Thomas Alexion - Nozzle 83/84 PT Report Page 1 From:
"BENNETT, STEVE A <SBENNE2@entergycom>
To:
Tom Alexion <twa6Dnrc.gov>
Date:
10/7/03 9:59AM
Subject:
Nozzle 83/84 PT Report
- Tom, Attached is the PT Report that was provided to the NRC Inspector here on the PT Information for ANO-2 ICI Nozzles 83 & 84. This should help Terence's group better understand where the indications were located.
Steve Bennett NSA - Licensing 479-858-4626 Pager: 479-890-3323
I C.WIND0WS\\TEMP\\GWI00001.TMP Page 1 I C:\\WINDOWS\\TEMP\\GWIOQOO1.TMP Paqe 1 I Mail Envelope Properties (3F82C6CA.9E0:13: 55776)
Subject:
Creation Date:
From:
Nozzle 83/84 PT Report 10/7/03 9:57AM "BENNETT, STEVE A" <SBENNE2@entergv.com>
Created By:
SBENNE2 @entcrzv.com Recipients nrc.gov owf4_po.OWFN_DO TWA (Thomas Alexion)
Post Office owf4,.po.OWFNDO Route nrc.gov Files Size MESSAGE 285 Part.001 1002 ANO2 Nozzle 83&84 PT Exams.pdf Mime.822 2037643 Date & Time 10/07/03 09:57AM 1486826 Options Expiration Date:
Priority:
Reply Requested:
Return Notification:
Concealed
Subject:
Security:
None Standard No None No Standard
NDE REPORT NO ANO LIQUID PENETRANT 1-9 2031SIPTOOS e
NDE EXAMINATION 0 PSI 0 MAINTENANCE 203151PT005 0 INFO 0 WQT0 UNIT #1 UNIT 92 OUTAGE JOB ORDER NO OTHER TRACE DOCUMENTS DATE 2R16 IN/A lER-ANO-2003-0245-003 9/2812003 SYSTEII I INE NO l
ISO/DWG; NO l
COMPONENT DESCR IPTION RPV
~~N/A l
E 234-76 RPV ICI NOZZLE CODE SECTION EDITION CODE SUBSECTION EXAM CATEGORY PROCEDUREIREV ASME SECTION Xl 92 N/A NM NDE 9.41 1
1 MATERIAL TYPE SURFACE CONDITION ZERO REFERENCE O CS SS 13 INCONEL BUFFED LOW HILL CIL TECHNIQUE METHOD UV METER
@) SOLVENT REMOVABLE (3 VISIBLE MODEL NO NIA O WATER WASHABLE 0
FLOURESC ENT SIN:
N/A TEMP EXAM SURFACE TEMP MATERIALS THERMOMETER 80 800 SIN 214516 EXP DATE 2/2712004 PENETRANT CLEANER DEVELOPER BRAND#
BATCH#
TIME BRAND#
BATCH#
BRAND#
BATCH#
TIME SKL-SP lOH04K 20 min SKC-S I
02801K SKD-S2 01A01K 7
min PART IDENTIFICATION RESULTS CODE REMARKS RPV ICI NOZZLE 82 ACC NI RPV ICI-NOZZLE 83 REJ Linear SEE ATTACHED SKETCH.
RPV IC NOZZLE 84 REJ Linear SEE ATTACHED SKETCH.
RPV ICI NOZZLE 85 ACC NI RPV ICI NOZZLE 86 ACC NI RPV ICI NOZZLE 87 ACC NI RPV ICI NOZZLE 88 ACC Ni RP VI tC M
ZLt 8
4CCt
,Jt 4?t COMMENTS:
Indicate size, location. orientation, and distribution of indications. Provide dimensions on all sketches, use additional sheets If required.
EXAMINATION PERFORMED IN UNIT 2 REACTOR BUILDING. UNDER THE RPV HEAD ON THE HEADSTAND.
EXAMINATIONS PERFORMED TO MEET REQUIREMENTS OF NRC ORDER EA-03-009. REQUIRED EXAMINATION VOLUME WAS OBTAINED PER DIRECTIONS IN ER. EXAMINATION ASSISTED BY WADE SELBY U111, MIKE BRILEY LIlI, RUDY MEDINA 1111, STEVE CLERC Ull, MARIO CASTRO 111.
,EXAMINED BY I LEVEI ASSISTED BY I LEVEL RE RIEWED BY
)
- i ~ t L ~ ( (.
7_
f,
- RONALD VSWAIN I
II I
DATE 9/28/2003 DATE DATE 21&/03 ANII REVIEW DATE _
ENCLOSURE ADDED
( YES 0
NO PAGE
/
OF A.
t.
