February 9, 2004 Mr. Christopher M. Crane, President and Chief Nuclear Officer Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555

SUBJECT:

QUAD CITIES NUCLEAR POWER STATION, UNIT 1 - SCHEDULE TO RESOLVE MISSING PIECE OF STEAM DRYER

Dear Mr. Crane:

By letter dated November 28, 2003, Exelon Generation Company (EGC) identified that a portion of the Quad Cities Nuclear Power Station, Unit 1 damaged steam dryer outer hood bank was missing. Despite extensive efforts, the missing section, which measured approximately 6 and 1/2 by 9 inches and 1/2 inch thick, could not be located. Your letter provided a lost parts analysis for the missing piece of the steam dryer and your determination that it was safe to operate Unit 1 until the next refueling outage which is currently scheduled for March 2005.

Staff from the Nuclear Regulatory Commission (NRC) discussed their comments on this lost parts analysis with your staff on December 16, 2003, and we are awaiting your response. By letter dated January 22, 2004, you stated that EGC will submit a letter to the NRC documenting our decision as to whether to continue the effort to locate and retrieve the missing dryer material by August 31, 2004.

If EGC decides not to retrieve the missing piece, the NRC staff expects to review your safety analysis describing the acceptability of operating Quad Cities Unit 1 beyond the next refueling outage. We request that the safety analysis and any associated license amendment request be submitted to NRC as early as possible to allow the NRC staff sufficient time to complete our review.

If your staff has any questions concerning this letter, I may be reached at 301-415-2863.

Sincerely,

/RA/

Lawrence W. Rossbach, Project Manager, Section 2 Project Directorate III Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-254 cc: See next page

February 9, 2004 Mr. Christopher M. Crane, President and Chief Nuclear Officer Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555

SUBJECT:

QUAD CITIES NUCLEAR POWER STATION, UNIT 1 - SCHEDULE TO RESOLVE MISSING PIECE OF STEAM DRYER

Dear Mr. Crane:

By letter dated November 28, 2003, Exelon Generation Company (EGC) identified that a portion of the Quad Cities Nuclear Power Station, Unit 1 damaged steam dryer outer hood bank was missing. Despite extensive efforts, the missing section, which measured approximately 6 and 1/2 by 9 inches and 1/2 inch thick, could not be located. Your letter provided a lost parts analysis for the missing piece of the steam dryer and your determination that it was safe to operate Unit 1 until the next refueling outage which is currently scheduled for March 2005.

Staff from the Nuclear Regulatory Commission (NRC) discussed their comments on this lost parts analysis with your staff on December 16, 2003, and we are awaiting your response. By letter dated January 22, 2004, you stated that EGC will submit a letter to the NRC documenting our decision as to whether to continue the effort to locate and retrieve the missing dryer material by August 31, 2004.

If EGC decides not to retrieve the missing piece, the NRC staff expects to review your safety analysis describing the acceptability of operating Quad Cities Unit 1 beyond the next refueling outage. We request that the safety analysis and any associated license amendment request be submitted to NRC as early as possible to allow the NRC staff sufficient time to complete our review.

If your staff has any questions concerning this letter, I may be reached at 301-415-2863.

Sincerely,

/RA/

Lawrence W. Rossbach, Project Manager, Section 2 Project Directorate III Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-254 cc: See next page DISTRIBUTION:

PUBLIC PDIII/2 r/f AMendiola PCoates LRossbach OGC ACRS MRing, RIII WRuland LMarsh BSheron LRaghavan ADAMS Accession Number: ML040280507 *see previous concurrences OFFICE PM:PD3-2 LA:PD3-2 SC:PD-3-2 PD:III D:DLPM NAME LRossbach PCoates DPickett for, AMendiola*

WRuland*

LMarsh DATE 2/5/04 2/5/04 2/4/04 2/4/04 2/6/04 OFFICIAL RECORD COPY

Quad Cities Nuclear Power Station Units 1 and 2 cc:

Site Vice President - Quad Cities Nuclear Power Station Exelon Generation Company, LLC 22710 206th Avenue N.

Cordova, IL 61242-9740 Quad Cities Nuclear Power Station Plant Manager Exelon Generation Company, LLC 22710 206th Avenue N.

Cordova, IL 61242-9740 Regulatory Assurance Manager - Quad Cities Exelon Generation Company, LLC 22710 206th Avenue N.

Cordova, IL 61242-9740 Quad Cities Resident Inspectors Office U.S. Nuclear Regulatory Commission 22712 206th Avenue N.

Cordova, IL 61242 David C. Tubbs MidAmerican Energy Company One River Center Place 106 E. Second, P.O. Box 4350 Davenport, IA 52808-4350 Vice President - Law and Regulatory Affairs MidAmerican Energy Company One River Center Place 106 E. Second Street P.O. Box 4350 Davenport, IA 52808 Chairman Rock Island County Board of Supervisors 1504 3rd Avenue Rock Island County Office Bldg.

Rock Island, IL 61201 Regional Administrator U.S. NRC, Region III 801 Warrenville Road Lisle, IL 60532-4351 Illinois Emergency Management Agency Division of Disaster Assistance &

Preparedness 110 East Adams Street Springfield, IL 62701-1109 Document Control Desk - Licensing Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Senior Vice President - Nuclear Services Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Vice President of Operations - Mid-West Boiling Water Reactor Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Vice President - Licensing and Regulatory Affairs Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Director - Licensing and Regulatory Affairs Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Associate General Counsel Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Manager Licensing - Dresden, Quad Cities and Clinton Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Quad Cities Nuclear Power Station Units 1 and 2 cc:

Manager Licensing - Dresden, Quad Cities, and Clinton Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555