH TEC 14 32 DSI 0.85 86 P1 02H 0.22 TEH TEC 14 36 DSI 0.65 70 P1 03H 0.00 08H TEH 14 45 NQI 0.77 109 3

TSH 7.27 08H TEH 14 54 DSI 0.43 76 P1 03H 0.03 TEH TEC 14 61 DSI 0.53 103 P1 02H 0.00 TEH TEC 14 61 DSI 0.87 78 P1 03H 0.03 TEH TEC 14 88 DSI 0.42 55 P1 02H 0.00 TEH TEC 15 12 DSI 0.36 85 P1 03H 0.08 TEH TEC 15 26 DSI 0.48 82 P1 03H 0.06 TEH TEC 15 36 DSI 1.54 31 P1 03H

-0.12 08H TEH 15 52 DSI 0.81 56 P1 02H 0.00 TEH TEC 15 87 DSI 0.50 89 P1 02H 0.11 TEH TEC 16 27 DSI 0.41 69 P1 03H

-0.03 TEH TEC 16 30 PCT 0.73 0

13 P2 AV2 0.00 TEH TEC 16 31 DSI 0.45 78 P1 02H 0.19 TEH TEC 16 37 DSI 0.50 59 P1 02H 0.15 08H TEH 16 61 DSI 0.36 72 P1 02H 0.03 TEH TEC 17 30 DSI 0.39 63 P1 02H 0.06 TEH TEC 17 33 DSI 0.57 102 P1 02H 0.14 TEH TEC 17 34 DSI 1.52 76 P1 02H 0.00 TEH TEC 17 39 DSI 1.10 59 P1 03H

-0.20 08H TEH 17 42 DSI 1.13 85 P1 03H 0.20 08H TEH 17 64 DSI 0.33 91 P1 02H 0.03 TEH TEC 17 68 DSI 0.41 104 P1 02H 0.06 TEH TEC 17 84 DSI 1.86 53 P1 04H 0.25 TEH TEC 18 12 DSI 0.29 48 P1 03H 0.06 TEH TEC 18 18 DSI 0.38 74 P1 02H 0.11 TEH TEC 18 28 DSI 0.41 140 P1 04H 0.08 TEH TEC 18 29 DSI 1.34 61 P1 02H

-0.08 TEH TEC 18 31 DSI 0.53 113 P1 02H 0.00 TEH TEC 18 36 DSI 1.09 61 P1 03H

-0.20 08H TEH 18 58 DSI 0.76 89 P1 02H 0.00 TEH TEC 18 64 DSI 1.15 65 P1 03H 0.14 TEH TEC 18 76 DSI 0.37 79 P1 03H 0.00 TEH TEC 19 15 DSI 0.79 96 P1 02H 0.17 TEH TEC 19 27 SCI 0.06 82 P2 TSH

-0.03 52 TSH TSH 19 29 DSI 1.10 82 P1 02H 0.00 TEH TEC 19 29 DSI 0.92 61 P1 03H 0.00 TEH TEC 19 36 DSI 0.77 73 P1 02H 0.00 08H TEH 19 39 DSI 0.65 58 P1 03H

-0.09 08H TEH 19 50 DSI 0.78 51 P1 03H 0.14 TEH TEC

Beaver Valley Unit #2 Page 4 of 7 2R10 S/G Examination Results 2RCS-SG21 B (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 19 76 DSI 0.93 93 P1 02H 0.00 TEH TEC 19 85 DSI 0.48 95 P1 02H 0.11 TEH TEC 20 11 DSI 1.39 34 P1 02H 0.08 TEH TEC 20 16 DSI 0.44 69 P1 03H 0.00 TEH TEC 20 23 DSI 1.80 79 P1 02H 0.03 TEH TEC 20 81 DSI 0.43 117 P1 02H 0.00 TEH TEC 21 54 DSI 1.32 53 P1 02H 0.00 TEH TEC 21 75 DSI 1.12 95 P1 02H 0.00 TEH TEC 22 53 DSI 0.39 103 P1 02H

-0.03 TEH TEC 22 58 DSI 0.36 120 P1 02H 0.08 TEH TEC 23 33 DSI 0.33 48 P1 03H 0.06 TEH TEC 23 56 DSI 0.90 115 P1 02H 0.00 TEH TEC 23 76 DSI 1.31 51 P1 03H 0.25 TEH TEC 23 86 PCT 2.00 0

