ML040330236

From kanterella
Jump to navigation Jump to search

Tech Spech Pages
ML040330236
Person / Time
Site: Hope Creek PSEG icon.png
Issue date: 01/29/2004
From:
NRC/NRR/DLPM
To:
References
TAC MB8140
Download: ML040330236 (1)


Text

ADMINISTRATIVE CONTROLS PROCEDURES AND PROGRAMS (Continued) 6.8.4 The following programs shall be established, implemented, and maintained:

a.

Primary Coolant Sources Outside Containment A program to reduce leakage from those portions of systems outside containment that could contain highly radioactive fluids during a serious transient or accident to as low as practical levels. The systems include the HPCI, CS, RHR, RCIC, Containment Hydrogen Recombiner, H2/02 analyzer, Post-Accident Sampling, Control Rod Drive Hydraulic (Scram Discharge portion) systems. The program shall include the following:

1. Preventive maintenance and periodic visual inspection requirements, and
2. A service pressure leak test for each system at refueling cycle intervals or less.
b.

In-Plant Radiation Monitoring A program which will ensure the capability to accurately determine the airborne iodine concentration in vital areas under accident conditions.

This program shall include the following:

1. Training of personnel,
2. Procedures for monitoring, and
3. Provisions for maintenance of sampling and analysis equipment.
c.

Deleted HOPE CREEK 6-16 Amendment No. 149