December 2003 Monthly Operating Report for Wolf Creek Generating Station
ML040210488
Person / Time
Site: Wolf Creek Wolf Creek Nuclear Operating Corporation icon.png
Issue date: 01/13/2004
From: Moles K
Wolf Creek
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
GL-97-002, RA 04-0008
Download: ML040210488 (3)


Text

WNLF CREEK

'NUCLEAR OPERATING CORPORATION Kevin J. Moles Manager Regulatory Affairs JAN 132004 RA 04-0008 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555

Subject:

Docket No. 50-482: December 2003 Monthly Operating Report Gentlemen:

Attached to this letter is the December 2003, Monthly Operating Report for the Wolf Creek Generating Station.

This submittal-is being made in accordance with the requirements of Wolf Creek Generating Station Technical Specification 5.6.4, "Monthly Operating Reports."- This submittal also follows the guidance of Generic-Letter 97-02, "Revised Contents of the Monthly Operating-Report."

If you have any questions regarding this report, please contact me at (620) 364-4126, or Ms. Jennifer Yunk at (620) 364-4272.

Very t ly yoursyl Ke nKJ.

KJM/rig---

.Attachment cc:

J. N. Donohew (NRC), w/a D. N. Graves (NRC), w/a

--B.

S.- Mallett (NRC), w/a Senior Resident Inspector (NRC), w/a 1_X OZA P.O. Box 411 / Burlington, KS 66839/ Phone: (620) 364-8831

- An Equal Opportunity Employer MIF/HC/VET

Attachment to RA 04-0008 Page 1 of 2 OPERATING DATA REPORT Report Number: 226 DOCKET NO.:

UNIT NAME:

DATE:

COMPLETED BY:

TELEPHONE:

50-482 Wolf Creek Generating Station January 15, 2004 J. L. Yunk (620) 364-4272 REPORT MONTH: December 2003 I 1. I Design Electrical Rating (MWe - Net):

l 1170

12.

lMaximum Dependable Capacity (MWe - Net):

1167 This Month Year to Date Cumulative

3.

Number of Hours Reactor Critical:

737.10 7,640.87 137,776.67

4.

Number of Hours Generator On-Line:

705.35 7,596.05 136,541.85

5.

Unit Reserve Shutdown Hours:

0.00 0.00 339.80

6.

Net Electrical Energy Generated (MWH) 807,951.00 8,889,667.00 154,968,371.00 Wolf Creek Generating Station Monthly Operating Report December 2003 Page 1 of 2

I, Attachment to RA 04-0008 Page 2 of 2 UNIT SHUTDOWN AND POWER REDUCTIONS DOCKET NO.:

UNIT NAME:

DATE:

COMPLETED BY:

TELEPHONE:

50-482 Wolf Creek Generating Station January 15, 2004 J. L. Yunk (620) 364-4272 Type METHOD OF SHUTTING F: FORCED DURATION REASON DOWN THE REACTOR CORRECTIVE ACTIONS/COMMENTS No.

Date S: SCHEDULED (Hours)

(1)

(2) 03-03 10/18/2003 S

36.93 C

4 Refueling Outage XIII extended on -.

__November 22, 2003 @ 0600 03-04 12102/2003 S

1.72 C

5 Turbine Overspeed Test

SUMMARY

Refuel XIII began on 10/18/2003 at 0000 and was completed 12/02/2003 at 1256.

(1) REASON:

A: EQUIPMENT FAILURE (EXPLAIN)

B: MAINTENANCE OR TEST C: REFUELING D: REGULATORY RESTRICTION E: OPERATOR TRAINING AND LICENSE EXAMINATION F: ADMINISTRATIVE G: OPERATIONAL ERROR (EXPLAIN)

H: OTHER (EXPLAIN)

(2) METHOD: 1. MANUAL

2. MANUAL SCRAM
3. AUTOMATIC SCRAM
4. CONTINUATION
5. OTHER Wolf Creek Generating Station Monthly Operating Report December 2003 Page 2 of 2