December 2, 2003 Mr. C. Lance Terry Senior Vice President
& Principal Nuclear Officer TXU Energy ATTN: Regulatory Affairs P. O. Box 1002 Glen Rose, TX 76043
SUBJECT:
RESPONSE TO ORDER FOR COMPENSATORY MEASURES RELATED TO ACCESS AUTHORIZATION
Dear Mr. Terry:
On January 7, 2003, the U.S. Nuclear Regulatory Commission (NRC or Commission) issued Orders to holders of licenses for operating nuclear power reactors, for the implementation of compensatory measures (CMs) related to access authorization. On January 27, 2003, TXU Generating Company LP, licensee for the Comanche Peak Steam Electric Station, submitted its written response to the Order.
The NRC staff has completed its review of your response. Based on that review, the NRC staff finds that your response to the January 7, 2003, Order is acceptable and responsive to the Order.
Please remember, pursuant to Section III.C.2 of the Order, you are to report to the Commission, in accordance with Title 10 of the Code of Federal Regulations, Section 50.4, when you have achieved full compliance with the requirements described in Attachment 2 to the Order. The NRC will determine the effectiveness of your implementation of the CMs through onsite inspections.
If you have any questions about this letter, please call Mr. Christopher Gratton at 301-415-1055.
Sincerely,
/RA/
Richard J. Laufer, Chief, Section 1 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-445 and 50-446 cc: See next page
December 2, 2003 Mr. C. Lance Terry Senior Vice President
& Principal Nuclear Officer TXU Energy ATTN: Regulatory Affairs P. O. Box 1002 Glen Rose, TX 76043
SUBJECT:
RESPONSE TO ORDER FOR COMPENSATORY MEASURES RELATED TO ACCESS AUTHORIZATION
Dear Mr. Terry:
On January 7, 2003, the U.S. Nuclear Regulatory Commission (NRC or Commission) issued Orders to holders of licenses for operating nuclear power reactors, for the implementation of compensatory measures (CMs) related to access authorization. On January 27, 2003, TXU Generating Company LP, licensee for the Comanche Peak Steam Electric Station, submitted its written response to the Order.
The NRC staff has completed its review of your response. Based on that review, the NRC staff finds that your response to the January 7, 2003, Order is acceptable and responsive to the Order.
Please remember, pursuant to Section III.C.2 of the Order, you are to report to the Commission, in accordance with Title 10 of the Code of Federal Regulations, Section 50.4, when you have achieved full compliance with the requirements described in Attachment 2 to the Order. The NRC will determine the effectiveness of your implementation of the CMs through onsite inspections.
If you have any questions about this letter, please call Mr. Christopher Gratton at 301-415-1055.
Sincerely,
/RA/
Richard J. Laufer, Chief, Section 1 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-445 and 50-446 cc: See next page DISTRIBUTION:
PUBLIC C. Gratton R. Laufer T. Marsh E. Leeds H. Berkow D. Johnson C. Raynor R. Gramm J. Shea M. Burrell C. Nolan W. Johnson, RIV M. Thadani OGC ACRS M. Fields, EDO PDIV-1 r/f Adams Accession No.: ML033360622 OFFICE PDII-2/PM PDI-2/LA PDIV-1/LA NSIR PDI-1/SC NAME CGratton CRaynor MMcAllister C Nolan RLaufer DATE 10/24/2003 10/24/2003 11/6/2003 11/28/2003 12/2/2003 OFFICIAL RECORD COPY
March 2003 Comanche Peak Steam Electric Station cc:
Senior Resident Inspector U.S. Nuclear Regulatory Commission P. O. Box 2159 Glen Rose, TX 76403-2159 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011 Mr. Roger D. Walker Regulatory Affairs Manager TXU Generation Company LP P. O. Box 1002 Glen Rose, TX 76043 George L. Edgar, Esq.
Morgan Lewis 1111 Pennsylvania Avenue, NW Washington, DC 20004 County Judge P. O. Box 851 Glen Rose, TX 76043 Environmental and Natural Resources Policy Director Office of the Governor P. O. Box 12428 Austin, TX 78711-3189 Mr. Richard A. Ratliff, Chief Bureau of Radiation Control Texas Department of Health 1100 West 49th Street Austin, TX 78756-3189 Mr. Brian Almon Public Utility Commission William B. Travis Building P. O. Box 13326 1701 North Congress Avenue Austin, TX 78701-3326 Ms. Susan M. Jablonski Office of Permitting, Remediation and Registration Texas Commission on Environmental Quality MC-122 P. O. Box 13087 Austin, TX 78711-3087 Terry Parks, Chief Inspector Texas Department of Licensing and Regulation Boiler Program P. O. Box 12157 Austin, TX 78711 Neil Harris Comanche Peak Steam Electric Station, Units 1 & 2 TXU Generation Company LP FM 56 5 Miles North of Glen Rose Glen Rose, TX 76043