26 P2 AV3 0.25 TEH TEC 23 87 NQI 0.31 124 P1 01C 0.41 TEH TEC 23 87 SVI 0.34 126 6

01C 0.34 0.35 79 01C 01C 23 88 NOI 0.54 104 P1 01C 0.41 TEH TEC 23 88 SVI 0.50 82 6

01C 0.68 0.65 83 01C 01C 24 27 SAI 0.19 80 6

TSH 0.10 0.27 TSH TSH 24 30 DSI 0.35 88 P1 03H 0.08 TEH TEC 24 42 DSI 0.72 73 P1 02H 0.00 TEH TEC 24 56 DSI 0.45 87 P1 02H 0.00 TEH TEC 24 62 DSI 0.75 64 P1 03H 0.08 TEH TEC 24 73 SCI 0.11 102 P2 TSH

-0.07 89 TSH TSH 25 17 DSI 0.28 88 P1 02H 0.03 TEH TEC 25 23 PCT 0.92 0

15 P2 AV3 0.00 TEH TEC 25 29 DSI 0.48 64 P1 02H 0.08 TEH TEC 26 30 DSI 0.42 50 P1 03H 0.06 TEH TEC 26 46 NOI 0.64 110 3

TSH 12.06 TEH TEC 26 78 DSI 0.49 62 P1 02H 0.08 TEH TEC 27 46 DSI 0.20 51 P1 06H 0.06 TEH TEC 27 68 DSI 0.27 91 P1 02H 0.14 TEH TEC 28 41 DSI 0.36 69 P1 02H 0.00 TEH TEC 28 70 PCT 1.52 0

21 P2 AV3

-0.06 TEH TEC 28 70 PCT 1.31 0

19 P2 AV4

-0.19 TEH TEC 28 71 SCI 0.12 104 P2 TSH

-0.07 59 TSH TSH 28 81 DSI 0.33 76 P1 02H 0.05 TEH TEC 29 27 DSI 0.84 61 P1 03H 0.03 TEH TEC 29 31 DSI 0.41 95 P1 05H 0.03 TEH TEC 29 32 DSI 0.32 79 P1 03H 0.03 TEH TEC 29 34 DSI 1.00 74 P1 03H 0.14 TEH TEC 29 37 DSI 0.64 40 P1 03H 0.06 TEH TEC 29 38 DSI 0.39 101 P1 02H 0.11 TEH TEC 29 40 DSI 0.64 66 P1 03H 0.06 TEH TEC 29 41 DSI 0.58 70 P1 02H 0.03 TEH TEC 29 53 DSI 0.91 40 P1 02H

-0.14 TEH TEC 29 57 DSI 0.56 62 P1 02H 0.00 TEH TEC 30 27 DSI 1.05 85 P1 02H

-0.05 TEH TEC 30 32 DSI 0.42 124 P1 03H

-0.03 TEH TEC 30 37 DSI 0.95 52 P1 02H 0.00 TEH TEC 30 48 DSI 0.36 86 P1 02H 0.03 TEH TEC

Beaver Valley Unit #2 Page 5 of 7 2R10 S/G Examination Results 2RCS-SG21 B (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 30 50 DSI 1.21 45 P1 04H 0.14 TEH TEC 30 79 DSI 0.40 50 P1 02H 0.03 TEH TEC 30 81 DSI 0.53 89 P1 03H 0.06 TEH TEC 31 37 DSI 0.68 62 P1 03H 0.06 TEH TEC 31 39 DSI 0.74 53 P1 03H 0.11 TEH TEC 31 41 PCT 1.44 0

20 P2 AV3 0.00 TEH TEC 31 41 WAR 0.46 132 2

AV3 0.00 08C AV3 31 52 DSI 0.67 57 P1 02H 0.08 TEH TEC 31 59 PCT 1.96 0

25 P2 AV3 0.00 TEH TEC 31 59 PCT 1.18 0

18 P2 AV4 0.00 TEH TEC 31 78 DSI 0.57 63 P1 02H 0.03 TEH TEC 31 78 DSI 1.11 59 P1 03H 0.19 TEH TEC 32 29 DSI 0.39 130 P1 05H 0.08 TEH TEC 32 50 PCT 2.33 0