A.
I-r 0
, -~p-J
'd-.-
l~
'tl-4,.
em -
v, P
M, p,
f/2f/o Ic #
C MAP LEGEND J-Weld Outside ICI Stub -
Cut End of ICI Stub Blend Radius form IC1 Stub End to ID 135
.Vkbs,
a, 3 (e-t.'W Sc atXm LCA 45 AS.¢!LX~f.
¢ O
z~~~~~."
It.
o/~~~~~~~~~~~~~~~~~
CEL n
-TAlb. tf
- ~It i;A t. AP
-Low Hill Side Looking Up
gL1 IcI #
,2 3 1-5 P7
°rOcy-0Ot'pl
-o e A/1' 3
'~~1~~1/C7)
MAP LEGEND I-Weld Dutside IC] Stub -
Tut End of ICI Stub 3lend Radius form
- CI Stub End to ID VT,o}
I jtcI
- 35.
I fimil%135
-U ItC4 /'s c~prtI e4 KP4A%
it I t
'vfj,' eo':U" 0
Low Hill Side Looking Up
7/2 /o go A
PT r St
-4,3,4
7t
/I& *3.
As) lZ5/ p0roo s: f 04 rp"
-4-
m
I NDE REPORT NO ANO LIQUID PENETRANT l
ISI 2031SPTOOG EXAMINATION 0 PSI 0 MAINTENANCE20S1T6 NDE 0 INFO 0 WQT 0 UNIT#1
(
UNIT#2 OUTAGE JOB ORDER NO OTHER TRACE DOCUMENTS DATE 2R16 I
NMA ER-ANO-2003-0245-003 and -005 913012003 SYSTEM l
LINE NO ISO1DWG NO COMPONENT DESCRIPTION RPV l
IA NIA RPV ICI NOZZLES CODE SECTION EDITION CODE SUBSECTION EXAM CATEGORY PROCEDURE/REV ASME SECTION Xi 1992 NIA NIA NDE 9.41 I
1 MATERIAL TYPE SURFACE CONDITION ZERO REFERENCE o CS 0 SS
(
INCONEL GROUND LOW HILL CIL TECHNIQUE METHOD UV METER
(
SOLVENT REMOVABLE G) VISIBLE MODEL NO N/A o WATER WASHABLE 0
FLOURESCENT SIN:
NIA TEMP EXAM SURFACE TEMP MATERIALS THERMOMETER 80l 80 SIN 214516 EXP DATE 2/27/2004 PENETRANT CLEANER DEVELOPER BRAND#
BATCH#
TIME BRAND#
BATCH#
BRAND#
BATCH#
TIME SKL-SP 00H04K 20 min SKC-S I
02BO1K SKD-S2 I 01A01K l 7
min PART IDENTIFICATION RESULTS IND.
REMARKS RPV ICI Nozzle 84 ACC NRI AFTER GRINDING TO REMOVE INDICATIONS. REF:
REPORT 2031SIPT005 ACCpl'#.jCe te,?CA-,
o &
______I'v ICow}.
Ad
,za d t
'°/ffi/43~Lr'L,~
COMMENTS:
Indicate size, location, oientation, and distribution of indications. Provide dimensions on all sketches, use additional sheets if required.
EXAMINATION PERFORMED IN UNIT 2 REACTOR BUILDING, UNDER THE RPV HEAD ON THE HEADSTAND.
EXAMINATIONS PERFORMED TO MEET REQUIREMENTS OF NRC ORDER EA-03-009. EXAMINATION VOLUME WAS LIMITED TO THE AREA OF INDICATION REMOVAL. EXAMINATION ASSISTED BY MIKE BRILEY, LEVEL III AND RONNIE SWAIN, LEVEL II.
I ENCLOSURE ADDED 0
YES ANII REVIEW DATE PAGE 1
OF
(
NO
NDE REPORT NO Aft ANO LIQUID PENETRANT IS 2031SIPT007
^
NDE REXAMINATION 0 PSI.0 MAINTENANCE N D E
~~0 INFOO0 WQT 0 UN1T#1
- 0) UNIT$2 OUTAGE JOB ORDER NO OTHER TRACE DOCUMENTS DATE 2R16 l
NIA ER-ANO-2003-0245-003 and -005 913012003 SYSTEM LINE NO ISOIDWG NO COMPONENT DESCRIPTION RPV NIA N/A I RPV ICI NOZZLES CODE SECTION EDITION CODE SUBSECTION EXAM CATEGORY PROCEDUREIREV ASME SECTION X 1992 NIA NIA NDE.41 i
I MATERIAL TYPE SURFACE CONDITION ZERO REFERENCE o
CS SS (0 INCONEL GROUND LOW HILL CIL TECHNIQUE METHOD UV METER
(
SOLVENT REMOVABLE 0
VISIBLE MODEL NO NIA o
WATER WASHABLE 0
FLOURESCENT SIN:
NIA TEMP EXAM SURFACE TEMP MATERIALS THERMOMETER 80, Sol SIN 214516 EXP DATE 2/27/2004 PENETRANT CLEANER DEVELOPER BRAND#
i ATCH#
TIME BRAND#
BATCH#
BRAND#
BATCH#i TIME SKL-SP 0H04K 20 min SKC-S I
02B01K SKD-S2 01A01K 7
min PART IDENTIFICATION RESULTS IND.
