February 5, 2004 Mr. Randall K. Edington Vice President-Nuclear and CNO Nebraska Public Power District P. O. Box 98 Brownville, NE 68321

SUBJECT:

COOPER NUCLEAR STATION - REQUEST FOR ADDITIONAL INFORMATION REGARDING PROPOSED LICENSE AMENDMENT REQUEST FOR LOSS-OF-COOLANT ACCIDENT (LOCA) DOSE CALCULATION METHODOLOGY AND RESOLUTION OF REMAINING LICENSE CONDITION 2.C.(6) ISSUES (TAC NO. MC1572)

Dear Mr. Edington:

By letter dated December 9, 2003, Nebraska Public Power District (NPPD or the licensee) requested the NRC staff to approve its proposed license amendment request for LOCA dose calculation methodology and resolution of remaining License Condition 2.C.(6) issues. The subject amendment request also included responses to a request for additional information (RAI) issued on October 2, 2003.

On December 23, 2003, the NRC staff held a telephone call with the licensee to pose two questions regarding the RAI response. On January 12, 2004, a telephone call was held between the licensee and NRC to answer NRC staff questions posed on December 23, 2003.

The licensee had agreed to send an advance copy of the January 12, 2004, clarifications to the Project Manager. Subsequently, NPPD management determined no letter would be sent because the questions answered were clarifications of the letter and not a response to the RAI.

The NRC staff has reviewed the information provided during the January 12, 2004, call and determined that the additional information provided is required in order to complete the review and approval of the changes. As agreed upon in a call between Michelle Honcharik and Edward McCutchen on January 30, 2004, the licensee will respond to the RAI within 30 days.

The RAI is enclosed.

Sincerely,

/RA/

Michelle C. Honcharik, Project Manager, Section 1 Project Directorate IV Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-298

Enclosure:

As stated cc w/enclosure: See next page

February 5, 2004 Mr. Randall K. Edington Vice President-Nuclear and CNO Nebraska Public Power District P. O. Box 98 Brownville, NE 68321

SUBJECT:

COOPER NUCLEAR STATION - REQUEST FOR ADDITIONAL INFORMATION REGARDING PROPOSED LICENSE AMENDMENT REQUEST FOR LOSS-OF-COOLANT ACCIDENT (LOCA) DOSE CALCULATION METHODOLOGY AND RESOLUTION OF REMAINING LICENSE CONDITION 2.C.(6) ISSUES (TAC NO. MC1572)

Dear Mr. Edington:

By letter dated December 9, 2003, Nebraska Public Power District (NPPD or the licensee) requested the NRC staff to approve its proposed license amendment request for LOCA dose calculation methodology and resolution of remaining License Condition 2.C.(6) issues. The subject amendment request also included responses to a request for additional information (RAI) issued on October 2, 2003.

On December 23, 2003, the NRC staff held a telephone call with the licensee to pose two questions regarding the RAI response. On January 12, 2004, a telephone call was held between the licensee and NRC to answer NRC staff questions posed on December 23, 2003.

The licensee had agreed to send an advance copy of the January 12, 2004, clarifications to the Project Manager. Subsequently, NPPD management determined no letter would be sent because the questions answered were clarifications of the letter and not a response to the RAI.

The NRC staff has reviewed the information provided during the January 12, 2004, call and determined that the additional information provided is required in order to complete the review and approval of the changes. As agreed upon in a call between Michelle Honcharik and Edward McCutchen on January 30, 2004, the licensee will respond to the RAI within 30 days.

The RAI is enclosed.

Sincerely,

/RA/

Michelle C. Honcharik, Project Manager, Section 1 Project Directorate IV Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-298

Enclosure:

As stated cc w/enclosure: See next page DISTRIBUTION:

PUBLIC RidsNrrPMMHoncharik RidsAcrsAcnwMailCenter PDIV-1 r/f RidsNrrLADJohnson RidsNrrDlpmDpr RidsNrrDlpmLpdiv-1 (R. Gramm)

RidsOgcRp RidsRgn4MailCenter (K. Kennedy)

ACCESSION NO: ML040410725 OFFICE PDIV-1/PM PDIV-1/LA PDIV-1/SC NAME MHoncharik DJohnson RGramm DATE 2/4/04 2/4/04 2/04/04 OFFICIAL RECORD COPY DOCUMENT NAME: C:\\ORPCheckout\\FileNET\\ML040410725.wpd

REQUEST FOR ADDITIONAL INFORMATION ISSUES RELATED TO LOCA DOSE CALCULATION METHODOLOGY AND RESOLUTION OF REMAINING LICENSE CONDITION 2.C.(6) ISSUES COOPER NUCLEAR STATION (CNS) 1.

Regarding the installation of the new boundary valves, what sort of considerations were made in the sizing calculations for the handwheel actuators? The specific concern is that the Operator will be able to close the valves without assistance under the process conditions that will exist.

2.

Regarding the decision not to include the manual valves in the IST Program, how will the functional testing be performed, and how will the testing monitor/address degrading performance?

Enclosure

December 2003 Cooper Nuclear Station cc:

Mr. William J. Fehrman President and Chief Executive Officer Nebraska Public Power District 1414 15th Street Columbus, NE 68601 Mr. Clay C. Warren Vice President - Nuclear Nebraska Public Power District P. O. Box 98 Brownville, NE 68321 Mr. John R. McPhail, General Counsel Nebraska Public Power District P. O. Box 499 Columbus, NE 68602-0499 Mr. Paul V. Fleming, Licensing and Regulatory Affairs Manager Nebraska Public Power District P.O. Box 98 Brownville, NE 68321 Mr. Michael J. Linder, Director Nebraska Department of Environmental Quality P. O. Box 98922 Lincoln, NE 68509-8922 Chairman Nemaha County Board of Commissioners Nemaha County Courthouse 1824 N Street Auburn, NE 68305 Ms. Cheryl K. Rogers, Program Manager Nebraska Health & Human Services System Division of Public Health Assurance Consumer Services Section 301 Centennial Mall, South P. O. Box 95007 Lincoln, NE 68509-5007 Mr. Ronald A. Kucera, Director of Intergovernmental Cooperation Department of Natural Resources P.O. Box 176 Jefferson City, MO 65102 Senior Resident Inspector U.S. Nuclear Regulatory Commission P. O. Box 218 Brownville, NE 68321 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 1000 Arlington, TX 76011 Jerry Uhlmann, Director State Emergency Management Agency P. O. Box 116 Jefferson City, MO 65101 Chief, Radiation and Asbestos Control Section Kansas Department of Health and Environment Bureau of Air and Radiation 1000 SW Jackson Suite 310 Topeka, KS 66612-1366 Mr. Daniel K. McGhee Bureau of Radiological Health Iowa Department of Public Health 401 SW 7th Street Suite D Des Moines, IA 50309 Mr. Scott Clardy, Director Section for Environmental Public Health P.O. Box 570 Jefferson City, MO 65102-0570