27 P2 AV2 0.00 TEH TEC 32 53 DSI 0.75 40 P1 02H 0.05 TEH TEC 32 55 DSI 0.84 60 P1 02H 0.03 TEH TEC 32 55 PCT 2.44 0

28 P2 AV3 0.22 TEH TEC 32 55 PCT 1.26 0

20 P2 AV4 0.40 TEH TEC 32 55 WAR 0.89 131 2

AV3 0.00 08C AV3 32 55 WAR 0.49 131 2

AV4 0.00 08C AV3 32 59 PCT 1.53 0

22 P2 AV3 0.14 TEH TEC 32 61 DSI 0.42 94 P1 02H 0.08 TEH TEC 32 62 NO!

0.64 100 3

02C 39.68 TEH TEC 32 77 DSI 0.57 81 P1 02H 0.08 TEH TEC 33 31 DSI 1.22 59 P1 03H 0.00 TEH TEC 33 32 DSI 0.63 129 P1 02H 0.03 TEH TEC 33 37 DSI 0.25 147 P1 04H 0.11 TEH TEC 33 41 PCT 2.30 0

26 P2 AV2 0.00 TEH TEC 33 41 PCT 1.41 0

20 P2 AV3 0.00 TEH TEC 33 41 WAR 0.65 110 2

AV2 0.00 08C AV2 33 41 WAR 0.39 118 2

AV3 0.00 08C AV2 33 43 PCT 1.37 0

20 P2 AV2 0.00 TEH TEC 33 57 PCT 0.75 0

14 P2 AV1

-0.40 TEH TEC 33 57 PCT 1.00 0

16 P2 AV2 0.00 TEH TEC 33 58 NOI 0.40 111 3

02C 7.85 TEH TEC 33 58 NOI 0.38 114 3

02C 10.87 TEH TEC 33 62 DSI 0.84 55 P1 02H 0.03 TEH TEC 33 63 PCT 2.96 0

31 P2 AV2

-0.40 TEH TEC 33 63 WAR 0.78 125 2

AV2 0.00 08C AV2 34 35 DSI 0.32 107 P1 03H 0.06 TEH TEC 34 37 DSI 0.32 49 P1 03H 0.06 TEH TEC 34 48 DSI 0.43 69 P1 02H 0.00 TEH TEC 34 48 DSI 0.81 58 P1 03H 0.00 TEH TEC 34 50 PCT 1.84 0

23 P2 AV1 0.00 TEH TEC 34 50 PCT 1.85 0

23 P2 AV3 0.00 TEH TEC 34 50 WAR 0.68 126 2

AV1 0.00 08C AVI 34 50 WAR 0.44 127 2

AV3 0.00 08C AV1 34 55 PCT 0.66 0

13 P2 AV1

-0.40 TEH TEC 34 55 PCT 3.09 0

31 P2 AV3 0.03 TEH TEC 34 57 PCT 1.42 0

19 P2 AV2 0.06 TEH TEC 34 57 WAR 0.47 117 2

AV2 0.20 08C AV2

Beaver Valley Unit #2 2R10 S/G Examination Results 2RCS-SG21 B (TUBES WITH INDICATIONS)

Page 6 of 7 Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 35 19 PCT 1.01 35 21 PCT 0.99 35 25 PCT 1.76 35 25 PCT 2.16 35 27 SVI 0.21 35 40 DSI 0.73 35 41 PCT 1.54 35 41 PCT 2.46 35 41 PCT 0.91 35 41 PCT 3.35 35 41 WAR 0.63 35 41 WAR 0.42 35 41 WAR 0.92 35 50 PCT 1.21 35 50 PCT 1.39 35 50 PCT 1.96 35 50 PCT 1.74 35 50 WAR 0.60 35 50 WAR 0.56 35 50 WAR 0.32 35 54 PCT 0.54 35 58 DSI 0.52 35 63 PCT 1.28 35 63 PCT 1.70 35 71 PCT 0.89 35 71 WAR 0.63 36 19 NQI 0.62 36 19 PSI 14.46 36 19 CSI 0.99 36 31 DSI 0.99 36 41 PCT 2.62 36 41 PCT 1.84 36 41 PCT 4.00 36 41 WAR 0.90 36 41 WAR 0.58 36 41 WAR 1.15 36 42 DSI 0.36 36 50 PCT 1.61 36 50 PCT 1.39 36 50 WAR 0.41 36 50 WAR 0.40 36 55 PCT 0.30 36 55 PCT 1.05 36 55 WAR 0.16 36 55 WAR 0.45 36 56 DSI 0.53 36 63 PCT 1.30 36 63 PCT 2.11 36 74 NQI 0.26 37 29 PCT 2.13 37 32 DSI 1.04 0