REMARKS RPV ICI Nozzle 83 REJ Linear AFTER GRINDING, IDENTIFIED MULTIPLE INDICATIONS ON THE FACE END OF THE NOZZLE STUB PIECE FROM APPROXIMATELY 350 TO 30 WITH MAXIMUM DIMENSIONS OF 25'.
COMMENTS:
Indicate sze, location, orientation, and distribution of Indications. Provide dimensions on all sketches, use additional sheets if required.
EXAMINATION PERFORMED IN UNIT 2 REACTOR BUILDING, UNDER THE RPV HEAD ON THE HEADSTAND.
EXAMINATIONS PERFORMED TO MEET REQUIREMENTS OF NRC ORDER EA-03-009. EXAMINATION VOLUME WAS LIMITED TO THE AREA OF INDICATION REMOVAL.
M-IXAMA1,NI Y I LEVEL l
ASSISTED BY I LEVEL REVIEOED B RUDY MEDINA I
II NIA I
I DATE 930/2003 DATE DATE ID/A4/o 3 ANII REVIEW DATE ENCLOSURE ADDED 0
YES
(
NO PAGE 1
OF I
as Li A-I %_1 iruj%,
wws k-UNII 1
W UNII Z OUTAGE JOB ORDER NO OTHER TRACE DOCUMENTS DATE 21316 NIA ER-ANO-2003-0245-003 and -005 01212003 SYSTEM LINE NO-ISOIDWG NO COMPONENT DESCRIPTION RPV NIA NIA RPV ICI NOZZLE CODE SECTION EDITION C
CODE SUBSECTION EXAM CATEGORY PROCEDURE/REV ASME SECTION XI 1992 N/A NIANDE9.41 1
MATERIAL TYPE SURFACE CONDITION ZERO REFERENCE o
(
INCONEL BUFFED LOW HILL CIL TECHNIQUE METHOD UV METER
(
SOLVENT REMOVABLE
(
VISIBLE MODEL NO N/A o
WATER WASHABLE 0
FLOURESCENT SIN:
N/A TEMP EXAM SURFACE I TEMP MATERIALS THERMOMETER 80° 80° S/N 214516 EXP DATE 2127/2004 PENETRANT CLEANER DEVELOPER BRAND#
BATCH#
l TIME BRAND#
BATCH#
BRAND#
BATCH#
TIME SKL-SP l
00H04K 20 mn SKC-S I
02B01K SKD-S2 I 01A01K 7
min PART IDENTIFICATION RESULTS IND.
REMARKS RPV ICI Nozzle 83 REJ Rounded LOCALIZED AREA EXAMINED AFTER FLAW REMOVAL BY BUFFING. PROCESS BEGAN TO REMOVE THREE ROUNDED INDICATIONS FROM THE PREVIOUS EXAMINATION. AFTER THREE PROCESSES OF SURFACE CONDITIONING AND PT EXAMINATIONS, THE AREA CONTAINED ONE REMAINING ROUNDED INDICATION AT THE RIGHT SIDE OF THE EXCAVATION ADJACENT TO THE FUSION ZONE OF THE NOZZLE TO THE FILLET WELD.
COMMENTS:
Indicate size, location, orientation, and distribution of indications. Provide dimensions on all skelches, use additional sheets if required.
EXAMINATION PERFORMED IN UNIT 2 REACTOR BUILDING, UNDER THE RPV HEAD ON THE HEADSTAND.
EXAMINATIONS PERFORMED TO MEET REQUIREMENTS OF NRC ORDER EA.03-009. THE EXAMINATION VOLUME WAS LIMITED TO THE AREA OF FLAW REMOVAL ONLY. EXAMINATION ASSISTED BY WADE SELBY LuII, VIA REMOTE HEADSET.
