6 I Troy Pruett - sensitivity cases Ty P.

S a.Page From:

To:

Date:

Subject:

"WALKER, JESSICA M" <JWALK12@entergy.com>

"Troy Pruett (E-mail)" <twp~nrc.gov>

9/24/02 1:33PM Sensitivity Cases Troy - I ran the following cases for you:

Case 1: ICW and AC power set to.1 (or nominal if higher), EFW set to 0.26 (this is the value from our spreadsheet bottom number), Feed and bleed to 0.32 - this gives a CCDP of 5.4E-03 c

B Case 2: ICW and AC power set to.55, EFW set to 0.6, Feed and bleed to 0.55 - this gives a CCDP of, 5.4E-02 I will also fax the Feed and bleed spreadsheets as soon as I can walk down the hall.

Thanks Jessica M Walker ANO-1 PSA Analyst Phone numbers:

Internal: 8-759-4665 External: (501)-858-4665 Pager: (501)-498-1289 email: jwalk12@entergy.com