0 0

0 118 62 0

0 0

0 118 127 123 0

0 0

0 123 126 124 0

129 0

0 0

145 112 149 144 55 0

0 0

114 143 119 105 0

0 97 131 0

0 86 124 61 0

0 120 0

49 18 P2 AV4 0.11 16 P2 AV3 0.23 23 P2 AV2 0.00 26 P2 AV3

-0.08 6

TSC 0.32 P1 02H 0.00 21 P2 AV1 0.00 28 P2 AV2 0.00 15 P2 AV3 0.00 32 P2 AV4 0.00 2

AV2 0.00 2

AV3 0.00 2

AV4 0.00 18 P2 AV1 0.00 20 P2 AV2 0.00 24 P2 AV3 0.00 23 P2 AV4 0.00 2

AV2 0.00 2

AV3 0.00 2

AV4 0.00 13 P2 AV1 0.00 P1 02H 0.08 20 P2 AV2 0.14 23 P2 AV3 0.05 15 P2 AV4 0.00 2

AV4 0.00 3

06H 17.19 8

06H

-0.20 9

06H 0.02 P1 02H 0.03 29 P2 AV1 0.00 24 P2 AV2 0.00 34 P2 AV3 0.00 2

AV1 0.00 2

AV2 0.00 2

AV3 0.00 P1 03H 0.14 22 P2 AV1 0.06 20 P2 AV2 0.00 2

AV1 0.00 2

AV2 0.00 6

P2 AV1 0.00 17 P2 AV2 0.00 2

AV1 0.26 2

AV2 0.00 P1 02H 0.00 16 P2 AV2 0.40 26 P2 AV3

-0.25 3

05C 12.17 26 P2 AV2 0.06 P1 03H 0.23 0.20 TEH TEC TEH TEC TEH TEC TEH TEC 68 TSC TSC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 08C AV2 08C AV2 08C AV2 TEH TEC TEH TEC TEH TEC TEH TEC 08C AV2 08C AV2 08C AV2 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 08C AV4 TEH TEC TEH TEC 06H 07H TEH TEC TEH TEC TEH TEC TEH TEC 08C AV1 08C AV1 08C AV1 TEH TEC TEH TEC TEH TEC 08C AVI 08C AV1 TEH TEC TEH TEC 08C AV1 08C AV1 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 Page 7 of 7 2R10 S/G Examination Results 2RCS-SG21 B (TUBES WITH INDICATIONS)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 37 41 PCT 0.84 0

14 P2 AV2 0.00 TEH TEC 37 41 WAR 0.44 139 2

AV2 0.00 08C AV2 37 57 DSI 0.64 66 P1 02H 0.03 TEH TEC 37 57 PCT 1.18 0

19 P2 AV2

-0.25 TEH TEC 37 57 PCT 1.04 0

17 P2 AV4 0.00 TEH TEC 37 57 WAR 0.51 122 2

AV2 0.00 08C AV2 37 57 WAR 0.52 113 2

AV4 0.00 08C AV2 38 35 DSI 0.58 68 P1 02H 0.00 TEH TEC 39 31 DSI 0.33 35 P1 05H 0.03 TEH TEC 39 33 DSI 0.31 84 P1 03H 0.11 TEH TEC 39 48 PCT 1.64 0

22 P2 AV3 0.00 TEH TEC 39 70 PCT 2.87 0

30 P2 AV3 0.03 TEH TEC 40 42 DSI 0.34 152 P1 02H

-0.06 TEH TEC 41 31 DSI 0.80 69 P1 05H 0.14 TEH TEC 41 68 PCT 0.97 0

16 P2 AVI 0.00 TEH TEC 42 28 PCT 1.32 0

20 P2 AV3 0.00 TEH TEC 42 28 WAR 0.26 105 2

AV3 0.00 08C AV3 42 29 PCT 1.34 0

19 P2 AV1 0.00 TEH TEC 42 47 PCT 1.30 0

22 P2 AVI 0.00 TEH TEC 42 51 DSI 0.21 119 P1 04H 0.14 TEH TEC 42 55 PCT 1.06 0

18 P2 AV1 0.08 TEH TEC 42 55 PCT 1.27 0

20 P2 AV2

-0.11 TEH TEC 45 54 PSI 18.74 349 8

02H 0.14 TEH TEC 45 54 CSI 0.53 143 9

02H

-0.09 02H 02H

ATTACHMENT 5A BEAVER VALLEY UNIT #2 2R10 S/G EXAMINATION RESULTS 2RCS-SG21B TUBES REMOVED FROM SERVICE

Beaver Valley Unit #2 Page 1 of 1 2R10 S/G Examination Results 2RCS-SG21 B (TUBES REMOVED FROM SERVICE)

Row Col Ind Volts Phase %TW Chan Loc Inch1 Cr-Length Cr-Angle From To 2

30 PVN 1.06 30 P2 08H 5.00 08H 08C 8

41 SCI 0.52 121 P2 TSH

-0.07.