EXAMINED
/511 LEVEL ASSISTED BY I LEVEL REVIEDBY WILLIAM A. RAYtjR I
II I
DATE 9128/2003 DATE DATE A /3 ANII RFVIFW DATF ENCLOSURE ADDED (i
YES 0
NO PAGE 1
OF 3
4 A N\\
Jobs rJ 10 2-7L4-2j--q
LU -
} U INl-U Wl
(
UNIT #1 i)
UNIT #2 OUTAGE JOB ORDER NO OTHER TRACE DOCUMENTS DATE 2R16 N/A ER-ANO-2003-0245-003 and -005 1012/2003 SYSTEM LINE NO ISO)DWG NO COMPONENT DESCRIPTION RPV N/A N/A I RPV ICI NOZZLE CODE SECTION EDITION CODESUBSECTION EXAM CATEGORY PROCEDURE/REV ASME SECTION Xi 1992 N/A NIA NDE 9.41 MATERIAL TYPE SURFACE CONDITION.
ZERO REFERENCE o CS 0 SS INCONEL BUFFED LOW HILL C/L TECHNIQUE METHOD UV METER i
SOLVENT REMOVABLE G) VISIBLE MODEL NO N/A o
WATER WASHABLE 0
FLOURESCENT S/N:
NIA TEMP EXAM SURFACE I TEMP MATERIALS THERMOMETER 800 800 SIN 214516 EXP DATE 2/2712004 PENETRANT CLEANER DEVELOPER BRAND#
ATCH#
TIME BRAND#
BATCH#
BRAND#
BATCH#
TIME SKL-SP OOH04K 20 mn SKC-S 02BO1K SKD-S2 01A01K 7
min PART IDENTIFICATION RESULTS CODE REMARKS RPV ICI Nozzle 83 REJ Rounded PT OF THE EXCAVATED AREA REVEALED 3 INDICATIONS MEASURING APPROX. 118"x1i/16" EA.
THESE INDICATIONS WERE CATAGORIZED AS SLAG INCLUSION BY VISUAL EXAMINATION.
COMMENTS:
Indicate size, location, orientation, and distribution of ndications. Provide dimensions on all sketches, use additional sheets 1 required.
EXAMINATION PERFORMED IN UNIT 2 REACTOR BUILDING, UNDER THE RPV HEAD ON THE HEADSTAND.
EXAMINATIONS PERFORMED TO MEET REQUIREMENTS OF NRC ORDER EA-03-009. THE EXAMINATION VOLUME WAS THE AREA OF FLAW REMOVAL ONLY.
A EXAMINED BY I LEVEL e-'e RAY STRICKLAND DATE 10/212003 I
I ANIIRFVIFW DATE ENCLOSURE ADDED (3 YES NO PAGE 1
OF 1
ENCLOSURE ADDED YES Owo PAGE 1
OF I
I Xy NDE tARMIINmA I Iviv O
INFO 0 WQT lo UNIT#1 G UNIT#2 OTHER TRACE DOCUMENTS ER-ANO-2003-0245-003 and -005 DATE 10/2/2003 COMPONENT DESCRIPTION I RPV ICI NOZZLE I
CODE SUBSECTIONI EXAM CATEGORY N/A N/A PROCEDUREIREV I
NDE 9.41 I
I SURFACE CONDITION BUFFED ZERO REFERENCE LOW HILL CL TECHNIQUE METHOD UV METER SOLVENT REMOVABLE i
VISIBLE MODEL NO N/A i 0 WATER WASHABLE 0
FLOURESCENT SIN:
N/A TEMP EXAM SURFACE TEMP MATERIALS THERMOMETER 80 800 SIN 214516 EXP DATE 2127/2004 PENETRANT CLEANER DEVELOPER BRAND#
l BATCH#
l TIME BRAND#
BATCH#
BRAND#
BATCH#
TIME SKL-SP l 00H04K I 20 mn SKC-S 02BOIK SKD-S2 01AOIK 7
min PART IDENTIFICATION RESULTS CODE REMARKS RPV ICI Nozzle 83 ACC NI THE FINAL PT EXAMINATION OF THE EXCAVATED AREA. NO INDICATIONS REVEALED.
oAS<<
7Ac-c al7-24, St6I COMMENTS:
Indicate size. location, orientation, and distribution of nd-iatit.
.pvi de d imensions on all sketches, use additional sheets If required.
EXAMINATION PERFORMED IN UNIT 2 REACTOR BUILDING. UNDER THE RPV HEAD ON THE HEADSTAND.
EXAMINATIONS PERFORMED TO MEET REQUIREMENTS OF NRC ORDER EA-03-009. THE EXAMINATION VOLUME WAS THE AREA OF FLAW REMOVAL ONLY.
I I
DATF 101212003 I
DATE ANII RFVIFW.
DAT..___
PAGE 1
OF ENCLOSURE ADDED YES 0
NO