From:

Jon Hopkins To:

drwuokko@firstenergycorp.com Date:

2/4/04 3:00PM

Subject:

Steam generator tube surveillance

Dale, We would like to have a phone call to discuss your method for assessing cracking in the roll transition in the upper tubesheet (Question 4).

Specifically, we would like to obtain the profile of the crack in tube 2A Row 63 Tube 78. We also want you to discuss your basis for assuming that the crack in this tube grew over multiple cycles (instead of one cycle or less than a cycle). Additionally, discuss your plans for inspecting this region in the future.

Friday at 9 am would be a good time to hold call.

Jon Hopkins Sr. Project Manager NRC CC:

mkleisure@firstenergycorp.com

Mail Envelope Properties (4034DDD7.362 : 6 : 20443)

Subject:

Fwd: Steam generator tube surveillance Creation Date:

2/19/04 11:01AM From:

Jon Hopkins Created By:

JBH1@nrc.gov Recipients nrc.gov owf4_po.OWFN_DO KES (Karen Skidmore)

Post Office Route owf4_po.OWFN_DO nrc.gov Files Size Date & Time Mail MESSAGE 620 02/19/04 11:01AM Options Expiration Date:

3/10/04 Priority:

Standard Reply Requested:

No Return Notification:

None Concealed

Subject:

No Security:

Standard