148 TSH TSH 8

42 SCI 0.21 93 P2 TSH

-0.03 78 TSH TSH 10 62 NOI 0.34 96 3

04C 24.63 TEH TEC 10 62 SVI 0.22 87 6

04C 24.51 0.27 56 04C 05C 11 3

HIGH CYCLE FATIGUE (POWER UPRATE)

TEH TEC 11 4

HIGH CYCLE FATIGUE (POWER UPRATE)

TEH TEC 19 27 SCI 0.06 82 P2 TSH

-0.03 52 TSH TSH 23 87 NQI 0.31 124 P1 01C 0.41 TEH TEC 23 87 SVI 0.34 126 6

01C 0.34 0.35 79 01C 01C 23 88 NOI 0.54 104 P1 01C 0.41 TEH TEC 23 88 SVI 0.50 82 6

01C 0.68 0.65 83 01C 01C 24 27 SAI 0.19 80 6

TSH 0.10 0.27 TSH TSH 24 73 SCI 0.11 102 P2 TSH

-0.07 89 TSH TSH 28 71 SCI 0.12 104 P2 TSH

-0.07 59 TSH TSH 35 27 SVI 0.21 118 6

TSC 0.32 0.20 68 TSC TSC

ATTACHMENT 6 BEAVER VALLEY UNIT #2 2R10 S/G EXAMINATION RESULTS 2RCS-SG21C TUBES WITH INDICATIONS

Beaver Valley Unit #2 2R1 0 S/G Examination Results 2RCS-SG21 C (TUBES WITH INDICATIONS)

Page 1 of 4 Row Col 1

25 2

45 2

64 2

64 2

66 2

78 2

83 2

85 2

91 3

18 3

18 3

39 3

43 3

58 3

60 3

60 3

64 3

64 3

64 3

64 3

70 3

70 3

70 4

48 4

48 4

49 4

50 4

76 4

76 5

5 5

10 5

19 5

42 5

44 5

45 5

62 6

23 6

54 6

55 6

63 6

78 6

92 7

40 7

49 7

49 7

67 7

80 8

15 8

21 8

23 8

63 Ind Volts Phase %TW Chan Loc Inch1 CR-Length CR-Angle From To PVN 2.16 26 P2 08H 6.75 08H 08C RBD 08C 08H DSI 0.21 27 P1 02H

-0.03 08H TEH SAI 0.18 122 6

02H 0.09 0.49 02H 02H RBD 08C 08H DSI 0.63 56 P1 03H 0.26 08H TEH RBD 08C 08H DSI 0.55 56 P1 03H

-0.06 08H TEH RBD 08C 08H DSI 0.50 96 P1 03H 0.00 08H TEH DSI 0.49 89 P1 03H 0.05 08C TEH DSI 0.45 63 P1 07H 0.00 08H TEH MAI 0.31 84 6

TSH 0.60 0.22 TSH TSH DSI 1.10 60 P1 02H 0.14 08H TEH DSI 0.54 67 P1 02H 0.06 08H TEH DSI 0.40 49 P1 03H 0.00 08H TEH DSI 0.16 94 P1 02H

-0.03 08H TEH DSI 0.42 55 P1 03H

-0.06 08H TEH DSI 0.36 114 P1 02H 0.00 08C TEH DSI 1.20 60 P1 03H 0.00 08C TEH DSI 0.28 91 P1 03H 0.00 08H TEH SAI 0.14 108 6

03H

-0.09 0.35 03H 03H DSI 0.21 77 P1 03H 0.02 08C TEH DSI 0.45 81 P1 02H

-0.04 08H TEH DSI 0.44 107 P1 02H

-0.07 08C TEH DSI 1.08 110 P1 03H 0.17 08H TEH SCI 0.15 86 P2 TSH

-0.04 90 TSH TSH DSI 0.70 54 P1 03H 0.17 08H TEH DSI 0.73 56 P1 03H 0.04 08C TEH DSI 0.40 136 P1 05H 0.03 TEH TEC NOI 0.50 117 3

07H 35.72 TEH TEC DSI 0.53 70 P1 02H 0.00 TEH TEC SAI 0.13 122 6

TSH 0.69 0.32 TSH TSH SAI 0.27 63 6

TSH 0.51 0.37 TSH TSH SAI 0.17 126 6

TSH 0.69 0.20 TSH TSH DSI 0.51 66 P1 02H 0.09 TEH TEC DSI 0.32 85 P1 02H 0.03 TEH TEC DSI 0.86 63 P1 03H 0.09 08H TEH DSI 0.34 69 P1 02H

