ML033110537
| ML033110537 | |
| Person / Time | |
|---|---|
| Site: | Susquehanna |
| Issue date: | 10/31/2003 |
| From: | Susquehanna |
| To: | Office of Nuclear Reactor Regulation |
| References | |
| 28401 EP-PS-114, Rev 10 | |
| Download: ML033110537 (4) | |
Text
Oct. 31, 2003 Page 1 of 1 MANUAL HARD COPY DISTRIBUTION DOCUMENT TRANSMITTAL 2003-51637 USER INFORMATION:
Name:G H*RO M
Address: NUK Phone#: 2 319 TRANSMITTAL INFORMATION:
EMPL#:28401 CA#:0363 TO:
10/31/2003 LOCATION:
DOCUMENT CONTROL DESK FROM:
NUCLEAR RECORDS DOCUMENT CONTROL CENTER (NUCSA-2)
THE FOLLOWING CHANGES HAVE OCCURRED TO THE HARDCOPY OR ELECTRONIC.MANUAL ASSIGNED TO YOU:
114 -
114 -
CHEMISTRY COORDINATOR:
EMERGENCY PLAN-POSITION SPECIFIC PROCEDURE REMOVE MANUAL TABLE OF CONTENTS DATE: 09/16/2003
'\\_ADD MANUAL TABLE OF CONTENTS DATE: 10/30/2003 CATEGORY: PROCEDURES TYPE: EP ID:
EP-PS-114 REPLACE:
REV:10 REPLACE:
REV:10 UPDATES FOR HARD COPY MANUALS WILL BE DISTRIBUTED WITHIN 5 DAYS IN ACCORDANCE WITH DEPARTMENT PROCEDURES.
PLEASE MAKE ALL CHANGES AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX UPON RECEIPT OF HARD COPY. FOR ELECTRONIC MANUAL USERS, ELECTRONICALLY REVIEW THE APPROPRIATE DOCUMENTS AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX.
K>
Tab6 EP-PS-1 14-6 Affected Unit Control No.
r PROTECTIVE ACTION RECOMMENDATION FORM SUSQUEHANNA STEAM ELECTRIC STATION
[1 This is a Drill 0 This is an Actual Event Preparer.
The EMERGENCY CLASSIFICATION is:
El Unusual Event 0 Alert 0 Site Area Emergency 0 General Emergency Basis: EAL #
This represents:
0 Initial Classification Escalation 0 Reduction 0 No Change in the Classification Status Emergency Action(s) implemented onsite:
O None O Local Area Evacuation O Site Accountability Bases:
O Evacuation of non-essential personnel o KI to onsite personnel o Other The PROTECTIVE ACTION RECOMMENDATION is:
I No Protective Action Recommendation Required O Evacuate 0-2 miles and Shelter 2-10 miles and advise 0 Divert Danville Drinking Water*
citizens to take KI in accordance with the State's E Relocation emergency plans.
Control of Access E Evacuate 0-10 miles and advise citizens to take KI U Contamination Controls/Decon in accordance with the State's emergency plans U Other
- Expected arrival of release at Danville: _
This represents:
Initial 0 Change 0 No Change in the Protective Action Recommendation EP-AD-000-1 10, Revision 11, Page 1 of 2
Tab6 EP-PS-1 14-6 The BASIS for the Protective Action Recommendation is:
Plant Status Status of Radioactive Release: Event-related release in progress? 0 Yes O No Total Site Release Rate Airborne Liquid
< Tech Requirements Limit O3 O
> Tech Requirements Limit O
O NOTE:
TRM Limits (gCimin): Noble Gas 1.OOE+6; Iodine 1.04E+2; Particulate 7.72 E+2 (Airbome releases)
Based on:
Effluent Monitors 0 Field Measurements El Engineering Judgement Data measured in the field confirm release rate estimations: El Yes E No O N/A Weather Conditions:
Wind Speed_
Wind Direction_
Dose Projections: 0 TEDE ; 1 rem or thyroid CDE > 5 rem at 2 miles O TEDE> 1 rem or thyroid CDE > 5rem at EPB o TEDE < 1 rem and thyroid CDE 5 rem at EPBi Other:
Approval:
Date/Time:_
Emergency Director or Recovery Manager approval required if change in Classification or Protective Action Recommendation.
RPC or DASU approval if no change in the Classification or Protective Action Recommendation.
Transmittal:
Cl Verbal 0 Electronic 0 Both Communicated To:
NAME AGENCY DATE/TIME EP-AD-000-1 10, Revision 11, Page 2 of 2
- '7 Tab 6 EP-PS-1 14-6 Control #
I EMERGENCY NOTIFICATION REPORT
- 1.. Call Status:
n THIS IS A DRILL El THIS IS AN ACTUAL EVENT
- 2.
This is:
(Communicator's Name)
My telephone number is:
at Susquehanna Steam Electric Station.
Notification time is:
(Callback telephone number)
(Time notification initiated)
- 2.
EMERGENCY CLASSIFICATION:
E UNUSUAL EVENT El ALERT D The event has been terminated.
El SITE AREA EMERGENCY El GENERAL EMERGENCY UNIT: El ONE El Two D ONE&TWO Declaration Time:
OATE:
(Time classification/
termination declared)
(Date classification/
termination declared)
THIS REPRESENTS A/AN:
El INITIAL DECLARATION El ESCALATION IN CLASSIFICATION STATUS E l No CHANGE J
- 4.
The Emergency Action Level (EAL) Number is:_
For initial declaration, static update, or escalation, provide current classificatior EA6-number only.
For significant events, or when dire6ted by the ED, RM, or EOFSS, provide a brief description.
For termination, write emergency has been terminated.
BRIEF NON-TECHNICAL DESCRIPTION OF THE EVENT:
- 5.
THERE IS: E No l AN AIRBORNE NON-ROUTINE RADIOLOGICAL RELEASE IN PROGRESS El A LIQUID
- 6.
WIND DIRECTION IS FROM:
WIND SPEED IS:
mph.
(Data from 10 meter meteorological tower, available on PICSY.)
- 7.
==
Conclusion:==
El THIS IS A DRILL El THIS IS AN ACTUAL EVENT.
APPROVED:
Time:
Date:
(Time form approved)
(Date form approved)
EP-AD-000-310, Revision 5, Page 1 of 1