November 26, 2003 Mr. Bryce L. Shriver Senior Vice President and Chief Nuclear Officer PPL Susquehanna, LLC 769 Salem Boulevard, NUCSB3 Berwick, PA 18603-0467

SUBJECT:

SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2 - CHANGES TO TECHNICAL SPECIFICATIONS BASES PAGES (TAC NOS. MB6748 AND MB6749)

Dear Mr. Shriver:

In a letter dated November 8, 2002, PPL Susquehanna (PPL, the licensee), provided to the U.S. Nuclear Regulatory Commission (NRC) proposed Technical Specification (TS) Bases changes to resolve concerns related to the Susquehanna Steam Electric Station, Units 1 and 2 (SSES 1 and 2), TS limiting condition for operation 3.1.7, Standby Liquid Control (SLC)

System. These concerns, documented as unresolved item 2001-004-03, were discussed in a memorandum to NRC, Region I, (A. Randolph Blough, Director, Division of Reactor Projects, Task Interface Agreement 2001-12) dated May 6, 2002. The NRC staff concluded that PPL must consider the anticipated transient without scram (ATWS) rule functional requirements as part of the SLC system design bases and must consider the ATWS rule functional requirements for assessing SLC system operability.

As discussed in a telecon with your staff on April 22, 2003, the proposed bases change will not resolve the concerns. We understand that you will resolve these concerns through your Problem Identification and Resolution (PI&R) Program and by coordinating with the NRC, Region I, PI&R Inspection Team.

If you have any questions regarding this matter, I may be reached at 301-415-1030.

Sincerely,

/RA/

Richard V. Guzman, Project Manager, Section 1 Project Directorate I Division of Licensing Pro+ject Management Office of Nuclear Reactor Regulation Docket Nos. 50-387 and 50-388 cc: See next page

November 26, 2003 Mr. Bryce L. Shriver Senior Vice President and Chief Nuclear Officer PPL Susquehanna, LLC 769 Salem Boulevard, NUCSB3 Berwick, PA 18603-0467

SUBJECT:

SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2 - CHANGES TO TECHNICAL SPECIFICATIONS BASES PAGES (TAC NOS. MB6748 AND MB6749)

Dear Mr. Shriver:

In a letter dated November 8, 2002, PPL Susquehanna (PPL, the licensee), provided to the U.S. Nuclear Regulatory Commission (NRC) proposed Technical Specification (TS) Bases changes to resolve concerns related to the Susquehanna Steam Electric Station, Units 1 and 2 (SSES 1 and 2), TS limiting condition for operation 3.1.7, Standby Liquid Control (SLC)

System. These concerns, documented as unresolved item 2001-004-03, were discussed in a memorandum to NRC, Region I, (A. Randolph Blough, Director, Division of Reactor Projects, Task Interface Agreement 2001-12) dated May 6, 2002. The NRC staff concluded that PPL must consider the anticipated transient without scram (ATWS) rule functional requirements as part of the SLC system design bases and must consider the ATWS rule functional requirements for assessing SLC system operability.

As discussed in a telecon with your staff on April 22, 2003, the proposed bases change will not resolve the concerns. We understand that you will resolve these concerns through your Problem Identification and Resolution (PI&R) Program and by coordinating with the NRC, Region I, PI&R Inspection Team.

If you have any questions regarding this matter, I may be reached at 301-415-1030.

Sincerely,

/RA/

Richard V. Guzman, Project Manager, Section 1 Project Directorate I Division of Licensing Pro+ject Management Office of Nuclear Reactor Regulation Docket Nos. 50-387 and 50-388 cc: See next page DISTRIBUTION:

PUBLIC PDI-1 RF RLaufer RGuzman ACRS TBlount MOBrien OGC CBixler, RGN-1 ADella Greca ACCESSION NO.: ML033300381 OFFICE PDI-1/PM PDI-I/LA PDI-1/SC NAME RGuzman MOBrien RLaufer DATE 11/25/03 11/25/03 11/25/03 OFFICIAL RECORD COPY

Susquehanna Steam Electric Station, Units 1 & 2 cc:

Bryce L. Shriver Senior Vice President and Chief Nuclear Officer PPL Susquehanna, LLC 769 Salem Blvd., NUCSB3 Berwick, PA 18603-0467 Richard L. Anderson Vice President - Nuclear Operations PPL Susquehanna, LLC 769 Salem Blvd., NUCSB3 Berwick, PA 18603-0467 Aloysius J. Wrape, III General Manager - Nuclear Assurance PPL Susquehanna, LLC Two North Ninth Street, GENA92 Allentown, PA 18101-1179 Terry L. Harpster General Manager - Plant Support PPL Susquehanna, LLC 769 Salem Blvd., NUCSA4 Berwick, PA 18603-0467 Robert A. Saccone General Manager - Nuclear Engineering PPL Susquehanna, LLC 769 Salem Blvd., NUCSB3 Berwick, PA 18603-0467 Rocco R. Sgarro Manager - Nuclear Regulatory Affairs PPL Susquehanna, LLC Two North Ninth Street, GENA61 Allentown, PA 18101-1179 Curtis D. Markley Supervisor - Nuclear Regulatory Affairs PPL Susquehanna, LLC 769 Salem Blvd., NUCSA4 Berwick, PA 18603-0467 Michael H. Crowthers Supervising Engineer Nuclear Regulatory Affairs PPL Susquehanna, LLC Two North Ninth Street, GENA61 Allentown, PA 18101-1179 Dale F. Roth Manager - Quality Assurance PPL Susquehanna, LLC 769 Salem Blvd., NUCSB2 Berwick, PA 18603-0467 Herbert D. Woodeshick Special Office of the President PPL Susquehanna, LLC 634 Salem Blvd., SSO Berwick, PA 18603-0467 Bryan A. Snapp, Esq Assoc. General Counsel PPL Services Corporation Two North Ninth Street, GENTW3 Allentown, PA 18101-1179 Supervisor - Document Control Services PPL Susquehanna, LLC Two North Ninth Street, GENTW3 Allentown, PA 18101-1179 Richard W. Osborne Allegheny Electric Cooperative, Inc.

212 Locust Street P.O. Box 1266 Harrisburg, PA 17108-1266 Director - Bureau of Radiation Protection Pennsylvania Department of Environmental Protection P.O. Box 8469 Harrisburg, PA 17105-8469

Susquehanna Steam Electric Station, Units 1 & 2 cc:

Susquehanna Steam Electric Station, Units 1 & 2 cc:

Senior Resident Inspector U.S. Nuclear Regulatory Commission P.O. Box 35, NUCSA4 Berwick, PA 18603-0035 Regional Administrator, Region 1 U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Board of Supervisors Salem Township P.O. Box 405 Berwick, PA 18603-0035 Dr. Judith Johnsrud National Energy Committee Sierra Club 443 Orlando Avenue State College, PA 16803