-0.06 08H TEH DSI 0.62 84 P1 02H 0.00 TEH TEC DSI 0.73 65 P1 03H 0.05 TEH TEC DSI 0.33 44 P1 04H 0.02 TEH TEC DSI 0.31 61 P1 04H 0.06 TEH TEC DSI 0.64 93 P1 02H

-0.03 08H TEH DSI 0.46 65 P1 03H

-0.03 08H TEH DSI 0.44 30 P1 02H 0.02 TEH TEC DSI 0.35 89 P1 03H 0.00 TEH TEC DSI 1.25 49 P1 03H 0.24 TEH TEC NQI 0.36 97 3

01C 15.22 TEH TEC DSI 0.71 65 P1 02H 0.06 TEH TEC DSI 0.45 83 P1 06H

-0.10 TEH TEC

Beaver Valley Unit #2 2R10 S/G Examination Results 2RCS-SG21 C (TUBES WITH INDICATIONS)

Page 2 of 4 9

20 DSI 0.36 139 P1 04H 0.03 9

32 DSI 0.87 60 P1 02H 0.00 9

35 DSI 0.41 73 P1 02H

-0.03 9

41 DSI 0.45 96 P1 02H 0.06 9

42 DSI 0.79 114 P1 02H 0.00 9

42 HIGH CYCLE FATIGUE (POWER UPRATE) 9 43 HIGH CYCLE FATIGUE (POWER UPRATE) 9 45 DSI 0.48 83 P1 05H 0.00 9

47 DSI 0.56 81 P1 02H

-0.06 9

54 DSI 1.09 104 P1 02H

-0.17 9

59 NOI 0.44 86 3

03C 41.85 9

65 DSI 0.34 53 P1 06H 0.07 10 4

HIGH CYCLE FATIGUE (POWER UPRATE) 10 9

DSI 0.34 52 P1 03H 0.06 10 10 DSI 0.60 113 P1 02H

-0.09 10 24 DSI 0.43 83 P1 03H 0.06 10 37 DSI 0.64 84 P1 02H 0.00 10 51 DSI 2.46 35 P1 02H

-0.20 10 72 DSI 0.35 58 P1 02H 0.06 10 72 DSI 0.17 81 P1 03H 0.03 10 76 NOI 0.38 117 3

06C 26.15 11 49 DSI 0.56 52 P1 03H 0.03 11 62 DSI 0.53 27 P1 03H 0.06 11 70 DSI 0.45 52 P1 03H 0.03 11 72 DSI 0.71 55 P1 03H 0.03 12 59 DSI 0.98 44 P1 03H 0.09 12 70 DSI 0.48 80 P1 02H 0.03 12 70 DSI 0.22 75 P1 03H 0.11 12 83 DSI 0.20 62 P1 03H 0.11 13 43 DSI 0.46 98 P1 03H 0.03 13 59 DSI 0.40 36 P1 03H 0.09 13 63 DSI 0.37 39 P1 02H 0.08 13 64 DSI 0.73 61 P1 02H 0.03 13 81 NOI 0.45 108 3

01C 19.26 14 38 DSI 0.74 60 P1 02H 0.00 14 39 DSI 0.35 63 P1 05H 0.00 14 50 DSI 0.82 69 P1 02H 0.06 14 54 DSI 0.66 79 P1 02H 0.03 15 5

DSI 0.60 47 P1 04H 0.15 15 14 DSI 0.55 50 P1 03H 0.06 15 35 DSI 0.52 59 P1 03H 0.00 15 60 NOI 2.45 81 6

TSC 6.87 15 62 DSI 0.29 49 P1 02H 0.09 15 80 DSI 0.35 96 P1 03H

-0.03 15 87 DSI 0.43 108 P1 03H 0.03 16 57 DSI 0.75 47 P1 03H 0.09 16 73 DSI 0.50 65 P1 02H 0.06 17 47 DSI 1.49 54 P1 02H

-0.20 17 47 DSI 0.91 65 P1 03H 0.12 17 47 SAI 0.12 109 6

02H 0.03 0.33 17 61 DSI 0.90 62 P1 02H 0.06 17 63 DSI 0.45 80 P1 02H 0.03 TEH TEC TEH TEC 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEC TEH TEC TEH TEC TEH TEC TEH TEC 08H TEH 08H TEH TEH TEC TEH TEC TEH TEC 08H TEH TEH TEC TEH TEC TEH TEC 08H TEH TEH TEC TEH TEC TEH TEC 08H TEH TEH TEC TEH TEC TEH TEC TEH TEC 08H TEH 08H TEH TEH TEC TEH TEC TEH TEC TEH TEC 08H TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 08H TEH 08H TEH 02H 02H TEH TEC TEH TEC

