Equip Cable Reel # Cable Type PO#
Insulation Material Type A308 RCA308G 15554C R34 Okoprene Compound Neoprene Thermoset A3 RCD1104A 14770-A R12 Okoprene Compound Neoprene Thermoset RCD1104B 14770-A R12 Okoprene Compound Neoprene Thermoset P36A RCA306D 15554A R34 Okoprene Compound Neoprene Thermoset 85 RCB512C 15114A R54 I Okoprene Compound Neoprene Thermoset CV2680 RCB5124F 2686 R74 Hypalon/CSPE Chlorosullonated polyethylene (CSPE)
Thermoset RCB5124G A0043 R54 CPE Chloronated polyethylene (CPE)
Thermoset CV2620 RCD1514D 2686 R74 Hypalon Chlorosulfonated polyethylene (CSPE)
Thermoset RCD1514E A0138 R54 CPE Chloronated polyethylene (CPE)
Thermoset CV2627 RCD1522D 2686 R74 Hypalon Chlorosulfonated polyethylene (CSPE)
Thermoset RCD1522E A0009 R54 CPE Chloronated polyethylene (CPE)
Thermoset CV2646 RJ1423A1 A0006 R2S CPE Chloronated polyethylene (CPE)
Thermoset CV2648 RJ1423B13 A0006 R2S CPE Chloronated polyethylene (CPE)
Thermoset CV2800 RCB5173E A0048 R74 CPE Chloronated polyethylene (CPE)
Thermoset D15 RPDO121A1 A0356 R25 Hvpalon Chlorosulfonated polyethylene (CSPE)
Thermoset RPDO121A2 A0356 R25 Hypalon Chlorosulfonated polyethylene (CSPE)
Thermoset P64A RCB5721D1 R74 RCB5721 D 5100 R74 Okoprene Compound Neoprene Thermoset P64B 880181 A0227 714 Okoprene Compound Neoprene Thermoset B801B A0227 714 Okoprene Compound Neoprene Thermoset P7A (RS2)
GCY2200A 14770-B G12 Okoprene Compound Neoprene Thermoset GCY2200B 14770-B G12 Okoprene Compound Neoprene Thermoset GCDO242AA A0529 G120 Firewall IlIl J XLPE crosslinked polyethylene Thermoset GCDO242AB A0529 G120 Firewall IlIl J XLPE crosslinked polyethylene Thermoset K4A RCA11C 15554C R34 Okoprene Compound Neoprene Thermoset RCA11D 15554C R34 Okoprene Compound Neoprene Thermoset RCE11C 15114-A R54 Okoprene Compound Neoprene Thermoset
Manuf Okonfte Okonite Okonte Okonte Okonte Anaconda Anaconda Anaconda 7 Anaconda Anaconda Anaconda Anaconda Anaconda Anaconda Anaconda Anaconda Okonite Okonte Okonte Okonfte Okonfte Rockbestos Rockbestos Okonfte Okonfte Okonfte
Equip Cable Reel # Cable Type PO##
Insulation Material Type A308 RCA308G 15554C R34 Okoprene Compound Neoprene Thermoset A3 RCD1 104A 14770-A R12 Okoprene Compound Neoprene Thermoset RCD1104B 14770-A R12 Okoprene Compound Neoprene Thermoset P36A RCA306D 15554A R34 Okoprene Compound Neoprene Thermoset 85 RCB512C 15114A R54 Okoprene Compound Neoprene Thermoset CV2680 RCB5124F 2686 R74 Hypalon/CSPE Chlorosulfonated polyethylene (CSPE)
Thermoset RCB5124G A0043 R54 CPE Chloronated polyethylene (CPE)
Thermoset CV2620 RCD1514D 2686 R74 Hypalon Chlorosulfonated polyethylene (CS PE)
Thermoset RCD1514E A0138 R54 CPE Chloronated polyethylene (CPE)
Thermoset CV2627 RCD1522D 2686 R74 Hypalon Chlorosulfonated polyethylene (CSPE)
Thermoset RCD1522E A0009 R54 CPE Chloronated polyethylene (CPE)
Thermoset CV2646 RJ1423A1 A0006 R2S CPE Chloronated polyethylene (CPE)
Thermoset CV2648 RJ1423B1 A0006 R2S CPE Chloronated polyethylene (CPE)
Thermoset CV2800 RCB5173E A0048 R74 CPE Chioronated polyethylene (CPE)
Thermoset D15 RPD0121A1 A0356 R25 Hypalon Chlorosulfonated polyethylene (CSPE)
Thermoset RPDO121A2 A0356 R25 Hypalon Chlorosulfonated polyethylene (CSPE)
Thermoset P64A RCB5721D1 R74 RCB5721D 5100 R74 Okoprene Compound Neoprene Thermoset P64B B801B1 A0227 714 Okoprene Compound Neoprene Thermoset B801B A0227 714 Okoprene Compound Neoprene Thermoset P7A (RS2)
GCY2200A 14770-B G12 Okoprene Compound Neoprene Thermoset GCY2200B 14770-B G12 Okoprene Compound Neoprene Thermoset GCDO242AA A0529 G120 Firewall Ill J XLPE crosslinked polyethylene Thermoset GCDO242AB A0529 G120 Firewall Ill J XLPE crosslinked polyethylene Thermoset K4A RCA11C 15554C R34 Okoprene Compound Neoprene Thermoset RCA1O1D 15554C R34 Okoprene Compound Neoprene Thermoset RCE11C 15114-A R54 Okoprene Compound Neoprene Thermoset
Manut Okonite Okonite Okonite Okonde Okondte Anaconda Anaconda Anaconda Anaconda Anaconda Anaconda Anaconda Anaconda Anaconda Anaconda Anaconda Okonite Okonite Okonite Okonite Okonite Rockbestos Rockbestos Okonite Okonite Okonite
Equip Cable A308 RCA308G A3 RCD1104A RCD1104B P36A RCA306D B5 RCB512C P64A RCB5721D1 RCB5721D P64B 1801B1 B801B K4A RCA11C RCA11D RCE11C CV2680 RCB5124F RCB5124G CV2620 RCD1514D RCD1514E CV2627 RCD1522D RCD1522E CV2646 RJ1423A1 CV2648 RJ1423B1 CV2800 RCB5173E D15 RPD0121A1 RPDO121A2 P7A(RS2)
GCY2200A GCY2200B GCDO242AA GCDO242AB Raceways EC1175 EC1175 EC1175 EC1258 ECI 258 EC1088 EC1175 EC1088 EC1175 EC1175 EC1175 ECI 258 EC1504 EC1504 EC1504 EC1504 EC1504 EC1504 EJ 1004 EJ1004 EC1530 EC1 589 EC1589 EC2184 EC2184 EC2212 EC2212 EC1237 ECI 190 EC190 EC1190 ECI 237 EC1 093 EC1163 EC1093 EC1165 EC1236 EC1236 EC1236 EC1236 EC1176 EC1176 EC1275 EC1257 EC1164 EC1237 EC1237 EC1237 EC2213 EC2213
Raceways Located in Zone 99-M Subjected to Fire Modeling