Beaver Valley Unit #2 2R10 S/G Examination Results 2RCS-SG21 C (TUBES WITH INDICATIONS)

Page 3 of 4 18 48 DSI 0.84 18 87 NQI 0.40 19 35 DSI 0.72 19 38 DSI 0.84 19 48 DSI 0.82 19 57 DSI 0.69 20 85 DSI 0.22 21 18 DSI 0.96 21 62 DSI 0.62 21 88 NOI 1.48 21 88 NQI 0.65 21 88 NQI 0.35 22 24 DSI 0.29 22 28 NOI 0.19 22 28 SVI 0.14 22 61 DSI 0.40 22 87 NQI 0.33 23 28 DSI 0.45 23 37 DSI 0.87 23 39 DSI 0.76 23 39 DSI 0.74 23 42 DSI 0.62 23 42 DSI 0.72 23 69 DSI 0.35 24 41 DSI 0.66 24 48 DSI 1.29 24 50 DSI 0.67 24 61 DSI 0.76 25 34 DSI 0.64 25 47 DSI 1.06 25 54 DSI 0.53 25 65 DSI 0.67 25 79 DSI 0.47 26 39 DSI 0.75 26 42 DSI 0.85 26 70 DSI 0.73 27 20 DSI 0.70 27 60 DSI 0.98 27 76 DSI 0.67 27 82 NOI 0.82 28 42 DSI 0.43 28 44 DSI 0.52 28 73 DSI 0.83 28 85 DSI 0.18 29 37 DSI 0.49 29 47 DSI 0.65 29 63 DSI 0.67 30 38 NOI 0.48 30 41 DSI 0.42 30 60 DSI 0.98 30 61 DSI 0.97 31 49 DSI 0.46 69 58 44 48 55 41 113 84 57 85 105 108 67 97 63 65 71 86 44 76 37 71 82 14 62 68 76 88 63 37 93 50 53 43 65 77 66 79 38 119 97 99 87 89 46 83 74 107 65 69 69 56 P1 03H 0.06 3

07C 15.17 P1 03H

-0.06 P1 05H 0.03 P1 03H 0.09 P1 05H 0.09 P1 03H 0.09 P1 03H 0.21 P1 02H 0.09 3

03H 8.52 3

07C 26.19 3

07C 16.60 P1 03H 0.00 3

01H 6.65 6

01H 6.49 P1 03H 0.09 3

02C 1.70 P1 03H 0.35 P1 02H 0.00 P1 02H 0.06 P1 05H 0.06 P1 02H 0.06 P1 03H 0.00 P1 03H 0.06 P1 02H 0.06 P1 03H 0.15 P1 02H 0.06 P1 02H 0.09 P1 02H 0.12 P1 03H 0.15 P1 02H 0.03 P1 02H 0.03 P1 02H 0.06 P1 05H 0.09 P1 02H 0.06 P1 03H 0.06 P1 02H 0.00 P1 02H 0.15 P1 03H 0.06 3

02C 46.68 P1 02H 0.03 P1 02H 0.00 P1 03H 0.17 P1 02H 0.00 P1 02H 0.09 P1 02H 0.03 P1 05H 0.26 3

02H 7.36 P1 02H 0.38 P1 02H 0.00 P1 02H 0.03 P1 02H 0.09 0.36 TEH TEC TEH TEC 08H TEH 08H TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 48 01H 02H TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH %TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R1 0 S/G Examination Results 2RCS-SG21 C (TUBES WITH INDICATIONS)

Page 4 of 4 34 58 DSI 0.61 76 34 59 DSI 0.83 45 37 67 PCT 1.56 0

37 67 PCT 1.94 0

40 53 DSI 0.47 124 45 52 NOI 0.34 22 45 57 PLP 0.77 102 45 57 PLP 1.29 84 45 58 NQI 1.93 99 45 58 SVI 1.00 113 45 58 SVI 1.00 112 P1 02H 0.06 P1 02H 0.09 23 P2 AV2 0.00 26 P2 AV3 0.00 P1 04H 0.12 P1 TSH 0.66 8

01C 26.94 8

TSC 16.53 3

TSC 17.48 P2 TSC 17.59 6

TSC 17.34 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 71 TSC 02C 62 TSC 02C 0.82 0.53

ATTACHMENT 6A BEAVER VALLEY UNIT #2 2R10 S/G EXAMINATION RESULTS 2RCS-SG21C TUBES REMOVED FROM SERVICE

Beaver Valley Unit #2 2R10 S/G Examination Results 2RCS-SG21 C (TUBES REMOVED FROM SERVICE)

Page 1 of 1 Row Col 1

25 2

45 2

64 2

64 2

66 2

83 2

91 3

43 3

70 3

70 4

50 5

42 5

44 5

45 9

42 9

43 10 4

17 47 17 47 22 28 22 28 45 52 45 57 45 58 45 58 45 58 Ind Volts Phase %TW Chan Loc Inch1 CR-Length CR-Angle From To PVN 2.16 26 P2 08H 6.75 08H 08C REJECTED FOR BAD DATA (U-BEND) 08C 08H DSI 0.21 27 P1 02H

-0.03 08H TEH SAI 0.18 122 6

02H 0.09 0.49 02H 02H REJECTED FOR BAD DATA (U-BEND) 08C 08H REJECTED FOR BAD DATA (U-BEND) 08C 08H REJECTED FOR BAD DATA (U-BEND) 08C 08H MAI 0.31 84 6

TSH 0.60 0.22 TSH TSH DSI 0.28 91 P1 03H 0.00 08H TEH SAI 0.14 108 6

03H

-0.09 0.35 03H 03H SCI 0.15 86 P2 TSH

-0.04 90 TSH TSH SAI 0.13 122 6

TSH 0.69 0.32 TSH TSH SAI 0.27 63 6

TSH 0.51 0.37 TSH TSH SAI 0.17 126 6

TSH 0.69 0.20 TSH TSH HIGH CYCLE FATIGUE (POWER UPRATE) 08H TEC HIGH CYCLE FATIGUE (POWER UPRATE) 08H TEC HIGH CYCLE FATIGUE (POWER UPRATE)

TEH TEC DSI 1.49 54 P1 02H

-0.20 08H TEH SAI 0.12 109 6

02H 0.03 0.33 02H 02H NOI 0.19 97 3

01H 6.65 TEH TEC SVI 0.14 63 6

01H 6.49 0.36 48 01H 02H NOI 0.34 22 P1 TSH 0.66 TEH TEC ADMINISTRATIVELY PLUGGED (LOOSE PART)

TEH TEC NOI 1.93 99 3

TSC 17.48 TEH TEC SVI 1.00 113 P2 TSC 17.59 0.82 71 TSC 02C SVI 1.00 112 6

TSC 17.34 0.53 62 TSC 02C

ENCLOSURE 3 DEFINITIONS

ENCLOSURE 3 (Page I of 2)

Report Header Definitions Term Definition Row/Col Row & Column of tube location Ind Type of indication (See data analysis acronyms below)

Volts Voltage amplitude of an indication Phase Angular rotation of indication

%/oTW Percentage through wall of indication Chan Frequency channel from which indication was recorded Loc Location of nearest support structure Inchl Indication distance from nearest support structure lCr-Length Field measured crack length Cr-Angle Field measured crack angle From Starting point of examination To End point of examination Data Analysis (Indication) Acronym Definitions Term Bobbin Coil Definitions DNG Ding (Free-Span Region of Tube)

DNT Dent (Contained within Tube Support Plate)

DSI Distorted Support Plate Signal with Possible Indication NQI Non-Quantifiable Indication OBS Obstructed Tube PCT Percent Through Wall PSI Possible Tube Support Plate Indication PVN Permeability Variation RBD Rejected Bad Data SPR Support Plate Residual Signal Term

-Plus Point Definitions CSI Confirmed Tube Support Plate Indication DNI Dent/Ding with an Indication MAI Multiple Axial Indication MCI Multiple Circumferential Indications PTP Parent Tube Problems (Indications Behind Sleeve)

PVN Permeability Variation SAI Single Axial Indication SCI Single Circumferential Indication SSA Secondary Side Anomaly SVI Single Volumetric Indication l WAR Wear VOL Volumetric Indication

ENCLOSURE 3 (Page 2 of 2)

Examination Extent Definitions (From - To)

Term l

Definition TSH Hot Leg Tubesheet TSC Cold Leg Tubesheet O1H 1" Tube Support Plate on Hot Leg Side OiC 1" Tube Support Plate on Cold Leg Side AVB1 1't Anti-Vibration Bar (Numbered hot leg to cold leg)

STH Hot Leg Tubesheet Sleeve ISH 1" Hot Leg Tube Support Plate Sleeve 2SH 2nd Hot Leg Tube Support Plate Sleeve